Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC AT GIDI A NEAR TREKKAR STAND RELIGARA PO GIDI A DIST HAZARIBAGH | GIDI A | HAZARIBAGH | L1 | Accepted-AOC AWARDED | |
| 2 | L2₹13.4 L+₹99,865.56 (8.05%)Rejected-AOC AT PO RAJRAPPA PROJECT DIST RAMGARH JHARKHAND 829150 | RAMGARH | RAMGARH | JHARKHAND | 829150 | L2 | Rejected-AOC FINANCIALLY REJECTED | |
| 3 | L3₹14.7 L+₹2.3 L (18.7%)Rejected-AOC AT PO CHITARPUR DIST RAMGARH JHARKHAND 829150 | CHITARPUR | RAMGARH | JHARKHAND | 829150 | L3 | Rejected-AOC FINANCIALLY REJECTED | |
| 4 | L4₹15.7 L+₹3.3 L (26.7%)Rejected-AOC CHITARPUR DISTT RAMGARH CANTT JHARKHAND 825101 | CHITARPUR | RAMGARH | JHARKHAND | 825101 | L4 | Rejected-AOC FINANCIALLY REJECTED |
Tender Value
₹21.4 L
EMD Value
₹26,800
Closing Date
7 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM
SO EnM OFFICE RAJRAPPA
Extension/ erection n Dismantling of HT Overhead Line of 3.3KV n 6.6KV of feeder No.- 6,7, 22 n 24 (Route length for erection apprx.2340 mtr and for dismantling apprx. 1140m) for the period of 01 year on as, when and where required basis at mines
2024_CCL_306987_1
SO(EnM)/Rjp/24-25/Et/13dt 25.4.24
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
RAJRAPPA
Please refer Tender documents.
2 documents required · 2 mandatory
₹26,800
14 Aug 2024
26 Apr 2024
8 May 2024
27 Apr 2024
7 May 2024
27 Apr 2024
27 Apr 2024 - 30 Apr 2024
Amount
Erection of metallic pole of length Above 11 metre and upto 12 metre in cement concrete 1:3:6 (1cement: 3 coarse sand: 6 graded stone aggregate 40mm size) foundation including excavation and re filling etc.as required
Labour cost for loading, unloading of metallic poles, conductor etc.for transportation from store to site (vice versa).(Truck will be provided departmentally)
Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required..
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Erection of angle iron/ channel iron cross arm on steel tubular/ rail pole etc. as required.( For conductor bracket= 31*2 =62 and cradle guard bracket =21)
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Erection/ Tensioning of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required.(Approx. Route length for erection is 2340m).
Erection/ Tensioning of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required. (Approx. Route length for erection is 2340m).
Supply of 8 SWG GI Wire for cradling
Erection of Cradle guard 3 wire(15 no of spans)
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Total impact of GST for the purpose of CTC
Coalfield Construction
RK CONSTRUCTION CHITARPUR
techsummary_318164.pdf
PDF • 0.19 MB
finsummary_318164.pdf
PDF • 0.19 MB
Uday203.pdf
PDF • 1.98 MB
finance_318164.pdf
PDF • 0.02 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .