Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹6.6 LAdmitted-Finance | -34.00% | ₹6.6 L | L1 | Admitted-Finance |
| 2 | L2₹6.7 LAdmitted-Finance | -33.00% | ₹6.7 L | L2 | Admitted-Finance |
| 3 | L3₹8.5 LAdmitted-Finance | -15.00% | ₹8.5 L | L3 | Admitted-Finance |
| 4 | L3₹8.5 LAdmitted-Finance | -15.00% | ₹8.5 L | L3 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | - | Rejected-Technical GST link not uploaded |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
12 Mar 2026, 4:00 pmClosed
Executive Engineer REW Rajouri
Office of the Executive Engineer REW Rajouri
Please refer BOQ
2026_RDPR_305129_3
e-NIT No. 334 REW Rajouri of 2025 Dated 03-03-2026(Retender)
Open Tender
Civil Works
Rajouri
Please refer tender documents
2 documents required · 2 mandatory
₹500
Executive Engineer REW, Rajouri
₹20,000
Yes
16 Mar 2026
7 Mar 2026
13 Mar 2026
7 Mar 2026
12 Mar 2026
7 Mar 2026
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.(AKOS 70% & H/Rock 30%(To be Paid as per Actual)
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: in: AKOS 80% and H/R 20%
P/Laying of cement conct. 1:5:10 Of specified grade excluding the cost of form work, cement using 40mm N/ size of agg.
P/Laying of cement conct. 1:3:6 Of specified grade excluding the cost of form work, cement using 20mm N/ size of agg
Supply and Dumping of Stone boulder
P/Laying reinforced cement conc. 1:1.5 :3 Of specified grade in RCC work excluding the cost of form work, cement using 20mm N/ size of agg.All work upto Plinth Level.
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforcement for RCC work including straightening , cutting, bending, placing in position and binding all complete
Brick work with brick of class designation 75 above plinth level upto floor V level in cement mortar 1:6
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Providing and filling of sand & stone under flooring, ramming, watering all complete
Providing and filling of sand & stone under flooring, ramming, watering all complete
Centering and shuttering including strutting propping etc and removal of form for foundation footings, bases of columns etc for mass concret.
d) Columns, pillars, piers, abutments, posts and struts
b) Suspended floors, roofs, landings, balconies and access platforms
c) Lintel, beams, plinth beams, girders, bressumers and cantilevers
e)Edges of slab(under 20 cms wide)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel of 1.25mm/1.60mm thickness including hinges jamb, lock, jamb, bead , including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge Profile B Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class Kail wood
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class Kail wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. : Second class Kail wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Ply wood 5 ply, 9 mm thick, Decorative ply wood both side decorative veneer (type 1) conforming to IS 1328 BWR type
Painting with symthetic enamel paint of approved brand over a priming coat red oxide on new steel work two or more coats
Providing/laying 12 mm cement plaster of mix 1:6 fine sand
Providing 15 mm cement plaster of mix 1:6 fine sand
6 mm cement plaster to celling of mix 1:3 fine sand
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20mm nominal size stone aggregate.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm (Matt Finish)
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed pvc conduit, with pianotype switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for computer/ machine point in 3x2.5 sqmFRSL PVC copper insulated conductor single core cable on surface/ recessed in PVC conduit/ channel with 1 no 5/6 Amp switch 2 no socket; phenolic laminated sheet, suitable size MS box complete job( incl. cost of conduit and insulated wire
Wiring for heating point in 3x4sqm FRSL PVC copper insulated conductor single core cable on surface/ recessed in PVC conduit/ channel with 1 no 15 Amp switch 1 no socket; phenolic laminated sheet, suitable size MS box complete job( incl. cost of conduit and insulated wire) Circuit wire
Supplying & fixing 1400 mm sweep ceiling fan of standard quality with 1'-6" long fan rod and necessary connections complete job
Supplying and fixing of 20/22watt LED 4feet tube light fitting/fixture aluminnium hosing with 2000 lumens and min lumen sefficiency 100 Lumens/watt
Sand 25 km by M/T
Agg. 25km by MT
Bricks 15 km by M/T
PROVIDING AND FIXING SIGN BOARD INCL(5x4)plaster b/s with Granite stone plate incl. WRITING, PAINTING .
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
BOQ_991057.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid