Loading…
Loading…
Tender Value
₹15.8 L
EMD Value
₹15,800
Closing Date
18 May 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Executive Engineer, Electrical (R&B) Division, surat
Providing Passenger Lift (01 Nos) in Taluka Court Building at Valod Dist. Tapi
301788
Online Tender Notice No. 02 of 2026-27 (Third Attempt)
Open
Electrical Works
Surat
12 documents required · 12 mandatory
₹900
Executive Engineer, Electrical (Rand B) Division, Surat.
₹15,800
5 May 2026
5 May 2026
5 May 2026
18 May 2026
5 May 2026
Name Of Work : Providing Passanger lifts (01 No.) in Taluka Court Building at Valod, Ta. Vaod, dist. Tapi
Qty. Unit Item Per Amount
In Figure In Words
1 Nos. 1 Supplying, Erecting, Testing & 1575617.17 Rupees Fifteen Nos
Commissioning the passenger / stretcher lift Lakh(s) Seventy .
having following main features: Five Thousand
Paise Seventeen
[1] GEAR LESS LIFT DRIVE (MRL)
comprising of High Starting torque Lift
phase 440 V A. C. Permanent Magnet
Synchronous motor of proper rating with
high efficiency shall be used.[2] Micro
processor based / PLC, ACVVVF, vector
control drive with encoder feedback closed
loop system shall be used for lift car and
door operation which shall be full collective
selective operation hall call demand
response, UP/DOWN hall stops, Main, Up/
Down Contactor with overload and phase
reversal relay and safety controls.
[3] Car with M S platform with bracings of
adequate size and to sustain the impact load
cabin + passenger with safety factor of fire
for steel and side panels of Stainless steel of
sheet of grade 304 duty. Car ceiling will be
S.S. finishes with aesthetic appearance with
LED ceiling lights. Car flooring shall be of s/s
304 chaker plate design sugeested of
engineer in charge. of engineer in charge. Car
doors shall be of stainless steel grade
hairline finish with centre opening /
telescopic automatic doors. Car panel will
also be S.S. 304 finished with emergency
stop device, mechanical door safety device,
facility of auto/ attended mode. All car panel
buttons and all floor switches must be with
brail language as per lift act..
blank schedule-b Fast Track lift (2) Page 1 of
Qty. Unit Item Per Amount
In Figure In Words
[4] All landing doors must be fire rated for
hour shall be fully automatic centre opening/
telescopic opening made of hairline finish
steel grade of 304 with key holes and
infrared curtains with Unlocking facility
[5] Appropriate battery operated emergency
light in the car along with alarm switch shall
be provided. Also, Emergency Light & Fan
should start immediately without any Time
Delay as soon as power fails.
[6] Digital scrolling indicator system for up-
down arrow along with floor position
indicator shall be provided inside the car
and at all floors.
[7] Full height infra red curtain with multiple
cross / crossing light beams shall be
[8] Automatic Rescue Device (ARD) shall be
provided accordingly of passenger capacity
with Manual Rescue Operation ( Manual
Cranking Facility).
[9] Audio visual indication in the lift car
showing over loading shall be provided such
that doors kept open till excess load is
[10] Spring buffers/PU Buffers shall be
[11] Car fan as per passenger capacity with
automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music
shall be provided in lift car.
[13] Self diagnostics system for operational
and safety parameters shall be provided in
[14] Mechanical over speed governor with
governor calibration as per actual site
parameters and submission of calibration
certificate submission, door key holes in the
floor doors, fireman switch shall be
[15] Lift machine hoisting arrangement in
the lift machine room and monkey ladder for
lift pit should be provided by the lift agency,
along with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be
provided without any extra cost, where ever
required as / if directed by engineer in
blank schedule-b Fast Track lift (2) Page 2 of
Qty. Unit Item Per Amount
In Figure In Words
[10] Spring buffers/PU Buffers shall be
[11] Car fan as per passenger capacity with
automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music
shall be provided in lift car.
[13] Self diagnostics system for operational
and safety parameters shall be provided in
[14] Mechanical over speed governor with
governor calibration as per actual site
parameters and submission of calibration
certificate submission, door key holes in the
floor doors, fireman switch shall be
[15] Lift machine hoisting arrangement in
the lift machine room and monkey ladder for
lift pit should be provided by the lift agency,
along with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be
provided without any extra cost, where ever
required as / if directed by engineer in
[17] Permanent wiring with necessary safety
devices like RCCB in all circuit, Over Voltage
Under Voltage protection and THD
eliminator in circuit for lift machine room
and lift well with proper numbers of light
points, with fixtures, exhaust fan and plug
points shall be provided by the agency. Only
3 phase Power Supply shall be made
available by department in lift machine
room. Necessary Earthing as per Lift
Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for
additional and alteration in lift shaft and
machine room related to erection of lift shall
be made by lift agency without any extra
cost. (granite/marble fixing around all
landing door openings are not in lift
agency’s scope.)
[19] Agency has to provide all working
drawings and documents and liaison
services for obtaining all necessary
permission from lift inspector and other
authorities. [20] acrylic transparent
licence/display A4 size holder in lift cararent
licence/display A4 size holder in lift car
blank schedule-b Fast Track lift (2) Page 3 of
Qty. Unit Item Per Amount
In Figure In Words
[20A] As per statutory requirement of Govt.
Of Gujarat lift & escalator act 2000, lift
agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground
4.carrying out third party lift inspection
during/after lift erection and provide report
by third party authorized by concern
licensing authority 5.agency has to provide
third party insurance upto completion of
free maintenance period and submit the
document for the same.
[21] Car Panel Operating Buttons with floor
position indicator/buttons must be of Auto
Glow type clearly visible when view from
[22] For Physically Handicapped person Full
Length Handrails of hairline finish steel
grade of 304 should be provided at
appropriate height on the Rear & Side Wall
Panels in Lift Car. [23] With Necessary KVA
rating voltage controlled Stabilizer suitable
for your controller, drive and all equipments
[24] Necessary rating of DP Elcb and FP Elcb
required for lift is in scope of work which
rating is sugested by CEICED Department
(electrical Inspector)
(B) SPECIAL FEATURES DESCRIPTION OF
LIFTS for PREMIUM category
1. Advanced control system dual 64 bit
embedded microprocessor with CANBUS
Serial Communication mode including
Regenerative power efficient operation,on
site programming facility, Anti nuisance, Pte-
opening, BMS/RMS with necessary online
real time monitoring system having
necessary connectivity for remote
monitoring & other suitable supporting
hardware & software devices to fulfil the
2. Floor Indication LCD Display with call
registration & brail mark with arrival gong
and hall lantern & TFT Screen in the car with
MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive SS
Moonrock finish / Hair Line / Honeycomb
for car and all Doors, All landing doors must
have fire rating up to 2 hours and car door
must have multi-level crisscross beam door
4. To & fro communication system & wiring
(i.e. car , control room & guard room ) and
Each elevator are equipped with remote
monitoring system.agency has to provide
mobile app and user id and password for
blank schedule-b Fast Track lift (2) Page 4 of
Qty. Unit Item Per Amount
In Figure In Words
8/10 Passengers, Ground plus 3 upper floor
with Rated Speed of 1.0 m/sec.(C) With
General PLUS ADDITIONAL SPECIAL
FEATURES attached herewith. Prem. Cat.
Deputy Executive Engineer Executive Engineer
Electrical (R &B) Sub Division, Electrical (R &B) Division,
Total Rs. In Words
I am / We are willing to carry out the work at _ _ ___ ___% below ___________________________
___________________________________% (Should be written in figure and words) of the estimate rates mentioned above. Amount
of my/our tender work out as under.:
(A)Total Tendered Amount. Rs.__________________
(B) Rebate on above tender amount (if any)___________% (In Figure) Rs.__________________
(C) Net Tendered Amount ( A-B) Rs.__________________
(a) I/We hereby declare that I/We have visited the site and fully exquisite myself/ourselves with the
local situation regarding materials, labour and other factors pertaining to work before submitting tender.
(b) I/We hereby declare that I/We have carefully studied the conditions of contracts, Detailed
specification and other tender document of this work and agree to execute the same accordingly.
Note 1) The Rates are inclusive of all taxes, transport charges, GST and storage charges upto date.
2) The materials covered under contract should be got approved from the Dy. Executive Engineer, in charge of the
3) The materials and work shall have to be used and carried out as specification in technical note.
4) All works shall be carried out as per public works Department hand book and Other specifications of the Dn. Or
5) Rates are inclusve of 1% Labour cess in tender amount so 1% of total amount of bill will be deducted from the
5) Rates are inclusve of 1% Labour cess in tender amount so 1% of total amount of bill will be deducted from the
6) The material to be used in this work should be approved strictly from Engineer-in-charge / Deputy Ex.
Engineer as applicable.
7) The agency will have to agree to carried out the work as per brand demand of concern deptt.
(Signature of Contractor)
blank schedule-b Fast Track lift (2) Page 5 of
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Schedule B For Lift Valod.pdf
Pre – Qualification (Eligibility) Criteria of Bidders.pdf
AMC FOR LIFT FOR 15 YEARS.pdf
Annexure – I.pdf
Annexure – II.pdf
Annexure – III.pdf
Annexure – IV.pdf
GENERAL SPECIFICAITON OF THE LIFT.pdf
Notice No 02 of 2026-27 Third Attempt.pdf
TIME SCHEDULE.pdf
Download all tender documents and submit your bid