Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹12.3 L+₹17,510 (1.45%)Rejected-Finance 161 MISSION INTER COLLEGE ROAD VILL PITHORAGARH DISTRICT PITHORAGARH STATE UTTARAKHAND PIN 262501 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262501 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹14.2 L+₹2.1 L (17.5%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹11.4 L
Closing Date
28 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
CA NO. CWE /HILLS /PGH/34 OF 2021-2022 REPAIR/ REPLACEMENT OF HT ELECTRIFICATION AND CONNECTED WORKS AT MIL STN DHARCHULA UNDER GE PITHORAGARH
2021_MES_469391_2
CA NO CWE / HILLS / PGH/34 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
DHARCHULA
CLASS E
10 documents required · 10 mandatory
₹500
GE PITHORAGARH
Yes
23 Nov 2021
27 Sept 2021
30 Oct 2021
27 Sept 2021
28 Oct 2021
5 Oct 2021
28 Sept 2021 - 4 Oct 2021
60 days
Amount
Dismantling of old stay assembly and M&L for stay assembly complete with stay rod 20mm dia including stay wire 7/3.15 mm fixed to stay of poles including necessary stay clamp of flat iron , nuts and bolts, etc and shown in electrical plate of SSR part-1 2009 complete all as specified and directed. Note:- Excavation, earth work and concrete shall be measured & paid separately under relevant items.
Dismantling of old ACSR conductor of any type and S&F ACSR conductor of any type and size stretching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between spans etc complete all as specified and directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
M&L in repair pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 1100 volts grade complete all as specified and directed.
M & L in repair disc type insulator, porcelain, vitreous white, brown or green 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
Dismantling unserviceable GOD and S&F triple pole mechanically operated with twelve insulator, 11000 volts grade HT gang operated air break switch (GOD) horizontally/ vertically operated complete with operating mechanism using GI pipe 25mm dia suitable for operating mechanism working from ground level for current rating upto 200 Amps capacity complete all as specified and directed.
Cutting/ Trimming the tree branches of any size touching/ embaracing the OH line of HT up to 1.5 Mtr on both side of the OH line & upto 1.5 RM above the over head line including removing the same from site to a distance not less than 250 Mtr away complete all as specified and directed. including providing T&P where required. Note:- Distance between two pole cosiderd as one span
Unbinding ACSR conductor of any type from insulators and re-fixing the same on insulators of HT poles after tightening/ re-stretching to achieve the permissible sag in between spans with and including 2mm dia aluminium binding wire complete all as specified and directed. Note :- Distance between two poles considered as one span.
Supply, laying & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm including taking down of old unserviceable cable complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified and directed. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I
Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed.
M&L for PCC 1:4:8, type D2 using 40 mm stone aggrigate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded aggregate as in coping etc complete all as specified and directed.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long), staying the poles in a truly vertical position including painting steel tubler pole exposed surface with two coats of aluminium paint over a coat of red oxide primer and providing 3 bends/ straps with paint red signal post colour and two bends with black synthetic enamel paint 300 mm apart from plinth block and numbering of pole and painting embedded portion of pole with one coat of bituminious paint including dismantling of old pole complete all as specified and directed.
Shifting of HT poles 11 mtr height after breaking of PCC, taking out from trench, closing the trench, shifting and re-fixing at the location where as directed. Including earth work, PCC work etc complete all as specified and directed.
M&L for disconnecting the transformer of capacity 150/160 KVA from the electrical system, taking out and shifting for repair to workshop, drain out old transformer oil, opening the top cover of the transformer and taking out core with limbs and primary windings after the disconnecting and removing iron core, removing damaged of primary windings etc. re-assembling transformer winding and core heating including insulating and packing material in order to take out all moisture from the transformer assembly complete, lowering the core assembly with winding in transformer body, connection work and re-assembling in position top cover, conservator, breather with relay control wiring complete including transportation of transformer back from workshop to site, installation of transformer on foundation, commissioning and testing with system satisfactorily complete all as specified and directed.
M&L for copper wire complete as per existing guage for existing numbers of turns of transformer winding of capacity 150/160 KVA complete all as specified and directed.
Dehydration/ Filtration of transformer oil of existing transformer by filtration machine to improve the di-electric strength of transformer oil upto and above 40 KV including transportation of filtration machine to the site complete all as specified and directed.
Supply & filling topping up transformer oil (ISI marked) duly centrifuged and tested for di-electric strength not below from 45 to 60 KV in transformer complete all as specified and directed.
M&L for gasket set made out of cork sheet cut into shape sticking on transformer body with adequate quantity of adhesive to make the complete transformer body leak proof complete all as specified and directed.
S&F cradles, hexagonal/ rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia including dismantling of old wire complete all as specified and directed.
M&L in repair earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel earth plate surrounded by alternative quantity of charcoal dust & salt to a packed thickness of 15 cm on all side upto 15 cm above & below the plate, excavation earth work, returning, filling in removal of surplus soil upto 50 mtr on side, as shown in electrical plate No. 5 connected to earthing test point including PCC pit in PCC 1:2:4 type B1 using 20 mm graded stone aggregate pit cover in RCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate with 6 mm dia mild steel round bars @ 100 mm C /C with 12 mm dia lifting handle incl providing 20 mm dia GI pipe medium grade for watering, funnel & wire mesh etc complete including testing on completion complete all as specified and directed.
Cutting of bushes/ grass, unwanted veg growth in and around the electrical installations, transformers, panel boards, HT 4 pole / 2 pole structures, HT electric poles, etc in complete station and disposed off to the location not less than 50 Mtr all as required at site complete all as specified and directed.
M&L replacement of silicagel pot filled with fresh silica gel and oil in bowl/ cap of the transformer capacity from 63 KVA to 315 KVA and fleshing of threading where it is fitted all as required at site complete all as specified and directed.
M&L for painting to 4/6 poles structure of 11 mtr long steel tubular pole including cross arms, channel bracing, earth pipe , anti climbing device, clamps, GOD insulators mounting channels, with one coat of aluminium paint including preparation of old painted surfaces properly and providing 3 bands/ straps 25 cm wide with paint red signal post office colour and 2 band 25 cm wide with white synthetic enamel paint 300 mm apart from plinth block and numbering of poles 100 mm height with white paint in black box of size 125x125mm complete all as specified and directed. Note:-(i) HT tubular pole shall be 11 m long. (ii) All T&P should be provided by contractor
M & L for painting to 2 poles structure of 11 mtr long steel tubular pole including cross arms, channel bracing, earth pipe , anti climbing device, clamps, GOD insulators mounting channels, with one coat of aluminium paint including preparation of old painted surfaces properly and providing 3 bands/ straps 25 cm wide with paint red signal post office colour and 2 band 25 cm wide with white synthetic enamel paint 300 mm apart from plinth block and numbering of poles 100 mm height with white paint in black box of size 125x125mm complete all as specified and directed. Note:-(i) HT tubular pole shall be 11 m long. (ii) All T&P should be provided by contractor
Maintenance and complete overhauling of 11 KV VCB of existing make/ type/ mode/ capacity including disassembling of operating mechanism parts well cleaning with petrol and CRC-226 and replacing unserviceable spare parts reassembling of parts including well cleaning the complete panel board, main bus bar, decarbonizing all joints bus bar CTS, PTS, spouts metal parts and making VCB perfect operating in manual and electric mode and calibration & checking of tripping system of 11 KV circuit breaker through IDMT over current and earth fault relay at plug setting infented in service by primary current injection method to ensure proper function of trip coil control circuit etc. during fault condition setting by expert from authorised agency of state electricity board including submission of calibration certificate complete all as specified and directed. Note:- Spare parts required to make VCB functional will be measured and paid separately under respective items.
Supply only Breaker control switch 10A 660V
Supply only Closing coil
Supply only Breaker on off switch plastic handle
Supply only Vaccum interrupter bottle module with ceramic housing as same as existing or approved by GE/ suitable for outgoing VCB of 400 Amp rating
Supply only Red,Yellow, Blue phase indicator neon light
SHAHJEE FRIDGE SERVICE
kumaon and hills strument engnering services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .