| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 CrAccepted-AOC N A | PALWAL | HARYANA | 121004 | ₹9.3 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹9.5 CrRejected-Finance 32 9 EC ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | ₹9.5 Cr | L2 | Rejected-Finance Highest rate quated by bidderLowest rate quated by bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Technically Qualified |
| 4 | SATNAM SINGH AND CO Rejected-Technical | - | - | Rejected-Technical Non Technically Qualified |
Tender Value
₹11.1 Cr
EMD Value
₹22.2 L
Closing Date
1 Nov 2019, 5:00 pmClosed
General Manager (Garhwal)
Office of the Chief General Manger Construction Wing UKPJN Dehradun
Construction of Modern Doon Library under Dehradun Smart City Limited at Parade Ground Dehradun
2019_MDPEY_20604_1
3081/Nivida(Garhwal)/125 Dated 01/10/2019
Open Tender
Civil Works
420 days
Parade Ground Dehradun
Please refer t ender documents
3 documents required · 3 mandatory
₹11,800
PM Temp.Construction Unit(Khel) UKPJN Dehradun
₹22.2 L
Dehradun
4 Aug 2023
9 Oct 2019
4 Nov 2019
9 Oct 2019
1 Nov 2019
14 Oct 2019
14 Oct 2019
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removalof form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Edges of slabs and breaks in floors and walls
Under 20 cm wide
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineerin- Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
12 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand)
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :
Red sand stone - Exposed face machine cut and table rubbed with rough backing.30 mm thick
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of atching shade complete
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc, complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Kiln seasoned and chemically treated hollock wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634- 1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 8mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporatingprinciples of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide awater tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- inCharge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin-Charge.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Granite work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade etc. all complete.
Providing and erecting in position full height fully glazed partiton in 12mm thk. toughened glass fixed on Patch fittings including top patch fitting, bottom patch fitting, patch lock, floor spring of approved make for the door and S.S handle 600mm long, 30mm dia for the door including frosted film of llumar or equivalent make(If required) , shade & design on the glass. All damages to the floor work to be reinstated without any extra cost including the cost of other fittings & fixtures & hardware such as spider panels, glass to glass contactors etc complete, necessary holes, joints to be sealed with silicone sealant on all sides complete in all respects etc as per directions of Architect. The rate shall be inclusive of bent curved glass panels wherever the partition is curved in profile as shown in the layout plan.
Providing and fixing acoustic wall panel in combination of wood Based panels with lineal perforations and Fiber Glass Acoustical Wall Panel (in size 7 feet highx 450mm wide) manufactured from high density biosoluble resin bonded glass wool absorb or with a series of textile fabric, plain glass tissue backer and fabric wrapped edges. The wooden slats panels shall be non FR grade with melamine laminate panels 2440mm x 128mm x16mm with 2mm slats at 15 mm pitch, Toungue and Groove edges for seamless mounting. The back of the panels fixed wtih acoustical fleece for Sound Absorption. Panel is to be fixed on framework with screw fixed horizontal or vertical to wall at every 600mm with centre & edge bracket in tongue & groove system on framework. The cavity of framework should be inserted with rock wool with 48 kg and 50mm density and alongwith all accessories and direction of Engineer in charge Make- DEXUNE/ARMSTRONG
Providing and fixing poweder coated (minimum thickness of powder coating 50 micron) aluminium work for doors, windows and ventilators with extruded built up standard tubular sections of approved make, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.
Supply & Installation of GRC Screen (35-50 mm) in approved designs & sizes & thickness manufactured containing Alkali resistant Glass Fiber of appropriate sizes with dry cladding method using Fasteners, threaded rods, SS cleats etc.
Providing and laying cement concrete of 1:5:10 (40mm broken bricks aggregate) for sunken filling etc. all complete under instruction of engineer-in-charge.
Providing and Fixing Modular Toilet Partition with the following Specification Model Type : Top Hung Series Thickness of Compact Laminate :12 mm Thick Size of Cubicle : 1550mm x 1050mm or as in drawing Door Size : 800mm a) SS Top Rail b) Hinges – Gravity to close c) Privacy Thumb turn c/w Occupancy Indicator d) Coat Hook e) Door Knob f) Adjustable leg i) Rubber Door Stopper Lining j) Screws & Wall Plug
Supply and fixing of clay ridge roof Terra-Cota tiles size 8"x4" dimension should be perfect and free from crack etc. all complete under instruction of Engineer-in-charge.
Providing and applying of 3M make Frosted film on toughened glass as shown in the the architectural drawing etc. all complete under instruction of Engineer-in-charge.
Providing and fixing 8 mm thick laminated wood flooring including skirting (Grade - AC 4) of approved make and colour using planks of size 1200 x 200 mm ( approx.) laid in approved design / pattern as per drawing . The rate shall include the cost of under layer (2mm thick expanded polythene foam and 100 micron thick polythene sheet) , skirit clips , profiles , inner / outer corner and End piece or other necessary accessories as per manufacturer's specifications complete.
Providing and fixing of EPDM flooring of 10mm thick of approved design pattern all complete under instruction of engineer-in-charge.
Providing and fixing of 12mm thick toughened glass door of approved size with all ss accessaries with smart card access lock system of approved make and must be CE certified testing & Commissioning etc. all complete.
Uprooting rank vegetation and weeds by digging the area to a depth of 60cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.
Supplying and stacking of good earth at site including royalty and carriage for all leads. (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
Rough dressing the trenched ground including breaking clods.
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :
Holes 60 cm dia, and 60 cm deep
Holes 45 cm dia, and 45 cm deep
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)
Shrubs Plant
Hedge Plant
Preparation of planting beds for ground covers by excavating to a depth of 0.30m, removing all foreign bodies over 50 mm dia refilling with the mix of earth and manure in the ratio 3:1 flooding with water, filling with earth if necessary, watering, dressing, leveling and finally planting the specified ground covers. Stacking and disposal of material declared unserviceable and surplus including all leads and lifts (Cost of manure and extra earth to be paid separately) all inclusive of the mandatory maintenance of 12 months.
Supplying and stacking of Insecticides, Pesticides and Weedicides at site including royalty and carriage. DURSBAN or equivalent 1 to 2lts/200lts of water and sprayed. As follows.
Supply and stacking of Plumeria alba dwarf plant dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge
Providing and Displaying Ficus Starlight plant with fresh, healthy and attractive foliage 45 to 60 cm spread 75 to 90 cm ht., specimen bushy plant,in 35 cm Cement Pot as per direction of the officer-in-charge.
Supply and stacking of plant Tecoma stans of height 90-105 cm. bushy in big size HDPE bag as per direction of the officer-in-charge
Supply and stacking of plant Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and Displaying of Duranta Golden plant, having ht.15 to 20 cm bushty shape plant with fresh and healthy leaves in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge
Providing and Displaying of Wadelia trilobata plant,full of leaves in 15 cm size of Poly bags & as per direction of the officer-in-charge
Variable Refrigerant Volume / Flow Air-conditioning System. Outdoor Unit Supply, Instalaltion, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll compressors with all inverter compressor(s), special heat exchanger, ODU dB level less than 50 at a distance 1 Meter, centrifugal fan for condenser, ODU having front suction & top discharge, Y-branch as required, outdoor unit support, auto check function for connection error, auto address setting and capacity as mentioned below. VRF System shall be suitable for working on 48 °C ambient temperature, Refrigerant R 410A. Unit price shall be inclusive of full charge of Refrigerant Gas & Oil, Freight, Insurance, all Taxes & Duties etc. as applicable In INR. The COP of ODU mentioned below shall be at 100% load, 35 °C ambient temperature & at 27 °C DB inside temperature. All interconnecting piping, joints and U bends within the condensing unit shall be painted with two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution.
28 HP Cool / Heat Pump Unit (Minimum COP 4.0 - Cooling & Heating Mode, Single Circuit, Additional Refrigerant As Required For The System)
34 HP Cool / Heat Pump Unit (Minimum COP 4.0 - Cooling & Heating Mode, Single Circuit, Additional Refrigerant As Required For The System)
36 HP Cool / Heat Pump Unit (Minimum COP 4.0 - Cooling & Heating Mode, Single Circuit, Additional Refrigerant As Required For The System)
Indoor Units (Ceiling Mounted Low / Medium / High Static Ductable / FCU / Outdoor Air Processing Unit (TFA) & Cassette Units). Supply, Instalaltion, testing and commissioning of Indoor units equipped with pre-filter, fan section with suitable static fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities as per specifications and drawings. Ceiling Mounted Cassette Units
Ceiling Mounted Cassette Type : 1.6 TR - 777 CFM- Four Way
Ceiling Mounted Cassette Type : 2.0 TR- 830 CFM - Four Way
Ceiling Mounted Cassette Type : 2.6 TR - 1165 CFM - Round Flow
Ceiling Mounted Cassette Type : 3.2 TR-1218 CFM - Four Way
Ceiling Mounted Cassette Type : 4.0 TR-1253 CFM - Round Flow
Indoor Units (Ceiling Mounted Low / Medium / High Static Ductable / FCU / Outdoor Air Processing Unit (TFA) & Cassette Units). Supply, Instalaltion, testing and commissioning of Indoor units equipped with pre-filter, fan section with suitable static fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities as per specifications and drawings. Ceiling Mounted Duct Type
5.5 TR (2047 CFM) Ductable Type VRV Indoor Unit
8.0 TR (2542 CFM) Ductable Type VRV Indoor Unit
VRV High-Wall Unit
1.3 TR (424 CFM) Wall-Mounted Type VRV Indoor Unit
2.0 TR (671 CFM) Wall-Mounted Type VRV Indoor Unit
Supply, Instalaltion, testing and commissioning of Y-joints Including all Taxes & Duties, Freight, Insurance etc. In INR.
Corded Self Diagnostic Type Remote Controllers. Supply, Installation, Testing & Commissioning of Corded Self Diagnostic Type Remote Controllers Including all Taxes & Duties, Freight, Insurance etc. In INR.
Main Intelligent Central Controller System. Supply, Installation, Testing & Commissioning of Main Intelligent Central Controller - I Touch System Suitable For 64 Indoor Units To Operate, Monitor, On / Off, Temperature Setting etc. Including all Taxes & Duties, Freight, Insurance etc. In INR.
Plastic Propeller Fans. Supply, installation, testing and commissioning of propeller exhaust fans of various capacities as given below suitable for 240 volts, 50 Hz, single phase AC supply complete with gravity louvers & speed regulator etc.
Refrigerant Piping for VRV / VRF System. Supply, installation, testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R 410A duly insulated with elastomeric nitrile rubber type tubular insulation of density 55+/-10% Kg/m3 between indoor & outdoor units as per specifications. External refrigerant piping shall be laid on 16 G GI covered perforated cable trays. Piping inside occupied area & vertical shaft inside the AHU Room shall be supported using 16 G GI hangers. All exposed pipe shall have UV coating on insulation & cost to be included in the piping. Cable tray is quantified seperately.
41.3 mm O.D. (Min. Wall Thickness - 1.43 mm, insulation - 32 mm thick)
34.9 mm O.D. (Min. Wall Thickness - 1.21 mm, insulation - 32 mm thick)
28.6 mm O.D. (Min. Wall Thickness - 0.99 mm, insulation - 32 mm thick)
22.2 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 25 mm thick)
19.1 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 25 mm thick)
15.9 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 25 mm thick)
12.7 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 25 mm thick)
9.5 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 19 mm thick)
6.4 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 19 mm thick)
Condensate Drain Piping. Supply, installation, testing and commissioning of UPVC condensate drain water piping of density 20 Kg/m³ complete with fittings like elbows, tees, reducers, bends, flanges, supports, insulation etc. as required and of following sizes.
25 mm dia pipe, Insulation Thickness - 9 mm
32 mm dia pipe, Insulation Thickness - 9 mm
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required..
Supplying and fixing of external thermal insulation on ducts with Cross Linked Closed Cell Polyethylene FR-XPE, density 33±3kg/cum, Class O fire rating insulation, tape & adhesive (pidilite SR -998) as required of following thickness. 13 mm thick Aluminium Metalized Insulation
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. (DSR 2018 E&M 16.13)
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. (DSR 2018 E&M 16.17)
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. (DSR 2018 E&M 16.13)
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. (DSR 2018 E&M 16.13)
Supply, installtion and testing of MS Louvers constructed with casing in 14 G & louvers in 18 G construction for supply / exahust air application for ventilation fan including bird screen, fixing members, rain protector, free area of 55% etc as required to suit the site conditions.
Supply, installation and testing of multiblade box type Galvanized Sheet Steel construction damper for ducts to be provided with suitable links and quadrants for control of volume of air.
Supplying and fixing of thermal insulation on exposed roof (underdeck) with 13mm thick Cross Linked Closed Cell Polyethylene FR-XPE insulation of density 33 Kg/m³ with adhesive (pidilite SR -998) etc. as required & finally fixed with the help of rawl plug & dash fasteners in ceiling.
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender.A) Power cabling (XLPE insulated Aluminium / Copper conductor as given below armoured / unarmoured cables of 1.1 KV Grade) including cable end termination with brass compression glands & lugs etc as per specification.4C x 16 Sq. mm Copper Conductor (Unarmoured) For VRF Unit
For VRV Indoor Units (Cable shall be laid running in the PVC conduit through wall & ceiling along with the approved route. AC Contractor shall include the cost of chiselling & finishing the wall / ceiling. Cable from ODU electrical feeder panel shall run along with refrigerant piping on common cable tray)
3C x 4 Sq. mm Copper Conductor (PVC insulated, PVC sheathed flexible wire)
3C x 2.5 Sq. mm Copper Conductor (PVC insulated, PVC sheathed flexible wire)
Transmission & Control Wiring. Providing & fixing of control cum trans-mission wiring of copper between indoor and outdoor unit in 20 mm PVC Conduit. AC Contractor shall include the cost of chiselling & finishing the wall / ceiling . 2C x 1.5 Sq mm (PVC insulated, PVC sheathed flexible wire)
Earthing & Rubber Mat. Supply & laying of 4 mm dia. GI wire or in recess for loop earthing as required.
Supply and installation of GI perforated cable tray with required GI bend, reducer, cross, tee etc. including GI threaded hanger / channel support of following sizes.
150 mm x 50 mm x 1.6 mm
300 mm x 50 mm x 1.6 mm
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of ittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P.brass pillar tap
Providing & fixing low-flow C.P. hand spray with lever control (health faucet) Tested up to 6 bar flow pressure, continuous flow mode and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects as per direction of Engineer-Incharge.
Providing and fixing brass bib cock of approved quality :15 MM Nominal Bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15 MM Nominal Bore
Providing and fixing PTMT grating of approved quality and colour.125 mm nominal dia with 25 mm waste hole
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410 x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. ( Internal work - Exposed on wall )
25mm dia
32mm dia
50mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15mm dia
20mm dia
25mm dia
32mm dia
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.. (For External Work).32mm dia
Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finish with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 10 kg/cm2 etc. complete in all respect.
25 mm dia. Nominal bore
32 mm dia. Nominal bore
50 mm dia. Nominal bore
Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). 20 mm nominal bore
Making connection from existing Municipal water line i.e drilling/cutting, fixing ferrule and making connection with the service pipe, complete including excavation, refilling, disposal of surplus earth, and supplying all material so to make it functional and also taking approval from the concerned authorities. If it is necessary to break or excavate the road for laying pipes and making connection, it should be restored to its original surfacing.
Providing , fixing testing and commissioning of SWR TYPE -B soil, waste and vent pipes (IS:13592-1992) including all fittings confirming to IS 14735-99,rubber ring confirms to IS 5382 including all required fittings e.g. bends, junctions, cowls, offsets, access pieces,clamps etc. jointing with ring Joints as per recommendation of manufacturer specifications including cutting, chasing of brick/RCC structure and making good the same as required complete in all respects as per direction of Project -In- Charge.
110 mm outer dia
160 mm outer dia
Providing , fixing,testing and commissioning of uPVC 6kg/cm2 pipe to IS:4985:2000 complete with fittings, clamps and hinges including cutting and making good the walls and ceiling for waste pipes, bath wastes, overflow, kitchen equipment waste connections and condensate drainage including cutting of brick/RCC wall as required and making good the same as directed by the Engineer-in-charge.
40 mm outer dia
63 mm outer dia
Providing and fixing uPVC rain water pipes of 6 Kg/Cm2 including bends, junctions, cowels, offsets clamp, etc. complete including jointing with cement solvent including cutting of brick/RCC wall wherever required and making good the same as directed by the Project-In-Charge. 110mm outer Dia
Providing & fixing UPVC deep seal P or S trap of self cleansing design with or without vent arm with provision for connecting pvc inlet fitting complete including cost of cutting and making good the walls and floors wherever required.110mm inlet Outer Dia and110mm outlet outer Dia
Providing and fixing UPVC Floor Drain consisting of 110x63mm Reducing elbow (with UPVC grating and pipe to be paid separately), complete as per instructions.
Providing and fixing UPVC Clean Out plug (FCO & COP) with end cap for opening, complete in all respects. 150mm dia
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
200 mm dia. R.C.C. pipe
Constructing brick masonry catch basin with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 coarse sand), 200m thick foundation concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40mm nominal size) inside and outside plaster in cement mortar 1:3 (1 cement: 3 coarse sand). inside finished with floating coat of neat cement, making haunches and channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) neatly finished, complete as per standard design including excavation, refilling and disposal of surplus earth.'Size 450x450x450mm inside with precast S.F.R.C. grating of approved design and sample fixed in RCC slab in cement 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete as per site conditions.
Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand), RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size), 20mm thick foundation concrete 1:4:8 mix (1 cement : 4 coarse sand; 8 graded stone aggregate 40mm nominal size), inside and outside plastering 12mm thick with cement mortar 1:3 (1 cement:3 coarse sand), finished with a floating coat of neat cement inside and rough plaster on outside and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size), neatly finished complete as per standard design including excavation, refilling and disposal of surplus earth. Inside size 60x60cms and 60cms deep including SFRC cover and frame (medium duty MD-10 grade) 455x610mm internal dimensions including centering and shuttering complete.
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:150 x 100 mm size P type
Constructing Brick Masonry circular type manhole 0.90 m internal dia at bottom and 0.56m dia at top with in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 0.90m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including Excavation, centering, shuttering all complete.( foot rests shall be paid separately). with FPS bricks class designation 75
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter
Providing and fixing M.S structural work fabricated from standard sections e.g. M.S. rounds, angles, channels, plates including cutting to size, welding, drilling with concrete drilling bits and fixing dash fasteners in RCC structural members as directed by Engineer-in-charge including cutting and making good the walls, ceilings and floors (for all types of pipe supports, clamps, etc. unless included in relevant pipe items) complete, as directed by the Engineer in charge.
Construction of Rainy well of size 4.0 metre dia and 4.0 metre effective depth including all civil works with neccesary excavation, brickwalls, plain cement concrete foundation and reinforced cement concrete beams and top slab, refilling and disposal of the excavated soil and doing 250mm dia boring upto minimum 45m depth. and fixing 150mm dia slotted UPVC pipes including laying off necessary loose boulders/ ballast complete in all respects. (Shop drawing to be got approved before execution)
Construction of brick masonry desilting chamber of size 200x100x60cm (effective depth) before rainy well with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) , foundation concrete 1:4:8 mix (1 cement : 4 coarse sand; 8 graded stone aggregate 40mm nominal size), inside and outside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement inside and rough plaster on outside, including fixing of grating , neatly finished complete in all respects including neccessary excavation, refilling and disposal of surplus earth, complete. (Shop drawing to be got approved).
Providing and fixing pumping set (Complete manufactured Skid-Mounted arrangement with manifold and accessories) with stainless steel SS-304 stage casing and SS-304 impellers with stainless steel shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 180- 230 Volts, Single phase, 50 Hz A.C. supply with pressure gauge and with gunmetal isolation cocks, vibration elimination pads etc. complete with base and frame, nuts and bolts and necessary RCC foundations as per requirement as per instructions and pump shall have following duty: No. of pumps : 2 (1 Working + 1 Standby), Head : 40M, RPM: 2900, Capacity approx 150 LPM, Location: in Plumbing Plant Room,
Providing and fixing compact monoblock dry motor submersible pumps of suitable rating, with non-clog free flow open impeller, suitable for operation on 415 volts +10% , 3 Phase, 50Hz, A.C supply, speed 2900 RPM including oil chamber, guide wire for lifting & lowering of pump, M.S. galvanized lifting chain, duck foot bend complete. The pump sets shall be supplied with required accessories & as per specification with the following : Complete inlet, outlet and header piping of suitable dia (velocity shall not exceed 1.5m/s) -- 1 Lot, Butterfly valve and Dual Plate NRV of appropriate dia and rating - 1 Lot, Necessary cables from pump sets to pump starter panel - 1 Lot, Electrical control panel having all necessary accessories & safety devices of standard specifications and suitable for receiving incomer cable to connect complete. (Panels with sump pumps near each sump as per site conditions). -- 1 No., Discharge :15 m3/Hr, Head : 12 m, Solid Handling : 40 mm. Note :Pumps shall be operated on cyclic timing, The entire system along with pumps & control panel must be sourced from single manufacturer only for unit responsibility, One set consist of 2 nos.of pumps - 1 working & 1 stand by (Complete set as above with 2 nos. pumps including cost for valves, piping, Control Panel and Cabling, Level Controllers, pressure gauges etc as required and as specified)
Terrace Pump:(Multi stage)Providing and fixing multi stage horizontal centrifugal pump with volute brozne impeller conntected to TEFC induction motor suitable for 400/410 Volts, 3 Phase, 50 Cycles , AC supply with the following specifications: a. Capacity : (1 Nos. 900 lpm), b. Head : 35 m.c. HP : 10 HP approx. or As required, d. RPM : 2900, e. Mover : Electric Motor driven, f. Material of Construction: Shaft & Sleeve : S.S. 410, Impeller : Bronze, Bearing : Grease lubricated Seal : Mechanical Seal(Make-Flow guard, Leak proof,Burgman)
Air Vessel for Fire Pump:Fixing of air vessel of the following.specifications a. Diameter : 200 mm,b. Shell Thickness: 8 mm, c. Dish Ends : 10 mm, d. Height : 1000 mm, e. Finishing: Two coats of red enamal paint over primer out side and two coats of epoxy coating inside.f. Material of construction: M.S, g. Test Pressure: 26 Kg/Sq.Cm, i. Height of supporting legs: 400 mm, j. Quantity
Providing and fixing arch vibration elimination pads for pumps ,including bolting to foundations. Type 'A' (For Terrace Pumps)
Providing and fixing dual type pressure switch suitable for 1-20 Kg/cm2 including electrical connections setting of Cut-In and cut-Off pressure complete in all respects.
Providing, laying, jointing, testing and commissioning of following sizes of MS 'C' Class (Heavy duty) pipes conforming to IS-1239 with all accessories like orifice plate(of required dia), all fittings (standard MS fitting with welded joint shall be used on the pipes) including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer,two coats of synthetic enamel pain including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fastners) as per specification. G.I. pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls/floors and sealing the sleeves with glass wool in between & fire sealent compound at either end all as per Project Manager’s / Consultants requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwire and then supply of the same shall also be included for rates under this head. Welding of any kind on the galvanized support / hanger shall not be permitted including synthetic enamel paint of approved shade over a coat of zinc primer. Supply & Fixing of below items (including all necessary/required accessories). 80 mm dia
Providing & Fixing of wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 36.5 Mtr. length x 20 mm dia high pressure hose reel tubing as per IS: 444 with gun metal (GM) shut off nozzle having 5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include 25 mm dia M.S. pipe connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall through anchor fasteners / cement concrete block as and when required. (For internal hydrant system).
Providing & fixing of IS marked (IS:15683) portable fire extinguisher, carbondioxide type flat base including valve, discharge hose of not less than 10 mm dia. 1 M long & complete in all respects including initial fill with CO2 gas confirming to IS:307-1966 filled to a filling ratio of not more than 0.667 of not more than 0.667 and wall suspension bracket - With every FHC, UPS Room. Capacity 4.5 kg
6 Kg. ABC Powder type fire extinguishers are manufactured and marked to Indian standard IS: 13849. Suitable first aid appliance for fighting fires in Class A, B & C fire that is wood, textile, flammable liquids & gases - With every FHC and one for 300 Sq.M area
Sand Bucket with Stand (6 Bucket)
Design, manufacture, assembly, wiring, testing at works and supply to site of following panels/distribution boards/switch boards. The boards shall be designed and fabricated as per general specifications, technical details, specifications and notes as part of this tender /BOQ and relevant BIS codes. FIRE PUMP PANEL: IP Rating: IP 54, Incomer :1 No. 63 A, 35 KA, 4P MCCB of motor duty - only Magnetic release. (Adjustable Magnetic release upto 125A MCCB OR Micro-Processor based release above 125A MCCB). MCCB shall have 1NO + 1NC auxiliary contacts + a trip contact, Incomer Metering & Indication:415V / √3 / 110V/ √3 PT's, Cast Resin type, 3 Phase for metering & indications, suitable rated 6A, TP MPCB of the fault withstand capacity as of the panel on the primary side of PT & suitable rated 6A, TP MCB on the secondary side of PT, R,Y,B phase indication lamps (110V) LED Type, ON' & Trip indication lamps (110V) LED Type, Cast resin metering CT's for each phase of class-1 accuracy & of suitable burden & ratio 1 No. Digital VAF + PF Meter (110V) (With RS 485 Port), Fire pump panel to be complete with all control wiring / terminals for linkage with flow switches / pressure sensor for auto operation of pumps and as per the requirement of Local Govt. Fire Officer, Fire Pump Panel as described above.
Supply, installation, testing & commissioning of following sizes of 1100 V grade PVC Aluminium armoured cables, PVC insulated PVC sheathed, including cable trays /supports as per site conditions. 3C X 10 Sq.mm
Supply and laying of 4C x 1.5 Sq.mm copper armoured cable including termination. (Control cable shall be paid separately under control cable head).
Supply and laying of 2C x 1.0 Sq.mm copper armoured cable including termination. (Control cable shall be paid separately under control cable head).
Supply & making end termination with brass double compression glands for the following PVC insulated, PVC sheathed & armoured 1100 V grade Aluminium cable including cost of crimping lugs/ferrules, compression glands, solder, cable sockets, insulation tape etc complete as required. 3C X 10 Sq.mm
Body earthing of the various equipments/ motors/ switchgears supplied by the bidder with suitable size of earthing strip/wire etc. as per IS:3043 and as required including provision for connection of earthing to main earthing pits. (G.I earth strip of size 25 mm x 6 mm).
Desktop, CPU along with monitor, keyboard, mouse, antivirus & OS.
Bio-Metric for Smart Library.
CCTV Camera (IP Based) along with accessories.
RFID Handheld Portable Reader
RFID Book Return Station
Smart Cards
Self Adhesive RFID Tags (for Book)
Self Adhesive RFID Tags (for DVD
Smart Card Printer with accessories
Smart Screen 75"
Laptop 15 inch
Wireless Presentation Solution
Intelligent Door System
RFID Tagging Job Work (for Book)
Firewall (UTM)
Structural Cabling with accessories
9U wall mount network rack with accessories
42 U wall mount network rack with accessories
Network Switch ( Manageable 16 Ports)
Network Switch (Manageable 24 Ports)
Servers (Data and Application)
Software’s
KVM Switch
Leased line connectivity (for 1 years)
E-Content (Textbook based Educational Software, E- Library etc.
Supply of XLPE Insulated power cable (conforming IS-7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor. ARMOURED 3½ CORE
300 Sq.mm(XLPE)
70 Sq.mm(XLPE)
50 Sq.mm(XLPE)
25 Sq.mm(XLPE)
ARMOURED 4 CORE 6 Sq.mm(XLPE)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.For LT Distribution
3½ X 240 sq. mm (45 mm)
3½ X 70 sq. mm (45 mm)
3½ X 50 sq. mm (35 mm)
3½ X 25 sq. mm (28 mm)
4 X 6 sq. mm
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
CABLES: Supply of following sizes of 1.1kV grade XLPE insulated, PVC type ST-2 inner & outer sheath, Aluminium conductor, Armoured cables as per IS:7098 Part-I. 6 sqmm 4 core
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sandcushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply & fixing of 4.5 mtr GI Octagonal Pole of approved make
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.5 meter and upto 6.5 meter
Supply and fixing of 8 Watt LED bollard light (1000 MM)
Supply and fixing of LED Street light Fitting made up of pressure die cast housing with toughned glass, diffuser with driver set suitable for 45 Watt. Confirming to IP 66 protection
Supply, Installation, Testing & Commissioning of Solar PV stand with Street 20W LED Lighting System comprising of one75 Wp SPV module, one 12 V,75 Ah Tubular Plate sealed maintenance free VRLA Gel Battery, one White LED luminary of 20W with in-built inverter, Charger, dusk to dawn circuit for automatic switching on & off at dusk to dawn, automatic dimming circuit (automatic/optional) based on real time clock for full bright operation during first six hours and half bright operation for rest hours, 5M pole, one charge-regulator, module mounting structure, Pole mounted Battery box, cables and other fittings along with 5 (five) years guarantee / warranty period (25 years for SPV Module).
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required.
Earthing with G.I. Earth plate 600mm X 600mm X 6mm thick including accessories and providing masonary encloser in cement mortor, cover plate having locking arrangment on the top and G.I. watering pipe 20mm dia 2.7 meter long etc. (but without charcoal or coke and salt ) complete as required.
Earthing with Copper Earth plate 600mm X 600mm X 3mm thick including accessories and providing masonary encloser in cement mortor, cover plate having locking arrangment on the top and G.I. watering pipe 20mm dia 2.7 meter long etc. (but without charcoal or coke and salt) complete as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)
Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For horizontal run)
Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
Earthing with G.I. Earth plate 600mm X 600mm X 6mm thick including accessories and providing masonary encloser in cement mortor, cover plate having locking arrangment on the top and G.I. watering pipe 20mm dia 2.7 meter long etc. (but without charcoal or coke and salt ) complete as required.
Lightning Arrestor described above. UPS for Emergency Lighting, & Security Systems etc. Supply of IGBT based with in-built galvanic isolation transformer, micro processor controlled True On line double conversion 3 phase input and 3 phase 415V output 7.5 KVA UPS (N) consisting of following: 1 No. UPS module with integrated 100% rectifier + inverter.Battery Circuit breaker for UPS module in CRCA housing with all required fixing accessories & hardware.Galvanic isolation transformer k-rated, at the inverter output of UPS Module. RS 485 BACnet / Modbus protocol with UPS module for BMS Connectivity. All the informations to be provided to the BMS vendor at one point. In-built static switch for bypass & inverter in UPS module.In-built Manual maintenance bypass. Interconnecting copper cabling (DC cabling) between UPS, Active filter, Battery breaker & Batteries of required length and size. OC Web card for web enabling with an inbuilt facility of event logging. Sealed maintenance free batteries for 7.5KVA UPS with 90mins. backup time on UPS module with inerconnectors, Rack and accessories. Rack shall have shrouds for safety from live battery terminals. Suitable MS stand of 450mm high for UPS module duly painted. RAM module with UPS and Cat 5 cable for RAM connectivity. Charger Capacity 120%. 7.5 KVA UPS described above.
DG SET 400 KVA . Design, supply, installation, testing & commissioning of DG Sets and its ancillaries : Supply ,Unloading & shifting, Installation, testing, commissioning and alignment of OF D.G. SETS. DG SET WITH RADIATOR - IN ACCOUSTIC HOOD . Design, Manufacture, Supply at site of Prime Duty continuous rated 4 stroke, 1No 380 kVA DG Set comprising of Engine of 1500 rpm, Radiator Cooled, coupled and aligned with continuous rated 380 kVA , 415 V ± 1%, 3 phase, 4 wire, 50 Hz. 1500 rpm, 0.8 PF industrial type brushless, AC Alternator with electronic AVR mounted on a common base frame. Alternator shall be complete with suitable terminal box with Aluminium link work to accomodate the Aluminium Armoured cables /Bus duct as may be required.DG Set shall be complete with following accessories: 3mm thick MS painted 205 litres Day Oil Tank with float & board level indicator Fully charged Lead Acid batteries with painted angle iron stand Battery leads Residential Silencer & Flexible coupling Anti vibration mountings as required. O/M Manuals, Test Certificates & Warranty certificates : DG Set shall have 1 set (Original) + 3 sets photocopies of engine & alternator O/M manuals, Test certificates of Engine & alternator, warranty certificates of engine, Alternator & Batteries etc. Fuel Pump & Governor : Engine fuel pump shall be with electrically operated actuator & electronic / digital governor. ) suitable for synchronization. Engine fuel pump shall be inline fuel pump & Mechanical governor. (For 600 KVA & below)
DG Set Controller:The DG Set shall be complete with DG Controller. The controller shall be able to perform the following functions & monitor various parameters:: Perform following functions: Manual Start / Stop facility through key / Push button & with remote input acceptance for remote start and with cranking relay. Engine monitoring & protection:Lub oil pressure Coolant temperature, Engine Speed, Run Hour, Battery Voltage, Low Lub oil pressure & warning, High coolant temp. warning & shut down, Low coolant level shut down, Over speed shut down, Charging failure indication,Low / high battery voltage warning, Fail to Crank / Fail to start / Shut down, Alternator (AC) metering & protection : 3 Phase Amps, 3 Phase voltage, KW, KVA, PF,HZ, Over voltage shut down, Under voltage shut down, Over frequency shut down, Under frequency shut down, Over current shut down, Field overload shutdown, Loss of sensing voltage shutdown, Inbuilt Stop button. 380 kVA DG Set with Radiator - In Accoustic hood as described above
Wiring for fan point/Light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required ( Primary Point).
Wiring for fan point/Light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required . Secondary point
Wiring for 6A point with 1.5 sq. mm FRLS. PVC insulated copper conductor single core cable in surface / recessed PVC conduit with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supply and wiring of power point with 2X4sq.mm+1X4 sq.mm FRLS PVC insulated copper conductor cable in PVC conduit with G.I. switch box, 16A modular switches with 6/16A 5 pin socket, modular cover plate, surface or deep tee with all accessories
Wiring for mcb control light point with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC and earthing the point with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required (Primary Point).
Wiring for mcb control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit with earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required (Secondary Point).
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete as required confirming to IS :374/1979 with upto date ammendments. Ceiling Fan (Energy Saver 50 W)-1200 mm Sweep
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supply & installation of the PIR outdoor switch sensor 270°, detection field 180 m², Maximum range 15 m - IP 55, Consumption 0.4 W on standby, All load 8.5 A - 240 V, PIR outdoor switch sensor 270°,vacancy & occupancy mode (push-button override or mobile configurator), automatic terminal connection.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. PVC . Conduit 25 mm
Supply, Installation testing and commissioning of telephone Tag block Krone connector with enclosure and lock complete as mentioned below :-20 pair
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module
Supply, Installation testing and commissioning RJ - 45 Computer Jack cat 6 with shutter Modular (1Module)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole and neutral
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole and neutral
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
Supply, Installation, Testing & Commissioning of ultra modern design soft ligt and glare free symmetrical illumination 24 Watt LED light suitable for Grid Ceiling,
Supply, Installation, Testing & Commissioning of 10 Watt LED wall light (10 watt LED Bulb) fixture .
Supply, Installation, Testing & Commissioning of Recess mounted 10Watt LED downlighter
Supplying, erecting and testing of approved make Exhaust Fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finished and as required.380mm sweep 900 RPM
Call bell/ buzzer, single phase
SPV Module and Structure: Poly Crystalline 325Wp Modules,With inbilt bypass diode,Frame should be Al anodize,power tolerance of +/- 3%,Vmp and Imp shall not vary more than 2%, With junction box arrangement having inbuild bypass diode,weather proof,IP-65,with RFID tag.Material warranty upto 5year and performance warranty 25 year. 70 kwp Enkay solar equivalent.
BALANCE OF SYSTEM (BOS): Roof mount fixed type structure with all required material for execution and all the civil work. (Make-Reputed) 1 Lot Bharat Solar or equivalent. SUITABLE FOR 70 KVA SOLAR SYSTEM GRID CONNECTED INVERTER,House MPPT,DG set interactive,output should compatible with grid requency. GBT/MOSFET,Microprodessor,DSP,415 V,3- Phase,50Hz +/-3%,Ambient tem -20 dec to +50Deg,Humidity 95%, Protection IP-20 for indoor and IP-65 outdoor,grid voltage tolerance -20% to +15%, No load losses lees then 1% of rated power,efficiency 93% or above, THD less then 3%,P.F more then 0.9,fully automatic,having internal protections against any fault in feeder,Built-in meter and data logger to monitor plant, inverter desing as per IEC/BIS standard for efficiency and enviornmental tests as per IEC 61683/IS 61683 and IEC 60068-2 (1,2,14,30).MPPT as per IEC.60068-2(1,2,14,30)/BIS.Junction box should be IP-65 for outdoor and IP 55 for indoor as per IEC 529.Inverter should be grid as well as DG integrated. 1 set Delta/ABB/ Solax or equivalent. DC Cable from String to SMB 4 sq mm COPPER WIRE UV PROTECHED DOUBLE INSULATED. 300.00 mtrs. Polycab/KEI or equivalent. DC cable termination with MC4 connector size 1cx6 sq mm,providing suitable size male female connector weathe rproof IP65. l lot Elmax. DCDB 5 in 5 out in wp Enclosure 1 Set ONEXIS/JMV or equivalent. Supply & Laying of 1Cx4 sqmm Copper insulated PVC Insulated wire 1.1 KV Rated (From SMB to Inverter 1 Runs per phase) 50.00 mtrs POLYCAB or Equivalent. SITC of Termiantion of DC Cable 1cx 4 sq mm with MC4. 16 Nos. Elmax.
Electrical/ AC Side: Supply & Laying of 1Cx16 sqmm XLPE 1.1 KV Rated Copper wire in flexible conduit (Inverter to LT panel , 2 Runs per phase). 100 mtrs. POLYCAB, Havells or equivalent. Ring Type/Pin Type Heavy Duty Tinned copper Lugs for 16 Sqmm, copper wire with M12 Hole & M12 Suitable Nut Bolt 35 mm with two plain washer & Metallic jel, high grade heat shrinkable sleeves on each cable termination [make: HEX/Any reputed make as per Client team Approval] LT CABLE @ TERMINATION Inverter and Panels. 1 Lot DOWELLS. Weather proof PG gland IP 65,for 1Cx16sq.mm Copper wire for Termination of AC wire/cable. 20 Nos. Hensel/COMET. ACDB with 4 Pole MCCB of 125 A rating 16 KA in IP 65 proof enclosure,metalic with mounting arrangement. 1 No. Encloser-Local manufactured, MCCB- ABB/ Schnierder/L&T, 4cx70 Sq mm copper. Arm. Cable/Wire on existing cable tray from Isolator to Electrical/DG Room . 50 mtrs POLYCAB, Havells or equivalent.Supply & installation of G I - 25x3 mm strip for component earthing like LDB, panel etc. 50.00 mtrs LOCAL, Supply and installation of Chemical Earth pit with 17.0 mm dia ,3.0 mtrs Length copper bonded rod with suitable size clamp, 3mm thickness pvc earth Pit chamber and identification marking numbers. 3 Nos. GPS. JMV or equivalent.Data logger. 1 Lot, I&C. 1 Lot. Total (supply + Installation) 70 kwp
Godrej Boltless Compactors (Mobile Shelving), 3Bay System ( 1300 width System ) 2411 height x 1300 w x300/400 depth mm No of loading levels per Body : 05 nos Load per level : 130 kg UDL Total 10 Nos bodies 03 SFF and 35 DFMD,3 SFMD Unit - Total 228 Nos bodies
Supply and installation of elevator of 15 person capacity with 3 stops, openings of speed 1m/s, car dimension, 1100x2200x2200 and Door opening 900 mm wide x 2100 mm high of approved brand as per instructions of Engineer-in-charge.
VKJ Projects Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid