Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 CrAccepted-AOC | ₹1.2 Cr | 1 | Accepted-AOC first lowest |
| 2 | 2₹1.2 Cr+₹1,388.25 (0.01%)Rejected-AOC | ₹1.2 Cr+₹1,388.25 (0.01%) | 2 | Rejected-AOC second lowest |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-PRELIMINARY AGREEMENT AND AFFIDAVIT NOT SUBMITTED IN ONLINE,REGISTRATION NOT FOUND IN ORDER.HENCE REJECTED. |
Tender Value
₹1.2 Cr
EMD Value
₹50,000
Closing Date
5 Feb 2025, 4:00 pmClosed
Construction Engineer,KLDC Ltd,Thrissur
Office of the Construction Engineer, K L D C Ltd Thrissur Near Ramanilayam Guest House Thrissur-680020
App1 Solar Hanging Fence 500 m App2 Civil work for Hanging fencing 500 m App3 Chain Link Fencing 800 m App4 Farm road around check dam
2025_KLDC_731310_1
KLDC/TSR/2024-2025/4(4)
Open Tender
Civil Works - Others
Item Rate
545 days
Neriyamangalam in Ernakulam District
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,900
Yes
₹50,000
Yes
6 Jun 2025
28 Jan 2025
10 Feb 2025
28 Jan 2025
5 Feb 2025
28 Jan 2025
Amount
Supply and installation of Solar Hanging Fence -500 m
od195414/2024_2025 Supply and installation of ENERGIZER FOR HANGING FENCE With the following specifications 12V ENERGIZER, 9.9 KV output AC, input 12V DC, minimum 4 Jule must be from a reputed company, must confirm to CPRI certificate and all National and International standards of safety.<br>Switch to high, medium and low power settings. Solar panel option to recharge 12 V battery. Should possess the following output characters - Peak output voltage not more than 9.90 KV O/P energy 4 to 4.5 J minimum - Pulse duration 1.01-3.0 m.sec - Pulse interval 1.1 - 1.4 sec
od195429/2024_2025 Supply and installation of SOLAR MODULE FOR HANGING FENCE <br> Monocrystalline or polycrystalline with silicon cells with the following specification 200 watts, 12 volts rating with minimum 10 to 25 years performance warranty against manufacturing defects <br> Solar charge controller to regulate the charging of the battery - maximum charging cut off 14.2 volts and minimum 10A
od195430/2024_2025 Supply and installation of MODULE STAND WITH BOX with MS thickness tilted to 13 - 15 degrees with water proof box
od195641/2024_2025 Supply and installation of BATTERY - 100 Ah from reputed companies.
od195433/2024_2025 Supply and installation of LIGHTNING DIVERTER <br> Must be capable of diverting stray lightening. The diverter assembly must be adjustable for spark gaps; Adequate earthing to be provided.
od195434/2024_2025 Supply and installation of EARTHING SYSTEM <br> Must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rod grade 304 or above non rusting quality of 4 feet long fixing in 50x50x50 cm pit
od195435/2024_2025 Supply and installation of SUPER STRAIN INSULATER Must be of polypropylene/poly carbon material and should withstand of 16 KV
od195436/2024_2025 Supply and installation of WARNING SIGNS <br> Poly ethylene plastic with statutory colors and signs. size 50x30 cm
od195437/2024_2025 Supplying and installation of LEAD OUT CABLE <br> Must be double insulated withstanding 15 KV voltage and Inner core wire must be GI
od195438/2024_2025 Supply and installation T shaped GI square tube
od195439/2024_2025 Supply and installation of STAINLESS STEEL WIRE 1.5mm 304 grade, non rusting quality for main line
od195440/2024_2025 Supplying and installation of STAINLESS STEEL WIRE 1.2mm, 304 grade, non rusting quality for earthing line and middle line
od195441/2024_2025 Supplying and installation of BULLETS (Connectors)
od195442/2024_2025 Supplying and installation of BOTTOM FIXTURE
od195443/2024_2025 Supplying and installation of DIGITAL VOLT METER
od195322/2024_2025 TOOL KIT
od195323/2024_2025 Supplying and drawing of STAINLESS STEEL WIRE ROPE 1.5mm, 304 grade
Civil work for Hanging fencing - 500m
2.31Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
Chain link Fencing -800 m
2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
4.1.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
16.19 Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
16.70.1 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm
Farm road around check dam
60.7.2 DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
10.28 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
16.68 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
16.91.2 Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
16.78.3 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20
5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
10.25.2 Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
12.51.3 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both
51.20 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws ofsize (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required.
SAJI KURUVILA (BID ID -2091098)
Bidder Name
SAJI KURUVILA
DILJITH SABU
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1167744.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .