Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹24.2 L+₹2.2 L (10.2%)Rejected-Finance GORUBANDHA MISSAMARI 784 506 | SONITPUR | ASSAM | 784506 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹24.3 L+₹2.4 L (10.8%)Rejected-Finance HARIGAON PO NIKAMUL SATRA DIST SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹27.7 L+₹5.7 L (26.2%)Rejected-Finance LAKHPURA BUTCHERY MISSAMARI DIST SONITPUR ASSAM PIN 784506 | MISSAMARI | SONITPUR | ASSAM | 784506 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹29.1 L+₹7.2 L (32.7%)Rejected-Finance VILL LAKHOPARA PO GARUBANDHA DISTT SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MISSAMARI
PO-Missamari Dist-Sonitpur Assam
REPAIR/MAINTENANCE OF GEYSERS UNDER GE MISSAMARI
2023_MES_622319_1
8431
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE MISSAMARI
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
GE MISSAMARI
₹60,000
Yes
18 Dec 2023
9 Oct 2023
1 Nov 2023
9 Oct 2023
30 Oct 2023
23 Oct 2023
Amount
Taking down geysers of any type and any capacity due to rusting of bolts/seepage of wall and re-installation at any location including S&F in repair of heavy duty pin type fastener 4 inch Job long and making necessary inlet/outlet electric & water supply connections from existing source to geyser complete all as specified and as directed
M&L Point Wiring with 2.5 Sqmm Copper Conductor single core PVC insulated Flame Retardant Low Smoke (FRLSH) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including PVC Casing and Caping medium grade of suitable size and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted on Sunk Mild Steel Pressed Terminal Box 1.22mm thick of suitable size duly painted with red oxide metal primer with 3.0mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 2.5 Sqmm (FRLSH) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Geyser controlled by One 1-Way Switch 15 Amp, duly fixed with copper lugs and flexible pipe from ceiling rose to fitting/fixtures complete all as specified and as directed.
M&L Point Wiring with 4.0 Sqmm Copper Conductor single core PVC insulated Flame Retardant Low Smoke (FRLSH) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including PVC Casing and Caping medium grade of suitable size and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted on Sunk Mild Steel Pressed Terminal Box 1.22mm thick of suitable size duly painted with red oxide metal primer with 3.0mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm (FRLSH) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for Geyser Point controlled by One 1-Way Switch 15 Amp, duly fixed with copper lugs and flexible pipe from ceiling rose to fitting/fixtures complete all as specified and as directed.
Inspection,checking adjustments and repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :- (a) Inspection, taking out of drain plug & dewatering and refixing the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat upto 55º C. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) The cost of spare parts required for repair & mainenance of geysers covered under this item shall be measured and paid separately under the relevant item as supply only. (j) Make of geysers covered under the scope of work :- Sidhson, bajaj, recold, crompton, orison, ditz premier, peeco, empire, shakti, sahas, konark
Supply only heating element, Round type / tikona type / banana type, 1.5 KW 230 volts, ISI marked suitable for 25/35/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA / Bajaj / Recold/Havells
Supply only heating element, Round type / tikona type / banana type, 2 KW 230 volts, ISI marked suitable for 25/35/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA / Bajaj / Recold/ Havells
Supply only thermostat switch for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. Make : USHA / Bajaj /Theta / Elcon.
Supply and fixing glass wool for geysers complete all as specified and as directed.
Supply only base assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
Supply only indicator lamp for geyser of any type colour green & red complete all as specified and as directed. Make : Usha / Bajaj/ Crompton
Supply only copper inner tank of minimum 22 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25/35 ltrs capacity geysers (wt not less than 3.75 kg) as per sample complete all as specified and as directed.
Supply only of Copper inner tank of minimum 22 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample complete all as specified and as directed.
Supply only outer body of MS sheet not less than 22 gauge suitable for 25/35 ltr geyser with white synthetic enameled paints complete all as specified and as directed.
Supply only outer body of MS sheet not less than 22 gauge suitable for 50 ltr geyser with white synthetic enameled paint complete all as specified and as directed.
Supply only plug top 3 pin 15 Amp ISI marked complete all as specified and as directed. Make : Anchor / Havells / C&S .
Supply only bottom cover of PVC suitable for 25/35 ltrs capacity geysers complete all as specified and as directed.
Supply only bottom cover of PVC suitable for 50 ltrs capacity geysers complete all as specified and as directed.
Supply and fix in replacement Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, chromium plated fancy type, screwed both ends for 15mm bore iron pipe or for union, ISI marked, fixed as in repair complete all as specified and as directed.
Supply and fix in replacement Bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, fixed as in repair complete all as specified and as directed.
Supply and fix in replacement Brass Mixer tap cast copper alloy chromium plated, fancy type, wall mounted, suitable for mixing hot and cold water screwed for 15mm bore iron pipe, ISI marked, fixed as in repair complete all as specified and as directed.
Supply and fix in replacement Stainless steel connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe, fixed as in repair complete all as specified and as directed.
Supply and fix in replacement stainless steel connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe fixed as in repair complete all as specified and as directed.
Supply and fix in replacement 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded fixed as in repair complete all as specified and as directed.
Supply and fix in replacement Switch piano flush type, single pole, one way, 16/20 Amp fixed as in repair complete all as specified and as directed.
Supply and fix in replacement shuttered socket out let, 3 Pin, 16 Amp, 230 volts piano flush type fixed as in repair complete all as specified and as directed.
Supply and laying in floor, fixed to walls and ceiling, 25mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and as directed.
Supply and laying in floor, fixed to walls and ceiling, 20 mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and as directed.
Supply and laying in floor, fixed to walls and ceiling, 15 mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and as directed.
Material & Labour for Cutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc complete all as specified and directed.
Material and Labour for Painting of outer surface of 25/35/50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and seperating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
Supply and fix in replacement Instant hot water instrument for any Itr capacity fixed as in repair complete all as specified and as directed.
Dismantling carefully solar storage water heating system of any capacity, any type for following works with testing and refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after repair as under :- (a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Supply and fixing of Spare parts. wiring etc shall be measured & paid separately.
Supply only Heating element, 3.00 KW 230 volts, ISI marked suitable for solar geyers tank of any make fixed as in repair complete all as specified and as directed.
Supply only thermostat switch for solar water heater (ISI marked) any make and size fixed as in repair complete all as specified and as directed.
Repair and welded to copper water storage tank of solar storage water heating systme of any capacity 100 to 500 LPD, to prevent any type of leakage at site with testig and refixing the same in original position makig all water / electric connection to entire satisfication of Engineer-in Charge after repair as under (a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Supply and fixing of Spare parts. wiring etc shall be measured & paid separately.
Material and Labour for Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire, drawn through existing PVC surface/ concealed conduit and connected to main board and making good disturbed surface including taking down existing unserviceable wiring complete all as specified and as directed. Note: (i) Two run each of one RM of 4.00 sqmm cable and 1 run of one RM of 4.00 sqmm cable together shall be considered as 1 running meter for payment purpose.
Supply and fix in replacement Glass collector suitable for solar water heating system of any size fixed as in repair complete all as specified and as directed.
Material and Labour in replacement for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of Capacity 20 Amps complete all as specified and directed. Make:- L&T / Legrand / Schneider / seimens
Supply and Fix in replacement MCB ,SP , 240 volt, 20Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
Supply and fix in replacement MCB ,SPN, 240 volt, 16Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
S &F in replacement Industrial Metal socket plug top 3 pin 15 Amp suitable for Existing DB ISI marked complete all as specified and directed.
Supply only PVC wide 20mm Insulation Tape of length 25 meter complete all as specified and directed. Make Anchor Grip / MS-seal / Havells
Supply and Fix in replacement for PVC casing and capping of 10 foot length in repairs duly fixed with casing pins and connecting accessories like Tee , Bends , elbow etc required as per site complete all as specified and direced. Make Presto Plast / Plaza / AKG / Harsh
Supply and Fix in replacement for PVC Conduit of 10 foot length in repairs duly fixed with Clamps on wall surfaces and connecting accessories like Tee , Bends , elbow etc required as per site complete all as specified and direced. Make Presto plast / Harsh /Plaza / AKG
S & F PVC Square Box of Size 4'' x 4'' including replacement of old UNSV one and refixing of old switch sockets as per existing at site complete all as specified and directed. Make Presto plast / Harsh /Plaza / AKG
S & F PVC Square Box of Size 7'' x 4'' including replacement of old UNSV one and refixing of old switch sockets as per existing at sitecomplete all as specified and directed. Make Presto plast / Harsh /Plaza / AKG
S & F PVC Square Box of Size 8'' x 6'' including replacement of old UNSV one and refixing of old switch sockets as per existing at site complete all as specified and directed. Make Presto plast / Harsh /Plaza / AKG
S & F ceiling fan capacitor 2.5 mfd as per site requirement heavy duty with metal body including removal old existing unsv one complete all as specified and directed. Make Havells/Universal/Sarda/Epcos
S & F ceiling fan capacitor 3.15 mfd as per site requirement heavy duty with metal body including removal old existing unsv one complete all as specified and directed. Make Havells/Universal/Sarda/Epcos
S & F ceiling fan capacitor 4.0 mfd as per site requirement heavy duty with metal body including removal old existing unsv one complete all as specified and directed. Make Havells/Universal/Sarda/Epcos
Disconnecting and taking down Ceiling Fan/Wall Mounted/Exhaust Fan/Air Circulator of any Sweep by Electrical Connections, cleaning Internally and Externally thoroughly, replacement of Split Pins, Cotter Pins and Check-nuts, etc. overhauling, lubricating with approved Lubricants, re-assembling including , re-fixing in Original Position checking smooth functioning and including electrically connected with Flexible Wire multi -stranded Copper Conductor Cable of size 23/0.0076 from Ceiling Rose to Fan cleaning all dust, etc. after repair duly painted two coats as per existing colour over a coat of primer and testing complete all as specified and as directed.
M&L rewinding Ceiling Fan 1200/1400mm Sweep of any Make and type with Super Ena-meled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for statisfactory running and testing, complete all as specified and as directed.
Supply and fixing Ball Bearing No. 6201(as approved) suitable for ceiling fans complete all as specified and directed.
Supply and fixing Gun Metal Bush (as approved) suitable for ceiling fans 1200/1400 mm sweep complete all as specified and directed.
M&L rewinding Exhaust Fan 300 / 380 mm Sweep of any Make and type with Super Ena-meled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for statisfactory running and testing, complete all as specified and as directed.
Supply and fixing Ball Bearing (as approved) suitable for Exhaust fans complete all as specified and directed.
Supply and fixing Gun Metal Bush (as approved) suitable for Exhaust fans 1200/1400 mm sweep complete all as specified and directed.
Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Sunrise Enterprise
Markson
Satya Enterprises
BEE KAAY TRADERS
M/S Mahabir Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .