Superintending Engineer
Electricity Distribution Circle, Rudrapur
Electrification work in P.M. Awas Yojna at Shyamnagar Gadarpur under 33/11 KV S/s Chinimill under EDD-II Rudrapur
2025_UPCL3_87663_1
EDC(USN)30/2025-26
Open Tender
Electrical Works
Turn-key
180 days
Gadarpur
Pl. refer tender documents
4 documents required · 4 mandatory
₹5,900
EE ETD Rudrapur
₹1.1 L
23 Dec 2025
29 Sept 2025
24 Oct 2025
29 Sept 2025
24 Oct 2025
29 Sept 2025
Amount
Annexure-A (LABOUR CHARGES)
Earthing of distribution transformer including digging of pit of size 2.5 Mtr depth and make hole of size 150 mm. Placing of earthing electrode (to be supplied by contractor), connecting the same with G.I. Strip (to be supplied by contractor) of size 35x6 mm for a minimum lenght 6 m. treatment of soil with highly condctive substance as per IS 30343 complete in all respect, result of earthing resistance to be recroded in M.B. before and after installation of earthing. The earth resistance after earthing should be less than 1 Ohm.
Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod to proper depth and connecting the earth electrode with the help of G.I. wire as per construction manual.
Fabrication of MS Channel angle iron etc in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESPO schedule and local approved drawing.
Excavation of earth for stay pit of size 0.6x0.6x1.2 mtr in all types of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work.
Fixing, tightening and nozzling of stay with pole and stay rod on required tension as per drawing/manual in 11 KV Line.
Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand) block including cost of Cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO Manual.
Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all types of soil including proper dressing of sides and ramming of bottom including etting out the excavated soil and disposal of surplus excavated soil as directed complete work.
Erection of SP-33 single support pole in proper level and alignment along with fixing of all accessories like top channel,& clamps as per RESPO manual.
Erection of SP-55 single support pole in proper level and alignment along with fixing of all accessories like top channel & clamps as per RESPO manual.
Erection of Sp-55 double support pole in proper level and alignment along with fixing of all accessories like top channel, X bracings & clamps as per RESPO manual.
Muffing of poles size 0.45x0.60 cm radius with 1:3:6(1 cement:3 coarse sand :graded stone 10 mm nominal size) block size 45 cm height from ground level including cost of cement,stone and sand etc.
Excavation of earth of size 2.1x2.1x1.2 meter for DTR Plinth.
Cement concreting work in ratio 1:4:8 for DTR Plinth.
Brick work in 1:4 ratio for DTR Plinth.
RR massonary work in 1:6 ratio for DTR Plinth.
RCC Work of 1:2:4 ratio 15 cm thickness for DTR Plinth.
Cement Plaster on side walls in 1:4 ratio on DTR Plinth.
Erection, providing and fixing of wire mesh of size 50x35 mm around plinth and toe wall duly welded with frame of M.S angle iron 35 x35x6 mm and strip of size 35x6 mm in mid of each side along with wire mesh (width of wire mesh 1.5 meter) with the height of 0.5 meter above the plinth and 2 meter above the toe wall with 1 No. gate and locking arrangment in the toe wall size including grouting of 6 Nos. legs in the ratio in block of size 0.25x0.25x0.45 meter including gravlling of shingle of size 20 to 40 mm and complete painting of wire mesh with aluminium paint with two coat (Including the cost of cement and all material).
Installation / mounting of new 400 KVA Tranformer on plinth structure and fixing of channel / angle etc. and making all connections of HT and LT side and its complete commissioning.
Laying, Spreading, Stringing and sagging of 11 KV/33 KV line in 3 phase (3 Phase 3 wire) of ACSR Dog as phase wire with G.I. earth wire complete including fixing of all accessories in 3 Nos. conductor in parallel with binding and jumpering as per profile and profile and sagging chart.
Laying, Sagging & binding of AB cable of size 120 sqmm.(Only for cable, additional provisions to be made for matching accessories installation, case of any network modification i.e additional pole etc. and for actual connection, disonnection as per site condition.
Cartage of ST pole SP-33 Poles from store centre to construction site with loading, unloading at both points and proper stacking. (Distance 0-20 Km)
Cartage of ST pole SP-55 Poles from store centre to construction site with loading, unloading at both points and proper stacking. (Distance 0-20 Km)
Cartage of other material (other than poles) by vehicle from Store Center to nearest construction site Store including loading and unloading at both ends (distance 0-20 Km)
Cartage of the 400 KVA transformer from store center to construction site with loading and unloading at both points.(Distance 0- 20 Km)
Headload cartage of SP-33 Pole from road to site (distance 0-1 Km).
Headload cartage of SP-55 Pole from road to site (distance 0-1 Km).
Headload cartage of small material (distance 0-1 Km).
Headload cartage of 400 KVA transformer from road to site(distance 0-1 Km)
Installation of LT Distribution Box 3 Phase for LT AB Cable.
Fixing of L.T.Bare Neutrel PG Clamp 50Sqmm to 50sqmm Line to Line.
Fixing of L.T.Bare Neutrel PG Clamp 50 Sqmm to 25 sqmm Line to Box.
Fixing of heat Shrink End Cap Suitable for AB Cable.
Fixing of mid span insulated Jointing sleeves for AB Cable.
Laying and Fixing Insulated Cable LT XLPE Alu. Cond. Power cable.
Fixing of MS Clamp for STP Poles with Nuts and Bolts.
Fixing of Dead end Clamp with I Hook.
Fixing of Suspension Clamp with I Hook.
Fixing of Insulated Piercing Connector for Line to Line taping 120 to 120 sqmm.
Fixing of Insulated Piercing Connector for Line to Box 120 to 25 sqmm.
Annexure-B (SUPPLY ITEMS)(As per UPCL Norms)
Supply of 9 Mtr Long STP 410 SP-33 (BPHD GAL).
Supply of Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6).
Supply of MS Angle 65x65x6 mm.
Supply of MS Channel 100x50 mm.
Supply of 11 KV Polymer Disc Insulator (B&S) Type.
Supply of 11 KV Polymer PIN Insulator with PIN.
Supply of Disc Fit. B&S Type Dog/Racoon 70 KN
Supply of Earthing Rod MS 20x2500 mm.
Supply of Stay set GI 16x1800 mm.
Supply of Stay Wire GI 7/3.15MM/ 7/10SWG
Supply of ACSR Dog Conductor.
Supply of LT XLPE Cable 1x400 Sq.MM.
Supply of LT XLPE Cable 3x120+1x95 Sq.MM
Supply of GI Earthing Strip 35x6
Supply of LT Bare N.Conn., PG Clamp L-L 120-120 mm2
Supply of Nut & Bolts
Supply of Universal I Hook
Supply of PG Clamp 95-25 Sq.MM
Suppy of X Arm Holding Clamp
Supply of Suspension Clamp
Supply of Stay Clamp off size.
Supply of double Pole Clamps with N/B for SP-55
Supply of Dead End Clamp for AB Cable.
Supply of Mid Span Insulator J.sleeve for LT ABC
Supply of Share head type Insulated piercing connector body molded from high quality mechanical climate and UV resistant glass reinforced polyamide, hot dipped galvanized bolts & contact teeth ABC size 120 sqmm to 25 Sqmm
Supply of SMC Three Phase L.T. Distribution Box with inbuilt panal lock, Al bus bar RYB 25x6mm., Al Busbar N. 40x6mm. for connection of L.T. consumer (Sintex make or other ISI mark reputed company ) with Panel Lock with key).
Supply of PRC 120-120
Supply of HS Type End Caps for LT AB Cable 120 Sq.MM
Supply of Aluminium Lugs O type 25 MM (4x25)
Supply of Al. LUG Crimping (400) Sq.MM
Supply of MS Half Clamp for LT Distribution Box.
MANRAJ ELECTRICAL & INFRASTRUCTURE (BID ID -403328)
PERFECT ELECTRICALS AND ENGINEERS (BID ID -403160)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.70 MB
TN302526tenderdocuments.pdf
Tender Documents • 1.68 MB
FormAandB.pdf
Other Document • 0.67 MB
GeneralInstruction302526.pdf
Other Document • 0.79 MB
TechnicalSpecification302526.pdf
Additional Documents • 7.71 MB
BOQ_104046.xls
BOQ • 0.35 MB
Dateextension302526.pdf
PDF • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .