Loading…
Loading…
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Jun 2026, 6:00 pm
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR / MAINT OF STREET / SECURITY / HIGH MAST / GARDEN LIGHTS AND POST TOP LANTERNS AND REPAIR / MAINT OF DG SETS AT INS EKSILA UNDER AGE E/M NO-III OF GE(U-I) VISAKHAPATNAM
2026_MES_769737_1
8858/E8
Open Tender
Electrical and Maintenance Works
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Utility-I
₹90,000
Yes
4 Jun 2026
4 Jun 2026
27 Jun 2026
4 Jun 2026
25 Jun 2026
19 Jun 2026
S&F LED street light fitting of capacity 60 watt, 230 V, AC outdoor type with high pressure die cast aluminum housing and heat resistant, toughened glass cover including thermal management in multiple optics, high efficiency electronic driver, operating Voltage range 140 to 270 V, IP-66 (minimum) protection, integrated type, inbuilt SPD of capacity not less than 4 KV and including electrically connecting suitable for pole dia up to 54 mm (max) & taking down old unserviceable street light fittings complete all as specified and as directed.
All as per serial Item No. 2.00 herein before but LED street light fitting of capacity 90 W
All as per serial Item No. 2.00 herein before but LED street light fitting of capacity 100 W
All as per serial Item No. 2.00 herein before but LED street light fitting of capacity 120 W
S&F LED flood light fitting of capacity 100 watt, 230 V AC outdoor type, IP-66 (minimum), environment friendly with operating Voltage range 140 to 270 V, inbuilt SPD of capacity not less than 4 KV, pressure die cast aluminium housing, toughened glass cover with thermal management in multiple optics, with impact and corrosion resistant complete with driver and lamp, internally prewired and including electrically connecting & taking down old unserviceable flood light fittings complete all as specified and directed.
All as per serial Item No. 6.00 herein before but LED flood light fitting of capacity 120 W
All as per serial Item No. 6.00 herein before but LED flood light fitting of capacity 170 W
All as per serial Item No. 6.00 herein before but LED flood light fitting of capacity 210 W
S&F Post top lantern LED type 20 watt, 230 volts AC outdoor new generation type with energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LED's as light source with IP-65 (minimum) including electrically connecting and taking down existing unserviceable post top lantern complete all as specified and directed.
All as per serial Item No. 10.00 herein before but LED Post top lantern of capacity 40 W
S&F cylindrical shaped LED Bollard type, 10 W with IP 66 protection to ensure sustainable performance in all sections and aesthetics which keeps the surrounding lively including base stand alone, connecting and commissioning & Taking down existing unserviceable Bollard light fittings complete all as specified & directed.
S&F Round shaped LED Garden light, 36 W with IP 65 protection to ensure sustainable performance in all sections and aesthetics which keeps the surrounding lively including base stand alone, connecting and commissioning & Taking down existing unserviceable Garden light fittings complete all as specified & directed.
S&F Square shaped LED Garden light, 40 W with IP 65 protection to ensure sustainable performance in all sections and aesthetics which keeps the surrounding lively including base stand alone, connecting and commissioning & Taking down existing unserviceable Garden light fittings complete all as specified & directed.
M&L for bracket suitable for street light made out of GI pipe light grade of 40 mm bore & 1.20 mtr length (minimum), bend to shape including 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers etc, & painting the bracket with two coat of aluminium paint over a coat of red oxide primer including taking down existing un-serviceable bracket complete all as specified and directed.
S&F PVC insulated 3 core multistranded sheathed FRLS grade cable with 1.5 Sqmm copper conductor for connecting junction box to of street / security light etc. and including 20 mm bore dia PVC conduit and including taking down existing un-serviceable cable and condute of any description complete all as specified and directed by Engineer-in-Charge.
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 10 Sqmm x 4 Core, laid in trenches / duct / on pole including taking down existing unserviceable cable complete all as specified and directed.
All as per Sl item No. 17.00 herein before but cross sectional area 16 Sqmm x 4 Core
All as per Sl item No. 17.00 herein before but cross sectional area 25 Sqmm x 4 Core
All as per Sl item No. 17.00 herein before but cross sectional area 35 Sqmm x 4 Core
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with clean and dry river sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness of sand coushioning shall only measured and paid.
Supply & laying sub class 'B', class designation 75 bricks of old size, laid over sand cushioning along alignment of cable as protection to cable in trenches including taking out existing bricks complete all as specified and directed. Note : Sand cushioning will measured and paid separately.
S&F steel tubular swaged poles conforming to IS-2713, complete with cast iron base plate, finial taper plug, bolts, nuts & screws, type 410 SP-31 (9 m long) and including painting with two coat of aluminium paint over a coat of primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and 03 Nos band / strips with white synthetic enamel paint, 30 cm wide each at a distance of 30 cm from top of plinth block and numbering of poles including taking down existing unserviceable pole including demolition of coping and foundation complete all as specified and directed. Note:- Excavation, earth work and PCC work will be measured and paid for separately under respective items.
M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L PCC (1:2:4) type B1, (using 20 mm graded crushed stone aggregate) as in copings, benching and the like etc. including necessary formwork & demolotion of old concrete complete all as specified and directed.
M&L for cutting the tarmac / hard standings in road and excavating trenches across the road in size not exceeding 0.45 m wide and 0.6 m depth for laying cable / cable protection pipe including refilling earth & making good top surface of the disturbed portion with 100mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) / bituminous mix as per existing & matching with the surroundings including removal of rabbish off to distance not exceeding 100 m complete all as specified and directed. Note:- Unit rate quoted against this item shall deemed to include cost of road cutting, earth work excavation, plain cement concrete work required for making good top of the surface, complete.
S&F 40 mm bore dia galvanised steel tubing, light grade galvanised, laid under road crossing, for cable protection or fixed to poles, walls or laid under floors including taking down existing un-serviceable pipe of any description complete all as specified and directed.
All as per Sl Item No. 30.00 here in before but 50 mm bore dia
M&L for Taking down existing loop in loop out junction box, disconnecting the cable connections and refixing the same loop in loop out junction box with new cable connections including providing new set of aluminium lugs thimbles of size 10 to 35 sqmm (as reqd) for 3.5/4 core existing LT cable of any type, necessary insulation with tape, clamps for fixing of cables, fittings and fixtures, nut bolts etc complete all as specified and directed.
M&L for disconnecting electrical connection of defective / burnt out UG LT cable of any size 2 to 4 core from LT Panels, excavating, taking out the required length of existing cable from loop, cutting the defective portion of cable old termination at end, providing new aluminium thimbles/lugs of suitable size and reconnecting the same with existing location and refilling of cable trench with existing sand and bricks. Note : The rate quoted shall deemed to inclusive of necessary earth work.
S&F weather proof cable junction box of size not less than 250 mm x 200 mm x 100 mm with terminals, IP 66 (minimum), suitable for outdoor installation & 10 to 25 Sqmm cable including 01 No 5/6 Amp MCB, 50 Amp rated 3 pole connector, fixing arrangement with MS flat of size 25 x 3 mm with necessary nuts, bolt and washers & including taking down existing un-serviceable junction box complete all as specified and directed.
M&L preparation of old painted surface of existing 9 m long steel poles with connected cross arms, cable protection pipes, clamps, street light brackets etc, and applying one coat of aluminium paint on complete height of the pole and applying one coat of synthetic enamel paint upto 0.80 m height from the top of coping with alternate coats of black and yellow paint strips 03 No Balck & 02 No yellow strips of 30 cm each, writing pole details & applying one coat of white wash on pole coping complete all as specified and directed.
Taking down defective street light / flood light / bollard light fittings of any make / type / capacity from top of pole / walls / high mast at a height upto 12.0 m, at any location, for repair work, re-fixing the same after repair work including testing and commissioning complete all as specified and directed. Note:- (i) M&L for Items like ballast, lamp, ignitor, capacitors, electronic drivers, surge protection devices etc shall be measured and paid separately under respective item of this schedule/BOQ. However rate quoted shall deemed to inclusive cost of required minor spares like nut bolts, circle clips, clamps etc. (ii) Necessary T&P like ladders/ manipulator etc required to take the fitting down shall be arranged by the contractor. (iii) M&L for repairs to LED Panel will be measured and paid seperately.
All as per serial Item No. 37.00 herein before but suitable for 45 to 100 W
All as per serial Item No. 37.00 herein beforee but suitable for 10 to 40 W
M&L in replacement for wiring from LED panel to driver for capacity 120-250 W LED fittings complete all as specified and directed.
All as per serial Item No. 40.00 herein before but for 45 to 100 W LED fittings
All as per serial Item No. 40.00 herein before but for 10 to 40 W LED fittings
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point including dismantling un-serviceable earthing complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
S&F in replacement of 12 KW, three phase, automatic Street Light time Switch consisting of Infrared Sensor based NATURE SWITCH for automatic switching ON / OFF Street Lights based on Lux level of natural light (required illuminance Level for Switching ON should be ≤ 30/60 Lux and for Switching OFF should be ≥ 10 Lux). The Sensor should also have part night operation facility of min 4 hrs to max 12 hrs or 4 hrs to 8 hrs. The sensor along with & including 3 Nos, suitable power contactors, 3 Nos incoming MCBs & 3 Nos outgoing MCBs of 32-40 Amps Each shall be enclosed in a pole / wall mountable Rust Proof, Electric Shock Proof, Termite proof and stain less steel Enclosure consisting of legs 0.6 m height with PCC (with/without HINGED LID) conforming to IP66 protection class 2 and circuit wiring shall be with min 10 sqmm copper conductor. The circuit should also have provision for Manual Operation (i.e., Sensor By-Pass option) complete all as specified and as directed.
S&F analog time switch 3 module suitable for street light timer panel / DG AMF Panel / Star Delta starter panel including taking down existing un-serviceable timer complete all as specified and directed.
S&F MCCB 4 pole 40 to 63 Amp 'C' series, breaking capacity 16 kA, Ics = 100% Icu, thermal magnetic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 ln) including necessary modification in the panel including taking down existing Un-serviceable MCCB complete all as specified and as directed.
M & L for disconnecting, removing 0.75HP to 2 HP motor 415 Volts 50 Hz 3 Phase from highmast gear box unit and carryout necessary rewinding of the burnt core with super enamelled copper wire of appropriate guage greasing of bearings, rotating shaft, replacing wom out nuts and bolts complete all as specified and as directed by Engr-in-Charge.
M & L for Repairs to High Mast/mid mast of upto 16 Mtr height lantern carriage/winch, checking for movement, inspecting the alignment, replacement of broken/defective SS wire rope complete, replacement flexible copper conductor, dismantling the lantern carriage from High mast of any height, check for any short circuit burnt wire, disconnecting and replacing the wires from light fittings, and driver unit, and re-fix the light fittings and re-align the carraige and light fittings as required complete, testing & commissioning complete all as specified and directed by Engineer-in-Charge. Note:- (i) SS Wire, flexible copper wire shall be mesured and paid seperatly. (ii) Cost of hiring of hydraulic crane suitable for working at up to 16 mtr height and T&P used for repair of high mast is deemed to be includad in unit rate.
Supply & replace stain less steel wire rope of size 6 mm dia with 7/19 construction after dismantling and dismantling the old damaged rope from position in High mast pole and connecting it with the motor winch and lantern carriage and doing the alignment and balancing of the carriage to hanging properly, complete all as specified and directed by Engr-in-Charge.
S&F Automatic battery charger of 12 V / 24 V , 0 - 10 / 0-5 A charging rate auto cut off system including taking down existing un-serviceable Automatic battery charger complete all as specified and directed.
S&F PVC insulated 3 core multistranded sheathed cable with 2.5 Sqmm copper conductor for connection from street light to terminal box drawn through street light pole or as indicated location including taking down existing un-serviceable cable complete all as specified and directed.
S&F MCCB 4 pole 100 Amp, breaking capacity 16 KA, 'C' series, Ics = 100% Icu, thermal magnetic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 ln) including necessary modification in the panel including taking down existing Un-serviceable MCCB complete all as specified and as directed.
S & F Display control panel (LED Board) for 62.5 to 625 KVA DG set of make as per existing including taking down existing un-serviceable Display control panel complete all as specified and directed by Engineer-in-Charge.
S & F Coolant temperature sensor (coolant control safety) for 62.5 to 625 KVA DG set of make as per existing including taking down existing un-serviceable Coolant temperature sensor complete all as specified and directed by Engineer-in-Charge.
S & F Fuel level indicator sensor for 62.5 to 625 KVA DG set of make as per existing including taking down existing un-serviceable Fuel level indicator sensor complete all as specified and directed by Engineer-in-Charge.
S & F AMF controller Assy for auto / manual operation for 62.5 to 625 KVA DG set of make as per existing including taking down existing un-serviceable AMF controller Assy complete all as specified and directed by Engineer-in-Charge.
S & F Control assy main generator panel for 62.5 to 625 KVA DG set of make as per existing including taking down existing un-serviceable Control assy main generator penel complete all as specified and directed by Engineer-in-Charge.
S & F Lube Oil pressure sensor adaptor (Oil control safety) for 62.5 to 625 KVA DG set of make as per existing including taking down existing un-serviceable Control assy main generator penel complete all as specified and directed by Engineer-in-Charge.
S & F Stop solenoid switch 12 Volts of make as per existing including taking down existing un-serviceable Stop solenoid switch complete all as specified and directed.
S & F Stop solenoid switch 24 Volts of make as per existing including taking down existing un-serviceable Stop solenoid switch complete all as specified and directed.
Supply & Fill Coolant for radiators of make as per existing complete all as specified and directed.
S & F Turbo charger for any capacity DG set of make as per existing including taking down existing un-serviceable Turbo charger complete all as specified and directed.
Supply & Fill Engine oil multi grade 15W40 including taking down un-serviceable Engine Oil complete all as specified and directed.
S & F Automatic Voltage Regulator fit for DG set of make as per existing including taking down existing un-serviceable Automatic Voltage Regulator complete all as specified and directed.
M & L for Calibration of FIP and fuel injector from the authorised dealer including petty replacements to make the FIP and injectors functional for the capacitiy of 62.5-625 KVA DG Set complete all as specified and directed.
M & L for Disconnecting the electric connection of Alternator of capacity 625 KVA DG set, taking the accumalator and cleaning the core assembly through air blower, heat varnishing with insulating material complete all as directed.
All as per Sl Item No. 66.00 herein before but for DG Set of 250 to 320 KVA
All as per Sl Item No. 66.00 herein before but for DG Set of 62.5 to 160 KVA
S & F Water Pump of make as per existing including taking down existing un-serviceable water pump complete all as specified and directed.
S & F Lube Oil pump high discharge of required standard size of make as per existing including taking down existing un-serviceable Lub Oil pump high discharge complete all as specified and directed.
S & F maintenance free battery of 12 V minimum 180 AH including terminal clamps, copper lead of suitable length including testing and commissioning including taking down existing un-serviceable battery complete all as specified and directed by Engr-in-Charge.
All as per Sl item No. 71.00 here in before but for 100 AH
M&L for Cleaning of external surface of DG set with cleaning agent for capacity 20 to 62.5 KVA of any make complete all as specified and as directed.
All as per Sl Item No. 73.00 herein before but for DG Set of 250 to 320 KVA
All as per Sl Item No. 73.00 herein before but for DG Set of 625 KVA
Cleaning of diesel tank of DG set of any capacity carefully by draining out fuel in the tank including disconnection from fuel system, De-scaling the diesel tank with water pressure and removing the complete sludge deposited, drying the tank, repairing any leakage, cleaning and testing of fuel line up to fuel pump inlet complete all as specified and as directed.
M & L for De-scaling of radiator of capacity 20 KVA to 62.5 KVA DG Set by dismantling the upper & lower tank and cleaning the core pipes with cleaning chemicals, components and arrest the leaking core by brazing dummy with lead including cleaning of upper and lower tanks and replacing the upper and lower gaskets and required nuts, bolts, refixing the same including testing complete all as specified and directed.
All as per Sl Item No. 77.00 herein before but for DG Set of 250 to 320 KVA
All as per Sl Item No. 77.00 herein before but for DG Set of 625 KVA
S & F Self starter 24 volt DC of make as per OEM including taking down existing un-serviceable Self starter complete all as specified and directed.
S & F Self starter 12 volt DC of make as per OEM including taking down existing un-serviceable Self starter complete all as specified and directed.
M&L for taking down, transporting, dismantling, repairing and servicing of self starter 12/24 volt DC at authorized service centre of OEM including assembling, bringing back, installing, commissioning and testing the same complete all as specified and as directed.
M & L for Maintanence and servicing the AMF panel and replace the unserviceable items and testing and replace unserviceable wiring connection in panel for automatic operation through relay, contactor, timer, sensor etc complete all as specified and directed.
S & F three pole power contactor type AC3 not less than 300 A with Aux contacts 2 Nos 2 NC, suitable for AMF panel includind taking down existing un-serviceable contractor complete all as specified and directed.
S & F AC Control contactor - M00AC - 15 4A at 415 V, suitable for AMF panel includind taking down existing un-serviceable contractor complete all as specified and directed.
S & F DC Control contactor - M00DC - 15 4A at 415 V, suitable for AMF panel includind taking down existing un-serviceable contractor complete all as specified and directed.
M & L complete servicing of 625 KVA DG Set as recommendations of manufacturer including replacement of air filter, fuel filter, engine oil filter, engine oil and servicing of lubrication system, fuel system, air intake system, electrical control system and safety check etc, complete all as per manufacturers instructional manual and all as specified and directed by Engineer-in-charge.
All as per Sl item No. 87.00 here in before but for 320 KVA DG set.
All as per Sl item No. 87.00 here in before but for 250 KVA DG set.
All as per Sl item No. 87.00 here in before but for 62.5 KVA DG set.
All as per Sl item No. 87.00 here in before but for 20 KVA DG set.
S & F Air cleaner / Bypass / Lub oil filter for 625 KVA DG set of make as per existing including taking down existing un-serviceable Air cleaner / Bupass / Lub oil filter complete all as specified and directed by Engineer-in-Charge.
All as per Sl item No. 92.00 here in before but for 320 KVA DG set.
All as per Sl item No. 92.00 here in before but for 250 KVA DG set.
All as per Sl item No. 92.00 here in before but for 62.5 KVA DG set.
All as per Sl item No. 92.00 here in before but for 20 KVA DG set.
S&F on-load change over switch 400 Amp capacity, 4 pole, 415 volts, manual change over with Sheet metal enclosure including taking down existing un-serviceable change over switch complete all as specified and directed.
All as per Sl Item No. 97.00 here in before but capacity of 200 Amp
All as per Sl Item No. 97.00 here in before but capacity of 100 Amp
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
8858Tender.pdf
Tender Documents • 0.79 MB
BOQ_861987.xls
BOQ • 0.76 MB
Download all tender documents and submit your bid