Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹401.7 CrAccepted-AOC 1C 1D VINDHYA TELELINKS LIMITED UDYOG VIHAR REWA MADHYA PRADESH 486006 | REWA | MADHYA PRADESH | 486006 | ₹401.7 Cr | 1 | Accepted-AOC Lowest |
| 2 | 2₹419.0 CrRejected-Finance 175 2 SOUTH STATE BANK NAGAR CHETTIPALAYAM ERODE TAMIL NADU 638002 | ERODE | TAMIL NADU | 638002 | ₹419.0 Cr | 2 | Rejected-Finance Second lowest |
| 3 | 3₹423.7 CrRejected-Finance UNIT NO 12 4 MERLIN ACROPOLLS 12TH FLOOR 1858 1 RAJDANGA MAIN ROAD KOLKATA 700107 WB | KOLKATA | WEST BENGAL | 700107 | ₹423.7 Cr | 3 | Rejected-Finance Third lowest |
Tender Value
₹386.1 Cr
EMD Value
₹5 Cr
Closing Date
23 Sept 2024, 4:00 pmClosed
Chief Engineer(Distribution South)
O/o the Chief Engineer, Distribution South, Power house Building, Thiruvananthapuram -695036
Development of Distribution Infrastructure at Thiruvananthapuram, Kollam, Pathanamthitta and Kottayam District of Kerala under the Revamped Reforms-based and Results-linked, Distribution Sector Scheme -Turnkey Basis
2024_KSEB_680838_1
KSEB/CEDS/ep06/RDSS/2024-25 dated 17.07.2024
Open Tender
Electrical Works
300 days
TVPM, Kollam, Pathanamthitta, Kottayam
Refer tender Documents
8 documents required · 8 mandatory
₹17,700
₹5 Cr
Yes
O/o the Chief Engineer, Distribution South
21 Mar 2025
18 Jul 2024
27 Sept 2024
18 Jul 2024
23 Sept 2024
29 Jul 2024
25 Jul 2024
BOQ 1- 11 KV Reconductoring using Covered Conductor
using AAAC 99 sqmm Covered conductor
Covered conductor HT AAAC 99 sqmm conforming to EN 50397 - 1 2020
PSC Pole 9m
A pole 11 m
A pole 12 m
11 kV COMPOSITE POLYMERIC PIN INSULATOR
11 kV V cross arm with GI clamps Bolt & Nut with washers
Pole Top Bracket -F Type GI -11 kV
Disc insulator 11 kV composite polymeric
Hardware fittings ( Tension clamp assembly) for HT covered conductor suitable for 99 Sqmm
Mid span joint set for HT covered conductor suitable for 99 Sqmm - 1 set = 3 nos
Single core outdoor termination kit for HT covered conductor suitable for 99 Sqmm 1 set = 3 nos
Insulated piercing connector set for covered conductor HTsuitable for 99 Sqmm ( Bare to Covered conductor & Covered conductor to Covered conductor)
Helical UV plastic tie
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM
Channel cross arm GI 75x40x6mm 1.8M- with GI- Clamp Bolt & Nut with washers
Channel cross arm GI 75 x 40 x 6 mm 2.4 mt- with GI Clamp Bolt & Nut with washers
CROSS ARM GI CHANNEL 2 LINE (2 Line Channel Cross Arm) with Clamp, Bolt & Nut and washers
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp Bolt & Nut and washers
Composite type polymeric PIN INSULATOR 415V
SHACKLE INSULATOR 415V (WITH STRAP BOLT&NUT)
G.I.WIRE. 4MM (8 SWG)
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia - 2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 5. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work.
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 Sq.mm - GI etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
Bolt & Nut (GI ) with washers of various sizes as per requirement
RDSS sign Board as per approved spec
AB switch,11KV 400A, Composite polymer housing
4 Legged lattice structure
A pole 14 m
RECONDUCTING OF 11 KV OH LINE USING ABC 3x120+1x95 sqmm cable
Aerial Bunched Cable HT 3x120 + 1x95 sq.mm (Insulated Messenger)
Pole PSC 9 M
A pole 11 m
A pole 12 m
Anchoring /Dead end Clamp Assembly for HT AB Cables up to 120 sq.mm
Suspension Clamp Assembly for HT AB Cables up to 120 sq.mm
Stainless Steel Strap 20mmX0.7mm along with Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm] as per requirement
MVT Kit For HT ABC- 1 set = 3 Nos
Heat Shrinkable Termination Kit (3 Nos) for 120 Sq.mm Three phase Aerial Bunched Cable
Channel cross arm GI 75 x 40 x 6mm 2.4 m with GI- Clamp Bolt & Nut with washers
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM
CROSS ARM GI CHANNEL 2 LINE (2 Line Channel Cross Arm) with Clamp, Bolt & Nut and washers
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp Bolt & Nut and washers
Composite type polymeric PIN INSULATOR 415V
SHACKLE INSULATOR 415V (WITH STRAP BOLT&NUT)
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
G.I.WIRE. 4MM (8 SWG)
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia - 2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) with RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 5. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work.
Bolt & Nut (GI ) with washers of various sizes as per requirement
RDSS sign Board as per approved spec
New 11 kV line using ABC 3x120+1x95 sqmm cable
Aerial Bunched Cable HT 3x120 + 1x95 sq.mm (Insulated Messenger)
Pole PSC 9 M
A pole 11 m
Anchoring /Dead end Clamp Assembly for HT AB Cables up to 120 sq.mm
Suspension Clamp Assembly for HT AB Cables up to 120 sq.mm
Stainless Steel Strap [20 mm x 0.7 mm] with adeqaute no. of Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm]
MVT Kit For HT ABC- 1 set = 3 Nos
Heat Shrinkable Termination Kit (3 Nos) for 120 Sq.mm Three phase Aerial Bunched Cable
Channel cross arm GI 75 x 40 x 6mm 2.4 m with GI- Clamp Bolt & Nut with washers
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
GI WIRE 6MM DIA 4 SWG
GI Stay Set includes 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
G.I.WIRE. 4MM (8 SWG)
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel starp and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia - 3 m Length( Earth Pipe) 2. Earth Chamber (PVC) With RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 5. Stainless Steel starp and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work.
Bolt & Nut (GI ) with washers of various sizes as per requirement
RDSS Sign Board as per approved spec
A Pole 12M
A Pole 13M
Channel cross arm GI 75 x 40 x 6 mm 1.8m
4 legged lattice structure
Replacement of old/frayed conductor: 11 kV line using ABC 3x150+1x120 sqmm cable
Aerial Bunched Cable HT 3x150 + 1x120 sq.mm (Insulated Messenger)
Pole PSC 9 M
A pole 11 m
A pole 12 m
Anchoring /Dead end Clamp Assembly for HT AB Cables up to 150 sq.mm
Suspension Clamp Assembly for HT AB Cables up to 150 sq.mm
Stainless Steel Strap 20mmX0.7mm along with Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm] as per requirement
MVT Kit For HT ABC- 1 set = 3 Nos
Heat Shrinkable Termination Kit (3 Nos) for 150 Sq.mm Three phase Aerial Bunched Cable
Channel cross arm GI 75 x 40 x 6mm 2.4 m with GI- Clamp Bolt & Nut with washers
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM
GI Stay Set includes 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
G.I.WIRE. 4MM (8 SWG)
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel starp and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia - 3 m Length( Earth Pipe) 2. Earth Chamber (PVC) With RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 5. Stainless Steel starp and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work.
RDSS Sign Board as per approved spec
CROSS ARM GI CHANNEL 2 LINE (2 Line Channel Cross Arm) with Clamp, Bolt & Nut and washers
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp Bolt & Nut and washers
Composite type polymeric PIN INSULATOR 415V
SHACKLE INSULATOR 415V (WITH STRAP BOLT& NUT)
Bolt & Nut (GI ) with washers of various sizes as per requirement
Air Break Switch(AB Switch) 11kV 400A,Composite Polymer Housing
A Pole 10mtr
Provision for New ABC: New 11 kV line using ABC 3x150+1x120 sqmm cable
Aerial Bunched Cable HT 3x150 + 1x120 sq.mm (Insulated Messenger)
Pole PSC 9 M
A pole 11 m
Anchoring /Dead end Clamp Assembly for HT AB Cables up to 150 sq.mm
Suspension Clamp Assembly for HT AB Cables up to 150 sq.mm
Stainless Steel Strap 20mmX0.7mm along with Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm] as per requirement
MVT Kit For HT ABC- 1 set = 3 Nos
Heat Shrinkable Termination Kit (3 Nos) for 150 Sq.mm Three phase Aerial Bunched Cable
Channel cross arm GI 75 x 40 x 6mm 2.4 m with GI- Clamp Bolt & Nut with washers
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM
GI Stay Set includes 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
G.I.WIRE. 4MM (8 SWG)
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel starp and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia - 3 m Length( Earth Pipe) 2. Earth Chamber (PVC) With RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 5. Stainless Steel starp and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work.
RDSS sign Board as per approved spec
A pole 12 m
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
GI WIRE 6MM DIA 4 SWG
Bolt & Nut (GI ) with washers of various sizes as per requirement
Construction of new 11 kV line using XLPE 3 C x 300 sqmm UG cable
Cable 11kV XLPE AL UG 3 C X300 sq mm (Armoured)
Pole PSC 9 M
Pipe HDPE 110 mm PN 6 configuration and PE grade 80
GI Pipe 150mm Class B 4.8 mm thick GI pipe
Cable End Termination Kit 11 kV XLPE 3 C x 300 Sq.mm -Heat Shrinkable (Outdoor)
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
CROSS ARM GI CHANNEL 100X50 x 10 mm 2.4 M with GI- Clamp Bolt & Nut with washers
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM
GI WIRE ( 6mm DIA 4 SWG & 4 mm DIA 8 SWG)
Bolt & Nut (GI ) with washers of various sizes as per requirement
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia - 2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) etc as required as per technical specification, approved drawings and scope of work.
RDSS Sign Board as per approved spec
Cable Straight Joint Kit for 11 kV XLPE 3 C x 300 Sq.mm -Heat Shrinkable straight joints using Shear Bolt Type as per IS 13573 Part II 2011 with dual wall and single triple extruded hybrid tubing with shear bolt connector as per IEC 61238 of rating 300/400 A
Channel cross arm GI 75 x 40 x 6 mm 2.4 mt with GI- Clamp Bolt & Nut with washers
Constructing New LT line: using ABC - 3 x 70 + 1 x 50 + 1 x 16 sqmm
Aerial Bunched Cable LT 3x70 + 1x50 + 1x16 sq.mm (Insulated Messenger)
Pole PSC 8 M
Anchoring /Dead end Clamp Assembly for LT AB Cables up to 70 sq.mm
Suspension Clamp Assembly for LT AB Cables up to 70 sq.mm
Stainless Steel Strap 20mmX0.7mm along shall also be supplied as per requirement
Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm] shall also be supplied as per requirement
Pre insulated Bi metallic lug for 70 sqmm with brass nut and bolt
Pre insulated Bi metallic lug for 50 sqmm with brass nut and bolt
Pre insulated Bi metallic lug for 16 sqmm with brass nut and bolt
Distribution Box for Service Connection
Satellite connector for service connection Main:16sqmm to 95sqmm,Tap:2.5 sqmm to 35sqmm(4 way)
Insulation Piercing Connector ( IPC Connector): For ABC to Distributio box & other service connection Main 16 sq mm to 70 sq mm; Tap 4 sq.mm to 35 sq.mm
Insulation Piercing Connector (IPC Connector): For ABC to ABC/ Bare Main 16 sq mm to 70 sq mm; Tap 16 sq.mm to 70 sq.mm
Insulation Piercing Connector ( IPC Connector): For ABC to service connection/street light/Earthing Main 16 sq mm to 70 sq mm; Tap 1.5 sq.mm to 10 sq.mm
1.1 kV 1 C x 25 sqmm unarmoured PVC Al cable
GI wire-7/4.00mm(8 SWG) 3ph service connection
GI wire-7/3.15mm(10 SWG) 1ph service connection
GI Stay Set includes ( LT) 1. Stay Insulator Porcelain 11 k V - 1 Nos 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia - 2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 5. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work.
RDSS Sign Board as per approved spec
Replacement of old/frayed conductors: Reconductoring of LT Line using ABC - 3 x 70 + 1 x 50 + 1 x 16 sqmm
Aerial Bunched Cable LT 3x70 + 1x50 + 1x16 sq.mm (Insulated Messenger)
Pole PSC 8 M
Pole PSC 9 M
A Pole 11 M
Suspension Clamp Assembly suitable for insulated messenger of sizes 70 sq.mm, 50 sqmm & 35 Sqmm.
Anchoring /Dead end Clamp Assembly suitable for insulated messenger of sizes 70 sq.mm, 50 sqmm & 35 Sqmm.
Stainless Steel Strap 20mmX0.7mm along shall also be supplied as per requirement
Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm] shall also be supplied as per requirement
Pre-insulated Bi metallic lug for 70 Sqmm with brass nut and bolt
Pre-insulated Bi metallic lug for 50 Sqmm with brass nut and bolt
Pre-insulated Bi metallic lug for 16 Sqmm with brass nut and bolt
1.1 kV 1C X 25 sqmm unarmoured PVC Al Cable
Distribution Box for service connection
Satellite connector for service connection Main:16sqmm to 95sqmm,Tap:2.5 sqmm to 35sqmm(4 way)
Insulation Piercing Connector ( IPC Connector): For ABC to Distribution box & other service connection Main 16 sqmm to 70 sqmm; Tap 4 sq.mm to 35 sq.mm
Insulation Piercing Connector (IPC Connector): For ABC to ABC/Bare Main 16 sq mm to 70sq mm; Tap 16 sq.mm to 50 sq.mm
Insulation Piercing Connector ( IPC Connector): For ABC to service connection/street light/Earthing Main 16 sq mm to 70 sq mm; Tap 1.5 sq.mm to 10 sq.mm
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
11 kV COMPOSITE POLYMERIC PIN INSULATOR
11 kV V cross arm with GI Clamps, Bolt & Nuts with washers
Pole Top Bracket -F Type GI -11 kV
Channel cross arm GI 75x40x6mm 1.8M- with GI- Clamp Bolt & Nut with washers
GI Stay Set includes (LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11 k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 5. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work.
RDSS Sign Board as per approved spec
GI Wire 4 MM (8 SWG)
IPC Main: 16 sq mm to 95 sq mm tap 1.5 sq mm to 35 sq mm (4 way)
Bolt & Nut (GI) with washers of various sizes
Reconductoring of LT Line with ABC 3X95+1X70+1X16 sqmm
Aerial Bunched Cable LT 3x95 + 1x70 + 1x16 sq.mm (Insulated Messenger)
Pole PSC 8 M
Pole PSC 9 M
A Pole 11 M
Suspension Clamp Assembly suitable for insulated messenger of sizes 70 sq.mm, 50 sqmm & 35 Sqmm.
Anchoring /Dead end Clamp Assembly suitable for insulated messenger of sizes 70 sq.mm, 50 sqmm & 35 Sqmm.
Stainless Steel Strap 20mmX0.7mm along with Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm] shall also be supplied as per requirement
Pre-insulated Bi metallic lug for 95 sqmm with brass nut and bolt
Pre-insulated Bi metallic lug for 70 Sqmm with brass nut and bolt
Pre-insulated Bi metallic lug for 16 Sqmm with brass nut and bolt
1.1 kV 1C X 25 sqmm unarmoured PVC Al Cable
Distribution Box for service connection
Satellite connector for service connection Main:16sqmm to 95sqmm,Tap:2.5 sqmm to 35sqmm(4 way)
Insulation Piercing Connector ( IPC Connector): For ABC to Distribution box & other service connection Main 16 sq mm to 95 sq mm; Tap 4 sq.mm to 35 sq.mm
Insulation Piercing Connector (IPC Connector): For ABC to ABC/Bare Main 16 sq mm to 95 sq mm; Tap 16 sq.mm to 95 sq.mm
Insulation Piercing Connector ( IPC Connector): For ABC to service connection/street light/Earthing Main 16 sq mm to 95 sq mm; Tap 1.5 sq.mm to 10 sq.mm
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
11 kV COMPOSITE POLYMERIC PIN INSULATOR
11 kV V cross arm with GI Clamps, Bolt & Nuts with washers
Pole Top Bracket -F Type GI -11 kV
Channel cross arm GI 75x40x6mm 1.8M- with GI- Clamp Bolt & Nut with washers
GI Stay Set includes (LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11 k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
G.I.WIRE. 4MM (8 SWG)
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 5. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work.
RDSS Sign Board as per approved spec
Conversion of LT Sph line to 3 Ph lines with ABC using 3X95+1x70+1x16sqmm
Aerial Bunched Cable LT 3x95 + 1x70 + 1x16 sq.mm (Insulated Messenger)
Pole PSC 8 M
Pole PSC 9 M
A Pole 11 M
Suspension Clamp Assembly suitable for insulated messenger of sizes 70 sq.mm, 50 sqmm & 35 Sqmm.
Anchoring /Dead end Clamp Assembly suitable for insulated messenger of sizes 70 sq.mm, 50 sqmm & 35 Sqmm.
Stainless Steel Strap 20mmX0.7mm along with Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm] shall also be supplied as per requirement
Pre-insulated Bi metallic lug for 95 sqmm with brass bolt & nut
Pre-insulated Bi metallic lug for 70 Sqmm with brass bolt & nut
Pre-insulated Bi metallic lug for 50 Sqmm with brass bolt & nut
Pre-insulated Bi metallic lug for 16 Sqmm with brass bolt & nut
1.1 kV 1C X 25 sqmm unarmoured PVC Al Cable
Distribution Box for service connection
Satellite connector for service connection Main:16sqmm to 95sqmm,Tap:2.5 sqmm to 35sqmm(4 way)
Insulation Piercing Connector ( IPC Connector): For ABC to Distributio box & other service connection Main 16 sq mm to 95 sq mm; Tap 4 sq.mm to 35 sq.mm
Insulation Piercing Connector (IPC Connector): For ABC to ABC/Bare Main 16 sq mm to 95 sq mm; Tap 16 sq.mm to 95 sq.mm
Insulation Piercing Connector ( IPC Connector): For ABC to service connection/street light/Earthing Main 16 sq mm to 95 sq mm; Tap 1.5 sq.mm to 10 sq.mm
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
11 kV COMPOSITE POLYMERIC PIN INSULATOR
11 kV V cross arm with GI Clamps, Bolt & Nuts with washers
Pole Top Bracket -F Type GI -11 kV
Channel cross arm GI 75x40x6mm 1.8M- with GI- Clamp Bolt & Nut with washers
GI Stay Set includes ( LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11 k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
G.I.WIRE. 4MM (8 SWG)
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 5. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work.
RDSS Sign Board as per approved spec
Installation of New Transformer
Installation of 100 kVA Transformer
Distribution Transformer 3 Phase 100 kVA 11kV/433 V ONAN - Level 1
Pole PSC 9 M
Pole PSC 8 M
A Pole - 11 M
Distribution Box LT Outdoor 2 Way 200 A as per technical specification
Conductor ACSR Rabbit
Conductor ACSR Racoon
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Composite type polymeric PIN INSULATOR 415V
SHACKLE INSULATOR 415V (WITH STRAP BOLT&NUT)
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes (LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Pole Top Bracket -F Type GI -11 kV with Clamp, Bolt & Nut and washers
V cross arm GI 11 kV with Clamp, Bolt & Nut
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
Channel cross arm GI 75x40x6mm 1.8M with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Channel cross arm GI 75x40x6mm 2.4M
Earthing coil GI 115 turns 50mm internal dia
Arial Bunched Cable HT 3x120 + 1 x95 sq.mm ( Insulated messenger)
MVT Kit for ABC
Heat Shrinkable Termination kit (3Nos) for 120 Sq mm Three phase Areal Bunched Cable
Anchoring/Dead end clamp assembly for HT AB Cables up to 120 sq.mm
Pole A type GI 12M
Installation of New Transformer
Installation of 160 kVA Transformer
Distribution Transformer 3 Phase 160 kVA 11kV/433 V ONAN - Level 1
Pole PSC 9 M
Pole PSC 8 M
Distribution Box LT Outdoor 3 Way 200 A as per technical specification
Conductor ACSR Rabbit
Conductor ACSR Racoon
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes (LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
Channel cross arm GI 75x40x6mm 1.8M with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Cable 1.1 kV XLPE AL 1c X 185 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Installation of New Transformer
Installation of 250 kVA Transformer
Distribution Transformer 3 Phase 250 kVA 11kV/433 V ONAN - Level 1
Distribution Box LT Outdoor 3 Way 200 A as per technical specification
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Cable 1.1 kV XLPE AL 1c X 180 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Enhancement of Transformers
ENHANCEMENT OF 25 kVA to 100 kVA TRANSFORMER
Distribution Transformer 3Ph 100kVA, 11kV/433V ONAN- Level 1
PSC Pole 9 m
Distribution Box 415V 200A 2 way Outdoor
Conductor ACSR Rabbit
Conductor ACSR Racoon
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM/ insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
V cross arm GI 11 kV with Clamp, Bolt & Nut
Pole Top Bracket -F Type GI -11 kV with Clamp, Bolt & Nut and washers
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
Channel cross arm GI 75x40x6mm 1.8M with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Enhancement of Transformers
ENHANCEMENT OF 63 kVA to 100kVA TRANSFORMER
Distribution Transformer 3Ph 100kVA, 11kV/433V ONAN - Level 1
PSC Pole 9 m
A Pole - 11 M
Distribution Box 415V 200A 2 way Outdoor
Conductor ACSR Rabbit
Conductor ACSR Racoon
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
V cross arm GI 11 kV with Clamp, Bolt & Nut
Pole Top Bracket -F Type GI -11 kV with Clamp, Bolt & Nut and washers
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
Channel cross arm GI 75x40x6mm 1.8M with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Enhancement of Transformers
ENHANCEMENT OF 100 kVA to 160 kVA TRANSFORMER
Distribution Transformer 3Ph 160kVA, 11kV/433V ONAN- Level 1
PSC Pole 9 m
A Pole - 11 M
Distribution Box 415V 200A 3 way Outdoor
Conductor ACSR Rabbit
Conductor ACSR Racoon
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
V cross arm GI 11 kV with Clamp, Bolt & Nut
Pole Top Bracket -F Type GI -11 kV with Clamp, Bolt & Nut and washers
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
Channel cross arm GI 75x40x6mm 1.8M with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Cable 1.1 kV XLPE AL 1c X 185 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Enhancement of Transformers
ENHANCEMENT OF 160 kVA to 250 kVA TRANSFORMER
Distribution Transformer 3Ph 250 kVA, 11kV/433V ONAN- Level 1
Distribution Box 415V 200A 3 way Outdoor
Conductor ACSR Rabbit
Conductor ACSR Racoon
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Cable 1.1 kV XLPE AL 1c X 300 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Cable 1.1 kV XLPE AL 1c X 180 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Enhancement of Transformers
ENHANCEMENT OF 250 kVA to 315 kVA TRANSFORMER
Distribution Transformer 3Ph 315 kVA, 11kV/433V ONAN- Level 1
Distribution Box 415V 200A 4 way Outdoor
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Cable 1.1 kV XLPE AL 1c X 300 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Cable 1.1 kV XLPE AL 1c X 180 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Enhancement of Transformers
ENHANCEMENT OF 100 kVA to 250 kVA TRANSFORMER
Distribution Transformer 3Ph 250 kVA, 11kV/433V ONAN- Level 1
Distribution Box 415V 200A 3 way Outdoor
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Cable 1.1 kV XLPE AL 1c X 180 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
REPLACEMENT OF AGED TRANSFORMERS
Replacement of 11 KV/ 433 V , 100 KVA Aged Transformer.
Distribution Transformer 3 Phase 100 kVA 11kV/433 V ONAN - Level 1
A Pole - 11 M
Distribution Box LT Outdoor 2 Way 200 A as per technical specification
Conductor ACSR Rabbit
Conductor ACSR Racoon
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes (LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Pole Top Bracket -F Type GI -11 kV with Clamp, Bolt & Nut and washers
V cross arm GI 11 kV with Clamp, Bolt & Nut
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
Channel cross arm GI 75x40x6mm 1.8M with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
REPLACEMENT OF AGED TRANSFORMERS
Replacement of 11 KV/ 433 V , 160 KVA Aged Transformer.
Distribution Transformer 3 Phase 160 kVA 11kV/433 V ONAN - Level 1
Pole PSC 9 M
A Pole - 11 M
Distribution Box LT Outdoor 3 Way 200 A as per technical specification
Conductor ACSR Rabbit
Conductor ACSR Racoon
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes (LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Pole Top Bracket -F Type GI -11 kV with Clamp, Bolt & Nut and washers
V cross arm GI 11 kV with Clamp, Bolt & Nut
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
Channel cross arm GI 75x40x6mm 1.8M with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Cable 1.1 kV XLPE AL 1c X 185 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
REPLACEMENT OF AGED TRANSFORMERS
Replacement of 11 KV/ 433 V , 250 KVA Aged Transformer.
Distribution Transformer 3 Phase 250 kVA 11kV/433 V ONAN - Level 1
Distribution Box LT Outdoor 3 Way 200 A as per technical specification
Conductor ACSR Rabbit
Conductor ACSR Racoon
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Cable 1.1 kV XLPE AL 1c X 300 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
REPLACEMENT OF AGED TRANSFORMERS
Replacement of 11 KV/ 433 V ,500 KVA Aged Transformer.
Distribution Transformer 3Ph 500 kVA, 11kV/433V ONAN- Level 1
Distribution Box 415V 200A 4 way Outdoor
Conductor ACSR Rabbit
Conductor ACSR Racoon
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Cable 1.1 kV XLPE AL 1c X 300 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Installation of HVDS Transformer
Installation of 16 kVA HVDS Transformer
16 kVA HVDS Transformer
Pole PSC 9 M
Distribution Box for service connection
Conductor ACSR Rabbit
Conductor ACSR Racoon
Aerial Bunched Cable LT 3x50 + 1x35 + 1x16 sq.mm (Insulated Messenger)
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Pole Top Bracket -F Type GI -11 kV with Clamp, Bolt & Nut and washers
V cross arm GI 11 kV with Clamp, Bolt & Nut
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
Channel cross arm GI 75x40x6mm 1.8M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 16 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Installation of HVDS Transformer
Installation of 25 kVA HVDS Transformer
25 kVA HVDS Transformer
Pole PSC 9 M
Pole PSC 8 M
Distribution Box for service connection
Conductor ACSR Rabbit
Conductor ACSR Racoon
Aerial Bunched Cable LT 3x50 + 1x35 + 1x16 sq.mm (Insulated Messenger)
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes (LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Pole Top Bracket -F Type GI -11 kV with Clamp, Bolt & Nut and washers
V cross arm GI 11 kV with Clamp, Bolt & Nut
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
Channel cross arm GI 75x40x6mm 1.8M with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 16 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Installation of HVDS Transformer
Installation of 63 kVA HVDS Transformer
63 kVA HVDS Transformer
Pole PSC 9 M
Pole PSC 8 M
Distribution Box LT Outdoor 2 Way 200 A as per technical specification
Aerial Bunched Cable LT 3x50 + 1x35 + 1x16 sq.mm (Insulated Messenger)
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
COMPOSITE PIN INSULATOR 11 kV with Pin
Composite type polymeric PIN INSULATOR 415V
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes (LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
Pole Top Bracket -F Type GI -11 kV with Clamp, Bolt & Nut and washers
Composite polymeric type Drop out fuse 11 kV
Cable 1.1 kV XLPE AL 1c X 50 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
PROVISION OF DISASTER RESELIENT INFRASTRUCTURE WORKS
Uplifting of Transformer foundation
A Pole 11 m
A Pole 12 m
Distribution Box 415V 200A 2 way Outdoor
Distribution Box 415V 200A 3 way Outdoor
Conductor ACSR Rabbit
Conductor ACSR Racoon
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM/ insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
V cross arm GI 11 kV with Clamp, Bolt & Nut
Pole Top Bracket -F Type GI -11 kV with Clamp, Bolt & Nut and washers
Composite polymeric type Drop out fuse 11 kV
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
Channel cross arm GI 75x40x6mm 1.8M with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
PROVISION OF DISASTER RESELIENT INFRASTRUCTURE WORKS
Relocating Transformers
A Pole 11 m
Distribution Box 415V 200A 3 way Outdoor
Conductor ACSR Rabbit
Conductor ACSR Racoon
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
COMPOSITE PIN INSULATOR 11 kV with Pin
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM/ insulating brackets etc
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
V cross arm GI 11 kV with Clamp, Bolt & Nut
Pole Top Bracket -F Type GI -11 kV with Clamp, Bolt & Nut and washers
Composite polymeric type Drop out fuse 11 kV
Channel Cross arm for LT 2 Pin -GI 75 x 40 x 6 mm-0.510 mt (2 line Cross arm)- with Clamp , Bolt & Nut
CROSS ARM GI CHANNEL 100X50 mm 3 M with Clamp , Bolt & Nut
Cable 1.1 kV XLPE AL 1c X 120 sq mm (Un Armoured) cable with palm type crimping socket of suitable sizes
Bolt & Nut GI of various sizes with washers
Danger Board 250 x 200 mm (11000 V) with all mounting accessories
RDSS Sign Board as per specification
Installation ofCapacitor Bank
9 KVAR LT Capacitor with shunt reactor for harmonics filtering with enclouser and connecting copper wires and all pole mounting accessories
Replacement of old/frayed conductor: 11 kV OH Line with ACSR Raccoon using PSC Poles
Conductor ACSR Racoon
Pole PSC 9 M
A pole 11 m
A pole 12 m
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
11 kV COMPOSITE PIN INSULATOR
11 kV V cross arm with GI Clamps, Bolt & Nuts with washers
Pole Top Bracket -F Type GI -11 kV
Channel cross arm GI 75x40x6mm 1.8M- with GI- Clamp Bolt & Nut with washers
Channel cross arm GI 75x40x6mm 2.4M- with GI- Clamp Bolt & Nut with washers
LT 2 pin channel cross arm with GI- Clamp Bolt & Nut with washers
Shackle Insulator 415V (with strap Bolt & Nut)
Composite Polymeric Pin Insulator 415V
LT 4 pin channel cross arm with GI- Clamp Bolt & Nut with washers
GI Stay Set includes 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI WIRE (4 mm DIA 8 SWG)
Bolt & Nut (GI ) with washers of various sizes as per requirement
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc. as required as per technical specification, approved drawings and scope of work.
RDSS Sign Board as per specification
Replacement of old/frayed conductors: Reconductoring of LT Line with Bare ACSR conductor OH ( Rabbit )
Pole PSC 8 M
Pole PSC 9 M
Conductor ACSR Rabbit
SHACKLE INSULATOR 415V SET(WITH STRAP BOLT&NUT)
COMPOSITE POLYMERIC PIN INSULATOR 415V
LT CROSS ARM GI CHANNEL 4 LINE with Clamp, Bolt & Nut .
LT CROSS ARM 2 LINE SET WITH CLAMP BOLT & NUT.
11 kV COMPOSITE POLYMERIC PIN INSULATOR
11 kV V cross arm with GI Clamps, Bolt & Nuts with washers
Pole Top Bracket -F Type GI -11 kV
GI wire 4mm ( 8 SWG)
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI 4. Earth Knob etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes (LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11 k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
Cable 1.1kV XLPE AL 1C X 95 sq mm (Un Armoured)
FUSE UNIT 415 V 100 A PORCELAIN
Base Frame SMC with clamps nuts & bolts for LT Section Fuse neutral Link.
LT LINE SPACERS 4 Line 300 mm
LT LINE SPACERS 2 Line 450 mm
Bolt& Nut GI of various sizes
RDSS sign Board as per approved spec
New LT line: using ABC - 3 x 95 + 1 x 70 + 1 x 16 sqmm
Aerial Bunched Cable LT 3x95 + 1x70 + 1x16 sq.mm (Insulated Messenger)
Pole PSC 8 M
Pole PSC 9 M
Anchoring /Dead end Clamp Assembly for LT AB Cables up to 95 sq.mm
Suspension Clamp Assembly for LT AB Cables up to 95 sq.mm
Stainless Steel Strap 20mmX0.7mm along with Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm] shall also be supplied as per requirement
Pre insulated Bi metallic lug for 95 sqmm with brass nut and bolt
Pre insulated Bi metallic lug for 70 sqmm with brass nut and bolt
Pre insulated Bi metallic lug for 16 sqmm with brass nut and bolt
Distribution Box for Service Connection
Satellite connector for service connection Main:16sqmm to 95sqmm,Tap:2.5 sqmm to 35sqmm(4 way)
Insulation Piercing Connector ( IPC Connector): For ABC to Distributio box & other service connection Main 16 sq mm to 95 sq mm; Tap 4 sq.mm to 35 sq.mm
Insulation Piercing Connector (IPC Connector): For ABC to ABC/Bare Main 16 sq mm to 95 sq mm; Tap 16 sq.mm to 95 sq.mm
Insulation Piercing Connector ( IPC Connector): For ABC to service connection/street light/Earthing Main 16 sq mm to 95 sq mm; Tap 1.5 sq.mm to 10 sq.mm
1.1 kV 1 C x 25 sqmm unarmoured PVC Al cable
G.I.WIRE. 4MM (8 SWG)
GI Stay Set includes (LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia - 2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 5. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work.
RDSS Sign Board as per approved spec
1.Conversion of LT ACSR OH 1 Ph 3 W to 3 ph 5W 2.Conversion of LT ACSR OH 1 Ph 2 W to 3 ph 4W
Conductor ACSR Rabbit
SHACKLE INSULATOR 415V SET(WITH STRAP BOLT&NUT)
LT CROSS ARM GI CHANNEL 4 LINE with Clamp, Bolt & Nut .
LT CROSS ARM 2 LINE SET(WITH CLAMP BOLT&NUT)
8M PSC Pole
9 M PSC Pole
GI Stay Set includes ( LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11 k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Wire 4 mm ( 8 SWG)
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI 4. Earth Knob etc as required as per technical specification, approved drawings and scope of work.
Composite Polymeric PIN INSULATOR 415V
Cable 1.1kV XLPE AL 1C X 95 sq mm (Un Armoured)
FUSE UNIT 415 V 100 A PORCELAIN
Base Frame SMCwith clamps nuts & bolts for LT Section Fuse neutral Link.
LT LINE SPACERS 4 Line 300 mm
LT LINE SPACERS 2 Line 450 mm
Bolt & Nut of various sizes with washer
RDSS sign Board as per approved spec
Conversion of LT Sph line to 3 Ph lines with ABC : 3X70+1X50+1X16 sqmm
Aerial Bunched Cable LT 3x70 + 1x50 + 1x16 sq.mm (Insulated Messenger)
Pole PSC 8 M
Pole PSC 9 M
A Pole 11 M
Suspension Clamp Assembly suitable for insulated messenger of sizes 70 sq.mm, 50 sqmm & 35 Sqmm.
Anchoring /Dead end Clamp Assembly suitable for insulated messenger of sizes 70 sq.mm, 50 sqmm & 35 Sqmm.
Stainless Steel Strap 20mmX0.7mm along with Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm] shall also be supplied as per requirement
Pre-insulated Bi metallic lug for 70 Sqmm with brass bolt & nut
Pre-insulated Bi metallic lug for 50 Sqmm with brass bolt & nut
Pre-insulated Bi metallic lug for 16 Sqmm with brass bolt & nut
1.1 kV 1C X 25 sqmm unarmoured PVC Al Cable
Distribution Box for service connection
Satellite connector for service connection Main:16sqmm to 95sqmm,Tap:2.5 sqmm to 35sqmm(4 way)
Insulation Piercing Connector ( IPC Connector): For ABC to Distributio box & other service connection Main 16 sq mm to 95 sq mm; Tap 4 sq.mm to 35 sq.mm
Insulation Piercing Connector (IPC Connector): For ABC to ABC/Bare Main 16 sq mm to 95 sq mm; Tap 16 sq.mm to 95 sq.mm
Insulation Piercing Connector ( IPC Connector): For ABC to service connection/street light/Earthing Main 16 sq mm to 95 sq mm; Tap 1.5 sq.mm to 10 sq.mm
11 kV COMPOSITE POLYMERIC PIN INSULATOR
11 kV V cross arm with GI Clamps, Bolt & Nuts with washers
Pole Top Bracket -F Type GI -11 kV
GI Stay Set includes ( LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11 k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
G.I.WIRE. 4MM (8 SWG)
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Earth Connector 95 Sqmm 4. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 5. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work.
RDSS Sign Board as per approved spec
IPC - Main: 16 sq mm to 95 sq mm tap 1.5 sq mm to 35 sq mm (4 way)
RMUs : Installation & Commissioning of SCADA compatible Extensible RMUs of various configarations
11kV 630 A SCADA compatible Extensible RMU CCC -Load break switchs 3 nos
11kV 630 A SCADA compatible Extensible RMU CTC - Load break switch 2 nos & VCB 1 No
11kV 630 A SCADA compatible Extensible RMU CC - Load break switchs 2 nos
11kV 630 A SCADA compatible Extensible RMU Add on T - VCB 1 nos
11kV 630 A SCADA compatible Extensible RMU Add on C-Load break switchs 1 nos
11kV 630 A SCADA compatible Extensible RMU CCCTT - Load break switchs 3 nos & VCB 2 nos
CROSS ARM GI CHANNEL 100mmX50 mmx6mm
GI Pipe Earthing set includes 1. GI STRIP 32 X 6 MM 2. Pipe GI 40 mm dia - 2.5 m Length( Earth Pipe) 3. Earth Chamber (PVC) With RCC Covering Slab etc.as required as per technical specification, approved drawings and scope of work.
Bolt & Nut GI of various sizes as per requirement
Cable End Termination Kit 11 kV XLPE 3c x 300 Sq.mm -Heat Shrinkable
RDSS sign board as per aprroved spec
Cable End Termination Kit 11 kV XLPE 3c x 150 Sq.mm -Heat Shrinkable
Cable End Termination Kit 11 kV XLPE 3c x 120 Sq.mm for ABC-Heat Shrinkable
11 kV XLPE 3c x 150 Sq.mm UG Cable
Reconductoring of LT Line with XLPE insulated covered conductor equivalent to ACSR 50sqmm Rabbit conductor
LT Covered conductor equivalent to 50 sqmm ACSR rabbit
Pole PSC 8 M
Pole PSC 9 M
4 line channel cross arm with GI Clamp, Bolt & Nut
2 line channel cross arm with GI Clamp, Bolt & Nut
Composite type polymeric Pin insulator 415 V
Anchoring /Dead end Clamp Assembly suitable for XLPE insulated covered condutor equivalent to ACSR Rabbit 50 Sqmm
Pre-insulated Bi metallic lug for 50 sqmm with brass nut and bolt
Cable Tie UV Plastic Heavy Duty of required Length
Insulation Piercing Connector (IPC Connector) for LT Covered conductor Main: suitable for XLPE insulated covered condutor equivalent to ACSR Rabbit 50 Sqmm ; Tap 4 sq.mm to 35 sq.mm
IPC for LT covered conductor for streelight connection and earthing. Main: suitable for XLPE insulated covered condutor equivalent to ACSR Rabbit 50 Sqmm, tap-1.5 to 10 sqmm
Insulated piercing connector set for LT covered conductor suitable for XLPE insulated covered condutor equivalent to ACSR Rabbit 50 Sqmm for both Main and tap ( Bare to Covered conductor & Covered conductor to Covered conductor)
Distribution Box for service connection
Satellite connector for service connection Main: suitable for XLPE insulated covered condutor equivalent to ACSR Rabbit 50 Sqmm,Tap:2.5 sqmm to 35sqmm (4 way)
1.1 kV 1C X 25sqmm unarmoured PVC Al Cable
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
11 kV COMPOSITE POLYMERIC PIN INSULATOR
11 kV V cross arm with GI Clamps, Bolt & Nuts with washers
Pole Top Bracket -F Type GI -11 kV
Channel cross arm GI 75x40x6mm 1.8M- with GI- Clamp Bolt & Nut with washers
GI Stay Set includes (LT) 1. Stay Insulator Porcelain 11 k V - 2 Nos 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
G.I.WIRE. 4MM (8 SWG)
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
Bolt& Nut (GI )of various sizes with washers
RDSS sign board as per approved spec
Conversion of LT line using XLPE insulated covered conductor equivalent ACSR 50sqmm Rabbit conductor
LT Covered conductor equivalentto 50 sqmm ACSR rabbit
Pole PSC 8 M
Pole PSC 9 M
4 line channel cross arm with GI Clamp, Bolt & Nut
2 line channel cross arm with GI Clamp, Bolt & Nut
Composite type polymeric Pin insulator 415 V
Anchoring /Dead end Clamp Assembly suitable for XLPE insulated covered condutor equivalent to ACSR Rabbit 50 Sqmm
Pre-insulated Bi metallic lug for 50 sqmm with brass nut & bolt
Cable Tie UV Plastic Heavy Duty Length as per requirement
Insulation Piercing Connector (IPC Connector) for LT Covered conductor Main: suitable for XLPE insulated covered condutor equivalent to ACSR Rabbit 50 Sqmm ; Tap 4 sq.mm to 35 sq.mm
IPC for LT covered conductor for street light connection and earthing. Main: suitable for XLPE insulated covered condutor equivalent to ACSR Rabbit 50 Sqmm, tap-1.5 to 10 sqmm
Insulated piercing connector set for LT covered conductor suitable for XLPE insulated covered condutor equivalent to ACSR Rabbit 50 Sqmm for both Main and tap ( Bare to Covered conductor & Covered conductor to Covered conductor)
Distribution Box for service connection
Satellite connector for service connection Main: suitable for XLPE insulated covered condutor equivalent to ACSR Rabbit 50 Sqmm,Tap:2.5 sqmm to 35sqmm (4 way)
1.1 kV 1C X 25sqmm unarmoured PVC Al Cable
GI Stay Set includes ( LT) 1. Stay Insulator Porcelain 11 k V - 1 No 2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11 k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (LT Stay Plate GI) 3. STAY TIGHTNER LT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (LT Stay Rod) 6. Helically formed Guy-Grip LT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
G.I.WIRE. 4MM (8 SWG)
Coil Earth set includes 1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work.
Bolt& Nut (GI )of various sizes with washers
RDSS sign board as per approved spec
LOAD BREAK SWITCH
Cable 11kV XLPE AL UG 3 C X300 sq mm (Armoured)
PSC Pole 9m
CROSS ARM GI CHANNEL 75X40 mm 2.4 M
Channel cross arm GI 75x40x6mm 1.8M- with GI- Clamp Bolt & Nut with washers
GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11k V - 2 Nos 2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI) 3. STAY TIGHTNER HT 4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) 5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod) 6. Helically formed Guy-Grip HT 7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT) 8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work.
GI Pipe Earthing set includes 1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) 2. Earth Chamber (RCC) With RCC Covering Slab 3. Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug) 4. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. 5. Earth wire of suitable sizes 6. SS strap for earthing etc as required as per technical specification, approved drawings and scope of work.
SCADA Compatible CT RMU 11 kV 630 Amps 21 kA for 3 seconds with primary protection CT rating of 100-200/5 Amps (or) 150-300/5 Amps providing OH line protection in T-Limb of the RMU.
Outdoor Cable End Termination suitable for 11Kv 3x300 sqmm XLPE UG cable.
Clamp GI for cable support
Lightning Arrester 9 kV,10 KA (Station class) Composite Polymer Housing 1 set = 3 nos with LA Supporting plate GI of size 500x300x3MM, insulating brackets etc
GI Pipe 150 mm Class B 4.8 mm thick GI pipe with supporting clamps.
Pipe HDPE 125 mm
11 kV Composite Polymeric Disc Insulator with Hardware Fittings and GI Cleat etc.
Conductor ACSR Racoon
Aluminium crimping socket 120 sqmm
Aluminium crimping socket 150 sqmm
Bolt and nut Brass 1 1/2 X 1/2
Bolt and nut GI various sizes
Description of Work / Item(s)
BOQ 2- 11 KV Reconductoring using Covered Conductor
using AAAC 99 sqmm Covered conductor
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Insertion of one HT 'A' type pole in existing OH line including digging & backfilling pit in all classes of soil , fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Providing concrete muffing for A pole of size 0.45x0. 45x1.5m (0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5sides
Renewal of existing damaged/old 11kV PSC/RCC/ Teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items , drawing sufficient length of GI earth leads to the ground for earthing. etc complete including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of existing damaged/old 11kV Stay with complete stay set along with excavation of stay pit in classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one Strut using HT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole, drawing sufficient length of GI earth leads to the ground for earthing including excavation of stay pit in all classes of soil and back filling, erection of complete stay set along with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of any type of existing damaged/old 11kV Strut with new PSC strut in place including excavation & backfilling of pit, consolidating, dismantling and refitting of all items including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Dismantling (without damage) 11 kV line (Three conductors) /LT line including dismantling cross arm, insulators, disc, spacers, disconnecting jumper connection etc & disconnection of service connection where ever necessary & rolling the conductor and stacking the materials and then transporting safely to the KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Stringing of 11 kV line with Covered conductor HT 99 sqmm conforming to EN 50397 - 1 2020 (3 conductors) after fitting insulators, binding conductors to pin insulators using helical UV plastic tie suitable for any neck dia, fixing disc insulators and anchoring with anchoring clamps including cut point works.The works also includes 1. Touching clearance where ever necessary 2. Doing straight joint on HT covered conductor 99 Sqmm using the mid span jointing kit as per specification. 3. Doing one cable end termination on HT covered conductor 99 Sqmm using the cable jointing kit as per specification. 4. Re erection of dismantled LT lines and all associated materials ( including street light fittings) / re connection of dismantled service connections whereever necessary. 5. Straightening of poles wherever necessary. 6. Installation of Insulation piercing connector ( Bare to Covered conductor & Covered conductor to Covered conductor) for branching suitable for HT Covered conductor 99 Sqmm etc
Erection of 11kV LA set ( 3 Nos) with supporting plates and giving all connections etc including cost of earth strip - GI ( 25 x 3mm) and its drawal.
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure all classes of soil& backfilling.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Dismantling (without damage) one 11kV PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Renewal of existing damaged/old 11kV PSC/RCC Pole with new 'A' type pole in place including excavation, erection of new pole, backfilling pit and refitting of all items etc. and conveyance of all materials except pole.
Renewal of existing damaged/old 11kV PSC/RCC Pole with new Four legged lattice structure in place including excavation, erection of new pole, backfilling pit and refitting of all items etc. and conveyance of all materials except pole.
Fitting and erecting one HT PSC Pole in position,including fitting cross arm and back filling pit in ordinary ordinarysoil drawing sufficient length GI leads from F clamp through V cross arm to the ground for Earthing
Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays,strut etc. attached thereon and stacking the Same.
Dismantling (without damage) one 11kV A type pole after disconnecting stays,strut etc. attached thereon and stacking the Same.
Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing.
Fitting and errecting HT double pole using A type pole including fitting 2 Nos of channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing)
RECONDUCTING OF 11 KV OH LINE USING ABC 3x120+1x95 sqmm cable
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Renewal of existing damaged/old 11kV PSC/RCC Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items, drawing sufficient length of GI earth leads to the ground for earthing etc complete including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Insertion of one HT 'A' type pole in existing OH line including digging & backfilling pit in all classes of soil , fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing).
Providing concrete muffing for A pole of size 0.45x0.45x1.5m (0.5 m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5 sides
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of existing damaged/old 11kV Stay with complete stay set along with excavation of stay pit in classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one Strut using HT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole, drawing sufficient length of GI earth leads to the ground for earthing including excavation of stay pit in all classes of soil and back filling, erection of complete stay set along with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of any type of existing damaged/old 11kV Strut with new PSC strut in place including excavation & backfilling of pit, consolidating, dismantling and refitting of all items including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Dismantling (without damage) 11 kV line (Three conductors) /LT line including dismantling cross arm, insulators, disc, spacers, disconnecting jumper connection etc & disconnection of service connection where ever necessary & rolling the conductor and stacking the materials and then transporting safely to the KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Stringing of 11 kV Aerial bunched cable of size 3 x 120 + 1 x 95 sqmm with insulated Messenger through existing poles/ newly inserted pole providing loop where ever necessay and tieing the cables using UV plastic tie -Heavy Duty of Length as per standard( including cost of plastic tie).The work also includes 1. Touching clearance where ever necessary. 2. Erection of Anchoring clamp / suspension clamp 3. Installation of MVT and its terminal connections where ever necessary 4.Straightening of poles wherever necessary 5. Re erection of dismantled LT lines and all associated materials ( including street light fittings) / re connection of dismantled service connections whereever necessary etc
Doing one cable end termination on HT ABC of sizes Up to 3x150+1x120 sqmm
Erection of 11kV LA set ( 3 Nos) with supporting plates and giving all connections etc including cost of earth strip- GI ( 25 x 3mm) and its drawal.
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in all classes of soil & backfilling.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Provision for New ABC: New 11 kV line using ABC 3x120+1x95 sqmm cable
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Fitting and erecting one HT PSC Single Pole in position, fitting cross arm if needed, digging and back filling pit in all classes of soil (as per standards), drawing sufficient length of GI earthing leads to the ground for earthing etc.(excluding provision of earthing)
Fitting and erecting one HT 'A' type Single Pole in position, fitting cross arm if needed, digging and back filling pit inall classes ofsoil (as per standards), drawing sufficient length of GI earthing leads to the ground for earthing (excluding provision of earthing)
Providing concrete muffing of size 0.45x0.45x1.5m (0.5 m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5 sides
Fitting and erecting one HT Double Pole Structure using PSC pole in position including fitting channel cross arms, digging and back filling pit in all classes of soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing).
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 2 Nos) and .2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole, drawing sufficient length of GI earth leads to the ground for earthing including excavation of stay pit in all classes of soil and back filling, erection of complete stay set along with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc.
Stringing of 11 kV Aerial bunched cable of size 3 x 120 + 1 x 95 sqmm with insulated Messenger through existing poles/ newly inserted pole providing loop where ever necessay and tieing the cables using UV plastic tie- Heavy Duty 500 mm Length ( including cost of plastic tie). Erection of Anchoring clamp / suspension clamp and installation of MVT where ever necessary etc shall form part of the work.
Doing one cable end termination on HT ABC of sizes Up to 3x150+1x120 sqmm
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in classes of soil & backfilling.
Providing one Earth using GI earth pipe of size 40mm dia,3 m length including digging separate pit (0.45X0.45X3 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder, Charcol etc)
Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing.
Erection of 11kV LA set ( 3 Nos) with supporting plates and giving all connections etc including cost of earth strip ( 25 x 3mm) and its drawal.
Fitting and providing one Strut using HT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Insertion of one HT PSC pole in existing OH line including digging and backfilling pit in ordinary soil ,fitting cross arm,insulators bindings etc.drawing sufficient lengh of GI earth leads to the ground for earthing ( excluding provision for earthing )
Fitting and erecting one HT Double PoleStructure using 'A' type pole in positionincluding fitting 2 No. channel cross arm,digging and back filling pit in ordinary soil,drawing sufficient length of GI earthing leadsthrough all cross arms to the ground forearthing (excluding provision of earthing).
Fitting and erecting one HT Four legged lattice structure in position including fittingcross arm, digging and back filling pit in ordinary soil (as per standards), drawingsufficient length of GI earthing leads from Fclamp through V cross arm to theground forearthing (excluding provision of earthing).
Insertion of one HT 'A' type pole in existing OH line including digging & backfilling pit in all classes of soil , fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing).
Dismantling (without damage) one LTPSC/RCC pole after disconnecting stays,strut etc. attached thereon and stacking the same.
Replacement of old/frayed conductor: 11 kV line using ABC 3x150+1x120 sqmm cable
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm , insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Renewal of existing damaged/old 11kV PSC/RCC Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items , drawing sufficient length of GI earth leads to the ground for earthing. etc complete including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Insertion of one HT 'A' type pole in existing OH line including digging & backfilling pit in all classes of soil , fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing).
Providing concrete muffing for A pole of size 0.45x0.45x1.5m (0.5 m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5 sides
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 2 Nos) and .2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of existing damaged/old 11kV Stay with complete stay set along with excavation of stay pit in classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 2 Nos) and .2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one Strut using HT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Dismantling (without damage) 11 kV line (Three conductors) /LT line including dismantling cross arm, insulators, disc, disconnecting jumper connection, rolling the conductor and stacking the materials and then transporting safely to the KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Stringing of 11 kV Aerial bunched cable of size 3 x 150 + 1 x 120 sqmm with insulated Messenger through existing poles/ newly inserted pole providing loop where ever necessay and tieing the cables using UV plastic tie -Heavy Duty of Length as per standard( including cost of plastic tie).The work also includes 1.Touching clearance where ever necessary 2. Erection of Anchoring clamp / suspension clamp 3. Installation of MVT and its terminal connections where ever necessary 4.Straightening of poles wherever necessary 5. Re erection of dismantled LT lines and all associated materials ( including street light fittings) / re connection of dismantled service connections whereever necessary etc
Doing one cable end termination on HT ABC of sizes Up to 3x150+1x120 sqmm
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in all classes of soil & backfilling.
Providing one Earth using GI earth pipe of size 40mm dia,3 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Erection of 11kV LA set ( 3 Nos) with supporting plates and giving all connections etc including cost of earth strip ( 25 x 3mm) and its drawal.
Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole, drawing sufficient length of GI earth leads to the ground for earthing including excavation of stay pit in all classes of soil and back filling, erection of complete stay set along with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc.
Renewal of any type of existing damaged/old 11kV Strut with new PSC strut in place including excavation & backfilling of pit, consolidating, dismantling and refitting of all items including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and erecting one HT PSC Single Polein position, including fitting cross arm, diggingand back filling pit in ordinary soil (as per standards), drawing sufficient length of GIearthing leads from F clamp through V crossarm to the ground for earthing (excluding provision of earthing).
Fitting and erecting one HT Double PoleStructure using PSC pole in position includingfitting 2 channel cross arms, digging and backfilling pit in ordinary soil, drawing sufficientlength of GI earthing leads through all cross arms to the ground for earthing (excludingprovision of earthing).
Fitting one set AB switch on existing DP,giving connection and drawing sufficientlength of GI earthing leads to the ground for earthing, excluding provision of earthing.
Fitting and erecting one HT A type Pole in Position incl. Fitting cross arm,digging and backfiling pit, drawing earth leads
Renewal of existing damaged/old 11kVPSC/RCC Pole with new 'A' type pole in placeincluding excavation, erection of new pole, backfilling pit and refitting of all items etc. andconveyance of all materials except pole.
Dismantling (without damage) one 11kVPSC/RCC pole after disconnecting stays,strut etc. attached thereon and stacking the same.
Dismantling (without damage) one LTPSC/RCC pole after disconnecting stays,strut etc. attached thereon and stacking the same.
Provision for New ABC: New 11 kV line using ABC 3x150+1x120 sqmm cable
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Fitting and erecting one HT PSC Single Pole in position, fitting cross arm if needed, digging and back filling pit in all classes of soil (as per standards), drawing sufficient length of GI earthing leads to the ground for earthing etc.(excluding provision of earthing)
Fitting and erecting one HT 'A' type Single Pole in position, fitting cross arm if needed, digging and back filling pit inall classes ofsoil (as per standards), drawing sufficient length of GI earthing leads to the ground for earthing (excluding provision of earthing)
Providing concrete muffing of size 0.45x0.45x1.5m (0.5 m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5 sides
Fitting and erecting one HT Double Pole Structure using PSC pole in position including fitting channel cross arms, digging and back filling pit in all classes of soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing).
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 2 Nos) and .2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole, drawing sufficient length of GI earth leads to the ground for earthing including excavation of stay pit in all classes of soil and back filling, erection of complete stay set along with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Stringing of 11 kV Aerial bunched cable of size 3 x 150 + 1 x 120 sqmm with insulated Messenger through existing poles/ newly inserted pole providing loop where ever necessay and tieing the cables using UV plastic tie - Heavy Duty 500 mm Length ( including cost of plastic tie). Errection of Anchoring clamp / suspension clamp and installation of MVT and its termination where ever necessary etc shall form part of the work.
Doing one cable end termination on HT ABC of sizes Up to 3x150+1x120 sqmm
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in classes of soil & backfilling.
Providing one Earth using GI earth pipe of size 40mm dia,3 m length including digging separate pit (0.45X0.45X3 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder, Charcol etc)
Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing.
Erection of 11kV LA set ( 3 Nos) with supporting plates and giving all connections etc including cost of earth strip ( 25 x 3mm) and its drawal.
Fitting and providing one Strut using HT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Construction of new 11 kV line using XLPE 3 C x 300 sqmm UG cable
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Excavation of cable trench of appropriate size ( normally 1.2 m deep and 0.35m/0.5m wide for single /double run) in all classes of soil including breaking clods, watering,rammimg and sectioning of soil bank etc and back filling the soil after cable laying and consolidating the soil in layer of 75 cm( excluding laying of cable). The cost includes temporary restoration charges along NH with 1:3:6 CC
Additional rate for excavation of cable trench in exceptionally hard conditions ( like in *ordinary rock).
Charges for HDD including survey of site information collection regarding underground Utilities, survey of utilities, pit marking,pilot drilling Pre-reaming pulling 110 mm dia HDPE pipe ( includes cost of HDPE pipe, temporary restoration charges for HDD pit with 1:3:6 CC etc.)
Laying HT XLPE UG cable of sizes beyond 3x185 sq mm and upto and including 3x300 sqmm including conveying cable Store/stacking place to work site and laying it carefully using cable rollers, taking through stone ware/G.I.pipes at road crossing/culverts/bridges etc.and through already laid HDPE pipe of size 110 mm &160 mm (for Railway crossing) whereever necessary, providing identification tags at 5m intervals, filling the space around the cable with riddled soil and covering the top with concrete slabs providing cable route markers at 100 m intervals, inclusive of cost of all materials (other than cost of GI/HDPE pipe & UG Cable), labour and transport including crane charges excluding excavation and backfilling.
Mounting and connecting HT XLPE UG cable ends of all sizes upto and including 3x300 sq mm with special type cable clamps, bolts, nuts, terminal protectors etc.including cost of extra materials if needed and giving necessary jumper connections.
Doing one cable end termination on HT XLPE UG cables of sizes beyond 3x185 sqmm and upto and including 3x300 sq mm using the cable jointing kit after baricading, caution board and all other safety measures including charges for cable jointer etc. complete as per the direction of the departmental officers.
Fitting and erecting one HT PSC Single Pole in position, including fitting cross arm, digging and back filling pit in all classes of soil (as per standards), drawing sufficient length of GI earthing leads to the ground for earthing etc (excluding provision of earthing).
Fitting and erecting one HT Double Pole Structure using PSC pole in position including fitting 2 channel cross arms, digging and back filling pit in all classes of soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing).
Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing.
Erection of 11kV LA set ( 3 Nos) with supporting plates and giving all connections etc including cost of earth strip- GI ( 25 x 3mm) and its drawal.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Doing straight joint on HT XLPE UG cables of sizes beyond 3x185 sqmm and upto and including 3x300 sq mm using the cable jointing kit as per specification after providing proper traffic signalling and caution board fencing etc. wherever necessary, including charges for cable jointer and other sundries etc. as per the direction of departmental officers at site.
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP including conveyance of materials.
Constructing New LT line: using ABC - 3 x 70 + 1 x 50 + 1 x 16 sqmm
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Erecting one LT PSC Pole in position including digging & back filling pit in all classes of soil.
Erection of complete stay set LT along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Fitting and providing one Strut using LT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil , including the cost of Strut clamp.
Drawing, Testing and commissioning of LT AB cable. Stringing of 1.1 kV Aerial bunched cable 3 x 70 + 1 x 50 + 1 x 16 Sqmm with insulated Messenger through existing/renewed poles, erection of tension clamp for dead ends, suspension clamps , installation of IPCs of various types and satellite connectors where ever necessary. The work also includes the following 1.Touching clearance where ever necessary.. 2. UV plastic tie for binding conductors ( Including cost of plastic tie) 3. Providing end caps ( Including cost of end caps) 4. Installation of pre insulated mid span joints of sizes 16 sqmm, 50 Sqmm,70 sqmm as per field requirement( Including cost of pre insulated mid span joints). 5. Pole numbering as per standards 6. Installation of pre insulated bi metallic lugs at transformer points & other fuse points etc
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in all classes of soil & backfilling.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Fitting of one No. pole top service connection box of standard size - up to 4 way (3 phase connection -4 Nos or 1 Ph connection - 12 Nos ) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height including giving connections
Reconductoring of LT Line using ABC - 3 x 70 + 1 x 50 + 1 x 16 sqmm
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Dismantling & Re connecting (without damage) LT - Single /three phase OH line conductor by dismantling cross arms, insulators, spacers , jumper connections etc and stacking the conductors in rolls properly including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.The work also includes dismantling of branch circuit, service connection, street light etc
Single phase Two wire
Single phase Three wire
Three phase Four wire
Three phase Five wire
Insertion of one LT PSC pole in existing Single/three phase OH line including digging & back filling pit in all classes of soil, binding etc. drawing sufficient length of GI earth leads to the ground for earthing.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm , insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Insertion of one HT 'A' type pole in existing OH line including digging & backfilling pit in all classes of soil , fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing).
Providing concrete muffing for A pole of size 0.45x0.45x1.5m (0.5 m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5 sides
Renewal of existing damaged/old LT PSC/RCC/teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items etc . Conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL is also form part of the work.
Renewal of existing damaged/old 11kV PSC/RCC/ Teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items , drawing sufficient length of GI earth leads to the ground for earthing. etc complete including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Erection of complete LT stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Renewal of existing damaged/old LT stay with complete stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of existing damaged/old 11kV Stay with complete stay set along with excavation of stay pit in classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Providing Strut using LT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Drawing, Testing and commissioning of LT AB cable. Stringing of 1.1 kV Aerial bunched cable with insulated Messenger through existing/renewed poles including erection of tension clamp for dead ends, suspension clamps , installation of IPCs of various types and satellite connectors where ever necessary. The work also includes the following 1. Touching clearance where ever necessary . 2. UV plastic tie for binding the conductors ( Including cost of plastic tie) 3. Providing end caps ( Including cost of end caps) 4. Installation of pre insulated mid span joints of sizes 16 sqmm, 35Sq.mm, 50 Sqmm,70 sqmm & 95 sqmm as per field requirement( Including cost of pre insulated mid span joints). 5. Reconnection of service connection, branch circuit lines, street light & re erection of dismantled 11kV lines where ever necessary 6. Straightening of poles where ever necessary. 7. Installation of pre insulated bi metallic lugs at transformer points & other fuse points etc. using 3 x 70 + 1 x 50+1x 16 sqmm with insulated Messenger
Fitting of one No. pole top service connection box of standard size - up to 4 way (3 phase connection -4 Nos or 1 Ph connection - 12 Nos ) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height including giving connections
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in all classes soil & backfilling.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Fitting and providing one Strut using HT PSC pole including digging and back filling pit inn ordinary soil.
Providing Fly stay for LT pole using LT PSC pole, drawing sufficient length of GI earth leads to the ground for earthing including excavation of stay pit in all classes of soil and back filling, erection of complete stay set along with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc.
Dismantling (without damage)one 11KVPSC/RCC pole after disconnecting stays,strut etc.attached thereon and stacking the same.
Reconductoring of LT Line with ABC 3X95+1X70+1X16 sqmm
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Dismantling (without damage) 11 kV/LT - Single /three phase OH line conductor by dismantling cross arms, insulators, spacers , jumper connections etc and stacking the conductors in rolls properly including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.The work also includes dismantling of branch circuit, service connection, street light etc
Single phase Two wire
Single phase Three wire
Three phase Four wire
Three phase Five wire
Insertion of one LT PSC pole in existing Single/three phase OH line including digging & back filling pit in all classes of soil, binding etc. drawing sufficient length of GI earth leads to the ground for earthing.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm , insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Insertion of one HT 'A' type pole in existing OH line including digging & backfilling pit in all classes of soil , fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing).
Providing concrete muffing for A pole of size 0.45x0.45x1.5m (0.5 m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5 sides
Renewal of existing damaged/old LT PSC/RCC/teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items etc . Conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL is also form part of the work.
Renewal of existing damaged/old 11kV PSC/RCC/ Teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items , drawing sufficient length of GI earth leads to the ground for earthing. etc complete including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Erection of complete LT stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Renewal of existing damaged/old LT stay with complete stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of existing damaged/old 11kV Stay with complete stay set along with excavation of stay pit in classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Providing Fly stay for LT pole using LT PSC pole, drawing sufficient length of GI earth leads to the ground for earthing including excavation of stay pit in all classes of soil and back filling, erection of complete stay set along with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc.
Providing Strut using LT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Drawing, Testing and commissioning of LT AB cable. Stringing of 1.1 kV Aerial bunched cable with insulated Messenger through existing/renewed poles including erection of tension clamp for dead ends, suspension clamps , installation of IPCs of various types and satellite connectors where ever necessary. The work also includes the following 1. Touching clearance where ever necessary . 2. UV plastic tie for binding the conductors ( Including cost of plastic tie) 3. Providing end caps ( Including cost of end caps) 4. Installation of pre insulated mid span joints of sizes 16 sqmm, 35Sq.mm, 50 Sqmm,70 sqmm & 95 sqmm as per field requirement( Including cost of pre insulated mid span joints). 5. Reconnection of service connection, branch circuit lines, street light & re erection of dismantled 11kV lines where ever necessary 6. Straightening of poles where ever necessary. 7. Installation of pre insulated bi metallic lugs at transformer points & other fuse points etc.
3 x 95 + 1 x 70+1x 16 sqmm with insulated Messenger
Fitting of one No. pole top service connection box of standard size - up to 4 way (3 phase connection -4 Nos or 1 Ph connection - 12 Nos ) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height including giving connections
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in all classes soil & backfilling.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Dismantling (without damage) one 11kVPSC/RCC pole after disconnecting stays,strut etc. attached thereon and stacking the same.
Fitting and erecting one HT 'A' type Single Pole in position, including fitting cross arm,digging and back filling pit in ordinary soil (asper standards), drawing sufficient length of GIearthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing).
Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Fitting and erecting one HT PSC Single Polein position, including fitting cross arm, diggingand back filling pit in ordinary soil (as perstandards), drawing sufficient length of GI earthing leads from F clamp through V crossarm to the ground for earthing (excludingprovision of earthing).
Conversion of LT Sph line to 3 Ph lines with ABC using 3X95+1x70+1x16sqmm
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Dismantling (without damage) 11 kV/LT Single /three phase OH line conductor by dismantling cross arms, insulators, spacers, jumper connections etc and stacking the conductors in rolls properly including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.The work also includes dismantling of branch circuit, service connection, street light etc
Single phase Two wire
Single phase Three wire
Insertion of one LT PSC pole in existing three phase OH line including digging & back filling pit in all classes of soil, binding etc. drawing sufficient length of GI earth leads to the ground for earthing.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm , insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Insertion of one HT 'A' type pole in existing OH line including digging & backfilling pit in all classes of soil , fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing).
Providing concrete muffing for A pole of size 0.45x0.45x1.5m (0.5 m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5 sides
Rnewal of existing damaged/old LT PSC/RCC/teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items etc . Conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL is also form part of the work.
Renewal of existing damaged/old 11kV PSC/RCC/ Teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items , drawing sufficient length of GI earth leads to the ground for earthing. etc complete including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Renewal of existing damaged/old LT stay with complete stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Erection of complete LT stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 1 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of existing damaged/old 11kV Stay with complete stay set along with excavation of stay pit in classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Providing Fly stay for LT pole using LT PSC pole, drawing sufficient length of GI earth leads to the ground for earthing including excavation of stay pit in all classes of soil and back filling, erection of complete stay set along with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc.
Providing Strut using LT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Drawing, Testing and commissioning of LT AB cable. Stringing of 1.1 kV Aerial bunched cable with insulated Messenger through existing/renewed poles, erection of tension clamp for dead ends, suspension clamps , installation of IPCs of various types and satellite connectors where ever necessary. The work also includes the following 1. Touching clearance where ever necessary . 2. UV plastic tie for binding the conductors ( Including cost of plastic tie) 3. Providing end caps ( Including cost of end caps) 4. Installation of pre insulated mid span joints of sizes 16 sqmm, 35Sq.mm, 50 Sqmm,70 sqmm & 95 sqmm as per field requirement( Including cost of pre insulated mid span joints). 5. Reconnection of service connection, branch circuit lines, street light & re erection of dismantled 11kV lines where ever necessary 6. Straightening of poles where ever necessary 7. Installation of pre insulated bi metallic lugs at transformer points & other fuse points etc.
3 x 95 + 1 x 70+1x 16 sqmm with insulated Messenger
Fitting of one No. pole top service connection box of standard size - up to 4 way (3 phase connection -4 Nos or 1 Ph connection - 12 Nos ) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height including giving connections
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in all classes soil & backfilling.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Installation of Transformers
Installation of 100 kVA Transformer
Erection of one 100 kVA Transformer in DP structure using PSC pole. The work includes the following 1. Fitting and erecting one HT Double Pole Structure using PSC pole in position digging and back filling pit in all classes of soil,muffing as per standard,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on DP structure/plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Erection of one 100 kVA Transformer in DP structure using A pole. The work includes the following 1. Fitting and erecting one HT Double Pole Structure using A pole in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles/plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Erection of complete stay set LT along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Insertion of one LT PSC pole in existing three phase OH line including digging & back filling pit in all classes of soil, fitting cross arm,insulator, binding etc.
Constructing Single Pillar/mushroom foundation for mounting transformer as per drawing and specificationapproved by KSEBL.
Erection of 100 kVA transformer,Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles/plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Errection of one HT PSC pole including digging & back filling pit in all classes of soil, fitting cross arm,insulator, binding etc.
Insertion of one HT 'A' type pole in existing OH line including digging & backfilling pit in all classes of soil , fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing. (all 'A' type poles includs)
Providing concrete muffing for A pole of size 0.45x0. 45x1.5m (0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5sides
Installation of Transformers
Installation of 160 kVA Transformer
Erection of one 160 kVA Transformer in DP structure using PSC pole. The work includes the following 1. Fitting and erecting one HT Double Pole Structure using PSC pole in position digging and back filling pit in all classes of soil,muffing as per standard,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC ,, etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles/plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Erection of complete stay set LT along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials
Cleaning and levelling of transformer yard, spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Insertion of one LT PSC pole in existing Three phase OH line including digging & back filling pit in all classes of soil, fitting cross arm,insulator, binding etc.
Constructing Double Pillar/mushroom foundation for mounting transformer as per drawing and specificationapproved by KSEBL.
Erection of 160 kVA transformer, Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles/plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Providing one Coil Earth using No.8 SWG GI earth wire ( 50mm dia,115 turns )including digging seperate pit (0.45 x0.45 x1.5 m) at standard distance away from the pole /structure in ordinary soil and back filling.
Stringing of 11 kV Aerial bunched cable of size 3 x 120 + 1 x 95 sqmm with insulated Messenger through existing poles/ newly inserted pole providing loop where ever necessay and tieing the cables using UV plastic tie -Heavy Duty of Length as per standard ( including cost of plastic tie)). The work also includes 1. Touching clearance where ever necessary 2. Erection of Anchoring clamp / suspension clamp 3. Installation of MVT and its terminal connections where ever necessary 4. Pole numbering as per standards etc
Providing concrete muffing of size 0.45x0.45x1.5m (0.5m above GL and 1m below GL).Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3)12mm 0.45x0.45mx5sides.
Insertion of one HT PSC pole in existing OH line including digging and backfilling pit in ordinary soil ,fitting cross arm,insulators bindings etc.drawing sufficient lengh of GI earth leads to the ground for earthing ( excluding provision for earthing )
Fitting and erecting one HT PSC pole in position incl. Fitting cross arm digging and backfilling pit,drawing earth leads
Fitting and erecting one HT A Type Pole using including fitting l cross arms, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads
Doing one cable end termination on HT ABC of sizes Up to 3x120+1x95 sqmm
Installation of Transformers
Installation of 250 kVA Transformer
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Cleaning and levelling of transformer yard, spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Constructing Double Pillar/mushroom foundation for mounting transformer as per drawing and specificationapproved by KSEBL.
Erection of 250 kVA transformer, Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles/plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Enhancement of Transformers
ENHANCEMENT OF 25 kVA to 100 kVA TRANSFORMER
Dismantling HT Double Pole Structure (PSC pole/A pole) after disconnecting stay wires, channel cross arms,AB switch, DO fuse, LA, GI earthing leads, DTR meter with box with metering equipment, CTs, Distribution Box, statutory display boards, etc. The work also includes conveyance of the taken back materials to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEBL.
Dismantling existing transformer erected in DP structure ( Apole/PSC pole) and its earthing etc and stacking the taken back transformer and other materials properly . The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Erecting one 100 kVA Transformer to existing DP structure ( PSC/A Pole)/Plinth/Platform. The work includes the following 1. Mounting of transformer DP structure ( PSC/A Pole)/Plinth/Platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 2. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and erecting one HT Double Pole Structure using PSC poles in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) .
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Enhancement of Transformers
ENHANCEMENT OF 63 kVA to 100 kVA TRANSFORMER
Dismantling HT Double Pole Structure (PSC pole/A pole) after disconnecting stay wires, channel cross arms,AB switch, DO fuse, LA, GI earthing leads, DTR meter with box with metering equipment, CTs, Distribution Box, statutory display boards, etc. The work also includes conveyance of the taken back materials to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEBL.
Dismantling existing transformer erected in DP structure ( (PSC pole/A pole) and its earthing etc and stacking the taken back transformer and other materials properly . The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Erecting one 100 kVA Transformer to existing DP structure ( PSC/A Pole)/Plinth/Platform . The work includes the following 1. Mounting of transformer on existing DP structure ( PSC/A Pole)/Plinth/Platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 2. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and erecting one HT Double Pole Structure using PSC poles in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) .
Fitting and erecting one HT Double Pole Structure using A pole in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) .
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Enhancement of Transformers
ENHANCEMENT OF 100 kVA to 160 kVA TRANSFORMER
Dismantling HT Double Pole Structure (PSC pole/A pole) after disconnecting stay wires, channel cross arms,AB switch, DO fuse, LA, GI earthing leads, DTR meter with box with metering equipment, CTs, Distribution Box, statutory display boards, etc. The work also includes conveyance of the taken back materials to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEBL.
Dismantling existing transformer erected in DP structure ( (PSC pole/A pole)/Plinth/Platform and its earthing etc and stacking the taken back transformer and other materials properly . The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Erecting one 160 kVA Transformer to existing DP structure ( PSC/A Pole)/Plinth/Platform. The work includes the following 1. Mounting of transformer on existing DP structure ( PSC/A Pole)/Plinth/Platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 2. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and erecting one HT Double Pole Structure using PSC poles in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) .
Fitting and erecting one HT Double Pole Structure using A pole in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) .
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Constructing Double Pillar/mushroom foundation for mounting transformer as per drawing and specificationapproved by KSEBL.
1. Erection of 160 kVA transformer, Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles/plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Enhancement of Transformers
ENHANCEMENT OF 160 kVA to 250 kVA TRANSFORMER
Dismantling existing transformer erected in DP structure (PSC pole/A pole)/Plinth/Platformand its earthing etc and stacking the taken back transformer and other materials properly . The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Erecting one 250 kVA Transformer to existing Plinth/Platform. The work includes the following 1. Mounting of transformer on existing Plinth/Platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 2. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and erecting one HT Double Pole Structure using PSC poles in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) .
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Providing Transformer fencing using steel work using 40 mm Dia GI pipes for verticals & outer frame of gate, providing gate with locking arrangements, with two horizontal bracings using 40 x 6 mm MS flat & grills with MS rods 8 mm Dia @ 10cm c/c for verticals for the gate, providing danger board & name board, fixing in position, concreting the base with 1:2:4 CC, applying one coat of zinc chromate primer and two coats of aluminium paint for fencing post and gate frame, providing fencing with 4 mm GI chain link fixed to GI post, as per detailed specifications including all charges and cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Constructing Transformer plinth of size 1.5x1.5x1.5m on 1.8x1.8x0.75m basement inclusive of cost of all materials. [Excavation 1.8x1.8x0.75m, Random Rubble in CM(1:6) 1.8x1.8x0.75m + 1.5x1.5x1.5m, concrete (1:2:4, 20mm) 1.5x1.5x0.10 m, plaster CM (1:3) 12mm, 1.5x1.5m, Pointing CM (1:3) 1.5x1.5mx 4 sides].
Constructing Double Pillar/mushroom foundation for mounting transformer as per drawing and specificationapproved by KSEBL.
Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles/plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Enhancement of Transformers
ENHANCEMENT OF250 kVA to 315 kVA TRANSFORMER
Dismantling transformer erected in DP structure/Plinth/Platform and its earthing etc and stacking the taken back transformer and other materials properly . The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
1. Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles/plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Enhancement of Transformers
ENHANCEMENT OF 100 kVA to 250 kVA TRANSFORMER
Dismantling transformer erected in DP structure/Plinth/Platform and its earthing etc and stacking the taken back transformer and other materials properly . The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Constructing Double Pillar/mushroom foundation for mounting transformer as per drawing and specificationapproved by KSEBL.
1.Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles/plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
REPLACEMENT OF AGED TRANSFORMERS
Replacement of 11 KV/ 433 V , 100 KVA Aged Transformer/ Replacement of 63 kVA transformer with 1 No. 11 KV/ 433 V , 100 KVA Transformer
Dismantling HT Double Pole Structure (PSC pole/A pole) after disconnecting stay wires, channel cross arms,AB switch, DO fuse, LA, GI earthing leads, DTR meter with box with metering equipment, CTs, Distribution Box, statutory display boards, etc. The work also includes conveyance of the taken back materials to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEBL.
Dismantling transformer erected in DP structure/Plinth/Platform and its earthing etc and stacking the taken back transformer and other materials properly . The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Erecting one 100 kVA Transformer to existing DP structure/Plinth/Platform. The work includes the following 1. Mounting of transformer on existing DP structure/Plinth/Platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 2. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and erecting one HT Double Pole Structure using A pole in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) .
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Providing Transformer fencing using steel work using 40 mm Dia GI pipes for verticals & outer frame of gate, providing gate with locking arrangements, with two horizondal bracings using 40 x 6 mm MS flat & grills with MS rods 8 mm Dia @ 10cm c/c for verticals for the gate, providing danger board & name board, fixing in position, concreting the base with 1:2:4 CC, applying one coat of zinc chromate primer and two coats of aluminium paint for fencing post and gate frame, providing fencing with 4 mm GI chain link fixed to GI post, as per detailed specifications including all charges and cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Constructing Single Pillar/mushroom foundation for mounting transformer as per drawing and specificationapproved by KSEBL.
REPLACEMENT OF AGED TRANSFORMERS
Replacement of 11 KV/ 433 V , 160 KVA Aged Transformer.
Dismantling HT Double Pole Structure (PSC pole/A pole) after disconnecting stay wires, channel cross arms,AB switch, DO fuse, LA, GI earthing leads, DTR meter with box with metering equipment, CTs, Distribution Box, statutory display boards, etc. The work also includes conveyance of the taken back materials to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEBL.
Dismantling transformer erected in DP structure/Plinth/Platform and its earthing etc and stacking the taken back transformer and other materials properly . The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Erecting one 160 kVA Transformer to existing DP structure/Plinth/Platform. The work includes the following 1. Mounting of transformer on existing DP structure/Plinth/Platform. using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 2. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and erecting one HT Double Pole Structure using PSC poles in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) .
Fitting and erecting one HT Double Pole Structure using A pole in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) .
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Providing Transformer fencing using steel work using 40 mm Dia GI pipes for verticals & outer frame of gate, providing gate with locking arrangements, with two horizontal bracings using 40 x 6 mm MS flat & grills with MS rods 8 mm Dia @ 10cm c/c for verticals for the gate, providing danger board & name board, fixing in position, concreting the base with 1:2:4 CC, applying one coat of zinc chromate primer and two coats of aluminium paint for fencing post and gate frame, providing fencing with 4 mm GI chain link fixed to GI post, as per detailed specifications including all charges and cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Constructing Double Pillar/mushroom foundation for mounting transformer as per drawing and specificationapproved by KSEBL.
REPLACEMENT OF AGED TRANSFORMERS
Replacement of 11 KV/ 433 V , 250 KVA Aged Transformer.
Dismantling transformer erected in DP structure/Plinth/Platform and its earthing etc and stacking the taken back transformer and other materials properly . The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Erecting one 250 kVA Transformer to existing Plinth/Platform. The work includes the following 1. Mounting of transformer on existing plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 2. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Constructing Double Pillar/mushroom foundation for mounting transformer as per drawing and specificationapproved by KSEBL.
REPLACEMENT OF AGED TRANSFORMERS
Replacement of 11 KV/ 433 V , 500 KVA Aged Transformer.
Dismantling transformer erected in DP structure/Plinth/Platform and its earthing etc and stacking the taken back transformer and other materials properly . The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Erecting one 500 kVA Transformer to existing Plinth/Platform. The work includes the following 1. Mounting of transformer on existing plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 2. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing using steel work using 40 mm Dia GI pipes for verticals & outer frame of gate, providing gate with locking arrangements, with two horizontal bracings using 40 x 6 mm MS flat & grills with MS rods 8 mm Dia @ 10cm c/c for verticals for the gate, providing danger board & name board, fixing in position, concreting the base with 1:2:4 CC, applying one coat of zinc chromate primer and two coats of aluminium paint for fencing post and gate frame, providing fencing with 4 mm GI chain link fixed to GI post, as per detailed specifications including all charges and cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Installation of HVDS Transformer
Installation of 16 kVA HVDS Transformer
Erection of one HVDS 16 kVA Transformer in DP structure using PSC pole. The work includes the following 1. Fitting and erecting one HT Double Pole Structure using PSC pole in position digging and back filling pit in all classes of soil,muffing as per standard,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box for service connections , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles using Transformer Side Belting Angle (cost includes), making cut points using Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables from LT transformer terminals to distribution box.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Installation of HVDS Transformer
Installation of 25 kVA HVDS Transformer
Erection of one HVDS 25 kVA Transformer in DP structure using PSC pole. The work includes the following 1. Fitting and erecting one HT Double Pole Structure using PSC pole in position digging and back filling pit in all classes of soil,muffing as per standard,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box for service connections , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles using Transformer Side Belting Angle (cost includes), making cut points using Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables from LT transformer terminals to distribution box.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Installation of HVDS Transformer
Installation of 63 kVA HVDS Transformer
Erection of one HVDS 63 kVA Transformer in DP structure using PSC pole. The work includes the following 1. Fitting and erecting one HT Double Pole Structure using PSC pole in position digging and back filling pit in all classes of soil,muffing as per standard,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box, drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) . 2. Mounting of transformer on poles using Transformer Side Belting Angle (cost includes), making cut points using Disc set,pin insulator , PG clamp etc and giving connections etc. 3. Routing of LT cables from both LT transformer terminals to distribution box and from distribution box to pole top ( already erected)
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Erection of complete stay set LT along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Insertion of one LT PSC pole in existing three phase OH line including digging & back filling pit in all classes of soil, fitting cross arm,insulator, binding etc.
PROVISION OF DISASTER RESELIENT INFRASTRUCTURE WORKS
Uplifting of Transformer foundation ( General format for 100/160/250 kVA. Please modify the format according to the requirement)
Dismantling HT Double Pole Structure (PSC pole/A pole) after disconnecting stay wires, channel cross arms,AB switch, DO fuse, LA, GI earthing leads, DTR meter with box with metering equipment, CTs, Distribution Box, statutory display boards, etc. While dismantling, the reusable materials shall be separately stacked and transported to the new location without any damage. The quality of reusable materials shall be ensured before erecting at new site.The work also includes conveyance of the taken back materials to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEBL.
Dismantling transformer erected in DP structure/Plinth/Platform and its earthing etc and stacking the taken back transformer and other materials properly . While dismantling, the reusable materials including transformer shall be separately stacked and transported to the new location without any damage. The quality of reusable materials shall be ensured before erecting at new site.The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Erecting one Transformer ( 100/160/250 kVA) to existing Plinth/Platform. The work includes the following 1. Mounting of transformer on existing plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 2. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and erecting one HT Double Pole Structure using A pole in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) .
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and 0.2 cu.m concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Construction of suitable masonary platform with approach if required (steps) for easy acess to the distribution transformer and associated equipments.
PROVISION OF DISASTER RESELIENT INFRASTRUCTURE WORKS
Relocating Transformers ( General format for 100/160/250 kVA. Please modify the format according to the requirement)
Dismantling HT Double Pole Structure (PSC pole/A pole) after disconnecting stay wires, channel cross arms,AB switch, DO fuse, LA, GI earthing leads, DTR meter with box with metering equipment, CTs, Distribution Box, statutory display boards, etc. While dismantling, the reusable materials shall be separately stacked and transported to the new location without any damage. The quality of reusable materials shall be ensured before erecting at new site.The work also includes conveyance of the taken back materials to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEBL.
Dismantling transformer erected in DP structure/Plinth/Platform and its earthing etc and stacking the taken back transformer and other materials properly . While dismantling, the reusable materials including transformer shall be separately stacked and transported to the new location without any damage. The quality of reusable materials shall be ensured before erecting at new site.The work also includes the conveyance of the taken back materials including transformer to KSEBL store safely and stacking the same properly with proper documentation as directed by concerned officials of KSEB
Erecting one Transformer ( 100/160/250 kVA) to existing Plinth/Platform. The work includes the following 1. Mounting of transformer on existing plinth/platform using Transformer Side Belting Angle (cost includes), making cut points uing Disc set,pin insulator , PG clamp etc and giving connections etc. 2. Routing of LT cables through cable trays of dimensions as per specification ( Cable Tray GI (Perforated) 300 x 30 x 1.6mm) from LT transformer terminals to both distribution box and to the pole top ( erected for drawig LT lines) including cost of cable trays, spacers etc.
Fitting and erecting one HT Double Pole Structure using A pole in position digging and back filling pit in all classes of soil,muffing as per standard & Specification ,Fitting channel cross arms ,AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines /Covered conductor/ABC etc., Fixing distribution box with LT fuse units , drawing sufficient length of GI earthing leads to the ground for earthing where ever necessary. Independent neutral earth leads and LA earth leads using GI flat strip of suitable sizes (cost includes) to be used as per tender specification and shall be routed through alkathene tube ( cost includes) .
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and 0.2 cu.m concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of materials.
Cleaning and levelling of transformer yard , spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Installation of Capacitor Bank
Installation of 9 KVAR LT (440V) capacitor with shunt reactor in the existing pole and giving connections etc
Replacement of old/frayed conductor: 11 kV OH Line with ACSR Raccoon using PSC Poles
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Insertion of one HT 'A' type pole in existing OH line including digging & backfilling pit in all classes of soil , fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Providing concrete muffing for A pole of size 0.45x0. 45x1.5m (0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5sides
Renewal of existing damaged/old 11kV PSC/RCC/Teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items etc complete including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one Strut using HT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 2 Nos) and .2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of existing damaged/old 11kV Stay with complete stay set along with excavation of stay pit in classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 2 Nos) and .2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Dismantling (without damage) 11 kV line (Three conductors) /LT line including dismantling cross arm, insulators, disc, disconnecting jumper connection, rolling the conductor and stacking the materials and then transporting safely to the KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Stringing of 11kV line with ACSR Raccoon (Three conductors) after fitting insulators (Hellically formed distribution top tie shall be used for binding conductor with pin insulators) , providing disc sets at cut points and giving jumper connections including cutting and removing tree branches wherever necessary including cut point works.The works also includes re erection of dismantled LT line and associated materials whereever necessary.
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling.
Reconductoring of LT Line with Bare ACSR conductor OH ( Rabbit )
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Dismantling (without damage) LT Single /three phase OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.The work also includes dismantling of service connections, branch circuits, street lights etc
Single phase Two wire
Insertion of one LT PSC pole in existing Single /three phase OH line including digging & back filling pit in all classes of soil, fitting cross arm, insulator, binding etc. drawing sufficient length of GI earth leads to the ground for earthing.
Renewal of existing damaged/old LT PSC/RCC/Teak wood (Single phase/ three phase line) pole with new PSC pole in place including excavation of pole pit, erection of new pole, backfilling pit and refitting of all items, including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm , insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Erection of LT complete stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Renewal of existing damaged/old LT stay with complete stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, conveyance the dismantlled items to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Fitting and providing one Strut using LT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Stringing ACSR conductor, shackling, fitting cross arms, insulators and binding helically formed ties suitable for ACSR Rabbit, giving jumper connections, providing LT line spacers etc. The work also includes 1. Touching clearance where ever necessary 2. Reconnection of service connections branch circuits , street lights and re erection of 11 kV line where ever necessary 3. Staightening of poles etc.
Single phase Two wire
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling.
Fitting one Section fuse with base frame on LT line with dropping cables, crimping sockets, connecting with bolt & nut etc.
New LT line using ABC - 3 x 95 + 1 x 70 + 1 x 16 sqmm
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Erecting one LT PSC Pole in position including digging & back filling pit in all classes of soil.
Fitting and erecting one HT PSC Single Pole in position, fitting cross arm if needed, digging and back filling pit in all classes of soil (as per standards), drawing sufficient length of GI earthing leads to the ground for earthing etc.(excluding provision of earthing)
Erection of complete stay set LT along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Fitting and providing one Strut using LT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil , including the cost of Strut clamp.
Providing Fly stay for LT pole using LT PSC pole including digging and back filling pit in all classes of soil including Erection of complete stay set ,with GI stay wire ( 7/3.15 mm dia), binding of stay wire,providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings
Drawing, Testing and commissioning of LT AB cable. Stringing of 1.1 kV Aerial bunched cable 3 x 95 + 1 x 70 + 1 x 16 Sqmm with insulated Messenger through existing/renewed poles, erection of tension clamp for dead ends, suspension clamps , installation of IPCs of various types and satellite connectors where ever necessary. The work also includes the following 1. Touching clearance where ever necessary. 2.UV plastic tie for binding conductors ( Including cost of plastic tie) 3. Providing end caps ( Including cost of end caps) 4. Installation of pre insulated mid span joints of sizes 16 sqmm, 70 Sqmm, 95 sqmm as per field requirement( Including cost of pre insulated mid span joints). 5. Pole numbering as per standards . 6. Installation of pre insulated bi metallic lugs at transformer points & other fuse points.
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in all classes of soil & backfilling.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Fitting of one No. pole top service connection box of standard size - up to 4 way (3 phase connection -4 Nos or 1 Ph connection - 12 Nos ) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height including giving connections
Conversion of LT ACSR OH 1 Ph 3 W to 3 ph 5W & Conversion of LT ACSR OH 1 Ph 2 W to 3 ph 4W
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Conversion of LT single phase 2 wire line to LT three phase 4 wire line including dismantling the existing 2 conductors and its accessories, service connections, branch circuits, jumper connections etc, stringing 4Wire ACSR Rabbit conductor (Helically formed ties shall be used for binding conductors with Pin insulators), providing new jumper connections, line spacers , reconnecting dismantlled service connections, branch circuits etc including conveyance of materials.
Conversion of LT single phase 3 wire line to LT three phase 5 wire line including dismantling the existing 3 conductors and its accessories, service connections, branch circuits, jumper connections etc, stringing 5Wire ACSR Rabbit conductor (Helically formed ties shall be used for binding conductors with Pin insulators), providing new jumper connections, line spacers , reconnecting dismantlled service connections, branch circuits etc including conveyance of materials.
Insertion of one LT PSC pole in existing three phase OH line including digging & back filling pit in all classes of soil, fitting cross arm, insulator, binding etc. drawing sufficient length of GI earth leads to the ground for earthing.
Renewal of existing damaged/old LT PSC/RCC/teak wood (Single phase/ three phase line) pole with new PSC pole in place including excavation of pole pit, erection of new pole, backfilling pit and refitting of all items, including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm , insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Renewal of existing damaged/old 11kV PSC/RCC/ Teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items , drawing sufficient length of GI earth leads to the ground for earthing. etc complete including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Erection of LT complete stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 1 No) and 0.2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Renewal of existing damaged/old LT stay with complete stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 1 No) and 0.2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, conveyance the dismantlled items to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of existing damaged/old 11kV Stay with complete stay set along with excavation of stay pit in classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Providing Strut using LT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in all classes soil & backfilling including crimping the same with GI wire in the pole using ferruls etc.
Fitting one Section fuse with base frame on LT line with dropping cables, crimping sockets, connecting with bolt & nut etc.
Conversion of LT Sph line to 3 Ph lines with ABC using 3X70+1X50+1X16 sqmm
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Dismantling (without damage) 11 kV/LT Single /three phase OH line conductor by dismantling cross arms, insulators, spacers, jumper connections etc and stacking the conductors in rolls properly including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.The work also includes dismantling of branch circuit, service connection, street light etc
Single phase Two wire
Single phase Three wire
Insertion of one LT PSC pole in existing three phase OH line including digging & back filling pit in all classes of soil, binding etc. drawing sufficient length of GI earth leads to the ground for earthing.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm , insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Insertion of one HT 'A' type pole in existing OH line including digging & backfilling pit in all classes of soil , fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing).
Providing concrete muffing for A pole of size 0.45x0.45x1.5m (0.5 m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5 sides
Rnewal of existing damaged/old LT PSC/RCC/teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items etc . Conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL is also form part of the work.
Renewal of existing damaged/old 11kV PSC/RCC/ Teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items , drawing sufficient length of GI earth leads to the ground for earthing. etc complete including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Renewal of existing damaged/old LT stay with complete stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Erection of complete LT stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 1 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of existing damaged/old 11kV Stay with complete stay set along with excavation of stay pit in classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Providing Strut using LT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Drawing, Testing and commissioning of LT AB cable. Stringing of 1.1 kV Aerial bunched cable with insulated Messenger through existing/renewed poles, erection of tension clamp for dead ends, suspension clamps , installation of IPCs of various types and satellite connectors where ever necessary. The work also includes the following 1. Touching clearance where ever necessary . 2. UV plastic tie for binding the conductors ( Including cost of plastic tie) 3. Providing end caps ( Including cost of end caps) 4. Installation of pre insulated mid span joints of sizes 16 sqmm, 35Sq.mm, 50 Sqmm,70 sqmm & 95 sqmm as per field requirement( Including cost of pre insulated mid span joints). 5. Reconnection of service connection, branch circuit lines, street light & re erection of dismantled 11kV lines where ever necessary 6. Straightening of poles where ever necessary 7. Installation of pre insulated bi metallic lugs at transformer points & other fuse points etc.
3 x 70 + 1 x 50+1x 16 sqmm with insulated Messenger
Fitting of one No. pole top service connection box of standard size - up to 4 way (3 phase connection -4 Nos or 1 Ph connection - 12 Nos ) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height including giving connections
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in all classes soil & backfilling.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
RING MAIN UNIT
RMUs : Installation & Commissioning of SCADA compatible Extensible RMUs of various configurations - Cost of construction of foundation as per approved drawings, base plates, fixing anchor bolts, handling, erection, alignment and allied works for the installation of Data Aquisition compatible Extensible type Ring Main Units with terminal protector boots & extension modules, actuators for remote operations, communicable FPIs, CTs, PTs & relay contacts for SCADA, giving power & control wiring and connections, providing terminal protector, interconnecting RMU bus bar and control cables, providing metered LT supply from nearest LT pole, providing earth leads, cable mounting & terminations, giving connections after ascertain proper phase sequence, providing location name & warning boards and RDSS signboards, burying cables & refilling, conducting all pre commissioning tests as required, complete.
11kV 630 A SCADA compatible Extensible RMU CCC -Load break switchs 3 nos
11kV 630 A SCADA compatible Extensible RMU CTC - Load break switch 2 nos & VCB 1 No
11kV 630 A SCADA compatible Extensible RMU CC - Load break switchs 2 nos
11kV 630 A SCADA compatible Extensible RMU Add on T - VCB 1 nos
11kV 630 A SCADA compatible Extensible RMU Add on C-Load break switchs 1 nos
11kV 630 A SCADA compatible Extensible RMU CCCTT - Load break switchs 3 nos & VCB 2 nos
Mounting and connecting HT XLPE UG cable ends of all sizes upto and including 3x300 sq mm with special type cable clamps, bolts, nuts, terminal protectors etc.including cost of extra materials if needed and giving necessary jumper connections.
Doing one cable end termination on HT XLPE UG cables of sizes beyond 3x185 sqmm and upto and including 3x300 sq mm using the cable jointing kit after making fencing,caution board and all other safety measures including charges for cable jointer etc. complete as per the direction of the departmental officers.
Providing one Earth as per spec and approved drawing , using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing RMU fencing using steel work using 40 mm Dia GI pipes for verticals & outer frame of gate, providing gate with locking arrangements, with two horizondal bracings using 40 x 6 mm MS flat & grills with MS rods 8 mm Dia @ 10cm c/c for verticals for the gate, providing danger board & name board, fixing in position, concreting the base with 1:2:4 CC, applying one coat of zinc chromate primer and two coats of aluminium paint for fencing post and gate frame, providing fencing with 4 mm GI chain link fixed to GI post, as per detailed specifications including all charges
Cleaning and levelling of transformer yard/RMU, spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Doing one cable end termination on HT XLPE UG cables of size 3x150 sqmm using the cable jointing kit after making fencing,caution board and all other safety measures including charges for cable jointer etc. complete as per the direction of the departmental officers.
Doing one cable end termination on HT XLPE Ariel Bunched cables of size 3x120 sqmm using the cable jointing kit after making fencing,caution board and all other safety measures including charges for cable jointer etc. complete as per the direction of the departmental officers.
Laying 3X150 sqmm XLPE UG cable including convinces and transportation
Uplifting of RMU in existing location after dismantling of RMU, demolishing existing RMU foundation, disconnecting all connections including earth leads etc, and construction of new RMU foundation by providing all required materials and re erecting the RMU in the new foundation in all respects. This work includes construction of uplifted foundation using RCC 1:1.5:3 and base plates, anchor bolts and giving all connections with all required materials . Work also includes loading and unloading of all materials including RMU.
Reconductoring of LT Line with XLPE insulated covered conductor equivalent to ACSR 50sqmm Rabbit conductor
Survey of line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Dismantling (without damage) 11kV/ LT- Single /three phase OH line conductor by dismantling cross arms, insulators , other acceessories and service connection, branch circuit, jumper connections,spacers etc and stacking the conductors in rolls properly including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Single phase Two wire
Single phase Three wire
Three phase Four wire
Three phase Five wire
Insertion of one LT PSC pole in existing Single/three phase OH line including digging & back filling pit in all classes of soil, fitting cross arm, insulator, binding etc. drawing sufficient length of GI earth leads to the ground for earthing.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm , insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Renewal of existing damaged/old LT PSC/RCC/teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items etc . Conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL is also form part of the work.
Renewal of existing damaged/old 11kV PSC/RCC/ Teak wood Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items , drawing sufficient length of GI earth leads to the ground for earthing. etc complete including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Erection of complete stay ( LT) set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Renewal of existing damaged/old LT stay with complete stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator (1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Renewal of existing damaged/old 11kV Stay with complete stay set along with excavation of stay pit in classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one Strut using LT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Providing Fly stay for LT pole using LT PSC pole, drawing sufficient length of GI earth leads to the ground for earthing including excavation of stay pit in all classes of soil and back filling, erection of complete stay set along with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 No) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc.
Stringing of 1.1 kV XLPE insulated covered conductor equivalent to ACSR Rabbit 50 Sqmm through existing/renewed poles,fitting insulators where ever necessry,binding conductors to pin insulators using helical UV plastic tie suitable for any neck dia , erection of tension clamp for dead ends, installation of IPCs of various types and satellite connectors where ever necessary. The work also includes the following 1. Touching clearance where ever necessary. 2. UV plastic tie for binding the conductors 3. Providing end caps ( Including cost of end caps) 4. Installation of pre insulated mid span joints suitable for XLPE insulated covered conductor equivalent to ACSR Rabbit 50 Sqmm as per field requirement( Including cost of pre insulated mid span joints). 5. Reconnection of service connection, branch circuit lines, street light & re erection of dismantled 11kV lines where ever necessary 6. Installation of pre insulated bi metallic lugs at transformer points & other fuse points. 7.Straightening of poles where ever necessary etc.
1 Ph 2 wire line
1 Ph 3 wire
3 Ph 4 wire line
3 Ph 5 wire line
Fitting of one No. pole top service connection box of standard size - up to 4 way (3 phase connection -4 Nos or 1 Ph connection - 12 Nos ) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height including giving connections
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling.
Conversion of LT line using XLPE insulated covered conductor equivalent to ACSR 50sqmm Rabbit conductor
Survey one km line using GPS, route alignment and , preparation of survey report and uploading in the web portal after approval of project manager.
Insertion of one LT PSC pole in existing three phase OH line including digging & back filling pit in all classes of soil, fitting cross arm, insulator, binding etc. drawing sufficient length of GI earth leads to the ground for earthing.
Renewal of existing damaged/old LT PSC/RCC Pole with new PSC pole in place including excavation, erection of new pole, backfilling pit and refitting of all items etc . Conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL is also form part of the work.
Insertion of one HT PSC pole in existing OH line including digging & backfilling pit in all classes of soil, fitting cross arm , insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing.
Dismantling (without damage) LT single phase 2 wire OH line conductor by dismantling cross arms, insulators , other acceessories and service connection, branch circuit, jumper connections, spacers etc and stacking the conductors in rolls properly including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Erection of complete stay set LT along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 1 No ) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings and backfilling etc.
Renewal of existing damaged/old LT stay with complete stay set along with excavation of stay pit in all classes of soil with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 1 no) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings & backfilling of pit, dismantling, refitting of all items in place including the conveyance of the taken back materials to KSEBL store and stacking the same with proper documentation as directed by KSEBL.
Fitting and providing one Strut using LT PSC pole using proper size of strut clamp ( GI) including digging and back filling pit in all classes of soil. The Cost includes cost of Strut clamp also.
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, providing guy stay insulator ( 2 Nos) and .2 cum concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Stringing of 1.1 kV XLPE insulated covered conductor equivalent to ACSR Rabbit 50 Sqmm through existing/renewed poles,fitting insulators where ever necessry,binding conductors to pin insulators using helical UV plastic tie suitable for any neck dia , erection of tension clamp for dead ends, installation of IPCs of various types and satellite connectors where ever necessary. The work also includes the following 1. Touching clearance where ever necessary. 2. UV plastic tie for binding the conductors 3. Providing end caps ( Including cost of end caps) 4. Installation of pre insulated mid span joints suitable for 50 Sqmm as per field requirement( Including cost of pre insulated mid span joints). 5. Reconnection of service connection, branch circuit lines & street light and re erection of 11 kV line where ever necessary 6. Installation of pre insulated bi metallic lugs at transformer points & other fuse points 7. Staightening of poles etc.
3 Ph 4 wire line
Fitting of one No. pole top service connection box of standard size - up to 4 way (3 phase connection -4 Nos or 1 Ph connection - 12 Nos ) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height including giving connections
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling, uisng IPC
LOAD BREAK SWITCH
Fitting and erecting one HT Double Pole Structure using PSC pole in position including fitting channel cross arms, digging and back filling pit in all classes of soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing).
Fitting and providing one HT Stay for 11kV pole - excavation of stay pit in all classes of soil and back filling including erection of complete stay set along with with GI stay wire ( 7/3.15 mm dia), binding of stay wire, by providing guy stay insulator ( 2 Nos) and .2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6) as per technical specification, approved drawings etc. .
Additional rate for providing one disc set on any type of HT pole for making cut point
Fitting one Additional 2.4m/ 3m channel cross arm in existing 11kv DP
Erection of Station Class Lightning Arrestor 9KV, 10KA
Drawing HT XLPE UG cable of sizes beyond 3x185 sq mm and upto and including 3x300 sq mm carefully taking through HDPE pipes of size 110mm at DP structure, with both ends to safeguard cable and mounting , including cost of extra materials if needed and giving necessary connections with the existing OH line using kiss joint to complete the work in all respect.
Mounting and connecting HT XLPE UG cable ends of all sizes upto and including 3x300 sq mm with special type cable clamps, bolts, nuts, terminal protectors etc.including cost of extra materials if needed and giving necessary jumper connections.
Doing one cable end termination on HT XLPE UG cables of sizes beyond 3x185 sqmm and upto and including 3x300 sq mm using the cable jointing kit after baricading, caution board and all other safety measures including charges for cable jointer etc. complete as per the direction of the departmental officers.
Installation of SCADA Compatible CT RMU 11 kV 630 Amps 21 kA for 3 seconds with primary protection CT rating of 100-200/5 Amps (or) 150-300/5 Amps providing OH line protection in T-Limb of the RMU.
Providing one Earth using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing RMU fencing using steel work using 40 mm Dia GI pipes for verticals & outer frame of gate, providing gate with locking arrangements, with two horizondal bracings using 40 x 6 mm MS flat & grills with MS rods 8 mm Dia @ 10cm c/c for verticals for the gate, providing danger board & name board, fixing in position, concreting the base with 1:2:4 CC, applying one coat of zinc chromate primer and two coats of aluminium paint for fencing post and gate frame, providing fencing with 4 mm GI chain link fixed to GI post, as per detailed specifications including all charges
Cleaning and levelling of transformer yard/RMU, spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Description of Work / Item(s)
Materials( Total Ex-work price of Materials + Total Transportation cost ) excluding GST.
Installation / Erection Charges (Excluding GST)
TOTAL AMOUNT [1+2] (Excluding GST)
Discount offerred by Bidder(If any)
BOQ 3 : GRAND TOTAL (3-4)
Grand Total including GST (5+ GST Amount of BOQ1+GST Amount of BOQ2 )
RAMALINGAM CONSTRUCTION COMPANY PVT LTD
Lumino Industries Limited
Vindhya Telelinks Limited
RAMALINGAM CONSTRUCTION COMPANY PVT LTD
RAMALINGAM CONSTRUCTION COMPANY PVT LTD
Lumino Industries Limited
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid