Loading…
Tender Value
₹1.8 Cr
EMD Value
₹3.6 L
Closing Date
2 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS 2
14 conditions · 3 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less; Where V=Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Electrical contractor license: - The contractor should have valid electrical contractor license issued by government and submit along with tender document. If valid electrical contractor license is not submitted along with tender document, then offer will be summarily rejected.
Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. The Definition of similar nature in this tender means "Any Electrical work related to HT/LT installations". (Authority: PCEE / NWR / JP letter No EL/50/0/SNW/Vol.I Dtd. 08.01.2016).
3 conditions · 1 needing a document upload
Bidder / Tenderer should submit GST registration certificate along with PAN card & Bank mandate while bidding / uploading tender documents
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I / We have visited the works site and I / We am / are aware of the site conditions.
Provision of Air conditioners at all branches in DRM office and strengthening of power supply system at DRM office and other associated locations.
50R2of2025-26~NWR
50R2of2025-26
Open
Works - General
12 Months
Jodhpur, Rajasthan
₹0
₹3.6 L
11 Aug 2026
11 Aug 2026
19 Aug 2026
123 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,81,27,925.66 | ||
| — | 1.00 | — | — | ||
| a)Supply, installation, testing & commissioning of complete unipack CSS 1 of with 01 no. 11 KV 1000KVA dry type transformer, HT switchgear with 03 VCB arrangement (01 I/C + 02 O/G), GI enclosure and LT distribution board with tie feeder as per specification. b) Supply, installation, testing & commissioning of complete uni pack CSS 2 of with 01 no. 11 KV 1000KVA dry type transformer, HT received from CSS-1, GI enclosure and LT distribution board with tie-feeder and 300 KVAR apfc panel as per specification. (Inspection: RITES, Inspection Charges: To be borne by Railways) | — | — | — | 94,81,300 | |
| — | 100.00 | — | — | ||
| Installation charges of split ACs as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 4,36,510 | |
| — | 1.00 | — | — | ||
| L.T. Panel-III Manufacturing, supplying, testing and commissioning of LT Panel with incomer 800 Amp. ACBs 1 no. and outgoing 400A MCCBs 4 nos., 250A MCCBs 4 nos & 100A MCCBs 3 nos as per specification. (Inspection: RITES, Inspection Charges: To be borne by Railways) | — | — | — | 5,57,391.67 | |
| — | 4.00 | — | — | ||
| L.T. Panel-I Manufacturing, supplying, testing and commissioning of wall/floor mounted (as per site requirement) LT Distribution board with 01 No. 200 Amp. 4 pole 415 Volt, 50 Hz, thermal magnetic MCCB as incoming and 02 No.100 Amp. 4 pole MCCB, 03 Nos. 40 Amp. 4 pole MCCB as outgoing. .(As per Specification attached) (Inspection: Consignee, Inspection Charges: None) | — | — | — | 4,74,426.96 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of automatic power factor correction control panel with 100KVAR shunt capacitors as per list of material and specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,42,640.56 | |
| — | 16.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated Feeder Pillar distribution box made of MS sheet 1.6mmthick size 600x300x600mmwith suitable MS stand Copper bus bar of 200Acapacity and 2x63A MCB 4pole as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 93,450.24 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing & commissioning of VTPN typemetal double door type 8 way DB with having 01 No. 250 Amp., 4 pole MCCB, 36 KA as incomer & 8 Nos. TP MCB, 10KA'C' curves, 40-63 Amp. Cap. As outgoing having suitable IP-54,IK-09protection. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,13,400.6 | |
| — | 3500.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec ( trench work may be on kuchcha/ pucca land and all type of soil as per site requirement and without protective layer of brick). Surface of trench shall be made good in all respect and satisfaction of site engineer. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,42,415 | |
| — | 2000.00 | — | — | ||
| laying cable in Air/Wall/Pole with fixture(02 nos. per mtrs) as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 48,640 | |
| — | 100.00 | — | — | ||
| Supplying., laying of GI pipe size 50 mm dia. B class as per IS1239 for cable use as per specification enclosed (Inspection: Consignee, Inspection Charges: None) | — | — | — | 34,426 | |
| — | 150.00 | — | — | ||
| Supplying., laying of GI pipe size 100 mm dia. B class as per IS1239 for cable use as per specification enclosed (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,01,259 | |
| — | 3000.00 | — | — | ||
| Supply & laying of HDPE pipe of 75/80mm dia, wall thickness3mm. The work involves laying of HDPE pipe & laying cable in HDPE pipe. As per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,08,340 | |
| — | 1000.00 | — | — | ||
| Drilling of horizontal bore below track/road by pushing method for laying of RCC/HDPE/DWC pipe of various sizes (As per specifications) (Inspection: Consignee, Inspection Charges: None) | — | — | — | 14,24,400 | |
| — | 900.00 | — | — | ||
| Supply & laying of HDPE pipe, dia 160 mm under road/ground/floor/railway track or as per site requirement in already excavated trench. (As per specification) (Inspection: RITES, Inspection Charges: To be borne by Railways) | — | — | — | 7,11,144 | |
| — | 1000.00 | — | — | ||
| Laying, connecting & commissioning of cable in pipe/trench etc. with complete lug, glands & transportation of cable etc. as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,42,110 | |
| — | 20.00 | — | — | ||
| J' type cable route marker made of cast iron as per approved Railway drawing. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 4,346.4 | |
| — | 3200.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x6 sq mm PVC insulated multi-strand ( 84 /.30 mm ) copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 4,01,984 | |
| — | 1000.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x4 sq mm PVC insulated multi-strand ( 56 /0.3 mm ) copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm as per specifications attached as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 88,900 | |
| — | 200.00 | — | — | ||
| Wiring of main (for individual qtr.) with 2x4 sq mm 56/.30 PVC insulated multi-strand copper cable in 19/20 mm dia MS conduit pipe to be fixed properly with saddles, gutties & other fixtures and continuous running of PVC insulated copper earth wire as per specifications attached. Including supply of material as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 26,034 | |
| — | 4200.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x2.5 sq mm PVC insulated ( 36 /0.3 mm ) multi-strand copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,93,244 | |
| — | 4200.00 | — | — | ||
| Supply and Fixing of 20 mm dia medium class P.V.C. Pipe along with accessories as required in recess on walls/roof properly including cutting of wall /roof and making good the damages as per specifications attached. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,41,418 | |
| — | 400.00 | — | — | ||
| Supply and Fixing of 20 mm dia medium class PVC Pipe along with accessories as required in surface on walls/roof properly with saddles and wooden gutties etc. complete as per specifications attached. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 21,304 | |
| — | 200.00 | — | — | ||
| Supply of material & commissioning of PVC casing caping 25X12 mm with accessories for surface wiring as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 4,898 | |
| — | 240.00 | — | — | ||
| Assembling, fixing, hanging and making connection of Surface pendent mounted box type tube light fitting/street light fitting as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 16,461.6 | |
| — | 800.00 | — | — | ||
| Supply of material and wiring of LP/TP/FP/Ex. Fan point with 1.5sqmm PVC single core multi-stranded copper wire insulated concealed in stone/brick masonry wall in19/20 mm PVC conduit with 1.5sqmm PVC wire insulated copper for earth wire 1-way/2-way switch 5/6A as required and good quality ceiling rose including connection (MODULAR)as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,91,816 | |
| — | 200.00 | — | — | ||
| Supply and fixing ceiling of fan regulator electronic type 5-step as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 76,128 | |
| — | 200.00 | — | — | ||
| Supply and fixing 12 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC (Inspection: Consignee, Inspection Charges: None) | — | — | — | 50,676 | |
| — | 100.00 | — | — | ||
| Supply and fixing 8 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC (Inspection: Consignee, Inspection Charges: None) | — | — | — | 27,312 | |
| — | 80.00 | — | — | ||
| Supply and fixing 6 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC (Inspection: Consignee, Inspection Charges: None) | — | — | — | 13,967.2 | |
| — | 120.00 | — | — | ||
| Supply and fixing 4 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC (Inspection: Consignee, Inspection Charges: None) | — | — | — | 21,811.2 | |
| — | 120.00 | — | — | ||
| Supply, install, test & commission of 3Moduler metal flush box with suitable size cover &base frame as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 24,750 | |
| — | 200.00 | — | — | ||
| Supply and fixing 2 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC (Inspection: Consignee, Inspection Charges: None) | — | — | — | 23,396 | |
| — | 78.00 | — | — | ||
| Supply, fixing and connecting modular type exhaust fan 225/250mm as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 62,127.78 | |
| — | 500.00 | — | — | ||
| Supply, install, test &commission of Modular6amp, 5 Pin Socket as per specifications. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 63,055 | |
| — | 900.00 | — | — | ||
| Supply, install, test & commission of Modular 6amp one way/SP Switch, ISI marked as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 59,409 | |
| — | 518.00 | — | — | ||
| Supply, install, test & commissioning of Modular 16 amp, 3/3(6Pin) Socket as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,05,003.78 | |
| — | 516.00 | — | — | ||
| Supply, install, test &commission ofModular16 amp one way/SP Switch , 2 Modular ,ISI marked including connection / wiring on lighting switch board as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 71,760.12 | |
| — | 557.00 | — | — | ||
| Supply, install, test &commission of Modular blank plate as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 6,567.03 | |
| — | 100.00 | — | — | ||
| Supply and Fixing Re- roll plug socket 20 A with single pole 20A MCB & Re-roll plug top and as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 89,793 | |
| — | 25.00 | — | — | ||
| "B" Class 50 mm dia GI pipe earth Station with digging pit & refilling with charcoal & salt as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 34,638.25 | |
| — | 25.00 | — | — | ||
| Inspection Chamber with cover as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 9,661 | |
| — | 250.00 | — | — | ||
| Supply & laying of earth connection from earth electrode with 4 mm GI wire properly fixed on wall with wooden gutties etc. as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,932.5 | |
| — | 8.00 | — | — | ||
| Supply and providing copperplate earthing 4.0 m deep size600x600x3mm with 3.5m long G.I. "B" class pipe 38 mm for pouring water with 50 Kg charcoal and 10 Kg salt including RCC/masonry earth enclosure with pull out handle and 25x3mm copper flat earth strip 4.0mtrs long from earth pit bottom riveted to earth top. The earth value to be measured and marked on earth pit and as per specification attached. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 70,134 | |
| — | 320.00 | — | — | ||
| Supply and fixing copper earth strip 25x3 mm and as per specification attached (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,35,635.2 | |
| — | 120.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-MCB (SP-) 6-32 A (Inspection: Consignee, Inspection Charges: None) | — | — | — | 28,848 | |
| — | 20.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-RCCB - 25 A/30mA (Inspection: Consignee, Inspection Charges: None) | — | — | — | 50,690.4 | |
| — | 20.00 | — | — | ||
| Supply. fixing, testing and commissioning of SPN DB 8-way with provision of incoming MCB of 63A,IP 43/IK09, double door at suitable locations. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 51,254 | |
| — | 6.00 | — | — | ||
| Supply, Fixing, testing and commissioning of TPN DB 8-way with provision of incoming MCCB of 125A, IP43/IK09, double door at suitable locations. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 92,513.88 | |
| — | 12.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached- MCCB 4-pole 100/125A, 25 KA (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,66,606.8 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 25A,RCBOdouble pole, 30mA with Earth leakage, overload and short circuit protection as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 21,255.3 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 63A,RCBO Four pole, 30mA with Earth leakage, overload and short circuit protection as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 33,508.6 | |
| — | 4.00 | — | — | ||
| Supply. fixing, testing and commissioning of 04 pole MCCBs-250A as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 78,548.2 | |
| — | 4.00 | — | — | ||
| Supply. fixing, testing and commissioning of 04 pole MCCBs-200A as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,00,830.24 | |
| — | 4.00 | — | — | ||
| Supply. fixing, testing and commissioning of 04 pole MCCBs-63A as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 51,673.48 | |
| — | 100.00 | — | — | ||
| Supply, installation, testing & commissioning of (150 mm width x 50 mm depth x 1.6 mm thickness) perforated Hot Dipped Galvanized Iron Cable Tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections fixed with MS Angle frame duly painted of 35 mm x 5 mm thick and all hardware complete in all respect. (Inspection: Consignee, Inspection Charges: None | — | — | — | 69,999 | |
| — | 100.00 | — | — | ||
| Supply, installation, testing & commissioning of (100 mm width x 50 mm depth x 1.6 mm thickness) perforated Hot Dipped Galvanized Iron Cable Tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections fixed with MS Angle frame duly painted of 35 mm x 5 mm thick and all hardware complete in all respect (Inspection: Consignee, Inspection Charges: None) | — | — | — | 64,900 | |
| — | 100.00 | — | — | ||
| Supply of material with excavation & commission of foundation for pole/panel (C.C. Platform) etc . As per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,35,705 | |
| — | 100.00 | — | — | ||
| Supply, Testing & Fixing of wall mounted cabin fan with regulator three speed, suitable for 220- 230 volt ,50HZ AC supply .Model No-Media BW 04 of Bajaj or similar to Usha/ Crompton Greaves /Philips . (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,96,654 | |
| — | 26.00 | — | — | ||
| Supply and provide MS flat of iron size40x3mm with spacers and fixing clamps as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,832.4 | |
| — | 26.00 | — | — | ||
| Fixing of ceiling fan with clamp, hooks and down rod as per requirement and connection asper spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 4,819.62 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing and commissioning of Distribution Board double door, 3-phase and neutral with incoming 63A 4-pole MCB and outgoing 12Nos. MCB 6-32A single pole as per spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 25,269.65 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS1TO11COMPRESSED1_1.pdf
ATTACHMENT
SORTECHNICALSPEC50R2of202526
ATTACHMENT
TD50R2of25-26_1.pdf
ATTACHMENT
SORTECHSPECDRMofficeACNIT50R2of2025-26_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].