Loading…
Loading…
Tender Value
₹6.5 Cr
EMD Value
₹13.1 L
Closing Date
22 Jun 2026, 12:30 pmClosed
Provision of MSDAC in parallel to DC track circuit at newly commissioned ANH & NBG station of DDU Division.
SG-DSE-OT-12-26~ECR
SG-DSE-OT-12-26
Open
Works - General
12 Months
Chandauli, Uttar Pradesh
₹0
₹13.1 L
22 Jun 2026
29 May 2026
8 Jun 2026
1-Provision of MSDAC in parallel to DC track circuit at newly
"Supply, Design, Installation, Testing and Commissioning of Multi Section Digital Axle Counter (MSDAC) complete system as per RDSO Specification No. RDSO/SPN/176/2013 version.3 with latest amendments STR No. SIQ 0001 Ver.2.0 or latest. MSDAC Reset procedure shall be as per ECR MSDAC Reset policy. Tenderer shall design the scheme for provision of required number of evaluators, reset equipment's, trackside junction boxes, detection points and track clearance relays 1 etc and shall be submitted along with the offer. Remote Diagnostic System shall be provided at station. Length of the cable required for each DP and Rail Type will be specified at the time of issuing call Letter. This also includes supply of 10% all types of spare cards, LV Boxes, Wheel sensors and other essential modules as specified in RDSO Spec, it shall be rounded to nearest integer subjected minimum of one item. One set of Specialized Tool and Measuring equipment's as per RDSO specifications shall be supplied per location (Station/ALH/OC/IBH). (Per DP is Per Detection Point). Note: It also includes supply and Installation of any earthing arrangement, if required as per OEM specification. Inspection: RDSO - for supply items." 1650000.0
Alteration & Modification in existing EI for integration of MSDAC . Annexure-D
Laying of Optical Fibre cable/Quad through HDPE /Telecom duct for OFC by blowing asper detail in technical suppliment / latest railway guidelines and advised by site engineer.
Unwinding of S&T cable using jack & tindle, pulleys laying of cable in normal cable trench & pipe without any physical damage & twist up to & inside the location box / cabin.
"Excavation of trench in all kinds of soil and refilling of trenches (1 Mtr. Depth 300 mm width)- iii)\Without bricks - Note:- (I) Payment will be made as per actual work done on pro rata basis, if required depth is not available at site. (II) If the depth of trench is not uniform in a span of 100 mtr.or shorter length, if site condition demands along the cable run minimum depth will be taken for that particular stretch for payment."
Back filling of trench by shifted earth after laying the cable and ramming the earth upto original ground level.
Excavation, trenching, earth work and reinstatement of track while track crossing.
Reinstatement of platform and repairing to original state after cable laying work.
Repair of PUCCA Roads to original state in level xing area after cable laying works.
Installation of Double Wall Corrugated (DWC) pipe with socket coupler. This includes trenching (1.2 mtr. Depth) and back filling.
Supply of split DWC pipe with the socket / couplar and T Joint where ever required, size of outer dia 300 mm / inner dia 260 mm. Inspection- RITES
Installation of Split DWC pipe
Concreeting on Railway cables/S&T gears with 1:2:4 massonary work. All materials required for execution of the work will be supplied by firm.
Supply and Installation of basic material to construct unit maintenance free earth as per RDSO Spc.No.RDSO/SPN/197/ 2008 or latest, (Inspection: RITES)
Supply of quarter size apparatus case as per design of GKP signal workshop. Inspection - Consignee
Casting, Concreting and Curing of foundation for Quarter Size apparatus case(GKP- type) including cost of all materials required for fixing holding down bolts, casting concreting and fixing of "E" type lock.
Supply of full size location box as per design of GKP signal workshop Inspection - RITES
Supply of E-type lock without key, spec. no. IRS-S-30, Drg.no.S-3376/M key -S-3377/M or latest. Individual number of miniature E locks and Normal size of locks required at site to be decided by the site engineer as per site requirement. Inspection - RDSO.
Supply of Key for E type lock supplied above Inspection :RDSO.
"Casting, Concreting and Curing of foundation and erection for Full apparatus case(GKP- type) as per DRG No. SGW/MGS/L1/91 including cost of all materials required for fixing holding down bolts, casting concreting and fixing of E type lock. "
Fixing, wiring of terminal strips, bakelite strip, transformers, relays fuses with base 22 and supply and fixing of shelves for full apparatus case with termination earthing of cable and wiring with lettering as required including supply of wires and miscellaneous materials, sand filling and plastering over sand filling per location.
Filling earth around location box/signal post for a width of 0.5 m on all sides, upto a level of 150 mm below the foundation top. This work includes consolidation of earth by watering.
Supply of wooden plank(salwood or similar) 940X500X25mm Supply of slotted angle for fixing hylem sheets in steel apparatus cases. (Size 40x40x2mm). Inspection Consignee
"Supply of slotted angle (40 x 40 x 2 mm). Inspection - Consignee."
Supply of paper base hylum sheet 12 mm thick. Inspection - Consignee
Supply of PBT ARA terminal as per IRS SPECN No. IRS:S-75-91 (latest)Inspection: RDSO (i) 6 way
"Carrying out alterations to the existing relay wiring at relay rack / location as per the 28 circuit diagram. The work includes releasing the existing unused wires and wiring the relays using wire PVC 16/0.02 mm copper. { Wire PVC 16/0.02 mm copper, paint, soldering materials and all other miscellaneous materials required for the work shall be supplied by the contractor.) Inspection - RDSO for PVC wire"
Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring of 110mm dia and placing HDPE pipe of size 63/40mm in single /double / triple etc required for crossing/laying of Railway cables in a combination of quad & signalling cables etc. as per required comprising maximum 72 cores in any HDD section on land /bridges /culverts / track / pucca road crossing and blowing / pulling ofQuad /Signalling cables etc. within HDPE pipe. Boring of trench shall be (one) Mtr below the track to 1.5 (one point five) minimum 3 (three) meter below the river bed, 01 meter below other lands including road / pucca road 63/40 29 mm dia & its accessories suitable for HDT as permanently lubricated HDPE pipe ofsize 63/40 crossing area. This includes supply as per Specification No. RDSO/SPN/TC/45/2013 with latest amendment & cost of the fuel and all other items which will be required for laying of cable through it. Inspection : RITES for HDPE pipe (for inspection charges cost of all sort of HDPE pipe is Rs. 195/- per Mtr.) NOTE: The number of HDPE pipes (of any dia as mentioned above) to be pulled in any HDD section will depend upon the numbers of quad / signalling cables to be pulled through that HDD section as per site requirement. At a particular site, the second /additional HDD is to be done only after completing the pulling of 72 cores of cable through 1st HDD other wise the second /additional HDD will not be counted as a new / additional HDD for the purpose of billing.
Termination of cable cores on ARA terminals or on 8 way terminals in the cable termination rack.
Modular disconnecting type terminal block (2 way) with intermediate plate to suite RDSO Spec. RDSO/SPN/189/2004 (Wago or Phonixe or better). Inspection: RDSO
Supply of screw less end stop. Inspection: RDSO
Supply of steel carrier rail. Inspection: Consignee.
Fixing, installation fo disconnect terminal (wago or similar)
Preperation & printing of Station Working Rule Diagram (SWRD)on AUTO CAD besed on approved SIP, ESP etc. as per the extant practice being followed in E.C. Railway. Contrctor shall 35 supply one print of the SWRD (praper print Size as requird) as draft for approval and comments. Once the approval is given shall tracing of the SWRD on good quality flim paper of thickness not less than 75 micorns for signature of all officials. On approval the contractor shall supply 10 copys blue prient of the tracing. The approved SWRD shall be finally supplied on 2 CDs. (Inspection - Consignee)
Preparation of Station Working Rule (SWR) in English and Hindi based on approved SIP, ESP etc as per the extent practice being follwed in E. C. Railway. The contractor shall supply two 36 paper print of the SWR as draft for approval and comments .Once the approval is given he shall supply two paper prients of the SWR for final approval and signature of the concerned officials. on obtaining the final approveal the contractor shall supply 10 sets of the SWR duly photo copies from the original signed off copies of SWR .The approved SWR shall be finally supplied on 2 CDs. (Inspection - Consignee)
Transportation of materials by 15 MT capacity truck or similar.
Loading unloading of heavy S&T materials in 15MT truck.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexDMSDACEIAnnexureANHNBG.pdf
ATTACHMENT
AnnexAE.pdf
ATTACHMENT
OpeningofLC.pdf
ATTACHMENT
TederformfortheTenderer2022.pdf
ATTACHMENT
AnnexVwithcorrection.pdf
ATTACHMENT
PerformaofPoliceVerification.pdf
ATTACHMENT
GUIDELINESTOTHETENDERER.pdf
ATTACHMENT
LatestGCC-2022-ACS6.pdf
ATTACHMENT
CorrectionSlipNo1ofGCC2022.pdf
ATTACHMENT
CorrectionSlipNo2ofGCC2022.pdf
ATTACHMENT
CorrectionSlipNo.3ofGCC2022.pdf
ATTACHMENT
CorrectionSlipNo4ofGCC2022.pdf
ATTACHMENT
CorrectionSlipNo5ofGCC2022.pdf
ATTACHMENT
CorrectionSlipNo.6ofGCC2022.pdf
ATTACHMENT
CorrectionSlipNo7ofGCC2022.pdf
ATTACHMENT
Correctslipno11.pdf
ATTACHMENT
NewfinancialcritariaVIB.pdf
ATTACHMENT
Procedureforundertakingdiggingwork11.pdf
ATTACHMENT
AnnexVIGCC2022.pdf
ATTACHMENT
Receiptcertificatforsuppyonly-AnnexR.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .