Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC 2076 2077 CHIRIMAR MOHALLA AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹18.3 L+₹11,911 (0.66%)Rejected-AOC HOUSE NO 3363 SECTOR 27 D CHANDIGARH | NA | NA | 160001 | L2 | Rejected-AOC OTHER THAN LOWEST | |
| 3 | L3₹19.8 L+₹1.6 L (9.00%)Rejected-AOC 411 STREET NO 4 PANCHVATI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L3 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE Chandigarh
GE Chandigarh N Area Pin-160003
REPAIR/ MAINTENANCE OF SEWAGE DISPOSAL SYSTEM, MANHOLES, BOUNDARY WALL, KOTA STONE / PARKING TILES , PLASTERING, BRICK WORK ETC AT DAD RESIDENTIAL COLONY SECTOR 35-B AND PCDA BUILDING SECTOR 09 UNDER GE CHANDIGARH
2024_MES_669523_1
GE/CHD-35/2024-25
Open Tender
Civil Works
Item Rate
334 days
Chandigarh
Class E category a(ii) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹40,000
Yes
21 Nov 2024
31 Aug 2024
30 Sept 2024
31 Aug 2024
28 Sept 2024
16 Sept 2024
1 Sept 2024 - 7 Sept 2024
Amount
Deploying safaiwala for attending/ clearing daily complaints of blockages of floor traps, gully traps, WC's (Indian/ European) at Ground floor or above ground floors (upto fifth floor) upto first manhole including cleaning through door bends with and including necessary T & P required for this purpose. Note :- (a) The contractor shall provide 04 safaiwalas, per day for 8 Hrs to attend the above complaints for complete tenure of contract. The quoted rate by the contractor against this item shall deemed to be included the cost of the aforesaid manpower. (b) All the safaiwalas shall attend the MES complaint cell at Sector 35 B at 09:00 Hrs to collect the complaints and submit the same duly signed by the occupant at 1630 Hrs in the complaint cell. It will be responsiblity of contractor to ensure their attendance & completion of complaints . (c) Attendance register will be submitted with RAR duly signed by concened JE, Engg-In-Charge and contractor. (d) A panalty of @ Rs 1000/- per person per day will be deducted if any safaiwala is found absent. (e) The contractor will ensure the cleaning/clearing of all the complaints (irrespective of Nos) within 24 Hrs by deploying additional safaiwalas if needed. Nothing extra will be paid on this account. (f)Contractor shall be solely responsible for supplying all the safety measures required by the safaiwalas during working hours. (g) All the waste material/ sludge shall be disposed off out of MoD land.
Dewatering/Desluding of manholes (any size and depth), desilting and removing sludge from manholes as in foul conditons and removing of sludge beyond MoD land and deposited in borrow pits including excavation of borrow pits and covered with 10cm thick layers of soil complete all as specified and directed. Note for item No. 2: Dewatering /desludging shall be done by suction pump / any mechanical means and disposal by truck mounted trailors to dispose off sludge etc beyond MOD land earmaked by local Muncipal Corporation) & UT Chandigarh
Cleaning of underground sewage line/storm water drain pipes up to and including 200 mm bore of any type including in between manholes to manhole for cleaning and well flushing with water after cleaning .(The rate include for taking off manhole cover and re-fixing the same after cleaning /removing the waste materials and sludge to a distance near by suitable distance and depositing in the borrow pits as directed by Engineer-in-Charge.(The rates also include for earth work /excavation and removal of surplus spoil for borrow pits) by mechanically complete all as directed by Engr-in-Charge.
Cleaning of under ground sewage line by excavation and breaking the existing sewage line (minimum two pipe length), removing the blockage, rejoining with new pipe length complete incl necessary material and labour, returning, filling, supply of new NP2 pipe of required lengths and required bore, beding the new pipe length with PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) all as directed in situations where cleaning is not possible by rodding, at any depth complete all as directed for 150mm bore pipe complete all as directed by Engr-in-Charge.
Cleaning of under ground sewage line by excavation and breaking the existing sewage line (minimum two pipe length), removing the blockage, rejoining with new pipe length complete incl necessary material and labour, returning, filling, supply of new SWG pipe of required lengths and required bore, beding the new pipe length with PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) all as directed in situations where cleaning is not possible by rodding, at any depth complete all as directed for 150mm bore pipe complete all as directed by Engr-in-Charge.
All as per ser item No 04 here-in-before but 200 mm bore. Note for serl 4 & 5 :- (a) Excavation & earth filling including disposal of surplus soil to near by low lying area shall be deemed to be included in the rate quoted against this item. (b) The complaints where cleaning of blockage is not possible with rodding and is to be cleared by breaking existing line.
Excavating in trenches in soft/loose soil, n.exc. 1.5m wide and n.exc 1.5 in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n.exc. 10 sqm on plan and n.exc 1.5m in depth and getting out.
All as per item No 7 above but exc. 1.5 m but n.exc. 3.00 m in depth
Demolition and breaking up drain pipes, 150 mm internal dia (Salt glazed stoneware, AC or reinforced concrete) set in cement mortar including haunching and bed concrete.
Demolition and breaking up drain pipes, 200 mm internal dia (Salt glazed stoneware, AC or reinforced concrete) set in cement mortar including haunching and bed concrete.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 150 mm bore, including packing under & haunching against the sides of pipes after they are laid and tested.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 200 mm bore, including packing under & haunching against the sides of pipes after they are laid and tested.
M&L for providing reinforced concrete pipes , class NP2 laid and jointed complete with collars 150mm dia (internal) laid in trenches & jointed etc all as specified and by Engr-in-Charged.
M&L for providing reinforced concrete pipes , class NP2 laid and jointed complete with collars 200 mm dia (internal) laid in trenches & jointed etc all as specified and by Engr-in-Charged.
Demolition of brick work built in cement mortar incl all corners/arches pillar etc cleaning and stacking of serviceable bricks for reuse and removal of unserviceable material complete all as specified and directed.
M&L for brick work with sub class 'B' old size brick, straight or curved on plain exceeding 6mtr mean readius built in CM 1:6 complete all as specified and directed.
All as per item No 16 above but except bricks
M&L for 15mm thick cement plaster in CM 1:4 over concrete/brick surfaces and finishing the surface even and smooth (without using extra cement) etc. complete all as specified and directed.
M&L for 15mm thick cement plaster in CM 1:4 over concrete/brick surfaces and finishing the surface even and smooth ( using extra cement) etc. complete all as specified and directed.
Material and Labour for preparation of new plastered /concrete /unplastered surfaces and applying two coats of weather guard exterior acrylic emulsion paint (Ist quality) any tint, at over and including a coat of primer on walls complete all as specified and directed.
M&L for cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in cills, steps, bands, copings, bed plates, blocks for inserting hold fasts etc. and the like including weathering, slightly rounded or chamfered angles and throating as directed.
M&L for cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in surface channels, drains (forming fair finished) complete all as specified and directed.
Returning, filling in (soils) including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil (Soils) not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
S&F Factory made Precast RCC manhole covers with and incl frame designation LD 2.5, clear opening of frame 750x750mm ISI marked(IS 12592:2002) complete all as specified.
S&F in repairs salt glazed stoneware gully traps, 180x150mm square or round mouthed, type P complete all as specified.
S&F in repair PVC floor trap incl stainless steel gratings, 100 mm dia of outlet, including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
M&L 25 mm thick Plain cement concrete 1:2:4 Type B0 (12.5 mm graded aggregate) as in flooring, surfaces finished even and fair complete all as specified and directed.
M&L 75 mm thick PCC 1:4:8 type D2( using 40 mm graded stone aggre) as in sub base complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors,aprons etc laid ,bedded and pointed in any mortar.
M&L out door/parking tiles heavy duty for light traffic Non skid, anti scratch, heavy grip , vitreous/semi vitreous coloured , unique designs tiles 8 to 10 mm thick area of each tile of size 300 mm x 300 mm, in floors parking/outdoortiles etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for Mirror polished machine cut kota stone slab 560 mm x 560 mm x 16 to 20 mm thick in flooring over and including 20mm thick cement screed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
M&L for polished machine cut kota stone slab 560 mm x 100 mm 16 to 18 mm thick in riser of steps, skirting/ shelves etc. round edges over and including 15 mm thick screed bed or bedding layer in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
M&L Hardcore of gauge n exc 63 mm of broken stone or boulders, deposited, spread, levelled in layers n exc 15 cm thick, watered and rammed to a true surface, complete all as specified.
M&L Machine Pressed Precast concrete Interlocking paver Block with grey cement and pigment any Shape and Size confirming to IS-15658-2006 of 60mm thick M-35 grade on 20 mm thick sand cushion and filling of joints with dry cement and sand mortar1:4 complete all as specified and directed.
M&L machine pressed factory made chequered tiles of required size, shape & colour 22 to 25 mm thick laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry with grey cement and pigment complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutter from frame) not exc 1.5 Sqm each with mongry including Cutting holes into through brick wall and making good to dismantled portion in CM (1:3) or PCC (1:2:4) complete all as specified and as directed
Taking down chowkhats with shutters (without taking off shutter from frame)exc 1.5 Sqm but exc 4 sqm each with mongry including Cutting holes into through brick wall and making good to dismantled portion in CM (1:3) or PCC (1:2:4) complete all as specified and as directed
S&F 5 mm thick sheet glass pane tinted/plain/Figured glass type, with 5 micron thick black film ordinary quality and ruber, cleting, silicone,glazing with oil putty etc in each pane complete all as specified and directed.
S&F aluminium powder coated (min thickness of powder coating 50 micron) frame for door , windows, ventilators and weight of aluminium section not less than 0.55 kg/Rm with one or more rebates including joining cleat/aluminium beading for fixing etc complete all as specified.
S&F aluminium powder coated (min thickness of powder coating 50 micron) work for aluminium door shutters, weight of aluminium section not les than 0.55 kg/Rm aluminium section including necessary joining cleats/aluminium beading, glazing clips clips, ruber neoprene gasket packing, handles 2 Nos, tower bolt 2 No in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
S&F aluminium powder coated (min thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars,including (double shutter) glazing bars and without glazing bars weight of aluminium section not les than 0.55 kg/Rm including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.), tower bolt 2 Nos complete all as specified
S&F Stainless steel work such as Frames , grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred doors;ladders; framed balusters; walk ways; railingswork on forming to grade 304 complete all as specified and directed.
Taking down cement plaster from wall's including raking out joints hacking for key scrubbing down with water and dispose off debries out side MoD land complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick square/ rectangular) area of each tile of size 300 mm x 300 mm mm thick, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for Glazed ceramic coloured /printed tiles of size 450mmx 300mmx7mm thick as in skirting/dado setting & jointed with neat cement slurry over & including 10mm thick rendering of cement sand mortar (1:4) and pointed with coloured cement to match with surface of tiles complete all as specified and as directed.
Dismantling of cast iron pipe / reinforced concrete/PVC drain pipes/PVC (SWR) pipe etc, 100/75/50mm, jointed in cement mortar and taking out of trenches and wall, if required complete all as specified and directed.
S&F for 110mm dia PVC (SWR) pipes single socketed pressure rating not less than 4 Kg/SQ Cm, ISI Marked with rubber ring joints, laid in trenches /fixed to wall/floor complete all as specified and directed.
S&F 75 mm PVC (SWR) pipes single socketed,pressure rating not less than 4 Kg/SQ Cm, ISI Marked in any length with rubber ring joints, laid in trenches /fixed to wall/floor complete all as specified and directed.
S&F 110 mm PVC (SWR) ISI Mark bends any radius complete all as specified and directed
S&F 75 mm PVC (SWR) ISI Mark bends any radius complete all as specified and directed
Supplying and fixing in existing position the new vitreous chinaware wash down water closet (padestal pattern) light colour/white With plastic seat cover including P’ or ‘S’ trap, plastic seat cover white and connection to out going pipe & to flushing pipe, anti-syphonage pipe etc as directed by Engr-in-Charge including taking out of old EWC complete all as specified and directed
S & F in repairs Vitreous China Squatting pan 'orissa pattern size 580x440 white with integral foot rests with `P' or `S' trap, front or back inlet(excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including cement concrete complete including making good to floor.
S&F in repair 10 litre capacity PVC Valveless syphonic action type flushing cistern low level white with inlet ball valve float and handle incl bracket as fixed in repair complete all as specified and as directed.
His Construction Company (BID ID -3102999)
M/s Super Trading Corporation (BID ID -3119258)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .