| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L1 | Accepted-AOC being L1 | |
| 2 | L2₹5.9 L+₹73,354 (14.2%)Rejected-Finance | L2 | Rejected-Finance not being L1 |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
29 Sept 2020, 6:00 pmClosed
AGE (I) RnD Haldwani
AGE (I) RnD Haldwani po-Arjunpur 263139
REPAIR AND MAINT OF INTERNAL ELECTRIC SUPPLY, REWIRING, REPAIR and SERVICING OF CEILING FAN, GEYSER, DESERT COOLER, WATER COOLERAND ATTENDING DAY TO ADY COMPLAINTS INCL STREET LIGHTS AND OTHER MISC E/M WK AT HALDWANI
2020_MES_374596_1
AGE(I)RnD/HLD/ 17 OF 2020-2021
Open Tender
Civil Works
Item Rate
335 days
DIBER Haldwani
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) RnD Haldwani
₹14,000
Yes
11 Dec 2020
4 Sept 2020
3 Oct 2020
4 Sept 2020
29 Sept 2020
17 Sept 2020
4 Sept 2020 - 17 Sept 2020
Amount
Disconnecting, dismantling and taking out the existing unserviceable items of any description, any make and in any position and refixing new items shall be measured & paid for separately as “Supply & fixing ” under appropriate item of Sch ‘A’, disconnecting, dismantling/testing charge is deemed to be included under the unit rate quoted by the contractor for this item complete all as specified and directed. NOTE :- Applicable for Sch ‘A’ Item No.1.01 to 1.50 credit will be given separelely for demolised items.
S&F switch piano, flush type, single pole one way 5 amps complete all as specified and as directed
S&F socket out let 2 in 1, 3 pin 5A, flush type complete all as specified
S&F switch piano, flush type, single pole one way 15 amps complete all as specified and as directed
S&F socket out let 2 in 1, 5 pin 5A and 15 Amp , flush type complete all as specified
S&F ceiling rose 3 phaser VC/polycarbonate, isolated body complete all as specified
S&F lamp holder PVC/polycarbonate type with back plate suitable for batten fitting isolated body complete all as specified
S&F Ceiling Fan Regulator deluxe 240V 50 Hz step type.
S&F Bell ding dong L&T/Havells/CG/Anchor/
S&F Capacitor for ceiling fan 2.5 MFD copper wired Make:- L&T/Havells/CG/Anchor/
S&F Capacitor for ceiling fan 4 MFD copper wired Make:- L&T/Havells/CG/Anchor/
S&F Top plug 3 pinl 6 Amp Make:- L&T/Havells/CG/Anchor/
S&F Top plug 3 pinl 16 Amp Make:- L&T/Havells/CG/Anchor/
S&F Modular switch 1 way 6 Amp 1 Module complete all as specified and directed. Make:- L&T/SSK/Havells/CG/Anchor.
S&F modular socket 6 amp-2/3 pin combined 2 module complete all as specified and directed Make:- L&T/SSK/Havells/CG/Anchor.
S&F Modular switch 1 way 16 Amp 1 Module complete all as specified and directed. Make:- L&T/SSK/Havells/CG/Anchor.
S&F Modular combined plate 1module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular combined plate 2module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular combined plate 3module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular combined plate 4module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular combined plate 6module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular combined plate 8module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular combined plate 9module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular combined plate 12module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular combined plate 16module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular combined plate 18module Make:- L&T/SSK/Havells/CG/Cona.
S&F Flash metal GI box 1/2module Make:- L&Tequivalent
S&F Flash metal GI box 3module Make:- L&T/SSK/Havells/CG/Cona.
S&F Flash metal GI box 4module Make:- L&T/SSK/Havells/CG/Cona.
S&F Flash metal GI box 6module Make:- L&T/SSK/Havells/CG/Cona.
S&F Metal plug Top 32 Amp 3 pin Make:- L&T and equivalent.
S&F Metal plog socket 32 Amp 3 pin Make:- L&T and equivalent .
S&F MCB single pole, 6 to 32 Amps (`C’ series ) having current rating 10 KA complete all as S&F specified and directed.Make : L&T, legrand,havells
ditto but MCB single pole, 40 Amps
ditto but MCB single pole, 63 Amps
ditto but MCB doule pole, 6 to 32 Amps
ditto but MCB double pole 40 Amps
ditto but MCB double pole 63 Amps
ditto but MCB triple pole 40 Amps
ditto but MCB triple pole 63 Amps
ditto but MCB four pole 40 Amps
ditto but MCB four pole 63 Amps
S&F Copper conductor 1.5 sqmm Make:- L&T/Havells/Plaza/Anchor
S&F Copper conductor 2.5 sqmm Make:- L&T/Havells/Plaza/Anchor
S&F Copper conductor 4 sqmm Make:- L&T/Havells/Plaza/Anchor
S&F Copper conductor 6 sqmm Make:- L&T/Havells/Plaza/Anchor
S&F Copper conductor 2.5 sqmm 3 core rounded Make:- L&T/Havells/Plaza/Anchor
S&F Copper conductor Flexible twin twisted Make:- L&T/Havells/Plaza/Anchor
S&F LED adore 9 watt 3 star lamp Crompton/Havells/C&S/Philips
S&F LED adore 15 watt 3 star lamp Crompton/Havells/C&S/Philips
S&F LED adore 20 watt 3 star lamp Crompton/Havells/C&S/Philips
Disconnecting, dismantling and taking out the existing unserviceable items of any description, any make and in any position and refixing new items issued under sch 'B' , disconnecting, dismantling, fixing/ testing charge is deemed to be included under the unit rate quoted by the contractor for this item complete all as specified and directed. NOTE :- Applicable for Sch ‘A’ Item No. 2.01 to 2.19 old unserviceable items will be the property of contractor and necessary credit will be recovered except of items No. 2.19 i.e. old unserviceable energy meter will diposeted at MES yard, this perticular item will the property of department and further disposal action will carried out.
Fixing only MCB TP 10 KA 6 to 32 Amps 415v any make complete all as specified and directed. Items will issued under Sch 'B'
Fixing only MCB TPN 10 KA 6 to 32 Amps 415v any make complete all as specified and directed. Items will issued under Sch 'B'
Fixing only in repair Modular Celieng Fan Regulator ,120 W of 2 module Items will issued under Sch 'B'
Fixing only isolator 40Amp DP Amps 415v any make complete all as specified and directed. Items will issued under Sch 'B'
Fixing only isolator 63 Amp TPN any make complete all as specified and directed. Items will issued under Sch 'B'
Fixing only isolator/MCB 63 Amp DP/SPN any make complete all as specified and directed. Items will issued under Sch 'B'
Fixing only capacitor 10 MFD any make complete all as specified and directed. Items will issued under Sch 'B'
Fixing only switch Bell push Items will issued under Sch 'B'
Fixing only switch 2 way 6 Amp modular, complete all as specified and as directed
Fixing only switch 2 way 6 Amp non modular, complete all as specified and as directed
Fixing only in repair Modular socket 1 way 16 Amp 2 Module complete all as specified and directed. Items will issued under Sch 'B'
Fixing only in repair Modular bell push 6 Amp 1 module Items will issued under Sch 'B'
Fixing only LED FTL fitting any make any type complete all as specified and as directed
Fixing only MCB 30 to 63 Amp SP any make complete all as specified and directed. Items will issued under Sch 'B'
Fixing only isolator 32 to 200 Amps any type and make complete all as specified and directed. Items will issued under Sch 'B'
Fixing, grouting, connecting with existing point metal plug and socket 20 Amps 415v any make complete all as specified and directed. Items will issued under Sch 'B'
Fixing only energy meter electronic single phase 10-45 Amps 415v any make complete all as specified and directed. Items will issued under Sch 'B'
Disconnecting, dismantling and taking out the non-functional Air conditioner window type of any description, any make and in any position, 1.5 TR/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with using caustic soda/detergent powder solution, checking serviceability of wiring & parts, painting the bottom with one coat of black synthetic enameled paint, brazing, reassembling and testing of the AC and refixing in existing position complete all as specified and directed
Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete all as specified and directed. NOTE :- (Applicable for Sch ‘A’ Item No.3 & 4) (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply & fixing ” under appropriate item of Sch ‘A’. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item
Disconnecting and taking out defective / nonfunctional air filter and Supply & fixing Air filter nylon type suitable for Split A/C complete all as specified and directed. Make –carrier, Blue star,Haier, Voltas etc
Disconnecting and taking out defective / nonfunctional air filter and Supply & fixing Air filter nylon type suitable for window A/C complete all as specified and directed. Make –Carrier, Blue star,Haier, Voltas etc
Disconnecting and taking out defective / nonfunctional outdoor Air filter and Supply & fixing air filter suitable for window A/C complete all as specified and directed. Make –carrier, Blue star,Haier, Voltas etc
Disconnecting and taking out defective / nonfunctional outdoor fan motor and Supply & fixing fan motor suitable for window A/C complete all as specified and directed. Make –carrier
Disconnecting and taking out defective / nonfunctional fan motor and Supply & fixing fan motor suitable for window A/C complete all as specified and directed. Make –carrier
Disconnecting and taking out existing defective / unserviceable remote control assembly with PCB of any description and in any position of any type of split AC & Supplying & fixing new remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .(Make : Carrier/Hitachi/LG )
Disconnecting and taking out defective / nonfunctional capacitor 60MFD/4.0MFDand Supply & fixing capacitor suitable for Split A/C/window A/C complete all as specified and directed.
Disconnecting and taking out defective / nonfunctional relay contactor and Supply & fixing relay contactor suitable for Split A/C complete all as specified and directed.
Taking out defective sealed unit compressor of window type AC of capacity 2.0 TR of any make and transportation to company for repair and thereafter fixing back the repaired compressor of original make in the existing AC, including welding, brazing of gas pipe line, vacuum pressure for leakage & testing with charging of Refrigerant Gas and testing & commissioning of AC complete all as specified and directed.
All as per item No.12 here in above but compressor of 1.5 TR capacity AC of any make complete all as specified and directed.Note:- Refrigerant Gas required for charging of compressor shall be measured separately under respective item of this Schedule.
Supply & charging of refrigerant Gas R-22 Mono chloro difluoro methane (CHCLF2) to make up the required pressure complete all as specified and directed.
Supply & fix of remote controll for window/split A/C complete all as specified and directed.
Supply & fix of drain pipe for window/split A/C standard size of 3 meter complete all as specified and directed. Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for respective Sch ‘A’ item here in above.
Disconnecting, dismantling and taking out the non-functional voltage stabilizer for General servicing and minor repairs AC 230 volts Single Phase 3 to 5 KVA cap. of any make by checking, tightening of electrical connection, replacement of all missing/worn out screws, indicating lamps, checking of electronic circuits to make it functional including replacement of minor defective parts complete all as specified and directed. NOTE :-The replacement of defective / nonfunctional parts shall be measured & paid for separately under appropriate item of Sch ‘A’
Supply & fixing transformer copper wound of voltage stabilizer AC, Single Phase, 230 volts of capacity 5 KVA of approved make complete all as specified and directed. Note :- Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for respective Sch ‘A’ item here in above. .
All as per Item No 18.01 here in above but of capacity 4 KVA complete all as specified and directed.
Circuit plate
Relay
volt meter
Taking out & removing old burnt-out windings of Desert cooler fan motor of any description and servicing/rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal) including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site and re- assembling the complete, connecting and testing on full load to the entire satisfaction of Engineer-in-charge.
Supply new wood wool pads best quality of required size as approved (three in each on desert cooler) complete all as specified and directed.
Supply of submersible pump for Desert cooler 230 volts, 45 watt, 1400 RPM, with ball bearings complete all as specified and directed (Make : Crompton / AUE / Khaitan/ Bajaj )
Supply only ball bearing req size (Make SKF/NRB/NBC)
Supply only gun metal bushes of any description and size to suit existing motor shaft including grinding & polishing of fan motor shaft to required shape/size.
Disconnecting and taking down the existing Geyser of any description and any capacity (25 / 50 Ltrs) and any position from the existing location and Dismantling the Geyser of any capacity and of any description material and labour for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet , overflow Geyser element, thermostat , ‘U’ assembly etc. with brush, cleaning rod, and using de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning, Fixing and installation of Geyser in position and testing to the entire satisfaction of Engineer-in-Charge. Note :- Spare parts if any requires replacement shall be measured and paid for separately .Supply only the following new parts suitable for geyser of capacity 25 /50 ltrs of 2Kw &1.5Kw. Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for Sch ‘A’ item No. 19 here in above.
Supply only ‘U’ assembly SS of 25 Ltr cap any description and in any position from Geyser and supply and fixing new ‘U” assembly to match with the existing system complete all as specified and directed. Make – Recold / Bajaj,/ Daspass
Supply only Indicating lamp of size /shape as per existing suitable for 230 Volts AC supply. complete all as specified and directed
Supply only Geyser thermostate of size /shape as per suitable for 25 ltrs & 50 ltr cap heavy duty copper material used 230 Volts AC supply. complete all as specified and directed
Supply only geyser heating element of 2 Kw cap heavy duty copper material used and round cup and triangle cup shape with rubber washer .complete all as specified and directed
Supply only Geyser thermal cutout of size /shape as per suitable for 25 ltrs & 50 ltr cap heavy duty copper material used 230 Volts AC supply. complete all as specified and directed
Disconnecting , taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans and air circulating fans etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations/Tech buildings) for repairs / servicing / overhauling / painting / numbering etc, dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction complete all as specified and directed. Scope of work shall also included replacement of ceiling fan issuedunder sch 'B' (including notes mentioned here in below )Note for item 20here in before : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Remetaling of motor shaft, polishing and grinding and making to standard size to matching with GM Bush shall be measured and paid for separately under appropriate item of Sch ‘A’
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal) as apv. by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engineer-in-charge for the following Fans:-
Rewinding of motor of ceiling fans 1200/1400 mm sweep
Rewinding of motor of exhaust fans of 250 mm sweep.
Rewinding of motor of exhaust fans of 300 mm sweep.
Rewinding of motor of exhaust fans of 450 mm sweep.
Supply only the following new parts suitable for the ceiling/ exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep Note :- Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for respective Sch ‘A’ item No.22 here in above.
Supplying only ball bearing No 6200 (Make SKF/NRB/NBC)
Supplying only ball bearing No 6201 (Make SKF/NRB/NBC)
Supply only gun metal bushes of any description and size to suit existing motor shaft including grinding & polishing of fan motor shaft to required shape/size.
Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for ceiling fans of any descriptions & of 1400/1200 mm sweep.
Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fan fans of any descriptions & of 300/250 mm sweep.
Supply only MS nuts & bolts with one hole washer & lock pin of suitable size for hanging assembly complete.
Taking out the exesting loose fitted, hang and defective due to locking arrangement and M&L for repair / replacement of locking arrangement,brazing,welding,screwing not & bolts,painting,re fix the existing serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the SPN/TPN DB, making necessary adjustment and proper alignment of items in position, connecting to existing electric sources and testing at site to the entire satisfaction complete all as specified and directed.
Taking down unserviceable street light and m&l for carry out repair and refix the same of the different spares/components /parts of street light/gate light/garden light/post top lantern light fittings,of any wattage/capacity and any description and fixed in any position complete all as specified and directed.(i) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site.(ii) Required screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item.
M&L for applying one coat of synthetic enamel paint on old painted steel suraface ie. Street light poles of height upto 09 mtrs apprx and post top lantern poles of height upto 03 mtrs apprx as existing colors incl numbering of poles as exizting numbers incl preaparation of old surface complete all as specified and directed.
Dismantling of existing unsevicable of XLPE insulated armoured cable and any type and any size complet all as sepcified and directed
Supply and lay XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 35 x3.5 core complete all as specified.
Ditto but size 10 sqmm 2 core
Excavation in trenches not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide in hard/dense soil for laying GI tubing completed all as specified.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cable etc are laid, jointed and tested completed all as specified complete all as specified and directed .
Removal of surplus excavated spoil not exceeding 50 mtr distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified
M&L for old size sub class ‘B’ bricks, kiln burnt, as in cable protection laid flat with axis of brick perpendicular to the axis of the cable complete all as specified
Supply and laying GI pipe of 50mm dia bore light grade for cable protection etc laid in trenches/pole post etc. complete all as specified and directed
Ditto but of 80mm dia.
Disconnecting, dismantling and taking out the existing unserviceable items of any description, any make and in any position and refixing new supply & fix aluminium 1100 volt grade heavy duty cable PVC insulated aluminium conductor service connection cable twin core flat cable stranded conductor 10sqmm Make: plaza /Havells/Kalinga/ polycab
M& L for supply instalation, testing, commisioning of fire alarm Main control box of 12 zone, suitable for 99 ditector up to 200 ditector and modules in replacement of existing unserviceable fire control panel incl Disconnecting, dismantling and taking out existing unserviceable fire control panel to the entire satisfaction of Engineer-in-charge. Make: Agni/Ravel
M& L for supply instalation, testing, commisioning of fire alarm sub panel controll box of 2 zone and modules in replacement of existing unserviceable fire alarm sub panel controll box of 2 zone incl disconnecting, dismantling and taking out existing unserviceable fire control sub panel to the entire satisfaction of Engineer-in-charge. Make: Agni/Ravel
M& L for supply instalation, testing, commisioning of fire alarm hooter/sounder built in ABS housing / MS housing (12 volt dc) connected with main controll pannel in replacement of existing unserviceable fire alarm hooter/sounder incl disconnecting, dismantling and taking out existing unserviceable fire alarm hooter/sounder to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
M& L for supply instalation, testing, commisioning of fire alarm manual call point (MCP box) in replacement of existing unserviceable fire alarm manual call point incl Disconnecting, dismantling and taking out existing unserviceable fire alarm manual call point to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
M& L for supply instalation, testing, commisioning of smoke detector in replacement of existing unserviceable smoke detector incl Disconnecting, dismantling and taking out existing unserviceable smoke detector to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
M& L for supply instalation, testing, commisioning of fire alarm response indicator in replacement of existing unserviceable response indicator incl Disconnecting, dismantling and taking out existing unserviceable fire remote indicator to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
M& L for supply instalation, testing, commisioning of fire alarm industrial sirens 1/2 km range electronic type in replacement of existing unserviceable industrial sirens incl Disconnecting, dismantling and taking out existing unserviceable fire remote indicator to the entire satisfaction of Engineer-in-charge Make: Agni/Ravel
Note : (i) The entire work will run for 11 months as indicated in the tender documents. Completion before time shall not be entertained by the accepting officer. Site for the entire work shall be given to the Contractor in piecemeal manner and rates quoted by the Contractor shall be included in the respective item of BOQ. No extra payment shall be admissible to the contractor on this account. Tenderers may be noted that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract.
Amit Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .