Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC VIKASH NAGAR RAMGARH CANTT WARD NO 06 PO PS DISTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | ₹31.6 L | L1 | Accepted-AOC QUOTED AMOUNT IS LOWEST AND REASONABLE |
| 2 | L2₹33.5 LRejected-Finance | ₹33.5 L | L2 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE |
| 3 | L3₹36.9 LRejected-Finance | ₹36.9 L | L3 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE |
| Sl No | Description | Qty | Unit | M/S ROHIT CONSTUCTION L1 | M/S GOLDEN ENTERPRISES L2 | ranjit singh L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches(modular/non modular), ceiling roses, pendants, regulators, sockets,lamp holder , light fitting etc. and removing materials to store for keeping in safe custody or for taking as credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as directed by Engineer-in-Charge. | 314 | Per Point | 40 ₹12,560 | 114 ₹35,796 | 80 ₹25,120 |
| 2.00 | Taking down old unserviceable tube light fitting of any type from wall/ceiling and refixing the same in the existing or other position after repairing all the defects at site. Note: Spares, including fixing for repair works are are to be included in unit quoted rates and not any claim entertained on this account. | 163 | Each | 40 ₹6,520 | 10.5 ₹1,711.5 | 14 ₹2,282 |
| 3.00 | M & L for surface point wiring for one light / fan /exhaust fan points/bell points controlled by one way 5 Amp switch with 1100 volt grade PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable, drawn in & including PVC casing -N- caping/ surface non metallic medium PVC conduit medium grade with fittings (ISI marked) not less than 20 mm size & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet fixed with brass screw for housing/fixing switches etc complete all as specified and directed. Note : Proper coding to be adopted. | 30 | Per Point | 545 ₹16,350 | 540.75 ₹16,222.5 | 620 ₹18,600 |
| 4.00 | All as per item No. 03 mentioned here- in -before but one 3 pin 5 Amp switch socket outlet on independent board complete all as specified and directed. | 10 | Per Point | 545 ₹5,450 | 540.75 ₹5,407.5 | 620 ₹6,200 |
| 5.00 | All as per item No. 03 mentioned here- in- before but one 3 pin 5 Amp switch socket outlet on same board with accessories complete all as specified and directed | 10 | Per Point | 90 ₹900 | 122.25 ₹1,222.5 | 164 ₹1,640 |
| 6.00 | All as per item No. 03 mentioned here-in-before but one 16A socket point controlled by one way 16A switch on independent board with 2.5 sqmm wires complete all as specified and directed | 10 | Per Point | 655 ₹6,550 | 655.5 ₹6,555 | 700 ₹7,000 |
| 7.00 | All as per item No. 03 mentioned here-in-before but one 16A socket/16 A earth plug point controlled by one way 16A switch/20 A MCB on independent board with 4.0 sqmm wires complete all as specified and directed | 10 | Per Point | 990 ₹9,900 | 1,311 ₹13,110 | 1,500 ₹15,000 |
| 8.00 | M & L fo point wiring with 1.5 qmm (Nominal area) FRLSH PVC insulatd and unsheathed single core cable 1100 volts grade with stranded copper conductor in existing conduit along with contineous earth wire 1.5 Sqmm FRLSH PVC insulated, unsheathed stranded copper conductor cable and connected to common earth dolly, with and including 1.6mm cadmium plated sunk MS pressed steel terminal boxes with 3.0 mm thick hylym sheet cover ISI marked fixed with brass screw complete with all accessories for one light/fan/bell point controlled by one 5 Amps single pole one way switch complete all as specified and directed. | 20 | Per Point | 510 ₹10,200 | 463.5 ₹9,270 | 520 ₹10,400 |
| 9.00 | All as per item No.08 mentioned here -in -before but one 3 pin 5 Amp switch socket outlet on same board controlled by one, one way 5 Amp piano switch complete all as specified and directed | 7 | Per Point | 140 ₹980 | 213 ₹1,491 | 280 ₹1,960 |
| 10.00 | All as per item No.08 mentioned here in before but one outlet 5/3 pin 5 Amp switch socket outlet on independent board controlled by one, one way 5 Amp piano switch complete all as specified and directed | 7 | Per Point | 510 ₹3,570 | 463.5 ₹3,244.5 | 520 ₹3,640 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Jan 2026, 6:00 pmClosed
GE RAMGARH CANTT
RAMGARH CANTT
REP REPLACEMENT OF INT WIRING MCCBs DBs SUB MAIN WIRING REP MAINT OF DEEP FREEZER REFRIGERATOR AC WATER COOLERS GEYSERS CEILING FAN EXHAUST FAN WALL MOUNTED FAN AIR CIRCULATOR DESERT COOLER DG SET LT OH LINE UG CABLE FEEDER PILLAR BOXES AT GE RAMGARH
2025_MES_745480_1
8300/3348/E8
Open Tender
Electrical and Maintenance Works
180 days
RAMGARH CANTT
AS PER TENDER DOCUMENT
6 documents required · 6 mandatory
₹500
GE RAMGARH CANTT
₹90,000
Yes
20 Feb 2026
20 Dec 2025
27 Jan 2026
20 Dec 2025
20 Jan 2026
6 Jan 2026
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches(modular/non modular), ceiling roses, pendants, regulators, sockets,lamp holder , light fitting etc. and removing materials to store for keeping in safe custody or for taking as credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as directed by Engineer-in-Charge.
Per 1000 Nos
Supply and fixing in repairs the following unserviceable parts of 12.5 KVA to 82.5 KVA capacity of DG set are as under :-
Supply and fixing in repairs/replacement of engine control panel UNSV parts as under :-
S&F in replacement of ON Load Change over switch of 200 Amps capacity 415 Volts, 4 pole, incl sheet metal enclosure as per the existing switch including taking out old unserviceable one and connection complete all as specified and as directed. Make : L&T / Indo Asian / Hevells .
S&F in replacement of DG Set battery 12 volt, 180 AH as existing for 200 KVA DG set capacity including dismantling of old battery.
ti stranded FRLSH copper conductor cable with continuous earth wire of PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable, drawn in & including PVC casing -N- caping/ surface non metallic medium PVC conduit medium grade with fittings (ISI marked) not less than 20 mm size & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet fixed with brass screw for housing/fixing switches etc complete all as specified and directed. Note : Proper coding to be adopted.
S&F Switch socket combination (SSC) 2 in1, 3 pin,15/16 Amp flush type,universal complete all as specified and as directed.
S&F switch modular single pole one way 6 amp 240 volts,one Module complete all as specified and as directed.
S &F building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65/66 roadway luminaries with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type security lights fitting 35 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nuts, bolts & washers as required at site for fixing of security lights on LT pole/ wall complete including taking old security lights fitting any type and description complete all as specified and directed.
S & F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp breaking capacity 10 KA ,"C" series complete all as specified and as directed.
S&F Inveter LED bulb of capacity 12 watts lumen out put (1200) length 140 mm width 70 mm base cap B22 ,3 star, (ISI marked) complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
S&F in repair LED light fitting 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repair LED luminairs 600mm x 600 mm,35/36 watt,220 volt AC recessed type with high efficiency PMMA diffuser soft free light complete with drivers, holsers, LED lamps suitable roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed.
All as per item No. 03 mentioned here-in-before but one 16A socket point controlled by one way 16A switch on independent board with 2.5 sqmm wires complete all as specified and directed
S&F Switch socket combination (SSC) 2 in 1, 3 pin, 5 Amps flush type,universal complete all as specified and as directed.
S&F in repair Rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed .
S & F Starter switch of capacity 25 amps, working on 240 volts AC supply for air conditioner complete all as specified and directed
S & F in repair sheet metal enclosures Single pole and neutral (SPN), with a two pin earth plug and socket with one single pole MCB 20-32A Amps, complete all as specified and as directed.
M & L for condenser fan blade set for 1.5/2.0 Ton capacity of any type of ACs, suitable for makes of Carrier/Voltas/Amtrex/BlueStar rotation in the casing testing including taking out the defective condenser fan blade all as specified and as directed.
M & L for gas charging with refrigerant gas R-22, R-34 & R-410 in new sealed/eixting unit of compressors ACs/Water cooler/Deep freezer/Refrigerator unit of any type and any size including testing, complete all as specified and as directed by Engineer-in-Charge.
S & F in repair Printed Circuit Board (PCB Board) for any type of AC units suitable for 1.5 TR to 2.0 TR, complete all as specified and as directed by Engineer-in-Charge. Make : Voltas/ Videocon /LG/National aircon/Bluestar/Carrier as approved by GE
S & F in repair cooling motor of existing /suitable capacity for walk in cooler, complete all as specified and as directed by Engineer-in-charge.
S & F in repair remote sensor of existing /suitable capacity for walk in cooler, complete all as specified and as directed by Engineer-in-charge.
S & F in repair controller of existing /suitable capacity for walk in cooler, complete all as specified and as directed by Engineer-in-charge.
S & F in repair capacitor of existing /suitable capacity for walk in cooler of capacity 3.6/4.2 mfd complete all as specified and as directed by Engineer-in-charge.
M & L for repairing of cooling coil,cooling fan ,out door motor ,out door condenser coil for walk in cooler complete all as specified and as directed by Engineer-in-charge. Note:Minor spares required for repairing is deemed to be included in the unit quoted rate.& not any claim entertained on this account at later stage.
M & L for PVC cable 4 Sqmm 3 core unsheathed multi stranded copper conductor including taking down of existing cable complete all as specified and as directed by Engineer-in-Charge.
S & F in repair copper pipe as per existing or suitable size/shape including necessary welding/ brazing/ making threading required length, complete all as specified and as directed by Engineer-in-charge.
S & F new air filter for AC of any size including removal /taking down of existing air filter complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Tenacity/Athelete or equivalent as approved by GE
S & F strainer filter for AC including removal /taking down of existing strainer filter complete all as specified and as directed by Engineer-in-Charge. Make : Voltas/LG/Godrej/Bluestar/Kirloskar/Carrier or equivalent as approved by GE.
S & F in repair air grill for split AC as existing or suitable size/shape/design & make, complete all as specified and as directed by Engineer-in-charge. Make : Voltas/Videocon/LG/National aircon/Bluestar/Carrier as approved by GE
Taking down unserviceable water cooler from the site and transporting the same for repair,removing the unserviceable burnt sealed unit (compressor) from the water cooler and S&F factory made overhauled compressor duly charged with compressor oil including welding in position and testing on required pressure and transporting the water cooler at site in its original location of capacity 40/80 ltr complete all as specified and as directed by Engineer-in-charge. Make –Usha/Arco/Sidhwal. Note: Gas charging,if required shall be measured and paid separately against relevant item.
S & F in replacement of running capacitor (10 mfd) for water cooler 40/80 ltr capacity complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement of starting relay 3 pin for water cooler 40/80 ltrs capacity complete all as specified and as directed by Engineer-in-Charge. .
S & F in replacement of unserviceable float valve with new polythelene ball suitable for 15mm dia GI pipe complete all as specified and as directed by Engineer-in-Charge.
Taking out old unserviceable 15mm dia water tap and S&F new self closing chromium plated push cock of 15mm dia heavy duty complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement of freezer door (plastic) complete with tension spring as per original complete all as specified and directed by Engineer -in-Charge.
Taking down old defective over load protector & S&F new over load protector of suitable capacity/size for 40/80 ltr capacity water cooler complete all as specified and as directed by Engineer-in-Charge.Make –Renutral/Techno mech.
S & F in replacement of unserviceable tray with new as per original complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of fruit/vegetable tray as per original complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of door liver (plastic) as per original complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of door magnetic gasket as per original make for any capacity of Refrigerator complete all as specified and directed by Engineer -in-Charge.
S & F in repair starting capacitor of suitable size/capacity for 40/80 ltr capacity water cooler complete all as specified and as directed by Engineer-in-Charge. Make : Asian/Unistar/Arvind.
S & F in replacement of ice chamber as per original complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of unserviceable relay PTC single pole for any type and any capacity of refrigerator complete all as specified and directed by Engineer -in-Charge.
Opening of regrigator of any capacity for servicing and refixing the same after flushing out and removal blockage, brazing replacement of liquid line filter and recharging the regrigation gas R-22 to obtain the desired cooling complete all as specified and directed by Engineer -in-Charge.
M&L for spray painting of refrigerator with synthetic enamel paint after preparation of old surface of refrigerator capacity 310/286/165 ltr of any make/model complete all as specified and directed by Engineer -in-Charge.
Taking out deep freezer of any capacity from the site for complete servicing of Deep freezer units by electically disconnecting the units and cleaning the compressor , condenser , piping suction/discharge suction, fan motor, cooling coils, cooler body and connected accessries with the help of blower unit , cleaning the same with water and caustic soda for condenser and piping unit , tighten all nuts , bolts, screws etc checking the door bedding , electrical controls of the cooling units rectify where necessary and refixing in its original site and testing comlete all as specified and directed by Engineer-in-charge
Taking out old unserviceable internal wiring and rewiring with same guage and size with flexible copper conductor of suitable size with terminal clips etc including screws, washers etc required for fastering with body complete all as specified and as directed by Engineer-in-Charge.
Taking down rusted front and back body mild steel sheet cover and S&F new 2.0 mm thick mild steel plate cover of duly painted to match the existing of water cooler complete all as specified and as directed by Engineer-in-Charge.
S & F new sealed unit compressor for deep freezer as per existing make and size & capacity as approved by GE complete all as specified and as directed by Engineer-in-charge.
Taking out old unserviceable fan motor and S&F new fan motor of suitable size/capacity for existing water cooler 40/80 ltr capacity complete all as specified and as directed by Engineer-in-Charge.
M&L for cleaning of water cooler complete internally and externally including scraping and complete removing of existing treatment/paint, scales and dirt etc.and applying of two coats of synthetic enamel paint over a coat red oxide primer all as specified and as directed.
Taking down unserviceable refrigerator of capacity 250 Ltr to 310 ltr from the site and transporting the same to work shop for repair/removing unserviceable burnt sealed unit (compressor) and supply and fix factory made overhauled compressor duly changed with compressor oil including welding in position and testing on required pressure and transporting back to its site and fix in original location complete all as specified and directed by Engineer –in-Charge.
Taking down unserviceable refrigerator of capacity 165 ltr to 1
90 Ltr from the site and transporting the same to work shop for repair/removing unserviceable burnt sealed unit (compressor) and supply and fix factory made overhauled compressor duly changed with compressor oil including welding in position and testing on required pressure and transporting back to its site and fix in original location complete all as specified and directed by Engineer –in-Charge.
S & F running capacitor 10 mfd including taking out capacitor complete all as specified and as directed by Engineer-in-charge.
M & L for body patching including denting at certain place of deep freezer and then spray painting with match of existing finishing complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of pgmy lamp (bulb) as per the existing complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of unserviceable over load protection with new for any type and any capacity of refrigerator complete all as specified and directed by Engineer -in-Charge.
S&F Thermostat rod type including rubber/ PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 /35/ 50 ltrs including taking down existing unserviceable thermostat complete all as specified and as directed.
S&F Thermostat tai
l type including rubber/ PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 /35/ 50 ltrs including taking down existing unserviceable thermostat complete all as specified and as directed.
S&F PVC connecting pipe 18" long with brass adopters for hot and cold water and connecting up with complete for 25 /35/ 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe complete all as specified and directed.
S&F bottom covers (set of two halves) duly painted made out of Aluminium /MS sheet of 18 SWG suitable for 25 /35/ 50 ltrs capacity Geysers including taking down existing unserviciable bottom covers complete all as specified and as directed.
S & F in repair fan motor of suitable size/capacity for deep freezer complete all as specified and as directed by Engineer-in-Charge.
S&F base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly complete all as specified and as directed.
S &F in replacement inner stainless steel dome of geyser of capacity 25 Ltrs complete as per sample to match original patterns and shape complete all as specified and as directed by the Engineer -in Charge.
S & F in repair relay of suitable size/capacity for deep freezer as per sample complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement of Voltage stablizer digital display type for automatic operation, single phase naturally air cooled indoor type & designed for input variation between I/P Correction Range of 140 - 280 volt with output voltage stablized at 230 V with accuracy of + 2.5 % and capacity 5 KVA complete all as specified and as directed. Make –V-Guard,Havells,Bajaj,Usha,Crompton,Khaitan
S & F in repair heating element including rubber gasket & washer etc. of capacity 2 KW suitable for existing make and shape complete all as specified and directed.
S &F in replacement inner stainless steel dome of geyser of capacity 35 Ltrs complete as per sample to match original patterns and shape complete all as specified and as directed by the Engineer -in Charge.
Disconnecting carefully water and electric connection from storage type water heater of 25/50 Ltr capacity of any make and dismantling for repair by taking out the syphon assembly of thermostat, heating element and cleaning, de-scaling the inner tank by de-scaling with chemical compound including soldering, brazing the inner tank, if required, re-assembling the geyser after cleaning & servicing including replacement of flexible cable of size 2.5 sqmm 3 core with copper conductor up to 1.5 mtr long and re-fixing in existing position complete all as specified and directed. Note:- The rate quoted is deemed to include cost of soldering/brazing work and glass wool superior quality, if required at site.
S & F in repair heating element including rubber gasket & washer etc. of capacity 1.5 KW suitable for existing make and shape complete all as specified and directed.
S & F in repair heating element including rubber gasket & washer etc. of capacity 3 KW suitable for existing make and shape complete all as specified and directed.
Supply only safety valve of suitable size/capacity for geyser chromium plated brass 15 mm dia all as specified and directed.
S&F indication lamp of suitable size/capacity for 25/35/50 ltrs capacity Geysers including taking down existing unserviceable indication lamp complete all as specified and as directed.
M&L for preparation of surface of geyser 25/50Ltrs capacity by scrapping and applying one coat of sythetic enamel paint of approved colour including tinkering and welding, if required at site complete all as specified and as directed.
S & F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp breaking capacity 10 KA ,"C" series complete all as specified and as directed.
Taking down carefully by disconnecting electrical connection of unserviceable ceiling fans/exhaust fans of any sweep and size from its position at different locations in cantt area and removing the same fan to MES store yard to keep in safe custody for repairing/overhauling and refixing/ re-installation of repaired/serviceable fans (taken from MES store yard) to the different locations in cantt area complete all as directed by Engineer-in-charge. Note : Transportation of ceiling fans/exhaust fans from site location to MES store yard & back( MES store yard to site location )shall be made through proper issue/receipt voucher duly mentioning by MES rep.
S & F in repair PVC insulated copper cable of size 2.5 Sqmm 3 crore to any capacity geysers as required length complete all as specified and as directed.
Supply only Gun Metal bush of suitable size/capacity for 1200/1400 mm sweep ceiling fans complete all as specified.
Servicing exhaust fans of 450 mm /300 mm/225 mm /any sweep and size for repairing/ overhauling by cleaning/ greasing/oiling etc. and re-assembling the same after and including replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items) complete all as directed by Engineer-in-Charge.
Servicing ceiling fans of 1200mm/1400mm/ any sweep and size for repairing/overhauling by cleaning/greasing/oiling etc. and re-assembling the same after and including replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items here-in-after) complete all as directed by Engineer-in-Charge.
M&L for cutting of existing winding of ceiling fans of 1200 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive.
M&L for cutting of existing winding of ceiling fans of 1400 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-Charge. Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive.
S & F in repair Plug Top 15A, 230 Volt, AC complete all as specified and directed by Engineer-in-Charge.
Supply only ball bearing SKF 6202/6201/equivalent suitable for 1200/1400 mm sweep ceiling fans complete all as specified.
S &F in repair mild steel clamps of suitable size & shape with rubber reel, nut bolts with washer and including spliting pin suitable for 1200 mm/1400 mm sweep of ceiling fans complete all as specified & directed.
M&L for cutting of existing winding of exhaust fans of 300 mm/250 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-Charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-Charge/concerned ground executive.
M&L for cutting of existing winding of exhaust fans of 450 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing
complete all as specified & directed by Engineer-in-Charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-Charge.
S &F in repair 2.5 mfd capacity capacitor of suitable for ceiling fans of 1200 mm/1400 mm sweep of approved make complete all as specified & directed by Engineer-in-Charge.
S &F in repair 4/6 mfd capacity capacitor of suitable for ceiling fans of 300 mm/450 mm sweep of approved make complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove only dust etc. and applying two coat of synthetic enamel (white shade) paint and marking MES number with non erasable marker pen with black colour complete all as specified & directed by Engineer-in-charge.
S & F in repair stepped socket type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
S&F louvers for Exhaust Fan of size 250 mm to 450mm sweep steel suitable for existing shape and size including taking down existing unserviceable /rusted louvers complete all as specified and as directed by Engineer in Charge.
S&F in repair for Front Grill Double Partition type of 20 SWG metal grill, best quality (as approved) of suitable size for Desert Cooler providing making Electric Connection to all accessories as required including taking out/ down unserviceable one, complete all as specified and as directed.
S & F in repair for motor suitable 1/7 HP, 180 watt, 3 speed for Desert Cooler, copper wounded complete and one set of lugs for mounting body including taking out/ down unserviceable one, complete all as specified and as directed. Make: Khaitan(A-029) or equivalent in CG/Blueline
S &F in repair down rod for hanging of ceiling fan, fabricated /made out of 15mm dia heavy grade mild steel conduit (length of conduit not less than 550 mm long & wall thickness not less than 1.5mm) with suitable fan clamps duly painted with two coat of synthetic enamel (white shade) paint over a coat of primer complete all as specified & directed.
Removal of surplus excavated spoil not exceeding 50 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
S & F in replacement cooler stand made out of equal angle iron (size 30 mm x30 mm x 3mm ) with 25 mm cross support between angle frame and both side of front and back stand legs for desert cooler with applying one coat of synthetic enamel paint over a coat of red oxide primer on exposed surface of stand complete all as specified and directed.
S&F for 15 mm dia Plastic PVC distributor suitable size for Desert Cooler heavy duty with elbow, Tee, etc. fixed with bolts, nut & washers including taking out/down unserviceable one, complete all as specified and as directed.
S & F Plastic PVC Pipe( ISI mark) of 15mm bore suitable for Desert Cooler, heavy duty, including taking out/down unserviceable one, complete all as specified and as directed.
S &F in repair down rod for hanging of ceiling fan, fabricated /made out of 15mm dia heavy grade mild steel conduit (length of conduit not less than 1250 mm long & wall thick ness not less than1.5 mm) with suitable fan clamps duly painted with two coat of synthetic enamel (white shade) paint over a coat of primer complete all as specified & directed.
S&F Grass Wool Pad (as approved) suitable for Desert Cooler, heavy duty and best quality including taking out/ down unserviceable one, complete all as specified and as directed.
M&L preparing old surfaces of Desert Cooler Body by descaling, rubbing, brushing, cleaning and applying one coat of synthetic enamel paint (as approved) with spray gun machine of outer surface of cooler and inner side of tank with black bituminous paint complete all as specified and as directed.
Excavation in trenches in hard dense soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations, shafts, well, cesspits, manholes etc.complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb/benching/ copings including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed
M&L for plain cement concrete 1:3:6 ,type C-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
M&L for plain cement concrete 1:4:8 ,type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
Supplying and laying old size sub class “B” bricks kiln brunt, neatly laid adjacent to each other with axis of bricks perpendicular to the axis of cable for cable protection complete all as specified and directed.
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 10 Sq mm to 16 Sq mm any core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including excavation, RFR, removing of excavated soil, connecting & testing complete all as specified and directed by Engineer-in Charge. (Note: sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
All as per item No. 03 mentioned here-in-before but one 16A socket/16 A earth plug point controlled by one way 16A switch/20 A MCB on independent board with 4.0 sqmm wires complete all as specified and directed
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 20 Sq mm to 50 Sq mm any core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including excavation, RFR, removing of excavated soil, connecting & testing complete all as specified and directed by Engineer-in Charg
e. (Note: sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 70 Sq mm to 95 Sq mm any core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including excavation, RFR, removing of excavated soil, connecting & testing complete all as specified and directed by Engineer-in Charge. (Note: sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 120 Sq mm any core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including excavation, RFR, removing of excavated soil, connecting & testing complete all as specified and directed by Engineer-in Charge. (Note: sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor, 1100 Volts grade of cross sectional area 120 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 95 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 70 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 50 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 35 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 25 Sq mm 4.0 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 16 Sq mm 4.0 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 10 Sq mm 4.0 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supplying and fixing as in replacement MCCB four pole 63 amps 415 volt , 50 Hz breaking capacity not less than 16 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 100 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 160 amps 415 volt , 50 Hz breaking capacity not less than25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 200 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 250 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 315 amps 415 volt , 50 Hz breaking capacity not less than 36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
S &F in repair mild steel hooks fabricated/made out of flat iron 50 mm x 6mm including nut, bolts (6-8 mm dia & 40 to 50 mm long with spring washer) complete all as specified & directed by Engineer-in-Charge.
Supplying and fixing as in replacement MCCB four pole 400 amps 415 volt , 50 Hz breaking capacity not
S &F in repair PVC flexible wire of size 23/.0076 Sqmm or 0.50 sqmm multi stranded, twin core, PVC sheathed copper conductor complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove only dust etc. and applying one coat of synthetic enamel (white shade) paint and marking MES number with non erasable marker pen with black colour complete all as specified & directed by Engineer-in-Charge.
less than 36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 630 amps 415 volt , 50 Hz breaking capacity not less than 36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Dismentling old and unserveciable stay assembly complete comprising of stay clamp, stay wire, stay insulator, stay grip, thimble, bow, stay rod 16 mm dia and stay plate etc including breaking of cement concrete complete all as specified and as directed.
M&L for stay assembly complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps excavation and concrete measured separately), stay rod of size 20 mm dia complete all specified and directed .
Dismantling old and unserviciable prestressed concrete poles/steel tubular poles of any type including breaking cement concrete complete and site clearance .
Supply and laying GI pipe 80 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one complete all as specific and as directed.
Supply and laying GI pipe 50 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one complete all as specific and as directed.
Supply and laying GI pipe 40 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one complete all as specific and as directed.
S & F in repair blade set of suitable size/capacity for ceiling fan 1200 mm/1400 mm sweep of any make as per site requirement complete all as specified and as directed.
S & F in repair ACSR (Aluminium conductor, steel reinforced) conductor of (weasel) 6/1 X 2.59 mm, streching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge
S & F in repair metal blades set of suitable size for exhaust fan 300 mm/450mm sweep any make as per site requirement complete all as specified and as directed.
S & F in repair PVC blades set of suitable size for exhaust fan 300 mm/450mm sweep any make as per site requirement complete all as specified and directed.
S & F in repair Aluminium thimbles of size 16 Sq mm to 35 Sqmm of 3.5 core /4 core and including removing burnt thimbles from existing XLPE Cables & cable made to suitable for fixing new thimbles complete all as specified and directed.
S & Fin repair for metal fan blades of best quality of suitable size for Desert Cooler of any make and size including taking out/ down unserviceable one, complete all as specified and as directed.
S & F in repair Aluminium thimbles of size 50 Sq mm to 95 Sqmm of 3.5 core /4 core and including removing burnt thimbles from existing XLPE cables & cable made to suitable for fixing new thimbles complete all as specified and directed.
S & F in repair Aluminium thimbles of size 120 Sq mm to 185 Sqmm of 3.5core/4 core and including removing burnt thimbles from existing XLPE Cables & cable made to suitable for fixing new thimbles complete all as specified and directed.
M&L for Pin type Porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade including dismantling /disconnecting & taking down of existing insulaters of any size & capacity complete all as specified and directed.
S & F in repair cross arms bracing supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminum paint complete all as specified and directed.
Supply and fix, in replacementt Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size 20 cm x 15cm for LT complele all as specified and as directed.
M&L for Earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth wire of size 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing testing point all as specified and directed including excavation and connected earth work in hard/dense soil, PCC 1:3:6 ,type C-1(using 20 mm graded crushed stone aggregate ) as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm dia bore GI light grade pipe as earth lead protection pipe, 50 mm thick pre-cast RCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in cover slab of size 300 mm x300 mm x 50mm as earth pit cover slab with & including 8 mm dia TMT bars @ 100 mm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing also including taking down of old /unserveciable earthing on completion complete all as specified and directed. Note: (i) Earth wire/ strip and its protection pipe up to and including 7.5 mtr only from the top of earth electrode. (ii) Rate quoted deemed to be included excavation and earth work in any type of soil with PCC in pit PCC Cover & other arrangement complete all as directed.
Supply only 3.15 mm thick mild steel sheet alongwith one coat of red oxide primer with help of spary gun machine complete all as specfied and directed.
Supply only aluminium bus bar of different size and different capacity, as per site requirement and as directed by Engineer-in-Charge including PVC insulating materials and cutting, welding as required, making holes and fixed in position in replacementt (taking down old bus bar) complete all as specified and as directed.
S& F in repair of LCD multi functional metre 50 to 55 VAC capacity three phase square type complete all as specified and as directed.
Supply only LED indication Lamp (Red) complete all as specified and as directed.
Supply only LED indication Lamp (Yellow) complete all as specified and as directed.
S&F Submersible water Pump of suitable size/capacity for Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed.
Supply only LED indication Lamp (Blue) complete all as specified and as directed.
M & L for removing of damaged steel structure base frame of LT panel board and fabricating new steel structure base frame with size of existing frame equal angle of size 50 mm X 50 mm X 6 mm thick and screwing with existing panel board including two coat of synthetic enamel paint over a coat of red oxide primer with preparation of surface complete all as specified and directed.
All as per item No.08 mentioned here -in -before but one 3 pin 5 Amp switch socket outlet on same board controlled by one, one way 5 Amp piano switch complete all as specified and directed
M&L sand filling in cable trenches for cable protection for clean dry sand unwashed including gently punning in a layer of 15 cm and 8 cm (total 23 cm) inthickness all across the laid portion of LT cable in trenches complete all as specified and directed. (Note:-Punned thickness shall only be considered for payment)
Removing wild grass, vegetation, creeper etc around LT panel/ installations, climbing up towards poles and stay assembly including cleaning bottom surface of pole, stay assembly of area not less than 1m x 1m by surface dressing not exceeding 0.5 m deep in soft/loose soil complete all as specified and directed by Engr-in-Charge.
S&F replacement of LT bus bar chamber box of minimum size 70 cm x 50 cm x 30 cm outdoor type double door/front door front/rear opening type suitable for 415 volt 3 phase, 4 wire (100% neutral), 50Hz supply system Box made out of 3.15mm thick (outer) & 2mm thick (innder compartment door) CRCA sheet factory made weather proof, dust ve
rmin proof and vermin proof duly powder coated with 04 Nos, copper bus bar 100 Amps rated ,40 cm each (each bus bar having 04 Nos of nuts, bolts, washer) horizontally place in insulator suitable for lockable door arangement complete with inter connctions with copper solid strips, bus bar chamber having 4 nos legs 45cm long of 40 mm x 40 mm x 6 mm angle iron, 15 cm long grouted in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) and 30 cm clear space from complete all as specified and directed.
S&F in replacement of off load changeover switch 415 volt in sheet metal encloser 4 pole of capacity 200 Amp complete all as specified and directed.
(a) 12.5 KVA to 63 KVA 3 phase 50 Hz
(b) 82.5 KVA to 125 KVA 3 phase 50 HZ
Supply and fixing in repairs loop type insulators, vitreous porcelain, white, brown or greeen of large size, with overall dimensions 140 mm, clearance of hole 25.5 mm complete all as specified and directed. Make: Bengal Potteries/ Jayashree/ Mysore Porcelain/ Jaipuria/ Bhel/ Southern Insulators/ WS Insulators.
Removing wild grass, vegetation, creeper etc around LT panel/ installations, climbing up towards poles and stay assembly including cleaning bottom surface of pole, stay assembly of area not less than 1m x 1m by surface dressing not exceeding 0.5 m deep in soft/loose soil complete all as specified and directed by Engr-in-Charge.
(a) Fuel filter element.
(b) Oil Filter element .
S&F in replacement of off load changeover switch 415 volt in sheet metal encloser 4 pole of capacity 200 Amp complete all as specified and directed.
(c) Air Filter.
(b) 82.5 KVA to 125 KVA 3 phase 50 HZ
(d) By pass filter.
(e) Fan belt.
Supply and erection of steel tubular pole swaged type 410-SP -31 (09.0 mtr long pole) swan neck type complete conforming to IS: 2713 complete with mild steel base plate, finial taper plug pole cap, mild steel bolt, nuts and screws,painting of pole externally with one coat of black bituminous paint (upto planting depth) and remain exterior portion of the pole shall be painted with two coats of aluminium paint over a coat of primer with blue & white strip upto 1.20 m height above GL and all as specified and directed with two coat of aluminum paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 5 Nos with yellow and black paint of radium/photosinthetic paint alternately on external surface above base / copingr upto the height of 1.5mtr above plinth block,writing letter or figures (Block Roman) with thick synthetic enamel paint of approved shade not exceeding 5 cm height including numbering of pole, Painting coping with two coats of cement based paint etc complete all as specified and directed. NOTE : (i) All excavation and earthwork ,PCC shall be measured and paid separately under respective items of BOQ. (ii) Manufacture's test certificate for pole shall be produced before execution work.
Removing wild grass, vegetation, creeper etc around LT panel/ installations, climbing up towards poles and stay assembly including cleaning bottom surface of pole, stay assembly of area not less than 1m x 1m by surface dressing not exceeding 0.5 m deep in soft/loose soil complete all as specified and directed by Engr-in-Charge.
(f) Radiator hose pipe of suitable size.
rmin proof and vermin proof duly powder coated with 04 Nos, copper bus bar 100 Amps rated ,40 cm each (each bus bar having 04 Nos of nuts, bolts, washer) horizontally place in insulator suitable for lockable door arangement complete with inter connctions with copper solid strips, bus bar chamber having 4 nos legs 45cm long of 40 mm x 40 mm x 6 mm angle iron, 15 cm long grouted in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) and 30 cm clear space from complete all as specified and directed.
S&F in replacement of off load changeover switch 415 volt in sheet metal encloser 4 pole of capacity 200 Amp complete all as specified and directed.
(a) 12.5 KVA to 63 KVA 3 phase 50 Hz
(b) Oil Filter element.
(c) Air Filter.
M&L for painting to existing steel tubular/concrete LT poles, 8.5m/9m/9.5m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality dust proof and weather proof of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint of radium/ photosinthetic paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers with bold letters with black and white paint after painting complete all as specific and as directed.
(e) Fan belt.
M & L for shackle type porcelain, vitreous, white, brown or green Two-in-series' assembly for tension with tension clamps for conductors, working pressure 1100 volts insulator 65 mm dia X 31 mm high X 20mm hole ball and socket type working pressure 1100 volts grade including dismantling /disconnecting & taking down of existing insulaters of any size & capacity complete all as specified and directed.
(g) V-belt BX-40.
(h) V-belt AVX 3/1562.
(b) Oil Filter element.
(f) Radiator hose pipe of suitable size .
Supply and filling / top-up coolant for DG set of any capacity all as specified and directed. Make : GULF / MICO /Castrol
Checking/Servicing of DG Set battery 12 volt, 92/ 180 AH cleaning of battery terminals by hot water and applying petrolium jelly over battery terminals, water level checking including topping up with distilled water complete all as specified and directed (Note - Bettery terminal, Battery cable and distilled water will be measured and paid separatly)
Material and labour for Fibre LT over head line seperators suitable size for 4 wires fixing on LT OH lines including dismantling of old damaged/ Un-serviceable LT line spacers of any type complete all as specified and directed.
(a) Heavy duty brass battery terminal
(b) Battery lead 70 Sqmm multistandard, single core, copper conductor
(c) Distilled Water of approved make
Material and labour for Fibre LT over head line seperators suitable size for 2 wires fixing on LT OH lines including dismantling of old damaged/ Un-serviceable LT line spacers of any type complete all as specified and directed.
Taking down & repairs of radiator assy of DG set of capacity 12.5 KVA to 63 KVA from engine mounting by opening water hose and nut bolt cleaning of radiator inside and out side with anti rust solution, checking the radiator by filling water and repairing for any leakage by brazing the radiator and ensure for no leakage Re- fixing the radiator at place including transportation for repair to workshop or site all as directed.
Taking down & repairs of radiator assy of DG set of capacity 82.5 KVA to 125 KVA from engine mounting by opening water hose and nut bolt cleaning of radiator inside and out side with anti rust solution, checking the radiator by filling water and repairing for any leakage by brazing the radiator and ensure for no leakage Re- fixing the radiator at place including transportation for repair to workshop or site all as directed.
Dismantling & repairs of the fuel injection pump from engine block of DG set of 30 KVA to 63 KVA disconnecting all fuel inlet and outlet lines, disconnecting the drive for carrying out repairs/ replacements including calibration, re assembling of FIP and fixing back in position after repair / replacement of unserviceable parts all as directed. Note :- 1. Calibration of FIP complete shall be got done from manufacturer authorized dealer/ workshop to entire satisfaction of Engineer- in- charge. 2. Shifting and loading/Unloading of FIP and transporting for repair in workshop at Ramgarh/ Ranchi city from existing location/site is including in deemed rate.
Taking down unserviceable self starter 24 Volts for DG sets, serviceing and replacement of old carbon brushes, bearing and contact blades etc and refixing after servicing and making serviceable with replacement of unsv parts complete all as specified and as directed. (NOTE : Bearing of alternator will be measured and paid separately)
Taking down unserviceable alternator suitable for 12 Volts for DG sets, serviceing and replacement of old carbon brushes, bearing and contact blades etc and refixing after servicing and replacement of unsv parts. (NOTE : Bearing of alternator will be measured and paid separately)
Dismantling & repairs of the fuel injection pump from engine block of DG set of 12.5 KVA to 82.5 KVA disconnecting all fuel inlet and outlet lines, disconnecting the drive for carrying out repairs/ replacements including calibration, re assembling of FIP and fixing back in position after repair/ replacement of unserviceable parts all as directed. Note :- 1. Calibration of FIP complete shall be got done from manufacturer authorized dealer/ workshop to entire satisfaction of Engineer- in- charge. 2. Shifting and loading/Unloading of FIP and transporting for repair in workshop at Ramgarh/ Ranchi city from existing location/site is including in deemed rate
(a) Nozzle plunger.
Cutting branches /plants / bushes obstructing at over head LT/HT line including cleaning /levelling / cutting of undue surfaces & disposal of materials upto a distance not exceeding 50m complete all as specified and directed by Engineer-in-Charge.
(b) Delivery valves.
(c) Injector holder with washers.
(d) Injector.
(e) FIP packing Kit.
(f) Bearing number 30203 or suitable existing matching number
(g) Bearing number 6203 or suitable existing matching number
Disconnection of electric connection from DG set of any description and in any position, for servicing, taking out & removing unserviceable/defective parts/spares, cleaning, servicing, oiling and greasing of necessary parts, refixing the serviceable parts in position after servicing, replacement of unserviceable parts including draining-out of existing engine oil and filling new engine oil of same grade and filters, refixing of all accessories and testing on full load complete all as specified and directed for following capacity of DG sets :-
(a) Oil Pressure Gauge as per approved Make
(b) Oil Temperature Gauge as per approved Make
Supply only the following parts of DG set of capacity 12.5 KVA to 63 KVA :-
Supply only the following parts of DG set of capacity 82.5 KVA to 125 KVA :-
(c) Hours meter as per approved Make
(d) Ampere meter as per approved Make
(e) Volt meter as per approved Make
Taking down & repairs of old turbo charger assembly from engine mounting by opening nut, bolt and transporting to civil workshop for repairing,cleaning and servicing from inside and outside with anti rust solution, checking the same and repairing for any leakage by brazing the turbo charger and ensure for no leakage. Refixing the turbo charger at same place of 30 KVA to 63 KVA capacity DG set. Note:- Transportation cost included in unit quoted rate.
M& L in replacements of PVC coolant makeup bottle of cap 3.5 Ltr suitable for 30 KVA DG set as existing complete all as specified.
M& L in replacements of PVC coolant makeup bottle of cap 6.5 Ltr suitable for 82.5 KVA to 125 KVA DG set as existing complete all as specified.
S&F in replacement of ON Load Change over switch capacity upto 63 Amps capacity 415 Volts, 4-Pole incl sheet metal enclosure as per the existing switch including taking out old unserviceable one and connection complete all as specified and as directed. Make : L&T / Indo Asian / Hevells .
S&F in replacement of ON Load Change over switch of 100 Amps capacity 415 Volts, 4- Pole incl sheet metal enclosure as per the existing switch including taking out old unserviceable one and connection complete all as specified and as directed. Make : L&T / Indo Asian / Hevells .
S&F in replacement of ON Load Change over switch of 160 Amps capacity 415 Volts, 4 pole, incl sheet metal enclosure as per the existing switch including taking out old unserviceable one and connection complete all as specified and as directed. Make : L&T / Indo Asian / Hevells .
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
3348TENDERDOCS.pdf
Tender Documents • 2.35 MB
BOQ_834741.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid