Loading…
Loading…
Tender Value
₹1.8 Cr
EMD Value
₹2.4 L
Closing Date
9 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
30 days
Expenditure
Capital (Works)
WORKS
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway.
Note for Technical Eligibility Criteria: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
"Any signal interlocking works involving El OR RRI OR PI OR IBS OR LC gate Interlocking OR UFSBI OR Track circuit AFTC OR (SSDAC OR MSDAC OR HA-SSDAC) OR Automatic signaling. (PCSTE/SR letter No. 167570/SG.191/Similar nature of work dated 19.09.2023 Sl No.3)". while 1.1.1 bidding, the bidder should submit an undertaking that they will procure item from RDSO Approved firm. The successful bidder shall submit an MOU with RDSO approved EI OEM. MoU shall include after sales Support required during warranty period and beyond the Warranty period upto the codal life of the item, training to railway officials, AMC OR ARC etc.
27 conditions · 3 needing a document upload
All the tenderers/Contractors have to deposit full Bid Security and tender document cost as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards . All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded failing which offer will be summarily rejected.
Until a formal agreement is prepared and executed, acceptance of this tender shall constitute a binding contract between us subject to modifications, as may be mutually agreed to between us and indicated in the letter of acceptance of my/our offer for this work.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract for works 2022, with all correction slips up-to-date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We offer to do the work for DRM/S&T/TVC, at the rates quoted in the attached schedule and hereby bind myself/ourselves to complete the work in all respects within the period of completion stipulated in the tender document, from the date of issue of letter of acceptance of the tender. The amount as stipulated in the tender document is herewith forwarded as Bid Security. Full value of the bid security shall stand forfeited without prejudice to any other right or remedies in case my/our Tender is accepted and if : (a) I/We do not execute the contract documents as stipulated in performance guarantee clause of GCC for works 2022 as detailed in general instructions. (b) I/We do not commence the work within seven days after receipt of orders to that effect.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
Manual submission of Bid Security and cost of tender form cannot be entertained/Considered and hence no need of uploading the scanned copy of financial instruments
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
INSTRUCTIONS TO TENDERERS
The tenderer shall thoroughly go through the entire tender documents and strictly adhere the instructions and directions given at different pages.
Tender Document Cost for this work is Nil.
Unreleased Bid Security, if any, held with the Railway Administration, shall not be adjusted towards the Bid security to be remitted.
If the Tenderer(s) deliberately give(s) wrong information/ incorrect documents in his/their tender or create circumstances for the acceptance of his/their tender, the Railway reserves the right to reject such tender at any stage. The entire Bid Security and any other dues available with Railway against that contract will be forfeited. Action will be taken to suspend the business with the tenderer for a period of two years. In addition, Administration reserves the right to prosecute under suitable law.
All terms and conditions in the tender documents are binding on the Tenderers.
Railways reserves the right to accept or reject any or all the tenders and to award the work in whole or in part without assigning the reason for any such action.
The Tenderers are advised to visit the site of work in their own interest and acquaint themselves with the site conditions and expected quantum of work and assess all the site specific difficulties to be experienced while executing the same and the rate shall be arrived duly considering all the facts above and quoted in the tender. Any representation at a later date specifying the site difficulties shall not be considered.
The bidder has to fill in his quoted rate against each item in the Bid rate / Unit rate column. If the bidding unit is Above/ Below/ Par, the bidder can select the %Above, %Below or %At Par option from the drop down list in the same column. If the bidding rate is Rs. or Rs./ unit, the bidder has to quote his rate for the item group or individual item accordingly
All the bidders/tenders should ensure that they are GST compliant and their quoted tax structure/rates are as per GST Law
In case of any wrong information submitted by tenderer, the contract shall be terminated, Bid security, Performance Guarantee(PG) and Security Deposit(SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 2(Two) years
Signalling arrangements for the Proposed Relocation SPART Siding and Extension of PF No.2. at Ernakulam Junction station
TVC-SNT-SIG-25-26-32
TVC-SNT-SIG-25-26-32
Open
Works - General
6 Months
Thiruvananthapuram, Kerala
₹0
₹2.4 L
9 Mar 2026
12 Feb 2026
93 items across 3 schedules · ₹81,58,231.28 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as- made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above" | Sheet | 120.00 | 382.12 | 45,854.4 |
| 2 | Supply and Provision of indicative type Class D S u r g e Protection Device f o r 2 4 V DC/48V DC (spark g a p type), w ith Potential Free contacts and installed as per the instructions of the Engineer i n c h a r g e a t s i t e ( OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make).All o t h e r miscellaneous m a t e r ia ls required for installation shall be supplied by the contractor. | Numbers | 2.00 | 6,328.8 | 12,657.6 |
| 3 | Supply and Provision of indicative type Class D SPD of Operating Voltage of 110V AC/DC with Potential Free contacts and installed as per the instructions o f t h e Engineer in charge a t site (OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make). All other miscellaneous materials required for installation shall be supplied by the contractor. | Numbers | 2.00 | 6,830.72 | 13,661.44 |
| 4 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 10.00 | 1,707.55 | 17,075.5 |
| 5 | Supply o f L o w maintenance secondary cells of t h e f o l l o w i n g c a p a c i t i e s w i t h necessary i n s p e c t i o n a s p e r specificatio n/ drawing/ description enclosed in this document.b)Supply of Secondary cells - 2V-80AH capacity | Numbers | 10.00 | 3,379.2 | 33,792 |
| 6 | Supply of track feed battery charger IRS:S 89- 2013 | Numbers | 2.00 | 4,375.25 | 8,750.5 |
| 7 | Supply of 'B type choke IRS:S 65-83 | Numbers | 4.00 | 2,855.6 | 11,422.4 |
| 8 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site.) as per drawing enclosed | Numbers | 85.00 | 262.65 | 22,325.25 |
| 9 | Preparation of Cement concrete for covering of G I Pipes/cables. Providing & Laying in position c e m e n t c o n c r e t e o f specified proportion i n c l u d i n g c o s t o f cement, centering and shuttering with 1:3:6 composition 1 Cement: 3 Sand: 6 grade stone aggregate 25mm nominal size) (Cement, M-Sand, stone jelly of 25mm and a l l other misc materials required f o r the work should be supplied by Contractor). | cum | 20.00 | 9,361.46 | 1,87,229.2 |
| 10 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 1700.00 | 64.1 | 1,08,970 |
| 11 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0 . 6 m t o accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. (Laying of cables is not included in this schedule). | Metre | 99.00 | 314.41 | 31,126.59 |
| 12 | Excavation of trench along route of existing cable duct, opening t h e slabs to accommodate additional cable laying, REPOSITIONING the slabs removed after the cables are laid and PLASTERING with cement mortar, and refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives a t site. (Laying of cables i s not included i n this schedule.)[Cement,M Sand and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Metre | 160.00 | 161.92 | 25,907.2 |
| 13 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by r a m m i n g a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / R C C p i p e s . During excavation o f trench, i t has t o b e ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall b e from t h e b o t t o m o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 306.00 | 385.45 | 1,17,947.7 |
| 14 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 12.00 | 501.03 | 6,012.36 |
| 15 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 168.00 | 208.54 | 35,034.72 |
| 16 | Provision o f G I pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall b e closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out a s per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule). [Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required f o r t h e work shall be supplied by the Contractor]. | Metre | 380.00 | 182.87 | 69,490.6 |
| 17 | Laying o f signaling/power/ telecommunication cables a s p e r c a b l e plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s n o t included i n this schedule). | Metre | 9500.00 | 18.18 | 1,72,710 |
| 18 | Placing of one row of country bricks of size approximately 2 2 0 m m x 1 0 0 m m x 60mm breadth wise horizontally above the cables in 0.3m width trench.[Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor]. | Metre | 1700.00 | 62.99 | 1,07,083 |
| 19 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling." | Metre | 1700.00 | 15.4 | 26,180 |
| 20 | "Digging of pit to a depth of 800mm of size 300mmX300mm, casting of concrete foundation o f size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. T h e cable markers s h a l l b e provided a t an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions a n d also a t every track/road crossing." | Numbers | 85.00 | 123.35 | 10,484.75 |
| 21 | Excavation o f c a b l e c o i l p i t t o a s i z e of 1.5mx1.5m and depth a s instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling t h e underground cables and placing closely one layer o f country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks o f size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 8.00 | 949.05 | 7,592.4 |
| 22 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 10.00 | 8,850 | 88,500 |
| 23 | Supply of Main LED Signal Aspect - Red as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 10.00 | 9,233.5 | 92,335 |
| 24 | Supply of subsidiary Signal Aspect - Calling on LED a s per RDSO Specifications SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 5.00 | 5,726.13 | 28,630.65 |
| 25 | Supply o f subsidiary Signal Aspect - Shunt LED a s p e r R DSO Specification SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 75.00 | 5,740.7 | 4,30,552.5 |
| 26 | Supply of LED based stencil type route indicator ( 2 Wa y ) w h i t e L E D ( W i t h Housing) as per technical specification | Numbers | 4.00 | 67,260 | 2,69,040 |
| 27 | Manufacture a n d supply o f Enameled Number plates as per drawing No.TY/08/2008 with fixing arrangements and fixing them o n t h e existing S i g n a l s a s per the instructions of Railway representative at site.[Enameled number plates w i t h fixing arrangements w i t h bolts a n d nuts shall be supplied by the Contractor]. | Numbers | 24.00 | 305.25 | 7,326 |
| 28 | Supply o f Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply o f colour light Signal pole 3.6m tall and 140 mm dia (Galvanised) | Numbers | 6.00 | 4,737.7 | 28,426.2 |
| 29 | Supply o f surface base t o suit C L S Signal pole 140mm d i a w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 6.00 | 6,814.5 | 40,887 |
| 30 | Supply of ladder with platform and shoes to suit C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary i n s p e c t i o n a s p e r specification/ drawing/ description enclosed in this document. b)Supply o f l a d d e r w i t h p l a t f o r m ( 3 . 6 m ) for CLS(Galvanised) | Numbers | 6.00 | 5,494.5 | 32,967 |
| 31 | Supply of post type shunt signal - complete with hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 6.00 | 5,087.5 | 30,525 |
| 32 | Supply o f Ground type shunt signal - complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 2.00 | 7,463.5 | 14,927 |
| 33 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting s o c k e t , w i t h n e c e s s a r y inspectio n a s per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) | Numbers | 7.00 | 14,278 | 99,946 |
| 34 | Supply of Calling On Signal / 'A' marker light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Calling On Signal | Numbers | 6.00 | 3,663 | 21,978 |
| 35 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small | Numbers | 14.00 | 2,645.5 | 37,037 |
| 36 | Supply of C-marker/A-marker Name Plate | Numbers | 7.00 | 253.91 | 1,777.37 |
| 37 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, f o r fi x i n g resistors and condensers, M S flats 2 5 m m x 6 m m brass bolts a n d n u t s , paints, soldering materials, resistors, condensers and all other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 5.00 | 4,945.51 | 24,727.55 |
| 38 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, f o r fi x i n g resistors and condensers, M S flats 2 5 m m x 6 m m brass bolts a n d n u t s , paints, soldering materials, resistors, condensers and all other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Wiring of Signal/ Point/ LC control circuit (up to 8 relays/plug in type) | Set | 1.00 | 8,786.26 | 8,786.26 |
| 39 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, f o r fi x i n g resistors and condensers, M S flats 2 5 m m x 6 m m brass bolts a n d n u t s , paints, soldering materials, resistors, condensers and all other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ LC control circuit (up to 12 relays/plug in type) | Set | 1.00 | 11,355.02 | 11,355.02 |
| 40 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, f o r fi x i n g resistors and condensers, M S flats 2 5 m m x 6 m m brass bolts a n d n u t s , paints, soldering materials, resistors, condensers and all other miscellaneous materials required f o r the work shall be supplied by the contractor]. d)Wiring of Signal/ Point/ LC control circuit (up to 20 relays/Plug in type) | Set | 1.00 | 13,597.41 | 13,597.41 |
| 41 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using t e a k w o o d c a b l e c l a m p s a n d base planks, termination of cables, provision of ND type fuses o f required capacities, provision o f copper bus b a r f o r supply terminals, wiring, provision of termination particulars diagra m b o a r d using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic sheet of thickness 3mm wherever required. The termination a n d cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f P B T terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, b r a s s bolts and n u t s and washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 5 0 m m x 50mm for c a b l e c l a m p s , 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic s h e e t 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 120.00 | 167.99 | 20,158.8 |
| 42 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using t e a k w o o d c a b l e c l a m p s a n d base planks, termination of cables, provision of ND type fuses o f required capacities, provision o f copper bus b a r f o r supply terminals, wiring, provision of termination particulars diagra m b o a r d using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic sheet of thickness 3mm wherever required. The termination a n d cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f P B T terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, b r a s s bolts and n u t s and washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 5 0 m m x 50mm for c a b l e c l a m p s , 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic s h e e t 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. b)Termination u s i n g P B T f u s e b l o c k i n cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 15.00 | 201.27 | 3,019.05 |
| 43 | Fixing o f plug boards, 5 0 w a y terminal blocks with 2BA terminals, and wiring of relays a s per t h e approved circuit diagram using w i r e PVC 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall b e provided horizontally a n d vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o provide smooth materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes wiring o f contacts f o r data l o g g e r a n d terminating t h e m i n t a g blocks, provision of relay index board.(Supply o f relays, plug boards, connectors and retaining clips is not covered i n this schedule). [Wire P V C 16/0.2mm copper, t a g blocks, 2BA terminals, h a r d wood p l a n k o f size 600mmx 900mmx25mm with decolum finish, M S angles o f size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors a n d condensers, phynolic sheet 6mm thick of size 1200mmX1800mm with aluminium grooved channel f r a m e f o r relay index board, paints, s o ld e r in g materials, bunching t h r e a d , wire wound resistance, condenser, w i r e supporting tray with cover of suitable size made of PVC, paint, varnish and a l l o t h e r miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Relay | 24.00 | 1,045.76 | 25,098.24 |
| 44 | Fi x i n g o f additional p l u g b o a r d s , 5 0 ways terminal blocks and wiring of additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall b e provided w h e r e v e r required. Alterations t o Relay particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , p l u g boards, connectors and retaining c l i p s a n d 5 0 way terminal boards is not covered in this schedule). [Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing resistors a n d condensers, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made o f PVC, paint, v a r n i s h a n d a l l other miscellaneousmaterials required f o r t h e work shall be supplied by the Contractor ] | Per Relay | 85.00 | 726.5 | 61,752.5 |
| 45 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. T h e w o r k includes painting alterations a n d releasing the unwanted wires carefully without disturbing the existing wiring. [ W i r e P V C 1 6 / 0 . 2 m m c o p p e r , soldering m a t e r i a l s , b u n c h i n g t h r e a d s , condensers, resistances and teakwood plank for fixing them a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Relay | 162.00 | 695.67 | 1,12,698.54 |
| 46 | Supply of Handheld True RMS Multi Meter, as per Technical specification | Numbers | 4.00 | 23,192.34 | 92,769.36 |
| 47 | S u p p l y o f D o u b l e w a l l e d corrugated p i p e - 1 0 3 . 5 m m i n n e r d i a & 1 2 0 m m o u t e r dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6 m o f pipe as per Technical specification | Metre | 318.00 | 365.19 | 1,16,130.42 |
| 48 | Supply of GI pipes - 50mm dia -3.65mm thick as per Technical specification | Metre | 12.00 | 457.88 | 5,494.56 |
| 49 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 536.00 | 1,119.16 | 5,99,869.76 |
| 50 | Supply and laying o f P V C Warning Tape colour Orange, width o f 250mm (10") by printing with black letters 'Indian RailwaySignal/Telecom/OFC Cable' on both sides | Metre | 800.00 | 46.15 | 36,920 |
| 51 | Supply of Track Feed Resistance | Numbers | 5.00 | 287.77 | 1,438.85 |
| 52 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 1050.00 | 61.44 | 64,512 |
| 53 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 250.00 | 93.02 | 23,255 |
| 54 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 60.00 | 103.84 | 6,230.4 |
| 55 | Supply of ND Fuse of various capacities (Per unit=Per fuse) | Per Unit | 60.00 | 37.74 | 2,264.4 |
| 56 | Excavation o f pit, erection o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawl of jumper wires f o r Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with o n e coat of red- oxide and two coats of aluminium paints. | Numbers | 1.00 | 5,029.69 | 5,029.69 |
| 57 | Installation of combined type point machine-IRS t y p e a n d connecting a l l ground connections including wiring and termination in point machine a n d interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm c o p p e r w i r e and p a i n t i n g . This work i n c l u d e s p r o v i s i o n of insulation to stretcher bars, throw b a r l u g and "D" bracket w h e r e v e r r e q u ir e d , c u t t i n g of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required f o r t h e work shall be supplied by the Contractor]. | Numbers | 20.00 | 16,383.88 | 3,27,677.6 |
| 58 | Excavation of pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, f o r erection o f colour light signals up to 4 aspects.[Foundation b o l t s , c e m e n t , M sand, stone jelly o f size 20/25mm d i a a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Numbers | 6.00 | 9,213.28 | 55,279.68 |
| 59 | "Erection of surface base, signal pole, mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED / filament b u l b s ) with lenses, t r i p l e p o l e l a m p holder, filament switching u n i t s , C L S transformer, current regulators (whichever is applicable), fixing of ladder w i t h platform complete and concreting o f l a d d e r s h o e , fi x i n g o f number plates, marker board, lens guard, fixing of speed limit board wherever necessary, termination of tail cables, wiring o f signal unit with P V C wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole i n the signal pole t o prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, M sand, Signal Collar Rings, wire P V C 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead w o o l , paints PVC/Nylon sleeves, enameled n u m b e r plates. enameled marker boards, E W S locks, a n d all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 6.00 | 8,287.08 | 49,722.48 |
| 60 | "Excavation o f p i t a n d c a s t i n g concrete foundation a s p e r D r g , No.SG/CN/02/10 using metallic templates, f o r erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, M sand, stone j e l l y o f size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 2.00 | 4,645.17 | 9,290.34 |
| 61 | "Erection of Ground type shunt signal complete including surface base, signal pole, LED aspects/ l e n s e s , b u l b s w i t h holders (whichever is applicable), fixing of lens guards, number plate, termination o f tail cables, wiring o f signal unit w ith P V C wire 3/0.75mm copper, provision of EWS locks and painting of one coat of red oxide and two c o a t s o f Aluminium/ enamel paint. (Supply o f Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n this schedule).[Wire PVC 3/0.75mm c o p p e r , lens guards, E W S locks, Enameled number plates, bolts a n d nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]." | Numbers | 2.00 | 3,170.44 | 6,340.88 |
| 62 | Fixing of Offset brackets using 'U' bolts and nuts, erection of Post type shunt Signals, termination o f t a i l c a b l e s a n d w i r i n g using wire PVC 3/0.75mm copper, provision of EWS l o c k and painting of one coat of red-"oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes o n t h e C L S post a n d provision o f a through bolt with nut to prevent the Off-setbracket from slipping down." | Numbers | 6.00 | 2,306.03 | 13,836.18 |
| 63 | F i x i n g a n d w i r i n g o f S t e n c i l t y p e route indicator[Fixing bolts and nuts, EWS locks wires PVC 3/0.75mm & 16/0.2mm copper, wire mesh, P V C / N y l o n s l e e v e s , p a i n t s a n d a l l other miscellaneous materials shall be supplied by the Contractor] | Numbers | 6.00 | 3,135.75 | 18,814.5 |
| 64 | Fixing of Offset brackets using 'U' bolts and nuts, erection o f Calling O n Signals/ 'A' marker lights, termination of tail cables and wiring using w ire P V C 3/0.75mm copper, provision o f EWS l o c k , n u m b e r plates/ marker b o a r d s and painting. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down.(Supply o f Calling o n Signal/ 'A' marker light, L E D aspects/holders & bulbs and Off set brackets is not covered in this schedule). ['U' bolts and nuts, through bolts with nut, wire P V C 3/0.75mm copper, E W S lock, Enameled number plates, w ire mesh, PVC/Nylon sleeves, paints a n d a l l other miscellaneous materials shall be supplied by the contractor]. | Numbers | 6.00 | 2,081.25 | 12,487.5 |
| 65 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) | Numbers | 1.00 | 8,914.5 | 8,914.5 |
| 66 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling p l a n . T h i s w o r k includes provision of double bonding and parallel jumpers, provision o f bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers | 1.00 | 4,234.65 | 4,234.65 |
| 67 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling p l a n . T h i s w o r k includes provision of double bonding and parallel jumpers, provision o f bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d connections wherever necessary using 2c x 2.5 sq.mm cable b)Alteration to existing track circuits at relay end | Numbers | 1.00 | 3,850.31 | 3,850.31 |
| 68 | Excavation o f pit, casting concrete foundation and erection o f apparatus case full size a s per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for t h e bac k door, fixing o f o n e h a r d w o o d shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation b o l t s & n u t s , ' E ' type locks, cement, M sand, stone jelly o f size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fi x i n g b o l t s & n u t s a n d a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.] | Numbers | 4.00 | 11,333.1 | 45,332.4 |
| 69 | "Excavation o f pit, casting concrete foundation and erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & n u t s a n d a l l o t h e r miscellaneous materials required f o r t h e work shall b e supplied by the Contractor]""" | Numbers | 4.00 | 8,787.04 | 35,148.16 |
| 70 | Termination o f n e w main/tail c a b l e s o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r a p p r o v e d circuit diagram. T h e terminal particulars a r e to be repainted /corrected o n t h e doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created for entry o f n e w cables in the apparatus cases w ith masonry brick work and sealing the bottom o f the apparatus cases/ cable termination racks w ith cable compound. [Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall b e supplied b y the contractor]. (Per Unit = Per Terminal block) | Per Unit | 836.00 | 73.59 | 61,521.24 |
| 71 | Termination o f main, tail, Signaling and power cables a n d internal w i r i n g on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing o f terminals/ fuse blocks o n t h e terminal b o a r d , drilling of necessary h o l e s , termination o f cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves andalso on the inner side o f t h e d o o r s of apparatus cases. After terminations are "over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." a)Termination o n 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 520.00 | 172.14 | 89,512.8 |
| 72 | Termination o f main, tail, Signaling and power cables a n d internal w i r i n g on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing o f terminals/ fuse blocks o n t h e terminal b o a r d , drilling of necessary h o l e s , termination o f cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves andalso on the inner side o f t h e d o o r s of apparatus cases. After terminations are "over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." b)Termination o n PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 20.00 | 209.93 | 4,198.6 |
| 73 | Termination o f main, tail, Signaling and power cables a n d internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound. a)Termination of cables on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 140.00 | 151.09 | 21,152.6 |
| 74 | Termination o f main, tail, Signaling and power cables a n d internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound. b)Termination of cables o n PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 12.00 | 188.86 | 2,266.32 |
| 75 | Installation of charged secondary cells of the f o l l o w i n g c a p a c i t i e s i n a p p a r a t u s cases, connecting them with strips, wiring with wire PVC 3/0.75mm copper and termination. This work also includes charging of cells through reputed agencies. The details of the batteries shall be written on the inside of the doors of the apparatus cases.(Supply of secondary cells is not included in this schedule).[Wire PVC 3/0.75mm copper, connecting strips, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. b)Installation of 2V-40/80AH cells in apparatus cases(Per Unit = Per Cell) | Per Unit | 10.00 | 491.59 | 4,915.9 |
| 76 | Provision of signaling arrangement during Non- Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site.(Supply of relay rack, relays, and SM slide instrument is not included in this schedule).[All other miscellaneous materials required for the work shall be supplied by the Contractor]. | Station | 1.00 | 33,631.06 | 33,631.06 |
| 77 | Releasing of existing apparatus cases (Full/ Half/ Quarter size) without damage after releasing the s h e l f p l a n k s , Terminal blocks, F u s e Blocks, Terminal Boards, Relays o f a l l t y p e s EKTs, Secondary Cells, power equipments, ' E ' type l o c k s , e t c . , and breaking t h e concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The r e l e a s e d m a t e r i a l s s h a l l be accounted and stacked a t a place a s instructed by Railway representative at site. | Numbers | 2.00 | 3,006.71 | 6,013.42 |
| 78 | Breaking of concrete and releasing the existing cable termination boxes, after releasing the base plank, Terminal blocks, Fuse Blocks, Terminal B o a r d s , c u t rails, pipes, e t c . , c l o s i n g the resultant pits and consolidating i t b y ramming a n d levelling. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 19.00 | 2,004.94 | 38,093.86 |
| 79 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Ro u t e Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking t h e concrete foundation,closing the resultant pit and resurfacing it by ramming and levelling. | Numbers | 4.00 | 3,083.03 | 12,332.12 |
| 80 | Dismantling a n d releasing o f existing Point m a c h i n e s ( a l l t y p e s ) i n c l u d i n g ground connections a n d o t h e r accessories available complete without a n y damage t o the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Numbers | 19.00 | 2,698.69 | 51,275.11 |
| 81 | "Releasing of existing ground type shunt signals along with surface base, signal post etc carefully without a n y damage, accounting a n d stacking them neatly at a place as instructed b y Railway representative a t site. T h e w ork also includes breaking a n d removal o f concrete foundation and refilling of the resultant pit by ramming and levelling." | Numbers | 1.00 | 2,196.41 | 2,196.41 |
| 82 | Releasing of existing TLD boxes with stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 8.00 | 159.29 | 1,274.32 |
| Schedule total | ₹44,50,583.08 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCcorrectionslipsupload.pdf
GCC2022.pdf
SOR2022BOOKLET.pdf
PV1.pdf
CableCutpenaltyLetter.pdf
ATCandScope.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .