| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹63.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹68.2 L+₹3.6 L (5.54%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance Other then lowest bidder | |
| 3 | L3₹74.7 L+₹10.1 L (15.7%)Rejected-Finance | L3 | Rejected-Finance Other then lowest bidder | |
| 4 | L4₹78.8 L+₹14.2 L (21.9%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L4 | Rejected-Finance Other then lowest bidder |
Tender Value
₹74.8 L
EMD Value
₹1.4 L
Closing Date
20 Mar 2024, 6:00 pmClosed
Col Manish Dhaka CWE
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
SPECIAL REPAIR TO BLDG ROOF TREATMENT AND ALLIED WORKS SERVICES TO C AND D AFSR UNIT AT HQ SWAC U
2024_MES_642688_1
82192/CHL/E8
Open Tender
Civil Works
Works
270 days
Gandhinagar
As per Tender Documents
7 documents required · 7 mandatory
₹1,000
GE (AF) Chiloda
₹1.4 L
19 Apr 2024
17 Feb 2024
27 Mar 2024
17 Feb 2024
20 Mar 2024
6 Mar 2024
18 Feb 2024 - 25 Feb 2024
Amount
Taking down chowkats or frames with shutters (without taking off shutters from frames) size exc 1.5 Sqm & n.exc 4.00 Sqm each.
Dismantling floor, hearth or wall tilling including uding cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
Taking down cement or cement lime plaster any description including racking out joints, hacking for key, scrubbing down with water etc.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, iron frame, concrete or brick surrounds, glazed with putty or fixed with beads exc 1.5 sqm.
Taking up or down steel /UPVC water tubing and connections,15 mm bore complete all as specified
Taking up or down steel /UPVC water tubing and connections,20 mm bore complete all as specified
Taking up or down steel /UPVC water tubing and connections,25 mm bore complete all as specified
Dismantling water tanks 1000 but n.exc 2000 Litres capacity complete all as specified and directed
Demolition of brickwork or stone/ boulder masonry, built in cement mortarcomplete all as specified and directed.
Demolition of cement concrete of (unreinforced) any description and in any position not otherwise specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling Plain or corrugated steel/ Fibre translucent sheeting, any gauge, thickness, including uding Nainital or similar pattern roof coverings complete all as specified and directed
Dismantling of ceiling board/false ceiling any Size and thickness all as specified and directed.
Demolition and breaking up 200mm dia salt glazed stone ware drain pipe including uding PCC bed, PCC packing under hunching against the sides of bed complete all as specified and directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and getting out in soft soil complete all as specified and directed
Excavating in trenches, n exc 1.5 m wide for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and exc 1.5 m and upto 3.0m deep and getting out in soft soil complete all as specified and directed.
Returning filling in including uding spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft and loose soil complete all as specified and directed.
Removing excavated material n exc 50 m and depositing where directed at level not n exc. 1.5 m above the starting point complete all as specified and directed
M&L ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including uding drilling and plugging holes etc. in apron complete all as specified and directed
M&L ATT to soil under existing floors using emulsion @ one litre per hole, 300mm apart including uding drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed
M&L ATT at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed.
M&L PCC 1:2:4type B1 using 20mm graded stone aggregate as in surface channel, flooring etc. complete all as specified and directed
M&L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in coping or benching of manhole etc including uding necessary formworks complete all as specified and directed
M&L Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls and set in cement mortar 1:4 including necessary form work complete all as specified and directed
Supply only liquid water proofing compound.
M&L Brick work with sub class 'B', old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed
M&L Granite 18 to 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified.
S&F 1st class hard wood plain solid strength chowkats frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint complete all as specified and directed.
S&F 30mm thick flush door shutter, solid core construction with block board core and ply wood face panels, commercial type on both faces complete all as specified and directed.
M&L 30 mm thick 1st class hard wood glazed and skeleton shutters open rebated and prepared to receive glass divided into squares rebated sash bars any numbers, edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass, sizes of members as specified in SSR Part-I section 8 clause 8.24 (a) supply and fixed to chowkat, complete all as specified.
S&F 30mm thick factory made solid panel PVC door shutter (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed..
S&F Factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC Sheet reinforced with MS square tube complete all as specified and directed..
S&F Aluminium anodized barrel tower bolt of extruded section, length of bolt 150mm complete all as specified and directed..
S&F 100mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed..
S&F 150mm size aluminium handles, cast type anodised complete all as specified and directed..
S&F 20mm dia, brass chromium plated tubular towel rail, D type, 60cm long between flanges complete as in repairs all as specified and directed.
S&F Door closer aliminium (die cast) body hydraulically regulated designation No 3 universal type suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete as in repairs all as specified and directed..
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete as in repairs all as specified and directed.
M&L Mild steel bars 10mm dia and over, cut to length, bent to shape required, including uding cranking, bending spirally for hooping for columns, hooking ends and binding with and including uding mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
M&L Anodised aluminium snap grid size 605x605mm frame work for false ceiling complete all as specified.
S&F 0.50mm thick pre-painted galvalume aluminium zink coating GI based corrugated steel sheet of colour having tensile strength of 550Mpa as in roof covering fixed with self tapping screw all as specified and as directed.
S&F Gypsum Board 605x605x 12mm thick in ceiling fixed with screw as per manufacturer's instructions complete all as specified.
M&L Glazed ceramic coloured tiles in vertical surfaces 300x450x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 SQM but not exceeding 0.11 SQM, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
M&L Vitrified Ceramic tiles dark shade 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 SQM, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match premium quality as in floor etc complete all as specified.
M&L Vitrified Ceramic tiles dark shade 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 SQM on vertical surfaces/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified complete all as specified
M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 to receive tiles etc on vertical surfaces of walls complete all as specified
M&L Rendering 10mm thick plaster in CM 1:6 on fair faces of brick work or concrete surfaces of walls finished even & smooth with out using extra cement complete all as specified.
M&L 10mm thick cement plaster in CM 1:3 as in ceiling finished even and smooth without using extra cement complete all as specified .
M & L Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished even & fair with WPC @3% without using extra cement work complete all as specified .
M&L 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified.
M&L Preparation of old surfaces of ceiling and applying one coat of distemper oil emulsion complete all as specified.
M&L Preparation of old surfaces of walls and applying one coat of distemper oil emulsion complete all as specified..
M&L Preparation of old surfaces of walls and applying two coats of distemper oil emulsion complete all as specified.
M&L Preparation of old surfaces of walls and applying one coat of cement based paint complete all as specified..
M & L Preparation new surface of wall and applying two coats of oil emulsion distemper over a coat of primer with two coat of chalk whiting smooth finish surface complete all as specified.
M & L Preparation new surface of ceiling and applying two coats of oil emulsion distemper over a coat of chalk whiting complete all as specified.
M&L Preparation of new surfaces of walls and applying two coats of cement based paint complete all as specified..
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sq.m in each pane complete all as specified.
M&L Preparation of old surfaces of wall/chequered tiles floor and applying one coat of exterior emulsion paint complete all as specified
M&L Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified.
S&F 25 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors including uding 'T', elbow etc. connect with any type of pipe complete all as specified
S&F 15 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors including uding 'T', elbow etc. Connect with any type of pipe complete all as specified
S&F 20 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors including uding 'T', elbow etc. Connect with any type of pipe complete all as specified
S&F Rotational moulded water storage tank 1000 Ltr capacity double layer (cylindrical/vertical with closed top) hoisted and fixed in position complete all as specified as directed.
S&F Pillar taps fancy type cast copper alloy, with capstan heads, chromium plated screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed to 15mm bore pipe complete as in repairs all as specified.
S & F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with MS screw & bolts in repairs complete as in repairs all as specified..
S&F 25 mm UPVC valve for any type of pipe and fixed complete as in repairs all as specified..
S&F Vitreous China squatting pan, orissa pattern of size 580x440mm, white with integral foot rest including connection to trap & flushing pipe complete as in repairs all as specified.
S & F Vitreous china wash down water closet pan (pedestal pattern) p or s type (excluding fixing bolts, flushing cistern and flush pipe) complete as in repairs all as specified.
S&F 10 litres capacity PVC valveless symphonic action type, flushing cistern, low level, white, with inlet, ball valve float handle including brackets complete as in repairs all as specified.
S & F Vitreous china wash hand basin, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete as in repairs all as specified.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete as in repairs all as specified
S&F 40 mm size waste pipe for wash hand basin / urinal / sink complete as in repairs all as specified.
S & F Bib taps fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed to 15mm bore pipe complete as in repairs all as specified
S&F 15 mm CP Bib cock 2 way with wall flange and single knobs with all fittings and as specified complete as in repairs all as specified.
S&F Stop valves fancy type cast copper alloy, screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed to15mm bore pipe complete as in repairs all as specified.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete as in repairs all as specified.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified
S&F 75 mm bore PVC (SWR) Vent cowl any radius complete all as specified
S&F 110 mm bore PVC (SWR) junction single (single "T") equal or unequal complete all as specified
M&L Concrete bed to 200mm dia drain pipes with PCC 1:4:8 type D-2 using 40mm graded including packing under, and haunching & packing against the sides of pipes after they are laid and tested complete all as specified
M&L 200 mm dia SGSW drain pipe ,Class ‘A’ (ISI marked) of approved make laid in trenches jointed in CM 1:1 complete all as specified
S & F Soap dish SS, fixed to plugs with chromium plated brass screws complete in repairs all as specified
S&F Aluminium ventilator powder coated in two parts, in first parts stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with MS screw & bolts with fixed aluminium section and in second part ventilator fixed and flip type with aluminium section 20558,14019 (Jindal) with rubber gasket beading and locking arrangement etc complete all as specified and as directed. Note - Glazing/ wire mesh shall be included in the unit rate.
S&F CP Overhead rain shower - ABS type Square 180x180mm complete with all fittings complete in repairs all as specified
S&F CP Health Faucet ABS body (Push type) with wall hook and 1.0 mtr SS Braded rubber hose pipe complete in repairs all as specified
Dismantling/removal of old membrane, geotextile etc materials of any description and removal material out of MOD land/sites as specified and directed
M&L Waterproofing treatment over roof/parapet for cleaning & surface preparation and making surface dust free crack more than 0.5 mm then opening of crack in V grove and filling with epoxy mortar and 01 coat of Asian paints epoxy primer (Resin + Hardner) 02 coats of Asian paints ultron hybrid polyurea (cunsumption 01 Kg per 01 Sqm) complete all as specified and directed by Engr-in-charge. Note :- Cleaning & surface preparation shall be done by the authorised applicator only.
M&L Welding window clip at window frame to hold the window glass pane complete all as specified.
S&F Aluminium powder coated (Three track) sliding windows with frame of size 92x31.75x1.50mm and shutters of size 42 x 18x 1.50 mm with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete and stainless steel wire mesh 0.36 mm nominal dia of wire with 1.40 mm average width of aperture and fixed with stainless steel wire staples and fixing 5 mm thick glass with necessary rubber beading, gasket etc all as specified and as directed by Engr-in-charge . Note - Glazing/ wire mesh shall be included in the unit rate.
S&F Aluminium windows ( Double track) / ventilator powder coated of section 85.00mm x 31.75 mm x 1.50 mm thick shutter of section 19 x 40 x 1.5 mm with rubber gasket beading and locking arrangement etc complete all as specified and as directed. Note - Glazing/ wire mesh shall be included in the unit rate.
S&F Aluminium powder coated grill 6 mm thick fixed to walls with and including 'H' of 'F' aluminium channel of size 38 mm x 12 mm x 1.50 mm complete all as specified.
M&L Repair to RCC members such as RCC beam, slab, column or equivalent including cleaning of reinforcement with using Rusticide SS" or equivalent rust cleaner with wire brush after that applying of two coats of slurry made out of "Polyalk Fixoprime" /IP NET RB and cement made in proportion of 1:1.5 on exposed reinforcement surface, then applying Polymer Modified cement mortar in proportion 1:5:15 (Polyalk EP:Cement: Washed Quartz sand) including trowelling, curing and finishing/ making surface rough for plastering or equivalent for thickness 0-25mm complete all as specified.
M&L Drilling and fixing Teflon nozzles in RC member, including Drilling Holes: Drilling 12mm dia, 50 to 75mm deep holes in structural members at the intervals of 350mm in staggered manner or as directed by the consultant in RC Structural element. Cleaning of holes: Clean the holes by air blower prior to fixing nozzles; Insert 12mm dia teflon nozzles in cleaned holes. External end of nozzle to be machine to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min 12 hrs. Cutting of Nozzles: cut the nozzles by chisel after completion of grouting without damaging structural element complete all as specified.
M&L Grouting injecting low viscosity high molecular weight thermoset polymer MONOPLO by pressure and using injector with accessories till nozzle refused to accept the grout, including Mixing of materials : mixing materials components part ‘a’ and part ‘b’ in required quantities as per manufacturing instruction by weigh batching Grouting : Fill the grouting gun with monopole. Maintain desired pressure in the gun by the air compressor maintain the pressure at exit (3 to4 kg/Cm2 ) by monitoring pressure element still its refusal. Seal the nozzle with EPCO 1010 putty after the refusal. Monitoring leakage through other nozzles while grouting and seal them as per [email protected] kg/nozzle complete all as specified.
Taking down carefully copper/ aluminium point wiring (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, sockets light fittings etc , removing material to store for keeping in safe custody or for taking credit , and making good disturbed surface of walls, floors, etc.complete all as specified.
M&L Point wiring with 1.5 Sqmm single core PVC insulated unsheathed multi stranded copper conductor FRLS cable 1100V grade drawn through and including PVC concealed conduit with accessories like bends tees, junction boxes etc fixed recessed in wall or ceiling etc including uding 1.5 Sqmm single core PVC insulated but unsheathed multistrandard copper conductor FRLS cable 1100V grade as earth continuity wire including modular sunken type pressed steel terminal boxes of size with 3mm thick bakelite steel white/coloured top cover for :-
(a) One light point controlled by one switch complete all as specified
(b) One fan point controlled by one switch complete all as specified
(c) One 3 pin socket out let 5 Amps on the independent board complete all as specified.
(d) One 3 Pin socket out let 5 Amps on the same board complete all as specified.
Ditto- all as above item No.100 but with cable of size 2.5 Sq mm PVC insulated on independent board for power plug 15 Amps complete all as specified.
S&F Modular switch 1 way 6A, 1 module one way 5 Amp 240 Volts complete all as specified and directed.
S&F Modular switch 16A 1 module complete all as specified and directed complete all as specified and directed
S&F Modular Socket, 6/10A - 2/3 pin combined 2 modules,240 Volt. complete all as specified and directed
S&F Modular Socket15/16A - 2/3 pin combined 2 module complete all as specified and directed
S&F Fan step regulator 120W 2 Module complete all as specified and directed.
S&F Ceiling rose surface bakelite three terminal/ poly carbonate isolated body 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed
M&L Sub main wiring complete with two run of 6 Sqmm single core, PVC insulated but unsheathed, multistranded copper conductor FRLS 1100 Volts grade cable drawn through in and including non metallic, rigid, PVC heavy duty surface conduit/casing capping (ISI marked) with wall thickness not less than 1.8mm complete with all accessories like bends, tees, junction boxes fixed on wall, ceiling and including sunken type pressed steel terminal boxes with 3mm thick bakelite white/coloured (as approved) top cover including 6 Sqmm single core PVC insulated but unsheathed multistandard copper conductor FRLS 1100 Volts grade cable as earth continuity wire and connected to earth dolly complete as in repairs all as specified. Note :- Two run of 6 Sqmm cable including one run of earth wire and PVC conduit and its accessories shall be measured and paid as one length.
M&L Sub main wiring complete with PVC insulated cable of single core 4 Sq mm (FRLS) 1100 volts grade with multi stranded copper conductor for drawn through and including PVC casing -capping with accessories including 4.0 Sq mm unsheathed multi stranded copper conductor as on earth wire complete as in repairs all as specified. Note :- Two runs of single core cable with one run of earth continuity cable including PVC casing -capping and its accessories will be measured and paid as one unit
M&L Concealed sub main wiring complete with PVC insulated FRLS cable of single core 2.5 Sqmm 1100 volts grade with multi standard copper conductor for drawn through and including conducting PVC casing capping/ Conduit with accessories including 2.5 Sqmm unsheathed multi standard FRLS copper conductor as earth wire. Note: Two runs of cable and one run of conduit & earth wire shall be measured as one run length.
S&F Sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links ( without MCB's) SPN/ TPN complete as in repairs all as specified.
S&F Sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links ( without MCB's) 08 ways SPN complete as in repairs all as specified.
S&F Sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links ( without MCB's) 04 ways SPN complete as in repairs all as specified
S&F MCB, single pole 240 volts 6 to 32 Amps capacity B series in DB's complete all as specified and directed
S&F MCB, single pole and neutral link 240 volts 6 to 32 Amps capacity B series in DB's complete all as specified and directed
S&F LED tube light fittings 1x9Watts, 230 volts surface and wall mounted LED type and including connection up with twin core twisted flexible copper conductor cable of size 1.5 sqmm complete as in repairs all as specified
S&F LED tube light fittings 1x22Watts, 230 volts surface and wall mounted LED type and including connection up with twin core twisted flexible copper conductor cable of size 1.5 sqmm complete as in repairs all as specified
Taking down ceiling fan/cabin fan and dismantling fan blade, dismantling electric connection, removing capacitor, checking of bearings/bushes, cleaning the fan blades with clear water, scrapping the fan blades, placing the bearing, bush, capacitor, rewinding complete reassembling the ceiling fan complete after greasing, oiling, two coat of superior enamelled paint, testing the same & making the fan serviceable of any sweep and re-hanging and connecting up to the ceiling rose complete all as specified.
S&F Exhaust fan 300 mm sweep 240 V AC single phase energy efficient complete with lovers and shutters of any sweep including provision of flexible three core copper conductor cable of 23/0.0076 up to ceiling rose and grouting 04 Nos full threaded bolts and nuts etc all as specified Note: All necessary arrangement such as wooden frame/cut in existing window frame or making hole in existing wall and making the disturbed surfaces as per existing are included in quoted rate.
S&F Vertical load line TPN DB double door enclosure type (TPN) 6 way 415 volts with IP 65 protection complete, including incoming: (a) MCCB of 160 amps 4 pole 25 KA, 50 Hz outgoing: (a) 40 Amp MCB TP 10 KA, C- series-06 Nos including grouting on wall with nut and bolt properly complete and as directed by Engr-In-Charge.
M&L Earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6mm thick buried directly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron or steel earth lead wire 4 mm dia upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel providing alternate layer of charcoal dust and salt all as shown in electrical plate No.3 of SSR Part-1 and connected to test point including necessary excavation/ earth work in any type of soil/rock strata, Construction of earth pit with PCC 1:2:4 type B1 as per electrical plate No 3 of SSR-I including CI frame and CI cover 10mm thick of size 300mmx300mm funnel with wire mesh and watering pipe 20 mm dia bore (medium grade), PCC pit with 50mm thick PCC cover etc. including testing on completing including GI protection pipe 15mm dia medium grade for earthing lead complete all as specified and directed Note :(i) Earth strip and protection pipe up 7.5 Mtr is deemed to be included with unit rate of item.
Supply and laying 80 mm bore GI tubing medium grade including all type of fittings and accessories of size laid in trenches complete all as specified Note : Excavation earth work shall be measured and paid under relevant item
Supply and laying 50 mm bore GI tubing medium grade including all type of fittings and accessories of size laid in trenches complete all as specified Note : Excavation earth work shall be measured and paid under relevant item
Supply and laying 25 mm bore GI tubing medium grade including all type of fittings and accessories of size laid in trenches complete all as specified Note : Excavation earth work shall be measured and paid under relevant item
S&F Sluice valve class PN 1.6 of size 80 mm dia , screwed type complete all as specified.
S&F Gate valve of size 50 mm dia , screwed type complete all as specified
S&F Gate valve of size 25 mm dia , screwed type complete all as specified
M&L Valve chamber type ‘C’ of inner size 900mm x 600mm x 1000mm with brick masonry built in CM (1:6) with MS cover 1.60mm thick & locking arrangement including excavation & earth work in any type of soil, PCC(1:4:8) type D-2 size for foundation, PCC coping in cement concrete (1:2:4) type BI, plastering 10mm thick in CM mortar (1:4) and applying one coat or red oxide primer & two coats of synthetic enamel paint on all steel surfaces all as specified and directed complete and shown on drawing No. CEAA/TD/57 sheet No.1/1 complete all as specified
VIJAY CONSTRUCTION CO
M/s Matadeen Ramchandra Agarwal
ARTI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .