Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED. | |
| 2 | L2₹10.6 L+₹14,341 (1.37%)Rejected-Finance | L2 | Rejected-Finance Higher Bid Value. | |
| 3 | L3₹10.7 L+₹23,829 (2.28%)Rejected-Finance | L3 | Rejected-Finance Higher Bid Value. | |
| 4 | L4₹10.8 L+₹35,270 (3.37%)Rejected-Finance MAHUT PARA GOSALA MORE P O DENGUAGHAR JALPAIGURI 735112 | JALPAIGURI | JALPAIGURI | WEST BENGAL | 735112 | L4 | Rejected-Finance Higher Bid Value. |
Tender Value
Refer Docs
EMD Value
₹20,947
Closing Date
26 Nov 2021, 2:00 pmClosed
Ex. Engineer, Jalpaiguri Electrical Division PWD.
Office of the Executive Engineer, PWD, Jalpaiguri Electrical Division, Purta Bhavan, Hakimpara, PO and District Jalpaiguri, PIN 753101.
Urgent Internal Electrical Installation Work for setting up of Hybrid CCU at Mal Sub Division Hospital, Jalpaiguri.
2021_WBPWD_350116_1
WBPWD/EE/JED/NIQ 22e/Q of 2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Hybrid CCU at Mal Sub Division Hospital.
Please refer Tender documents.
2 documents required · 2 mandatory
₹20,947
22 Dec 2021
10 Nov 2021
29 Nov 2021
10 Nov 2021
26 Nov 2021
10 Nov 2021
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed]
On board 5A
Average run: 10 Mtr.
Average run: 12 Mtr.
S&F 240 V, 4 nos. 20A plug socket with separate 4 nos. 20A Piano key type switch, indicator incl. S & F 300x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
S&F 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite top cover of 3mm thick and making necessary connections as required (Computer Board) [PWD/GS Page: E-7 Item: 26 ]
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
S&F 240 V one number five Pin 20A flush type plug socket with one number separate 20A Piano key type (Anchor make) switch on sheet metal switch board embedded in wall incl S & F 150x100x65 mm MS (16 SWG) switch board and bakelite top cover of 3mm thick and making necessary connections as required . [PWD/GS Page: E-6 Item No.: 22]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required [equivalet to PWD/GS Page: E-14 Item: E/1/a]
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [PWD/GS Page: F-5 Item: 9]
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm)
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm)
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm)
S&F double door 6Way Vertical TPN MCB Distribution board for 125A MCCB incomer with IP-42/43 protection, on angle iron frame on wall incl. Inter connection & provision for earthing attachment (Legrand /Siemense /Havells Metalica /ABB Elegance - as per direction of EIC) [PWD/GS Page: D-11 Item: 15]
S&F double door Horizontal 6-Way TPN MCB Distribution board with IP-42/43 protection, concealed in wall (Legrand: (607716 /Siemense /Havells Metalica /ABB Elegance - as per direction of EIC) [PWD/GS Page: D-10 Item: 14 ]
S&F double-door (2+12) Way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall. (Legrand: 607713 /Siemense /Havells Metalica /ABB Elegance - as per direction of EIC) [PWD/GS Page: D-09 Item:13]
S&F 415 V L&T 125A 4- Pole MCCB of Breaking capacity 35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection[PWD/GS Page: D-8 Item:10]
Supply & fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand /Siemense /Havells Metalica /ABB Elegance - as per direction of EIC) [PWD/GS Page: D-6 Item: 7]
63A FP MCB
63A TP MCB
16-32A DP MCB
6-32A SP MCB
Supply & delivery of 1.1 KV Gr. XLPE/ PVC Armoured Aluminium Cable (KEI/ Gloster / Havells / RR Kabel/ Approved by EIC)
4 core 70 sq. mm.
4 core 35 sq. mm.
4 core 10sq mm
Laying of cable on wall/surface incl. S & F MS saddles with earthing attachment in 2X10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [PWD/GS Page: F-1 Item: 2/b]
Laying of cable 3/3.5/4 core 35 sqmm to 50 sqmm [PWD/GS Page: F-1 Item: 2/c]
Laying of cable 3/3.5/4 core 70 sqmm to 95 sqmm [PWD/GS Page: F-1 Item: 2/d]
Laying of cable upto 3/4 core 25 sqmm [PWD/GS Page: F-1 Item: 2/b]
S & F compression type brass cable gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of XLPE/PVC armoured cable. [PWD/GS Page No.: F-4 Item No.: 7/c]
4 core 35 sq. mm.
4 core 70 sq. mm.
4 core 10sq mm
Finishing the end of the XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & joiting materials. [PWD/GS Page No.: F-5 Item No.: 8/b]
4 core 35 sq. mm.
4 core 70 sq. mm.
4 core 10sq mm
S & F PVC extension Power board with atleast 3 no.s 15 A socket and 3 nos. 15 A piano type switch brand approved by EIC with 6 m length 2.5 SQ 3 core mm unarmoured copper cable cable
Supply & Fixing 18" 4-blades, Metal Body AC wall bracket fan (Orient: Wall-II Tornado/Crompton) on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) on 150mmX300mm best quality vernished wood or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [PWD/GS Page: C-4 Item: 29 ]
Supply & Fixing 48" (1200mm) AC ceiling fan make: (Crompton High Speed/ Orient PSPO NEWBREEZE or SUMMERCOOL ) complete with down rod, canopy fork, blades with all other accessories etc. but without regulator. [PWD/GS Page: C-3 Item: 21/a] Supply & fixing additional safety arrangement of ceiling fan by stranded GI strain wire of suitable gauge with one end fixed at RC clamp with special type of socket, nut-bolts, thimbles which throughly crimped with the strain wire and the wire passing through down rod (for upto 8 ft) and also other end connected with armature spindle by its existing jam nut hole with special arrangement (sample approved by EIC). The length of the strain wire up to 9ft also considering any type of work required i.e. enlarging the existing hole by file etc. to complete the job including installation as per direction of EIC (Static & Dynamic Load Test (in rotation of 1:20) certificate must be provided with final bill jointly with concerned Junior Engineer & authorised Electrical Supervisor of Agency).
S&F Electronic Socket type fan regulator on existing switch board with backelight top cover after making housing for regulator knob by cutting backelight top cover including making necessary connections. [Make: Anchor] [PWD/GS Page: E-6 Item: 18/a ]
S & installation of complete system group control 12 channel Annunciator with indicating arrangement with necessary E. I work as per direction of EIC Make: Max
S & F 250 V AC/Dcsuperior type call bell( Anchor - 8320) on HW Board incl. S&F of HW board
S&F double 4ft LED tube light fitting incl. 2 nos. 4ft LED tube lamp (LTT8-20), With complete cover like defuser. complete with all accessories suspended from ceiling/beem with L-clamp/ beem clamp. [Crompton: IGP132LT8-16 / Philips/Havells/] [PWD/GS Page: C-2 Item: 17]
S&F LED Spot light 20w 360 degree rotation on wooden block on wall ( Make - Phillips / Crompton/Havells/Equivalent )
S&F EPC make 9" Sweep A.C Exhaust fan incl. making hole on wall with nuts & bolts of required with S&F of louver shutter.
S&F EPC make 12" Sweep A.C Exhaust fan incl. making hole on wall with nuts & bolts of required with S&F of louver shutter.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire, with an average depth of 3.65 Mts. below the ground level (For soft Soil: ISI-Medium GI pipe) [PWD/GS Page No.: G-1 Item No.:2/a]
Excavation of soil for installation of Earth Electrode and filling & ramming. (Soft Soil) [PWD/GS Page: G-1 Item:1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe [PWD/GS Page: G-2 Item: 3/a]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode [PWD/GS Page: G-2 Item: 3/b]
S&F earth busbar of galvanized (Hot Dip) MS flat on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [PWD/GS Page: G-2 Item: 4/a]
S&F galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall
Connecting the equipments body to earth busbar including S&F galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat [PWD/GS Page:G-3 Item: 5/d]
S & F of L&T On Load Change Over Switch 415 V 125A on Angle Iron Frame with SS Enclosure with front operated handle
Supply & fixing Sintex loop box of size 250 x 200 x 105 (Syntex: GSJB-2520) with half round clamp on pole and supply & fixing a best quality 80A, 4-pole barrier terminal ainside it including all accessories.
M/S INDRADEEP ENTERPRISE
EVERGREEN ENGINEERS CO OP CONSTRUCTION SOCIETY LTD
BIMALA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .