| 1 | L1₹14.2 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹15.0 L+₹22,533 (1.52%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹19.7 L+₹4.9 L (33.3%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
19 Jul 2021, 6:00 pmClosed
GE Chandigarh
GE Chandigarh
SPECIAL REPAIR/RENOVATION/REPLACEMENT OF OLD FLORESCENT TUBE LIGHT/CFL AND FIXTURE WITH ENERGY SAVING LED OF KV BUILDING AT K AREA UNDER GE CHANDIGARH.
2021_MES_439754_2
GE/CHD-13/2021-22
Open Tender
Civil Works
Item Rate
210 days
Chandigarh
Class E Cat b i
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹50,000
Yes
3 Aug 2021
26 Jun 2021
21 Jul 2021
26 Jun 2021
19 Jul 2021
7 Jul 2021
26 Jun 2021 - 2 Jul 2021
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed.
Taking down carefully old unsv copper/aluminium sub main wiring iny size any description and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed.
Taking down carefully old unsv MCD DBs ay type and description incl MCBs and depositing into MES store yard for ruse or issue under sch of credit complete
M&L Point wiring with 1.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable in and including concealed , non metalic rigid pvc medium grade ISI marked conduit not less than 19 mm with all fittings & other accessories and also including PVC insulated ISI marked unseathed FRLS cable of size 1.5 sq mm copper conductor as earth wire to common earth dolly including concealed in wall/ceiling, modular MS Box, 1.6mm thick with modular cover plate with frame as required at site suitable for modular switches, sockets, fan regulator etc for One light/fan point controlled by one way switch 6 amps 240 volts : Note:-1. Colour code of wiring should be (for phase -Red, Neutral-black & earth wire green) 2. Modular switch sockets fan regulators shall be meaured and paid separately udner respective items. 3. Cost of mudular MS box , modular cover plate an frame of any modules as required at site and as directed by Engineer-in-charge is deemed to be included in th quoted rates. (4) Making good on disturbed surfaces and quoted rate including M&L for white/colour wash (existing colour) to macth with existing surfaces, complete as directed by Engineer-in-Charge
All as per item No 4 above but one fan point controlled by one switch and one regulator.
All as per item No 4 above but one 3 pin 6 Amps switch socket out let point on independent board
All as per item No 4 above but one 3 pin 6 Amps switch socket out let point on same board
All as per item No 4 above but one call bell point controlled by one way bell push switch
All as per item No 4 above but one light point controlled by two way switch
All as per item ser no 4 herein before but wiring with 2.5 sqmm coppr conductor for power point
S&F ceiling rose surface bakelite 65x50mm three terminals complete all as specified ISI marked. (Make : Anchor/SSK/Cona)
S & F in repairs one way switch pino flesh type 230 Volt, single pole, 5 Amps, ISI marked, complete all as specified. (Make : Anchor/SSK/ Cona)
S & F Two way switch pino flesh typwe 230 Volt, single pole, 5 Amps, ISI marked, complete all as specified (Make : Anchor/SSK/Cona)
S & F socket 2 pin 5 Amps, 3 pin 5 Amps flush type, 230 volt single pole. (ISI marked), complete all as specified. ( Make : Anchor/SSK/ Cona)
S&F switch Pino flush type 15 Amps 230 volt, (ISI marked) complete all as specified. (Make - Anchor/SSK/ cona)
S & F multi socket 2 in 1, 3 pin 5 Amps and 3 pin 15 Amps 230 volt, (ISI marked), complete all as specified. ( Make : Anchor/SSK/ cona)
S & F fan regulator flush step type Any modle complete all as specified
S&F in repairs electric bell, AC 230V, single pole, complete all as specified. (Make : HAVELLS/LEGRAND/ABB)
S & F in repairs Bell Push flush type, 230 Volt, single pole, 5 Amps, (ISI marked), complete all as specified. (Make : HAVELLS/LEGRAND/ABB)
S & F LED tube light fitting box type made of CRCA sheet including 1x 18/20 watt retro LED tube rods with output lumen not less than 2100 and pre wired with high efficiency electronic driver with surge protection of 2 KV THD not less than 15%, CRI greater than 70%, PF greater than 0.9 and connecting with three core PVC copper flexible cable of size 23/0.0076 from ceiling rose to connector block complete all as specified. Make : Crompton/Halonix/Havells/Wipro/C&S/Philips/Bajaj/Osram.
S & F in repir LED Mirror light fitting complete made out of CRCA sheet including 1x10watt LED rod complete connecting up with three core pvc copper flexible cable of size 23/0.0076 from ceiling rose to connetor complete all as specified and as directed by Engr in charge Make :-Crompton/Halonix/Havells/Wipro/C&S/Philips/Bajaj/Osram.
S&F Surface mounted LED (1X4) Panel indirect light fitting 40Watts, 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed. MAKE :- Crompton/Halonix/Havells/Wipro/C&S/Philips/Bajaj/Osram.
Supply and Fixing lamp holder, angular type, PVC/ polycarbonate with back plate of capacity 5 Amps 230 volts suitabel for general lighting system complete all as specified and as directed. Make : Anchor//Leader/Bajaj
S&F LED lamp 9 watts complete all as spfd and directed. MAKE : Crompton/Halonix/Havells/Wipro/C&S/Philips/Bajaj/Osram.
S &F energy saving LED street light 45 watt luminaire with high power LEDs with lens of beam angle of 120 degree,luminaire made of pressure die cast aluminium body with built in heat sinks, painted with polyurethan/powder coated paint, enclosed with toughened glass including separate compartment for cable and incl sealed/compact driver for easy access during maintenance,suitable for operating on voltage 120 - 270 volt,AC,50 HZ,with Surge protection of 5 KV , out put Luminous efficacy not less then100 Lumen/Watt , CRI more then 70, conforming to IP 66, class 1 complete all as per Manufacturer's specifications including taking down old unserviceable fittings of any size/ wattage complete all as directed by Engr-in-Charge. Make : Crompton/Halonix/Havells/Wipro/C&S/Philips/Bajaj/Osram.
M&L for street light bracket made out of 32/40 mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 32x6 mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles/wall complete all as specified and as directed.
Supply and fixing Exhaust Fan AC single phase 230/240 volts of size 300mm sweep with louvre including provision of necessary walls opening and cementing work all as specified and directed Make : Havells/Bajaj/Usha/Orient
Supply and fix heavy duty wall mounted fan 450 mm sweep AC single phase 230/240 V with inbuilt regulator and facility. Make Havells and equivalent in Bajaj/Usha/Orient
Supply & fix and connecting up complete MCCB DB TPN 6 way (vertical), double door, 415V AC 50 Hz IP-43 protection conforming to IS-13032 universal mounting with copper bus bar, neutral link, earth link, earthing, studs, detachable gland plates with knowouts on both sides for housing of MCCB 125 Amps complete all as specified Make : Havells/ standard/indo asian
S&F factory made sheet metal enclosure for distribution board (Fixed to the wall), single pole and netural with 200 Amp rated bus bar, double door suitable for having MCB’s DB 8 Way, SPN, 240 Volt.complete all as specified of following capacities :-Make-ASCO/ABB/HAVELLS/INDO ASIAN
S&F factory made sheet metal enclosure for distribution board (Fixed to the wall), single pole and netural with 200 Amp rated bus bar, double door suitable for having MCB’s DB 4 way SPN, 240 Volt.complete all as specified of following capacities :-Make-ASCO/ABB/HAVELLS/INDO ASIAN
S & F in repars MCB, SPN, 240Volt, 40 Amps, breaking capacity 10 KA, Complete all as specified
S & F in repairs MCB, SP, 240Volt, 5 to 32 Amps, breaking capacity 10 KA, Complete all as specified
S & F in repairs MCB, Isolater 240Volt, 63 Amps, breaking capacity 10 KA, Complete all as specified
S&F in repairs blanking plates to cover unused space in DB’s. complete all as specified.
S&F in repairs sheet metal enclosures single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 240 volts, 20 Amps complete all as specified
Earth continuity conductor or main earthing lead fixed to wall on batten or tecess or chasess or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire.
S&F of sub main wiring with two single core 2.5 Sqmm and one single core 2.5 sqmm as earth continuity cable PVC insulated multi-straned copper conductor drawn through in and including PVC rigid no-metallic surface/concealed conduit of 25mm dia and connection at both ends with copper legs, colour code for phase Red /Yellow/Blur for neutral Black and for earth green, complete all as specified. MAKE : Finolex/ Havelle’s/Plaza/Poplycab
All as per Item No 38 here in above but of 4 Sqmm.
All as per Item No 38 here in above but of 6 Sqmm. Note for Sl No 38 to 40 Make of PVC cables : Finolex/Polycab/Havells Make of PVC Conduit : Mecury/Sudhaker/Avon Plast
M&L for earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI wire 4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20mm dia GI watering pipe ‘medium grade’, funnel with wire mesh, earthing chamber with cement concrete (1:2:4) type B-1, RCC chamber cover 80mm thick (1: 1 ½ : 3) type B1, excavation & earth work all as shown in electrical plate No 5 of SSR (Part-I) and testing on completion, complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32x6mm main earthing lead by means of galvanized bolts, nuts and washers with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point terminal block made out of phoshper bronzein sheet steel box, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 3.5/4 Core. MAKE - Havells/Polycab/Anchor/Finolex/KEI
All as per item No 43 above but cable of size 3.5 core 35 sqmm.
All as per item No 43 above but cable of size 3.5 core 50 sqmm.
All as per item No 43 above but cable of size 3.5 core 95 sqmm.
Supply and laying GI tubing light grade in tranches for protection of cable for 50 mm dia in cluding taking out. old pipe complete all as diercted by Engr -in-charge. Make :- JINDAL, TATA, SWATIK
M&L for trenches less cutting of road and culvert at the span of upto 4 mtr for crossing of UG cable and GI pipe of size up 50/80 mm dia
S&F Change over switch Off Load type changeover switch, 4 pole, 415 volts, 50 HZ AC, of capacity 100 Amps
Supply and fix in Electric water storage Heater (vertical type Geysers) 25 Ltrs 230 volts, AC single phase with and including grouting with high tensile rag bolt, nut & washer etc as directed as per site requirement .Geysers to have glass lines tank, fero glass coated container, PUF insulation, glass coated heating element, 8 BAR rated pressurer, thermostat cut off etc.including cutting holes and making good the disturbed surface complete all as specified and as directed by Engineer in charge. Make : Havells/Venus/Bajaj
M&L for cutting holes not exceeding 150 Sqcm into or through brick walls built in cement mortar or stone walls built in lime mortar / concrete including making good to the original surfaces of any description disturbed with and including painting with existing colour complete all as directed.
S&F GI pipes 15mm bore ISI marked medium grade with all fittings complete fixed on floor / wall with and including clamp including vent pipe etc complete all as specified and directed by Engineering-in-Charge. Make TATA / JINDAL/Prakash Tubes.
S&F PVC connection 450mm long for cold / hot water heavy duty made out of double layer at Nylon & wire fabric at pressure 6Kg / CM both side, CP brass 15mm bore coupling or nuts.
S&F angle stop valve 15mm bore heavy duty fancy type chromium plated with long shank and cup concealed in wall complete all as directed.
Bib taps, cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed of 15mm dia fancy type.
Renewing glazed tiles in patches area not exceeding 5 Sqm each including removing and cleaning old tiles preparing beds and laying or setting, jointing & pointing new or old tiles complete all as specified.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out . Note : Excavation shall be caried out manually. Exc with JCB will is not permitted.
Returning, filling in including spreading levelling, watering, and well ramming in layers not exc. 25 cm in soft/loose soil.
Removing excavated materials not exc 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point.
M & L for sand filling using approved clean dry sand for cushioning of under ground cables incl spreading levelling and well ramming in layers not exc 25 cm.
Supply and laying of class 'B' bricks for under ground cable protection as directed by Engineer- in - charge
M & L for Outdoor type Straight through ,jointing kit, heat shrinakable for 1.1KV grade UG cable with 3.5/4 core Aliminium conductor of size 25 to 50 Sqmm 3.5 Core complete along with jointing material all as specified and as directed. Make: M-Seal/ Denson /Birla-3M
M & L for Outdoor type heat shrinakable End jointing kit, for 1.1KV grade UG cable with 3.5/4 core Aliminium conductor of size 50 to 95 Sqmm 3.5 Core complete along with jointing material all as specified and as directed. Make: M-Seal/ Denson /Birla-3M
Supply and fixing sheet metal control board (Meter box) made of 1.6mm thick metal sheet and painting 2 coats with synthic enamel paint over a coat of primer including Aluminium bus bar and fixed with wall for fixing meter complete with wiring, fitting and accessories, locking arrangements with handle (minimum size of box 60 cmx75cm and adequate depth for the following equipments, internal wiring and termination of external cable, lugs and glands and conduits as required) comprising of following. Make of the Panel board confirming to CPRI specifications only. (a) Incoming 125 Amp 4 pole MCCB 25 KA - 01 Nos. (b) Bus bar 125 Amp Aluminium (c) supply & fixing for electronic type energy meters 3 Phase 4 wire 240 Volt 10 - 60 Amps 50HZ - 01Nos. MAKE: Indo asian/ M/S Power System and controls
SINGARI ELECTRICAL WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .