Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.7 L+₹2.6 L (10.4%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹27.9 L+₹2.8 L (11.4%)Rejected-Finance D NO 9 2 1 1 VUDA QUATERS PITHAPURAM COLONY VISAKHAPATNAM PIN 530 003 | VISAKHAPATANAM | ANDHRA PRADESH | 530003 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹28.0 L+₹2.9 L (11.6%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹28.4 L+₹3.3 L (13.3%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
10 Mar 2022, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINT OF STREET/SECURITY LIGHTS, POST TOP LANTERNS, HIGH MAST LIGHTS, GARDEN LIGHTS AND REPAIR/MAINTENANCE OF DG SETS AT INS DEGA UNDER AGE E/M NO-II OF GE(U-I), VISAKHAPATNAM
2022_MES_505905_1
8387/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Utility-I Visakhapatnam
Class D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-I
₹94,000
Yes
23 Mar 2022
4 Feb 2022
11 Mar 2022
4 Feb 2022
10 Mar 2022
19 Feb 2022
Amount
Excavation in trenches n.exc 1.5m wide and not exc 1.5m depth and getting out in soft and loose soil all as directed.
Returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Removal of surplus excavated material of any type to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5 m bove the starting point complete all as specified and directed.
M&L for sand cushioning / sand covering for underground cable protection complete all as specified. Note: Punned thickness shall only be measured and paid.
Supply and laying sub class 'B' bricks of old size (approved size locally available) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
M&L for GI pipe light grade 50 mm dia laid along road crossings / plinth protection with suitable fittings for cable protection or fixed to the pole/ Wall complete all as specified and directed by Engineer-in-Charge . Make : Surya Roshni Ltd / Tata / Jindal steel / Prakash
supply and fix in replacement Electronic Timer suitable for street light timer panel/DG AMF panel/ Star Delta Starter panel complete all as specified and directed by Engineer-in-Charge . Make: L&T/ Indoasian/GE/BCH.
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like ballast, lamp, igniters, capacitors, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items herein under this Schedule.b) Necessary tools like ladders & other T&P reuired etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
All as per item No 08 here in before but upto height 5.0 Mtrs
Supply only the following spares suitable for street light / food light / post top lantern light fittings of Make: GE / Havells /CG /Goldwyn /Bajaj /Philips /Surya
Electronic driver suitable for 120 to 150 W LED light fitting
Electronic driver suitable for 90 to 100 W LED light fitting
Electronic driver suitable for 70 to 80 W LED light fitting
Surge protection device of capacity 10 KV suitable for LED light fitting
Dismantling LED light fitting of of Make: GE/Havells/CG/ Goldwyn/Bajaj /Philips /Surya of capacity 120 to 150 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of of Make: GE/Havells/CG/ Goldwyn/Bajaj /Philips /Surya of capacity 90 to 100 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of of Make: GE/Havells/CG/ Goldwyn/Bajaj /Philips /Surya of capacity 70 to 80 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV including necessary clamps etc complete and testing on completion all as specified and as directed. (Make: Havells / Philips/Bajaj/Wipro/GE ). Note: The GI pipe bracket if required will be measured and paid separately under relevant items
Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 8500 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV including necessary clamps etc complete and testing on completion all as specified and as directed. (Make: Havells/ Philips/Bajaj/Wipro/GE ). Note: The GI pipe bracket if required will be measured and paid separately under relevant items
Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV including necessary clamps etc complete and testing on completion all as specified and as directed. (Make: Havells/ Philips/Bajaj/Wipro/GE). Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV including necessary clamps etc complete and testing on completion all as specified and as directed. (Make: Havells / Philips/Bajaj/Wipro/GE ). Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Dismantling old unserviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) with ingress protection IP 65 and surge protection device of 10 KV capacity etc including necessary angle iron supports , clamps etc complete and testing on completion all as specified and as directed (Make: Havells/ Philips/Bajaj/Wipro/GE/CG ).
Dismantling old un-serviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed. (Make: Havells/Philips/Bajaj/Wipro/GE/CG ).
Dismantling old un-serviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame, with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt with ingress protection IP 66 with and including SPD of capacity 10 KV complete with necessary connection and testing on completion including taking down of existing conventional light fitting of any wattage type and size complete all as specified and as directed. (Make : Philips / Bajaj Havells / Wipro / GE.)
Taking down old unserviceable post top lantern fittings and Supply & fixing post top luminarie LED type of 40 W with IP 65 protection with die cast aluminium graphite grey powder coated finished body , polycarbonate opal diffuser, low power warm white (WW) LEDs with better heat dissipation, high efficient constant current electronic driver having operating voltage range from 140 to 280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 10 KV etc complete suitable for 60 mm OD pipe entry including suitable size loop in loop out boxes & flexible 3 core 1.5 Sqmm copper connecting cable from loop in loop out box to fitting etc complete all as specified & directed. (Make: CG/ Philips /Bajaj /Wipro /GE /Havells ). Note: The GI pipe if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable post top lantern fittings and Supply & fixing post top luminarie LED type of 60 W with IP 65 protection with die cast aluminium graphite grey powder coated finished body , polycarbonate opal diffuser, low power warm white (WW) LEDs with better heat dissipation, high efficient constant current electronic driver having operating voltage range from 140 to 280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 10 KV etc complete suitable for 60 mm OD pipe entry including suitable size loop in loop out boxes & flexible 3 core 1.5 Sqmm copper connecting cable from loop in loop out box to fitting etc complete all as directed & specified. (Make: Philips /Bajaj /Wipro /GE /Havells ). Note: The GI pipe if required will be measured and paid separately under relevant schedule items
Supplying, laying, testing and commissioning LT XLPE insulated , armoured heavy duty electric cable of following sizes, 1100 volts grade with stranded aluminium conductor laid in trenches / passing through pipe / duct/ road crossing /fixed on poles / walls Complete all as specified and directed. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex [Note: The rate quoted shall inclusive of termination at ends with suitable aluminium lugs where required]
25 Sqmm 3.5 Core
16 Sqmm 4 core
10 Sqmm 4 core
Supply and erection, testing and commissioning of Hot dip galvanised octagonal pole of 7.5 m height, top dia 70 mm bottom dia 135 mm, Base plate 225mm x 225 mm x 16 mm, foundation bolt M20 x 700 - 04 Nos complete with single arm GI bracket of suitable size and including built in connecter control box with locking arrangement along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box and flexible 3 core 1.5 Sqmm copper connecting cable from control box to fitting all as directed including dismantling old one complete all as specified and directed. ( Make: C&N / Utkarsh / GE or Equivalent ). Note: The rate quoted shall be inclusive of the following: (a) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates & templates- complete set. (b) Construction of suitable shallow foundation with M-20 grade concrete for the pole considering the safe soil bearing capacity at site as 10 t/m² at 2 m depth with all material and labour as per manufacturer design. (c) Erection and commissioning of the octagonal pole with the help of suitable equipment.
S&F in repair PVC insulated 3 core 1.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting testing and commissioning all as directed. Make: Plaza/ Gloster/Polycab/Havells.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Supply and fixing timelite distribution boards (street light DBs) 65 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one . Make: Indo Asian/ HPL/Havells
S&F loop-in/loop-out box of internal size 200x160x98 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed.
M&L for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.
M&L for preparation of old painted steel surfaces of 9 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with 125 mm dia adhesive sticker with white letters/ blackground etc complete all as directed
M&L for preparation of old painted steel surfaces of 5 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with 125 mm dia adhesive sticker with white letters/ blackground etc complete all as directed
M&L for fixing in repair adhesive sticker radium type red coloured water resistant of approx 2 inches width around the circumference of pole at a approx height of two meters all as directed.
M&L for Alternators warm up, cleaning the dust with dry blow air, megger the insulation values , measure the load / no load excitation voltages before & after maintenance and record the values all as dircted by Engr-in-Charge of following capacity:-
(a) 320 KVA DG set
(b) 250 KVA DG set
(c) 160/200 KVA DG set
(d) 100/125 KVA DG set
(e) 62.5/63/82.5 KVA DG set
(f) 30/40 KVA DG set
M&L for dismantling the upper & lower tank of radiator and replace the copper radiator core pipe including testing and painting complete all as specified and directed for the following capacities :-
(a) 320 KVA DG set
(b) 160/200/250 KVA DG set
(c) 100/125 KVA DG set
(d) 62.5/63/82.5 KVA DG set
(e) 30/40 KVA DG set
M&L for De-scaling of radiator by dismantling the upper & lower tank and cleaning the core pipes with cleaning chemicals (radi wash), components and arrest the leaking core by brazing/ dummy with lead including cleaning of upper and lower tanks and replacing the upper and lower gaskets and required nuts, bolts, refixing the same including testing and painting complete all as specified and directed for the following capacities :-
(a) 625 KVA DG set
(b) 320 KVA DG set
(c) 250 KVA DG set
(d) 160/200 KVA DG set
(e) 100/125 KVA DG set
(f) 62.5/63/82.5 KVA DG set
(g) 30/40 KVA DG set
M&L for preparation of old painted steel surfaces of following capacity DG sets including alternator, radiator support channels complete, connected equipments complete and painting with two coats of approved colour synthetic enamel paint complete all as directed. Note:-1. Painting should be done with existing colour codes and painting should apply with the help of spary gun using air compressor. 2. Quotated rate shall deemed to be included for preparation of old painted surface by twinkering and applying zinc chrome primer over twinkered/rusted portion all as directed.
(a) 320 KVA DG set
(b) 250 KVA DG set
(c) 160/200 KVA DG set
(d) 100/125 KVA DG set
(e) 62.5/63/82.5 KVA DG set
(f) 30/40 KVA DG set
Cleaning of diesel tank of any capacity carefully by drining out fuel in the tank including disconnection from fuel system, descaling the diesel tank with water pressure and removing the complete sludge deposited, drying the tank, repair to any leakage, cleaning and testing of fuel line upto Fuel Pump inlet all as directed for the following capacities :-
(a) 625 KVA DG set
(b) 320 KVA DG set
(c) 250 KVA DG set
(d) 160/200 KVA DG set
(e) 100/125 KVA DG set
(f) 62.5/63/82.5 KVA DG set
(g) 30/40 KVA DG set
M&L for fixing of View Glass with beading in canopy all as dircted by Engr-in-Charge of following capacity:-
(a) 320 KVA DG set
(b) 250 KVA DG set
(c) 160/200 KVA DG set
(d) 100/125 KVA DG set
(e) 62.5/63/82.5 KVA DG set
(f) 30/40 KVA DG set
M & L for Replacement of complete water hose pipe set including clips,nuts, bolts and washers etc of the DG Set all as specified and dircted by Engr-in-Charge of following capacity:-
(a) 320 KVA DG set
(b) 160/200/250 KVA DG set
(c) 100/125 KVA DG set
(d) 62.5/63/82.5 KVA DG set
(e) 30/40 KVA DG set
M & L for replacement of complete fuel and lub oil hose pipe set with clamp / clip etc of the following capacity of DG sets:-
(a) 320 KVA DG set
(b) 160/200/250 KVA DG set
(c) 100/125 KVA DG set
(d) 62.5/63/82.5 KVA DG set
(e) 30/40 KVA DG set
M&L for replacement of herness wiring complete all as directed for the following capacity of DG sets:-
(a) 320 KVA DG set
(b) 160/200/250 KVA DG set
(c) 100/125 KVA DG set
(d) 62.5/63/82.5 KVA DG set
(e) 30/40 KVA DG set
M&L for pump & injectors calibration of the DG Set all as specified and dircted by Engr-in-Charge of following capacity:-
(a) 320 KVA DG set
(b) 250 KVA DG set
(c) 160/200 KVA DG set
(d) 100/125 KVA DG set
(e) 62.5/63/82.5 KVA DG set
(f) 30/40 KVA DG set
M&L fixing of for PVC covered iron mesh at fresh air inlet to avoid entry of snakes , lizards etc.all as dircted by Engr-in-Charge of following capacity:-
(a) 320 KVA DG set
(b) 250 KVA DG set
(c) 160/200 KVA DG set
(d) 100/125 KVA DG set
(e) 62.5/63/82.5 KVA DG set
(f) 30/40 KVA DG set
M & L for replacement of battery lead set of 2 Nos 1.5 mtr long copper lead of 35 Sqmm size including GM terminals at one end and coper lug at other end all as directed
M&L for repair and servicing of self starters including replacement / rewinding of armature, carbon brush set with holder, king pin holder, check nut, body screens, clutch plate assembly and solenoid switch etc all as directed for the following capacity of DG sets :-
(a) 320 KVA DG set
(b) 160/200/250 KVA DG set
(c) 100/125 KVA DG set
(d) 62.5/63/82.5 KVA DG set
(e) 30/40 KVA DG set
Supply and toping up of engine oil 15W40 or as per manufacturers recommendations for topping up or replacement. Make: Castrol/Servo/HPCL
Supply and toping up of radiator coolents as per the rcommendation of engine manufacturer all as directed.
M&L for carrying out 'B' check for DG set 625 KVA, as per manufacturer's recommendation including replacement of fuel filters,air filters and oil filters, 'O' rings, engine oil, gasket, coolant etc complete. Make of Engine: Greaves Cotton
M&L for carrying out 'B' check for DG set 320 KVA, as per manufacturer's recommendation including replacement of fuel filters,air filters and oil filters, 'O' rings, engine oil, gasket, coolant etc complete. Make of Engine: Greaves Cotton
M&L for carrying out 'B' check for DG set200/250 KVA, as per manufacturer's recommendation including replacement of fuel filters,air filters and oil filters, 'O' rings, engine oil, gasket, coolant etc complete. Make of Engine: Greaves Cotton/Ashok Leyland
M&L for carrying out 'B' check for DG set 160 KVA, as per manufacturer's recommendation including replacement of fuel filters,air filters and oil filters, 'O' rings, engine oil, gasket, coolant etc complete. Make of Engine: CUMMINS
M&L for carrying out 'B' check for DG set 100/125 KVA, as per manufacturer's recommendation including replacement of fuel filters,air filters and oil filters, 'O' rings, engine oil, gasket, coolant etc complete. Make of Engine: CUMMINS
M&L for carrying out 'B' check for DG set 82.5 KVA, as per manufacturer's recommendation including replacement of fuel filters,air filters and oil filters, 'O' rings, engine oil, gasket, coolant etc complete. Make of Engine: Kirloskar/ CUMMINS
M&L for carrying out 'B' check for DG set 62.5/63 KVA, as per manufacturer's recommendation including replacement of fuel filters,air filters and oil filters, 'O' rings, engine oil, gasket, coolant etc complete. Make of Engine: Kirloskar/ CUMMINS
M&L for carrying out 'B' check for DG set 30/40 KVA, as per manufacturer's recommendation including replacement of fuel filters,air filters and oil filters, 'O' rings, engine oil, gasket, coolant etc complete. Make of Engine: Kirloskar/ CUMMINS
Disconnecting and removing existing unserviceable battery and S&F maintenance free battery 12V 100 AH with minimum 2 years warrenty all as specified and as directed by Engineer-in-Charge. [Make: Exide/ Amco/Amron]
Disconnecting and removing existing unserviceable battery and S&F maintenance free battery 12V 180 AH with minimum 2 years warrenty all as specified and as directed by Engineer-in-Charge. [Make: Exide/ Amco/Amron]
Checking complete wiring for AMF panel and identifying fault in the safety and control system wiring from AMF panel to engine control gadgets like HWT. LLOP, and shut down valve, dynamo self-starter etc for 250/320 KVA DG set engine and rectifying fault in the AMF system including replacement of EC-2 Relay,suitable capacity of contactor, burnt control wiring cable with thimbles and ferrules, blown out fuses for proper fuctioning and testing the DG set all as directed
Checking complete wiring for AMF panel and identifying fault in the safety and control system wiring from AMF panel to engine control gadgets like HWT. LLOP, and shut down valve, dynamo self-starter etc for 160/200 KVA DG set engine and rectifying fault in the AMF system including replacement of EC-2 Relay, suitable capacity of contactor,burnt control wiring cable with thimbles and ferrules, blown out fuses for proper fuctioning and testing the DG set all as directed
Checking complete wiring for AMF panel and identifying fault in the safety and control system wiring from AMF panel to engine control gadgets like HWT. LLOP, and shut down valve, dynamo self-starter etc for up to 125 KVA DG set engine and rectifying fault in the AMF system including replacement of suitable capacity of contactor, burnt control wiring cable with thimbles and ferrules, blown out fuses for proper fuctioning and testing the DG set all as directed
S&F in repair AVR with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator droop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set intial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max upto 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG sets of capacity 30 KVA to 82.5 KVA
S&F in repair AVR with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator droop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set intial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max upto 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG sets of capacity 100 KVA to 320 KVA
S&F in repair microprocessor based integrated power command controller for DG set monitoring and metering protection and contrioll system with built in torque matched volts/Hz over load controll preferably the gen set function including (i) Digital governing (ii) Digital voltage controll (iii) Digital engine controll (iv) operator interface (v) protection parametres i.e RPM, Battery Voltage, lub oil pressure failure, coolent temperature, running hour, high water temperature, high/low dc voltage, weak batery,over speed fai to crank , fail to start senser (vi) advanvce controll function (vii) alternate protection shold be under voltage , over voltage, over current, under/over frequency, loss of sensing including necessary control wiring complete , testing & commissioning for DG sets of capacity 30 KVA to 82.5 KVA
S&F in repair microprocessor based integrated power command controller for DG set monitoring and metering protection and contrioll system with built in torque matched volts/Hz over load controll preferably the gen set function including (i) Digital governing (ii) Digital voltage controll (iii) Digital engine controll (iv) operator interface (v) protection parametres i.e RPM, Battery Voltage, lub oil pressure failure, coolent temperature, running hour, high water temperature, high/low dc voltage, weak batery,over speed fai to crank , fail to start senser (vi) advanvce controll function (vii) alternate protection shold be under voltage , over voltage, over current, under/over frequency, loss of sensing including necessary control wiring complete , testing & commissioning for DG sets of capacity 100 KVA to 320 KVA
Taking down old unserviceable landscape light fittings and Supply & fixing landscape light fittings LED bollard type, 10 W with IP 65 protection with die cast aluminium mat black powder coated finished body , inverted pyramid tripod type with soft 360 deg light distribution including suitable fixing arrangement, connecting and commissioning complete all as directed & specified. MAKE : Philips / Havells / Wipro / GE / Bajaj [ Note: The earth work and PCC work shall be included in the quoted rate ].
M&L for Dismantling and shifting of existing steel tubular pole of 8.5m / 9.0m long to another site with in 1 KM range complete all as directed. ( NOTE: (i) The rate quoted shall include for dismantling of existing concrete and required earth work to taking down pole and necessary T&P required to transport same to new location. (ii) Required earth work at new location, PCC foundation, Coping shall be measured and paid separately )
M&L for PCC type C2, 1:3:6 using (40 mm gradded stone aggregate) in foundations complete all as specified &directed.
M&L for PCC 1:2:4 type B1 with 20 mm graded aggregate for coping of poles and stay including form work complete all as specified and directed.
GS ENGINEERS
ALPHA ENGINEERING CONSTRUCTIONS
MVV Prasad
SAI ENGINEERING WORKS
ANJALI ENTERPRISES
HUSSAIN ENGINEERING WORKS
M/S EVEREST INFRA
M/s KRK Raju Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .