Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹21.1 L+₹2.4 L (12.9%)Rejected-Finance 45 PIR BABA TARUSHAW ROAD HALWARA AD LUDHIANA 141106 | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Other than lowest | |
| 3 | Rejected-Technical MANDIR ROAD NEW ABADI AKALGARH AIR FORCE STATION HALWARA TEH RAIKOT DISTT LUDHIANA PB 141106 | LUDHIANA | LUDHIANA | PUNJAB | 141106 | - | Rejected-Technical Not enlisted in c(i) Category | |
| 4 | Rejected-Technical GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | - | Rejected-Technical Not enlisted in c(i) Category |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
16 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Halwara
GE (AF) Halwara
REPAIR/MAINT OF WINDOW AND SPLIT TYPE AC IN TECHNICAL AND DOMESTIC AREA AT AF STN HALWARA
2024_MES_642632_1
GE/HAL-56/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY c(i)
8 documents required · 8 mandatory
₹500
GE (AF) Halwara
₹60,000
Yes
3 Apr 2024
16 Feb 2024
18 Mar 2024
16 Feb 2024
16 Mar 2024
2 Mar 2024
Amount
Taking down carefully window / Split AC unit of any size, any type, any capacity from the fitting/mountings, disconnecting power cables, drain pipes & accessories etc for repairs and refixing the AC unit and connecting up complete after carrying out necessary repairs to the entire satisfaction of the engineer in charge including transportation all as specified and directed. Note : spare parts will be measured and paid under relevent item of schedule.
M&L for servicing and cleaning of window / split type AC unit of any size, any capacity by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor/blower, by oiling, greasing, required welding/bracing, replacement of worn out rubber bushes of condensor motor, setting of grill alignment & knobs, checking for any leakages, provision of thermocoal for air tightness, testing etc all as specified and directed.
Removing the unserviceable blower motor double Shaft, suitable for window type AC 1.0/1.5/2.0 Ton unit and M&L for rewinding of blower motor, single phase, with super enamelled copper wire of existing gauge including replacement of gun metal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete.
Removing the unserviceable out door fan motor suitable for Split type AC 1.5/2.0/3.0 Ton out door unit and M&L for rewinding of out door motor, single phase, with super enamelled copper wire of existing gauge including replacement of gun metal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete.
Removing the unserviceable indoor motor suitable for Split type AC 1.5/2.0/3.0 Ton unit and M&L for rewinding of indoor door motor, single phase, with super enamelled copper wire of existing gauge including replacement of gun metal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete.
S&F in replacement blower motor double Shaft, suitable for window type AC 1.0/ 1.5/2.0 Ton single ended or double ended shaft as per existing one. Make : Blue Star/Voltas/LG/AUE/Marathon Electric or equivalent
S&F in replacement out door fan motor suitable for Split type AC 1.5/2.0/3.0 Ton out door unit single ended as per existing one. AUE/Marathon Electric or equivalent
S&F in replacement indoor motor suitable for Split type AC 1.5/2.0/3.0 Ton unit single ended as per existing one. AUE/Marathon Electric or equivalent
Removing the unserviceable reciprocating compressor from window/Split type AC and S&F new compressor suitable for 1.0 Ton window/split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/LG/ Carrier/Tecumesh/Videocon or equivalent
Removing the unserviceable rotary compressor from window/Split type AC and S&F new compressor suitable for 1.0 Ton window/split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/LG/ Carrier/Tecumesh/Videocon or equivalent
Removing the unserviceable reciprocating compressor from window/split type AC and S&F new compressor suitable for 1.5 Ton window/split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/LG/ Carrier/Tecumesh/Videocon or equivalent
Removing the unserviceable rotary compressor from window/split type AC and S&F new compressor suitable for 1.5 Ton window/split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/LG/ Carrier/Tecumesh/Videocon or equivalent
Removing the unserviceable reciprocating compressor from window/Split type AC and S&F new compressor suitable for 2.0 Ton window/ split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/LG/ Carrier/Tecumesh/ Videocon or equivalent
Removing the unserviceable rotary compressor from window/Split type AC and S&F new compressor suitable for 2.0 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/LG/ Carrier/Tecumesh/Videocon or equivalent
Removing the unserviceable reciprocating compressor from window/Split type AC and S&F new compressor suitable for 3.0 Ton split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/LG/ Carrier/Tecumesh/Videocon or equivalent
Shifting of Split type A/C , any type / any capacity, any make with necessary addition / alteration to window / wall complete all upto entire satisfaction and as specified and directed by Engr-in-Charge.
Dismantling of cooling(evaporator) coil for repairs of 1.5/2.0 Ton capacity window / split type AC made up of copper tubing and copper/aluminium cooling fins including brazing, welding etc replacement of copper/ aluminum tubing/fins as per site requirement, refixing in original position and testing etc complete all as specified and directed by Engr-in-Charge.
Dismantling of condenser coil for repairs of 1.5/2.0 Ton capacity window / split type AC made up of copper tubing and copper/aluminium cooling fins including brazing, welding etc replacement of copper/aluminum tubing/fins as per site requirement, refixing in original position and testing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of cooling coil for window type AC 1.5 Ton capacity including brazing, welding fixing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of cooling coil for window type AC 2.0 Ton capacity including brazing, welding fixing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of cooling coil for split type AC 1.5Ton capacity including brazing, welding fixing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of cooling coil for split type AC 2.0 Ton capacity including brazing, welding fixing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of condenser coil for window type AC 1.5 Ton capacity including brazing, welding fixing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of condenser coil for window type AC 2.0 Ton capacity including brazing, welding fixing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of condenser coil for split type AC 1.5 Ton capacity including brazing, welding fixing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of condenser coil for split type AC 2.0 Ton capacity including brazing, welding fixing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 20mm bore PVC drain pipe for split AC as per existing size complete all as specified and directed.
S&F in replacement of starting capacitor of 50+6 Mfd as per existing 50 Hz , AC suitable for 1.5/2 Ton A/C Make : TIBCON/SHARDA/EPCOS/ /KELTROL//BHEL/KEL or equivalent
S&F in replacement of starting capacitor of 45+6 Mfd as per existing 50 Hz , AC suitable for 1.5/2 Ton A/C Make : TIBCON/SHARDA/EPCOS/ /KELTROL//BHEL/KEL or equivalent
S&F in replacement of starting capacitor of 45+2 Mfd as per existing 50 Hz , AC suitable for 1.5/2 Ton A/C Make : TIBCON/SHARDA/EPCOS/ /KELTROL//BHEL/KEL or equivalent
S&F in replacement of starting capacitor of 36+6 Mfd as per existing 50 Hz , AC suitable for 1.5/2 Ton A/C Make : TIBCON/SHARDA/EPCOS/ /KELTROL//BHEL/KEL or equivalent
S&F in replacement of starting capacitor of 36 Mfd as per existing 50 Hz , AC suitable for 1.5/2 Ton A/C Make : TIBCON/SHARDA/EPCOS/ /KELTROL//BHEL/KEL or equivalent
S&F in replacement of starting capacitor of 80 to 120 Mfd as per existing 50 Hz , AC suitable for 1.5/2 Ton A/C Make : TIBCON/SHARDA/EPCOS/ /KELTROL//BHEL/KEL or equivalent
S&F in replacement running capacitor 36 to 60 Mfd 50Hz ,as per existing AC suitable for 1.5/2 Ton capacity AC Make :TIBCON/ SHARDA/EPCOS/ USHA/ or equivalent
S&F in replacement of capacitor 3 to 6 Mfd ,50Hz as per existing suitable for condenser motor of 1.5/2 Ton A/C capacity Make : SHARDA/EPCOS/ USHA/KELTROL/ or equivalent
S&F in replacement over load protector suitable for 1.5 /2 Ton A/C Make: Renutral / Shriram/Usha/Keltron or equivalent
S&F in replacement starting relay box type suitable for 1.5/2 Ton capacity AC Make : SRIRAM/RENUTRAL or equivalent
S&F in replacement of air cleaning filter , washable/cleanable type for window/split type A/C 1.5/2 Ton capacity all as specified and directed.
S&F in replacement of air filter pad of nylon cleanable/washable type of existing thickness for Split type A/C 1.5/2.0 ton Capacity as per existing sample all as specified and directed.
S&F in replacement of front grill of window type A/C of capacity 1.5 / 2 Ton as per existing one. Make : Blue star / Videocon / Amtrex / GEM or equivalent
S&F in replacement of thermostat suitable for 1.5 / 2 Ton capacity AC Make : Keltron/Renutral or equivalent
Material and Labour for replacement of blower Motor Blade suitable for Window Type AC 1.5/2 TR complete as per existing , and testing completeall as specified.
S&F in replacement Blower for indoor split AC As per existing complete all as specified.
Disconnecting of PCB for repair of window type AC 1.5/2.0 TR including refixing in original position and testing etc complete all as specified and directed by Engr-in-Charge.
Disconnecting of PCB for repair of split type AC 1.5/2.0 TR including refixing in original position and testing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PCB with remote for window type AC 1.5/2.0 TR complete all as specified. Make As per existing .
S&F in replacement of PCB with remote for split type AC 1.5/2.0 TR complete all as specified. Make As per existing .
S&F in replacement of indoor unit for split type AC 1.5 Ton capacity including brazing, welding fixing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of indoor unit for split type AC 2.0 Ton capacity including brazing, welding fixing etc complete all as specified and directed by Engr-in-Charge.
Material and labour for replacement of copper discharge tube of size 3/8" , duly nylon insulated complete all as specified.
Material and labour for replacement of copper suction tube of size 5/8" duly nylon insulated complete all as specified.
Material and labour for replacement of copper discharge tube of size 1/4" , duly nylon insulated complete all as specified.
Material and labour for replacement of copper discharge tube of size 1/2" , duly nylon insulated complete all as specified.
Supply & fixing Insulation material for any size of pipe complete all as specified.
Material and labour for replacement of blade (ISI Marked) of condensor fan motor (as per sample) for window type AC cap 1.5/2.0 Ton complete all as specified.
Material and labour for replacement of outdoor blade (ISI Marked) of condensor fan motor (as per sample) for split type AC cap 1.5/2.0 Ton complete all as specified.
Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging as prescribed by manufacturer, leak testing & commissioning of window type A/C Split type A/C of any type, any capacity, any make complete as directed by Engineer-in-Charge.
S&F in replacement of pencil type driers made in brass heavy duty suitable for window/split type Acs complete all as specified.
S&F in replacement of pin Valve /gas charging Valvesuitable for window/split type Acs complete all as specified.
Supply & fixing single pole & neutral enclosure with two pin and earth plug and socket including MCB SP 32 Amp complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 4 KVA wall mounting type electronic voltage stabilizer for automatic operation, single phase naturally air cooled indoor type complete all as specified.
S&F in replacement 5 KVA wall mounting type electronic voltage stabilizer for automatic operation, single phase naturally air cooled indoor type complete all as specified.
S&F MCB DP 32 Amps, 240 volts complete all as specified.
Copper caplary tube any size suitable for window/split AC in replacement complete all as specified.
S&F in replacement Blower for window AC 1.5/2.0 TR as per existing size complete all as specified.
S&F in repairs Brass Nuts (1/4" Dead Nuts )
S&F in repairs Flair Brass Nuts (1/2" Nuts )
S&F in repairs Flair Brass Nuts (3/8" Nuts )
S&F in repairs Flair Brass Nuts (5/8" Nuts )
S&F in repairs Butane Cartage 414 ml Gas for Brazing/welding AC
S&F in repairs Bakalight Connecter ( for ACThree Conection )
S&F in repairs Brass Thimble for AC compressure (100 Pec )
S&F in repairs Copper Brazining Rod
S&F in repairs theade taps complete all as specified.
S&F in repairs self adhesive taps (Brown/Black Cello Tape) size 50mm X 30 mtr complete all as specified.
S&F in repairs PVC insulation tap 25 mm X 25 mtr complete all as specified.
Supply and filling refrigerant mafron Gas M-22 complete all as specified.
Supply and filling refrigerant gas 134a complete all as specified.
Supply and filling refrigerant gas R-32 complete all as specified.
Supply and replace high and low voltage relay 230V, 50 Hz suitable for single phase voltage stabilizer of capacity upto 5 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and replace power circuit board 230V, 50 Hz suitable for single phase voltage stabilizer of capacity upto 5 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and replace voltmeter 0-300V suitable for single phase voltage stabilizer of capacity upto 5 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and replace Switch piano, flush type single pole, one way 16 Amps suitable for single phase voltage stabilizer of capacity upto 5 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and replace internal transformer suitable for single phase voltage stabilizer of capacity upto 5 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and replace indicator lamps of required colour suitable for single phase voltage stabilizer of capacity upto 5 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and replace 3 way terminal connector suitable for single phase voltage stabilizer of capacity upto 5 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and replace PVC Insulated and PVC Round Sheathed three Core, 6 sqmm Copper Conductor Heavy Duty Cables for Voltage Grade upto 1100 Volts
Supply and replace PVC Insulated and PVC Round Sheathed three Core, 4.0 sqmm Copper Conductor Heavy Duty Cables for Voltage Grade upto 1100 Volts
Supply and replace PVC Insulated and PVC Round Sheathed three Core, 2.5 sqmm Copper Conductor Heavy Duty Cables for Voltage Grade upto 1100 Volts
Disconnecting of PCB for repair of inverter type split AC 1.5/2.0 TR including refixing in original position and testing etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PCB with remot for inverter type split AC 1.5/2.0 TR complete all as specified. Make As per existing .
S&F in replacement Out door fan motor suitable for inverter type Split AC 1.5/2.0 Ton out door unit single ended as per existing one.
S&F in replacement indoor motor suitable for inverter type Split AC 1.5/2.0 Ton unit single ended as per existing one.
CHOUDHARY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .