Loading…
Loading…
Tender Value
₹14.3 Cr
EMD Value
₹14.3 L
Closing Date
16 Sept 2026, 6:00 pm
Executive Engineer, Dahod (R & B) Division, Dahod
Construction of New Building for Government Science College at Limkheda Ta. Limkheda Dist. Dahod
339965
11 of 2026-27
Open
Civil Works - Buildings
Works
Dahod
3 documents required · 2 mandatory · 1 optional
₹18,000
Executive Engineer, Dahod (R&B) Division, Dahod
₹14.3 L
29 Aug 2026
29 Aug 2026
29 Aug 2026
16 Sept 2026
29 Aug 2026
New Construction Work of New Building for Government Science College Limkheda,Dist- Dahod
BILL OF QUANTITIES
Percentage Rate Tender
Item Description of Item Quantity Unit Rate In Amount
1 Excavation for foundation upto 1.5 m depth 3821.00 Cumt 125.86
including sorting out and stacking of useful
materials and disposing off the excavated stuff
upto 50 Meter lead.(A) Loose or soft soil
2 Excavation for foundation for depth from 1.5 m 1789.00 Cumt 309.04
to 3.0 m including sorting out and stacking of
useful materials and disposing off the excavated
stuff upto 50 Meter lead. (D) Soft rock not
requiring Blasting
3 Filling in foundation and plinth with sand in 435.00 Cumt 419.82
layers of 20 cm. Thickness including watering
ramming and consolidating etc. comp.
4 Filling available excavated Earth (Excluding 1814.00 Cumt 137.47
Rock) in trench plinth side of foundation . in
layer not excluding 20 cm in depth consolidation
each deposited layer by ramming and watering
5 Filling foundation and plinth with murrum or 3302.50 Cumt 273.07
selected soil in layer of 20 cm in thickness
including ramming watering and consolidating
6 Applying general insecticide pest control 2061.00 Sqmt 54.39
treatment to floors, cupboards etc including
labour materials etc. complete. Using
Imidacloprid 30.5 SCas Per IS 6313 part -II(
(0.075% concentration by mass) is
recommended 10.5ml chemical diluted with
liters of water application 0.5 litre chemical
/Sqm of surface is recommended as per I.S.
7 Providing and laying controlled cement concrete 566.23 Cumt 3861.37
M.150 and curing complete including the cost of
formwork and excluding reinforcement for
reinforced concrete work in (A) Foundations and
8 Providing and laying controlled cement concrete 787.00 Cumt 4852.04
M.250 and curing complete including the cost of
formwork and excluding reinforcement for
reinforced concrete work in (A) Foundations,
footings, and Mass concrete. footing
9 Providing and laying controlled cement concrete 59.50 Cumt 8278.97
M-250 and curing complete including the cost of
form work but excluding the cost of
reinforcement for reinforced concrete work in
(d) columns Up to Plinth level.
Item Description of Item Quantity Unit Rate In Amount
10 Providing and laying cement concrete 1:3:6 (1- 83.00 Cumt 3005.48
Cement : 3- coarse sand : 6- machine cut stone
aggregates 40 mm nominal size) and curing
complete excluding cost of formwork in (A)
Foundation and Plinth
11 Providing and laying controlled cement concrete 176.34 Cumt 8184.03
M-200 and curing complete including the cost of
form work but excluding the cost of
reinforcement for reinforced concrete work in
Columns, pillars posts and struts G.FLOOR
12 Providing and laying controlled cement concrete 66.50 Cumt 8184.03
M-200 and curing complete including the cost of
form work but excluding the cost of
reinforcement for reinforced concrete work in
Columns, pillars posts and struts F.FLOOR
13 Providing and laying controlled cement concrete 57.00 Cumt 8224.43
M-200 and curing complete including the cost of
form work but excluding the cost of
reinforcement for reinforced concrete work in
Columns, pillars posts and struts 2nd.FLOOR
14 Providing and laying controlled cement concrete 28.00 Cumt 8264.83
M-200 and curing complete including the cost of
form work but excluding the cost of
reinforcement for reinforced concrete work in
Columns, pillars posts and struts 3rd.FLOOR
15 Providing and laying controlled cement concrete 691.30 Cumt 6894.26
M-250 and curing complete including the cost of
form work but excluding the cost of
reinforcement for reinforced concrete work in
Ground & Plinth BEAMS
16 Providing and laying controlled cement concrete 271.50 Cumt 5240.54
M.150 and curing complete including the cost of
formwork and excluding reinforcement for
reinforced concrete work in (C) Plinth Slabs
17 Providing and laying controlled cement concrete 259.00 Cumt 6303.41
M.200 and curing complete including the cost of
formwork and excluding reinforcement for
reinforced concrete work in (C) Ground floor
18 Providing and laying controlled cement concrete 252.00 Cumt 6303.41
M.200 and curing complete including the cost of
formwork and excluding reinforcement for
reinforced concrete work in (C) First floor
19 Providing and laying controlled cement concrete 173.00 Cumt 6342.80
M.200 and curing complete including the cost of
formwork and excluding reinforcement for
reinforced concrete work in (C) Second floor
Item Description of Item Quantity Unit Rate In Amount
20 Providing and laying controlled cement concrete 8.00 Cumt 6383.20
M.200 and curing complete including the cost of
formwork and excluding reinforcement for
reinforced concrete work in (C) Third floor
21 Providing and laying controlled cement concrete 17.00 Cumt 6253.92
M-200 and curing etc. complete including the
cost of form work and reinforcement for
reinforced concrete work in (c) Chhajja for
22 Providing and laying controlled cement concrete 16.00 Cumt 6253.92
M-200 and curing etc. complete including the
cost of form work and reinforcement for
reinforced concrete work in (c) Chhajja for F
23 Providing and laying controlled cement concrete 11.00 Cumt 6294.32
M-200 and curing etc. complete including the
cost of form work and reinforcement for
reinforced concrete work in (c) Chhajja for S
24 Providing and laying controlled cement concrete 1.00 Cumt 6334.72
M-200 and curing etc. complete including the
cost of form work and reinforcement for
reinforced concrete work in (c) Chhajja for T
25 Providing and laying controlled cement concrete 8.50 Cumt 8794.07
M-200 and curing etc. complete including the
cost of form work and reinforcement for
reinforced concrete work in (c) Lintal for Ground
26 Providing and laying controlled cement concrete 7.50 Cumt 8794.07
M-200 and curing etc. complete including the
cost of form work and reinforcement for
reinforced concrete work in (c) Lintal for F floor
27 Providing and laying controlled cement concrete 6.00 Cumt 8834.47
M-200 and curing etc. complete including the
cost of form work and reinforcement for
reinforced concrete work in (c) Lintal for S floor
28 Providing and laying controlled cement concrete 1.00 Cumt 8874.87
M-200 and curing etc. complete including the
cost of form work and reinforcement for
reinforced concrete work in (c) Lintal for T floor
29 Providing and laying controlled cement concrete 306.00 Cumt 7768.92
M.200 and curing complete including the cost of
formwork and excluding reinforcement for
reinforced concrete work in (C) Ground floor
30 Providing and laying controlled cement concrete 295.00 Cumt 7768.92
M.200 and curing complete including the cost of
formwork and excluding reinforcement for
reinforced concrete work in (C) First floor Slab
Item Description of Item Quantity Unit Rate In Amount
31 Providing and laying controlled cement concrete 200.00 Cumt 7809.32
M.200 and curing complete including the cost of
formwork and excluding reinforcement for
reinforced concrete work in (C) Second floor
32 Providing and laying controlled cement concrete 8.00 Cumt 7848.71
M.200 and curing complete including the cost of
formwork and excluding reinforcement for
reinforced concrete work in (C) Third floor Slab
33 Providing and laying controlled cement concrete 38.00 Cumt 5987.28
M-200 and curing etc. complete including the
cost of form work and excluding the cost of
reinforcement etc. complete in RCC Vertical and
horizontal wall for GF
34 Providing and laying controlled cement concrete 17.00 Cumt 5987.28
M-200 and curing etc. complete including the
cost of form work and excluding the cost of
reinforcement etc. complete in RCC Vertical and
horizontal wall for FF
35 Providing and laying controlled cement concrete 28.00 Cumt 6026.67
M-200 and curing etc. complete including the
cost of form work and excluding the cost of
reinforcement etc. complete in RCC Vertical and
horizontal wall for SF
36 Providing and laying controlled cement concrete 43.00 Cumt 6067.07
M-200 and curing etc. complete including the
cost of form work and excluding the cost of
reinforcement etc. complete in RCC Vertical and
horizontal wall for TF
37 Providing and laying controlled cement concrete 16.00 Cumt 7202.31
M-200 and curing etc. complete including the
cost of form work and excluding the cost of
reinforcement etc. complete in (E) Stair case up
to floor two level for Ground Floor to first floor
38 Providing and laying controlled cement concrete 6.00 Cumt 7202.31
M-200 and curing etc. complete including the
cost of form work and excluding the cost of
reinforcement etc. complete in (E) Stair case up
to floor two level for First to Second Floor
39 Providing and laying controlled cement concrete 6.00 Cumt 7241.70
M-200 and curing etc. complete including the
cost of form work and excluding the cost of
reinforcement etc. complete in (E) Stair case up
to floor two level for Second to Third Floor
Item Description of Item Quantity Unit Rate In Amount
40 Providing and fixing 120 cm high Stainless steel 49.00 Rmt 3719.83
railing made from anticorrocive 304 grade S S
pipe of 50 mm dia (16Gauge) as hand rail with S
S 304 grade Baluster of 38 mm dia (16Gauge) as
a vertical support fixed in RCC slab at 1.2m c/c
including three horizontal S S pipes of 25 mm
dia (16Gauge) at eqal distance fixed by
mm dia (16Gauge) S S pipe with baluster
including accessories as per detailed drawing as
directed etc. complete.
41 Providing and fixing Stainless Steel Hand Railing 40.00 Rmt 1969.50
made from anticorrocive 304 grade S S pipe of
50 mm dia (16 Gauge) as hand rail with S S
grade Baluster of 40 mm dia (16 Gauge) as a
vertical support fixed in RCC member at 1.2m c/c
S S pipe with baluster including accessories as
per detailed drawing as directed etc. complete.
42 Providing IS Mark TMT FE 500D bar 488842.00 Kg 77.77
reinforcement for RCC work including bending &
placing in position complete up to All floor Level
43 Brick work using common burnt clay building 218.00 Cumt 3853.23
bricks having crushing strength not less than
Kg./Sq.m. in foundation and plinth in cement
mortar 1:6 (1 cement:6 fine sand) (b)
44 Brick work using common burnt clay building 590.50 Cumt 4141.66
bricks having crushing strength not less than
Kg./ Sqm. in cement mortar 1:6 ( 1 cement :
Fine sand ) in super structure above plinth level
upto floor two level ( for G.F ) Conventional
45 Brick work using common burnt clay building 261.00 Cumt 4141.66
bricks having crushing strength not less than
Kg/Sq.cm. in super structure in cement mortar
1:6 (1cement : 6 fine sand) {First FLoor}
46 Brick work using common burnt clay building 206.00 Cumt 4180.47
bricks having crushing strength not less than
Kg/Sq.cm. in super structure in cement mortar
1:6 (1cement : 6 fine sand) {SF FLoor}
47 Brick work using common burnt clay building 19.00 Cumt 4219.29
bricks having crushing strength not less than
Kg/Sq.cm. in super structure in cement mortar
1:6 (1cement : 6 fine sand) {TF FLoor}
48 Half brick masonry in common brunt clay 508.00 Sqmt 645.73
building bricks having crushing strength not less
than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1-
Cement : 4 -coarse sand ) in foundation and
plinth (B) Conventional for G floor.
Item Description of Item Quantity Unit Rate In Amount
49 Half brick masonry in common brunt clay 511.00 Sqmt 645.73
building bricks having crushing strength not less
than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1-
Cement : 4 -coarse sand ) in foundation and
plinth (B) Conventional for FF floor.
50 Half brick masonry in common brunt clay 331.00 Sqmt 651.63
building bricks having crushing strength not less
than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1-
Cement : 4 -coarse sand ) in foundation and
plinth (B) Conventional for 2nd floor.
51 Providing 15mm thick cement plaster in single 3367.00 Sqmt 184.61
coat on Rough (Similar)side of single or half
brick walls for interior plastering upto floor two
level and finished even and smooth in (ii)
Cement mortar 1:4 (1-cement :4-sand) 1x1cm
Groove at Jaunction. For GF
52 Providing 15mm thick cement plaster in single 3140.00 Sqmt 184.61
coat on Rough (Similar)side of single or half
brick walls for interior plastering upto floor two
level and finished even and smooth in (ii)
Cement mortar 1:4 (1-cement :4-sand) 1x1cm
Groove at Jaunction. For FF
53 Providing 15mm thick cement plaster in single 2689.00 Sqmt 212.49
coat on Rough (Similar)side of single or half
brick walls for interior plastering upto floor two
level and finished even and smooth in (ii)
Cement mortar 1:4 (1-cement :4-sand) 1x1cm
Groove at Jaunction. For SF
54 Providing 15mm thick cement plaster in single 559.00 Sqmt 240.38
coat on Rough (Similar)side of single or half
brick walls for interior plastering upto floor two
level and finished even and smooth in (ii)
Cement mortar 1:4 (1-cement :4-sand) 1x1cm
Groove at Jaunction. For TF
55 Providing 10 mm. Thick Mala plaster in single 2713.00 Sqmt 192.42
coat for plastering on ceiling and soffits of stairs
and finished in : (I) Cement mortar 1:4 (1
cement : 4 sand) with Mala finished of neat
cement slurry etc. complete.Ground Floor
56 Providing 10 mm. Thick Mala plaster in single 2290.00 Sqmt 192.42
coat for plastering on ceiling and soffits of stairs
and finished in : (I) Cement mortar 1:4 (1
cement : 4 sand) with Mala finished of neat
cement slurry etc. complete.F Floor
57 Providing 10 mm. Thick Mala plaster in single 1759.00 Sqmt 216.88
coat for plastering on ceiling and soffits of stairs
and finished in : (I) Cement mortar 1:4 (1
cement : 4 sand) with Mala finished of neat
cement slurry etc. complete.S Floor
Item Description of Item Quantity Unit Rate In Amount
58 Providing 10 mm. Thick Mala plaster in single 61.00 Sqmt 241.34
coat for plastering on ceiling and soffits of stairs
and finished in : (I) Cement mortar 1:4 (1
cement : 4 sand) with Mala finished of neat
cement slurry etc. complete.T Floor
59 20 mm Thick sand faced Double coat Gutka 8171.50 Sqmt 353.98
plaster on walls with 1x1cm grooves consisting
of 12 mm Thick backing coat of c.m. 1:3 (1
cement : 3 sand) and 8 mm Thick finishing coat
of c.m. 1:1 (1 cement : 1 sand) etc. complete. For
all height and as per pattern sample aprroved by
the architect or directed engineer in-charge
60 Providing throating or plaster drip and moulding 441.00 Rmt 44.07
to R.C.C. Chhajja.
61 Applying two coats of Birla or Asian acrylic lapy 16504.50 Sqmt 40.59
(putty) & two coats of primer of approved brand
and manufacture on new wall surface to give an
even shade including thoroughly brushing the
surface free from mortar dropping and other
foreign matter and sand papered smooth.
62 Wall painting (three coats) with plastic emulsion 9683.00 Sqmt 84.82
paint of approved brand and manufacture on
undecorated wall surface to give an even shade
to colour including throughly brushing the
surface free from mortar droppings and other
foreign matter and sand papered smooth.
63 Painting (two coats) with plastic emulsion paint 6821.00 Sqmt 90.48
of approved brand and manufacture on
undecorated ceiling surface to give an even
shade to colour including throughly brushing the
surface free from mortar droppings and other
foreign matter and sand papered smooth.
64 Wall Painting (Two coats) with weather proof 7943.50 Sqmt 122.14
100 % acraylic emulsion (Apex or equivalent
type) paint of approved brand and manufacture
and of required shade on exterior wall surface to
give an even shade over and including primery
coat with Alkaly resistance primer of approved
brand after thoroughly brushing surface to
remove all dust and remains of loose powdered
material etc. copm. for all height
65 Providing and laying controlled cement concrete 49.39 Cumt 8201.20
M-200 for RCC work and curing complete
including the cost of form work but excluding the
cost of reinforced concrete work in coping on
Item Description of Item Quantity Unit Rate In Amount
66 Providing and laying controlled cement concrete 6.00 Cumt 8201.20
M-200 for RCC work and curing complete
including the cost of form work but excluding the
cost of reinforced concrete work in coping on
67 Providing and laying controlled cement concrete 4.00 Cumt 8241.60
M-200 for RCC work and curing complete
including the cost of form work but excluding the
cost of reinforced concrete work in coping on S
68 Providing and laying controlled cement concrete 1.00 Cumt 8282.00
M-200 for RCC work and curing complete
including the cost of form work but excluding the
cost of reinforced concrete work in coping on T
69 Providing and fixing extruded aluminum window 375.00 Sqmt 2140.33
having extruded aluminum Colour Powder
Coated section frame main outer size 127mm x
Kg/mt,horizontal Four track member size
Kg/mt,vertical member of size 122.20mm x
31.75mm x 1.50mm ,@ Wt. 1.398 Kg/mt with
sliding shutters of horizontal member size 40mm
x 18mm x1.29mm @ wt.of 0.456Kg/mt,vertical
member of size 40mm x 18mm x 1.29mm @
wt.of 0.456Kg/mt,@ with 5 mm thick
transparent bronze colour tinted float glass with
powder coated aluminum fittings and fixtures
and transparent silicon sealant glass fixing to
frame as per details etc complete for window.
70 Providing and fixing window having extruded 10.90 Sqmt 1713.70
aluminum Colour anodized section frame main
outer size 63.50 x 38.10 x 1.95 mm,@ Wt
Kg / Rmt, horizontal two track member size
Kg/mt, vertical member of size 61.85 mm x
31.75mm x 1.30 mm @ wt.of 0.659 Kg/mt with
sliding shutters of horizontal member size 40mm
x 18mm x 1.29mm @ wt.of 0.456Kg/mt, vertical
member of size 40mm x 18mm x 1.29mm @
wt.of 0.456Kg/mt, @ Wt. 0.457 Kg/mt with
mm thick transparent bronze colour tinted float
glass with powder coated aluminum fittings and
fixtures and transparent silicon sealant glass
fixing to frame as per details etc complete for
Item Description of Item Quantity Unit Rate In Amount
71 Providing & Fixing in position standard extruded 35.00 Sqmt 1834.16
approved colour anodised Aluminum
Window/Ventilation with outer frame (of Jindal
Section No.21458,@ Wt0.650 kg/Rmt ) with
3mm thick Bajari figure adgesteble tinted
louvers glass fixed to alluminium strip blade
including fixtures, fastenning, labours and
equipments as per detailed drawing as directed.
For Ventilators
72 Providing and fixing 12mm thick toughened 246.00 Sqmt 4585.40
glass fixed panel partition with machine
polished arris edges on all sides, fixed with
anodized aluminum U-channels (top, bottom and
sides) of size 25mm x 25mm x 1.5mm thickness,
including silicone gaskets, ,all necessary
accessories, complete surface preparation using
appropriate cleaners and primers, proper
handling and positioning of glass panels
including all labor for installation, finishing and
clean-up, all complete as per specifications and
directions of the Engineer-in-charge.
73 Providing & Fixing in position standard extruded 3.00 Sqmt 2148.27
approved colour anodised Aluminum
Window/Ventilation with outer frame (of Jindal
Section No.21458,@ Wt0.650 kg/Rmt ) with
6mm thick Dark glass fixed to alluminium strip
blade including fixtures, fastenning, labours and
equipments as per detailed drawing as directed.
For Ventilators
74 Providing and fixing anodized aluminium section 222.00 Sqmt 4082.42
door frame equivalent to Jindal Section No.
including internal wooden inserts for firm grip of
hinges and hardware. Door shutter shall be
double shutter type, solid core flush door,
finished with 1 mm thick laminate on both sides.
The work includes fixing with stainless steel
handle, floor spring, and all necessary S.S.
hardware and accessories complete as per
drawing and direction of engineer-in-charge.
Item Description of Item Quantity Unit Rate In Amount
75 Providing and fixing FRP frame size 100 x 50 mm 46.00 Sqmt 2362.39
and 35 mm thick FRP depress panel
Double/Single shutter having extra
reinforcement on sides & edges in Gel coat
finish.The core of the both shutter & frame is to
be filed up with injected fire retradat grade
polyurethene foam done in situ along with
embeded wooden pieces for stiffening & also
taking hinges & fintures.The whole FRP frame &
double shutter is to be waterproof, weatherproof
,termite proof & resistance to mild
acid/alkali.Rates are to be inclusive of S.S hinges
with necessary screws & alluminum fixtures &
fastenings & fartener sleeve.Colour and Shade
approved by Engineer-In-Charge.
76 Providing and fixing 12mm thick compact 11.00 Sqmt 5835.15
laminate panel door made of high pressure
laminate with phenolic resin core and decorative
melamine surface on both sides, with stainless
steel butt hinges , mortise lock set with lever
handles, SS Door Handle , door closer as
required, all necessary stainless steel screws,
fasteners, , door hanging and final adjustments
for proper operation, all complete as per
specifications, approved samples and direction
of Engineer-in-charge.
77 Providing and fixing anodized aluminum section 13.50 Sqmt 3735.99
frame equivalent to Jindal Door Section No.
19552 with weight not less than 1.1 kg/meter
(frame size 38mm × 63.5mm), including double
shutter pivoted flush door with floor spring, solid
core finished with 1mm thick lamination on both
sides, complete with stainless steel handle and
other stainless steel fixtures, including all
necessary hardware, fasteners, adhesives,
aluminum cleats, weather strips, EPDM gaskets,
silicon sealant as required, including cutting,
fabrication, installation and final adjustments for
proper operation, all complete as per
specifications, approved samples and direction
of Engineer-in-charge.
78 P & L 60x45 cm Mirror polished Blue Kota Stone 4701.50 Sqmt 1121.80
slab flooring over 20 mm (average)thick base of
cement mortar 1:6 (1-cement 6-coarse sand) or
L.M 1:1.5 (1 Lime putty : 1.5 coarse sand laid
over and jointed with grey cement slurry mixed
with pigment to match the shade of slab
including rubbing and polishing etc.complete (A)
Item Description of Item Quantity Unit Rate In Amount
79 Providing and laying polished kota stone slab 220.00 Sqmt 1205.60
25mm thick in risers of steps,skirting Dedo and
pillars laid on 10mm thick cement mortar 1:3 (1-
Cement : 3 coarse sand) and jointed with gray
cement slury mixed with pigment to match the
shade of slab including rubbing and polishing etc.
80 Providing and laying Ceramic tiles 6mm thick in 168.50 Sqmt 1017.30
flooring treads of steps and landing laid on a bed
of 12mm thick cement mortar 1:3 (1 cement : 3-
coarse sand ) finishing with flush pointing in
81 Providing and laying coloured glazed tiles of the 472.00 Sqmt 1523.67
size 300 mm x 200 mm x 8 mm / 300 mm x
mm x 8 mm in skirting, risers of steps and dedo
on 10 mm. thick cement plaster 1:3 (1 cement :
coarse sand) & jointed with white cement slurry.
82 Providing and laying machine cut free edge 116.00 Sqmt 817.09
Polished Kota Stone Slab Green. 25 mm thick
finished treadsin with 1cm projecting, nozing
rounded moulding in tread laid over 12 mm (av.)
thick bases of cement mortar 1:6 (1-cement : 6-
coarse sand) jointed with grey or colour cement
slurry including rubbing and polishing incl.
making Three No.s of grooves of size 3mm X
3mm along the length of treads etc. complete
83 Providing and laying water proofing treatment 2236.50 Sqmt 779.70
with broken chine mosaic flooring for terrace
using 12 mm to 20 mm broken pieces of glazed
tiles to be laid over cement mortar 1:3 to plain or
slope and to be tempered to bring mortar
creme out upto surface using white cement
including rounding off junctions and extending
them upto 15 cm along the wall, clearing with
water and oxalic acid etc. as directed.
84 Providing and laying cement concrete flooring 2236.50 Sqmt 355.69
1:2:4 (1-cement : 2-coarse sand : 4-graded stone
aggregate 20mm nominal size) laid in one layer
and finished with a floating coat of neat cement.
(B) 50mm thick.
Item Description of Item Quantity Unit Rate In Amount
85 Providing Plinth Protection to Building including 299.00 Sqmt 2484.20
excavation in ordinary soil and laying cement
concrete 1:3:6 using stone aggregates of 40mm
nominal size in foundation layer 125 mm thick+
125mm thick sand layer below pre-cast Rubber
Dye inter locking concrete block 60mm thick
with grade of concrete M300 pneumatic
compressed by mechanically pressed and as per
approved design including 75mm Sand layer
for levelling and filling the joint with sand in
proper line and level etc. complete, Including
Providing and fixing pre-cast concrete kerb stone
of grey cement based concrete block 30cm
length, 30cm height and 15cm thick made of
M250 grade concrete as per approved design
and including excavation for fixing in proper line
and level, filling the joint with C:M 1:3
(1cement:3 fine sand) etc. complete.
86 Providing and fixing mirror polished Marble Slab 632.50 Sqmt 1354.41
18 to 20 mm with full round edge and polished
of approved quality in clading on sill and around
the doors/ windows/ ventilation with 12 mm
thick cement mortor CM (1:4) and fixing with
cement slurry & adhesive including moulding of
exposed edges as directed by engineering in
charge etc. complete.
87 Providinfg and fixing Safty grills of required 18590.00 Kg 159.78
pattern for windows/ Door using necessary M.S
angle/ M.S pipe, M.S flats and other structural
steel at required spacing including cutting,
welding and fabriction etc. including one coat of
primer of approved quality and two coats of oil
painting as per detail drawing etc complete.
88 Providing erecting and fixing double coated 20000.00 Litre 3.95
Syntex PVC. (ISI) water tank of required capacity
each with all necessary fittings and connection
etc. complete on terrace.
89 Providing laying and jointing in true line and 60.00 Rmt 195.67
level 50mm dia. U.P.V.C. Pipe ( SCH- 40) for cold
water including fittings make PRINCE /
SUPREME / ASTRAL / FINOLEX or equivalent as
approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every
two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing
of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Item Description of Item Quantity Unit Rate In Amount
90 Providing laying and jointing in true line and 80.00 Rmt 148.12
level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold
water including fittings make PRINCE /
SUPREME / ASTRAL / FINOLEX or equivalent as
approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every
two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing
of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
91 Providing laying and jointing in true line and 240.00 Rmt 91.84
level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold
water including fittings make PRINCE /
SUPREME / ASTRAL / FINOLEX or equivalent as
approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every
two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing
of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
92 Providing laying and jointing in true line and 210.00 Rmt 72.65
level 15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold
water including fittings make PRINCE /
SUPREME / ASTRAL / FINOLEX or equivalent as
approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every
two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing
of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
93 Providing, laying and jointing in true line and 40.00 Rmt 834.38
level 160 diametre U.P.V.C (Type B) conforming
to IS 13592-1992 with one end plain and other
end socketed with rubber ring, & fittings
conforming to ISI 14735-1999 of approved make
for drainage system pipe line, pipe shall be
jointed with each other with rubber lubricant,
pipe shall be fixed on wall using of PVC clamp of
the size 160 mm diametre x 210 mm length x
196 mm heigh at every 2000 mm center to
center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes
etc. including testing of pipes and joints and
jointed with adhesive solvent cement including
cost of all materials.
Item Description of Item Quantity Unit Rate In Amount
94 Providing laying (to level or slopes) and jointing 597.00 Rmt 677.93
reinforced concrete Light duty non-pressure
pipes I.S. class NP2 of the following internal
diameter with collars and butt ends prepared for
collar joints including testing of joints
95 Providing, laying and jointing in true line and 282.40 Rmt 897.79
level 110 diametre U.P.V.C (Type B) conforming
to IS 13592-1992 with one end plain and other
end socketed with rubber ring, & fittings
conforming to ISI 14735-1999 of approved make
for drainage system pipe line, pipe shall be
jointed with each other with rubber lubricant,
pipe shall be fixed on wall using of PVC clamp of
the size 110 mm diametre x 149 mm length x
145 mm heigh at every 2000 mm center to
center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes
etc. including testing of pipes and joints and
jointed with adhesive solvent cement including
cost of all materials.
96 Providing, laying and jointing in true line and 40.00 Rmt 777.70
level 75 mm dia. UPVC SWRType B pipe
conforming to IS 13592-1992 with one end plain
and other end socketed with rubbering and
fitting conforming to ISI 14735-1999 of
approved make for drainage system pipe line,
pipe shall be jointed with each other with rubber
lubricant, pipe shall be fixed on wall using of PVC
clamp at every 2000 mm c/c or shall be
conceled in walss as directed including necessary
fittings such as bends, shoes etc. including testing
of pipes and joints and jointed with adhesive
solvent cement including cost of all materials.
97 Providing and fixing in PVC SWR cowel went 2.00 No 15.66
75mm dia to pipes.(B) 75mm dia.
98 Providing and fixing in PVC SWR cowel went 12.00 No 28.79
110mm dia to pipes.(B) 110mm dia.
99 Providing and fixing PVC SWR Nahni trap IS 33.00 No 600.23
14735 for drain - 100 mm diameter with jali of
the following nominal diameter of self cleansing
design with C.I scread down or hinged grating
including the cost of cutting and making good the
Item Description of Item Quantity Unit Rate In Amount
100 Providing and fixing wash down water closet 15.00 No 2853.25
(European type W C pan) with integral P and S
trap including jointing the trap with soil pipe in
cement mortar 1:1 (1 cement five sand)
including providing and fixing plastic seat cover
for wash down WC with CP brass hinges and
rubber buffers back plastic seat with a pair of C I
or MS bracket with complete fitting such as lead
valve siphon 15 mm dia brass ball valve with
polythene float CP brass handle unions and
couplings for connection with inlet out let and
over flow pipes 40 mm dia porcelain enameled
flush bend including cutting holes in walls and
making good the same connection the flush bend
with cistern and closet vitreous china.
101 Provision and fixing water closet squatting orissa 6.00 No 1849.31
type W.C. pan size 580mm integral footrest and
100 mm P or S trap and in cluding 25 mm dia CP
brass flush valve and GI inlet connection etc.
comp. (A) Vitreous china long pattern white or
102 Providing and fixing stainless steel grab 22 cm x 6.00 No 1492.78
60 cm for handicapped toilet
103 Providing and fixing brass screw down stop 48.00 No 205.83
tap.(A) 15mm dia
104 Providing and fixing washbasin with single hole 15.00 No 2081.61
for pillar tap with C.I. or M.S. brackets painted
white including sutting holes and making good
the same including Brass waste, and M I fisher
union fittings including pvc connection and
waste pipe & all necessary fittings For All Floor
(A) Vitreous China:(ii) Flat Back washbasin
mm x v 400mm size. (i) In white colour
105 Providing and fixing 600mm x 450mm bevelled 12.00 No 859.41
edge mirrror of superior glass mounted on 6mm
thick A.C. sheet or plywood sheet and fixing to
wooden pluge with C.P. brass screws and
106 Providing and fixing ball cock of approved. 2.00 No 189.84
quality as directed.(A) Copper Metal (ii) 50mm
107 Providing and fixing screw down bib taps of 15.00 No 186.83
following size.(A) Brass screw down bib tap
polished bright. (i) 15mm dia.
108 Providing and fixing C.P. brass towel rail comlete 9.00 No 616.42
with C.P. brass brackets fixed to wooden plugs
with C.P. brass scews.(B) 600mm x 20mm size.
Item Description of Item Quantity Unit Rate In Amount
109 Providing and fixing in position 300 mm high, 100.00 No 707.00
150 mm wide English letters made from 1.0 mm
thick stainless steel sheet as directed by
Engineer in charge with all necessary tools &
plants etc. complete.
110 Providing and laying (two level or slopes) and 120.00 Rmt 531.04
jointing with stiff mixture of Cement Mortar in
proportion 1:1, Salt glazed stone ware pipes of
pipes 150mm laying lime concrete 1:2:4 (1-Lime
putty :2-Fine samd : 4-Graded brick aggregates
40mm nominal size) bedding for stoneware
pipes of following internal diameters with
necessary formwork and curing complete.
111 Providing and fixing S.W. gully trap with C.I. 6.00 No 1246.92
grating brick masonry chamber and water tight
C.I. cover with frame of 300mm x 300mm size
(inside) with standard weight (i) Square mouth
traps (B) 150mm x 100mm size P or R type
112 Constructing brick masonry chamber for 34.00 No 3454.79
underground C.I. Inspection chamber and bends
with briocks having croshing strength not less
than 35Kg. Cm2 in C.M. 1:5 precast RCC cover
455mm x 610mm intenal dimensions with frame
(R.C.C. top slabe with 1:2:4 mix (1-cement :2-
coarse sand :4-graded stone aggregate 20mm
size) foundation concrete 1:5:10 inside plaster
15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on
walls and bed concrete etc. complete (i) Inside
dimensions 455mmx 610mm and 450mm deep
for single pipe line.
113 Constructing brick masonry chamber for 20.00 No 4258.97
underground C.I. Inspection C.I. Inspection
chamber and bends with briocks having croshing
strength not less than 35Kg. Cm2 in C.M. 1:5
precast RCC cover 500mmx 700mm intenal
dimensions with frame (R.C.C. top slabe with
1:2:4 mix (1-cement :2- coarse sand :4-graded
stone aggregate 20mm size) foundation concrete
1:5:10 inside plaster 15mm thick with cement
mortar 1:3 finished smooth with a floating coat
of neat cement on walls and bed concrete etc.
complete (i) Inside dimensions 500mmx 700mm
and 450mm deep for single pipe line.
114 Extra over items for every additional depth of 10.00 Each 242.39
0.1M. of part thereof beyond 450mm depth for
Brick masonry chamber.(i) for 455mm x 610mm
Item Description of Item Quantity Unit Rate In Amount
115 Extra over items for every additional depth of 10.00 Each 264.86
0.1M. of part thereof beyond 450mm depth for
Brick masonry chamber.(i) for 500mm x 700mm
116 Providing and fixing MS Ladder of required 300.00 Kg 126.15
pattern with MS flats(30x3mm) or round or
square bars (12mm) at required spacing & with
round headed bolts and nuts or screws or
welding including primer coat of approved
quality and two coats of oil paintas as directed
by engineer in charge
117 Providing and fixing in position 150 mm high, 100.00 No 404.00
English letters made from 1.0 mm thick stainless
steel sheet as directed by Engineer in charge
with all necessary tools & plants etc. complete.
118 Constructing drinking/Handwash Platform of 14.00 Sqmt 9602.07
18 mm thick Polished Black Granite having
0.45m width and 0.60m height including 0.60m
support at every 0.7m c/c with cementing
Materials / adhsives including makeing
necessary grooves in walls including Wash Basin
Snow White size 400x400x135mm including
Polyamide braided connection pipe 12mm dia,
450mm length Wast coupling with ceramic Pop-
up push type (Full thread) 32mm Dia Cat. No.
F8050351 with all fitting inlet and outlet
connection and all required fitting accessories
etc. with all labour material of approved quality
incl. full moulded round front edge granite strip
of one side polished and jointed with grey
cement slurry including rubbing and polishing
etc. complete for all floors
119 Providing and fixing Urinal of approved quality 12.00 Nos 1674.15
including connection with trap and with integral
longitudinal flush pipe.(A) Squating plate pattern
white earthenware 550mm x 300mm.
120 Providing and fixing polished 18 mm thick black 8.00 Sqmt 2897.69
granite with full round edge and double side
polished of approved quality in between urinal
and fixing with cement slurry & adhesive
including moulding of both exposed edges as
directed by engineering in charge etc. complete.
121 Charges for making holes from 50mm to 160 mm 100.00 No 858.50
dia in RCC wall, slabs or any other RCC members
or Brick work by diamond core cutting machine
of HILTI or equivalent including disposing the
debris. For all floors .
Item Description of Item Quantity Unit Rate In Amount
122 Providing and fixing coloured self adhesive PU- 81.00 Sqmt 4586.41
Tactile tile, ground surface indicators of
Polyurethane) of size 300mm x 300mm for
guiding/warning to the visually visitors in the
centre/side of the pedestrian/approach pathway
as per specification and guidelines complete in
all respect to the entire satisfaction of in charge.
123 Providing and fixing 150 mm wide, approved 1215.00 Sqmt 368.65
quality chicken wire mesh at junction of brick
work and RCC work or two dissimilar surfaces, at
all heights fixed by nails, rowal plugs or tag by
cement mortar 1:3 before applying the plaster,
including curing, scaffolding all complete as
124 Providing and fixing acrylic multilingual Braille 36.00 Nos 1696.80
(raised dots) DIRECTIONAL SIGNBOARDS of size
225 x 150mm designed as per accessibility
standards and having 3.5mm thick acrylic base
plate with Upper Case San Serif words made of
white acrylic non glare cut out letters of height
15mm raised not less than 0.8mm above base
plate and the equivalent word written in Hindi
with Devanagari non glare acrylic letters of
height 15mm raised not less than 0.8mm above
base plate and having a non-glare acrylic cut
arrow pointing in the required direction. Each
signboard to be fixed as per manufacturers
specifications on the wall at the approved
location and at a height of 1200mm from FFL
complete as per design / specifications and
guidelines as per the entire satisfaction of the
Engineer-in-charge
125 Providing And filling with good quality 14.00 cumt 555.50
sinder(steam coal) as directed by engineer in
charge in sunks in layers of 15 cm thick,including
watering,placing ,ramming well etc as directed,
Item Description of Item Quantity Unit Rate In Amount
126 Providing & Fixing tactile layout plan of size 1.00 Nos 33027.00
900mm x 600mm as approved design, made of
3.0mm thick acrylic non glare base plate and non
glare cut out symbols with Braille on which
individual facility points, like inquiry, reception,
restrooms, medical room / first aid, cafeteria or
breakout area, lounge, meeting room, conference
room etc. present the respective floors with
pictograph wherever needed all in tactile raised
by minimum of 1.0mm to 2mm in various
colours to make it legible for seniors, partial
vision impaired etc. All the facility names should
be in Braille, along with English or Hindi. The
entire block of tactile signs should be mounted
on wall for easy reading. The map to be installed
at specified locations and installed at a height of
800mm from ground level complete in all
respect as per Harmonized guideline &
satisfaction of Engineer in charges.
127 Providing and fixing of acrylic, non-glare, tactile 1.00 Nos 43480.50
audio pictorial building layout as per the
approved size, design and make, having 3mm
thick acrylic non glare base plate of the approved
colour and non-glare acrylic cut out symbols
raised 3mm above base plate and Grade 2/
Grade 1 Braille to be integral with the sign face
and be raised 0.5mm above base plate. The map
to be installed at the specified location as per
accessibility standards, shall be oriented to the
position of the viewer and to be installed at a
height of 800 mm from the finished ground/
floor level and using the necessary hardware
specified by the manufacturer and to be installed
up to the height of 800 mm from the finished
ground/ floor level and using the necessary
hardware specified by the manufacturer and to
be installed complete as per
design/specifications and guidelines as per the
entire satisfaction of the the Engineer-in-charge
128 Providing & fixing Braile indicator of size 170 120.00 Rmt 820.12
mm x 35mm for handrails of the approved
design and make have braile dots raised 0.5 mm
above base plate to be installed at specific
locations as per direction of engineer in charge
Item Description of Item Quantity Unit Rate In Amount
129 Providing and fixing of conspectus tape 50mm 120.00 Rmt 1247.35
width on of treads in staircase including cutting
pasting etc. As per harmonised guidelines
complete in all respect to the entire satisfaction
of engineer in charge.
130 Providing and fixing eco-friendly light weight 1923.00 sqmt 1674.15
calcium silicate false ceiling tiles having Tegular
edge & 15 mm Thick Densified edges on the Tile
Periphery for Extra Strength The Light weight
calcium silicate ceiling tiles shall have , light
reflection 85% noncombustible as per B.S.
part IV, 100% humidity resistance and also
having thermal conductivity0.043° w/m KC.for
the best thermal Insulation . The Light weight
calcium Silicate tile shall be of approved texture
Fine fissured/ Spintone/Cosmos having NRC
value of 0.5 & Globe having NRC value of
NRC or equivalent of size 595 X 595 mm to be
laid on true horizontal level suspended inter
locking metal grid of hot dipped galvanized steel
sections (galvanizing @120 grams per sqm
including both side) consisting of main ‘T’ runner
suitably spaced at joints to get required length
and size of 24X38mm made from 0.30 mm thick
(minimum) sheet, 1200mm centre to centre, and
cross ‘T’ of size 24X28mm made out of 0.33mm
(Minimum) sheet spaced 1200mm along spaced
between main ‘T’ at 600mm centre to centre to
form agrid of 1200X600mm and secondary cross
’T’ of length 600mm and size 24x28mm made of
0.30 mm thick (Minimum) sheet to be
interlocked at middle of the 1200X600mm panel
to form grid of size 600X600mm resting on
periphery walls/partitions
131 Providing and on a perimeter
fixing C.I. Manhole wall
cover 0.60 M. x 1.00 Nos 958.17
0.45M. size having weight not less than 35Kg.
132 Providing & erecting open well horizontal mono 1.00 Nos 39632.40
block pump set with cast iron body, complete for
three phase submersible motor having [H]For
H.P,3 phase open well horizontal mono block
pump set suitable for 1000 LPM to 1140 LPM @
20 to 39 MTR head suitable for 65/80 mm dia
Item Description of Item Quantity Unit Rate In Amount
133 Supplying & erecting approvedmake 3 phase 1.00 Nos 19695.00
motor control cubicalpanel (Star-Delta) made
from 16G.CRCA sheet duty painted with epoxy
powder painted inside and outside with hinged
doors and locking arrangement, consisting
suitable size of ON-OFF isolator (AC- 3/23duty)
main fuses,single phasing preventer cum water
level, Guard(Compe unit), Toggle switch to by
pass Single phase preventercum WLG,indicating
lamps forR-Y-Bphases, over load relay.Automatic
water level controller, Ammeter &Voltmeter
each with two way selector switch incoming
wires duty socket Crimped,Panel to be erected
on angle iron frame grouted on wall as overload
relay,thermal/Electronics star delta cutoff
timer,start-stop push buttons.The isolator
overload relay &cntractors ofL&T,Siemens or
Cuttler Hamer make only.Panel to be erected on
angle iron frame ground on wall (e)S/D upto
134 Providing and fixing rolling shutters of approved 5.00 Sqmt 3554.40
make made of 80 mm wide M.S laths inter-locked
together through heir entire length and jointed
together at the ends by end locks mounted on
specially designed pipe shaft with bracket
plates,guide channels and arrangement for inside
and outside locking with push-pull operation
including the cost of hood cover and sprig
etc.complete(A) Shutters having width below
135 Drilling pilot borehole of size 250/300 mm at 100.00 Rmt 853.25
above site by mud flush direct rotery rig.
136 Reaming of 250/300 mm dia.Pilot borehole to 15.00 Rmt 527.95
size 550 mm dia. Incliding assembling ,lowering
housing ,casing strainerpipers with gravel
packing and clayball packing etc.
137 Development of cach water bearingzone coming 1.00 Job 13212.90
across the full depth of tubewell by lowering
mm dia.Droplineand 32 mm dia airline for each
water bearing Zone with suitabale capacity air
compressar up to avilability of sand free
138 900 CFM /200 PSI capacity air compressar upto 1.00 Job 27206.17
the availability of sand free discharge for upto
139 Supply of M.S. E.R.W. plain end medium duty 100.00 Rmt 2440.64
pipe confirming to IS 4270/2001 with latest
amendments Of size 250 mm dia (minmum
thicknes of 7.1 mm)
140 Screen Slotting of MS ERW balnce pipe with size 200.00 slots 0.22
of slot 6.75 cm X 6.35 cm X 3.12 mm for 250 mm
Item Description of Item Quantity Unit Rate In Amount
141 Supply of miscellenious bore material suitable to 1.00 Pair 1912.70
250 mm dia pipes as following (A) MS Bore
clamps made from M.S. plate with 3 holes on
either side with nuts & bolts of std make of size
900X100X16 mm flat suitable for 250 mm dia
142 Supply of miscellenious bore material suitable to 1.00 No 1385.64
250 mm dia pipes as following (B) MS Bore Plug
having 100mm height made from M.S. plate with
3 holes at equal distance on circumferrence for
nut-bolts type, locking arrrangement with nuts-
bolts & lock nuts of std make complete from
mm thick M.S. plate suitable for 250mm dia pipe.
143 Supply of miscellenious bore material suitable to 1.00 No 999.90
250 mm dia pipes as following (C) MS Bail Plug
having length 0.45 mtr from medium class pipe
as per I.S. suitable for 250 mm dia pipe.
144 Supply of miscellenious bore material suitable to 168.00 NO 86.21
250 mm dia pipes as following (D) Steel bent
plate suitable for ERW pipe for 250mm dia
(size:200 X 150X6 mm)
145 Supply of GRAVEL OF selected size 4 mm to 6mm 40.00 Cum 2020.24
146 Electrologging of Pilot bore hole with carting. 1.00 Job 10665.60
147 Geohydrological ground water investigation 1.00 No 14220.80
including vehicle charges for three phase DTH
bore/DR tube well including water sample
testing & chemical analysis
148 Providing, supplying and commissioning ISI 1.00 No 4753.30
mark CI D/F Reflux Valves of following class and
diameter including all taxes, insurance,
transportation, freight charges, octroi, inspection
charges, loading, unloading, conveyance to
departmental stores stacking etc. complete.
Reflux valves PN 1 IS 5312 with ISI mark size:
149 Providing and laying in trenches galvanised mild 100.00 Rmt 919.80
steel tubes (Midium grade) of the following
nominal bore, and tube fitting (Earthwork in
trenches to be measured and paid for separately
Item Description of Item Quantity Unit Rate In Amount
150 Constructing Manhole with R.C.C. top slab in 5.00 No. 11042.74
1:2:4 mix (1-cement :2-coarse sand : 4-graded
stone aggregate 20mm nominal size) foundation
concrete 1:3:6 mix (1-cement : 3- coarse sand :6-
Brick bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:3 (1-Cement :
3-coarse sand) finished with a floating coat of
neat cement and making channels in cement
concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-
stone aggregate 20mm nominal size) finished
smooth complete including curing and festing (i)
Inside size 900mm x 1200mm and 1.5M. deep
including C.I. cover with frame size 560mm
diameter total weight of cover and frame to be
not less than 128 kgs. (Wt. of cover 64 Kg. and
Wt. of frame 64 Kg.)(A) With 230mm thick walls
of brick msonry using brick having crushing
strength not less than 35Kg. / Sq.cm. in Cement
Mortar 1:5 (1- Cement: 5- Coarse sand) (1) A
type depth 0.90 Metre for 150mm diameter
151 Providing and fixing and floor 10.0 Kg. F/Cm2 166.00 Rmt 339.05
working pressure poluthene pipes of the
following outside Dia. Low densidy, complete
with special falnge compression type fittings,
wall clipsetc. including making good the wall
ceiling and floor.(G)110 mm
152 Providing and fixing and floor 10.0 Kg. F/Cm2 40.00 Rmt 696.90
working pressure poluthene pipes of the
following outside Dia. Low densidy, complete
with special falnge compression type fittings,
wall clipsetc. including making good the wall
ceiling and floor.(G)180 mm
153 Providing junction for rain water juncton 4.00 Nos. 8633.48
chamber of size 0.60x0.60x0.75m with
excavation of size 1.96x1.96 m & 0.15m thick
c.c.1:2:4 bed concrete including brick masonary
wall in CM 1:6 of 0.75m height & 0.23m thick
with 15mm thick cement plaster inside & outside
& 1.06x1.06 RCC (1:2:4) slab of thickness 0.15m
with CRS steel and 0.60mx0.45m cast iron
manhole cover with frame weight not less than
35 kg as per directed by Engineer-in-charge
Item Description of Item Quantity Unit Rate In Amount
154 Providing and installation Recharge pit of 2.00 Nos. 109645.60
“RAIWOHA” Make 3 layer RCC Precast Injection
well system of size 1.5 meter Dia. X 3.4 Meter
Height rein forced concrete precast three layer
module with 6” dia x 12” dia. V wire screen of
0.75mm x 1.0 mm Slot size in SS 304 material
and 1.0 meter height with MS Top cover and
required Air vent including all necessary
excavation and transportation at site including
required filter media for the recharge system as
per site requirement.
155 Drilling of min. 250 mm dia. bore hole in all 100.00 Rmt 1252.32
strata including dualover burden strata by
combination DR/DTH rig including lowering
mm dia MS ERW pipes in bore hole and testing
etc.all work as per directed engineer incharge.
156 Supplying slotted PVC pipes of approved quality 100.00 Rmt 555.50
at site of work confirming to IS. 1239/1974
157 Construction of granular sub-base 150 mm thick 345.80 Cum 1609.94
by providing coarse graded machine crushed B.T.
material satisfying MOST specification of grading
I (B.T. stone aggregate 53 mm to 26.5 mm 35 %,
26.5 to 4.75 mm - 45 % and 2.36 mm below -
% )including spreading in uniform layer with
motor grader on prepared surface, mixing by mix
in place method with rotavator at OMC and
compacting with vibratory roller to achieve the
desired density etc. complete.
158 Steel work, welded in built up sections framed 31449.00 kg 90.55
work including cutting, hoisting, fixing in
position and applying a priming coat of read lead
paint & two coat oil paint. (A)In beams and joists,
channels angles Tees, flats, with connecting
plates or angle cleats as in main and cross beams.
Hip and jack rafters, purlins conneted to
common rafters and the like..
Item Description of Item Quantity Unit Rate In Amount
159 Providing and fixing of Ridge flashing for roof 792.00 Sqmt 858.67
panel shall be made out of 0.5 mm thick pre
coated GI sheet . The Precoated sheet shall be of
minimum 240 mpa steel grade confirming to IS
14246:1995 and shall have zinc coating of
minimum 120 gsm as per IS:277:1992 , 5-7
microns epoxy primer on both side of the sheet
and polyester top coat 15-18 micron. The PPGI
Sheet shall have plastic protective guard film of
minimum 25 microns to avoid scratches during
transportation. The ridge shall be fixed to the
steel members by pop rivet or self drilling/self
stitching fastners @ maximum 450 mm c/c along
length of capping/flashing etc complete .
160 Providing and fixing pre-cast Rubber Dye / steel 1803.00 Sqm 689.20
Dye inter locking concrete block 60mm thick
with grade of concrete M300 pnumatic
compressed / vibrated mechanically and as per
approved design Confirming to IS 15658 :
including 35 mm Sand layer for levelling and
filling the joint with sand in proper line and level
as per guidlines of IRC : SP 63-2018 etc.
161 Providing and fixing pre-cast concrete kerb stone 494.00 Rmt 370.83
of gray cement based concrete block 30cm
ength,30cm height and 15cm thick of M250
grade concret as per approved design and
including excavation for fixing in proper line and
level,filling the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
162 Box cutting the road surface to proper slope and 737.00 Cum. 112.02
camber for making a base for road work
including removing the excavated stuff and
depositing on the road side slope as directed
upto upto All lift and lead..
163 Providing, laying and compacting natural sand & 108.00 Cum. 683.77
gravel[ C.B.R. not less than 20%] below sub base
course including carriage of materials spreading
in uniform layer manually on prepared base and
compacted with vibratory roller to achieve
desired density including all materials, labour
164 Providing and laying wet mix macadam base 313.00 Cum. 1679.63
course 250 mm thick in two layers using
machine crushed B.T. chips as per required
gradation mixing with required optimum
quantity of water, conveying the mix to site of
work, spreading in to grade and camber with
mechanical paver and consolidation each layer
with vibratory roller including cost of material
labour plant and equipment etc. complete.
Item Description of Item Quantity Unit Rate In Amount
165 Compaction and finishing of cement concrete 1026.00 Sqm 65.65
road by trimix process providing extra Labour
charges for the trimix vacume dewatering
service process on cement concrete road sutface
by using vacuum dewatering pump floater
surface vibrator including making groves and
rough finish to surface including leveling etc
166 Providing and fixing concertina coil fencing with 860.00 Rmt 864.56
punched tape concertina coil 600 mm dia 10 mt
openable length having 50 no rounds per 6 mt
length, upto 3mt height of wall with existing
angle iron (50mm x50mm x5mm )requird
shaped As per Directed Engeenier in charge.
placed 2.4mt or 3.00mt apart and with
horizontal R.B.T. reinforced barbed wire(3 mm)
stud tied with G.I. staples and G.I. clips to retain
horizontal, including necessary bolts or
G.I.barbed wire tied to angle iron, all complete as
per direction of Engineer-in-charge, with
reinforced barbed tape (R.B.T.)/Spring core (2.5
mm thick) and weight 43.478 gm/meter at
compound wall for ESR M4/ intakewell.
167 Constructing providing and fabricating cattle 5.00 Sqmt 5056.06
guard using channel section frame of size ISMC
series 100 mm x 50 mm (Weight 9.20 kg/Rmt)
and ISMC section 100 mm x 75mm (weight
kg/Rmt) intermediate support for welding
G.I.pipe at 12 Cm C/C of size 50 mm in a frame
made of Channel section size 100 mm x 50 mm
all round including fixing the unit on prepared
chamber of masonary wall using MS hold fast
embeded in masonary wall top as directed by
Engineer in charge and as per drawing and
necessary required arrangement etc complete.
168 Supplying of well rotted FYM manure with all 38.00 Cum. 378.75
lead and Lift including spreading mixing dressing
and rolling with hand roller etc. complete.
169 Scarifying the surface of Soil including spreading 1495.00 Sqm 26.26
of DAP fertilizer mixing with Soil properly
levelling gand dressing of the plot
170 Supplying and planting Dibbing semi carpet lawn 1495.00 Sqm 20.20
at distance of abour 15 cm x 15 cm after proper
anti termite teratment amd rolling the seme by
hand roller amd wetering etc complete.
Item Description of Item Quantity Unit Rate In Amount
171 Bowing and developing flowering plants grown 10.00 No. 30.30
in nusery having approximate height 4 to 5 ft or
Height ad per Landscaps Plan with natural
growith of soil packed in polithyline bag or
Earthern pot. Including organic & chemical
fertilizer Pesticides, fungicides, hormones &
maintaining the plants up to three months as
deserted. Bottol palm.
172 Bowing and developing flowering plants grown 10.00 No. 60.60
in nusery having approximate height 4 to 5 ft or
Height ad per Landscaps Plan with natural
growith and nature colour planted in alump of
soil packed in polithyline bag or Earthern pot.
Including organic & chemical fertilizer pesticides,
fungicides hormones & maintaining the plants uo
to three months as deserted Trinagle Plan.
173 Bowing and developing flowering plants grown 10.00 No. 60.60
in nusery having approximate height 4 to 5 ft or
Height ad per Landscaps Plan with natural
growith and nature colour planted in alump of
soil packed in polithyline bag or Earthern pot.
Including organic & chemical fertilizer pesticides,
fungicides hormones & maintaining the plants uo
to three months as Jasud
174 Bowing and developing flowering plants grown 10.00 No. 75.75
in nusery having approximate height 4 to 5 ft or
Height ad per Landscaps Plan with natural
growith and nature colour planted in alump of
soil packed in polithyline bag or Earthern pot.
Including organic & chemical fertilizer pesticides,
fungicides hormones & maintaining the plants uo
to three months as Croton
175 Bowing and developing flowering plants grown 8.00 No. 10.10
in nusery having approximate height 4 to 5 ft or
Height ad per Landscaps Plan with natural
growith and nature colour planted in alump of
soil packed in polithyline bag or Earthern pot.
Including organic & chemical fertilizer pesticides,
fungicides hormones & maintaining the plants uo
to three months as deserted green mahindi
Item Description of Item Quantity Unit Rate In Amount
176 Bowing and developing flowering plants grown 8.00 No. 15.15
in nusery having approximate height 4 to 5 ft or
Height ad per Landscaps Plan with natural
growith and nature colour planted in alump of
soil packed in polithyline bag or Earthern pot.
Including organic & chemical fertilizer pesticides,
fungicides hormones & maintaining the plants uo
to three months as deserted New block ficus.
177 Labour charges for planting various plantsafter 56.00 No. 40.40
proper anti termite treatment in pits including
placing property and filling the pit with requred
prepared mix soil and wetering and dispporting
178 Maintance of the garder for 360 days after 1.00 Job. 10100.00
Complition of 3 month stipulated period is
completed for plantation o lawn and plants
including applying second round of proper
antitermite tretment.
179 Providnig and fixing to wall ceiling and floor 80 125.00 Rmt 447.72
Schedule Syntex / Astra (CPCV) or equivalent of
the following nominal bore tube fittings and
clamps the wall ceiling and floor (C) 40 mm
180 Providing and fixing consealed to wall, ceiling 90.00 Rmt 208.80
and floor 80 Schedule Syntex / Astral (CPVC) or
equivalent brand of the following nominal bore
tube fittings and clamps including Making goods
the wall ceilling and floor (A) 20 mm
181 Providing and fixing brass screw doen stop cock 1.00 Rmt 287.85
(A) 15 mm. Dia.
182 Rubber Hose pope 15 mm dia of approved brand 120.00 Rmt 25.25
183 Providnig and fixing G I Nipple as directed. 1.00 No. 20.20
184 Supply. installation, testing & commissioning of 1.00 No 116150.00
ISI approved electrical motor driven jockey
pump set having 10.8 m3/hr. @ 70m head. The
pump unit shall be a horizontally direct mounted
motor. Unit shall comprise the following
minimum requirements:
a) Pump, b) Electric motor IE2, c) Foundation
bolts, d) Mating flanges with gasket and
fasteners, e) Discharge gauges, etc. complete in
all respect, with labour, with GST.
185 Supply, installation, testing & commissioning of 1.00 No 60600.00
Priming tank,HDPE type, 1000 litres, with
necessary piping 100 mm size, G.I pipe for
priming the pumps, pipe of with butterfly valves
for isolation, Water Filling to priming tank by
piping min. 50 mm size, ,with all complete.
Item Description of Item Quantity Unit Rate In Amount
186 Supply, fabrication & erection of aboveground 75.00 Mtr 469.65
G.I. 'C'-Class, ERW piping, conforming to IS:1239,
part-I, Heavy class up to 150 mm dia. and
IS:3589, for size 200 mm dia. & above, thickness.
G.I. pipe fitting's as per IS: 1239, part-II, Heavy
class for size 150 mm dia. & below & IS:
for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the
system pressure, hook-up etc.
Painting for piping, fittings & structural pipe
support, shall be two coat of zinc primer and
two coats of fire red conf. to IS: 5, Shade
Complete with all accessories as per approved
drawings, specicification and direction of the
Engineer-in-Charge, with all complete. 25 mm
187 Supply, fabrication & erection of aboveground 50.00 Mtr 757.50
G.I. 'C'-Class, ERW piping, conforming to IS:1239,
part-I, Heavy class up to 150 mm dia. and
IS:3589, for size 200 mm dia. & above, thickness.
G.I. pipe fitting's as per IS: 1239, part-II, Heavy
class for size 150 mm dia. & below & IS:
for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the
system pressure, hook-up etc.
Painting for piping, fittings & structural pipe
support, shall be two coat of zinc primer and
two coats of fire red conf. to IS: 5, Shade
Complete with all accessories as per approved
drawings, specicification and direction of the
Engineer-in-Charge, with all complete. 50 mm
Item Description of Item Quantity Unit Rate In Amount
188 Supply, fabrication & erection of aboveground 25.00 Mtr 1388.75
G.I. 'C'-Class, ERW piping, conforming to IS:1239,
part-I, Heavy class up to 150 mm dia. and
IS:3589, for size 200 mm dia. & above, thickness.
G.I. pipe fitting's as per IS: 1239, part-II, Heavy
class for size 150 mm dia. & below & IS:
for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the
system pressure, hook-up etc.
Painting for piping, fittings & structural pipe
support, shall be two coat of zinc primer and
two coats of fire red conf. to IS: 5, Shade
Complete with all accessories as per approved
drawings, specicification and direction of the
Engineer-in-Charge, with all complete. 80 mm
189 Supply, fabrication & erection of aboveground 100.00 Mtr 1994.75
G.I. 'C'-Class, ERW piping, conforming to IS:1239,
part-I, Heavy class up to 150 mm dia. and
IS:3589, for size 200 mm dia. & above, thickness.
G.I. pipe fitting's as per IS: 1239, part-II, Heavy
class for size 150 mm dia. & below & IS:
for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the
system pressure, hook-up etc.
Painting for piping, fittings & structural pipe
support, shall be two coat of zinc primer and
two coats of fire red conf. to IS: 5, Shade
Complete with all accessories as per approved
drawings, specicification and direction of the
Engineer-in-Charge, with all complete. 100 mm
Item Description of Item Quantity Unit Rate In Amount
190 Supply, fabrication & erection of aboveground 8.00 Mtr 2979.50
G.I. 'C'-Class, ERW piping, conforming to IS:1239,
part-I, Heavy class up to 150 mm dia. and
IS:3589, for size 200 mm dia. & above, thickness.
G.I. pipe fitting's as per IS: 1239, part-II, Heavy
class for size 150 mm dia. & below & IS:
for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the
system pressure, hook-up etc.
Painting for piping, fittings & structural pipe
support, shall be two coat of zinc primer and
two coats of fire red conf. to IS: 5, Shade
Complete with all accessories as per approved
drawings, specicification and direction of the
Engineer-in-Charge, with all complete. 150 mm
191 Supply, installtion, testing & commissioing of 35.00 Mtr 2383.60
Underground GI (ERW) piping conforming to
IS:1239, part-I, Heavy class ('C' class) up to
mm dia. and IS:3589 Heavy class ('C' class), for
200 mm dia. & above, min. 6.35mm thickness
including Heavy class fittings, anti-corrosive tape
of size 150 mm wide x 4 mm thick, wrapping &
coating with 13KV holiday testing . Rates shall
include sand bedding of 75mm dia all around,
backfilling of the excavated including installation
of heavy pipe fitting's, flanges, etc.
10 % of all the welded joints shall be done
radiographically tested and 50% of the joints
radiographed shall be the "Field Joints".
Hydrostatic testing for 2 hours at 150% of the
system pressure, hook-up etc., complete with all
accessories as per approved drawings,
specicification and direction of the Engineer-in-
Charge, with all complete. (Road Crossing)
Item Description of Item Quantity Unit Rate In Amount
192 Supply, installtion, testing & commissioing of 6.00 Mtr 3595.60
Underground GI (ERW) piping conforming to
IS:1239, part-I, Heavy class ('C' class) up to
mm dia. and IS:3589 Heavy class ('C' class), for
200 mm dia. & above, min. 6.35mm thickness
including Heavy class fittings, anti-corrosive tape
of size 150 mm wide x 4 mm thick, wrapping &
coating with 13KV holiday testing . Rates shall
include sand bedding of 75mm dia all around,
backfilling of the excavated including installation
of heavy pipe fitting's, flanges, etc.
10 % of all the welded joints shall be done
radiographically tested and 50% of the joints
radiographed shall be the "Field Joints".
Hydrostatic testing for 2 hours at 150% of the
system pressure, hook-up etc., complete with all
accessories as per approved drawings,
specicification and direction of the Engineer-in-
Charge, with all complete. (Road Crossing)
193 Design , Supply and installation of Safety Signage 120.00 Sq. ft 1599.84
made of Zinc Sulphilde based glow in dark , Rigid
sheet with High Luminous property enclosed in a
transperent weather proof UV stabilized plastic
pasted on 3 mm thick clear acrylic sheet such as
EXITS, EMERGENCY EXIT, DO NOT USE LIFT
DURING FIRE, FLOOR MARKINGS, FIRE LIFT,
STAIRCASE EXIT, FIRE ALARM CALL POINT,
FIRE HOSE REEL, FIRE HYDRANT POINT etc.
194 Supply, installation, testing & commissioning of 3.00 No 3333.00
pressure switch. (Range 0 to 16 kg/cm2)
195 Supply, installation, testing & commissioning of 4.00 No 3232.00
150 mm dia. dial Burdon Type Glycerine Filled
pressure gauge with isolation ball valve
arrangements with necessary isolation valves
with all complete.( Range 0 to 15 kg/cm2)
196 Supply, installation, testing & commissioning of 1.00 No 6969.00
Cast iron body double flanged gate valve With
Rising Spinldle conf. to IS: 14846, PN-1.6 with
mating flanges, drilling as per IS/ANSI 150# with
mating flanges, galvanized nut, bolts & washers,
gasket 3 mm thick, etc., with all complete.
Item Description of Item Quantity Unit Rate In Amount
197 Supply, installation, testing & commissioning of 2.00 No 12120.00
Cast iron body double flanged gate valve With
Rising Spinldle conf. to IS: 14846, PN-1.6 with
mating flanges, drilling as per IS/ANSI 150# with
mating flanges, galvanized nut, bolts & washers,
gasket 3 mm thick, etc., with all complete.
198 Supply, installation, testing & commissioning of 1.00 No 18786.00
Cast iron body double flanged gate valve With
Rising Spinldle conf. to IS: 14846, PN-1.6 with
mating flanges, drilling as per IS/ANSI 150# with
mating flanges, galvanized nut, bolts & washers,
gasket 3 mm thick, etc., with all complete.
199 Supply, Installation, Testing & Commissioning of 3.00 No 2373.50
Cast iron body Butterfly valve according to IS:
13095, PN-1.6, Iron Disc for size 150 mm dia. &
below Lever operated and above 150 mm dia.
Gear operated complete with mating flanges
/ANSI class # 150 with bolts & nuts washers,
rubber gaskets 3 mm thick, etc., with all
complete. 50 mm dia.
200 Supply, Installation, Testing & Commissioning of 1.00 No 3030.00
Cast iron body Butterfly valve according to IS:
13095, PN-1.6, Iron Disc for size 150 mm dia. &
below Lever operated and above 150 mm dia.
Gear operated complete with mating flanges
/ANSI class # 150 with bolts & nuts washers,
rubber gaskets 3 mm thick, etc., with all
complete. 80 mm dia.
201 Supply, Installation, Testing & Commissioning of 3.00 No 3686.50
Cast iron body Butterfly valve according to IS:
13095, PN-1.6, Iron Disc for size 150 mm dia. &
below Lever operated and above 150 mm dia.
Gear operated complete with mating flanges
/ANSI class # 150 with bolts & nuts washers,
rubber gaskets 3 mm thick, etc., with all
complete. 100 mm dia.
202 Supply, installation, testing & commissioning of 1.00 No 6918.50
Cast iron body NRV conf. to IS: 5312, PN-1.6
complete with mating Flanges/IS/ ANSI class #
150 with bolts & nuts, washers, gaskets 3 mm
thick, etc., with all complete Accessories 50 mm
203 Supply, installation, testing & commissioning of 1.00 No 8837.50
Cast iron body NRV conf. to IS: 5312, PN-1.6
complete with mating Flanges/IS/ ANSI class #
150 with bolts & nuts, washers, gaskets 3 mm
thick, etc., with all complete Accessories 80 mm
Item Description of Item Quantity Unit Rate In Amount
204 Supply, installation, testing & commissioning of 2.00 No 10605.00
Cast iron body NRV conf. to IS: 5312, PN-1.6
complete with mating Flanges/IS/ ANSI class #
150 with bolts & nuts, washers, gaskets 3 mm
thick, etc., with all complete Accessories 100 mm
205 Supply, installation, testing & commissioning of 1.00 No 2121.00
SG iron body SinglePlate Wafer Type NRV conf.
to ASTMA 536, PN-1.6 complete with mating
Flanges class # 150 with bolts & nuts, washers,
gaskets 3 mm thick, etc., with all complete.
Accessories 100 mm dia.
206 Supply, installing, testing and commissioning of 1.00 No 4949.00
Normax make CI heavy duty ball type foot valve
with flanges, nut bolts, gaskets etc. with
necessary complete accessories. 80 mm dia.
207 Supply, installing, testing and commissioning of 2.00 No 14645.00
Normax make CI heavy duty ball type foot valve
with flanges, nut bolts, gaskets etc. with
necessary complete accessories. 150 mm dia.
208 Supply, installation, testing & commissioning of 3.00 No 6060.00
Two way fire brigade Inlet connection with
mm dia. stainless steel (SS304) instantaneous
male inlets with built in non return valve in each
inlet with 100 mm dia. header pipe, suitable
rubber cap and GI chain including nuts, bolts,
washers, gasket 3 mm thick, etc. with all
209 Supply, installation, testing & commissioning of 3.00 No 6413.50
Oblique pattern type stainless steel (SS 304)
single headed External Fire Hydrant Valve with
63 mm dia. female instantaneous outlet conf. to
IS: 5290, type - A, including mating flanges,
galvanised nuts, galvanised bolts/studs, washers
& gaskets 3 mm thick with all complete.
210 Supply, installation, testing & commissioning of 3.00 No 2070.50
63 mm dia. stainless steel (SS 304) Universal
Branch Pipe conf. to IS:
211 Supply & installation, testing & commissioing of 3.00 No 8221.40
Fire Fighting Hose - conf. to IS : 636, type A (type -
1), The fire hose shall be 15 m long with 63 mm
dia. stainless steel (SS 304) couplings conf. to IS:
903, at both the ends for connection with the
hydrant valve and the branch pipe.
Item Description of Item Quantity Unit Rate In Amount
212 Supply, installation, testing & commissioning of 3.00 No 2979.50
fabricated from 3 mm MS sheet, hose box of size-
450 mm x 600 mm x 250 mm - painted with Fire
Red as per IS: 5, shade no. 536 front 3 mm thick
transparent glass with lock & key, handle and
brass hinges - to accommodate one number of
mtr long hose and one number of universal
branch pipe, including supporting arrangement
with civil work.
213 Supply, Installation, testing & commissioing of 8.00 No 7575.00
Swinging type mild steel hose reel drum with
mm dia. x 30 mtr. rubber hose as per IS: 884. The
mounting stand shall be of mild steel and the
hose shall be fitted with a SS shut-off nozzle & SS
ball valve of 25 mm dia. including supporting
arrangement with all complete. accessories
214 Supplying, fixing & testing of of SS ball Valve 8.00 No 833.25
215 Supplying, fixing & testing of New Battery of 1.00 No 18685.00
diesel engine 150 Amp.
216 Supply and installation of Diesel Tank For Diesel 1.00 No 19695.00
Engine With All Accessories 100 Ltrs.
217 Supplying, filling & testing lube oil for diesel 10.00 Ltrs 378.75
218 Supply and commissioning of Oil Filter 1.00 No 833.25
219 Supplying, filling of diesel in diesel engine tank 50.00 Ltrs 75.75
220 Excavation of foundation, Lead And Liftting of 8.00 Cu. 6666.00
soil work and RCC work Mtrs
221 Filling Of Gaps Between pipe and Core Cutting 15.00 No 353.50
Hole With Chemical and Cement
222 Supply,fabrication and erection of Structure MS 300.00 Kg 90.90
Material as like Angle, C channel,I Beam Etc.
223 Supply, installation and commissioning of 30.00 Mtr 85.85
Flexible cable for 1.5 sq mm x 3 core for pressure
224 Supply, installation and commissioning of 12.00 Mtr 222.20
Copper Armour cable for 10 HP Motor - 4 sq mm
225 Supply, installation and commissioning of 24.00 Mtr 404.00
Copper Armour cable for 40 HP Motor - 10 sq
226 Supply, installation and commissioning of 20.00 Mtr 191.90
Copper Armour cable for Diesel Engine Battery
Charger - 2.5 sq mm x 3 Core
227 Supply, Filling and Fixing of approved make ABC 15.00 No 2323.00
type fire extinguisher - 6 Kg. Capacity as per
228 Supply, Filling and Fixing of approved make CO2 15.00 No 6514.50
type fire extinguisher. Capacity 4.5 Kg.
(conforming to IS-15683).
Item Description of Item Quantity Unit Rate In Amount
229 Submitting the application to obtain Fire NOC for 1.00 No 50500.00
one year to SMC Department,Providing complete
practical demonstration of fire system in
presence of fire officer and Submitting the
photographs of demonstration, refilling and
testing certificates of fire extinguisher,Obtaining
and providing certificate of FPCOR, Payment of
NOC Fees to SMC Department, Preparing the
documents of Affidavit and AMC with
Notorization And Submitting to Department,
follow up to receive NOC And Providing to R & B
Including all above expenditure.
230 Supply, Installation and commissioning of Fire 1.00 No 35350.00
Alarm Panel Conventional type, 8 loops , with
complete accessories.
231 Supply, Installation and commissioning of Audio 5.00 No 1262.50
hooters , with complete accessories.
232 Supply, Installation and commissioning of 5.00 No 1191.80
Manual Call Points, with complete accessories.
233 Cable(Armour) for Fire Alarm system 250.00 Mtr 111.10
234 Core cutting in wall and in RCC slab with size as 6.00 No 323.20
below: 40 mm dia. Hole
235 Core cutting in wall and in RCC slab with size as 2.00 No 444.40
below: 80 mm dia. Hole
236 Core cutting in wall and in RCC slab with size as 2.00 No 454.50
below: 100 mm dia. Hole
237 Core cutting in wall and in RCC slab with size as 4.00 No 707.00
below: 150 mm dia. Hole
238 Core cutting in wall and in RCC slab with size as 3.00 No 1010.00
below: 200 mm dia.
239 Supply, installation, testing & commissioning of 1.00 Set 161600.00
ISI approved electrical motor operated Kirloskar
make fire hydrant main pump set horizontal end
suction back pull out top discharge centrifugal
fire pump set with all the standard acessories,
base frame, coupling, and foundation bolts with
following specifications Model -DB 50/26, Flow-
54 m3/hr, Head-70 meter, Motor Rating -
22KW/30HP/3 ph Suc x Del - 65 x
240 Supplying, Installation, Testing and 1.00 No 483285.00
commissioning of Kirloskar make diesel engine
driven fire hydrant pump set suitable for
automatic operation and consisting of following:
horizontal type, centrifugal end suction back pull
out, top discharge pump of cast iron body &
bronze impeller with m.s.fabricated common
base plate, coupling, coupling guard, foundation
bolts etc.,as required. Model -KFE Flow-96
m3/hr, Head-70 meter, Engine - 50 HP / 3 ph Suc
Item Description of Item Quantity Unit Rate In Amount
241 Fire Hydrant Panel suitable for 10 hp Jockey 1.00 No 128775.00
pump, 40 hp (54 m3/hr @ 70 m head) main
electrical pump and 50 hp (96 m3/hr @ 70 m
head) Diesel engine operated pump A) Incomer
MCCB - 1 Nos R Y B Indication - 1 Set VAF Digital
Meter - 1 Set B) Outgoing F1 40 HP Star Delta
Starter - 1 For Main pump F2 10 HP DOL Starter -
1 For Jockey Pump F3 Auto - On / Off Diesel
Pump With Battery Charger Control Circuit With
Auto - Manual On/Off On/Off Trip Indication
On/Off Push Button C) Fabrication Dully Powder
Coated PO Red Colour, Fabricated From 14/16
SWG,GI Sheet , IP-42 Protection,-Fixed Type
Floor Mounted Cable Entry : Bottom
242 Providing and fixing a fire hydrant point 8.00 Nos 5555.00
installing a single-headed gunmetal fire hydrant
valve with instantaneous type coupling
conforming to IS:5290, mounted on a cast iron
hydrant stand post with flanged ends, including
necessary bolts, nuts, washers, and rubber
insertion. A mild steel fire hydrant box with a
glass front, lock, and key, painted with red
enamel paint, is also provided. The installation
includes a 30-meter long fire hose reel with a
mm diameter hose, complete with a shut-off
nozzle, drum, and wall mounting bracket, as well
as two 15-meter long fire hoses with 63 mm
diameter, complete with male and female
instantaneous type couplings conforming to
IS:636. Additionally, a gunmetal branch pipe
with a nozzle conforming to IS:903 and a 4-way
fire brigade inlet connection with gunmetal non-
return valves and instantaneous type couplings
conforming to IS:904 are installed. The system
includes mild steel pipes and fittings for the fire
hydrant system, with cutting, threading, welding,
and painting with two coats of red oxide primer
and two coats of synthetic enamel paint. Civil
works involve excavation, backfilling, and
making good the surface for laying the
underground fire hydrant pipeline, including
necessary supports and protection.
243 Providing and fixing a mild steel (MS) hose box 8.00 Nos 6565.00
with double doors, glass front, lock, and key,
painted with red enamel paint. The hose box is
wall-mounted, measures 600 mm x 450 mm x
250 mm (or as specified), and is designed to
securely house fire hoses and related equipment.
The double doors with a glass front allow for
easy visibility and access, while the red enamel
paint ensures high visibility and protection
against corrosion. The box includes a lock and
key for added security.
Item Description of Item Quantity Unit Rate In Amount
244 Providing and fixing a fire hose pipe to IS:636. 8.00 Nos 3535.00
The hose is designed for high-pressure water
delivery in firefighting applications and is made
of durable, flexible material to withstand harsh
conditions. The couplings ensure quick and
secure connections to hydrants and other
firefighting equipment, facilitating efficient water
flow during emergencies.
245 Providing and fixing a fire hose nozzle installing 8.00 Nos 1515.00
a gunmetal branch pipe with a nozzle
conforming to IS:903. The nozzle is designed for
attachment to a 63 mm diameter fire hose and is
made of durable gunmetal to ensure longevity
and resistance to corrosion. It features an
adjustable spray pattern to allow for both a
concentrated jet and a wide spray, enabling
effective firefighting in various scenarios. The
nozzle ensures efficient water flow and control,
making it an essential component of the fire
hydrant system.
246 Clearing and grubbing road land including 0.48 Hect. 28455.08
uprooting rank vegetation grass
bushes,shrubs,sapling and trees girth up to
mm removal of stumps of trees cut earlier and
disposal of unserviceable materials (C) By
mechanical means in area of light jungle
247 Earthwork in cuting in all sorts of soil and soft 64431.00 Cumt 129.28
murrum including conveying and spreading the
stuff, embankment as and where directed within
200meters from the end of the cutting with all
required lead and lift.(C) Above 400 Meters
upto 500 Meters.
248 Rolling of earthwork in layers with power roller 30337.00 Cumt 23.18
including filling in depressions which occur
during the process and Watering of earth work
249 Conveying and Utilized the stuff in the bank from 38097.00 Cumt 129.28
end of cutting with all required lead and lift ( C )
above 400 meters up to 500 meters
250 Providing and laying controlled cement concrete 380.97 Cumt 6034.75
M-250 and curing complete including the cost of
form work but excluding the cost of
reinforcement for reinforced concrete work in
251 Providing and filter media 600mm thick as 91.80 Sqmt 1268.86
directed at the back of Protection Wall as per
detailed specification.
252 Providing cement vata (10cm x 10cm size) 4.50 Rmt 24.28
quarter round in cement mortar 1:1 including
neat cement finishing watering etc. Complete
Item Description of Item Quantity Unit Rate In Amount
253 Providing and Fixing 6 mm thick Lexan 43.00 Sqm. 1441.90
Polycarbonate multi wall roofing sheet fixed with
hilti screw and rubber silicon sealer and
alluminium strip of size 50 x 3 mm etc complete
as directed by Engineer in charge.
254 Point wiring for Light/ Bell with 2-1.5 sq.mm & 725.00 Pt. 485.81
earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length, in
below type of pipe erected with 6A Modular
type switch/ bell push & accessories and earth
continuity of following type, erected on PVC/
Metallic/ Wooden box, single mounting base
frame covered with textured/ metallic/ white
front plate modules erected on/ in wall / ceiling
as per pipe erected, with necessary Lamp
holder/ ceiling rose/ H.D. Connector as directed.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete Cat. III [Accessories:- Havells
(Crabtree), MK, Schneider Electric, C&S, Achor
(Roma), Legrand ; Wire:- Finolex, Havells, RR
Cable, Polycab, KEI, Apar ; Pipe:- Precision, Nihir,
Anchor, Polycab, Vraj]
255 Point wiring for FAN with 2-1.5 sq.mm & earth 319.00 Pt. 674.68
wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 KV Grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length, in
below type of pipe erected with 6A Modular
type switch and hum free EME step type
electronic fan regulator mounted and
accessories with earth continuity of following
type erected on PVC/ Metallic/ Wooden box,
single mounting base frame covered with
textured/ metallic/ white front plate modules
erected on/ in wall/ ceiling as per pipe erected.
with necessary ceiling rose/ H.D. Connector as
directed. (f) with medium class Rigid PVC pipe
and accessories erected concealed in wall/
ceiling complete.Cat. III [Accessories:- Havells
(Crabtree), MK, Schneider Electric, C&S, Achor
(Roma), Legrand ; Wire:- Finolex, Havells, RR
Cable, Polycab, KEI, Apar ; Pipe:- Precision, Nihir,
Anchor, Polycab, Vraj]
Item Description of Item Quantity Unit Rate In Amount
256 Point wiring for Individual Plug with & earth 2.00 Pt. 510.05
wire of 1.5 sq.mm (Green) both are of ISI marked
1.1 KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type
of pipe erected complete with Modular type
switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate
front plate modules erected on / in wall / ceiling
as per pipe erected with following type of
accessories. [I] For 6A Plug and 6 a switch with 2-
1.5 sq.mm Cu. Wire from nearby
switchboard/mcb db board (f) with medium
class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete Cat. III
[Accessories:- Havells (Crabtree), MK, Schneider
Electric, C&S, Achor (Roma), Legrand ; Wire:-
Finolex, Havells, RR Cable, Polycab, KEI, Apar ;
Pipe:- Precision, Nihir, Anchor, Polycab, Vraj]
257 Point wiring for Individual Plug with & earth 3.00 Pt. 745.38
wire of 1.5 sq.mm (Green) both are of ISI marked
1.1 KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type
of pipe erected complete with Modular type
switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate
front plate modules erected on / in wall / ceiling
as per pipe erected with following type of
accessories. [II] For 16A Plug and 16 amp switch
with 2-2.5 sq.mm Cu. Wire from mcb db board.(f)
with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete Cat. III [Accessories:- Havells
(Crabtree), MK, Schneider Electric, C&S, Achor
(Roma), Legrand ; Wire:- Finolex, Havells, RR
Cable, Polycab, KEI, Apar ; Pipe:- Precision, Nihir,
Anchor, Polycab, Vraj]
258 Point wiring for on board Looped Plug with 6A 129.00 Pt. 257.55
Modular type switch & 5 pin socket erected on
PVC / Metallic/Wooden box, single mounting
base frame covered with textured /
metallic/white front plate modules erected on
/ in wall / ceiling with following type accessories
Cat. III [Accessories:- Havells (Crabtree), MK,
Schneider Electric, C&S, Achor (Roma), Legrand ;
Wire:- Finolex, Havells, RR Cable, Polycab, KEI,
Apar ; Pipe:- Precision, Nihir, Anchor, Polycab,
Item Description of Item Quantity Unit Rate In Amount
259 Providing following type of Modular Type 19.00 Ea. 151.50
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge. (1)One No. SP 6 Amp. Cat.III
[Accessories:- Havells (Crabtree), MK, Schneider
Electric, C&S, Achor (Roma), Legrand]
260 Providing following type of Modular Type 19.00 Ea. 151.50
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge. (2) One No 5 pin plug Cat.III
[Accessories:- Havells (Crabtree), MK, Schneider
Electric, C&S, Achor (Roma), Legrand]
261 Providing following type of Modular Type 216.00 Ea. 25.25
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge. (7) Blank Plate Single, Cat.III
[Accessories:- Havells (Crabtree), MK, Schneider
Electric, C&S, Achor (Roma), Legrand]
262 Providing following type of Modular Type 13.00 Ea. 180.79
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge. (9) 16 Amp. SP one way
switch Cat.III [Accessories:- Havells (Crabtree),
MK, Schneider Electric, C&S, Achor (Roma),
263 Providing following type of Modular Type 37.00 Ea. 199.98
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge. (10) 6/16Amp. Universal
socket Cat.III [Accessories:- Havells (Crabtree),
MK, Schneider Electric, C&S, Achor (Roma),
Item Description of Item Quantity Unit Rate In Amount
264 Providing following type of Modular Type 24.00 Ea. 410.06
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge. (14) 6A/ 10A/ 16A/ 20A/
25A/ 32A Double Pole Modular MCB Switch
[Accessories:- Havells (Crabtree), MK, Schneider
Electric, C&S, Achor (Roma), Legrand]
265 Providing following type of Modular Type 126.00 Ea. 160.59
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge. (8) Computer RJ-45 socket
[Accessories:- Havells (Crabtree), MK, Schneider
Electric, C&S, Achor (Roma), Legrand]
266 Providing and erecting ISI mark Medium class 3810.00 Mtr. 24.24
RIGID PVC PIPES of following size complete to be
erected on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed
(a)20 mm [Pipe:- Precision, Nihir, Anchor,
267 Supplying and laying UPVC cable trunking 48.00 Mtr. 277.75
system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and
flame proof confirming BS with necessary end
caps Internal and external bend, flat bends,
coupler, tee etc..All necessary accessories and
measuring of following sizes (1) 75 mm x 50 mm
268 Providing and erecting Mains with 1.1 KV grade 3444.00 Mtr. 82.82
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling,
with 1.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth
continuity of following size (A) With medium
class Rigid PVC pipe and accessories (b) 2 wire
2.5 sq. mm [Wire:- Finolex, Havells, RR Cable,
Polycab, KEI, Apar ; Pipe:- Precision, Nihir,
Anchor, Polycab, Vraj]
Item Description of Item Quantity Unit Rate In Amount
269 Providing and erecting Mains with 1.1 KV grade 480.00 Mtr. 112.11
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of
following size (A) with medium class Rigid PVC
pipe and accessories (a) 2 wire 4 sq. mm [Wire:-
Finolex, Havells, RR Cable, Polycab, KEI, Apar ;
Pipe:- Precision, Nihir, Anchor, Polycab, Vraj]
270 Providing and erecting Mains with 1.1 KV grade 30.00 Mtr. 147.46
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of
following size (b) 2 wire 6 sq. mm [Wire:-
Finolex, Havells, RR Cable, Polycab, KEI, Apar ;
Pipe:- Precision, Nihir, Anchor, Polycab, Vraj]
271 Providing and erecting Mains with 1.1 KV grade 540.00 Mtr. 260.58
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of
following size (h) 4 wire 6 sq. mm [Wire:-
Finolex, Havells, RR Cable, Polycab, KEI, Apar ;
Pipe:- Precision, Nihir, Anchor, Polycab, Vraj]
272 Supplying & erecting approved make LAN cable 2520.00 Mtr. 47.47
of following size in existing pipe as per direction,
[C] CAT - 6 [Make:- D-link, Havells, RR Cable, KEI,
273 Providing and erecting Mains with ISI marked, 228.00 Mtr. 56.56
1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected
in existing pipe of following size (Specifically for
control panel, relays, power switchgears, motor
starters & control wiring) with required size of
copper lugs, nuts and bolts if required. (e) One
wire 6.00 sq. mm [Wire:- Finolex, Havells, RR
Cable, Polycab, KEI, Apar]
Item Description of Item Quantity Unit Rate In Amount
274 Providing and erecting Mains with ISI marked, 56.00 Mtr. 300.98
1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected
in existing pipe of following size (Specifically for
control panel, relays, power switchgears, motor
starters & control wiring) with required size of
copper lugs, nuts and bolts if required. (i) One
wire 35.00 sq. mm [Wire:- Finolex, Havells, RR
Cable, Polycab, KEI, Apar]
275 Supplying and erecting Flexible PVC insulated 2242.00 Mtr. 22.22
multi strand multi core 1.1 kv grade ISI marked
copper wires of following size to be erected as
directed. (c) 1.00 Sq.mm 2 core round/ flat PVC
sheathed [Wire:- Finolex, Havells, RR Cable,
Polycab, KEI, Apar]
276 Supplying and erecting Flexible PVC insulated 248.00 Mtr. 46.46
multi strand multi core 1.1 kv grade ISI marked
copper wires of following size to be erected as
directed. (e) 1.50 Sq.mm 3 core round PVC
sheathed [Wire:- Finolex, Havells, RR Cable,
Polycab, KEI, Apar]
277 Providing & erecting Switch board for 126.00 Ea. 1133.22
Computer or electric apparatus consisting of
following modular type accessories mounted
with PVC / Metallic concealed/open box with
single mounting base frame covered with
textured/metallic /white front plate,modules
erected with necessary connections as directed,
1 no. 6A/16A universal plug-switch combined.
nos. 6A Switch, 3 nos. 6A 5 pin Plug, For Modular
Type Accessories Cat. III [Accessories:- Havells
(Crabtree), MK, Schneider Electric, C&S, Achor
(Roma), Legrand]
278 Decorative call bell Ting-tong box type 250 volts 2.00 Ea. 71.71
complete erected
Item Description of Item Quantity Unit Rate In Amount
279 Supplying and erecting LED indoor fittings with 588.00 Ea. 535.30
LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion
resistance with diffuser with company
mark/name 160V to 270V, Power Factor more
than 0.95, THD < 15%, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED driver
efficiency > 85 % (fitting required LM-79 & LM-
80 Certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A)
Tube Light with integral driver (v) 36-40 Watts,
Surge-2 KV, IP-20, conventional 4 feet Cat-lll
[Make:- Phillips, Crompton, Havells, Wipro,
280 Supplying and erecting led lamps with following 24.00 Ea. 112.11
wattage capacity of 220 to 240 voltage, minimum
15000 burning hours life, 500 V in built-surge
protection,Polycarbonate diffuser, mounting
suitable for E14 / E27 / B22 lamp holders, pf >=
0.5 (A) LED Lamps integral type, with PC diffuser
suitable LAMP holder (ii) 5 to 8 watts Cat-III
[Make:- Phillips, Crompton, Havells, Wipro,
281 Supplying and erecting LED indoor fittings with 68.00 Ea. 1794.77
LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. &
corrosion resistance with diffuser housed in
aluminium casted body with company
mark/name 160V to 270V,Power Factor more
than 0.95, THD < 15 %, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , LED driver
efficiency > 85 % ( fitting required LM-79 & LM-
80 Certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (B)
LED Panel Light with provision for Plane front
frame with translucent cover fixed to housing
complete.IP20 (vi) 36 watts, 24" x 24", Surge-
2KV Cat-lll [Make:- Phillips, Crompton, Havells,
Wipro, Jaquar, Bajaj]
Item Description of Item Quantity Unit Rate In Amount
282 Supplying and erecting LED street light / Flood 39.00 Ea. 5976.17
light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and
corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than
5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver efficiency
> 85 %. (fittings required LM-79 & LM-80
certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A)
Street Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC line supply
with over-voltage protection. (iii) Above 60 to
90 watts Cat-lll [Make:- Phillips, Crompton,
Havells, Wipro, Jaquar, Bajaj]
283 Supplying and erecting LED street light / Flood 10.00 Ea. 9647.52
light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and
corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or
embossed 160 to 270 V, Power Factor more than
Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt. LED driver efficiency > 85 %.
(fittings required LM-79 & LM-80
certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC line supply
with over-voltage protection. (vii) (vi)above
to 200 watts Cat-lll [Make:- Phillips, Crompton,
Havells, Wipro, Jaquar, Bajaj]
Item Description of Item Quantity Unit Rate In Amount
284 Supplying and erecting LED street light / Flood 4.00 Ea. 4819.72
light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and
corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than
5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
(C) Post Top Lantern LED fitting comprises of
finish cast aluminum spigot and spun aluminum
canopy fixed with opal polycarbonate, pipe
arrangement for vertical mounting driver and
accessories wired upto terminal block.IP
(ii)32-40W Cat-lll [Make:- Phillips, Crompton,
Havells, Wipro, Jaquar, Bajaj]
285 Pproviding and erecting Approved make Four 1.00 Ea. 6173.12
pole moulded case circuit breaker having
breaking capacity ICU of 25 KA. at 415 V,having
normal current rating up to 25 A to 100A. with
Fixed thermal & magnetic release suitable to
work on A.C. supply 50 c/s. with all internal
connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing. ICS=100%
of ICU only Cat III [Make:- L&T, Hager, Havells,
C&S, Siemens, Legrand, Schneider Electric]
286 Providing and erecting Approved make Four 5.00 Ea. 8055.76
pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. at 415 V. having
normal current rating 125A. with Fixed thermal
& magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in
existing 16 G.M.S. housing. ICS=100% of ICU
Item Description of Item Quantity Unit Rate In Amount
287 Providing and erecting Approved make Four 3.00 Ea. 16221.61
pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. at 415 V. having
Normal current rating 200A.with variable
Thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in
existing 16 G.M.S.housing ICS=100% of ICU only,
Cat III [Make:- L&T, Hager, Havells, C&S, Siemens,
Legrand, Schneider Electric]
288 Providing and erecting Approved make Four 2.00 Ea. 20946.39
pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. and above at
V . having normal current rating 250A. with
variable thermal & magnetic release suitable to
work on A.C.supply 50 c/s. with all internal
connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing. ICS=100%
of ICU only, Cat III [Make:- L&T, Hager, Havells,
C&S, Siemens, Legrand, Schneider Electric]
289 Supplying & erecting approved make Four Pole 1.00 Ea. 13353.21
415V change over switch interior for panel
mounting with operating mechanism A.C.23 duty
confirming to IS for (E)250A / 320A Cat-lll
[Make:- L&T, Hager, Havells, C&S, Siemens,
Legrand, Schneider Electric]
290 Supplying and erecting triple pole & neutral 2.00 Rn. 1961.42
440V / 500V panel mounting Copper Busbars Mtr
with four equal Nos. of electrolyte bus having
current density not more than 1.6 Amp. / sq.mm
(Rated current / cross section area) duly
wrapped with colour insulating tape for phase
sequence of following current carrying capacity,
erected with necessary bus bar supports
/insulators, main cable socket to each bar,
erected in existing cubical panel with necessary
connections. (A) Suitable for 100 Amp. Capacity
291 Supplying and erecting triple pole & neutral 1.00 Rn. 3202.71
440V / 500V panel mounting Copper Busbars Mtr
with four equal Nos. of electrolyte bus having
current density not more than 1.6 Amp. / sq.mm
(Rated current / cross section area) duly
wrapped with colour insulating tape for phase
sequence of following current carrying capacity,
erected with necessary bus bar supports
/insulators, main cable socket to each bar,
erected in existing cubical panel with necessary
connections. (B) Suitable for 200 Amp. capacity
Item Description of Item Quantity Unit Rate In Amount
292 Supplying and erecting triple pole & neutral 1.00 Rn. 4909.61
440V / 500V panel mounting Copper Busbars Mtr
with four equal Nos. of electrolyte bus having
current density not more than 1.6 Amp. / sq.mm
(Rated current / cross section area) duly
wrapped with colour insulating tape for phase
sequence of following current carrying capacity,
erected with necessary bus bar supports
/insulators, main cable socket to each bar,
erected in existing cubical panel with necessary
connections. (C) Suitable for 300 Amp. capacity
293 Providing and erecting Miniature circuit breaker 224.00 Ea. 112.11
single pole 6A to 25A suitable to operate on
V A.C. system and having breaking capacity
KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat.III [Make:- L&T,
Hager, Havells, C&S, Siemens, Legrand, Schneider
294 providing and erecting Miniature circuit breaker 53.00 Ea. 270.68
single pole 0.5A to 2A system and having
breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark
[Make:- L&T, Hager, Havells, C&S, Siemens,
Legrand, Schneider Electric]
295 Providing & erecting 240 V MCB double pole 1.00 Ea. 278.76
switch for lighting Load (B Curve) having 10 KA
breaking capacity & confirms to IS : 8828 in
existing box having following capacity (A) 6 to
Amp. Cat.III [Make:- L&T, Hager, Havells, C&S,
Siemens, Legrand, Schneider Electric]
296 Providing & erecting 240 V MCB double pole 4.00 Ea. 295.93
switch for lighting Load (B Curve) having 10 KA
breaking capacity & confirms to IS : 8828 in
existing box having following capacity (B)
Amp. Cat.III [Make:- L&T, Hager, Havells, C&S,
Siemens, Legrand, Schneider Electric]
297 Providing & erecting 415V MCB Four Pole Switch 48.00 Ea. 638.32
for Lighting Load (B curve) having 10KA
breaking capacity & confirms to IS :8828 in
existing box having following capacity (b)40
Amp. Cat.III [Make:- L&T, Hager, Havells, C&S,
Siemens, Legrand, Schneider Electric]
298 Sheets steel powder coated enclosure suitable 3.00 Ea. 176.75
for incorporating One/ Two nos. MCB. [Make:-
L&T, Hager, Havells, C&S, Siemens, Legrand,
Schneider Electric]
Item Description of Item Quantity Unit Rate In Amount
299 Providing and erecting Sheet Steel powder 2.00 Ea. 1492.78
coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house appropriate
nos. of MCBs.(The DBs should be used of same
company of MCB to be used) suitable for (A)
single phase incoming and horizontal single
phase outgoing (b) sheet steel double door (IP-
43) (iv)12 way [Make:- L&T, Hager, Havells, C&S,
Siemens, Legrand, Schneider Electric]
300 Providing and erecting Sheet Steel powder 18.00 Ea. 2339.16
coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house appropriate
nos. of MCBs.(The DBs should be used of same
company of MCB to be used) suitable for (B)
three phase incoming and single phase
horizontal type outgoing Per phase isolation
type (PPI) (b) sheet steel double door (i)4 way
[Make:- L&T, Hager, Havells, C&S, Siemens,
Legrand, Schneider Electric]
301 Providing and erecting Approved make RCCBs 4.00 Ea. 1969.50
conforming to IS: 12640 and having sensitivity of
30 mA and Short Circuit withstand capacity of
KA and suitable for operation on single phase
240 V,50Hz. having characteristic of quick action
& tripping with all advance feature & do not
incorporate any electronic component. for
following Max. rating erected as directed (i)
Amps.DP Cat. III [Make:- L&T, Hager, Havells,
C&S, Siemens, Legrand, Schneider Electric]
302 Providing and erecting Approved make RCCBs 55.00 Ea. 2235.13
conforming to IS: 12640 and having sensitivity of
30 mA and Short Circuit withstand capacity of
KA and suitable for operation on single phase
240 V,50Hz. having characteristic of quick action
& tripping with all advance feature & do not
incorporate any electronic component. for
following Max. rating erected as directed (ii)
40Amps. DP Cat. III [Make:- L&T, Hager, Havells,
C&S, Siemens, Legrand, Schneider Electric]
303 Providing and erecting Annealed bare Copper 25.00 Kg. 794.87
wire 8 to 16 SWG.
304 Providing and erecting HOT deep Galvanised 42.00 Kg. 77.77
iron strip wire 8 to 16 SWG.
Item Description of Item Quantity Unit Rate In Amount
305 Providing and erecting Pipe type earthing having 21.00 Ea. 368.65
150 cms.long and 2.5 cms. dia. galvanised iron
pipe with coupling and buch buried in specially
prepared earth pit complete with necessary
SWG earth wire.
306 For using salt and charcoal / coke as required for 21.00 Ea. 171.70
pipe type earthing.
307 Supplying & erecting earth pit of minimum bore 4.00 Ea. 4591.46
dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm
having 80-200 Micron galvanising, Inner pipe dia
of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant
ohmic value surrounded by highly conductive
compound with high charge dissipation suitable
for following type of applications with chamber
and heavy duty cover. (A)(approved make OEM
has to submit test certificate including value of
earth resistance of installation duly stamped and
signed by agency and officer Incharge has to
ensure the value of earthing resistane mentioned
in test Certificate) & having back filling
compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing
as per IEC 62561-2017, Voltage drop:- < 1 volt at
no load & dry form, Sulphar content:- <2%(C)
Back fill Compound :- Earthing compound
should be capable to retain moisture for long
time Necessary test report must be submitted by
Agency. (a) For Electrical Installation up to 440V
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
308 Providing , erecting , fabricating the M.S. 110.00 Kg. 77.77
structure as per requirement on site
incorporating proper size of M.S.
angles,square,round, flats, bars, channels,
sections complete with cutting, welding, grinding
& finishing duly painted with one coat of red
oxide with erection on site as per direction of
engineer in charge with necessary grouting,
cementing, plastering & finishing complete.
Item Description of Item Quantity Unit Rate In Amount
309 Providing & erecting weather proof, dust & 6.00 Sq. 10468.65
vermin proof, floor mounted front operated Mtr
indoor type cubical panel board necessary IP-42
and above protection as per approval from
engineer incharge made from 14 SWG thick CRC
M.S. sheet for outer body & doors, 16 SWG thick
CRC M.S.sheet for internal partitions with
necessary accesories , supporting angles/ flats
channel including cutting, bending, drilling,
welding, riveting with internal partitions & cable
alley as per requirements & instruction of
engineer-in-charge with erection of supplied
switch gears, BUSBARS, suitable size of inter
connecting PVC copper wire / copper-aluminium
strips, rubber grommets, rib, bakelite control
fuses/MCB for measuring instruments, earth bus
& earth bolts, foundation flange - bolts-base
Plates, sufficient nos. of hinged doors, handles
with locking arrangement and rubber
gasket,heavy duty end terminal
connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel
shall be painted with epoxy powder coating. (The
rates excludes the cost of switchgears, bus bars,
inter connecting mains & Copper Aluminium
strips, meters, Fuses etc. The dimension shall be
measured excluding base beams) The panel shall
be supplied with following approved
manufacturers with following size. (A) locally
310 Providing and erecting XLPE(IS:7098)(I)-88 ISI 40.00 Mtr. 92.92
armoured cable Aluminium conductor for
KV. to be laid on wall with necessary clamps or
in existing trench / pipe of following size of
cables. (B) 2 core 6 Sq. mm [Make:- Havells, KEI,
Finolex, RR Cable, Polycab, Apar]
311 Providing and erecting XLPE(IS:7098)(I)-88 ISI 28.00 Mtr. 490.86
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables (E) 3 1/2 core 95 Sq.
mm ( 50 Sq. mm 1/2 core) [Make:- Havells, KEI,
Finolex, RR Cable, Polycab, Apar]
312 Providing and erecting XLPE(IS:7098)(I)-88 ISI 210.00 Mtr. 540.35
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables (F) 3 1/2 core 120 Sq.
mm ( 70 Sq. mm 1/2 core) [Make:- Havells, KEI,
Finolex, RR Cable, Polycab, Apar]
Item Description of Item Quantity Unit Rate In Amount
313 Providing and erecting XLPE (IS:7098)(I)-88 ISI 1040.00 Mtr. 126.25
armoured cable multistrand / Solid Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables (B) 4 core 6 Sq. mm
[Make:- Havells, KEI, Finolex, RR Cable, Polycab,
314 Providing and erecting XLPE (IS:7098)(I)-88 ISI 40.00 Mtr. 153.52
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables (A) 4 core 16 Sq. mm
[Make:- Havells, KEI, Finolex, RR Cable, Polycab,
315 Making trench in soft soil of suitable width of 90 758.00 Mtr. 55.55
cm deep for laying cable or locating the fault all
over the run and back filling the same and
making the surface as normal ground.
316 Supplying following size of Light duty “A” Class 50.00 Mtr. 300.98
G.I . Pipe & erecting as directed by Engineer-in-
charge. (B) 50 mm dia
317 Supplying following size of Light duty “A” Class 20.00 Mtr. 696.90
G.I . Pipe & erecting as directed by Engineer-in-
charge. (D) 100 mm dia.
318 Providing & laying approved make Double 588.00 Mtr. 62.62
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same
material at required depth in existing trench for
laying of cable. below ground / road surface for
enclosing cable (A)50 mm outer dia
319 Providing & laying approved make Double 120.00 Mtr. 137.36
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same
material at required depth in existing trench for
laying of cable. below ground / road surface for
enclosing cable (D)120 mm outer dia.
320 Providing and, fixing heavy duty flange type 21.00 Ea. 38.38
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out
going tails, insulating tape etc for following size
of cables. (B) 2 to 4 core 6 Sq. mm
321 Providing and, fixing heavy duty flange type 4.00 Ea. 131.30
brass double compression type cable gland with
rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc
for following size of cables. (D) 3 & 1/2 core
Item Description of Item Quantity Unit Rate In Amount
322 Providing and, fixing heavy duty flange type 6.00 Ea. 140.39
brass double compression type cable gland with
rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc
for following size of cables. (E) 3 & 1/2 core
323 Solder less crimping type Aluminium lugs 4.00 Ea. 20.20
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
manner. (D) 35/50 Sq.mm.
324 Solder less crimping type Aluminium lugs 2.00 Ea. 25.25
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
manner. (E) 70 Sq.mm.
325 Solder less crimping type Aluminium lugs 18.00 Ea. 40.40
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
manner. (F) 95 Sq.mm.
326 Solder less crimping type Aluminium lugs 20.00 Ea. 45.45
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
manner. (G) 120 Sq.mm.
327 Supply, Installation, Testing and Commissioning 319.00 Ea. 2629.03
of suitable sweep, BEE 5 Star rated, Ceiling fan
with Brush Less Direct Current (BLDC)
permanent ferrite magnet Motor, class of
insulation: B, Rust free 3 nos.Aluminium blades,
2 nos. canopies, shackle kit with earthing
provision, copper winding, Power factor not <
0.9, Service Value (CMM/W) minimum 6.85, Air
delivery minimum 215 CMM, 350 RPM,230v
(tolerance as per IS : 374-2019), THD < 10%,
compitible with electronic regulator unit for
Speed Control and all remaining accessories
including safety pin, nut bolts, washers,
temperature rise = 75 degree C (Max.), suitable
for 140 to 285 Voltage and rectifier circuit with
surge, over current and overload protection ,
Hz, Single phase AC Supply, earthing etc.
Complete as required.[ Make shall be approved
by Engineer in Charge] (A) 1200 mm Sweep
(48") [make:- Crompton, Bajaj, Usha, Havells,
Item Description of Item Quantity Unit Rate In Amount
328 Supplying and erecting 19 / 20 mm. nominal 319.00 Mtr. 108.07
bore Medium Class M.S. Pipe down rod erected
duly painted for fan complete with proper
insulation without leakage and earthing.
329 Supplying & erecting fan hook box of 10 mm 319.00 Ea. 108.07
M.S. round bar bounded to the RCC bars up to
50mm length each side and pierced through a
16 Gauge M.S. box / Heavy Duty PVC box
complete erected concealed in Ceiling with
necessary finishing.
330 Providing 2.5mm.thick laminated acrylic sheet to 319.00 Ea. 18.18
cover the fan hook or Fan box.
331 Supplying & erecting approved make low noise 3.00 Ea. 1366.53
decorative exhaust fan having square frame ABS
body with inbuilt lowers & square frame. 250mm
with 1350 RPM Cat.II
332 Supplying & erecting single phase approved 40.00 Ea. 2054.34
make industrial exhaust fan suitable for medium
duty ring mounted low noise operation suitable
for medium duty having following dia size and
maximum speed in RPM [A] 305 mm dia
RPM Cat.II [Make:- Crompton, Bajaj, Usha,
Havells, Orient]
333 Supplying and erecting approved make 21.00 Ea. 8192.11
Octagonal pole made from HR sheet steel. The
pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/
2633/ 4759, suitable suspend local wind speed
with integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud
type terminal and arrangement for cable
termination to be erected With Suitable
foundation (Included) as per details given by
manufacturer considering site requirement. (D)
6 Mtr. Long 70 mm Top X 135 mm bottom dia,
mm thickness with 200mmX200mmX12mm
base plate, 4-M20 Bolts and 600mm long J-
Bolt.Approx Pole weight 59 kg [Make:- Valmont,
Bajaj, Transrail, Jindal, Utkarsh, Ambika]
334 Supplying & erecting approved make SMC press 14.00 Ea. 515.10
moulded composite FRP. loop-in, loop-out
approx. 2mm thick box complete with Bakelite
connector strip 5way(3P+N+E),DIN rail for
mounting mob & hinged doors as per
requirement having locking arrangements with
mounting clamp with nuts, bolts & washers
suitable for erection on pole with cable clamps&
earth bolt of following size of box. (B) 250mm x
200mm x 100mm [deep]
Item Description of Item Quantity Unit Rate In Amount
335 Supplying and erecting Street light pole bracket 3.00 Ea 491.87
comprising main B Class GI pipe of
cm/require outside dia. complete with suitable B
Class G.I. sleeve tubing of approx. 45cms.length
and suitable for 76.5mm/80mm/require size of
pole top having nuts and bolts for fixing the
brackets and having spread of 0.5 mtr. Length
with 110 deg.with vertical plane and suitable
welded stiffener reducer and nipple with check
nut complete painted with one coat.of Red oxide
/ PU base primer and two coats of Aluminium /
PU paint. paint with following nos of arms. [A]
Single Arm bracket 0.5 Mtr
336 Supplying and erecting Street light pole bracket 18.00 Ea 622.16
comprising main B Class GI pipe of
cm/require outside dia. complete with suitable B
Class G.I. sleeve tubing of approx. 45cms.length
and suitable for 76.5mm/80mm/require size of
pole top having nuts and bolts for fixing the
brackets and having spread of 0.5 mtr. Length
with 110 deg.with vertical plane and suitable
welded stiffener reducer and nipple with check
nut complete painted with one coat.of Red oxide
/ PU base primer and two coats of Aluminium /
PU paint. paint with following nos of arms. [B]
Double Arm Bracket 0.5 Mtr
337 Supplying & erecting IP 55 grade following size 1.00 Ea. 3595.60
section pillar fabricated from joint less M.S. Sheet
with angle iron legs made from jointless M.S.
Angle with cable clamps to be buried in ground
to have appropriate erection to work uniform
until erected with cement concrete foundation
and 45 cm high bricks work finishing with
plaster etc. hinged double door internally
supported on both side, with internal and
outside looking arrangement with look and keys
in duplicate 35 x 35 x 5 mm M.S. Angle of Two
Nos. one is welded and other with nut and bolt
for erecting Bakelite sheet. Painting the Section
Pillar inside and out side with three tank
powder coated paint. section pillar roof should
be without joint with water leakage proof &
tested as per IP 55 test & followed by IS 2147 of
1962 (B) 75 X 60 X 45 cm section pillar
fabricated from 16 Gauge MS Sheet with angle
iron legs 45 cm long made from 35 X 35 X 5 mm
thick MS angle.
338 Supplying and erecting HYLAM sheet on existing 1.00 sq. 1541.26
angle iron frame.for following thickness (D) mtr
339 Supplying and erecting nuwood 12 mm thick on 1.00 sq. 291.89
existing angle iron frame. mtr
Item Description of Item Quantity Unit Rate In Amount
340 SITC of 24 x 10/100/1000BASE-T ports 6.00 Ea. 15399.47
4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features
L2+ Static Routing
Optional “standard mode” or “surveillance
mode” management user interfacex
[Approved by Competent Authority i.e. not Below
the rank of Executive Engineer ]
341 SITC of Patch Panel Cat 6 UTP Keystone Type- 24 6.00 Ea. 4400.57
Port-Fully Loaded
[Approved by Competent Authority i.e. not Below
the rank of Executive Engineer ]
342 SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 126.00 Ea. 156.55
[Approved by Competent Authority i.e. not Below
the rank of Executive Engineer ]
343 SITC of 3LCD Lamp based projector having wxga 1.00 Ea. 33895.60
(1280x800) or better resolution with minimum
white brightness of 3800 lumens and color
brightness of 3800 lumens. The projector should
have minimum 1HDMI,1VGA input. Having
contrast ratio of 15000:1 or more. the projector
should have auto vertical key stone correction of
+/- 30 degree and Manual Horizontal of +/-30
degree. the projector should have optical lens,
throw ratio 1.30-1.56:1. Zoom Factor of 1.2. Lens
focus Manual having focal length 16.9mm to
20.28mm. projector should have features like AV
mute slide, quick corner and split function and
should support wireless functionality with
inbuilt wifi or wifi dongle. [Approved by
Competent Authority i.e. not Below the rank of
Executive Engineer] [Make:- BenQ, Epson, Boss,
344 SITC of 84 inch Self Lock MW (6 x 4) Instalock 1.00 Ea. 3379.46
Slow Retraction Screen, Aspect Ratio-4:3
[Approved by Competent Authority i.e. not Below
the rank of Executive Engineer]
345 SITC of universal Projector mounting kit, with 1.00 Ea. 6848.81
necessary grouting, fasteners etc. with adjustable
height and suitable for all types of projectors.
[Approved by Competent Authority i.e. not Below
the rank of Executive Engineer ]
Item Description of Item Quantity Unit Rate In Amount
346 Providing and erecting Inverter based approved 20.00 Ea. 80731.32
make Cassette type split air-conditioning unit
consisting of condensing unit with fan motor,
hermetically sealed scroll/rotary compressor
with accessories etc. duly connected separately
erected evaporating unit and blower motor with
its accessories by Eco friendly Green gas
charging & Internal copper wiring & Remote
control ( 3 star and above of current year) with
necessary core cutting. (B) for 2 ton capacity
[Make:- Voltas, Bluestar, Daikin, Hitachi, Carrier]
347 Supplying and erecting insulated pair of soft 192.00 RMT. 965.56
copper tubing open or concealed including
power and control cable, necessary PVC drain
pipes for Split AC machine up to 4 TR capacity
348 Supplying and erecting approved make Single 20.00 Ea. 3232.00
phase power conditioners suitable for input
voltage 180V / 280V, output voltage 220V (+ / -
10%) AC 50 ‘Hz with electronic relays &
component of housed in sheet metal cabinet
‘with epoxy powder coated, with high - low cut-
off, time delay, voltmeter, selector switch, 5/15 A
universal socket with range off (D) 4 KVA [Make:-
Gelco, V-guard, Microteck]
349 Providing & erecting water cooler having storage 3.00 Ea. 55893.40
capacity 150 Ltr. & cooling capacity 150 Ltr.per
hour @ an ambient temp of 45˚ C. The outlet
temp. of the water should drop by 15˚C within a
hour, The water cooler should be comprising of
hermetically sealed compressor, fan motor,
condensing unit, water tank surrounded by
evaporating, coil, thermostats, relay etc.complete
with necessary inlet & outlet connection. The
body of water cooler will be made from Stainless
Steel. [Make:- Voltas, Bluestar, Usha]
Item Description of Item Quantity Unit Rate In Amount
350 Supplying & erecting reverse osmosis (RO) 3.00 Ea. 77891.20
water purification system with M.S. powder
coated pedestal frame, prefilter housing carbon
filter suitable buster DC pump, auto low & high
pressure switches with following size of LPH
capacity & erected as directed [D] 100 LPH with
1 phase / 3 phase Raw water pump of 500LPH @
2.5kg/cm2 - (1N0 - Kirloskar /CRI/Lubi), Dual
media filter 10"x54" - (1 No), Micron cartridge
filter 20" x 2.5" ( 1No), High pressure pump
500LPH @ 10kg/cm2 - (1No - Shimge /CRI
/Lubi), RO Membrane housing with RO
membrane of 40*40 - (1No), RO pressure tube 4"
x 1E - ( 1No), 0 - 1200LPH Rotameter -(2 Nos),
with Recovery Rate 50%.
351 Supplying and erecting approved make panel 4.00 Ea. 1275.63
mounting type Digital Voltmeter having 3 digits
LED display, 0 to 750 AC Volts range erected on
existing panel board with all connection, wiring
etc .with manufacturers calibration certificate.
352 Supplying and erecting approved make panel 4.00 Ea. 1558.43
mounting type Digital Ammeter having 3 digits
LED display, external CT operated, calibrated for
0 to 1000 Amps suitable to operate on 500 Volt
AC , erected on existing panel board with all
connection, wiring etc .with manufacturers
calibration certificate.
353 Supplying and erecting Ammeter / Voltmeter 8.00 Ea. 317.14
selector switch for 3 phase AC Supply 500 V on
existing panel board with necessary connections.
354 Providing & erecting L.T. Current Transformer 12.00 Ea. 274.72
with bar primary 50/5 to 1000/5 ratio 15 VA
burden erected in existing CRCA box duly
secured with insulating materials connected to
355 Supplying and erecting approved make suitable 12.00 Ea. 43.43
panel indicator LED type lamp, lens cover,
complete erected with necessary connections.
Item Description of Item Quantity Unit Rate In Amount
356 Supplying & erecting Amplifier having following 1.00 Ea 11298.87
Power Output :250W (RMS) (300W Max.)
inputs : 6 Misc. & 2 Aux.
frequency Response :50-1500HZ I3db
Tone Controls :Cut & Boost type
LED Meter :5 LED Arrays
The amplifier suitable to operate 240V A.C.&
24volt D.C. (Battery) with automatic changeover
from AC to Battery operation, duly protected by
wrong Battery Polarity connections. [[Approved
by Competent Authority i.e. not Below the rank
of Executive Engineer ]
357 Supplying & erecting Booster Amplifier having 1.00 Ea. 9672.77
power output of 25OW (RMS,), suitable to obtain
combined power output of two, with 6 mike
inputs & suitable to be used independently as a
250watt amplifier in combination with mike &
mixer. The booster Amplifier shall be without
mike &Aux. input channels, The system shall be
suitable to operate on 24OV. A.C. & 24 Volts D.C.
Battery. [[Approved by Competent Authority i.e.
not Below the rank of Executive Engineer ]
358 Supplying & erecting recess wall mounting 59.00 Ea. 591.86
speaker with 5W rated input power 3.3 K. Ohms
/ 3W impedance, 100 - 10000 Hz frequency
response with 6 inch dia. cone type 8 ohms
speakers duly fitted in ABS plastic cabinet of
colour match with wall or ceiling of following
size. [[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
(b)Square shaped 260 x 260mm size speaker
359 Supplying microphones stands with sturdy 2.00 Ea 445.41
mechanism, treble free movement & positioning
of microphones, free from rust with superior
quality of chrome plating with following size.
[[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ] (c)Fixed
height 91 cms. & extendable up to 62 cms. with
round base of dia. 23 cms.
360 Supplying, installing and testing approved make 2.00 Ea. 1284.72
microphone for All purpose, with frequency
response of 100 - 11000 Hz, having sensitivity
2.2mv / Pa & impedance 500 Ohms (LO- Z)
supplied with quick detachable holder, 6 mtr
twin core cable & 3 pin XLR connector.
[[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
Item Description of Item Quantity Unit Rate In Amount
361 [1] GEAR LESS LIFT DRIVE (MRL) comprising of 1.00 Ea. 1474779.78
High Starting torque Lift 3 phase 440 V A. C.
Permanent Magnet Synchronous motor of
proper rating with high efficiency shall be
used.[2] Micro processor based / PLC, ACVVVF,
vector control drive with encoder feedback
closed loop system shall be used for lift car and
door operation which shall be full collective
selective operation hall call demand response,
UP/DOWN hall stops, Main, Up/ Down Contactor
with overload and phase reversal relay and
safety controls. [3] Car with M S platform with
bracings of adequate size and to sustain the
impact load cabin + passenger with safety factor
of fire for steel and side panels of Stainless steel
of sheet of grade 304 duty. Car ceiling will be S.S.
finishes with aesthetic appearance with LED
ceiling lights. Car flooring shall be of s/s
chaker plate design sugeested of engineer in
charge. of engineer in charge. Car doors shall be
of stainless steel grade 304, hairline finish with
centre opening / telescopic automatic doors.
Car panel will also be S.S. 304 finished with
emergency stop device, mechanical door safety
device, facility of auto/ attended mode. All car
panel buttons and all floor switches must be with
brail language as per lift act. [4] All landing doors
must be fire rated for 2 hour shall be fully
automatic centre opening/ telescopic opening
made of hairline finish steel grade of 304 with
key holes and infrared curtains with Unlocking
facility from outside
[5] Appropriate battery operated emergency
light in the car along with alarm switch shall be
provided. Also, Emergency Light & Fan should
start immediately without any Time Delay as
soon as power fails.
[6] Digital scrolling indicator system for up-
down arrow along with floor position indicator
shall be provided inside the car and at all floors.
[7] Full height infra red curtain with multiple
cross / crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be
provided accordingly of passenger capacity with
Manual Rescue Operation ( Manual Cranking
Item Description of Item Quantity Unit Rate In Amount
[9] Audio visual indication in the lift car showing
over loading shall be provided such that doors
kept open till excess load is removed. [10] Spring
buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with
automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music shall
be provided in lift car.
[13] Self diagnostics system for operational and
safety parameters shall be provided in control
[14] Mechanical over speed governor with
governor calibration as per actual site
parameters and submission of calibration
certificate submission, door key holes in the floor
doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift
machine room and monkey ladder for lift pit
should be provided by the lift agency, along with
the other steel structure works, foundations for
the machine etc…
[16] In the hoist way fascia plate shall be
provided without any extra cost, where ever
required as / if directed by engineer in charge.
[17] Permanent wiring with necessary safety
devices like RCCB in all circuit, Over Voltage
Under Voltage protection and THD eliminator in
circuit for lift machine room and lift well with
proper numbers of light points, with fixtures,
exhaust fan and plug points shall be provided by
the agency. Only 3 phase Power Supply shall be
made available by department in lift machine
room. Necessary Earthing as per Lift Act/Rules
shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional
and alteration in lift shaft and machine room
related to erection of lift shall be made by lift
agency without any extra cost. (granite/marble
fixing around all landing door openings are not
in lift agency’s scope.)
[19] Agency has to provide all working drawings
and documents and liaison services for obtaining
all necessary permission from lift inspector and
other authorities.
[20] acrylic transparent licence/display A4 size
holder in lift car
Item Description of Item Quantity Unit Rate In Amount
[20A] As per statutory requirement of Govt. Of
Gujarat lift & escalator act 2000, lift agency has
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection
during/after lift erection and provide report by
third party authorized by concern licensing
5.agency has to provide third party insurance
upto completion of free maintenance period and
submit the document for the same.
[21] Car Panel Operating Buttons with floor
position indicator/buttons must be of Auto Glow
type clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full
Length Handrails of hairline finish steel grade of
304 should be provided at appropriate height on
the Rear & Side Wall Panels in Lift Car.
[23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your controller,
drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb
required for lift is in scope of work which rating
is sugested by CEICED Department (electrical
(B) SPECIAL FEATURES DESCRIPTION OF LIFTS
for PREMIUM category
1. Advanced control system dual 64 bit
embedded microprocessor with CANBUS Serial
Communication mode including Regenerative
power efficient operation,on site programming
facility, Anti nuisance, Pte-opening, BMS/RMS
with necessary online real time monitoring
system having necessary connectivity for remote
monitoring & other suitable supporting
hardware & software devices to fulfil the
purpose. 2. Floor Indication LCD Display with
call registration & brail mark with arrival gong
and hall lantern & TFT Screen in the car with
MP3 Voice Announcer. 3. CAR Panel should be
Scratch resistive SS Moonrock finish / Hair Line /
Honeycomb for car and all Doors, All landing
doors must haveGround
10 Passengers, fire rating up2toupper
plus 2 hours andwith
Rated Speed of 1.0 m/sec., (C) With General
PLUS ADDITIONAL SPECIAL FEATURES attached
herewith. Prem. Cat. (Otis, TK Elevator,
Mitsubishi, Kone, Schindler)
Item Description of Item Quantity Unit Rate In Amount
I/We am/are willing to carry out the work at………………….% above/below percent(Should be written in figures
and words) of the estimated rate mentioned above. Amount of my /our
Tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
In words In words
The Contractor shall exhibit a board with detailed specification and details of work as directed by the
1 Engineer-In-Charge for which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-
10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items
4 where there is a change as per actual mix design the cost of difference of cement consumption have been
deducted from the rate of original item at the rate of input rate mentioned in all the tender.
The Contractor will have to submit the all required mix design at his own cost before execution as
5 directed and to be approved from the Engineer in charge.
Above all item of "Schedule-B" with item Description, Unit, Rate & Amount have verified by me
and found order.
Deputy Executive Engineer Divisional Account
( R & B ) Sub Division ( R & B ) Division
Executive Engineer
( R & B ) Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Notice_Inviting_Tender.pdf
SBD - Science Collage Limkheda.pdf
BOQ - Science Collage Limkheda.pdf
Building-Specification Booklet.pdf
Item Wise Specifications.pdf
Electrical - Science College Limkheda.pdf
GRs.pdf
P.Q. Science Collage Limkheda.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].