Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
7,180 live and archived tenders were published on this date.
Adding a sidebar filter continues in Live Tenders while preserving this publication date.
7,180 results • Latest
Municipal Bodies
Municipal Bodies
Municipal Bodies
Municipal Bodies
Municipal Bodies
Municipal Bodies
Municipal Bodies
Municipal Bodies
Municipal Bodies
Municipal Bodies
Municipal Bodies
Municipal Bodies
NTPC Limited
Municipal Bodies
Municipal Bodies
Municipal Bodies
Municipal Bodies
NTPC Limited
Jharkhand State Forest Development Corporation Ltd
RDD-CEO-SOLAPUR
RDD-CEO-SOLAPUR
PWD
Director (ITDA)
NTPC Limited
IndianOil
Annual Maintenance Contract of 3 fire engines and 3 DG sets 2 of 750 KVA and 1 set 75 KVA of Make Cummins India Ltd at Ambabai Depot
IndianOil
Delhi Metro Rail Corporation Limited
Tender for licensing of Exclusive Outdoor Advertising Rights on Selected DMRC Civil Structures i. e. from Mayur Vihar-I to Welcome (Mayur Vihar-I, Anand Vihar, Karkarduma Court and Welcome) Metro Stations in East DMC of Line-7 (Pink Line)
Chennai Port Trust
DG,CRPF,MHA
Cleaning of water storage tank of residential and non residential building and repairing painting and cleaning of over head tank and under ground sump
Bhabha Atomic Research Centre
Integrated Defence Staff
Indira Gandhi National Open University
Allotment of Shop No.2 for grocery and general store in the IGNOU Residential Campus at Maidan Garhi, New Delhi
Corporation of Chennai
Haryana Board Corporation
Central Warehousing Corporation (CWC)
VERTICAL EXTENSION OF OFFICE BLOCK 2ND FLOOR WITH GALVANISED IRON PROFILE SHEET ROOFING AND WALL PANELLING WITH MULTI PURPOSE CEMENT BOARD AT CW THALASSERY KERALA
Public Health Engineering Department (PHED)
Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia to 75 mm HDPE PE-100, PN-6 Pipe valve specials and all fittings including all allied civil works, providing functional household tap connection (F.H.T.C) in individual households and government institution etc, complete with 03 months trial run, operation & maintenance for 06 months under Solar Dual Pump Based Piped Water Supply Scheme under Jal Jeevan Mission For Village Lalpur & Rajawar, Block - Chhuikhadan District- Rajnandgaon.
Public Health Engineering Department (PHED)
witch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village Salhewara Block Chhuikhadan District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 60 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 90/110 mm dia UPVC class 6/10 kg/sqcm Pipe, with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope connection cable including Electric connection from CSPDCL, construction of brick masonry s
Public Health Engineering Department (PHED)
from CSPDCL, construction of brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Single Village Piped Water Supply Scheme under Jal Jeevan Mission For Village Karamtara Block Khairagarh District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 100 KL capacities & staging 15 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 90/110/140/160 mm dia UPVC class 6/10 kg/sqcm Pipe & 80/100/125 mm dia G.I. Pipe , with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope connection cable including Electric connection
Public Health Engineering Department (PHED)
ng pipe, SS/Nylon wire rope connection cable including Electric connection from CSPDCL, construction of Fly ash brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Retrofitting Piped Water Supply Scheme Under Jal Jeevan Mission For Village Chircharikala & Bajrangpur Block Chhuriya District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 90 KL capacities & staging 12 mt. at Chircharikala & 40 KL capacities & staging 12 mt. at Bajrangpur including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 90/110/140 mm dia UPVC class 6/10 kg/sqcm Pipe & 80/100/150 mm dia G.I. Pipe , with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excludi
Public Health Engineering Department (PHED)
le including Electric connection from CSPDCL, construction of Fly ash brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Retrofitting Piped Water Supply Scheme Under Jal Jeevan Mission For Village Bamhni Charbhatha, Belargondi & Kumarda Block Chhuriya District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. at Bamhni Charbhatha, Belargondi & Kumarda including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 90/110 mm dia UPVC class 6/10 kg/sqcm Pipe & 80 mm dia G.I. Pipe , with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope connection cab
Public Health Engineering Department (PHED)
ing Electric connection from CSPDCL, construction of Fly ash brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Retrofitting Piped Water Supply Scheme Under Jal Jeevan Mission For Village Ranamatiya, Gidarri & Pandrapani Block Chhuriya District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. at Ranamatiya & Girdarri including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63/90/110 mm dia HDPE/UPVC class 6/10 kg/sqcm Pipe & 80 mm dia G.I. Pipe , with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope connection cable includ
Public Health Engineering Department (PHED)
nnection from CSPDCL, construction of Fly ash brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Retrofitting Piped Water Supply Scheme Under Jal Jeevan Mission For Village Halekosa , Nagarkohra & Bannawagaon Block Chhuriya District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 60 KL capacities & staging 12 mt. at Bannawagaon including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 90/140 mm dia UPVC class 6/10 kg/sqcm Pipe & 80/100/150 mm dia G.I. Pipe , with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope connection cable including Electric co
Public Health Engineering Department (PHED)
L, construction of brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village MURMUNDA, KOLIHAPURI (NAWA), Rajkatta Block Dongargarh District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 70 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 60/75/90/110 mm dia HDPE/UPVC class 6/10 kg/sqcm Pipe, 50/80 mm dia G.I. Pipe with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope connection cable including Electric connection from CSPDC
Public Health Engineering Department (PHED)
including Electric connection from CSPDCL, construction of brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village Bachherabhata, Kalyanpur Block Dongargarh District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 50 KL capacities & staging 15 mt. at Kalyanpur & Repair of Over Head Tank including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63/75/90 mm dia HDPE/UPVC class 6/10 kg/sqcm Pipe, 80 mm dia G.I. Pipe with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope connection cable
Public Health Engineering Department (PHED)
un, operation & maintenance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village Ratanbhat Block Chhuriya District- Rajnandgaon.Providing, laying, jointing, interconnection, testing and commissioning of 90 mm dia UPVC class 6/10 kg/sqcm & 50/80 mm G.I. Pipe with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope connection cable including Electric connection from CSPDCL , construction of brick masonry switch room ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator , providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial r
Public Health Engineering Department (PHED)
ncluding Electric connection from CSPDCL, construction of brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village Andi Block Dongargarh District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 75 capacities & staging 15 mt. & 70 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63/90/110/140 mm dia HDPE/UPVC class 6/10 kg/sqcm Pipe, 80 mm dia G.I. Pipe with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope connection cable i
Public Health Engineering Department (PHED)
ing pipe, SS/Nylon wire rope connection cable including Electric connection from CSPDCL, construction of brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village Rengakathera, Mudpar Block Dongargarh District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. at Mudpar & 50 KL capacities & staging 12 mt. and Repair of Over Head Tank at Rengakathera including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 90/110 mm dia UPVC class 6/10 kg/sqcm Pipe, 80 mm dia G.I. Pipe with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but exclud
Public Health Engineering Department (PHED)
brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village Pitepani Block Dongargarh District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 90 mm dia UPVC class 6/10 kg/sqcm Pipe, 80 mm dia G.I. Pipe with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope connection cable including Electric connection from CSPDCL, construction of
Public Health Engineering Department (PHED)
tion of Fly ash brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (F.H.T.C) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under Retrofitting Piped Water Supply Scheme Under Jal Jeevan Mission For Village Rampur Block Dongargaon District- Rajnandgaon.Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 90 mm dia UPVC class 6/10 kg/sqcm Pipe & 80 mm dia G.I. Pipe , with suitable joints, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficient ISI Marked required capacity three phase , 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, SS/Nylon wire rope connection cable including Electric connection from CSPDCL, construc
Across all 7,180 tenders published on this date. Statuses reflect the latest available updates; check each tender for its current deadline.
A tender can cover more than one state. Group counts may overlap.