| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC NO 2 GF AKSHAYRAJ APARTMENT JUBILEE CIRCLE BHUJ 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | L1 | Accepted-AOC lowest bid and reasonable | |
| 2 | L2₹56.1 L+₹8.6 L (18.2%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹57.8 L+₹10.4 L (21.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹57.9 L+₹10.4 L (21.9%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹58.6 L+₹11.1 L (23.4%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
17 Jul 2024, 6:00 pmClosed
CWE (AF) Jamnagar
CWE (AF) Jamnagar AT AF Station 1 361003
REPAIR / MAINT OF LT DISTRIBUTION SYSTEM, LT CIRCUIT BREAKER, ACB AND ALLIED WORK AT VARIOUS LOCATION UNDER GE (AF) JAMNAGAR NO 01
2024_MES_660645_1
81197/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Jamnagar
Class C and category b (i)
7 documents required · 7 mandatory
₹1,000
GE (AF) No 1 Jamnagar
₹1.1 L
Yes
3 Sept 2024
19 Jun 2024
19 Jul 2024
19 Jun 2024
17 Jul 2024
4 Jul 2024
Amount
M&L for Repair/Maintenance/servicing of ACB any capacity/type by cleaning the ACB by using air blower, tightening of connection/controls, checking of all fuses, sealing of ACB at bottom, repairing of ACB at bottom, repairing of mechanical parts, over hauling, oiling/greasing of all moving -parts and carrying out following checks for smooth functioning complete. (a) Visual Inspection (b) Checking of funtional locks, interlocks, signaling devices. (c) Checking of suitablility and correct operations of protections, control instruments and electrical connection of the circuit breaker operating mechanism. (d) Checking of Tripping Mechanism operation. (e) checking of standard voltage at PT. (f) Checking of breaker ON/OFF operation manually and electrically. (g) relay setting. (h) Checking of IR value of ACB. (I) Testing for proper funclity Note: (i) Major spare Parts if found unserviceable will be measured & paid separately as supply only as below and spare parts other than included in contract if reqd deemed to included in quoted rates for item no 1. (ii) Unserviceable parts shall be property of contractor as per credit schedule. (iii) Make approved as per OEM and compitible model shall be used only after approval of GE/Engr-in-charge.)
Supply only Neutral CTs for ACB 1000A (NCT) complete all as specified and as directed.
Supply only Under Voltage Trip Device (UVT) for ACB 415/220V AC complete all as specified.
Supply only spring charging motor for ACB 110V/230V complete all as specified and as directed.
Supply only shunt trip closing coil for ACB 220V/DC complete all as specified and as directed.
Supply only main CTs for ACB 1000/1250/1600A complete all as specified and as directed .
Supply only adaptor type terminal for 3 pole/4 pole ACB 1000/1250A complete all as specified and as directed.
Supply only adaptor type terminal for 3 pole/4 pole ACB 1600A complete all as specified and as directed.
Supply only door inter lock for LT ACB any capacity and make complete all as specified and as directed.
Supply only spring charging indication switch for ACB complete all as specified and as directed.
Supply only trip indication switch for ACB complete all as specified and as directed.
Supply only ACB 1000A 3 pole with micro processor release 50 KA draw out type complete all as specified and as directed.
Supply only ACB 800A 4pole with micro processor release 50 KA draw out type complete all as specified and as directed.
Supply only Earth fault relay for MCCB 400A complete all as specified and as directed.
Supply only Earth fault relay for MCCB 500A to 800A complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc alongwith disconnecting u/s XLPE cable any size and taking out including bricks/cable cover for protection, sand cushioning and stacking, removal to store for re-use or for credit, etc complete all as specified and as directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and as directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where as directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and as directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150mm x 40mm complete all as specified and as directed.
Laying only old un-reinforced precast concrete cable cover, flat, size 250 mm x 150mm x 40mm complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm 4 core aluminum conductor 1100 volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. (Note :-(i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.)
All as per Serial Item No. 22 here-in-before but 25 Sqmm 4 Core size.
All as per Serial Item No. 22 here-in-before but 35 Sqmm 3.5 Core size.
All as per Serial Item No. 22 here-in-before but 50 Sqmm 3.5 Core size.
All as per Serial Item No. 22 here-in-before but 70 Sqmm 3.5 Core size.
All as per Serial Item No. 22 here-in-before but 95 Sqmm 3.5 Core size.
All as per Serial Item No. 22 here-in-before but 120 Sqmm 3.5 Core size.
All as per Serial Item No. 22 here-in-before but 150 Sqmm 3.5 Core size.
All as per Serial Item No. 22 here-in-before but 185 Sqmm 3.5 Core size.
All as per Serial Item No. 22 here-in-before but 240 Sqmm 3.5 Core size.
All as per Serial Item No. 22 here-in-before but 300 Sqmm 3.5 Core size.
Supply and laying / fixing , GI pipe light grade 100mm dia bore for cable protection fixed to pole/wall or laid under floor/roadv /pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified and as directed. (Note: Boring of holes under road etc, shall be measured and paid separately.)
All as per item No 33 here - in before but GI pipe 80mm complete all as specified and as directed.
All as per item No 33 here - in before but GI pipe 50mm complete all as specified and as directed.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 2/4 core,16 to 25 Sqmm complete all as specified and as directed.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 35/50 Sqmm complete all as specified and as directed.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 70/95 Sqmm complete all as specified and as directed.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 120 to 185 Sqmm complete all as specified and as directed.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 240 to 300 Sqmm complete all as specified and as directed.
Disconnecting XLPE 3/4 core cable of any size from MCB/MCCB/Busbar chamber etc for repair /replacment job and reconnecting cable after replacing worn out /damaged copper alloy lugs, proper clamping, extended terminal link, repair to panel door replacement of door hinges, painting to disturbed surface complete etc complete all as specified and as directed.
Boring horizontally under roads/pavement/ hardstanding without disturbing the top surface by trench less technology using ultra sound technique and necessary machine including supply and fixing HDPE pipe of 90 mm dia(ISI Marked) suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and as directed. (Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost).
Supply and fix in repairs MCCBs 100 Amp, Four Pole, breaking capacity 16 KA, 415 V - 50 Hz, fixed thermal and Fixed magnetic setting type, fixed in existing panel & connecting complete all as specified & directed.
Supply and fix in repairs MCCBs 125 Amp, Four Pole, breaking capacity 16 KA, 415 V - 50 Hz, fixed thermal and Fixed magnetic setting type, fixed in existing panel & connecting complete all as specified & directed.
Supply and fix in repairs MCCBs 160 Amp, Four Pole, breaking capacity 16 KA, 415 V - 50 Hz, fixed thermal and Fixed magnetic setting type, fixed in existing panel & connecting complete all as specified & directed.
Supply and fix in repairs MCCBs 200 Amp, Four Pole, breaking capacity 35/36 KA, 415 V - 50 Hz, fixed thermal and Fixed magnetic setting type, fixed in existing panel & connecting complete all as specified & directed.
Supply and fix in repairs MCCBs 250 Amp, Four Pole, breaking capacity 35/36 KA, 415 V - 50 Hz, fixed thermal and Fixed magnetic setting type, fixed in existing panel & connecting complete all as specified & directed.
Supply and fix in repairs MCCBs 400 Amp, Four Pole, breaking capacity 35/36 KA, 415 V - 50 Hz, fixed thermal and Fixed magnetic setting type, fixed in existing panel & connecting complete all as specified & directed.
Supply and fix in repairs MCCBs 500/630 Amp, Four Pole, breaking capacity 35/36 KA, 415 V - 50 Hz, fixed thermal and Fixed magnetic setting type, fixed in existing panel & connecting complete all as specified & directed.
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, IP 55 protection ,cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted with PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with all accessories all as specified and as directed comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) Multifunctional digital type meter showing ampere, voltage PF phase to phase & phase to neutral. (iii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) Onload change over swtch 250A 4 Pole ( Incomming) (vi) MCCB 250 Amps,415V, 4 Pole, 35 KA - 01 No (Outgoing) (vii) MCCB 125 Amps, 415V, 4 pole, 35 KA - 03 Nos (Out going) (viii) MCCB 100 Amps, 415V, 4 pole, 35 KA - 01 Nos (Out going)
Note :- (a) Quoted rate includes excavation, earth work and PCC work and connection & testing complete. (b) PCC 1:3:6 platform with angle iron frame for mounting LT panel 1.2m above ground level, all as directed. (c) LT Panel should be mounted on platform of PCC (1:3:6) and supported by Angle sections complete all as directed.
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire Outdoor type , dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted with PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with all accessories all as specified and as directed comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) Multifunctional digital type meter showing ampere, voltage PF phase to phase & phase to neutral . (iii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) MCCB 250 Amps,415V, 4 Pole, 35 KA - 01 No (In coming) (vi) MCCB 63 Amps, 415V, 4 pole, 10 KA - 08 Nos (Out going)
Note :- (a) Quoted rate includes excavation, earth work and PCC work and connection & testing complete. (b) PCC 1:3:6 platform with angle iron frame for mounting LT panel 1.2m above ground level, all as directed .. (c) LT Panel should be mounted on platform of PCC (1:3:6) and supported by Angle sections complete all as directed by Engg-in- Charge.
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire Indoor type , dust proof front operated with adequate air ventilation at sides and back fabricated out of 2 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted with PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with all accessories all as specified and as directed comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) Multifunctional digital type meter showing ampere, voltage PF phase to phase & phase to neutral . (iii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) MCCB 315 Amps,415V, 4 Pole, 35 KA - 01 No (In coming) (vi) MCCB 160 Amps, 415V, 4 pole, 25 KA - 03 Nos (Out going) (vii) MCCB 100 Amps, 415V, 4 pole, 16 KA - 01 Nos (Out going) (viii) MCCB 63 Amps, 415V, 4 pole, 16 KA - 01 Nos (Out going)
Note :- (a) Quoted rate includes excavation, earth work and PCC work and connection & testing complete.( b) PCC 1:3:6 platform with angle iron frame for mounting LT panel 1.2m above ground level, all as directed . (c) LT Panel should be mounted on platform of PCC (1:3:6) and supported by Angle sections complete all as directed by Engg-in- Charge.
Material and Labour for renewal of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Note : The Quoted rate for above item includes the cost of following : - (a) Earth electrode. (b) Main earthing lead from earth electrode to test point of 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust, common salt and adequate quantity of chemical (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. (k) Test point. (l) Connecting lead from test point to main
M & L preparation of old steel suface over 10cm width or grith not otherwise described and applying a coat of synthetic enamal paint to LT feeder pillar box all as specified and directed .
M & L Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 (Gde E 165)
Material and labour in replacement for provision of earthing complete with copper earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to Copper strip 32 x 6 mm by means of bolts, nuts, check nuts and washer of copper, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation, earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note : (i) Earth result after installation completely should be less than 5 Ohm .(ii) Quoted rates shall be deemed to include for earth strip with protection pipe of 7.5 M length.
jagdish machinery stores
rajengineers
S t modi
SURESH ELECTRICALS
SohanandCompany
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .