Loading…
Loading…
Tender Value
₹15.3 Cr
EMD Value
₹15.3 L
Closing Date
13 Oct 2026, 6:00 pm
Executive Engineer,Tapi (R & B) Division,Vyara
Construction of Taluka Seva Sadan Valod Ta. Valod Dist. Tapi
345775
15 OF 2026-27
Open
Civil Works - Buildings
Works
Tapi
18 documents required · 17 mandatory · 1 optional
₹18,000
Executive Engineer,Tapi (R & B) Division,Vyara
₹15.3 L
18 Sept 2026
18 Sept 2026
18 Sept 2026
13 Oct 2026
18 Sept 2026
No figures
1 Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful 4341.00 Cumt 120.01
materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
2 Excavation for foundation upto 1.5 to 3 m depth including sorting out and stacking of 2965.00 Cumt 166.44
useful materials and disposing off the excavated stuff upto 50 Meter lead.(C) Dense or
3 Filling in foundation and plinth with sand in layers of 20 cm. Thickness including 388.00 Cumt 471.69
watering ramming and consolidating etc. comp.
including ramming watering and consolidating etc. complete
5 Anti-Termite System:Providing and laying of permanent piping technology anti-termite 1916.00 Sqmt 63.63
treatment before flooring work by installing LLDP (Low linear density polyethylene)
tube of 8 mm O.D. & 6.4 mm 1.D. with inbuilt pressure compensation chip every 30 cm
interval in the tube, having working pressure of 2 Kg/cm2 and release rate of
Itr/hour fixed by P-clips and nails. The LLDP pipe shall be installed at the entire
periphery of the building and at internal network of building at a depth of 20 to 200 mm
under floor at every 2 to 3 mtr. c/c distance (adjusted as per building layout ) & Ends of
loop pass through a PVC elbow of minimum 32 mm ID at junction box of wall and floor
level, entering into a steel reinforced grooved flexible pipe of minimum 22 mm ID
leading into junction box and the loops shall terminate in junction boxes & test every
junction during injecting chemicals for termite control treatment. The anti termite
chemical Imidacloprid 30.5% SC mix as per IS- 6313 (part III) shall be injected by the
pressure pump diluted with water @ 10.5 ml/5 ltr of water at the rate of 2 Kg/sq.cm @
5 Ltr/SMT. The contractor shall submit approved line plan for piping system and
junction boxes dully approved by Engineer-in-Charge with bond of 5 year
warranty.(II)Anti Termite chemical injected area (Chemical injecting incl. labour cost)
6 Filling available excavated earth (excluding rock) in trenches. plinth, sides of 3572.00 Cumt 133.65
foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited
layer by ramming and watering.
7 Providing and laying controlled cement concrete M.150 and curing complete including 675.00 Cumt 4007.50
the cost of formwork and excluding reinforcement for reinforced concrete work in (A)
Foundations and plinth pcc
8 Providing and laying controlled cement concrete M.250 and curing complete including 1479.50 Cumt 4712.66
the cost of formwork and excluding reinforcement for reinforced concrete work in (A)
Foundations, footings, and Mass concrete. footing
9 Providing and laying controlled cement concrete M-250 and curing complete including 106.07 Cumt 7658.34
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in (d) columns Up to Ground level.
Item Rate In
Description of Item Quantity Unit Amount
No figures
10 Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- machine cut 344.50 Cumt 3080.90
stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork
in (A) Foundation and Plinth
11 Providing and laying controlled cement concrete M-200 and curing complete including 243.00 Cumt 7633.58
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts G.FLOOR and F.floor
12 Providing and laying controlled cement concrete M-200 and curing complete including 89.00 Cumt 7674.99
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts 2nd FLOOR
13 Providing and laying controlled cement concrete M-200 and curing complete including 50.00 Cumt 7716.40
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts 3rd FLOOR
14 Providing and laying controlled cement concrete M-250 and curing complete including 334.50 Cumt 6077.17
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Ground & Plinth BEAMS
15 Providing and laying controlled cement concrete M-150 and curing complete including 300.50 Cumt 5318.66
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in plinth Slab
16 Providing and laying controlled cement concrete M.200 and curing complete including 527.50 Cumt 6303.41
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
Ground floor Beams and First floor
17 Providing and laying controlled cement concrete M.200 and curing complete including 262.00 Cumt 6343.81
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
S.floor Beams,
18 Providing and laying controlled cement concrete M.200 and curing complete including 31.00 Cumt 6385.22
the cost of formwork and excluding reinforcement for reinforced concrete work in ©
3rd floor Beams,
19 Providing and laying controlled cement concrete M-200 and curing etc. complete 51.50 Cumt 6903.35
including the cost of form work and reinforcement for reinforced concrete work in (c)
Chhajja for Ground floor and first floor
20 Providing and laying controlled cement concrete M-200 and curing etc. complete 25.00 Cumt 6944.76
including the cost of form work and reinforcement for reinforced concrete work in (c)
Chhajja S.floor
21 Providing and laying controlled cement concrete M-200 and curing etc. complete 1.00 Cumt 6986.17
including the cost of form work and reinforcement for reinforced concrete work in (c)
Chhajja 3rd floor
22 Providing and laying controlled cement concrete M-200 and curing etc. complete 28.50 Cumt 8726.40
including the cost of form work and reinforcement for reinforced concrete work in (c)
Lintal for Ground floor and first floor
23 Providing and laying controlled cement concrete M-200 and curing etc. complete 14.00 Cumt 8767.81
including the cost of form work and reinforcement for reinforced concrete work in (c)
Lintal for S.floor
24 Providing and laying controlled cement concrete M-200 and curing etc. complete 1.00 Cumt 8809.22
including the cost of form work and reinforcement for reinforced concrete work in (c)
Lintal for 3rd floor
Item Rate In
Description of Item Quantity Unit Amount
No figures
25 Providing and laying controlled cement concrete M.200 and curing complete including 547.00 Cumt 6705.39
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
Ground and first floor Slab
26 Providing and laying controlled cement concrete M.200 and curing complete including 272.00 Cumt 6746.80
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
Second Floor slab
27 Providing and laying controlled cement concrete M.200 and curing complete including 13.00 Cumt 6787.20
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
Third Floor slab
28 Providing and laying controlled cement concrete M-200 and curing etc. complete 17.50 Cumt 7181.10
including the cost of form work and excluding the cost of reinforcement etc. complete in
(E) Stair case for Ground Floor to first floor and first floor and second floor
29 Providing and laying controlled cement concrete M-200 and curing etc. complete 5.00 Cumt 7222.51
including the cost of form work and excluding the cost of reinforcement etc. complete in
(E) Stair case for second Floor to Third Floor
30 Providing and laying controlled cement concrete M.200 and curing complete excluding 76.00 Cumt 8971.83
the cost of formwork and reinforcement for reinforced concrete work in (B) Walls, from
top of foundation level upto floor two level
31 Providing and laying controlled cement concrete M.200 and curing complete excluding 20.00 Cumt 9013.24
the cost of formwork and reinforcement for reinforced concrete work in (B) Walls, from
top of foundation level for Second Floor
32 Providing and laying controlled cement concrete M.200 and curing complete excluding 18.00 Cumt 9054.65
the cost of formwork and reinforcement for reinforced concrete work in (B) Walls, from
top of foundation level for Third Floor
33 Providing and fixing 90 cm high Stainless steel railing made from anticorrosive 304 106.00 Rmt 3719.83
grade S S pipe of 50 mm dia (16Gauge) as hand rail with S S 304 grade Baluster of
mm dia (16Gauge) as a vertical support fixed in RCC slab at 1.2m c/c including three
horizontal S S pipes of 25 mm dia (16Gauge) at eqal distance fixed by 18.75 mm dia
(16Gauge) S S pipe with baluster including accessories as per detailed drawing as
directed etc. complete.
34 Providing TMT FE 500D bar reinforcement for RCC work including bending & placing in 519661.00 Kg 77.47
position complete up to All floor Level
Item Rate In
Description of Item Quantity Unit Amount
No figures
35 Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular 2980.00 Sqmt 1674.15
edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight
calcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per B.S. 476 part
IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC.for the best
thermal Insulation. The Light weight calcium Silicate tile shall be of approved texture Fine
fissured/ Spintone/ Cosmos having NRC value of 0.5 & Globe having NRC value of 0.75 NRC or
equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking
metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including
both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size
of 24 X 38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross
‘T’ of size 24 X 28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced
between main 'T' at 600mm centre to centre to form agrid of 1200x600mm and size 24x48mm
made of 0.30mm thick (Minimum) sheet to be interlocked at middle of the 1200x600mm panel
to form grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle
pre-coated steel of size (24x24x3000mm made of 0.40mm thick (minimum) sheet with the help
of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and
laying 15mm thick densified edges light weight calcium silicate ceiling tiles of approved texture
(Fine fissured/Cosmos/Spintone) in the grid including cutting/making opening for services like
diffusers, grills, light fittings, fixtures, smoke dtectors etc., wheneveer required, Main 'T' runners
to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm fixed to ceiling with
12.5mm dia and 50mm long dash fasterners, 4mm G.I. adjustable rods with galvanized steel evel
clips of size 85x30x0.8mm, spaced at 1200mm center to centre long main 'T' bottom exposed
with 24mm of all T-sections and also provide additional frame work and suspended G.I. support
as required height shall be pre-painted with polyester baked paint, for all heights, as per
specifications, drawings and as directed by engineer-in-charge. Note:- Only calcium silicate false
ceiling area will be measured from wall to wall. No deducation shall be made for exposed
frames/opening (cut outs) having area less than 0.30sqm. The calcium silicate ceiling tiles shall
fissured/Spintone/Cosmos and 0.75 NRC for Globe, light reflection 85% non-combustible as per
B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity. 0.043 w/m KC
for the best thermal Insulation.
36 Brick work using common burnt clay building bricks having crushing strength not less 147.00 Cumt 4121.55
than 35 kg/sq.cm. in foundation and plinth in cement mortar 1:6 (1 cement : 6 fine sand)
Conventional
37 Brick work using common burnt clay building bricks having crushing strength not less 737.50 Cumt 4403.40
than 35 Kg/Sq.cm. in super structure above plinth level upto floor two level in cement
mortar 1:6 (1cement : 6 fine sand) Conventional Ground floor & First floor
38 Brick work using common burnt clay building bricks having crushing strength not less 214.00 Cumt 4444.59
than 35 Kg/Sq.cm. in super structure above plinth level upto floor two level in cement
mortar 1:6 (1cement : 6 fine sand)Conventional {Second floor}
39 Brick work using common burnt clay building bricks having crushing strength not less 112.00 Cumt 4485.77
than 35 Kg/Sq.cm. in super structure above plinth level upto floor two level in cement
mortar 1:6 (1cement : 6 fine sand)Conventional {Third floor}
40 Half brick masonry in common brunt clay building bricks having crushing strength not 1439.00 Sqmt 669.34
less than 35Kg/Sm. In C.M 1:4( 1cement : 4 coarse sand) in super structure.
Conventional for Ground floor & First floor
41 Half brick masonry in common brunt clay building having crushing strength not less 681.00 Sqmt 675.49
than 35Kg/Sm. In C.M 1:4( 1cement : 4 coarse sand) in super structure.Conventional for
Second Floor
42 Providing and fixing 150 mm wide, approved quality chicken wire mesh at junction of 2060.00 Sqmt 295.12
brick work and RCC work or two dissimilar surfaces, at all heights fixed by nails, rowal
plugs or tag by cement mortar 1:3 before applying the plaster, including curing, as per
engineer charged.
43 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or 7337.00 Sqmt 178.89
half brick walls for interior plastering upto floor two level and finished even and smooth
in (ii) Cement mortar 1:4 (1-cement :4-sand) for G. loor and F. loor
Item Rate In
Description of Item Quantity Unit Amount
No figures
44 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or 3482.00 Sqmt 206.28
half brick walls for interior plastering upto floor two level and finished even and smooth
in (ii) Cement mortar 1:4 (1-cement :4-sand) for S. loor
45 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or 606.00 Sqmt 332.65
half brick walls for interior plastering upto floor two level and finished even and smooth
in (ii) Cement mortar 1:4 (1-cement :4-sand) for 3rd loor
46 Providing 10 mm. Thick smooth cement plaster in single coat for plastering on ceiling 4032.00 Sqmt 204.63
and soffits of stairs and finished even and smooth in : (I) Cement mortar 1:4 (1 cement
: 4 sand) with floting coat of neat cement slurry etc. complete.Ground Floor & First
47 Providing 10 mm. Thick smooth cement plaster in single coat for plastering on ceiling 1963.00 Sqmt 228.60
and soffits of stairs and finished even and smooth in : (I) Cement mortar 1:4 (1 cement
: 4 sand) with floting coat of neat cement slurry etc. complete. Second Floor
48 Providing 10 mm. Thick smooth cement plaster in single coat for plastering on ceiling 56.00 Sqmt 276.56
and soffits of stairs and finished even and smooth in : (I) Cement mortar 1:4 (1 cement
: 4 sand) with floting coat of neat cement slurry etc. complete. Third Floor
49 20mm thick double coat sand faced cement gutka plaster on walls upto height 10 metres 7123.00 Sqmt 337.52
above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-
sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) including 1cm x 1cm
grooves etc. complete.
50 Providing throating or plaster drip and moulding to R.C.C. Chhajja. 1096.00 Rmt 43.22
51 Applying two coats of putty & two coats of primer of approved brand and manufacture 17221.00 Sqmt 40.59
on new wall surface to give an even shade including thoroughly brushing the surface
free from mortar dropping and other foreign matter and sand papered smooth.
52 Wall painting (two coats) with plastic emulsion paint of approved brand and 11228.00 Sqmt 81.38
manufacture on undecorated wall surface to give an even shade including throughly
brushing the surface free from mortar droppings and other foreign matter and sand
papered smooth.
53 Wall painting (two coats) with plastic emulsion paint of approved brand and 6049.00 Sqmt 86.92
manufacture on undecorated ceiling surface to give an even shade including throughly
brushing the surface free from mortar droppings and other foreign matter and sand
papered smooth.
54 Finishing wall with Weather proof exterior 100% acrylic emulsion paint With one coat 7231.00 Sqmt 117.40
of primer on wall surface to give an required shape even shade after thoroughly
brushing the surface to remove all dirt, and remains of loose powdered materials.etc
complete for All floor
55 Providing And filling with good quality cinder(steam coal) as directed by engineer in 67.00 Cumt 589.84
charge in sunks in layers of 15 cm thick,including watering,placing ,ramming well etc as
directed, for all floor.
Item Rate In
Description of Item Quantity Unit Amount
No figures
56 Providing and laying water proofing treatment by conventional method including 267.00 sqmt 1014.04
cleaning the slab surface by wire brush as directed including provding first layer of C.M.
1:4 of 40 mm thickness mixed with water proofing compound at rate prescribed by
manufacturer, including putting of brick bats of average thickness 40 mm Well
immerssed in water laid uniformly on first layer of mortar including applying cement
slurry @ rate of 0.08 bag/sqm. on fixed layer of brick bats including maintaining
necessary slope, in second layer 40 mm thick C.M 1:4 mixed with water proofing
compound as directed, including finishing smooth with cement slurry as directed
57 Providing and laying controlled cement concrete M-200 for RCC work and curing 25.00 Cumt 5451.98
complete including the cost of form work but excluding the cost of reinforced concrete
work in coping on Ground Floor and first floor
58 Providing and laying controlled cement concrete M-200 for RCC work and curing 10.98 Cumt 5467.07
complete including the cost of form work but excluding the cost of reinforced concrete
work in coping on 2nd Floor
59 Providing and laying controlled cement concrete M-200 for RCC work and curing 9.00 Cumt 5534.80
complete including the cost of form work but excluding the cost of reinforced concrete
work in coping on 3rd Floor
60 Providing and fixing window having extruded aluminum Colour anodized section frame 798.00 Sqmt 1583.95
main outer size 95mm x 24mm x 1.17mm @ wt.of 0.738 Kg/mt , horizontal Three track
member size 92mm x 31.75mm x 1.30mm,@ Wt.1.07 Kg/mt , vertical member of size
92mm x 31.75mm x 1.50mm @ Wt. 1.06 Kg/mt with sliding shutters of horizontal
member size 40 mmx18mm x1.29mm @ wt.of 0.456 Kg/mt, vertical member of size
40mm x 18mm x 1.29 mm @ wt.of 0.456Kg/mt/ with 5 mm thick transparent bronze
colour tinted float glass with powder coated aluminum fittings and fixtures and
transparent silicon sealant glass fixing to frame as per details etc
61 Providing and fixing window having extruded aluminum Colour anodized section frame 21.00 Sqmt 1713.70
main outer size 63.50 x 38.10 x 1.95 mm,@ Wt 1.094 Kg / Rmt, horizontal two track
member size 61.85 mm x 31.75 mm x 1.20mm @ wt.of 0.695 Kg/mt, vertical member of
size 61.85 mm x 31.75mm x 1.30 mm @ wt.of 0.659 Kg/mt with sliding shutters of
horizontal member size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt, vertical member
of size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt, @ Wt. 0.457 Kg/mt with 5 mm
thick transparent bronze colour tinted float glass with powder coated aluminum fittings
and fixtures and transparent silicon sealant glass fixing to frame as per details etc
complete for window.
62 Providing & fixing in position glass panel with standard extruded colored anodized 711.00 Sqmt 2564.39
aluminum frame size 63mm x 38mm x 2mm thick make vertical and horizontal grid
distance as shown in drawing with 12mm thick toughen glass directed with glass film,
fixed with transparent silicon rubber gasket in panel with glazing clips 19 mm x
17.3mmx1.2mm in size including fixtures and fastening with required all labour and
equipment and including rebar up to slab level in half partition and as per detailed
drawing as directed with all lead and lift. for FG
Item Rate In
Description of Item Quantity Unit Amount
No figures
63 Providing and fixing window having extruded aluminum Colour anodized section frame 335.00 Sqmt 1525.00
of size 63.50 x 38.10 x 1.95 mm,@ Wt 1.094Kg / Rmt with colour anodized alluminium
frame with 5 mm thick transparent bronze colour tinted float glass as with powder
coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to
frame as perdetails etc details etc complete for Fix window
64 Providing & Fixing in position standard extruded approved colour anodised Aluminum 26.00 Sqmt 2690.74
Ventilation with outer frame 65 x 25 x 1.50 mm Frame @ Wt 0.833 kg/Rmt with 3 mm
thick fixed Bajari glass a alluminium strip blade fixed or adjestable ventilation,Fixed
glass, exhuast fan including all required materials, fixtures, fastenning, labours and
equipments as per detailed drawing as directed. For Ventilation
65 Providing and fixing a 65mm thick double door shutter with an anodized aluminum 17.00 Sqmt 8067.88
frame made from equivalent door section No. 19552 (minimum weight 1.1 kg/m) with
non-teakwood inserts for hinge grip, frame size 38mm x 63.5mm. The double shutter
entrance door includes floor springs, pivoted flush shutters made of teakwood styles
(5cm x 15cm) on one shutter and six horizontally spaced teakwood rails (5cm x 5cm) on
the other shutter, both covered with 6mm thick waterproof ply on both sides and
finished with 1mm thick laminate of approved color and shade. The door is fitted with
60cm long stainless steel handles on both shutters, a locking system, and stainless steel
fixtures and fastenings. The design, color, and pattern shall be as approved by the
architect or as directed by the Engineer-in-Charge, inclusive of all materials, labor, and
equipment to complete the work as specified.
66 Providing and fixing 38 mm thick flush single door shutter with Fixed Glass, solid core 303.00 Sqmt 4757.10
with Anodized Aluminium section (jindal door section no 19552-weight not less than
1.1 kg/mt ) frame size 63.5mm x 38mm inserted Non teak wood frame inside the
aluminium section for durable grip of hinges & Single shutter with required teakwood
batten having 1mm thick lamination on both side, Durable Grip shall be providing with
both side 15cm long stainless steel handle and necessary Locking system of Godrej,
,fixtures & fastenings etc. directed by engineer in charge. D1
67 Providing and fixing Single or Double Shutter FRP frame size 100x50 mm and 28mm 60.00 Sqmt 2377.76
thick FRP depress panel shutter having extra reinforcement on sides & edges in Gel coat
finish. The core of the shutter & frame is to be filed up with injected fire retardant grade
polyurethene foam done in situ alongwith embedded wooden pieces for stiffening &
also taking hinges & fintures. The whole FRP frame & shutter is to be water proof
weather proof, termite proof & resistance to mild acid/alkali. Rates are to be inclusive of
S.S hinges with necessary screws & alluminium fixtures & fastenings & fastener sleeve.
Item Rate In
Description of Item Quantity Unit Amount
No figures
68 P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement 4876.50 Sqmt 1432.78
mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by
adhesive material including dismentaling of existing flooring and jointed with color
cement slurry including finised with flush pointing & cleaning the surface etc. complete
for antiskit
69 Providing and laying Vitrified tiles 8 to 10 mm thick , 36'' x 36'' in flooring treads of 1421.50 Sqmt 1521.73
steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse
sand ) finishing with flush pointing in white cement.
70 Providing and laying machine cut free edge machine Double polished Green marble 319.00 Sqmt 1420.06
18mm to 25mm thick finished treads and risers in with 1cm projecting, nozing rounded
moulding in tread laid over 12 mm (av.) thick bases of cement mortar 1:6 (1-cement : 6-
coarse sand) jointed with grey or colour cement slurry including rubbing and polishing
incl. making Three No.s of grooves of size 3mm X 3mm along the length of treads etc.
71 P & L Mate Finished antiskid ceramic tiles 30x30 cm size 6 mm thick in flooring treads 187.00 Sqmt 929.39
of steps and landing laid on a bed of 12 mm thick cement mortar 1:3(1-cement:3-coarse
sand)finishing with flush pointing in white cement
72 Providing and laying coloured premium printed glazed tiles of the size 300 mm x 200 838.00 Sqmt 1477.25
mm x 8 mm / 300 mm x 450 mm x 8 mm ,300 mm x 300 mm x 8 mmin skirting, risers of
steps and dedo on 10 mm. thick cement plaster 1:3 (1 cement : 3 coarse sand) & jointed
with white cement slurry.
73 Providing Plinth Protection to Building including excavation in ordinary soil and laying 634.00 Sqmt 2473.59
cement concrete 1:3:6 using stone aggregates of 40mm nominal size in foundation layer
125 mm thick+ 125mm thick sand layer below pre-cast Rubber Dye inter locking
concrete block 60mm thick with grade of concrete M300 pneumatic compressed by
mechanically pressed and as per approved design including 75mm Sand layer for
levelling and filling the joint with sand in proper line and level etc. complete, Including
Providing and fixing pre-cast concrete kerb stone of grey cement based concrete block
30cm length, 30cm height and 15cm thick made of M250 grade concrete as per
approved design and including excavation for fixing in proper line and level, filling the
joint with C:M 1:3 (1cement:3 fine sand) etc. complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
74 Providing and laying China mosaic type water proofing treatment on terrace including 2077.00 Sqmt 1113.02
cleaning the surface by wire brush as directed including applying neat cement slurry @
2.75 Kg/Sq.smt. mixed with water proofing compound after cleaning the surface, laying
cement concrete using brickbats 25 to 100mm size well immersed in water with 50% of
cement mortar 1:5 (1 cement :5 coarse sabd) mixed with water proofing compound over
20mm thick layers of cement mortar 1:5 (1 cement :5 sand) to required slope including
rounding of junctions of walls and slabs and after two days of proper curing, applying
second coat of cement slurry finishing the surface with rate 20mm thick cement mortar
1:4 and china mosaic tiles and finally finishing the surface with white cement slurry and
after finishing the whole terrace shall be flooded with water for a period of two weeks.
75 Providing and fixing polished 18 mm thick Granite stone with full round edge and 1257.00 Sqmt 2475.51
polished of approved quality in clading on sill and around the doors/ windows/
ventilation with 20 mm thick cement plaster CM (1:4) and fixing with cement slurry &
adhesive including moulding of exposed edges as directed by engineering in charge etc.
76 Providing and fixing M.S Safty Grills having 16mm MS bar Horizontally at every equal 1004.00 Sqmt 3472.99
0.10m C/C distance and 2 no of bar Vertically at every equal 0.375m C/C distance Fixing
on around (5x40) mm Solid MS Patti including cutting, welding and fabrication etc;
including one coat of primer of approved quality and two coats of oil painting as per
detail drawing etc. complete as per directed Engineer in charge.
77 Providing erecting and fixing double coated Syntex PVC. (ISI) water tank of required 15000.00 Litre 3.95
capacity each with all necessary fittings and connection etc. complete on terrace.
78 Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe ( SCH- 40) for 170.00 Rmt 195.67
cold water including fittings make as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
79 Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for 140.00 Rmt 148.12
cold water including fittings make as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
80 Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for 240.00 Rmt 91.84
cold water including fittings make as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
Item Rate In
Description of Item Quantity Unit Amount
No figures
81 Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- 40) for 210.00 Rmt 72.65
cold water including fittings make as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
82 Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) 160.00 Rmt 834.38
conforming to IS 13592-1992 with one end plain and other end socketed with rubber
ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed
on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm
heigh at every 2000 mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement including cost of all materials.
83 Providing laying (to level or slopes) and jointing reinforced concrete Light duty non- 809.00 Rmt 678.01
pressure pipes I.S. class NP2 of the following internal diameter with collars and butt
ends prepared for collar joints including testing of joints complete.(D)
84 Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) 550.00 Rmt 857.65
conforming to IS 13592-1992 with one end plain and other end socketed with rubber
ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed
on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm
heigh at every 2000 mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement including cost of all materials.
85 Providing, laying and jointing in true line and level 75 mm dia. UPVC SWRType B pipe 150.00 Rmt 292.90
conforming to IS 13592-1992 with one end plain and other end socketed with rubbering
and fitting conforming to ISI 14735-1999 of approved make for drainage system pipe
line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on
wall using of PVC clamp at every 2000 mm c/c or shall be conceled in walss as directed
including necessary fittings such as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement including cost of all materials.
86 Providing and fixing in PVC SWR cowel went 75mm dia to pipes.(B) 75mm dia. 15.00 No 15.66
87 Providing and fixing in PVC SWR cowel went 110mm dia to pipes.(B) 110mm dia. 36.00 No 28.79
88 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with jali 90.00 No 585.37
of the following nominal diameter of self cleansing design with C.I scread down or
hinged grating including the cost of cutting and making good the walls.
Item Rate In
Description of Item Quantity Unit Amount
No figures
89 Providing and fixing wash down water closet (European type W C pan) with integral P 30.00 No 2983.54
and S trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement five
sand) including providing and fixing plastic seat cover for wash down WC with CP brass
hinges and rubber buffers back plastic seat and including providing and fixing PVC
flushing tank with a pair of C I or MS bracket with complete fitting such as lead valve
siphon 15 mm dia brass ball valve with polythene float CP brass handle unions and
couplings for connection with inlet out let and over flow pipes 40 mm dia porcelain
enameled flush bend including cutting holes in walls and making good the same
connection the flush bend with cistern and closet vitreous china.
{Hindustan, Cera, Parryware or equivalent }
90 Providing and fixing Urinal of approved quality including connection with trap and with 6.00 No 2593.68
integral longitudinal flush pipe.(A) Squating plate pattern white earthenware 550mm x
91 Providing and fixing polished 18 mm thick black granite with full round edge and double 17.00 Sqmt 2603.17
side polished of approved quality in between urinal and fixing with cement slurry &
adhesive including moulding of both exposed edges as directed by engineering in charge
etc. complete.
92 Providing and fixing brass screw down stop tap.(A) 15mm dia. 36.00 No 205.83
93 Providing and fixing ball cock of approved. quality as directed.(A) Copper Metal (ii) 3.00 No 189.84
94 Providing and fixing washbasin with single hole for pillar tap with C.I. or M.S. brackets 18.00 No 1649.22
painted white including Rubber plug, sutting holes and making good the same but
excluding fittings and also including rate of C.P. brass waste for washbasin or sink (A)
32mm dia. and M.I. fisher union for washbasin or sink. (A) 32mm dia.; (A) Vitreous
China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In white colour.
95 Providing and fixing 600mm x 450mm bevelled edge mirrror of superior glass mounted 18.00 No 852.76
on 6mm thick A.C. sheet or plywood sheet and fixing to wooden pluge with C.P. brass
screws and washers.
96 Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets fixed to 24.00 No 616.42
wooden plugs with C.P. brass scews (B) 600mm x 20mm size.
97 Providing and fixing screw down bib taps of following size.(A) Brass screw down bib tap 45.00 No 214.81
polished bright. (i) 20mm dia.
98 Providing and fixing pillar tap, capstan head, screw down high pressure with screws, 18.00 No 308.73
shanks and back nuts. (i) 15mm dia.
99 Providing and fixing in position 300 mm high, 150 mm wide English letters made from 240.00 No 707.00
1.0 mm thick stainless steel sheet as directed by Engineer in charge with all necessary
tools & plants etc. complete.
100 Providing and fixing Rubber plug for sink or wash basin. 18.00 No 17.15
101 Providing and fixing chromium plated brass half trun flush cock of approved quality 30.00 No 263.77
including fixing in pipe line etc. complete (ii) 25mm dia.
102 Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water 25.00 No 1246.92
tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight (i)
Square mouth traps (B) 150mm x 100mm size P or R type
Item Rate In
Description of Item Quantity Unit Amount
No figures
103 Constructing brick masonry chamber for underground C.I. Inspection chamber and 33.00 No 3172.41
bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 precast
RCC cover 455mm x 610mm intenal dimensions with frame (R.C.C. top slabe with 1:2:4
mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with
a floating coat of neat cement on walls and bed concrete etc. complete (i) Inside
dimensions 455mmx 610mm and 450mm deep for single pipe line.
104 Constructing brick masonry chamber for underground C.I. Inspection C.I. Inspection 23.00 No 3883.45
chamber and bends with briocks having croshing strength not less than 35Kg. Cm2 in
C.M. 1:5 precast RCC cover 500mmx 700mm intenal dimensions with frame (R.C.C. top
slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and bed concrete etc. complete (i)
Inside dimensions 500mmx 700mm and 450mm deep for single pipe line.
105 Extra over items for every additional depth of 0.1M. of part thereof beyond 450mm 25.00 Each 242.39
depth for Brick masonry chamber.(i) for 455mm x 610mm size.
106 Extra over items for every additional depth of 0.1M. of part thereof beyond 450mm 15.00 Each 264.86
depth for Brick masonry chamber.(i) for 500mm x 700mm size.
107 Providing cement vata (10cm x 10cm size) quarter round in cement mortar 1:1 140.00 Rmt 24.28
including neat cement finishing watering etc. Complete
108 Providing and fixing MS Ladder of required pattern with MS flats(30x3mm) or round or 600.00 Kg 115.14
square bars (12mm) at required spacing & with round headed bolts and nuts or screws
or welding including primer coat of approved quality and two coats of oil paintas as
directed by engineer in charge
109 Providing and fixing in position 150 mm high, English letters made from 1.0 mm thick 80.00 No 404.00
stainless steel sheet as directed by Engineer in charge with all necessary tools & plants
etc. complete.
110 Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60mm 1422.00 Sqmt 704.07
thick with grade of concrete M300 pnumatic compressed / vibrated mechanically and as
per approved design Confirming to IS 15658 : 2006 including 35 mm Sand layer for
levelling and filling the joint with sand in proper line and level as per guidlines of IRC :
SP 63-2018 etc. Complete.
111 Providing and fixing 0.60 meter wide Drinking platform including supplying and fixing 9.00 Sqmt 2831.03
granite stone of black or equivalant quality 18 mm thick mirror polished on top and
side posiition and vertical strip at front with cement slurry & adhesive including
moulding of both exposed edges over 25 mm thick kotah stone platform fixing in top
and sides and itermediates supports fixing with cement mortar and adhesive and
finishing all material and labour and assessories with necessary fitting complete etc.
112 Providing and laying and fixing 50 mm thick expansion joint by hydro cell semi rigid UV 39.00 Sqmt 1491.03
resistance with high performance laminated closed cell polythene foam joint filler in
sheet foam as directed, etc. complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
113 Applying and providing Expansion joint sealing System on 100 mm vide joint including 39.00 Sqmt 4772.00
cleaning of exansion joint by mechanical means provision of adhesive and flexible
membrane with required bond length as per menufracturer specification and 4mm thick
alluminium strip covering with one side sloted and bolted with suitable system,
inclusive of all manpower, machinery and material as per specification and as directed.
114 Providing and filling the expansion joint by Thioflex 600 polymer or equivalent confirm 39.00 Sqmt 515.39
to BS 4254-1983 as per required shade and manufactured specifi-cation by making
groove of 50 mm x 12.5 mm lather by cutting or by repairing groove and removing
mortar drop or any other foreign materials including applying primer and filling
required size (oversize of joint PU foam etc. complete.
115 Providing and fixing 25 cm Wide & 3mm thick exterior composite panel on existing 15.00 Sqmt 1054.34
expansion joint horizontally & vertically with all material, hardware, acessories &
fittings etc completed.
116 Providing and fixing coloured self adhesive PU-Tactile tile, ground surface indicators of 390.00 Sqmt 4791.44
Polyurethane) of size 300mm x 300mm for guiding/warning to the visually visitors in
the centre/side of the pedestrian/approach pathway as per specification and guidelines
complete in all respect to the entire satisfaction of in charge.
117 Providing and fixing acrylic multilingual Braille (raised dots) DIRECTIONAL 20.00 Nos 1765.48
SIGNBOARDS of size 225 x 150mm designed as per accessibility standards and having
3.5mm thick acrylic base plate with Upper Case San Serif words made of white acrylic
non glare cut out letters of height 15mm raised not less than 0.8mm above base plate
and the equivalent word written in Hindi with Devanagari non glare acrylic letters of
height 15mm raised not less than 0.8mm above base plate and having a non-glare
acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per
manufacturers specifications on the wall at the approved location and at a height of
1200mm from FFL complete as per design / specifications and guidelines as per the
entire satisfaction of the Engineer-in-charge
118 Providing & Fixing Braile Indicator Of Size 170 Mm X 35mm For Handrails Of The 120.00 Rmt 946.37
Approved Design And Make Have Braile Dots Raised 0.5 Mm Above Base Plate To Be
Installed At Specific Locations As Per Direction Of Engineer In Charge
119 Providing and fixing of conspectus tape 50mm width on of treads in staircase including 224.00 Rmt 304.01
cutting pasting etc. As per harmonised guidelines complete in all respect to the entire
satisfaction of engineer in charge.
120 Providing and Fixing a set of wall mounted 38 mm dia U shaped horizontal stainless 3.00 Set 2730.03
steel collapsible grab bar , 38mm vertical stainless steel fixed grab rail of grade SS
from round pipe supported and 75 mm dia 8 mm thick SS 304 base flange on wall
including anchor fasteners, nuts, accessories as per detailed drawing etc. complete as
directed by Architect or Engineer in charge.
121 Providing and fixing EURONICS 304 Stainless Steel Handicap Grab Bar, Size 600 6.00 Nos 3368.35
millimeter, including all necessary fittings and fixtures, complete as per the direction of
the Engineer-in-charge.
Item Rate In
Description of Item Quantity Unit Amount
No figures
122 Providing and fixing Semi Unitised Structural Glazed Facade / Curtain Glazing System 57.00 Sqmt 6602.37
using 24mm thick DGU units comprising 6mm thick Performance HS Glass + 12mm air
gap + 6mm thick Clear HS Glass with aluminium mullion and transom framework,
complete with powder coated aluminium sections, EPDM gaskets, structural silicone
sealant, VHB tape, cleats, brackets, anchor fasteners, hardware, scaffolding, labour,
transportation, testing and all necessary accessories required for complete installation,
strictly as per approved drawings, specifications and directions of Architect / Engineer-
123 Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size having weight not less than 1.00 Nos 958.17
124 Providing & erecting open well horizontal mono block pump set with cast iron body, 1.00 Nos 36107.50
complete for three phase submersible motor having [H]For 15 H.P,3 phase open well
horizontal mono block pump set suitable for 1600 LPM to 1025 LPM @ 33 to 42 MTR
head suitable for 65/80 mm dia delivery pipe
125 Supplying & erecting approvedmake 3 phase motor control cubicalpanel (Star-Delta) 1.00 Nos 19695.00
made from 16G.CRCA sheet duty painted with epoxy powder painted inside and outside
with hinged doors and locking arrangement, consisting suitable size of ON-OFF isolator
(AC- 3/23duty) main fuses,single phasing preventer cum water level, Guard(Compe
unit), Toggle switch to by pass Single phase preventercum WLG,indicating lamps forR-Y-
Bphases, over load relay.Automatic water level controller, Ammeter &Voltmeter each
on angle iron frame grouted on wall as overload relay,thermal/Electronics star delta
cutoff timer,start-stop push buttons.The isolator overload relay &cntractors
ofL&T,Siemens or Cuttler Hamer make only.Panel to be erected on angle iron frame
ground on wall (e)S/D upto 2.5 H.P.
126 Providing and fixing rolling shutters of approved make made of 80 mm wide M.S laths 5.00 Sqmt 3554.40
inter-locked together through heir entire length and jointed together at the ends by end
locks mounted on specially designed pipe shaft with bracket plates,guide channels and
arrangement for inside and outside locking with push-pull operation including the cost
of hood cover and sprig etc.complete(A) Shutters having width below 3.5M
127 Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and 17.00 Cumt 178.58
stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(B)
Dense or Hard soil
128 Constructing brick masonry chamber for underground C.I. Inspection chamber and 4.00 No. 7180.44
bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 C.I.
cover with frame (Light duty) 455mm x 610mm intenal dimensions, total weight of
cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. )
(R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate
20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar
1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc.
complete.(iii) Inside dimensions 600mm x 850 mm and 450mm deep for pipe lines
with three or more inlets.
Item Rate In
Description of Item Quantity Unit Amount
No figures
129 Box cutting the road surface to proper slope and camber for making a base for road 1796.00 Cum. 106.64
work including removing the excavated stuff and depositing on the road side slope as
directed upto 50Mt.lead.
130 Filling in plinth with sand under floors including watering ramming, consolidating and 348.00 Cum. 342.39
dressing complete
131 Construction of granular sub-base 150 mm thick by providing coarse graded machine 438.00 Cum. 723.16
crushed B.T. material satisfying MOST specification of grading I (B.T. stone aggregate
mm to 26.5 mm 35 %, 26.5 to 4.75 mm - 45 % and 2.36 mm below - 20 % )including
spreading in uniform layer with motor grader on prepared surface, mixing by mix in
place method with rotavator at OMC and compacting with vibratory roller to achieve the
desired density etc. complete.
132 Providing and laying wet mix macadam base course 250 mm thick using machine 579.00 Cum. 761.54
crushed B.T. chips as per required gradation mixing with required optimum quantity of
water, conveying the mix to site of work, spreading in to grade and camber with
mechanical paver and consolidation each layer with vibratory roller including cost of
material labour plant and equipment etc. complete.
133 Compaction and finishing of cement concrete road by trimix M.250 process providing 2206.00 Sqm. 63.63
extra Labour charges for the trimix vacume dewatering service process on cement
concrete road sutface by using vacuum dewatering pump floater surface vibrator
including making groves and rough finish to surface including leveling etc complete.
134 Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 716.00 Rmt. 370.68
30cm length,30cm height and 15cm thick of M250 grade concret as per approved design
and including excavation for fixing in proper line and level,filling the joint with C:M 1:3
(1cement:3fine sand) etc complete.
135 Drilling pilot borehole of size 250/300 mm at above site by mud flush direct rotery rig. 100.00 Rmt 853.25
136 Reaming of 250/300 mm dia.Pilot borehole to size 550 mm dia. Incliding assembling 15.00 Rmt 527.95
,lowering housing ,casing strainerpipers with gravel packing and clayball packing etc.
137 Development of cach water bearingzone coming across the full depth of tubewell by 1.00 Job 13212.90
lowering 100 mm dia.Droplineand 32 mm dia airline for each water bearing Zone with
suitabale capacity air compressar up to avilability of sand free discharge.
138 900 CFM /200 PSI capacity air compressar upto the availability of sand free discharge 1.00 Job 27206.17
for upto 250 mtrs
139 Supply of M.S. E.R.W. plain end medium duty pipe confirming to IS 4270/2001 with 100.00 Rmt 2440.64
latest amendments Of size 250 mm dia (minmum thicknes of 7.1 mm)
140 Screen Slotting of MS ERW balnce pipe with size of slot 6.75 cm X 6.35 cm X 3.12 mm for 200.00 slots 0.22
250 mm dia pipe
141 Supply of miscellenious bore material suitable to 250 mm dia pipes as following (A) MS 1.00 Pair 1912.70
Bore clamps made from M.S. plate with 3 holes on either side with nuts & bolts of std
make of size 900X100X16 mm flat suitable for 250 mm dia pipe.
Item Rate In
Description of Item Quantity Unit Amount
No figures
142 Supply of miscellenious bore material suitable to 250 mm dia pipes as following (B) MS 1.00 No 1385.64
Bore Plug having 100mm height made from M.S. plate with 3 holes at equal distance on
circumferrence for nut-bolts type, locking arrrangement with nuts-bolts & lock nuts of
std make complete from 5 mm thick M.S. plate suitable for 250mm dia pipe.
143 Supply of miscellenious bore material suitable to 250 mm dia pipes as following (C) MS 1.00 No 999.90
Bail Plug having length 0.45 mtr from medium class pipe as per I.S. suitable for 250 mm
144 Supply of miscellenious bore material suitable to 250 mm dia pipes as following (D) 168.00 NO 86.21
Steel bent plate suitable for ERW pipe for 250mm dia (size:200 X 150X6 mm)
146 Electrologging of Pilot bore hole with carting. 1.00 Job 10665.60
147 Geohydrological ground water investigation including vehicle charges for three phase 1.00 No 14220.80
DTH bore/DR tube well including water sample testing & chemical analysis
148 Providing, supplying and commissioning ISI mark CI D/F Reflux Valves of following 1.00 No 4753.30
class and diameter including all taxes, insurance, transportation, freight charges, octroi,
inspection charges, loading, unloading, conveyance to departmental stores stacking etc.
complete. Reflux valves PN 1 IS 5312 with ISI mark size: 100 mm
149 Providing and laying in trenches galvanised mild steel tubes (Midium grade) of the 100.00 Rmt 921.68
following nominal bore, and tube fitting (Earthwork in trenches to be measured and
paid for separately (H) 80mm
150 Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure 220.00 Rmt 339.05
poluthene pipes of the following outside Dia. Low densidy, complete with special falnge
compression type fittings, wall clipsetc. including making good the wall ceiling and
floor.(G)110 mm
151 Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure 260.00 Rmt 859.51
poluthene pipes of the following outside Dia. Low densidy, complete with special falnge
compression type fittings, wall clipsetc. including making good the wall ceiling and
floor.(G)160 mm
152 Providing junction for rain water juncton chamber of size 0.60x0.60x0.75m with 12.00 Nos. 9007.18
excavation of size 1.96x1.96 m & 0.15m thick c.c.1:2:4 bed concrete including brick
masonary wall in CM 1:6 of 0.75m height & 0.23m thick with 15mm thick cement plaster
inside & outside & 1.06x1.06 RCC (1:2:4) slab of thickness 0.15m with CRS steel and
0.60mx0.45m cast iron manhole cover with frame weight not less than 35 kg as per
directed by Engineer-in-charge
153 Providing and installation Recharge pit of “RAIWOHA” Make 3 layer RCC Precast 1.00 Nos. 109645.60
Injection well system of size 1.5 meter Dia. X 3.4 Meter Height rein forced concrete
precast three layer module with 6” dia x 12” dia. V wire screen of 0.75mm x 1.0 mm Slot
size in SS 304 material and 1.0 meter height with MS Top cover and required Air vent
including all necessary excavation and transportation at site including required filter
media for the recharge system as per site requirement.
Item Rate In
Description of Item Quantity Unit Amount
No figures
154 Drilling of min. 250 mm dia. bore hole in all strata including dualover burden strata by 30.00 Rmt 1270.58
combination DR/DTH rig including lowering 200 mm dia MS ERW pipes in bore hole
and testing etc.all work as per directed engineer incharge.
155 Supplying slotted PVC pipes of approved quality at site of work confirming to IS. 30.00 Rmt 555.50
1239/1974 180mm dia.
156 Cleaning & maintenance of system Including all Labour and replacing of Filter Media as 1.00 Nos 4646.00
Required for one year
157 Providing and laying controlled cement concrete M-250 and curing complete including 292.95 Cumt 6087.27
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Retaning wall
158 Providing and filter media 600mm thick as directed at the back of Protection Wall as 488.25 Sqmt 1279.96
per detailed specification.
159 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm 432.00 Rmt 669.63
dia 10 mt openable length having 50 no rounds per 6 mt length, upto 3mt height of wall
with existing angle iron (50mm x50mm x5mm )requird shaped As per Directed
Engeenier in charge. placed 2.4mt or 3.00mt apart and with 4 horizontal R.B.T.
reinforced barbed wire(3 mm) , stud tied with G.I. staples and G.I. clips to retain
horizontal, including necessary bolts or G.I.barbed wire tied to angle iron, all complete
as per direction of Engineer-in-charge, with reinforced barbed tape (R.B.T.)/Spring core
(2.5 mm thick) and weight 43.478 gm/meter at compound wall for ESR M4/ intakewell.
160 Constructing providing and fabricating cattle guard using channel section frame of size 27.00 Sqmt 5104.54
ISMC series 100 mm x 50 mm (Weight 9.20 kg/Rmt) and ISMC section 100 mm x 75mm
(weight 11.50 kg/Rmt) intermediate support for welding G.I.pipe at 12 Cm C/C of size
50 mm in a frame made of Channel section size 100 mm x 50 mm all round including
fixing the unit on prepared chamber of masonary wall using MS hold fast embeded in
masonary wall top as directed by Engineer in charge and as per drawing and necessary
required arrangement etc complete.
161 Providing and fixing decorative entrance gate made out of cast iron and various mild 2888.00 kg 167.66
steel tabular section combination , the Ornamental entrance gate should be fixed at
compound wall including pattern and die making , cutting , welding , grinding,
fabrication , fixing in position at compound wall with necessary pedestal, bearing block
and other locking arrangement. The entrance gate should be painted with two coats of
priming coat of paint, and two coat of oil paint etc complete. As per detail design and
instruction of architect.
162 Steel work, welded in built up sections framed work including cutting, hoisting, fixing in 12454.00 kg 91.08
position and applying a priming coat of read lead paint & two coat oil paint. (A)In beams
and joists, channels angles Tees, flats, with connecting plates or angle cleats as in main
and cross beams. Hip and jack rafters, purlins conneted to common rafters and the like..
Item Rate In
Description of Item Quantity Unit Amount
No figures
163 Providing and fixing of Ridge flashing for roof panel shall be made out of 0.5 mm thick 350.00 Sqm 867.39
pre coated GI sheet . The Precoated sheet shall be of minimum 240 mpa steel grade
confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per
IS:277:1992 , 5-7 microns epoxy primer on both side of the sheet and polyester top coat
15-18 micron. The PPGI Sheet shall have plastic protective guard film of minimum
microns to avoid scratches during transportation. The ridge shall be fixed to the steel
members by pop rivet or self drilling/self stitching fastners @ maximum 450 mm c/c
along length of capping/flashing etc complete .
164 Earthwork in cuting in all sorts of soil and soft murrum including conveying and 522.28 Cum 130.94
spreading the stuff, embankment as and where directed within 200meters from the end
of the cutting with all required lead and lift.
165 Earthwork for embankment including breaking clods, dressing with all lead and lift 10364.30 Cum 236.07
(excluding watering and consolidation)(E) From Borrow area within 3.0 Km. lead
166 Rolling and watering of Earth work in layers with power roller including filling in 10886.58 Cum 22.89
depressions which occure during the process.
167 Supply. installation, testing & commissioning of ISI approved electrical motor driven 1.00 No 98432.21
jockey pump set having 10.8 m3/hr. @ 70m head. The pump unit shall be a horizontally
direct mounted motor. Unit shall comprise the following minimum requirements: a)
Pump, b) Electric motor IE2, c) Foundation bolts, d) Mating flanges with gasket and
fasteners, e) Discharge gauges, etc. complete in all respect, with labour.
168 Supply, installation, testing & commissioning of Priming tank, HDPE type, 1000 litres, 1.00 No 25677.97
with necessary piping 100 mm size, G.I pipe for priming the pumps, pipe of with
butterfly valves for isolation, Water Filling to priming tank by piping min. 50 mm size,
with all complete.
169 Supply, installation, testing & commissioning of Manifold( surge vessel,)for fire hydrant 1.00 No 55635.60
system, min. 300 mm diameter, made from M.S plate, hydro tested to 15 kg./cm2. with
ball valves, header with couplings for fitting pressure switches, pressure gauges
etc.with necessary isolation valves with all complete.
170 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW piping, conforming to 7.00 Mtr 398.01
IS:1239, part-I, Heavy class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts & washers, 3 mm thick
gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 25 mm dia.
Item Rate In
Description of Item Quantity Unit Amount
No figures
171 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW piping, conforming to 30.00 Mtr 641.95
IS:1239, part-I, Heavy class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts & washers, 3 mm thick
gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 50 mm dia.
172 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW piping, conforming to 30.00 Mtr 1176.90
IS:1239, part-I, Heavy class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts & washers, 3 mm thick
gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 80 mm dia.
173 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW piping, conforming to 220.00 Mtr 1690.47
IS:1239, part-I, Heavy class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts & washers, 3 mm thick
gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 100 mm dia.
174 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW piping, conforming to 20.00 Mtr 2525.00
IS:1239, part-I, Heavy class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts & washers, 3 mm thick
gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 150 mm dia.
Item Rate In
Description of Item Quantity Unit Amount
No figures
175 Supply, fabrication & erection of aboveground G.I. 'C'-Class, ERW piping, conforming to 7.00 Mtr 3423.73
IS:1239, part-I, Heavy class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy class for size 150 mm dia. &
below & IS: 3589, for size 200 mm dia. above, flanges, nuts bolts & washers, 3 mm thick
gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 200 mm dia.
176 Supply, installtion, testing & commissioing of Underground GI (ERW) piping 20.00 Mtr 2020.00
conforming to IS:1239, part-I, Heavy class ('C' class) up to 150 mm dia. and IS:3589
Heavy class ('C' class), for 200 mm dia. & above, min. 6.35mm thickness including Heavy
class fittings, anti-corrosive tape of size 150 mm wide x 4 mm thick, wrapping & coating
with 13KV holiday testing . Rates shall include sand bedding of 75mm dia all around,
backfilling of the excavated including installation of heavy pipe fitting's, flanges, etc.
% of all the welded joints shall be done radiographically tested and 50% of the joints
radiographed shall be the "Field Joints". Hydrostatic testing for 2 hours at 150% of the
system pressure, hook-up etc., complete with all accessories as per approved drawings,
specicification and direction of the Engineer-in-Charge, with all complete. (Road
Crossing) 100 mm dia.
177 Supply, installtion, testing & commissioing of Underground GI (ERW) piping 10.00 Mtr 3047.12
conforming to IS:1239, part-I, Heavy class ('C' class) up to 150 mm dia. and IS:3589
Heavy class ('C' class), for 200 mm dia. & above, min. 6.35mm thickness including Heavy
class fittings, anti-corrosive tape of size 150 mm wide x 4 mm thick, wrapping & coating
with 13KV holiday testing . Rates shall include sand bedding of 75mm dia all around,
backfilling of the excavated including installation of heavy pipe fitting's, flanges, etc.
% of all the welded joints shall be done radiographically tested and 50% of the joints
radiographed shall be the "Field Joints". Hydrostatic testing for 2 hours at 150% of the
system pressure, hook-up etc., complete with all accessories as per approved drawings,
specicification and direction of the Engineer-in-Charge, with all complete. (Road
Crossing) 150 mm dia.
178 Design , Supply and installation of Safety Signage made of Zinc Sulphilde based glow in 7200.00 Sq. inch 9.41
dark , Rigid sheet with High Luminous property enclosed in a transperent weather proof
UV stabilized plastic pasted on 3 mm thick clear acrylic sheet such as EXITS,
EMERGENCY EXIT, DO NOT USE LIFT DURING FIRE, FLOOR MARKINGS, FIRE LIFT,
STAIRCASE EXIT, FIRE ALARM CALL POINT, FIRE HOSE REEL, FIRE HYDRANT POINT
179 Supply, installation, testing & commissioning of pressure switch. (Range 0 to 16 4.00 No 2824.58
Item Rate In
Description of Item Quantity Unit Amount
No figures
180 Supply, installation, testing & commissioning of 150 mm dia. dial Burdon Type 6.00 No 2738.99
Glycerine Filled pressure gauge with isolation ball valve arrangements with necessary
isolation valves with all complete.( Range 0 to 15 kg/cm2)
181 Supply, Installation, Testing & Commissioning of Cast iron body Butterfly valve 4.00 No 2011.45
according to IS: 13095, PN-1.6, Iron Disc for size 150 mm dia. & below Lever operated
and above 150 mm dia. Gear operated complete with mating flanges /ANSI class #
with bolts & nuts washers, rubber gaskets 3 mm thick, etc., with all complete. 50 mm dia.
182 Supply, Installation, Testing & Commissioning of Cast iron body Butterfly valve 2.00 No 2567.80
according to IS: 13095, PN-1.6, Iron Disc for size 150 mm dia. & below Lever operated
and above 150 mm dia. Gear operated complete with mating flanges /ANSI class #
with bolts & nuts washers, rubber gaskets 3 mm thick, etc., with all complete. 80 mm dia.
183 Supply, Installation, Testing & Commissioning of Cast iron body Butterfly valve 5.00 No 3124.15
according to IS: 13095, PN-1.6, Iron Disc for size 150 mm dia. & below Lever operated
and above 150 mm dia. Gear operated complete with mating flanges /ANSI class #
with bolts & nuts washers, rubber gaskets 3 mm thick, etc., with all complete. 100 mm
184 Supply, Installation, Testing & Commissioning of Cast iron body Butterfly valve 2.00 No 4493.65
according to IS: 13095, PN-1.6, Iron Disc for size 150 mm dia. & below Lever operated
and above 150 mm dia. Gear operated complete with mating flanges /ANSI class #
with bolts & nuts washers, rubber gaskets 3 mm thick, etc., with all complete. 150 mm
185 Supply, installation, testing & commissioning of Cast iron body Dual Plate Wafer Type 2.00 No 1540.68
NRV conf. to IS: 210, PN-1.6 complete with mating Flanges class # 150 with bolts & nuts,
washers, gaskets 3 mm thick, etc., with all complete Accessories 50 mm dia.
186 Supply, installation, testing & commissioning of Cast iron body Dual Plate Wafer Type 1.00 No 2225.42
NRV conf. to IS: 210, PN-1.6 complete with mating Flanges class # 150 with bolts & nuts,
washers, gaskets 3 mm thick, etc., with all complete Accessories 80 mm dia.
187 Supply, installation, testing & commissioning of Cast iron body Dual Plate Wafer Type 2.00 No 3166.96
NRV conf. to IS: 210, PN-1.6 complete with mating Flanges class # 150 with bolts & nuts,
washers, gaskets 3 mm thick, etc., with all complete Accessories 100 mm dia.
188 Supply, installation, testing & commissioning of Cast iron body Dual Plate Wafer Type 1.00 No 5820.34
NRV conf. to IS: 210, PN-1.6 complete with mating Flanges class # 150 with bolts & nuts,
washers, gaskets 3 mm thick, etc., with all complete Accessories 150 mm dia.
189 Supply, installation, testing & commissioning of SG iron body SinglePlate Wafer Type 1.00 No 1112.71
NRV conf. to ASTMA 536, PN-1.6 complete with mating Flanges class # 150 with bolts &
nuts, washers, gaskets 3 mm thick, etc., with all complete. Accessories 50 mm dia.
190 Supply, installation, testing & commissioning of SG iron body SinglePlate Wafer Type 1.00 No 1455.09
NRV conf. to ASTMA 536, PN-1.6 complete with mating Flanges class # 150 with bolts &
nuts, washers, gaskets 3 mm thick, etc., with all complete. Accessories 80 mm dia.
Item Rate In
Description of Item Quantity Unit Amount
No figures
191 Supply, installation, testing & commissioning of SG iron body SinglePlate Wafer Type 1.00 No 1797.46
NRV conf. to ASTMA 536, PN-1.6 complete with mating Flanges class # 150 with bolts &
nuts, washers, gaskets 3 mm thick, etc., with all complete. Accessories 100 mm dia.
192 Supply, installation, testing & commissioning of Y Type Strainer complete with mating 1.00 No 5563.55
flanges with bolts & nuts, washers, gaskets 3 mm thick, etc., with all complete
accessories. 80 mm dia.
193 Supply, installation, testing & commissioning of Y Type Strainer complete with mating 1.00 No 7275.42
flanges with bolts & nuts, washers, gaskets 3 mm thick, etc., with all complete
accessories. 100 mm dia.
194 Supply, installation, testing & commissioning of Y Type Strainer complete with mating 2.00 No 11555.09
flanges with bolts & nuts, washers, gaskets 3 mm thick, etc., with all complete
accessories. 150 mm dia.
195 Supply, installing, testing and commissioning of Normax make CI heavy duty ball type 1.00 No 4194.07
foot valve with flanges, nut bolts, gaskets etc. with necessary complete accessories.
196 Supply, installing, testing and commissioning of Normax make CI heavy duty ball type 1.00 No 6162.71
foot valve with flanges, nut bolts, gaskets etc. with necessary complete accessories.
197 Supply, installing, testing and commissioning of Normax make CI heavy duty ball type 1.00 No 12411.02
foot valve with flanges, nut bolts, gaskets etc. with necessary complete accessories.
198 Supply, installation, testing & commissioning of Four way fire brigade Inlet connection 1.00 No 8987.29
with 63 mm dia. stainless steel (SS304) instantaneous male inlets with built in non
return valve in each inlet with 150 mm dia. header pipe, suitable rubber cap and GI
chain including nuts, bolts, washers, gasket 3 mm thick, etc. with all complete.
199 Supply, installation, testing & commissioning of Two way fire brigade Inlet connection 1.00 No 5135.60
with 63 mm dia. stainless steel (SS304) instantaneous male inlets with built in non
return valve in each inlet with 100 mm dia. header pipe, suitable rubber cap and GI
chain including nuts, bolts, washers, gasket 3 mm thick, etc. with all complete.
200 Supplying FIRE bucket round bottom of 9 liters capacity made out of 24 gauge G.I Sheet 8.00 No 1027.12
with extra handle at bottom duly painted white inside and Red out side with FIRE mark.
Filled with dry-sand and kept on existing stand provided or hung on wall hook.
201 Supplying and erecting floor mounting Stand for keeping four nos. of FIRE buckets 2.00 No 5563.56
comprising 1500 mm in length, 900 mm height frame made out of 30mm x 30 mm x
mm angle iron with cross supports legs, welded with 4 hooks and duly painted with one
coat of primer and two coats of approved enamel P O red paint.
202 Supply & installation of stainless steel body Orifice Plate of suitable inner bore along 10.00 No 1069.91
with matching flange - as per specification & requirement as per hydraulic calculation.
Item Rate In
Description of Item Quantity Unit Amount
No figures
203 Providing and fixing approved make Perforated C type cable tray. Made from pre- 20.00 Mtr 471.67
galvanized sheet steel. The cable tray should be bended as per IS 2062/1079 . with max
17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of
engineer in charge..(5) 300 X 50 X 1.5 mm Thick
204 Providing and fixing approved make Perforated C type cable tray. Made from pre- 20.00 Mtr 322.19
galvanized sheet steel. The cable tray should be bended as per IS 2062/1079 . with max
17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of
engineer in charge..(3) 150 X 50 X 1.5 mm Thick
205 Supply, installation, testing & commissioning of Oblique pattern type stainless steel (SS 10.00 No 5435.17
304) single headed External Fire Hydrant Valve with 63 mm dia. female instantaneous
outlet conf. to IS: 5290, type - A, including mating flanges, galvanised nuts, galvanised
bolts/studs, washers & gaskets 3 mm thick with all complete.
206 Supply, installation, testing & commissioning of 63 mm dia. stainless steel (SS 304) 10.00 No 1754.66
Universal Branch Pipe conf. to IS:
207 Supply & installation, testing & commissioing of Fire Fighting Hose - conf. to IS : 636, 10.00 No 6967.29
type B (type- 3), The fire hose shall be 15 m long with 63 mm dia. stainless steel (SS 304)
couplings conf. to IS: 903, at both the ends for connection with the hydrant valve and the
branch pipe.
208 Supply, installation, testing & commissioning of fabricated from 3 mm MS sheet, hose 10.00 No 2525.00
box of size-450 mm x 600 mm x 250 mm - painted with Fire Red as per IS: 5, shade no.
536 front 3 mm thick transparent glass with lock & key, handle and brass hinges - to
accommodate one number of 15 mtr long hose and one number of universal branch
pipe, including supporting arrangement with civil work.
209 Supply, Installation, testing & commissioing of Swinging type mild steel hose reel drum 10.00 No 7403.82
with 20 mm dia. x 30 mtr. rubber hose as per IS: 884. The mounting stand shall be of
mild steel and the hose shall be fitted with a SS shut-off nozzle & SS ball valve of 25 mm
dia. including supporting arrangement with all complete. accessories
210 Supplying, fixing & testing of of CI ball Valve 25mm dia. (Thread) 22.00 No 706.14
211 Supplying, fixing & testing of New Battery of diesel engine 150 Amp. 1.00 No 15834.75
212 Supply and installation of Diesel Tank For Diesel Engine With All Accessories 100 Ltrs. 1.00 No 16690.67
213 Supplying, filling & testing lube oil for diesel engine 20.00 Ltrs 320.98
214 Supply and commissioning of Oil Filter. 1.00 No 706.14
215 Supplying, filling of diesel in diesel engine tank 75.00 Ltrs 89.87
216 Supply and commissioning of Diesel Filter 1.00 No 427.97
217 Supplying, filling & testing coolant to engine cooling for radiator 20.00 Ltrs 239.66
218 Filling Of Gaps Between pipe and Core Cutting Hole With Chemical and Cement 30.00 No 299.58
219 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to 25.00 Mtr 136.35
be erected as directed of following size. (E) 3 core 2.5 Sq. mm for pressure switch
Item Rate In
Description of Item Quantity Unit Amount
No figures
220 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper 25.00 Mtr 285.83
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench /
pipe at road crossing or floor of following size of cable. (Only Fire Panel to Fire Pump)
(B) 3 core 4 Sq. mm
221 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper 25.00 Mtr 497.93
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench /
pipe at road crossing or floor of following size of cable. (Only Fire Panel to Fire Pump)
(D) 3 core 10 Sq. mm (Only Fire Panel to Fire Pump)
222 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper 25.00 Mtr 213.11
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench /
pipe at road crossing or floor of following size of cable for Diesel Engine Battery
Charger (A) 3 core 2.5Sq. mm
223 Supply, Filling and Fixing of approved make ABC type fire extinguisher - 6 Kg. Capacity 10.00 No 1968.64
as per IS:15683 & IS :
224 Supply, Filling and Fixing of approved make CO2 type fire extinguisher. Capacity 4.5 10.00 No 5520.76
Kg. (conforming to IS-15683).
225 Supply, Filling and Fixing of approved make ABC Moduler type automatic fire 4.00 No 3423.73
extinguisher. Capacity 5 Kg. (conforming to IS-15683).
226 Submitting the application to obtain Fire Plan Approval and After Completion of Work 1.00 No 126250.00
Obtain Final Fire NOC for 3 Year.
227 Supply, Installation and commissioning of Air Release Valve, 25 mm Dia. connection. 2.00 No 1412.29
228 Supply, Installation and commissioning of Fire Alarm Panel Conventional type, 4 zone, 2.00 No 25250.00
with complete accessories.
229 Supply, Installation and commissioning of smoke detectors / heat detectors, with 60.00 No 1027.12
complete accessories.
230 Supply, Installation and commissioning of plug in base for the smoke detectors, hooters, 60.00 No 256.78
with complete accessories.
231 Supply, Installation and commissioning of Audio hooters , with complete accessories. 8.00 No 1069.91
232 Supply, Installation and commissioning of Manual Call Points, with complete 8.00 No 1010.00
accessories.
233 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper 1200.00 Mtr 176.75
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (A) 2 core 2.5 Sq. mm for Fire Alarm System
234 Core cutting in wall and in RCC slab with size as below: 50 mm dia. Hole 15.00 No 342.37
235 Core cutting in wall and in RCC slab with size as below: 80 mm dia. Hole 4.00 No 427.97
236 Core cutting in wall and in RCC slab with size as below: 100 mm dia. Hole 4.00 No 513.56
237 Core cutting in wall and in RCC slab with size as below: 150 mm dia. Hole 4.00 No 599.15
238 Core cutting in wall and in RCC slab with size as below: 200 mm dia. Hole 3.00 No 855.93
Item Rate In
Description of Item Quantity Unit Amount
No figures
239 Supply, installation, testing & commissioning of ISI approved electrical motor operated 1.00 Set 186850.00
Kirloskar make fire hydrant main pump set horizontal end suction back pull out top
discharge centrifugal fire pump set with all the standard acessories, base frame,
coupling, and foundation bolts with following specifications
Model -DB 80/26, Flow-97 m3/hr,
Head-70 meter,
Motor Rating -30KW/40HP/3 ph
Suc x Del - 80 x
240 Supplying, installing, testing and commissioning of Kirloskar make diesel engine driven 1.00 Set 378750.00
fire hydrant pump set, suitable for automatic operation and consisting of horizontal type
centrifugal end suction back pull-out, top discharge pump with cast iron body and
bronze impeller, mounted on M.S. fabricated common base plate with coupling, coupling
guard, foundation bolts and all necessary accessories, complete as required. The pump
shall be of Model KFE, having a discharge capacity of 97 m³/hr at 70 meters head, driven
by a diesel engine, 3 phase, with suction and delivery size of 100 mm x 80 mm.
241 Fire Hydrant Panel suitable for 10 HP Jockey Pump, 40 HP (97 m³/hr @ 70 m head) 1.00 No 106050.00
Main Electrical Pump and Suitable BHP (97 m³/hr @ 70 m head) Diesel Engine Operated
Pump, consisting of Incomer with MCCB (1 No.), R Y B Indication (1 Set) and VAF Digital
Meter (1 Set); Outgoing with F1 – 60 HP Star Delta Starter for Main Pump, F2 – 10 HP
DOL Starter for Jockey Pump, F3 – Auto On/Off Diesel Pump with Battery Charger,
Control Circuit with Auto/Manual On/Off, On/Off Trip Indication and On/Off Push
Button; Fabrication duly powder coated in PO Red Colour, fabricated from 14/16 SWG
GI Sheet with IP-42 Protection, fixed type floor mounted with bottom cable entry,
complete as required.
242 Pay Legal Fees to Concern Authority for Obtaining Plan Approval and Final NOC 5595.00 Sq.mt 15.15
243 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both 637.00 Pt. 582.77
are of ISI marked 1.1 kV grade FRLS PVC insulated multi strand copper wires up to
mtr length , in below type of pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on PVC / Metallic/Wooden
box, single mounting base frame covered with textured/metallic/white front plate
modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed. (f) with medium class Rigid PVC pipe
and accessories erected concealed in wall/ceiling complete Cat. III Add 1% labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
244 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of 447.00 Pt. 809.01
.ISI marked 1.1 kV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected with 6A Modular type switch and hum free EME
step type electronic fan regulator mounted and accessories with earth continuity of
following type erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules erected on / in wall / ceiling
as per pipe erected. with necessary ceiling rose / H.D.Connector as directed. (f) with
medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete Cat. III Add 1% labour cess
245 Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket 171.00 Pt. 309.06
erected on PVC / Metallic/Wooden box, single mounting base frame covered with
textured / metallic/white front plate modules erected on / in wall / ceiling with
following type accessories Cat. III Add 1% labour cess
246 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI 48.00 Pt. 612.06
marked 1.1 kV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length,
in below type of pipe erected complete with Modular type switch & 5 pin Plug erected
on PVC / Metallic/Wooden box covered with appropriate front plate modules erected
on / in wall / ceiling as per pipe erected with following type of accessories.[I] For 6A
Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db
board((f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling completeCat. III
247 [III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( green) 210.00 Pt. 1046.36
earthing wire from mcb d b board.(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling completeCat. III
248 Providing following type of Modular Type Accessories mounted with PVC / 48.00 Nos 160.59
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge. (3) Two Pin/RJ-11 Telephone Socket [A] For
One Gang Cat.III
249 Providing following type of Modular Type Accessories mounted with PVC / 378.00 Nos 160.59
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge. (8) Computer RJ-45 socket Cat.III Add 1%
labour cess
250 Providing and erecting Mains with 1.1 kV grade FRLS PVC insulated ISI marked stranded 3078.00 Mtr. 104.03
Copper conductor wire in following type of pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size (A) With medium class Rigid PVC
pipe and accessories (b) 2 wire 2.5 sq. mm Add 1% labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
251 Providing and erecting Mains with 1.1 kV grade FRLS PVC insulated ISI marked stranded 6804.00 Mtr. 140.39
Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with
2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for
earth continuity of following size (A) with medium class Rigid PVC pipe and accessories
(a) 2 wire 4 sq. mm
252 Providing and erecting Mains with 1.1 kV grade FRLS PVC insulated ISI marked stranded 120.00 Mtr. 184.83
Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with
2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for
earth continuity of following size (A) with medium class Rigid PVC pipe and accessories
(b) 2 wire 6 sq. mm
253 Providing and erecting Mains with 1.1 kV grade FRLS PVC insulated ISI marked stranded 840.00 Mtr. 326.23
Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with
2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for
earth continuity of following size (A) with medium class Rigid PVC pipe and accessories
(h) 4 wire 6 sq. mm Add 1% labour cess
254 Providing and erecting Mains with ISI marked, 1.5kV grade electrolyte multi stranded, 42.00 Mtr. 70.70
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required size of copper lugs,
nuts and bolts if required. (e) One wire 6.00 sq. mm
255 Providing and erecting Mains with ISI marked, 1.5kV grade electrolyte multi stranded, 111.00 Mtr. 115.14
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required size of copper lugs,
nuts and bolts if required. (f) One wire 10.00 sq. mm
256 Providing and erecting Mains with ISI marked, 1.5kV grade electrolyte multi stranded, 15.00 Mtr. 177.76
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required size of copper lugs,
nuts and bolts if required. (g) One wire 16.00 sq. mm
257 Providing and erecting Mains with ISI marked, 1.5kV grade electrolyte multi stranded, 6.00 Mtr. 295.93
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required size of copper lugs,
nuts and bolts if required. (h) One wire 25.00 sq. mm Add 1% labour cess
258 Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kV grade ISI 215.00 Mtr. 58.58
marked copper wires of following size to be erected as directed. (e) 1.50 Sq.mm 3 core
round PVC sheathed Add 1% labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
259 Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE 960.00 Mtr. 20.20
insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS
PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected
in existing pipe. of following size of conductors & nos.of pairs. With necessary
connections. [A] Conductor Size 0.5 mm (a) Unarmoured (2) Two Pairs Add 1% labour
260 Supplying & erecting approved make LAN cable of following size in existing pipe as per 7560.00 Mtr. 47.47
direction [C] CAT - 6 Add 1% labour cess
261 Providing & erecting Switch board for Computer or electric apparatus consisting of 378.00 Nos. 1133.22
following modular type accessories mounted with PVC/ Metallic concealed/ open box
with single mounting base frame covered with textured/ metallic/ white front
plate,modules erected with necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type Accessories
Cat. III Add 1% labour cess
262 Decorative call bell Ting-tong box type 250 volts complete erected Add 1% labour cess 24.00 Nos. 71.71
263 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt 568.00 Nos. 373.70
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V,
Power Factor more than 0.95, THD < 15%, CCT 3000 K to 6500K, Luminaire efficacy>
85 lumens/watt, LED LED driver efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates) (NOTE: Below description have shown ranges of Wattage capacity of LED
shown.) (A) Tube Light with integral driver (iv) 22-24 Watts, Surge - 2KV,IP-20,
conventional 4 feet Cat.III Add 1% labour cess
264 Supplying and erecting led lamps with following wattage capacity of 220 to 240 voltage, 33.00 Nos. 112.11
minimum 15000 burning hours life, 500 V in built-surge protection,Polycarbonate
diffuser, mounting suitable for E14 / E27 / B22 lamp holders, pf >= 0.5 (A) LED Lamps
integral type, with PC diffuser suitable LAMP holder (ii) 5 to 8 watts Cat-III Add 1%
labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
265 Supplying and erecting LED street light / Flood light fittings with High power White 43.00 Nos. 4248.06
LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than
130 lm/w and corrosion free High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio > 0.45, Luminaire efficacy > 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.The Engineer
(IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with
over-voltage protection. (ii) 48 - 59 WattsCat-III Add 1% labour cess
266 Providing and erecting Approved make Four pole moulded case circuit breaker having 3.00 Nos. 6790.23
breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to
100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 Hz. with
all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S.
housing ICS=100% of ICU only Cat III Add 1% labour cess
267 Providing and erecting Approved make Four pole moulded case circuit breaker having 5.00 Nos. 8861.74
breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A. with Fixed
thermal & magnetic release suitable to work on A.C.supply 50 Hz. with all internal
connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III Add 1% labour cess
268 Providing and erecting Approved make Four pole moulded case circuit breaker having 2.00 Nos. 17843.67
breaking capacity ICU of 35 KA. at 415 V. having Normal current rating 200A.with
variable Thermal & magnetic release suitable to work on A.C.supply 50 Hz. with all
internal connections, spreader tinned copper & complete erected in existing
G.M.S.housing ICS=100% of ICU only Cat III Add 1% labour cess
269 Providing and erecting Approved make Four pole moulded case circuit breaker having 2.00 Nos. 23041.13
breaking capacity ICU of 35 KA. and above at 415 V . having normal current rating
250A. with variable thermal & magnetic release suitable to work on A.C.supply 50 Hz.
with all internal connections, spreader tinned copper & complete erected in existing
G.M.S. housing. ICS=100% of ICU only Cat III Add 1% labour cess
270 Providing and erecting Approved make Earth fault Relay suitable to mount with inter 1.00 Nos. 5956.98
connection suitable to following size of moulded case circuit breaker having CT ratio &
MCCB rating as following along with shunt trip 220V AC. with all internal connections &
complete erected in existing M.S.housing.. (3) 250 A -400 A , CT Ratio 1/400 Add 1%
labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
271 Supplying & erecting approved make Four Pole 415V change over switch interior for 1.00 Nos. 13353.21
panel mounting with operating mechanism A.C.23 duty confirming to IS for (E)250A /
320A Cat-lll Add 1% labour cess
272 Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper 3.50 Rmt 3202.71
Busbars with four equal Nos. of electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating
tape for phase sequence of following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar, erected in existing cubical
panel with necessary connections. (B) Suitable for 200 Amp. capacity
273 Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper 2.00 Rmt 4909.61
Busbars with four equal Nos. of electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating
tape for phase sequence of following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar, erected in existing cubical
panel with necessary connections. (C) Suitable for 300 Amp. capacity Add 1% labour
274 Providing and erecting Miniature circuit breaker single pole 0.5A to 2A system and 39.00 Nos. 297.95
having breaking capacity 10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat-III Add 1% labour cess
275 Providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to 312.00 Nos. 123.22
operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark Cat-III Add 1% labour cess
276 Providing & erecting 240 V MCB double pole switch for motor & inductive load (C 20.00 Nos. 362.59
Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having
following capacity (B) 40 Amp. Cat-III Add 1% labour cess
277 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 8.00 Nos. 736.29
10KA breaking capacity & confirms to IS :8828 in existing box having following capacity
(b)40 Amp. Cat-III
278 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 50.00 Nos. 811.03
10KA breaking capacity & confirms to IS :8828 in existing box having following capacity
(c)63 Amp. Cat-III Add 1% labour cess
279 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / 6.00 Nos. 1152.41
surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used) suitable for (A) single phase
incoming and horizontal single phase outgoing (b) sheet steel double door (IP-43) (iii)8
Item Rate In
Description of Item Quantity Unit Amount
No figures
280 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / 24.00 Nos. 2339.16
surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used) suitable for (B) three phase
incoming and single phase horizontal type outgoing Per phase isolation type (PPI) (b)
sheet steel double door (i)4 way Add 1% labour cess
281 providing and erecting Approved make RCCBs conforming to IS: 12640 and having 78.00 Nos. 2458.34
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz. having characteristic of quick action & tripping
with all advance feature & do not incorporate any electronic component. for following
Max. rating erected as directed (ii) 40Amps. DP Cat. III Add 1% labour cess
282 Providing and erecting Annealed bare Copper wire 4.064mm to 1.626mm .Add 1% 70.00 Kg. 794.87
labour cess]
283 Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. dia. 19.00 Nos. 368.65
galvanised iron pipe with coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.Add 1% labour cess]
284 For using salt and charcoal / coke as required for pipe type earthing.Add 1% labour 19.00 Nos. 171.70
285 Supplying & erecting earth pit of minimum bore dia.150mm size approved make 6.00 Nos. 4591.46
Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of
corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover. (A)(approved make OEM has to
submit test certificate including value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to ensure the value of earthing resistane
mentioned in test Certificate) & having back filling compound of (B) Inner chemical
(CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage
drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :-
Earthing compound should be capable to retain moisture for long time Necessary test
report must be submitted by Agency. (a) For Electrical Installation up to 440V in
normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg .Add 1% labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
286 Providing & erecting weather proof, dust & vermin proof, floor mounted front operated 7.50 SqMtr 10468.65
indoor type cubical panel board necessary IP-42 and above protection as per approval
from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors,
16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories
supporting angles/ flats channel including cutting, bending, drilling, welding, riveting
with internal partitions & cable alley as per requirements & instruction of engineer-in-
charge with erection of supplied switch gears, BUSBARS, suitable size of inter
connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite
control fuses/MCB for measuring instruments, earth bus & earth bolts, foundation
flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking
arrangement and rubber gasket,heavy duty end terminal connection,danger notice
board,necessary ventilation,earthing strip complete. The Panel shall be painted with
epoxy powder coating. (The rates excludes the cost of switchgears, bus bars, inter
connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be
measured excluding base beams) The panel shall be supplied with following approved
manufacturers with following size. (A) locally fabricated panel board (i) with 350 mm
depth Add 1% labour cess
287 Providing , erecting , fabricating the M.S. structure as per requirement on site 48.00 Kg. 77.77
incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections
complete with cutting, welding, grinding & finishing duly painted with one coat of red
oxide with erection on site as per direction of engineer in charge with necessary
grouting, cementing, plastering & finishing complete. Add 1% labour cess
288 Providing and erecting FRLS-XLPE(IS:7098)(I)-88 ISI armoured cable Aluminium 50.00 Mtr. 112.11
conductor for 1.1 kV. to be laid on wall with necessary clamps or in existing trench /
pipe of following size of cables. (B) 2 core 6 Sq. mm Add 1% labour cess
289 Providing and erecting FRLS-XLPE(IS:7098)(I)-88 ISI armoured cable multistrand 80.00 Mtr. 341.38
Aluminium conductor for 1.1 kV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm
290 Providing and erecting FRLS-XLPE(IS:7098)(I)-88 ISI armoured cable multistrand 30.00 Mtr. 454.50
Aluminium conductor for 1.1 kV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2
291 Providing and erecting FRLS-XLPE(IS:7098)(I)-88 ISI armoured cable multistrand 182.00 Mtr. 876.68
Aluminium conductor for 1.1 kV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2
292 Providing and erecting FRLS-XLPE(IS:7098)(I)-88 ISI armoured cable multistrand 120.00 Mtr. 1085.75
Aluminium conductor for 1.1 kV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2
core) Add 1% labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
293 Providing and erecting FRLS-XLPE (IS:7098) (I)-88 ISI armoured cable multistrand 975.00 Mtr. 151.50
/Solid Aluminium conductor for 1.1 kV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (B) 4 core 6 Sq. mm
294 Providing and erecting FRLS-XLPE (IS:7098) (I)-88 ISI armoured cable multistrand 130.00 Mtr. 168.67
/Solid Aluminium conductor for 1.1 kV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (C) 4 core 10 Sq. mm Add 1% labour
295 Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the 1239.00 Mtr. 55.55
fault all over the run and back filling the same and making the surface as normal
ground. Add 1% labour cess
296 Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth 50.00 Mtr. 74.74
for laying any size of cable or locating the fault all over the run and back filling the same
and making the surface as normal ground.
297 (B) If additional machinery like hammer driller or JCB use [Add]Add 1% labour cess 40.00 Mtr. 357.54
298 Providing & laying approved make Double walled corrugated pipes (DWC) of 1419.00 Mtr. 62.62
polyethylene (conforming to IS 14930 II) with necessary connecting accessories of
same material at required depth in existing trench for laying of cable. below ground /
road surface for enclosing cable (A)50 mm outer dia Add 1% labour cess
299 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC 78.00 Nos. 38.38
insulated armoured cable complete with out going tails, insulating tape etc for following
size of cables. (B) 2 to 4 core 6 Sq. mm Add 1% labour cess
300 Providing and, fixing heavy duty flange type brass double compression type cable 4.00 Nos. 103.02
gland with rubber ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (C) 3 & 1/2 core 70 Sq. mm
301 Providing and, fixing heavy duty flange type brass double compression type cable 2.00 Nos. 190.89
gland with rubber ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (F) 3 & 1/2 core 150 Sq. mm
302 Providing and, fixing heavy duty flange type brass double compression type cable 2.00 Nos. 238.36
gland with rubber ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (G) 3 & 1/2 core 185 Sq. mm Add 1%
labour cess
303 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of 312.00 Nos. 6.06
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/ cadmium plated nut bolts in an approved manner. (A) 1.5/
304 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of 16.00 Nos. 25.25
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/ cadmium plated nut bolts in an approved manner. (E) 70 Sq.mm.
305 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of 8.00 Nos. 61.61
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/ cadmium plated nut bolts in an approved manner. (H)
Item Rate In
Description of Item Quantity Unit Amount
No figures
306 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of 8.00 Nos. 80.80
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/ cadmium plated nut bolts in an approved manner. ( I )
Sq.mm. Add 1% labour cess
307 Supply, Installation, Testing and Commissioning of suitable sweep, BEE 5 Star rated, 447.00 Nos. 2629.03
Ceiling fan with Brush Less Direct Current (BLDC) permanent ferrite magnet Motor,
class of insulation: B, Rust free 3 nos.Aluminium blades, 2 nos. canopies, shackle kit with
earthing provision, copper winding, Power factor not < 0.9, Service Value (CMM/W)
minimum 6.85, Air delivery minimum 215 CMM, 350 RPM,230v (tolerance as per IS :
374-2019), THD < 10%, compitible with electronic regulator unit for Speed Control and
all remaining accessories including safety pin, nut bolts, washers, temperature rise =
°C (Max.), suitable for 140 to 285 Voltage and rectifier circuit with surge, over current
and overload protection , 50 Hz, Single phase AC Supply, earthing etc. Complete as
required.[ Make shall be approved by Engineer in Charge] (A) 1200 mm Sweep (48")
Add 1% labour cess
308 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod 447.00 Mtr. 108.07
erected duly painted for fan complete with proper insulation without leakage and
earthing. Add 1% labour cess
309 Supplying & erecting Fan Hook of 10 mm M.S. Round bar grouted in RCC slab with 447.00 Nos. 43.43
Making the site as original.Add 1% labour cess
310 Supplying & erecting single phase approved make industrial exhaust fan suitable for 12.00 Nos. 2054.34
medium duty ring mounted low noise operation suitable for medium duty having
following dia size and maximum speed in RPM [A] 300-305 mm dia 900 RPM Cat.II Add
1% labour cess
311 Supplying and erecting approved make Octagonal pole made from HR sheet steel. The 31.00 Nos. 7561.87
pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with integral Junction box consist
of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for
MCB Mounting, stud type terminal and arrangement for cable termination to be erected
With Suitable foundation (Included) as per details given by manufacturer considering
site requirement. (C) 5 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm thickness
with 200mmX200mmX12mm base plate, 4-M16 Bolts and 600mm long with necessary
G.I. J Bolts .Approx Pole weight 46 kg Add 1% labour cess
312 Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop- 8.00 Nos. 476.72
out approx. 2mm thick box complete with Bakelite connector strip 5way (3P+N+E), DIN
rail for mounting mob & hinged doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable
clamps& earth bolt of following size of box. (C)150mm x 125mm x 100mm [deep] Add
1% labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
313 Supplying and erecting Street light pole bracket comprising main B Class GI pipe of 4.2 27.00 Nos. 491.87
cm/require outside dia. complete with suitable B Class G.I. sleeve tubing of approx.
45cms.length and suitable for 76.5mm/80mm/require size of pole top having nuts and
bolts for fixing the brackets and having spread of 0.5 mtr. Length with 110 deg.with
vertical plane and suitable welded stiffener reducer and nipple with check nut complete
painted with one coat.of Red oxide / PU base primer and two coats of Aluminium / PU
paint. paint with following nos of arms. [A] Single Arm bracket 0.5 Mtr
314 Supplying and erecting Street light pole bracket comprising main B Class GI pipe of 4.2 4.00 Nos. 622.16
cm/require outside dia. complete with suitable B Class G.I. sleeve tubing of approx.
45cms.length and suitable for 76.5mm/80mm/require size of pole top having nuts and
bolts for fixing the brackets and having spread of 0.5 mtr. Length with 110 deg.with
vertical plane and suitable welded stiffener reducer and nipple with check nut complete
painted with one coat.of Red oxide / PU base primer and two coats of Aluminium / PU
paint. paint with following nos of arms. [B] Double Arm Bracket 0.5 Mtr Add 1% labour
315 Supplying and erecting B class galvanised iron pipe 32 mm outside dia 45 cm long duly 8.00 Nos. 343.40
welded on 20 cm x 20 cm x 3 mm thick M.S. base plate, erected on wall or corner for
mounting street light luminaire with necessary hardware materials duly painted.Add
1% labour cess
316 Supplying & erecting IP 55 grade following size section pillar fabricated from joint less 3.00 Nos. 3595.60
M.S. Sheet with angle iron legs made from jointless M.S. Angle with cable clamps to be
buried in ground to have appropriate erection to work uniform until erected with
cement concrete foundation and 45 cm high bricks work finishing with plaster etc.
hinged double door internally supported on both side, with internal and outside
looking arrangement with look and keys in duplicate 35 x 35 x 5 mm M.S. Angle of Two
Nos. one is welded and other with nut and bolt for erecting Bakelite sheet. Painting the
Section Pillar inside and out side with three tank powder coated paint. section pillar
roof should be without joint with water leakage proof & tested as per IP 55 test &
followed by IS 2147 of 1962 (B) 75 X 60 X 45 cm section pillar fabricated from 16 Gauge
MS Sheet with angle iron legs 45 cm long made from 35 X 35 X 5 mm thick MS angle.Add
1% labour cess
317 Supplying & erecting approved make Digital time switch having lithium cell 6 years 3.00 Nos. 3168.37
operative and operate battery backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup
time 1 minimum & LCD display. Also comprised permanent ON/OFF switching.
Programming switches & housed in fire proof thermoplastic enclosure & transparent
cover erected as required with necessary connection erected as directed.Add 1% labour
318 Supplying & erecting power contactor, AC3 duty for time switch complete erected as per 3.00 Nos. 2782.55
direction Cat III (D) 4 pole 440V 40 Amp. Add 1% labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
319 Providing & erecting, programming, testing of chairman unit microphone with flexible 1.00 Nos. 7191.20
stem of 480 mm in length and light ring built in loud speaker ,two head phone socket
,attractive design ,priority button for chairman microphone,built in volume control for
head phones,chime tone facility to precede chairman priority calls,microphone on/off
button,red indicates for microphone is active,frequency response -400Hz to
10kHz,nominal acoustic input -85 dB SPL [[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ] Add 1% labour cess
320 Providing & erecting, programming, testing of Delegate unit microphone with flexible 16.00 Nos. 6678.12
stem of 480 mm in length and light ring built in loud speaker ,two head phone socket
,attractive design ,built in volume control for head phones,chime tone facility to precede
chairman priority calls,microphone on/off button,red indicates for microphone is
active,frequency response -400Hz to 10kHz,nominal acoustic input -85 dB SPL
[[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Add
1% labour cess
321 Supplying & erecting Amplifier having following specification: 1.00 Nos. 13558.24
Power Output :250W (RMS) (300W Max.)
inputs : 6 Misc. & 2 Aux.
frequency Response :50-1500HZ I3db
Tone Controls :Cut & Boost type
LED Meter :5 LED Arrays
The amplifier suitable to operate 240V A.C.& 24volt D.C. (Battery) with automatic
changeover from AC to Battery operation, duly protected by wrong Battery Polarity
connections. [[Approved by Competent Authority i.e. not Below the rank of Executive
Engineer ] Add 1% labour cess
322 Supplying and erecting wall mount speaker with rated power of 30 watt/power tapping 6.00 Nos. 3083.53
30/15/7.5 watt available,opening angle 180 degree H * 77 degree V ,sound pressure
level 88 dB ,frequency response of 70Hz to 20KHz [[Approved by Competent Authority
i.e. not Below the rank of Executive Engineer ] Add 1% labour cess
323 Providing and erecting cordless microphone with UHF Diversity handheld wireless 1.00 Nos. 6163.02
microphone/caller wireless complete with receiver and transmitter unit,Cardiod ,polar
pattern,dynamic microphone,LCD display for battery and frequency status and
information ,32 preset channels,with compatible groups of 8 channels,14 hrs.battery
life,frequency response 80Hz to 18KHz.,RF sensitivity <1.0 Uv,image rejection >
dB,dynamic range >95 dB and receiver having 32 channels,S/N ratio>100 dBA,Dynamic
range>95 dB,distortion<1% [[Approved by Competent Authority i.e. not Below the rank
of Executive Engineer ] Add 1% labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
324 SITC of 3LCD Lamp based projector having wxga (1280x800) or better resolution with 1.00 Nos. 33895.60
minimum white brightness of 3800 lumens and color brightness of 3800 lumens. The
projector should have minimum 1HDMI,1VGA input. Having contrast ratio of 15000:1 or
more. the projector should have auto vertical key stone correction of +/- 30 degree and
Manual Horizontal of +/-30 degree. the projector should have optical lens, throw ratio
1.30-1.56:1. Zoom Factor of 1.2. Lens focus Manual having focal length 16.9mm to
20.28mm. projector should have features like AV mute slide, quick corner and split
function and should support wireless functionality with inbuilt wifi or wifi dongle.
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Add
1% labour cess
325 SITC of 100 inch Self Lock MW (7 x 5) Instalock Slow Retraction Screen, Aspect Ratio-4:3 1.00 Nos. 3810.73
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Add
1% labour cess
326 Providing and erecting Inverter based approved make split air-conditioning unit 8.00 Nos. 56833.71
consisting of condensing unit with variable speed fan motor, inverter type hermetically
sealed rotary compressor with accessories etc. duly connected separately erected
evaporating unit and blower motor with its accessories by means of extra supplied
proper insulated copper tubing,drain PVC pipes suitable for ( cost includes Eco Friendly
green gas charging and 15A plug top & Remote Control & MS Stand) with necessary core
cutting. (1)For ISEER Range (KWH/KWH)(3.1 to 3.99) (C) for 1.7 to 2 ton capacity Add
1% labour cess
327 Supplying and erecting insulated pair of soft copper tubing open or concealed including 80.00 Rmt 1158.47
power and control cable,necessary PVC drain pipes for Split/Cassette AC machine up to
4 TR capacity
328 Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity 3.00 Nos. 61482.74
150 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should drop
by 15˚C within a hour, The water cooler should be comprising of hermetically sealed
compressor, fan motor, condensing unit, water tank surrounded by evaporating, coil,
thermostats, relay etc.complete with necessary inlet & outlet connection. The body of
water cooler will be made from Stainless Steel and ISI Certified. Add 1% labour cess
329 Supplying & erecting 5 stage single reverse osmosis water purification system with M.S. 3.00 Nos. 29187.99
powder coated frame, prefilter housing with 'O' ring presediment filter GAC filter,
carbon filter suitable buster DC pump capacity 80 psi, mention with 40 psi inline type
post carbon filter auto low & high pressure switches with following size of storage tank
& LPH capacity & erected as directed [C] 50 Ltr / Hr with 150 psi 2 nos booster pump
Add 1% labour cess
330 Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 4.00 Nos. 1275.63
digits LED display, 0 to 750 AC Volts range erected on existing panel board with all
connection, wiring etc .with manufacturers calibration certificate. Add 1% labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
331 Supplying and erecting approved make panel mounting type Digital Ammeter having 3 4.00 Nos. 1558.43
digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to
operate on 500 Volt AC, erected on existing panel board with all connection, wiring etc
.with manufacturers calibration certificate. Add 1% labour cess
V on existing panel board with necessary connections. Add 1% labour cess
333 Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 12.00 Nos. 274.72
15 VA burden erected in existing CRCA box duly secured with insulating materials
connected to the meter Add 1% labour cess
334 Supplying and erecting approved make suitable panel indicator LED type lamp, lens 12.00 Nos. 43.43
cover, complete erected with necessary connections. Add 1% labour cess
335 SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm 4.00 Nos. 9416.23
long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse
current withstand test: 100 kA of 10/350µs waveform in an accredited Third party
laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST 34mm dia
mm long- Cold Galvanized Add 1% labour cess
336 SITC of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per 180.00 Mtr 299.97
IEC 62561- 2 conducted in the Govt. accredited thirty party laboratory to meet the
requirement of IS/IEC 62305 with Required Accessories - Aluminium Holding clamp at
every 1 mtr distance, Aluminium/SS cross splicer at every crossing of Alu. conductor,
Expansion piece with connectors at every 20 mtr distance, Aluminium straight Splicer to
connect conductors. All Accessories should be tested as per IEC 62561-1 2018 Cl. 6.3 for
conditioning & Ageing Test & 6.4 for Lightning impulse current withstand test: 100 kA
of 10/350µs waveform(Ageing & Electrical test ) conducted in a sequence manner &
tested in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC
6230 Add 1% labour cess
337 SITC of Galvanized Steel Flat 25x6 mm thickness from earth electrode directly in 80.00 Mtr 154.53
ground as required. Zinc coating: 500 g/m square (Approx:70 micron coating) tested
and used exclusively for lightning protection earthing system and ring equipotential
bonding. Add 1% labour cess
338 SITC of 14.2 mm dia 3 mtr long Earth electrode of High tensile steel electrode with 250 4.00 Per Set 5992.33
micron copper bonding & 1 bag of Carbon fill Based environment friendly backfill tested
as per IEC 62561-7 in NABL accredited Laboratory and suitable stainless Steel double
sided clamp. Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit
Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm
(height). Add 1% labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
339 Supplying, Erecting, Testing & Commissioning the MRL passenger lift having following 1.00 Nos 2004187.44
main features: [1] GEAR LESS LIFT DRIVE (MRL) comprising of High Starting torque Lift
3 phase 440 V A. C. Permanent Magnet Synchronous motor of proper rating with high
efficiency shall be used.[2] Micro processor based / PLC, ACVVVF, vector control drive
with encoder feedback closed loop system shall be used for lift car and door operation
hall stops, Main, Up/ Down Contactor with overload and phase reversal relay and safety
[3] Car with M S platform with bracings of adequate size and to sustain the impact load
cabin + passenger with safety factor of fire for steel and side panels of Stainless steel of
sheet of grade 304 duty. Car ceiling will be S.S. finishes with aesthetic appearance with
LED ceiling lights. Car flooring shall be of s/s 304 chaker plate design suggested of
engineer in charge. of engineer in charge. Car doors shall be of stainless steel grade
hairline finish with centre opening / telescopic automatic doors. Car panel will also be
S.S. 304 finished with emergency stop device, mechanical door safety device, facility of
auto/ attended mode. All car panel buttons and all floor switches must be with brail
language as per lift act. [4] All landing doors must be fire rated for 2 hour shall be fully
automatic centre opening/ telescopic opening made of hairline finish steel grade of
with key holes and infrared curtains with Unlocking facility from outside [5]
Appropriate battery operated emergency light in the car along with alarm switch shall
be provided. Also, Emergency Light & Fan should start immediately without any Time
Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow along with floor position
indicator shall be provided inside the car and at all floors.
[7] Full height infra red curtain with multiple cross / crossing light beams shall be
provided. [8] Automatic Rescue Device (ARD) shall be provided accordingly of
passenger capacity with Manual Rescue Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over loading shall be provided such
that doors kept open till excess load is removed.
Item Rate In
Description of Item Quantity Unit Amount
No figures
[[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music shall be provided in lift car.
[13] Self diagnostics system for operational and safety parameters shall be provided in
control panel.
[14] Mechanical over speed governor with governor calibration as per actual site
parameters and submission of calibration certificate submission, door key holes in the
floor doors, fireman switch shall be provided. [15] Lift machine hoisting arrangement in
the lift machine room and monkey ladder for lift pit should be provided by the lift
agency, along with the other steel structure works, foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without any extra cost, where ever
required as / if directed by engineer in charge.[17] Permanent wiring with necessary
safety devices like RCCB in all circuit, Over Voltage Under Voltage protection and THD
eliminator in circuit for lift machine room and lift well with proper numbers of light
points, with fixtures, exhaust fan and plug points shall be provided by the agency. Only
phase Power Supply shall be made available by department in lift machine room.
Necessary Earthing as per Lift Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and alteration in lift shaft and machine
room related to erection of lift shall be made by lift agency without any extra cost.
(granite/marble fixing around all landing door openings are not in lift agency’s scope.)
[19] Agency has to provide all working drawings and documents and liaison services for
obtaining all necessary permission from lift inspector and other authorities.
[20] acrylic transparent licence/ display A4 size holder in lift car [20A] As per statutory
requirement of Govt. Of Gujarat lift & escalator act 2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor. 4.carrying out third party lift inspection
during/after lift erection and provide report by third party authorized by concern
licensing authority 5.agency has to provide third party insurance upto completion of
free maintenance period and submit the document for the same.
Item Rate In
Description of Item Quantity Unit Amount
No figures
[21] Car Panel Operating Buttons with floor position indicator/buttons must be of Auto
Glow type clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full Length Handrails of hairline finish steel
grade of 304 should be provided at appropriate height on the Rear & Side Wall Panels
in Lift Car.
[23] With Necessary KVA rating voltage controlled Stabilizer suitable for your
controller, drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required for lift is in scope of work which
rating is sugested by CEICED Department (electrical Inspector) (B) SPECIAL FEATURES
DESCRIPTION OF LIFTS for PREMIUM category 1. Advanced control system dual 64 bit
embedded microprocessor with CANBUS Serial Communication mode including
Regenerative power efficient operation,on site programming facility, Anti nuisance, Pte-
opening, BMS/RMS with necessary online real time monitoring system having necessary
connectivity for remote monitoring & other suitable supporting hardware & software
devices to fulfil the purpose.
2. Floor Indication LCD Display with call registration & brail mark with arrival gong and
hall lantern & TFT Screen in the car with MP3 Voice Announcer. 3. CAR Panel should be
Scratch resistive SS Moonrock finish / Hair Line / Honeycomb for car and all Doors, All
landing doors must have fire rating up to 2 hours and car door must have multi-level
crisscross beam door protection. 4. To & fro communication system & wiring (i.e. car,
control room & guard room) and Each elevator are equipped with remote monitoring
system. agency has to provide mobile app and user id and password for monitoring
passengers . Ground plus 2 upper floors with Rated Speed of 1 m/sec with micro
price/PLC control and ACVVVF. drive (C) With General PLUS ADDITIONAL SPECIAL
FEATURES attached herewith. Prem. Cat.Add 1% labour cess
340 Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar Power 20.00 PER KW 42455.35
Plant with
Solar Panels (ALMM approved): Frame Material : Anodized Aluminum alloy Frame With
Twin Wall Profile, Front Cover : High Transmission Low-Iron Tempered Glass (AR
Coated), High efficency and positive power tolerance Pmax: 0/+5, Module Efficiency
should be approx. 19.5%-22%, Normal operating temperature 45'C, Junction Box with
Waterproof IP67 & MC4 Compatible and Enclosed with Bypass diodes, 100%
Electroluminescence test to ensure error free Modules, Thep. temp. co-efficient of the
PV module shall equal or better than -0.45%/degree C. Solar PV modules of minimum
fill factor 75% to be used. Unit Production:- More than 4.5 Unit /kw /day (Actual)(1Year
Avg) With 10 year Product warranty. Modules must be complied to the DCR(Domestic
content requirements). The Ration of AC to DC is 5:6 for the Installation capacity which
are given in AC KW.
Item Rate In
Description of Item Quantity Unit Amount
No figures
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max efficiency: 97.5% - 98.9%,
O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P
THDi: <3%, Operating Tempreture Range: -25~60°C, Integrated protection of Inverter
are Anti-islanding Protection, Input Reverse Polarity Protection, Insulation Resistor
Detection, Ground fault protection, Residual Current Monitoring Unit, Output Over
Current Protection, Output Short Circuit Protection, Output Over Voltage Protection, PV
array string fault Protection. Protection Degree: IP65, User Interface LCD & APP,
Datalogger & Communication: GPRS / Wi-Fi.
Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor Detection
Integrated, Residual Current Monitoring Unit Integrated, Output Over Current
Protection Integrated, Output Short Circuit Protection Integrated, Output Over Voltage
Protection Integrated, Protection Degree: IP65, User Interface LCD & APP,Datalogger &
Communication: GPRS / Wi-Fi, Module Mounting Structure: The mounting (Rectangular
pipe / square pipe / circular pipe) with requisite cross bars, nuts and bolts, etc. shall be
Hot deep galvanized with minimum 80micron coating. The Rectangular / square
/circular hollow pipe section used for the structure should have a minimum thickness of
2.0 mm. other than above, the material thickness should be minimum 2.5 mm. A
certificate of a structural engineer certifying the strength and stability of the mounting
structure to withstand the weight and wind speed of 150 km/hour , shall be submitted
by the vendors. Hot Dipped Galvanized steel coils. suitable arrangement for base plate
for foundation
solar panel mounting, the structure should be suitable for carry the load of solar
panel,wiring, sprinkler system etc. with necessary foundation work/wall mount, j bolt,
anchor fastner etc. the nut bolt used for installtion of stucture should be (SS 304)
quality.The ground clearance of the bottom most edge of solar panel shall not be less
than 300 mm to 1200 mm or as per site’s technical/feasibility requirement.
a. Column –The minimum section (thickness) should be 60MM*40MM
b. Rafter - The minimum section (thickness) should be 60MM*40MM
c. Purlin - The minimum section (thickness) should be 40MM * 40MM Balane of System
with necessary Swichgears (Suitabel size and protection of ACDB & DCDB), inter
connecting wiring, earthing system as per the CEIG drawing approval,
lightining arrester system as per the CEIG drawing approval, all liasoning work with
various gov. dipartment like state nodal agency,DISCOM & CEIG is included in agency
scope (Excluding All charges namely GEDA Application fees, Solar connectivity
Charges, Meter connectivity Charges, Meter testing Charges and system
stability/strenthning charges.) (Excluding All charges namely GEDA Application fees,
Solar connectivity Charges, Meter connectivity Charges, Meter testing Charges and
system stability/strenthning charges.) (C ) Grid Tied Solar Power System: 11 - 25 kW (3
- phase) Add 1% labour cess
Item Rate In
Description of Item Quantity Unit Amount
No figures
341 Providing & erecting Automatic solar panel cleaning system for solar power projects 20.00 PER KW 1841.23
which includes necessary plumbing work (UPVC pipes and accessories) from source of
water to project site (up to 30 meters),Suitable size of sub mercible/ open well motor,
necessary wiring for motor and sprinkler system with safety, timer circuit for
automatically on/off the sprinkler system, necessary size oand number of nozzles/JET
(minimum 1 Nozzle/Jet per module).(D) 21KW-50KW Cleaning System Add 1% labour
Total Rs.
Rs.Fifteen crore twenty five lakh twenty four thousand one hundred twelve rupees and sixty one paisa only
I/We am/are willing to carry out the work at………………….% above/below percent(Should be written in figures and words) of the estimated rate mentioned
above. Amount of my /our
Tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
In words In words
The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which no extra payment
1 shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 Income tax TDS will be deducted at a source while making payments of bills
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement Consumption/16/C
Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the cost of difference of cement
4 consumption have been deducted from the rate of original item at the rate of input rate mentioned in all the tender.
Executive Engineer
Tapi ( R & B ) Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NEW SBD-TALUKA SEVASADAN VALOD.pdf
BOQ-taluka sevasadan valod.pdf
PQ - taluka seva sadan valod.pdf
SPECIFICATION-taluka seva sadan valod.pdf
4 Building-Specification Booklet 2 side.pdf
GR.pdf
GR Clouse 24 iv 34 52.pdf
GRPQ.pdf
drawing.pdf
Elec- Approved make list 2013 2014 Part 1 (1).pdf
Elec-Approved make list 2013 2014 Part 2 (1).pdf
Elec-critaria GR.pdf
Elec-Memorandum of Understanding.pdf
Elec-NOMINATED ELECTRICAL SUB CONTRACTORS.pdf
Elec-SOLAR CONDITION.pdf
Elec-SPECIAL CONDITIONS.pdf
Elec-Techanical specification.pdf
extraGR.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .