| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.0 LAccepted-AOC D NO 5 13 24 1 BEHIND SAHUWALA CYLINDERS IDA AUTONAGAR VISAKHAPATNAM 530 012 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | L1 | Accepted-AOC Lowest Bid Accepted | |
| 2 | L2₹71.0 L+₹4.0 L (5.91%)Rejected-Finance 45 58 5 15A AKSHAYA NARASIMHANAGAR VISAKHAPATNAM 530 024 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530024 | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | Rejected-Technical 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | - | Rejected-Technical Being MoU not submitted from the original manufacturer of existing lifts |
Tender Value
₹69.9 L
EMD Value
₹1.3 L
Closing Date
14 Apr 2025, 6:00 pmClosed
Col Akhil Mehrotra, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
COMPREHENSIVE MAINTENANCE AND REPAIRS REPLACEMENT OF DEFECTIVE PARTS OF LIFTS OF ECE, IES, OTIS AND JOHNSON MAKE AT NAVAL PARK, NAUSENA BAUGH, INS DEGA, ND V KUTHAR BLOCK INS SATAVAHANA UNDER GE UTILITYI, VISAKHAPATNAM
2025_MES_692215_2
82512/E8
Open Tender
Civil Works
Item Rate
330 days
Visakhapatnam
As per NIT documents
9 documents required · 9 mandatory
₹1,000
GE Utility I
₹1.3 L
Yes
27 Jun 2025
24 Mar 2025
16 Apr 2025
24 Mar 2025
14 Apr 2025
31 Mar 2025
Amount
Notes for Serial Item No. 1: [a] MANPOWER TO BE EMPLOYED: The contractor shall employ 3 Nos lift mechanics and 3 Nos Helper with sound knowledge and adequate experience in lift repair / maintenance, available Round the Clock. All the manpower employed shall report to Office of AGE [E/M]/ Complaint Cell for day to day maintenance and efficient operation of Lifts. [b] The rate quoted by the tenderer shall deemed to inclusive for all other spares like Push buttons, Door rollers, guide shoes, Brake coils, limit switches, door couplers, alarms, Position indicators (LOP), contactors, LED lights, Relays, Cabin fans, Lubrication oil, control fuses, Greases and buffing of landing, car panel and door wherever is required as directed by Engineer-in-charge etc which have not been catered for separately. No extra cost is admissible on this account and supply and fixing of all Major and Minor Spares viz. Mechanical / Electrical / Electronic / LED Lights etc. (except Spares catered vide Serial Item No. 2 to 29 of BoQ ) as and when required for trouble free, smooth and efficient functioning of lifts including overhauling as and when required to all mechanical parts of lifts, Rewinding of Electric Motors, repair/maintenance of Gear Unit, repair / maintenance of Door Drive, Controllers, Pulleys, Limit Switches, Relays etc. complete all as directed by the Engineer-in-Charge.
[c] All the safety measures including ARDs shall be ensured for serviceable condition round the clock and nothing extra shall be paid on these accounts. [d] Spares catered vide Serial Item No. 2 to 29 of BoQ shall be measured and paid separately as "Supply Only" whenever required and rate quoted for Serial Item No. 1 of BoQ shall be excluding the same. However, fixing / repairs shall be deemed to be included in the rate quoted. [e] The rate quoted shall be deemed to be inclusive of testing of each lift by Licensed Lift Inspector of Government of Andhra Pradesh twice in Contract Period for worthiness of the Lift in respect of safety. Certificate issued by the Licensed Lift Inspector shall be submitted to the Engineer-in-Charge and a copy of Certificate shall be displayed in all Lift Cabins as directed by Engineer-in-Charge. [f] Emergency Light and necessary tools shall be available in a tool box in the shift for smooth functioning of lifts. [g] Conveyance and communication system like mobile phone etc. shall be provided by the contractor to all Lift Mechanics and Helpers. [h] The contractor shall abide by the latest Labour Rules and Minimum Wages Act. [i] Wages paid by the contractor to the persons employed shall not be less than the minimum wages fixed by State / Central Government from time to time whichever is higher.
[j] The contractor is responsible for making subscription towards Insurance, EPF, ESI, Labour Welfare Cess etc., as applicable and shall pay Gratuity, Bonus etc to the Workmen as per existing Labour Rules / Acts / Regulations and rate quoted shall be deemed to be included for the same. [k] DRESS CODE: The contractor shall provide the workmen with Dark Blue Colour Uniform [Formal Pant & T-Shirt] with labels showing / printed i.e. "Name of the Firm and Designation" on Front and "GE [U - I] [V] & GE [U-II] [V]" on the back of the T-Shirt along with protective clothing / gear. The contractor shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. [l] The contractor shall be responsible for all Accidents / Injuries happening to the workmen. Any accident causing Minor / Fatal Injury, Partial Disability due to any untoward incident or non-adherence to Safety and IE Regulations or fault in maintaining of Lifts System / Safety Mechanism or on account of any mishandling / wrong operation / lack of knowledge of safety precautions or on account of any circumstances beyond his/their control, the contractor shall be solely responsible for settling all claims of compensation to the deceased, failing which department will have a right to recover any sum indicated / claimed by Labour Commissioner / Court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Contractor shall provide first aid boxes to meet any emergency situations. [m] The contractor shall carryout the comprehensive maintenance of the lifts catered under subject work through the Original Equipment Manufacturer of that lift or from their accredited / authorised agencies only. The lowest bidder shall submit MoU from the Original Equipment Manufacturer of the Lift or from their accredited / authorised agencies to provide technical support, trained persons for maintenance & testing and spares before commencement of the work to GE. The spares shall be of the make as per existing or as per the OEM.
Supply only Main Contactor with Coil, 60 Amps , Power Contactor with 2 NO + 2NC Auxiliary Contacts and with 230 Volts, DC Coil complete all as specified and as directed.
Supply only Power Contactor, 32 Amps with 02 No + 2 NC Auxiliary Contacts with 230 Volts AC / 110 Volts DC complete all as specified and as directed.
Supply only Trailing Cable 10 Core X 0.75 Sq.mm complete all as specified and as directed.
Supply only Microprocessor L 40 BWA complete all as specified and as directed.
Supply only Input Module 24 Volts DC I/P or Potential Free Relay O/P Contact to match with Micrologix 1200 complete all as specified and as directed.
Supply only Full Length Infrared Sensor 64 Beams for Car Door including Transmitter, Receiver and Control Unit working on 230 Volts, AC complete all as specified and as directed.
Supply only the automatic rescue device to passenger lift of capacity 680 kg. Make:-ECE/IES/AS PER OEM.
Supply only the automatic rescue device to Goods lift of capacity 2000 kg. Make:-ECE/IES/AS PER OEM.
Supply only Converter Card of Automatic Rescue Device to Convert 72 Volts DC Input to 24 Volts DC Output for Control Circuit Goods lift of capacity 2000 Kg complete all as specified and as directed.
Supply only Mosfet Card of Automatic Rescue Device to covert 72 Volts DC to 230 Volts AC 3 Amps Rating complete all as specified and as directed.
Supply only Rotary Encoder for Speed feedback of Main Drive complete all as specified and as directed.
Supply only Door Motor with Built-in Rotary Encoder and suitable VVVF Drive for Car Door operation complete all as specified and as directed.
Supply only VVVF Drive 11 KW to 15 KW for Lift Motor of 9 KW to 11 KW including feeding all parameters and interfacing with Controller Micro Processor and Drive including setting of basic parameters to obtain the desired and designed value of various motions of the lift complete all as per manufacturer's instructions, complete all as specified and as directed. [a] Input Voltage: 380 to 460 Volts [b] Phase: 3 Phase [c] Motor Power in KW: 11 KW [d] Capacity in KVA: 55.04 KVA
Supply only in repairs/rewinding gear motor complete assembly suitable for 10 passenger lift with 1.5 Mps serving G+14 floor with a travel of 30 m along with traction sheave and testing complete all as specified and as directed.
Supply only Gear motor with base suitable for upto 10/13 Passenger lift with 1.5 Mps serving G+14 floor with a travel of 30 m along with traction sheave and testing complete all as specified and as directed.
Supply only LOP made out of AISI 304 Grade Stainless Steel Sheet of minimum 1.5 mm thick [Scrolling Type] including Buttons,G+14 Lock, all other relevant features and wiring complete all as specified and as directed.
Supply only COP made out of AISI 304 Grade Stainless Steel Sheet of minimum 1.5 mm thick [Scrolling Type] including Buttons,G+14 Lock, all other relevant features and wiring complete all as specified and as directed.
Supply only over speed governer pully assembly with rope suitable for 10/13 passenger lifts with 1.5 Mps serving upto G+14 with a travel of upto 45 meters for mechanical safety complete all as specified and as directed.
Supply only over speed governer pully with rope suitable for 2000 Kg goods lifts with 0.5 Mps serving upto G+14 with a travel of upto 45 meters for mechanical safety complete all as specified and as directed.
Supply only Stainless steel false ceiling suitable for 8/ 10 Passenger lift, made out of 0.8mm thick AISI 304 Grade Stainless steel sheets including provision of 4 Nos. of 8 Watt LED downlights and 01 No. of fan grill complete all as specified and as directed.
Supply only Main motor sheave four groves and 540 mm dia, speed 1.5m/s for passenger lifts complete all as specified and as directed.
Supply only Main motor sheave four groves and 640 mm dia, speed 0.5m/s for goods lifts complete all as specified and as directed.
Supply only Defelector Pulley five groves and 540 mm dia for passenger lifts complete all as specified and as directed.
Supply only Main Hoist Steel Rope of size 10/13 mm, Heavy Duty complete all as specified and as directed.
Supply only Charger Card of Automatic Rescue Device 230 Volts Input/72 Volts Output complete all as specified and as directed.
Supply only Main Controller Transformer Primary 415 Volts, AC, 50 Hz, Secondary - 24 / 110 / 130 / 230 / 270 Volts, AC, 500 Volts complete all as specified and as directed.
Supply only Floor Relay Oscillator Switch Optical type working on 12/24 Volts, DC complete all as specified and as directed.
Supply only PVC floor mat of 1.5mm thick suitable for both passenger & goods lift of any capacity complete all as specified and as directed.
Notes for Serial Item No. 01 to 29 of BoQ: [a] The work shall be carried out in the Lifts installed at Naval Park, Nausena Baugh, INS Dega, ND (V) (Kuthar Block) INS Satavahana Under GE [Utility-I], Visakhapatnam [b] Make of the Lifts :ECE/ IES/OTIS/JOHNSON [c] The contractor shall carryout the repair works under this contract through the Original concerned Equipment Manufacturer of the respective lifts . The contractor shall submit MoU from the Original Equipment Manufacturer of the Lifts to provide technical support, trained persons for carrying out repairs/ replacement & testing of lift components/ accessories/ controllers alongwith technical bid. The spares shall be of the make as per existing or as per OEM recommendations.
Velox Engineering Solutions Pvt Ltd (BID ID -3280801)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .