Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹45.1 L
EMD Value
₹90,140
Closing Date
16 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North) Binnaguri
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
SPL REPAIR OF OTM BDLG NO P-10 AND SEWAGE LINE APPROX 235M AND 22 NOS OF CHAMBER UNDER GE NORTH BINNAGURI
2025_MES_721028_4
8701 / 17 / 2025-26 / 09 / E8
Open Tender
Civil Works
Item Rate
180 days
Binnaguri cantonment
D class catg a(i)
8 documents required · 8 mandatory
₹500
GE (North) Binnaguri
₹90,140
Yes
15 Nov 2025
15 Nov 2025
18 Dec 2025
15 Nov 2025
16 Dec 2025
24 Nov 2025
Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles to store and rubbish off the premises including taking down cement plaster complete all as specified and as directed.
M&L for RCC 1:1.5:3 Type A1 ( using 20 mm graded stone agg) as in slab supported on walls chajjas complete all as specified and as directed.
M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 60/50 x 125/105 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
M&L for brick works with fly ash bricks straight or curved on plain exc 6m mean radius built in cement mortar 1:6 complete as directed.
S&F of Factory made partly glazed ie. upper panel will be wire mesh fitted externally in the clear space & lower panel will be plain colour PVC sheet 5mm thick PVC door shutter 30mm thick (style ) consisting of frame made out of M.S tubes for top & bottom , rails , MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for sides and plain colour PVC sheets for botop rail , lock rail & bottom rail on either side & as gap insert for top rail & bottom rail , paneling of plain colour PVC sheet PVC sheet beading , and jointed together with solvent cement , complete all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary fittings shall be paid separately)
Supply only liquid water proofing compound complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified
M&L for 10mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying waterproof coating finished even and smooth without using extra cement complete all as specified and as directed.
S&F for Reinforced concrete pipe (SWR) bends any radius fixed to pipes/steel gutters etc bore of bend 200mm complete all as specified and as directed
S&F for Reinforced concrete pipe (SWR) bends any radius fixed to pipes/steel gutters etc bore of bend 150mm complete all as specified and as directed
S&F for RCC (SWR) branch piece, single (Single Y) equal or unequal radius fixed to pipes/ steel gutters bore of branch pipe 200mm complete all as specified and as directed
S&F for RCC (SWR) branch piece, single (Single Y) equal or unequal radius fixed to pipes/ steel gutters etc complete all as specified and as directed
M&L, cement concrete 1:4:8 type D-2 bed to 200mm dia bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and as directed
M&L, cement concrete 1:4:8 type D-2 bed to 150mm dia bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and as directed
Demolition & breaking up drain pipes(salt glazed ware, AC or reinforced concrete) set in cement mortar, internal dia of pipe 200mm complete all as specified and as directed.
M&L Cement concrete 1:4:8 type D2 (using 40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for returning, filling in including spreading, leveling watering & well ramming in layers n. exc 25cm complete all as specified and as directed.
M&L for removing excavated material soil beyond 50m and upto a total distance of 250m depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 as in surface channel, bencing and drains in manholes complete all as specified and as directed.
Demolition of reinforced cement concrete of any description of in any position such as precast manhole cover or cover slabs of septic tank etc (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
M&L for precast RCC 1:2:4 type B1 (using 20mm graded aggregate) as in landing cover slabs (for man holes etc) chullah hoods, chajjas, water troughs, managers shelves and similar articles with plain face complete all as specified and as directed.
Excavation in trenches n. exc 1.5M wide and n. exc 1.5m in depth for foundation etc in soft/loose soil. complete all as specified and as directed.
M&L hard core of broken stone or boulder for gauge n. exc 63mm, deposited spread and leveled in layer n.exc 15cm thick watered and rammered to a true space complete all as specified and as directed.
M&L for 50mm thick cement concrete 1:3:6 type C1 (using 20mm graded aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for cutting into existing manholes for connecting new drains for internal dia of 150mm pipe and making good to pipe and rendering, cutting out existing bendhing for and forming branch ch
annel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-I smooth finished, and reforming benching as required complete all as specified and as directed.
M&L for cutting into existing manholes for connecting new drains for internal dia of 200mm pipe and making good to pipe and rendering, cutting out existing bending for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-I smooth finished, and reforming benching as required complete all as specified and as directed.
M&L for rolled mild steel framed work in tubular trusses such as roof trusses,trussed,purlines, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etcs including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St 240 complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
All as per item No 117 above but One socket out let 5/6 amps point on the independent board
All as per item No 117 above but One socket out let 5/6 amps point on the same board
Taking down copper/aluminum point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
S&F of Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
All as per item No 117 above but One bell point controlled by one way switch 5/6 amps.
S & F Bell Ding Dong, AC Single Pole, 220/240Volts, surface type complete all as specified and directed.
S&F of Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed.
S&F of Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed.
S&F of Modular bell push, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of stepped type modular electronic fan regulator 120 watt 2 module suitable for 1200/1400 mm sweep energy saving fans,ISI marked complete all as specified and directed.
S & F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S&F LED
white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and directed.
S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2 KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) with proper colour coding as earth continuity conductor connected to common earth dolly , modular sheet steel sunken terminal box of appropriate size suitable for modular switch/ fittings concealed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. all as specified and as directed for the following :- (a) One light point controlled by one way switch 5/6 amps.
S&F IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified.
All as per item No 117 above but One ceiling fan/Exhaust fan point controlled by one way switch 5/6 amps.
Taking down carefully Ceiling fan from its original position and refixing / hanging after plaster work including painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc, all as specified and as directed complete all as specified and directed.
All as per item No 117 above but wiring with 2.5 sq mm single core multistranded copper conductor including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) with proper colour coding as earth continuity conductor connected to common earth dolly , for one socket out let 15/16 amps point on the independent board complete all as specified and directed
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, 415Volt IP-20 protection suitable for fixing MCB"S/lsolators with and including taking down old one complete all as specified and directed.
S&F MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed. Make :L & T ,Cat No: BB40630C,& Eqv to Legrand/ Hager/ABB/C&S.
S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one as specified and as directed.
S & F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete incl removal of old unsv fitting all as directed by Engineer-in-Charge.
Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE : Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
Per Point
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (1”) dia,complete with all accessories all as specified and directed by Engineer-in-charge.
S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed.
M & L for sheet metal enclosure fabricated out of 2.0 mm thick CRCA sheet, totally enclosed type, dust & vermin proof, with suitable sized supporting MS angles & suitable openings at top & bottom for entry of outgoing / incoming cables, fixed with nuts & bolts & front side openable with hinged shutter with suitable locking arrangement duly painted with 2 coats of powder coated paint over a coat of red oxide primer (spray paint) with minimum dimensions (90 x 75 x 20 cm ) flush to wall for incorporating 01 No TPN DB, 04 Nos electronic meters etc complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate of SSR Part- I including testing on completion all as directed and as specified.
Each Job
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 2 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A').complete all as specified and as directed.
All as per item No 117 above but One light point controlled by two way switch 5/6 amps.
S&F of Modular switch, single pole, two way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tender.pdf
Tender Documents • 1.93 MB
BOQ_828693.xls
BOQ • 0.48 MB
Sch.pdf
Additional Documents • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .