| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.5 L+₹5.9 L (24.2%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | - | Rejected-Technical The firm is not enlisted in categary c(i) | |
| 4 | Rejected-Technical PLOT NO 127 3 A RATNASAGAR FLATS SECTOR 19 GANDHINAGAR 382019 | GANDHINAGAR | GANDHINAGAR | GUJARAT | 382019 | - | Rejected-Technical The firm is not enlisted in categary c(i) | |
| 5 | Rejected-Technical 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | - | Rejected-Technical The firm is not enlisted in categary c(i) |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
6 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) CHILODA
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
COMPREHENSIVE MAINT/ REPAIR/ REPLACEMENT OF COOLING APPLIANCES AT AF STATION WADSAR
2022_MES_524595_1
8812/2022-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
WADSAR
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹50,000
Yes
6 Aug 2022
17 May 2022
8 Jun 2022
17 May 2022
6 Jun 2022
31 May 2022
17 May 2022 - 30 May 2022
Amount
M & L for servicing/repairing, dismantling evaporative cooler (desert cooler) metal body carefully with removing grass pad and preparation of interior portion of cooler to smooth finish and applying one coat of bituminous paint and reassembling the same for smooth running complete all as directed. Note:- All Spare parts will be measured and paid separately under BOQ of respective items.
Supply and fixing in replacement following spare parts for Desert cooler:-
Fan blade PVC/ Metal for desert cooler of any size (as per sample ordered).
Grass pad/ Khas pad for desert cooler of any size (as per sample ordered).
Fan motor, single phase, 220 volts (as per sample ordered).
Cooler pump 240 volt (as per sample ordered).
Capacitor 4 MFD, MPP "SH".
Plug top 3 pin, 5 Amp.
PVC distributor three way superior quality.
PVC Eblow superior quality.
PVC flexible pipe superior quality heavy duty.
MS Wire Mess for supporting khas pad.
MS Legs as per sample.
Taking down carefully Window Type/ Split Type/ Cassate Type Air Conditioner/ Tower AC 1.50/ 2.00/ 3.00/ 5.5 Ton capacity, from its location and servicing/repairing for same and removing dirt and dust from interior and exterior of the Air Conditioner and washing the condensor and evaporator with clean solution and other areas by soap solution, spraying pressurised water on condensor and evaportor with proper protection of electrical fixtures and connection, drying the blowing air, and placing in same position Window Type/ Split Type/ Cassate/Tower Type Air Conditioner conditioner all as specified and directed by Engr-in-Charge. Note:- (i) Contractor will appoint technicians and helper for day to day complaint attending and servicing and cost of the same included in this item and nothing will be paid extra on this account. (ii) M&L for any spare part required for repair of ACs will be measured and paid separateley under respective items of BOQ.
Labour only for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoisturing the system and gas charging upto the required pressure for Air Conditioner/ Water Cooler/ Refrizerator/ Water Dispensor/ Deep Freezer complete all as approved and directed by Engineer-in-charge. Note:- The rate of Refrizerant will be paid under respective item of BOQ.
Dismantling and shifting the existing AC’s capacity 1.5/ 2.0 TR split type to new location including topping up of refrigerant complete all as specified and as directed. Note:- Copper pipe as required length will be measured and paid separately under BOQ.
Supply and fixing in replacement following spare parts for AC:-
Compressor suitable for existing split type AC 1.5 TR.
Compressor suitable for existing split type AC 2 TR.
Compressor suitable for window type AC 1.5 TR as existing type.
Condensor suitable for split type AC 1.5 TR.
Condensor suitable for split type AC 2.0 TR.
Window AC Fan and blower motor 1.5 TR.
Condensor motor suitable for split type AC 1.5/ 2.0 ton.
Condenser fan blade suitable for Window/ Split type AC 1.5/ 2.0 ton.
Running capacitor suitable for Window/ Split type AC 1.5/ 2.0 ton (Capacity as ordered)
Drain pipe PVC for split type AC any capacity minimum 1.5 Mtr length (as per sample)
Indoor unit complete suitable for 1.5 Ton Split Type Air conditioner complete (as per sample)
Circuit plate with PCB suitable for Window/Split type AC 1.5/2.0 ton.
Invertor PCB including remote control for remote sensing and operation.
Indoor blower motor for 1.5/ 2.0 ton split AC.
PVC air filter suitable for Window/ split type AC 1.5/ 2.0 ton.
Universal Remote control suitable for Split type AC 1.5/ 2.0 ton.
Swing motor suitable for Split type AC 1.5/ 2.0 ton.
Sealed compressor 3.0/ 3.5 TR Tower AC.
Compressor 5.5 TR suitable for 11 TR AC of existing size.
3 phase contactor relay for 3.5 ton AC.
3 phase starting relay for 3.5 ton AC.
Control PCB circuit for 3.5 TR.
Fan motor of suitable capacity for 3.5 TR.
Blower motor for AC 3.5 TR.
Fan blade for AC 3.5 TR.
PVC air filter for AC 3.5 TR.
Swing motor for AC 3.5 TR.
Control PCB cooling unit for 11 TR.
Power PCB condensor unit for 11 TR.
Fan blade 11 TR.
Blower motor for ODU unit for 11 TR AC.
Refrigerent gas any type (as ordered) for Split/ Window AC/ Water Cooler/ deep freezer/ Refrigerator.
Servicing/repairing of Refrigerator/ Deep Freezer 165 to 350 litres capacity including cleaning, checking of electrical connections etc. complete as in preventive maintenance all as specified and as directed. Note:- Replacement of compressor, spares, charging of gas, etc., if required shall be measured and paid separately under appropriate items of Schedule 'A' BOQ.
Supply only the following items/ parts for Referigerator/ Deep freezer any type and capacity as per sample:-
Thermostat Switch with knob.
Starting Relay Assembly with Over Load Protector.
Freezer Door complete including Bracket suitable for 175 ltrs capacity.
Freezer Door complete including bracket suitable for 310 ltrs capacity Refrigerator.
Aluminium Freezer Shell suitable for 175 ltrs capacity refrigerator.
Aluminium Freezer Shell 310 ltrs capacity refrigerator.
Plastic vegetable tray for any capacity refrigerator (as per sample ordered).
Condenser suitable for Refrigerator 175 ltrs capacity.
Condenser suitable for Refrigerator 286/ 310 ltrs capacity.
PCB Module 230 Volts, 50 Hz C/S suitable for Double Door Refrigerator.
Bimetal 230 Volts, 50 Hz C/S suitable for double door refrigerator.
Defrost Timer 230 Volts, 50 Hz C/S suitable for Refrigerator of 160/ 175/ 220 ltrs.
Cooling Fan Motor suitable for Double Door Refrigerator of 286/ 310 ltrs capacity.
Defrost timer suitable for Double Door Refrigerator capacity 286/ 310/ 350 ltrs.
Cabin bulb and holder for off sizes refrigeators.
Compressor suitable for refrigerator 165-180 ltrs.
Compressor suitable for refrigerator 310 ltrs.
Capillary tube for refrigerators.
Ice cube trays.
Bottle tray.
Egg tray.
vegetable tray.
Fridge vegetable tray cover plate.
Drain water sink try.
Drain water tub.
Cooling Fan Motor suitable for Deep Freezer 280/ 300 ltrs.
Material and labour for taking out the inner water tank of water cooler of any size and brazing/welding including applying compounds as required to stop leakage from the water tank, replacement of glass wool/toffed sheet, chicken wire mesh of appropiate thickness and spacing and stoppage of leakage in tubing (if any) around the tank and refixing as per oringinal pattern complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement following spare parts for Water cooler/ Water dispenser:-
Compressor suitable for water cooler 40/ 80 ltrs.
Compressor suitable for water cooler 150 ltrs.
Condensor suitable for water cooler 40/ 80 ltrs capacity.
Condensor suitable for water cooler 150 ltrs capacity.
Compressor suitable for water despensor.
Float valve suitable for water cooler 40/ 80 ltr capacity.
10 MFD capacitor for water cooler 40/ 80 ltrs.
Overload protection for water cooler 40/ 80 ltrs.
Starting capacitor suitable for water cooler 40/ 80 ltrs.
Starting relay suitable for water cooler 40/ 80 ltrs.
Fan motor 1/35 HP for water cooler 40/ 80 ltrs.
Fan blade for water cooler 40/ 80 ltrs.
3 pin, 15 Amp top plug, 240 Volts, single phase.
Stainless steel taps push button type, 15mm dia.
Supply only the following items/parts for Referigerator/ AC/ Water cooler/ Deep Freezer/ Refrigerator/ Water Dispensor/ Desert Cooler.
Copper tube 15 mm bore.
Copper tube 9.5 mm bore.
Copper tube 12.7 mm bore.
Copper tube 6.3 mm bore.
MCB SP 20-25 Amp.
Foam armour for AC copper tubing alongwith taping complete all as specified and directed.
Thermostat suitable for AC/ Water cooler/ Refrigerator any size and any capacity. Make:- Infass/ Rentora or equivalent make as approved by GE.
PVC insulated, 4 Sqmm, 3 core flexible round copper conductor.
PVC insulated, copper cable, 3 core, round of size 2.5 Sqmm.
PVC insulated copper cable 3 core round of size 1.5 Sqmm.
Metal clad Earth plug, 32 A, 3 Pole, 230 Volts, AC.
MCB TPN, 63 Amps, 4 pole, 'C' series.
AC enclosure box two pin and earth plug & socket complete with one SP MCB 20 amp.
M&L for rewinding of outdoor fan motor of 11 TR AC with super enameled copper wire of suitable gauge, varnishing including replacement of copper bushing and testing after connecting complete all as specified and as directed.
M&L for rewinding of indoor fan motor of 11 TR AC with super enameled copper wire of suitable gauge, varnishing including replacement of copper bushing and testing after connecting complete all as specified and as directed.
M&L for rewinding of fan motor suitable for 3.5 ton AC with super enameled copper wire of suitable gauge ,varnishing including replacement of copper bushing and testing after connecting complete all as specified and as directed.
S&F in reapair 230V, AC, 50Hz, 25 Amp with cyclic timer 3-999 minute programmable interval between two AC (programmeable alternate operation of AC-01 and AC-02) AC ON indication for AC-01 and AC-02 power on indication single phase and two input terminal etc complete all as specified and as directed. Make:- L&T or equivalent make as approved by GE.
S&F in replacement of old rusted AC mounting bracket with new 24 inch heavy duty wall mounted bracket load bearing capacity upto 50 kg complete all as per the direction of Engr-in-charge.
S&F Display panel in replacement for Chiller Unit 80 TR. Make:- Voltas or equivalent make as approved by GE.
S&F in repair for Filter Unit for AHU complete all as specified and as directed.
Comprehensive annual maintenance for (80x3 = 240 TR) Scroll type refrigeration Compressor with R407c refrigerant with Microprocessor panel and suction and Discharge valves, mono block pump for chilled water and condenser water any capacity, including draft type 160 TR cooling tower including all valves and pipes complete, Air handling unit of capacity from 14 to 38 TR, ceiling suspended unit of capacity from 1.8 to 8.5 TR, fresh air louvers with bird screen and heater bank of capacity from 3 to 18 KW, Pan humidifier of capacity from 1. 5 to 2.0 KW and complete power system supply of the AC Plant including sub panels complete all as specified and as directed by the Engineer-in-Charge.
SCOPE COVER UNDER AMC:- (i) Check oil level in the compressor. (ii) Check liquid sight glasses to determine if there is a refrigerant shortage. (iii) Inspecting the unit for leaks with a soap solution. (iv) Inspect entire system for any unusual conditions such as noise, vibration, etc. (v) Check the system operating pressure and temperatures to ensure proper operating conditions. (vi) Check Evaporator and condenser approach. (vii) Check chilled water flow by checking pressure drop across the chiller.
(viii) Compare the chilled water temperature at full load with the chilled water temperature control. (ix) Inspect all safety controls and adjust if required. (x) Inspect all operating control and sequence of operation. (xi) Review daily operating log maintained by Customers operating personnel and instruct operating engineer as required. (xii) Topping of Refrigerant and Oil if required under normal wear and tear. (xiii) Yearly health report of the chiller and suggestions for improvement. (xiv) Yearly Condenser water analysis. (xv) Motor Insulation Checks. (xvi) Yearly adjustments of controls if required.
AMC agency will arrange require tools for attend routine services/ minor breakdown call like an adjustable spanner, clamp meter, pressure Gauge with charging line, Digital Temperature gun, leak detector,`ring/ fix spanner set, Allen key set, screw driver set, motor insulation meter, software support if require. (Air blower & cotton waste provide by agency during routine service). AMC agency will also arrange require equipment’s for attend major breakdown call like as a vaccum pump, Digital Vaccum gauge, Refrigerant recovery unit, Empty refrigerant cylinders, dehydration tank, and require spanners.
Note:- (i) Refrizerant will be paid under respective item of BOQ (ii) AMC will covered all spares like as electrical, mechanical (motor), control, hardware & software.
Periodical inspection and service of the plant Water cooled scroll Chillers (80 x 3 = 240 TR, VOLTAS) once in a quarter as detailed below : (a) Inspect and check the machines performance once in three months. (b) Check refrigerant leakage of the machines. (c) Rectify the system defect causing leakage. (d) Carry the proper functioning of microprocessor and take the control test. (e) Check the electricla components and terminals for proper tightness.
(f) Clean electrical panel periodically. (g) Check functioning of water flow switch and interlock in the system. (h) Check all safety controls for proper functioning and replace if the same is defective. (j) All the breakdowns including compressor failure will be attended. (k) Check refrigerant filter and drier core, replace the same, if found necessary. (l) Supply of electrical parts expect electrical spares for incoming panel. (Like fuses, incoming electrical controls, cables etc.
Monthly inspection and service of the chilled water pump, condenser pump (10 x 3 = 30 Hp) as detailed below: (a) Check the alignment and conditions of coupling to prevent damage to shaft and impeller. (b) Lubricate bearings with grease guns. (c) Replace gland thread if required. (d) Check lubricant oil level and make up the oil if required. (e) Check packing and mechanical seals for leakage.
Half yearly inspection and service for pumps as detailed below:- (a) Inspect shaft sleeves,shaft, bearings, bearing housing and overhauling of all pumps. (b) The impeller and shaft to be repaired and made functional. If they are found not repairable, then same will be replaced. (c) The packing, mechanical seal, bush, bearing, shaft sleeves, coupling etc. If found faulty to be replaced by the contractor with out any extra cost.
Monthly inspection and service of the cooling tower:- (a) Check cooling tower water being circulated for the suspended particals, algae formation, if find so refill the circuit with fresh water. (b) Check cooling water being circulated for the hardness as in PPM. If it is more than 150 PPM, blow down water partially and make up with fresh soft water. (c) Drain the water and clean the sump of cooling tower. (d) Clean pot stainer/ Y-stainer. (e) Check the condition of fills, if required, clean the fills with detergent. (f) Check for operation of shut off valves.
ALBA AC AND REF SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .