Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹24.3 L+₹40,013 (1.67%)Rejected-AOC 79B MIG PHASE 1 INDIRA PURAM G M S ROAD DEHRADUN UK PIN 248171 | DEHRADUN | UTTARAKHAND | 248171 | L2 | Rejected-AOC R | |
| 3 | L3₹25.2 L+₹1.3 L (5.26%)Rejected-AOC 67 PATEL NAGAR NEW MANDI MUZAFFARNAGAR INDEX NO C 630 HQ CE WC | L3 | Rejected-AOC R | |
| 4 | L4₹25.2 L+₹1.3 L (5.50%)Rejected-AOC 1 259 CHUKKUWALA DEHRADUN UK | DEHRADUN | DEHRADUN | UTTARAKHAND | L4 | Rejected-AOC R | |
| 5 | L5₹25.5 L+₹1.5 L (6.36%)Rejected-AOC PLOT NO 4 NAYA GAON HARIPUR KANWALI P O SEEMADWAR DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-AOC R |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
7 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
REPAIR TO ROOF OF CERTAIN BLDG IN CR CAMP AND MT COLONY UNDER AGE B/R-I AT IMA DEHRADUN
2021_MES_428987_1
GE/IMA-05/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
AOR of GE IMA Dehradun
Refer NIT
8 documents required · 8 mandatory
₹500
GE IMA Dehradun
₹80,000
Yes
19 Apr 2021
8 Mar 2021
9 Apr 2021
9 Mar 2021
7 Apr 2021
23 Mar 2021
60 days
Amount
A coat of cold applied bituminous primer over cleaned surface @ 0.30 Kg/Sqm and applying one coat of hot blown bitumen 85/25 grade @ 1.20 Kg/Sqm followed by APP modified five layer polymeric membrane 3mm thick, minimum weight 3.60 kg/sqm reinforced with polyester non-woven fabric (weighing not less than 150 gms/sqm) manufactured by authorised manufacturer specified in particular spicification, laid as per the manufacturer instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical surfaces and applying one coat of hot blown bitumen 85/25 grade @ 1.20 Kg/Sqm finally finished with bituminous aluminum paint @ 0.20 Kg/Sqm complete including taking down existing roof treatment the RCC slab, cleaning off all foreign material by wire brushing, cleaning off surface and removal of spoil to a distance n.exc 500m complete all as directed. Note:- The work shall be executed through authorised applicator approved by GE.
20mm thick screed bed in CM 1:4 on roof surface finished even and smooth mixed with water proofing compound as per manufecturer's instructions including taking down existing cement plaster including racking out joints,hacking for key, scrubbing down with water etc.complete all as directed. Note : WPC will be measured and paid separately as supply only.
Pre- painted colour galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of green colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as directed including dismantling existing sheet.
Pre- painted colour galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of red colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as directed including dismantling existing sheet.
Pre- painted colour galvalume aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of Green colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges fixed with self tapping screws etc complete all as directed including dismantling existing sheet.
Demolition of old brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6.00m mean radius built in CM (1:6) complete all as specified and directed.
Brick work with sub class 'B' bricks (except bricks) straight or curved on plan exc 6.00m mean radius built in CM (1:4) complete all as specified and directed.
Brick work with sub class ‘B’ bricks (old size), straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone walling built in CM including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Rendering 15mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement and mixed with water proofing compound as per manufactures instructions, complete all as specified and directed Note- WPC will be measured paid as supply only under respective items separetely.
Rendering 15mm thick plaster on other than fair faces of brick work or concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Rendering 5mm thick plaster in CM (1:3) on concrete surface of ceiling finished even & smooth without using extra cement complete all as specifiied and directed.
Supply only liquid water proofing compound complete all as specified & directed.
75 mm thick PCC 1;3:6 type C-2 using 40mm graded stone aggregate as in plinth protection or similar places and finishing the surface even & smooth with out using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meter and every change of direction and filling the same with mixture of bitumen & sand in ratio (1:1) by weight including necessary form work etc and including demolition of existing old cement concrete, complete all as specified and directed.
500 Litres capacity rotational moulded polyethylene water storage tanks, three layered, ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including 20mm dia GI light grade washout pipe 50mm long with plug and 20mm dia GI light grade over flow pipe 600mm long with fitting including dismantling of existing unserviceable tank and removing from site complete all as specified and directed.
Ball valve 15mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball min weight 210 gms fixed in repair complete all as specified and directed.
Ball valve 20mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball min weight 210 gms fixed in repair complete all as specified and directed.
20mm bore gun metal globe/gate valves, with iron wheel head, screwed both ends for iron/GI pipe fixed in repair complete all as directed. Make: Zoloto/Leader/Kirloskar/Upadhyay/Audco
100 mm thick PCC 1:2:4 (20mm graded crushed stone aggregate) as in floor/hard standings and making impressions with spike rolling or expanded metal whilst the concrete is green, finishing exposed edges fair or rounding or chamfering of exposed edges also filling in uneven surfaces to make it level including making joints 12mm wide to the full depth of PCC at panel size n, exc 2.0mx 2.0m and filling the same with sealing compound grade 'A' including necessary formwork including demolition of existing old cement concrete floor etc complete all as specified and directed.
40mm thick PCC type B1 1:2:4 (20mm graded crushed stone aggregate) as in floors and finishing the concrete even and smooth using extra cement including demolition of existing old cement concrete floors etc complete all as directed.
Glass dividing strips 3mm thick and 38mm wide inserted in position and confirm to design complete all as directed.
PCC 1;4;8 type D-2, using 40 mm graded stone agg as in foundation, filling, mass concrete and sub base of floor including demolition of existing old concrete complete all as specified and directed
Rubberised precast coloured concrete Interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade complete with and including 25mm thick sand cushioning layer including dismantling of existing damaged flooring etc complete, all as specified and directed.
Rubberised precast coloured concrete Interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade complete with and including 25mm thick sand cushioning layer including dismantling of existing damaged flooring etc complete, all as specified and directed.
25mm thick Fiber reinforced heavy duty cement concrete tile of any pattern decided by Engr-in-charge as in floors/pavings laid over 20 mm thick screed bed 1:6 laid and jointed with white cement slurry mixed with pigment to match the shade of tile complete including dismantling of existing tiles with screed bed of any description and in any position complete all as specified and directed.
25mm thick PCC 1:2:4 type B-1 (using 20mm graded agg) used as sub floor finish the surface to receive to tiles including demolition of existing old cement concrete floors etc complete all as directed.
15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including taking up or down existing steel tubing pipe complete all as directed.
20mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including taking up or down existing steel tubing pipe complete all as directed.
Udaipur green marble work 18 to 20 mm thick (table rubbed and polished) as in flooring, steps, cooking platform and like with and including 20 mm thick cement screed bed in CM 1:6 and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of slab including rounding of edges of udaipur green stone and demolition of existing stone slab or tiles with screed bed of any description and in any position complete all as specified and directed.
Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking bending spirally for hooping for columns hocking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Precast RCC 1:2:4 Type B-1 (using 20 mm graded crushed stone aggregate) as in cover slab, set and jointed in CM 1:4 incl demolition of existing old RCC slabs of any description complete all as specified and directed. Note:- Reinforcement shall be measured and paid separately under respective items of this BOQ
PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channel and drain including necessary use and waste of form work and demolition of existing old cement concrete of any description complete all as specified and directed.
Extra for forming fair finished drain or channel not ex 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed.
PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in coping, benching, holdfast etc including weathering sliglitely rounded or chamfered including necessary use and waste of form work including demolition of existing old cement concrete (unreinforced) of any description and in any position for complete all as specified and directed.
15mm bore short body bib tap chromium plated with wall flange and aerator fixed in repair complete all as specified and directed. Make- Jaguar ESSCO cat part No SQT-511KN or equivalent of Cera/Hindware
15mm dia Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed in repair. (Minimum weight 15mm-90gms/20mm125gms). complete all as specified and directed.
15mm bore stop valves Male/Female end chromium plated fixed in repair complete all as specified and directed. Make- Jaguar ESSCO cat part No SQT-513BKN/513/ AKN or equivalent of Cera/Hindware
1000 Litres capacity rotational moulded polyethylene water storage tanks, three layered, ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including 20mm dia GI light grade washout pipe 50mm long with plug and 20mm dia GI light grade over flow pipe 600mm long with fitting including dismantling of existing unserviceable tank and removing from site complete all as specified and directed.
Preparing surfaces holding the members in true position and welding in reparis n. exc 2.5 cm in length, thickness of metal to be welded exc 6 mm but n. exc 9 mm complete all as directed.
Hacking out old broken glass pane of any thickness and size from wooden/metal frame including punching or drilling and glazing pins etc complete all as directed.
3mm thick sheet glass ordinary quality type & glazing with wooden beads in squares not exc 0.5 Sqm in each pan, complete all as directed.
2nd class hard wood scantling clean swan 40 sqcm and over in section fixed with nails in framed work in any position including dismantling existing timber scantling complete all as specified and directed.
Removing /cutting trees vegetation, digging out roots filling holes on building wall/roof/cajja etc and making good with cement mortar 1:3 or cement concrete 1:2:4 type B-1 including removal of material to a distance exc 250m not exc 500m complete all as specified and directed.
Repairing to existing door/ window chajjas upto 3.0m span and width 1.0m by demolition/ scrapping of damaged portion and preparing the surfaces by providing 50mm thick cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate including finishing the surface by rendering 10 mm thick plaster in CM 1:3 and finished even and smooth surface using extra cement over concrete surface and PCC benching including weathering sliglitely rounded or chamfered angles and throating complete all as specified and directed (work to be carried upto a height of 7.5m)
Taking down existing broken portion of upward / inverted facia or roof slab or visible concrete rienorcement of any thickness and surface area exc 0.5 sqm but not exc 5.0 sqm and providing cement concrete (1:2:4) type B-1 using 12.5 mm granded stone agg including finishing the surface by providing 10mm thick rendering in CM 1:3 and finish the surface smooth using extra cement over concrete surface and PCC benching including weathering sliglitely rounded or chamfered angles and throating all as specified and directed (work to be carried upto a height of 7.5m) .
4mm thick E-board false ceiling (Classic) including galvanised colour coated snap grid frame for false ceiling, size of grid 605 X 605mm fixed with 1.6 mm dia GI wire suspenders one end tied to roof members and other end connected to main tee of grid framework by means of 4mm dia adjustable "J" hook consisting of two Nos washers and two nuts at 1.2 mtr centres, size of main tee 38mm X 25mmX 1.4mm, cross tee 38 mm X 25 mm X 1.4mm, angle along walls 38 mm X 25mm X 2.0 mm and including taking down existing boards any thickness including cover fillets etc complete all as directed
4 mm thick cement plain building boards fixed in ceiling to timber framework with screws including all accessaries with and including two coats of white wash including dismantling existing boards and including cover fillet complete all etc complete all as specified and directed.
Preparation of old plastered surfaces of wall ceiling by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of Appex paint (Weather coat exterior paint) complete all as specified and directed. Note:- Work to be carriedout upto hight of 7.5 m
Preparation of new plastered surfaces of wall and applying two coats of snowcem (cement base paint) complete all as directed.
Disconnecting existing tank of any description, setting aside (or lowering if required) for cleaning and removing all Scale dirt etc and from mouths of circulating pipes including washing with bleaching powder etc and hosting, reconnecting and re fixing in position of capacity exc 250 ltr but n exc 500 ltr complete all as specified and directed.
ACE BUILDERS AND CONTRACTORS
VERDHMAN ASSOCIATES
Sharda Enterprises
sweety pest control
M/s RK ENTERPRISES
Aron Water Proofing and Pest Control
Meher enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .