| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC D 89 SHASTRI NAGAR MEERUT UTTAR PRADESH PIN 250004 | MEERUT | MEERUT | UTTAR PRADESH | 250004 | L1 | Accepted-AOC AOC accepted. | |
| 2 | L2₹35.8 L+₹1.2 L (3.54%)Rejected-AOC 31 SARASWATI SONI MARG DEHRADUN | DEHRADUN | L2 | Rejected-AOC AOC rejected. | |
| 3 | L3₹36.8 L+₹2.2 L (6.45%)Rejected-AOC H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC AOC rejected. | |
| 4 | L4₹41.0 L+₹6.4 L (18.6%)Rejected-AOC 37 2 INDIRA COLONY CHUKHUWALA DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC AOC rejected. | |
| 5 | L5₹42.7 L+₹8.2 L (23.6%)Rejected-AOC | L5 | Rejected-AOC AOC rejected. |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
17 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Provn of sig centre for 69 Mtn Bde Sig Coy at Ghunghora under GE Dehradun.
2022_MES_548191_1
8528/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE Dehradun
Class D cat a (i)
8 documents required · 8 mandatory
₹500
Yes
GE Dehradun
₹87,200
Yes
6 Dec 2022
27 Aug 2022
19 Sept 2022
27 Aug 2022
17 Sept 2022
10 Sept 2022
Amount
Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out in any type of soil complete all as specified and directed.
M&L returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soil complete all as specified and as directed.
Removal of excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L Hardcore of broken stone aggregate of gauge exc 40mm but n exc 63mm deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed.
Surface excavation in any type of soil n. exc. 30 cm deep and averaging 15 cm deep and getting out complete all as specified.
M&L Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat fair finished surfaces of concrete complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed.
All as per item No 10 here-in- above, but 6mm to 8mm dia bar complete all as specified.
All as per item No 10 here-in above 5mm dia and over upto and including 10mm dia bar in stirrups, spacers and binders complete all as specified.
M&L for Reinforced cement concrete 1:1.5:3 (nominal mix) type A1 (using 20mm graded stone aggregate) in foundations, incl rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as spefied and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular or polygonal for fair finished surfaces of concrete complete all as specified and directed.
M&L for Reinforced cement concrete 1:1.5:3 (nominal mix) type A1 (using 20mm graded stone aggregate) in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam aunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. flat fair finished surfaces of concrete complete all as specified and directed.
M&L for Reinforced cement concrete 1:1.5:3 (nominal mix) type A1 (using 20mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat fair finished surface of concerte complete all as specified and directed.
M&L for Reinforced cement concrete 1:2:4 (nominal mix) type B0 (using 12.5 mm graded stone aggregate) in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items in cluding edges, flat fair finished surface of concrete complete all as specified.
M&L for Reinforced cement concrete 1:1.5:3 (nominal mix) type A1 (using 20mm graded stone aggregate) as in Chajjas etc complete all as specified and directed.
M&L for 40mm Damp proof course in cement concrete 1:2:4 type B0 ( using 12.5mm graded stone aggregate) to horizontal or vertical surfaces mixed with integral water proofing compound as per manufacturer instructions including necessary formwork complete all as specified and directed. Note :- Water Proofing Compound shall be measured and paid seperately.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) complete all as specified.
M&L for Brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 finished fair and even without using extra cement complete all as specified and directed.
M&L 15 mm thick rendering in cement mortar 1:4 on other than fair faces of brick work or concrete surface, surface finished even and fair without using extra cement complete all as specified.
Supply only Liquid water proofing compound as per manufacturer instructions complete all as specified.
M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement complete all as specified
M&L for PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate), 75 mm thick as in sub base complete all as specified and as directed.
M&L 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate as in leveling course to floors etc complete all as specified
M&L for PCC (1:3:6) type C-2 (using 20 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in surface channels and drains including moulds if required complete all as specified and directed.
M&L vitrified ceramic coloured tiles 10 mm thick (square/rectangular) polished,area of each tiles not exceeding 0.36 sqm, in floor etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified.
All as per item No 33 here in above but as in skirting over and including 10 mm thick rendering in cement mortar 1:4, complete all as specified.
M&L non skid / mat finish ceramic colour tiles of size 300 mm x 300 mm and 7-8 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified.
M&L heavy duty endura ceramic coloured parking tiles 10 mm thick dark shade (square/rectangular) polished,area of each tiles not exceeding 0.36 sqm, in floor etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 and complete all as specified.
M&L glazed ceramic colour tiles size 300 mm x 450 mm x 6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified.
S&F aluminum alloy powder coated door made out of hollow extruded aluminum section as mentioned below. Each door having 02 Nos Disc or D type handle, 02 Nos aluminum tower bolt 200 mm size, one brass mortice lock of six lever with key in duplicate regulated by double action hydraulic floor spring heavy duty (Make:- Sandhu/Ritz) shutter to be partly glaze with 5mm thick tined coloured glass in upper pannel and partly pannelled with 12mm thick both side laminated particle board in lower pannel fixed with glazing clip, rubber beading/gasket, anodised aluminum beading screw complete all as specified and directed at site. Chowkhat Frame:- 101.60x44.45x1.60mm Shutter verticle style :- 85x44.45x1.56mm shutter middle Rail :- 83.50x44.45x1.54mm Shutter Top Rail and bottom Rail :- 114.30x44.45x1.55mm. Make: (i) Anodised aluminum section : Jindal / Hindalko / Indalco. (ii) Particle board: Navipan / Puratuff / Kitlam (iii) Glass: Saint gobain / Modi guard / Tata
S&F powder coated Aluminium partition (Fixed) made out of aluminium powder coated section 83 x 44.45 x 2.00 mm including 5 mm thick glass/ACP Sheet complete with rubber packing/aluminum beading etc complete all as specified and directed. Make: (i) Anodised aluminum section : Jindal / Hindalko / Indalco. (ii) Particle board: Navipan / Puratuff / Kitlam (iii) Glass: Saint gobain / Modi guard / Tata
S&F aluminum alloy powder coated standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter and one nos wire gauged shutter sliding type, with aluminum sections as per Series-A(15mm) 3 track of Jindal section numbers for sliding windows, and glazed with tinted glass coloured glass 4mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum tower bolt 150mm long etc complete all as specified and directed. Shutter Top & bottom size : 37.50x15x1.60mm Shutter inner lock size 37.50x15x1.60 mm Shutter side (Handle) size 37.50x15x1.36 mm Chowkhat bottom size : 50.30x26x1.20mm Chowkhat top & sides size: 50.30x26x1.00mm. Make: (i) Anodised aluminum section : Jindal / Hindalko / Indalco. (ii) Particle board: Navipan / Puratuff / Kitlam (iii) Glass: Saint gobain / Modi guard / Tata
M&L for 60 mm thick pre polished rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment complete all as specified and directed by the Engr-in-Charge.
M&L mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, ball bearing and other similar works etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding conforming to Fe-290 (Gde- E165) complete all as specified
S&F factory made 100 % solid wood plastic composite (WPC) door frame 75x50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing as directed by Engineer-in-Charge
S&F 30 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side palin with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire etardant and having screw holding capacity complete all as specified.
S & F factory made steel ventilator with top hung shutters including hinges with steel handle, steel peg stay, tower bolt etc.complete all as specified.
S&F Stainless steel wire cloth 0.56mm nominal dia of wire with 304 grade nickle and average width of aperture 1.40mm and fixed with stainless steel wire staples all as directed by Engineer- in -Charge.
S&F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified.
M&L preparation of new steel surfaces over 10 cm width or girth of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S & F stainless steel barrel tower bolts Gde- 204, 150 mm long one piece and fixed complete all as specified.
S & F stainless steel butt hinges, medium weight Gde-204, 100 mm long one piece and fixed with screws/welded to frame ,complete all as specified
S & F stainless steel handles Gde-204, 150 mm long one piece and fixed with screws/welded to frame ,complete all as soecified.
M&L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410 -W (Gde-E- 250) quality-A complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and profile should match with galvalume sheet complete all as specified and as directed..
Providing & fixing false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 2mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, complete at all heights as per direction of Engineer-in-Charge.
S&F vitreous china wash down water closet Padestal pattern white (excluding flushing cistern and fluch pipe) with CI 'P' or 'S; trap including plastic white seat cover, CP Jet spray with 1.0 mtr long PVC pipe, connecting to stack pipe and to flushing pipe and complete including making good to floor complete all specified and directed.
S&F 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including brackets with 32 mm dia PVC pipe/bend 600 mm long complete. Hindware/Parryware/Jaquar.
S&F vitreous china wash hand basin including brackets, white size 550 x 400 mm incl cutting cutting for and pinning in ends of brackets. Including Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed
S&F pillar taps, brass, with capston heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed. Make : Jaguar/Cat part No. KUP-35001PM/Hindware Cat Part No:F370001/Parryware Cat Pat No.T4302A2
S&F vitreous china urinal flat back of size 360 x 330 x 740 mm, white including grating and union for discharge pipe but excluding flushing cistern, flush pipe and waste pipe and including CP bottle trap fixing plugs beading urinal against wall in CM 1:2, securing urinal to plugs with brass screws 60 mm long, pointing around urinal in white cement and fixing union for discharge specified and directed.
S&F rotational moulded polyethylene water storage tanks of capacity 1000 litres tripple layer, white colour, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 complete all as specified.
S&F ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 20 mm bore size (Minimum weight 210 gms) complete all as specified.
S&F 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 15 mm bore Angle cock/stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. Make : - JAGUAR Cat Part No FON-40053/Hindware Cat Part No F160017/Prayag Cat No 9410
S&F 15mm bore Bib taps long body cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. Make : - JAGUAR CAT Part No ALI-85037/Hindweare CAT Part No F-370004/Prayag CAT Part No S9906
S&F CP grating 100mm to 125 dia round fix on floor/ nahani trap with hole/without fixed with cement mortar, complete all as specified and directed.
S&F fancy type 5.50mm thick looking mirror with PVC moulding 40mm wide all around with back 5mm thick PVC board of size 450mm x 600mm as approved by Engr-in-Charge.
S&F 20 mm dia brass chromium plated towel rack of 3 sets type 60cm long between flanges including pair of fixing brackets complete all as specified and directed. Make: Jaquar Cat Part No AKP-35781PS/CAN-1181FHS or equivalent in Parryware/ Hindware
S&F PVC connection 15 mm dia 450 mm long with brass fly nut at both ends complete all as specified
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Supply, fixing, laying & testing 20mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for preparation of plastered surfaces wall and applying wall putty 1 to 1.5 mm thick, and rubbing with sand paper to make the surface smooth complete all as specified.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified in SSR Part I and directed by Engr-in-Charge.
M&L for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified
S&F 150mm internal dia salt glazed stoneware drain pipe Gde 'A', laid in trenches and jointed in cement & sand mortar 1:1, complete all as specified and directed.
M&L for 60 mm thick vibromatic reinforced precast cement concrete 1:2:4 (using 20mm graded stone aggregate) with 1mm thick mild steel CR sheet around painted with 2 coats of bituminous paint , as in man hole cover slabs finish fair even and smooth without using extra cement ( Top surface will be chequred finish) including necessary form work, 100 mm long handle of 12mm dia round bar counter sunk by 25mm welded to reinforcement complete all as specified and directed by Engr-in-charge (Note : (i) CA No and date will be engraved on covers. (ii) Reinforcement shall be measured and paid saperately. (iii) Curing will carried out with ponding method)
S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls/floor etc complete all as specified and directed.
S&F PVC (SWR) pipes of 75 mm dia, single socketed fixed to walls/floor etc complete all as specified and directed.
S&F PVC (SWR) pipes of 110 mm dia, bend with oval acess door, T' socket reducer etc complete all as specified and directed.
S&F PVC (SWR) pipes of 75 mm dia, bend with oval acess door, T' socket reducer etc , complete all as specified and directed.
S&F Stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, incl nut and bolts and securing ends of stay to wall or roof for 100 mm bore CI pipe.grouted in PCC 1:2:4 complete all as specified.
S&F Stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, incl nut and bolts and securing ends of stay to wall or roof for 75 mm bore CI pipe.grouted in PCC 1:2:4 complete all as specified.
Cutting into existing manholes for connecting new drains 150mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete al as specified and directed.
M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and othe similar bands, plinth courses, bed plates, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork all as directed by Engineer-in-charge.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20/25 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of following. Note: The wiring to be done as per IE rule and maintain colour code accordingly.
One light point point /bell buzzer point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
All as per item No 85 here-in- above but one 3 pin socket outlet 15 Amp independent, cable 2.5 Sqmm Pvc insulated unsheathed multistranded copper cable FRLS for phase & neutral, with 2.5Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS as earth continuity conductor.
All as per item No 85 here-in- above but up to Sheet matel enclosure MCB DB with plug socket independent, with cable 4 Sq mm size, with earth continuity coductor of size 4 Sq mm.
S&F sheet metal enclosure SPN with 3 pin earth metal plug and socket complete with one SPN MCB 20 Amps, 240 volts in repairs complete all as specified and directed by Engineer-in-Charge. Make L&T, ABB, Legrand, GE
S&F sheet metal enclosure Triple pole and earth with a three pin and earth plug with socket complete with one triple pole MCB 63 Amps, 415 volts in repairs complete all as specified and directed by Engineer-in-Charge. Make L&T, ABB, Legrand, GE
M&L sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC concealed conduit heavy duty accessories and fittings. PVC insulated unsheathed FRLS cable copper conductor multistranded of size 6 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. (Note: Two run of 10sqmm and one run 6 Sqmm and one run condiut with accessories shall be measured as one run).
M&L sub main wiring with 4 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sqmm. (nominal area) drawing in and including 32 mm. dia higher PVC concealed conduit heavy duty accessories and fittings. and one single core green colour PVC Insulated unsheathed FRLS cable copper conductor multistranded of size 2x6 Sqmm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. (Note: Four run of 10sqmm and two run 6 Sqmm and one run condiut with accessories shall be measured as one run).
M&L sub main wiring with 4 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 16 Sq.mm. (nominal area) drawing in and including 32 mm. dia higher PVC concealed conduit heavy duty accessories and fittings. and one single core green colour PVC Insulated unsheathed FRLS cable copper conductor multistranded of size 2x10 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed (Note: Four run of 16sqmm and two run of 10 Sqmm and one run condiut with accessories shall be measured as one run).
M&L sub main wiring with 4 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 25 Sq.mm. (nominal area) drawing in and including 32 mm. dia higher PVC concealed conduit heavy duty accessories and fittings. and one single core green colour PVC Insulated unsheathed FRLS cable copper conductor multistranded of size 2x16 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed (Note: four run of 25sqmm and two run 16 Sqmm and one run condiut with accessories shall be measured as one run).
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete al as specified.
S&F step type regulator socket type double module 5 step for ceiling fan 230 volts 6 Amp.
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC.
M&L lamp holder insulated body with back plate suitable for angle and batten fitting complete all as specified.
Supply only copper flexible wire hoisted twin cord 23/0076 for connection of ceiling fan etc. complete all as specified. Make :- Finolex/Ploycab/Kalinga.
All as per item No 101 here-in-above but 40/0076 tube light connection etc. Make :- Finolex/Ploycab/Kalinga.
Supply only PVC insulated copper cable of size 40/0.0076 multi standard 3 core. Make Plaza, National, RR Kabel, Shalimar.
S&F sheet metal enclosures Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 200 Ams rated bus bar & one MCCB 100 Amp as incoming and 12 MCB SP as outgoing complete all as specified and directed.
S&F sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed.
All as per item No 105 here-in-above but 12 way DB,s.
All as per item No 105 here-in- above but 4 way DB,s.
S&F MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed.
S&F MCB single pole, 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed.
S&F MCCB 200 Amps 36 KA 4 pole 415 V AC 50 Hz thermal-magnetic release Ics=100%of Icu .
S&F MCCB 415 Volt 16 KA 4 pole 125 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed. Make: Legrand/Schneider/Simens/L&T
Supply, Fixing & Connecting wall mounted fan oscillating type 400mm sweep single phase 230 Volt complete all as specified and directed.Make :- Havells/ Crompton/ Usha
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm, 900 RPM, single phase, 230V AC with louver all as specified and directed 30 mm sheet. including connection with twisted white three core flexible copper multistranded conductor cabl from ceiling rose to connector all a directed by Engineer-in-charge.
S&F ceiling fan 1200 mm sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc BEE 5 star rated including connecting with twisted three cord flaxible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan comlete all as specified and directed.
M&L GI bracket made out of 40 mm GI pipe medium grade bend for fabrication to shape as required length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps 02 Nos not less than 50x6 mm MS flat duly painted, nuts, bolts and washer complete all as directed. (Make - TATA/JINDAL/Swastik).
Supply and Fixing Integral LED Bldg security Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 40/45 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed. Make:- Crompton model No. LSTP-45-CDL/Havells model No. ENDURAPEARLNEOSL 40WLED757PASYTOPC /Philips Cat Part No BRP409LED CW036MRFGIPSUGRand syska SSK-ST-40W.
S&F wall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten) and MAS LE$D 1200mm 18W-865-T-81 (Tube) / Wipro Cat part No WI0922208 (Tube Batten) LL13-181-65SE (Tube)/ Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS (Tube Batten)CRYSTAL1213T8DSTL20WLED865SGLASS(TUBE DOUBLE SIDE)
Supply, Fixing and testing LED down lighter recessed mounted 2x2 feet 36W ultra modern designed LED luminaire which provide soft light and glair free symmetrical illumination suitable for grid ceiling and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on as per Havells Cat Part no: ENDURASLIMPROPLUS2x2PLR28/36WLED 840MOD or equivelent make of PHILIPs/ CROMPTONall as directed by Engineer-in-Charge.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and as directed.
M&L for earthing with copper earth plate of size 60cm x 60cm x 3 mm thick electrode burried directly in ground to a depth not less than 2.25 mtr and top edge of the plate not less than 0.5 mtr below ground level with adequate quantity of charcoal dust and common salt to a packed thickness not less than 15 cm on all side of earth plate including necessary excavation, earth work in any type of strata, returning re-filling in and removal of surplus strata to a distance not exc. 50 mtr including copper strip 32 x 6 mm earth strip duly soldered,/brazing and rivetted to earth plate at one end including all joints and connected to terminal block to GI clamping with GI nuts, bolts, washers and providing GI 40 mm dia medium grade GI pipe from earth plate to terminal block above ground level for watering pipe arrangement 20 GI light grade shall provide upto earth electrode GI funnel,with wire mesh shall be provided on the top of this pipe PCC 1:3:6 type C1 CI chamber RCC 1:2:4 type B1 for earth pit cover with 6 Nos 8mm dia high strength deformed steel TMT bars on both ways 10mm dia TMT bar shall be provided as in handle for lifting the slab complete all as shown in electrical plate No 3 of SSR part-I 2009 including testing on completion all as directed. Note:- (i) If the desired earth resistance is not found within permissible limit shall be redone by the contractor at no extra cost. (ii) Cost of copper strip and 25mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item).
S&F aluminium strip 25x3mm fixed in ground,on wall, pole with epoxy based insulator for down conductor including drilling two Nos holes at each joint, one set of lead washers between strips two sets GI nut, bolt, washers one set of lead washers between strips two sets GI nut, bolts, washers gutties, screws etc complete all as specified.
S&F air termination single pointed aluminium rod of 12mm dia 300mm long fixed to aluminium strip 25x3mm drilling nuts, bolts washers for resting/supporting of air terminals etc complete all as directed by Engineer-in-Charge.
M&L for Cutting and screwing existing steel tubing for alterations or additions (Each cut measured) pipe making connection of GI Pipe distribution branch with GI main of size 16 to 40 mm bore complete all as directed.
Supply, Laying, fixing & testing galvanished iron water tubing 'medium grade; 20 mm dia with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducing bends , elbows, tee, checkneuts, caps, plugs etc laid in trenches for the following sizes complete all as specifed and directed. Note: Excavation and earth work shall be measuered and paid seperately under respective item of schedule 'A"
All as per item No. 125 here-in- above but 'medium grade; 40 mm dia with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducing bends , elbows, tee, checkneuts, caps, plugs etc
Supply, laying, jointing and testing of underground XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 4 Core laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs of cable size all as specified and directed.
Supply and laying in trenches fixed to poles wall laid in floor GI steel tubing light grade 50 mm bore with fitting GI clamps made out of 50 x6mm flat iron 02 Nos, bolt, nut & washers etc or wooden rubber bushing at the ends of complete all as specified and directed.
M&L for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed.
Supply & Laying well burnt bricks, sub class 'B' brick laid breadth wise, along the cable in trenches after sand cushioning laid for protection of UG cable protection complete all as specified and directed.
M/s RP AGRAWAL
M/s Pradeep Kumar
AYUSH CONSTRUCTION COMPANY
M/S C S AITHANI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .