Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹31.5 L+₹72,272 (2.35%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹36.4 L+₹5.6 L (18.4%)Rejected-Finance 61 2 JAURASI LANDHAURA HARIDWAR 247664 UK | HARIDWAR | UTTARAKHAND | 247664 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹36.5 L+₹5.7 L (18.7%)Rejected-Finance PLOT NO 261 SHANTI KUNJ ALWAR 301415 RAJ | ALWAR | RAJASTHAN | 301415 | L4 | Rejected-Finance Being 4th lowest |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
5 Mar 2025, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
SPECIAL REPAIR OF OTM ACCN TO BLDG NO. BK-10 CAMP AREA 23/05 OF 815 FD WKSP COY (614 EME BN) AND SEPTIC TANK AND SOAKAGE WELL ALONGWITH CONNECTED SEWAGE LINE IN TCP AND JUNGLE AREA ETC UNDER AGE B/R-II AT GE CLEMENT TOWN
2025_MES_695209_1
GE /CLT / of 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class D Cat a(i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹87,200
Yes
27 May 2025
28 Jan 2025
12 Mar 2025
29 Jan 2025
5 Mar 2025
19 Feb 2025
Amount
Excavation in trenches not exec 1.5m wide and not exec 1.5m in depth for manhole, SGSW line, laying of cable, pipe line, protection pipes etc not exec 10 sqm on plan and not exec 1.5m depth and getting out to soft /loose soil complete all as specified and directed.
All as per item No. 1 above but depth exec 1.5m and n exec 3m complete all as specified and directed.
Demolition and breaking up SGSW, AC or RCC pipe 150mm dia jointed in cement mortar and taking out of trenches complete all as specified and directed.
All as per item No. 3 above but 200mm dia complete all as specified and directed.
M&L Reinforced concrete pipes, class NP2, laid and jointed complete with collars of dia 150mm laid in trenches and jointed complete all as specified and directed.
All as per item No. 5 above but 200 mm dia complete all as specified and directed.
M&L Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations or mass concrete complete all as specified and directed
M&L cement concrete bed to drain pipes of 150 mm dia type C-2 (1:3:6) including pading and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
All as per item No. 8 above but 200mm dia complete all as specified and directed.
M&L for cleaning of septic tank/soakage pit of any size, type and any depth and removing the sludge/solid content fom the septic tank/soakage pit by using honeysucker mechnical method or by using manpower including flushing with fresh water and make the septic tank/soakage pit fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab complete all as specified and directed.
Demolition of cement concrete (unreinforced) below or above ground level in any position (only haunching)
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150mm dia pipe complete all as specified and directed.
All as per item No. 12 above but 200mm dia complete all as specified and directed.
M&l brick work with sub class B bricks straight or curved on plan exec 6m mean radius built in cm (1:4) complete all as specified and directed.
M&L for honey comb brick work with sub class 'B' in one brick thick old size bricks straight or curved on plan n. exc 6m mean redius built in CM 1:4 complete all as specified and directed
M&L for loose filling of broken brick bats of gauge 80 to 150 mm as in soakage pits, soakage wells complete all as specified and directed
M&L 15mm thick rendering in cm (1:4) finished even and smooth without using extra cement complete all as specified
M&L form work to soffits of suspended slab such as roof slab and similar work n. exc 200mm thick (horizental or sloping) rough finished flat surface complete all as specified and directed
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n. exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n. exc 20 cm wide complete all as specified and directed
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping including necessary form work complete all as specified and directed
M&L TMT bars 8mm dia, cut to length bent to shape required including cranking, bending spirally for hoping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia quality confirming complete all as specified and directed.
All as per item No.21 above but 10mm dia over complete all as specified and directed.
M&L providing reinforcement cement concrete for slabs supported on walls and similar work type B-1 (1:2:4) using 20mm graded aggregate set in cement mortar (1:4) complete all as specified and directed.
Removing of excavated material/broken SGSW pipe not exec 100 m and depositing where directed at a level not exec 1.5 m above the starting point complete all as specified and directed.
Returning , filling in including spreading , levelling, watering and well ramming in layers not exec 25cm of soil complete all as specified and directed.
M&L for Septic tank, excavation in soft/loose soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame Vent shaft and sludge chambers etc., complete for 300 users all as shown in drawing complete all as specified and directed. (Refer drg No. CBBZ, TD/217, sheet 3/7)
M&L for Soakage wells exc in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber,screen chamber Brick work in CM, RCC cover slab in M-25/ RR masonry / filling with brick bats, complete of size 3.6 m dia X 3.0 m deep all as shown in drawing complete all as specified and directed. (Refer drg No. CBBZ TD No-399, sheet 3/4.)
M&L for 75mm dia cast iron soil, waste and vent pipe spun pipes any length with or without ears with cement joints fixed to walls or laid in trenches complete all as specified and directed
S&F Cast iron cowls 75mm complete all as specified.
Dismantling asbestos cement (corrugated, semicorrugated etc) sheets in roof coverings complete all as specified and directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ 150) as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ 150) as in roof covering/cladding to wall, ridge etc fixed with self tapping screws as specified
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for joint free coloured/designed tiles, area of each tiles exc 0.18 Sqm but n. exc 0.38 Sqm (600x600mm) in floors over and including 15mm thick screed bed of cement mortar 1:6 complete all as specified and directed
M&L for joint free coloured ceramic tiles, area of each tiles exc 0.18 Sqm but n. exc 0.38 Sqm as in vertical surface such as dado/ skirting over and including 10mm thick rendering in CM 1:4 to recieve tiles complete all as specified and directed
M&L for coloured Glazed ceramic wall tiles of size 300x450x 7mm to 8mm thick set and jointed in neat cement slurry and pointed with white or coloured cement over and including 10mm thick rendering or bedding layer of cement mortar 1:4 complete all as specified and directed
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc.led in any mortar all as specified and directed.
M&L for Machine cut Kota stone slab flooring 16-20 mm thick, laid over & including screed bed of 20 mm thick in cement mortar (1:4) and jointed with grey cement slurry mixed with matching shade pigment including rubbing and polishing complete, all as specified.
M&L for Kota stone slab 16-20 mm thick on vertical surfaces like riser of steps, skirting, dado and pillar laid over & including 10 mm thick in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L for RCC 1:2:4 type B1 (using 20mm graded stone agg) as in slab and shelves supported on walls complete all as specified and directed
M&L pre-polished Baroda green marble 14 -16 mm thick (table rubbed and polished) in step, jambs, pillars , window cills, cooking plateforms and the like in CM 1:4 incl pointing in white cement 1:2 using marble dust with admixture of pigment to match with marble including half round moulding and making hole for gas pipe over 15mm thick screed bed in CM 1:6 complete all as specified and directed
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed
Supply & fixing false ceiling at all heights with GRG (Glass Fibre With Semi With fully Reinforced Gypsum) false ceiling tiles of perforated 12mm Size 595 x 595 mm of approved texture, 12mm thick thick micro tegular design and patterns having moisture micro tegular edged or 1 0 mm content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws complete all as specified and directed
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed
M&L for half brick work with subclass ‘B’ bricks, straight or curved on plan to any radius built in CM 1:4 complete all as specified and directed
M&L for brick work except bricks with sub class 'B' old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed
M&L for 75mm thick PCC 1:3:6 type C1 (Using 20mm graded stone aggregate) as in plinth protection/path laid in panels, finish the top surfaces even and smooth complete all as specified and directed
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M&L for 15mm thick plaster in CM 1:6 on fair face of brick walls finished even and smooth without using extra cement complete all as specified
M&L for preparation of newly plastered surface of wall and applying two coats of internal acrylic distemper including a coat of primer of approved tint over a coat of wall care putty complete all as specified and directed
M&L for applying two coat of internal acrylic distemper of approved tint over a coat of wall care putty on walls after complete removal of existing treatment and preparation of old plastered surface by rubbing down, washing complete all as specified and directed
M&L for applying two coats of acrylic exterior emulsion paint (Apex) over a coat of primer incl over a coat of wall care putty after preparation of newly plastered/concrete surfaces on wall complete all as specified
M&L for applying two coats of weather proof exterior emulsion paint (Apex) after complete removal of existing treatment including preparation of old plastered/concrete surfaces over a coat of wall care putty on wall complete all as specified
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size exc 1.5 Sqm and n.exc 4 Sqm complete all as specified and directed
Taking down chowkhats or frames area n. exc 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed
M& L Solid (125mm X 63 mm Double rebate) factory made 100% solid WPC brown door frame made from 100% LEAD FREE (single extruded process) material with density 780 Kg / Cum & manufactured by an ISO:9001-2005 certified company, all as per specification drawings as directed by the Engr-in-Charge. the door frame should be water proof, termite proof, fire retardant and having excellent screw holding capacity complete all as specified and directed.
S&f factory made single extruded WPC (wood polymer Composite) solid both side prelaminated decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K valve 58-60 (Suspension Grade ) , calcium carbonate and natural fibers (wood powder/rice husk, wheat husk ) and non toxic additives (maximum toxicity index of 12 of 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with SS butt hinges of required size with necessary full body threaded star headed counter sunk SS screws all as per direction of Engineer-in-Charge.
S&F 35 mm thick factory made wire mesh solid WPC Prelaminated both side door shutter consisting of Density 650 kg/cum manufactured by an ISO 9001-2015 certified company . Door to be panelled with SS mosquito Mesh and XTN aluminium mesh for additional strength and safety purpose (confirming as per S:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 Nos MS powder coated butt hinges size 100x 25x2mm and 32 mm long steel screw drilled suitable to pass through both the walls of the MS tube. Other hardware should be fixed with 19x 6 mm size steel screws etc as per manufacturer's specification complete all as specified and directed.
S&F stainless steel wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specifed and directed
M&L for applying two coats of synthetic enamel paint to old undecorated wooden surfaces over a coat of pink primer including preparation, over 10cm width or girth complete all as specified
S&F windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM) and Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52x 25mm. Outer frame & mullion sections to have rebate for glazed shutters. Fly mesh with 20 mm GI flat beading for provision of guard bars/ grills. Fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap., handles 2nos of heavy duty stainless steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter with 0.36mm dia of wire and 1.40mm aperture. Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 12mm square guard bars with 110mm spacing c/c (Horizontal bay) to be welded on FI 20x6mm around except runner portion complete all as specified and directed.
S&F in repair double layer (ISI marked) rotational moulded PVC water storage tank cylinderical, vertical with closed top hoisted and fixed in position tank capacity 1000 Ltr with and including PTMT float valve 20mm dia and making connection for inlet and outlet complete all as specified and directed
S&F 250mm stainless steel sliding door bolts, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate
S&F 100mm size stainless steel butt hinges medium weight ISI marked, cold rolled
S&F 200mm long stainless steel barrel tower bolts all as specified
S&F 150mm size stainless steel handles all as specified
S & F in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes (6 Kg / Sqcm pressure rating) (single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) Soil, waste and vent pipes , single socketed in any length with rubber ring joints laid in trenches or in floorscomplete all as specified and directed.
S & F in repair 75 mm dia PVC (SWR) floor trap, with grating including jointing with solvent cement including fixing waste pipe etc complete all as specified and directed
S & F in repair 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) bend of any radius complete all as specified and directed.
S & F in repair PVC waste pipe 32 / 40 mm dia and length of pipe 750 mm medium grade with coupling complete all as specified and directed
S&F in repair vitreous china white wash hand basin flat back of size 550x400mm including CI/MS brackets including cutting for and pinning in brackets but including waste pipe complete all as specified
S&F in repair 15mm dia brass chromium plated Bib tap fancy type with wall flange complete all as specified.
S&F in repair 15mm dia brass chromium plated pillar tap with fly nut with long swan neck screwed for 15mm bore dia of pipe complete all as specified.
S&F in repair 15mm Stop valve angle cock fancy type, chromium plated with long shunk and cup (concealed type) high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified
S&F in repair PVC connection 15mm bore dia 450mm long with 2 Nos PTMT nuts with washer complete all as specified
S&F in repair 20 mm dia brass CP tubular towel rail D type 600mm long
Taking up or down 15mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed
S&F 15 mm bore dia of medium grade galvanised steel tubing with all fittings including tank nipple and fixed complete to wall or laid in floor including cutting through walls, floors, etc and their making good with existing surface complete in all respect as specified
S&F 15mm bore gun matel globe or gate valve with iron wheel, screwed both ends for iron pipes complete all as specified
Taking up or down 20mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed
S&F 20 mm bore dia of medium grade galvanised steel tubing with all fittings including tank nipple and fixed complete to wall or laid in floor including cutting through walls, floors, etc and their making good with existing surface complete in all respect as specified
S&F 20mm bore gun matel globe or gate valve with iron wheel, screwed both ends for iron pipes complete all as specified
S&F in repair of 20mm dia SS drapery rod, fancy type, SS knobs and brackets, fixed in any length complete all as specified and directed
M&L for 75mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in path finish the top surfaces even and rough to receive top layer complete all as specified and directed
M&L for rubber moulded coloured glossy finish cement concrete chequered tiles of size 30cm X 30cm X 20mm thick jointed in neat cement slurry and pointed in white or coloured cement and pigment to match the surface of tile as in floor over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed
M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manhole complete all as specified and directed
M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends etc complete all as specified and directed
Excavation in post hole (or similar holes) each n. exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface in any type of soil
M&L for cement concrete 1:3:6 type C1 (Using 20mm graded stone agrregate) as in foundation of posts, railing and similar work complete all as specified and directed by Engr-in-Charge
Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie.
S&F compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc built up from tow or more beam or channel sections or angles with plates including all lattice bars, stiffeners, gusset plates conforming to Fe410-W (Gde-E-250) quality-A
M&L for preparing new steel and iron surfaces of any description over 10 cm width /girth and applying two coats of synthetic enamel paint of any tint over one coat of red oxide primer complete all as directed
S&F in repair 18 mm thick with min density 600 Kg/Cum LEAD FREE PVC Celuka ply of both side plain white colour fixed with screws, solvent cement/ adhesive to make kitchen/bed rooms cabinet sides top and bottom and shelves inside the cabinets complete as per manufacturer’s specifications complete all as specified and directed
S&F 150mm Hasp and staple stainless steel, including bolt to hinge plate and fixed with screws all as specified and as directed
S&F auto closing hinges 35mm of 0 crank ( KH-001) or 8 crank (KH-002) openable at 110 degree for cupboard/kitchen cabinet shutters complete in all respect and fixed in position all as specified
Disconnecting the electrification and taking down DBs (any type of SPN DBs) and making good to the disturbed surfaces to match the existing surface all as specified and as directed by EIC. Note - Temporary power supply shall be provided by contractor.
Taking down U/S submain wiring aluminium etc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface.
M&L for sub-main wiring (concealed) with two single core 6 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of massinory including 25 mm dia non-metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by EIC.
Taking down carefully aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pedants, regulators, sockets, light fitting etc.. and making good the disturbed surfaces of walls/ floor etc matching with the existing surface all as specified and as directed by EIC.
Material & Labour for following type Point Wiring controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including casing caping on surface of wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates).
One light point controlled by one switch.
One ceiling fan point controlled by one switch.
One 3 pin socket outlet 5 Amps on the same board.
One 3 pin socket out let 5 Amps on the independent board.
All as per Item No. 106 above but 2.5 Sq mm multi stranded copper conductor with 2.5 Sq mm copper earth continuity wire connected to earth duly complete for one 15A Socket on Independent board all as specified and as directed by EIC.
Supply and fixing surface & wall mounted LED batten 4 feet with 1x20 Watt indoor decorative luminaries with and including electronic driver and 1x20 watt LED Lamp, pre-wired including necessary electric connection with copper flexible PVC cable of 0.50 Sq mm 3 core not more than 1 mtr in length from ceiling rose/connector to light fitting,
S & F angle lamp holder, PVC Polycab type with back plate suitable for batten fittings complete including fixing of 9/10 watt LED bulb all as specified.
Supply and fixing step socket type modular fan regulator 120/280 V , 100Watt all as specified and as directed.
Supply and fixing modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50 Hz all as specified and directed by Engr- in-charge.
S & F Switch Modular single pole, one way 6 Amps, 1 module 240 Volts AC all as specified and directed by Engr- in-charge.
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts 50 hz all as specified and directed by Engr- in-charge.
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC all as specified and directed by Engr- in-charge.
M & L for ceiling rose, surface bakelite, 65 x 50 mm, three terminals all as specified and as directed.
S & F sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623 all as specified and as directed.
S & F MCBs SPN 32 amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge.
S & F MCB SP, 6 to 32 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge.
M & L for Earthing complete with galvanised steel pipe electrode, 600 x 600 x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to galvanised earthing lead of 4 mm dia of iron or steel wire all as shown in electrical plate No. 5 all as specified and as directed. Note :- the cost of excavation and earth work PCC pit and CI cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed included in the unit rate for earthing all as specified and as directed by EIC.
Taking down old unserviceable existing service/UG cable all as specified and as directed by EIC.
Material and labour for XLPE insulated,LT armoured electric cable with aluminium standed conductor 1100 volts grade,cross-sectional area 35 sqmm ,3.5 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands,nuts,bolts and washers etc and testing complete all as specified and directed.
M & L for brick sub class 'B' 250mm x 115mm x 0.75mm and laid in trenches as in protection of UG cable complete all as specified and directed.
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.
M & L for 50mm bore GI pipe (Light grade) laid under road or fixed with pole/wall of culvert as in protection of UG cable incl necessary MS clamp and complete all as specified and directed.
Supply, fabricated and and fixing of street light bracket made out of GI pipe 1.0 Mtr long, 32 mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer all as specified and as directed.
M & L for LED Bldg Security light Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
M & L for disconnecting electric supply, taking down fan, cealing cable ends, dismantling blades carefully after unscrewing nuts and bolts of ceiling fan any size from existing position and bringing to AGE E/M store yard for clelaning all dusts, oiling, greasing all as specified and as directed by EIC.
Supply and fixing ceiling fan complete with blades, down rod and accessories, 230 Volts, 1200mm sweep Min air delivery 210 CFM with service value 6.00, BEE Five star rated with Brushless Direct Current Motor (BLDC), supper energy efficient, including provision of cable flexible 3 core of suitable size wire from ceiling rose to ceiling fan without remote complete including writing MES Number as per MES pattern complete all as specified and directed.
M & L for 40mm bore GI pipe (med grade) laid or fixed with wall for hanging of ceiling fan of 1200 mm sweep including necessary PCC work and MS clamp suitable for fan complete all as specified and directed.
S & F vertical load line in sheet metal enclosures MCCB TPN DB's with double door for incorporating MCCB as incomer and MCBs SP/SPN as outgooing , IP-43 , TPN 4 way with 200 amps rated busbar, 440 volts, as per IS-8623 including taking out old UNSV DB and making good the disturbed surface of wall and match with the existing surface compelte all as specified and as directed. ( Note- MCCB 3 pole 63 amps as main incomer will be included in quoted rate)
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
G S CONSTRUCTIONS (BID ID -3255431)
IRFANAHMAD CONTRACTOR (BID ID -3250309)
RADHA ENTERPRISES (BID ID -3248730)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .