Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC Agreement executed | |
| 2 | L2₹36.6 L+₹2.2 L (6.26%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹36.6 L+₹2.2 L (6.42%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹38.0 L+₹3.6 L (10.5%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹38.4 L+₹3.9 L (11.5%)Rejected-Finance ORUMBIKUNNIL THURUTHICADU P O MALLAPPALLY PATHANAMTHITTA 689597 | MALLAPPALLY | PATHANAMTHITTA | KERALA | 689597 | L5 | Rejected-Finance L1 |
Tender Value
₹40.7 L
EMD Value
₹50,000
Closing Date
23 Jul 2021, 6:00 pmClosed
EE LSGD
LSGD DIVISION JILLA PANCHAYAT PATHANAMTHITTA 689645
LAC ADS Thiruvalla Assembly 14298 constituency Culvert construction in Vettikal Padi Postoffice padi road
2021_LSGD_426661_5
04/2021-22/EE/LSGD/PTA
Open Tender
Civil Works - Others
Item Rate
300 days
Pathanamthitta
Please refer tender documents
7 documents required · 7 mandatory
₹2,500
₹50,000
Yes
15 Oct 2022
15 Jul 2021
28 Jul 2021
15 Jul 2021
23 Jul 2021
15 Jul 2021
Amount
CULVERT
15.12.3 : Cutting of branches of trees shrubs and trimming of grass and weeds Trimming of grass and weeds from the shoulders/berms and disposing off the same to suitable locations as per technical specifications Clause 1914
11.1.1.1 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth
11.4.1.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203I.P.C.C grade M 10(i)Nominal mix 1:3:6
12.5.1.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mI.P.C.C grade M 15(i)Nominal mix (1:2.5:5)
12.7 : Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
12.5.3 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 m III.R.C.C grade M 20
13.1.2 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25
13.3 : Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
3.14 : Construction of Subgrade and Earthen Shoulders<br> Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
4.11.2 : Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal. Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. <br>(ii) Using Gravel mix soil.
75.8.1 : Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification (i) Nominal mix (1:2:4)
10.11 : Boundary PillarReinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
13.20.2 : Providing and laying parapet with PCC M 15 as per drawing & technical specifications Clauses 800 and 1208.4II.Nominal Mix (1:2.5:5)
11.8 : Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
11.4.3.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203III.P.C.C. grade M 20 (i)Nominal mix (1:2:4)
14.8 : Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
12.9 : Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
12.10.1 : Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8I)Granular material
od1264536/2021_2022 : Providing And Fixing of Good Quality Granite Name Board with Lettering Including of all cost,conveyance,labour charges etc Complete
Superstructure
14.1.A.1.A : Furnishing and Placing Reinforced Cement Concrete Grade M20 Using Concrete Mixer as per drawing and Technical Specification. For solid slab super-structure - Height upto 5m
George Kuruvilla
BIJU MATHEW
SABU K.S.
O.M MATHEW
Bidder Name
George Kuruvilla
SABU K.S.
O.M MATHEW
BIJU MATHEW
J CHANDY
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_610237.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .