1 Excavation for foundation upto 1.5 m depth including sorting out and stacking of 2430.00 Cumt 153.41
useful materials and disposing off the excavated stuff upto 50 Meter lead. (B) Dense or
2 Excavation for foundation upto 1.5 m depth including sorting out and stacking of 1242.00 Cumt 267.87
useful materials and disposing off the excavated stuff upto 50 Meter lead. (D) Soft rock
not requiring Blasting
3 Filling in foundation and plinth with sand in layers of 20 cm. Thickness including 316.00 Cumt 471.69
watering ramming and consolidating etc. comp.
4 Filling available excavated Earth (Excluding Rock) in trench plinth side of foundation . 1421.00 Cumt 133.65
in layer not excluding 20 cm in depth consolidation each deposited layer by ramming
and watering etc. complete
thickness including ramming watering and consolidating etc. complete
6 Anti Termite System 1535.00 Sqmt 134.33
P/L of Permenent piping technology Anti Termite treatment before flooring work by
installing LLDP (Low linear density Polyethylene) tube of 8 mm O.D.& 6.4 mm I.D.With
in Built Pressure Compenstaion chif every 30 cm interval in the tube, having working
pressure of 2 kg/cm 2 and realese rate of 1.9 ltr/Hour fixed by P-Clip and nails . The
LLDP pipe shall be installed at the entire periphery of the building and at internal
network of building depth of 20 to 200 mm under floor every 2 to 3 mtr.c/c distance
(adjustble as per building layout ) & Ends of loop pass through a PVC Elbow of
minmum 32 mm ID at junction box of wall and floor level, entring into a steel
reinforcmed grooved flexible pipe mini.22 mm LD leading into junction box and
during injecting chemicls for termite control tretment. The anti-termite chemical
Lmidcloprid 30.5% SC Mix as per IS 6313(part-III) shall be injected by the pressure
pump diluted with water @ 10.5 ml/5ltr of water at the rate of 2 kg/sq,cm.@ 5 ltr
/Smt .the contractor shall submit approved line plan for piping system and junction
boxes dully approved By Engineer -in-charge with bond of 5 Years warnty .
7 Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- machine 102.40 Cumt 3080.90
cut stone aggregates 40 mm nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth
8 Providing and laying controlled cement concrete M150 for curing complete including 457.00 Cumt 4084.73
cost of formwork but excluding the cost of reinforcement for reinforced concrete work
in (A) Foundations, footings,Base of columns, Plinth Slab and Mass concrete.
9 Providing and laying controlled cement concrete M250 and curing complete including 699.00 Cumt 4638.93
the cost of formwork and excluding reinforcement for reinforced concrete work in (A)
Foundations, footings and Mass concrete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
10 Providing and laying controlled cement concrete M250 and curing complete including 63.00 Cumt 7351.11
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts Column Up to Plinth Level
11 Providing and laying controlled cement concrete M200 and curing complete including 140.00 Cumt 7305.83
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts Floor Two Level
12 Providing and laying controlled cement concrete M200 and curing complete including 50.00 Cumt 7345.62
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts Second Floor
13 Providing and laying controlled cement concrete M200 and curing complete including 16.00 Cumt 7386.88
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts 3rd Floor
14 Providing and laying controlled cement concrete M250 and curing complete including 415.00 Cumt 6236.84
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Ground & Plinth BEAMS
15 Providing and laying controlled cement concrete M150 and curing complete including 245.00 Cumt 5318.56
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
Plinth Slabs
16 Providing and laying controlled cement concrete M200 and curing complete including 371.00 Cumt 6199.86
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
Floor Two Level Beams
17 Providing and laying controlled cement concrete M200 and curing complete including 185.00 Cumt 6241.12
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
Second Floor Beams
18 Providing and laying controlled cement concrete M200 and curing complete including 11.00 Cumt 6282.38
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
3rd Floor Beams
19 Providing and laying controlled cement concrete M200 and curing etc. complete 16.00 Cumt 6499.46
including the cost of form work and reinforcement for reinforced concrete work in (C)
Chhajja for Floor Two Level
20 Providing and laying controlled cement concrete M200 and curing etc. complete 7.00 Cumt 6540.72
including the cost of form work and reinforcement for reinforced concrete work in (C)
Chhajja for Second Floor
21 Providing and laying controlled cement concrete M200 and curing etc. complete 0.22 Cumt 6581.97
including the cost of form work and reinforcement for reinforced concrete work in (C)
Chhajja for 3rd Floor
22 Providing and laying controlled cement concrete M200 and curing etc. complete 18.00 Cumt 7498.49
including the cost of form work and reinforcement for reinforced concrete work in (C)
Lintal for Floor Two Level
23 Providing and laying controlled cement concrete M200 and curing etc. complete 8.00 Cumt 7539.75
including the cost of form work and reinforcement for reinforced concrete work in (C)
Lintal for Second Floor
Item Rate In
Description of Item Quantity Unit Amount
No figures
24 Providing and laying controlled cement concrete M200 and curing etc. complete 0.10 Cumt 7580.97
including the cost of form work and reinforcement for reinforced concrete work in (C)
Lintal for 3rd Floor
25 Providing and laying controlled cement concrete M200 and curing complete including 405.00 Cumt 6704.65
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
Floor Two Level Slab
26 Providing and laying controlled cement concrete M200 and curing complete including 193.00 Cumt 6745.91
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
Second Floor Slab
27 Providing and laying controlled cement concrete M200 and curing complete including 11.00 Cumt 6787.17
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
3rd Floor Slab
28 Providing and laying controlled cement concrete M200 and curing etc. complete 14.00 Cumt 8367.39
including the cost of form work and excluding the cost of reinforcement etc. complete
in (E) Stair case for Ground Floor to Second floor
29 Providing and laying controlled cement concrete M200 and curing etc. complete 6.00 Cumt 8408.65
including the cost of form work and excluding the cost of reinforcement etc. complete
in (E) Stair case for Second floor to 3rd F
30 Providing and laying controlled cement concrete M200 and curing etc. complete 43.00 Cumt 10414.84
including the cost of form work and excluding the cost of reinforcement etc. complete
in RCC Vertical and Horizontal wall for Floor Two Level
31 Providing and laying controlled cement concrete M200 and curing etc. complete 9.00 Cumt 10456.10
including the cost of form work and excluding the cost of reinforcement etc. complete
in RCC Vertical and Horizontal wall for Second Floor
32 Providing and laying controlled cement concrete M200 and curing etc. complete 5.00 Cumt 10497.36
including the cost of form work and excluding the cost of reinforcement etc. complete
in RCC Vertical and Horizontal wall for 3rd Floor
33 Providing and laying controlled cement concrete M200 for RCC work and curing 20.50 Cumt 6437.24
complete including the cost of form work but excluding the cost of reinforced concrete
work in Coping on Floor Two Level
34 Providing and laying controlled cement concrete M200 for RCC work and curing 0.90 Cumt 6478.49
complete including the cost of form work but excluding the cost of reinforced concrete
work in Coping on Second Floor
35 Providing and laying controlled cement concrete M200 for RCC work and curing 9.30 Cumt 6519.75
complete including the cost of form work but excluding the cost of reinforced concrete
work in Coping on 3rd Floor
36 Providing IS Mark TMT FE 500D bar reinforcement for RCC work including bending & 372116.94 Kg 77.67
placing in position complete up to All floor Level
Item Rate In
Description of Item Quantity Unit Amount
No figures
37 Providing and fixing 90 cm Height Stainless Steel Railing made from anticorrocive 304 31.00 Rmt 3626.51
grade S S pipe of 50 mm dia (16 Gauge) as hand rail with S S 304 grade Baluster of
mm dia Box pipe (16 Gauge) as a vertical support fixed in RCC slab at 1.2m c/c
including three horizontal S S pipes of 25 mm dia (16 Gauge) at eqal distance fixed by
18.75 mm dia (16 Gauge) S S pipe with baluster including accessories as per detailed
drawing as directed etc. complete.
38 Providing, laying and fixing 30 cm Height SS Railing made from anticorrocive up of 144.00 Rmt 1571.96
RCC Perapet Wall on fixing Hand Railing 50 mm dia S.S. 304 grade (16 Gauge) SS
Round Hollow pipe horizontal 1 Nos and 35mm dia vertical connection pipe 3 No with
all material , laboure charges and accessories as per requirement as directed by
Engineer-in-charge etc. complete.
39 Brick work using common burnt clay building bricks having crushing strength not less 146.00 Cumt 4121.55
than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine
sand) (B) Conventional below plinth
40 Brick work using common burnt clay building bricks having crushing strength not less 556.00 Cumt 4403.40
than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine
sand) (B) Conventional Floor Two Level
41 Brick work using common burnt clay building bricks having crushing strength not less 173.00 Cumt 4444.90
than 35 kg./Sq.Cm. in super structure in Cement Mortar 1:5. (1- Cement : 5 -fine sand)
(B) Conventional Second FLoor
42 Brick work using common burnt clay building bricks having crushing strength not less 88.00 Cumt 4486.40
than 35 kg./Sq.Cm. in super structure in Cement Mortar 1:5. (1- Cement : 5 -fine sand)
(B) Conventional 3rd FLoor
43 Half Brick masonry in common brunt clay building bricks having crushing strength not 307.00 Sqmt 669.34
less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in
foundation and plinth (B) Conventional in super structure. for Floor Two Level
44 Half Brick masonry in common brunt clay building bricks having crushing strength not 144.75 Sqmt 675.49
less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in
foundation and plinth (B) Conventional in super structure. For Second floor
45 Providing and fixing 150 mm wide, approved quality chicken wire mesh at junction of 1041.00 Sqmt 295.12
brick work and RCC work or two dissimilar surfaces, at all heights fixed by nails, rowal
plugs or tag by cement mortar 1:3 before applying the plaster, including curing,
scaffolding all complete as directed.
46 Providing 20 mm thick double coat mala cement plaster on interior brick / concrete 4361.00 Sqmt 285.35
work for plastering comprising of base coat of 12 mm thick cement plaster in cement
mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of
cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including
scaffolding curing, 10x10 mm grooves etc. complete. For Floor two Level
Item Rate In
Description of Item Quantity Unit Amount
No figures
47 Providing 20 mm thick double coat mala cement plaster on interior brick / concrete 2048.00 Sqmt 312.74
work for plastering comprising of base coat of 12 mm thick cement plaster in cement
mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of
cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including
scaffolding curing, 10x10 mm grooves etc. complete. For Second Floor
48 Providing 20 mm thick double coat mala cement plaster on interior brick / concrete 278.00 Sqmt 340.13
work for plastering comprising of base coat of 12 mm thick cement plaster in cement
mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of
cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including
scaffolding curing, 10x10 mm grooves etc. complete. For 3rd Floor
49 Providing 10 mm. Thick cement plaster in single coat for plastering on ceiling and 2493.00 Sqmt 156.74
soffits of stairs and finished even and smooth in : (I) Cement mortar 1:4 (1 cement :
sand) including Mala troveled finish etc. complete. Floor Two Level
50 Providing 10 mm. Thick cement plaster in single coat for plastering on ceiling and 1208.00 Sqmt 179.19
soffits of stairs and finished even and smooth in : (I) Cement mortar 1:4 (1 cement :
sand) including Mala troveled finish etc. complete. Second Floor
51 Providing 10 mm. Thick cement plaster in single coat for plastering on ceiling and 74.00 Sqmt 203.17
soffits of stairs and finished even and smooth in : (I) Cement mortar 1:4 (1 cement :
sand) including Mala troveled finish etc. complete. 3rd Floor
52 20 mm thick Sand faced cement plaster with 18x8 mm grooves as suggested by this 6494.00 Sqmt 389.46
office consisting of 12 mm thick backing coat of C.M. 1:3 ( 1 cement : 3 coarse sand )
and 8 mm thick finishing coat of C.M. 1:1 ( 1 cement : 1 coarse sand) for all heights as
directed etc. complete. and as per pattern sample aprroved by the architect or
directed engineer in-charge
53 Providing throating or plaster drip and moulding to R.C.C. Chhajja. 325.00 Rmt 43.22
Item Rate In
Description of Item Quantity Unit Amount
No figures
54 Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular 449.00 Sqmt 1674.15
edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light
weight calcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per
B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m
KC.for the best thermal Insulation. The Light weight calcium Silicate tile shall be of approved
texture Fine fissured/ Spintone/ Cosmos having NRC value of 0.5 & Globe having NRC value of
0.75 NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended
inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per
sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required
length and size of 24 X 38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to
centre, and cross ‘T’ of size 24 X 28mm made out of 0.33mm (Minimum) sheet spaced
1200mm along spaced between main 'T' at 600mm centre to centre to form agrid of
1200x600mm and size 24x48mm made of 0.30mm thick (Minimum) sheet to be interlocked
at middle of the 1200x600mm panel to form grid of size 600x600mm resting on periphery
walls/partitions on a perimeter wall angle pre-coated steel of size (24x24x3000mm made of
0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with
25mm long dry wall screws @ 230mm interval and laying 15mm thick densified edges light
weight calcium silicate ceiling tiles of approved texture (Fine fissured/Cosmos/Spintone) in
the grid including cutting/making opening for services like diffusers, grills, light fittings,
fixtures, smoke dtectors etc., wheneveer required, Main 'T' runners to be suspended from
ceiling using G.I. slotted cleats of size 25x35x1.6mm fixed to ceiling with 12.5mm dia and
50mm long dash fasterners, 4mm G.I. adjustable rods with galvanized steel evel clips of size
85x30x0.8mm, spaced at 1200mm center to centre long main 'T' bottom exposed with 24mm
of all T-sections and also provide additional frame work and suspended G.I. support as
required height shall be pre-painted with polyester baked paint, for all heights, as per
specifications, drawings and as directed by engineer-in-charge. Note:- Only calcium silicate
false ceiling area will be measured from wall to wall. No deducation shall be made for exposed
frames/opening (cut outs) having area less than 0.30sqm. The calcium silicate ceiling tiles
shall fissured/Spintone/Cosmos and 0.75 NRC for Globe, light reflection 85% non-
combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal
conductivity. 0.043 w/m KC for the best thermal Insulation.
55 Applying two coats of Acrylic lapy (putty) & two coats of primer of approved brand 10636.00 Sqmt 40.59
and manufacture on new wall surface to give an even shade including thoroughly
brushing the surface free from mortar dropping and other foreign matter and sand
papered smooth.
56 Wall painting (two coats) with plastic emulsion paint of approved brand and 6865.00 Sqmt 81.38
manufacture on undecorated wall surface to give an even shade including throughly
brushing the surface free from mortar droppings and other foreign matter and sand
papered smooth.
57 Painting (two coats) with plastic emulsion paint of approved brand and manufacture 3771.00 Sqmt 86.92
on undecorated ceiling surface to give an even shade including throughly brushing the
surface free from mortar droppings and other foreign matter and sand papered
58 Wall Painting (Two coats) with weather proof 100% acraylic emulsion paint of 11528.00 Sqmt 117.40
approved brand and manufacture and of required shade on exterior wall surface to
give an even shade over and including primery coat with Alkaly resistance primer of
approved brand after thoroughly brushing surface to remove all dust and remains of
loose powdered material etc. copm. for all height
59 Providing And filling with good quality cinder (steam coal) as directed by engineer in 76.00 Cumt 517.73
charge in sunks in layers of 15 cm thick,including watering,placing ,ramming well etc
as directed, for all floor.
Item Rate In
Description of Item Quantity Unit Amount
No figures
60 Providing Water proofing Treatment on Sunk Slab including cement concrete flooring 459.00 Sqmt 376.63
1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm nominal size) laid in
one layer and finished with a floating coat of neat cement average 50mm thick to
Prepare slope including water proofing chemical etc. Complete for Sunk Slab All Floor.
61 Providing and laying water proofing treatment with china mosaic tiles flooring over 1347.00 Sqmt 1153.42
avg 50 mm C.C. 1:2:4 bedding for maintaining slope for plain and curve surface &
mm to 20 mm of broken piece not more than 2.5CM of ceramic / glazed tiles ( one for
more colour as directed ) to be laid over cement mortar bedding of C M 1:3 (1 cement :
3 sand ) contain water proofing materials per bag of cement useas specified by
manufactured and slops to be tempered to bring mortar up to surface with using white
cement and colour pigment including rounding of junctions and extending them up to
15 cm along the wall and curing with bends any patens or design as per drawing and
cleaning by using oxalic acid etc. complete.
62 Providing Plinth Protection to Building including excavation in ordinary soil and 324.00 Sqmt 1436.22
laying cement concrete 1:3:6 using stone aggregates of 40mm nominal size in
foundation layer 100 mm thick below pre-cast Rubber Dye inter locking concrete
block 60mm thick with grade of concrete M200 pneumatic compressed by
mechanically pressed and as per approved design including 75mm Sand layer for
levelling and filling the joint with sand in proper line and level etc. complete, Including
Providing and fixing pre-cast concrete kerb stone of grey cement based concrete block
30cm length, 30cm height and 15cm thick of M250 grade concrete as per approved
design and including excavation for fixing in proper line and level, filling the joint with
C:M 1:3 (1cement:3 fine sand) etc. complete.
63 Providing and fixing window having extruded aluminum Colour anodized section 244.00 Sqmt 1759.97
frame main outer size 63.50 x 38.10 x 1.95 mm,@ Wt 1.094 Kg / Rmt, horizontal Two
track member size 61.85 mm x 31.75 mm x 1.20mm @ wt.of 0.695 Kg/mt, vertical
member of size 61.85 mm x 31.75mm x 1.30 mm @ wt.of 0.659 Kg/mt with sliding
shutters of horizontal member size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt,
vertical member of size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt, @ Wt.
Kg/mt with 5 mm thick transparent bronze colour tinted float glass with powder
coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to
frame (V1) with same glass and frame as (W1) window as details etc complete.
64 Providing and fixing window having extruded aluminum Colour anodized section 21.00 Sqmt 1768.31
frame main outer size 95mm x 24mm x 1.17mm @ wt.of 0.738 Kg/mt , horizontal
Three track member size 92mm x 31.75mm x 1.30mm,@ Wt.1.07 Kg/mt , vertical
member of size 92mm x 31.75mm x 1.50mm @ Wt. 1.06 Kg/mt with sliding shutters of
horizontal member size 40 mmx18mm x1.29mm @ wt.of 0.456 Kg/mt, vertical
member of size 40mm x 18mm x 1.29 mm @ wt.of 0.456Kg/mt/ with 5 mm thick
transparent bronze colour tinted float glass with powder coated aluminum fittings and
fixtures and transparent silicon sealant glass fixing to frame as per details etc. For
(W2) Window
Item Rate In
Description of Item Quantity Unit Amount
No figures
65 Providing & Fixing in position standard extruded approved colour anodised Aluminum 212.00 Sqmt 2724.07
Ventilation with outer frame 65 x 25 x 1.50 mm Stander Box Frame @ Wt
kg/Rmt with 5mm thick fixed ground glass and Mosquito net jali fixed to alluminium
strip blade fixed or adjestable ventilation including all required materials, fixtures,
fastenning, labours and equipments as per detailed drawing as directed. For
Ventilators
66 Providing and fixing Decorative Entrance Gate made out of cast iron and various mild 806.40 Kg 167.16
steel tabular section combination , the Ornamental entrance gate should be fixed at
column including pattern and die making , cutting , welding , grinding, fabrication
fixing in position at column with necessary pedestal, bearing block and other locking
arrangement. The entrance gate should be painted with two coats of priming coat of
paint, and two coat of oil paint etc complete. As per detail design and directed by
engineer in charge.
67 Providing and fixing Single shuttered door having green marble frame with all open 117.00 Sqmt 3477.43
edges machine cut & machine polished, fixed by zinc coated hinges with double
shutter of factory made & stamped I.S 12823 grade one, type one 35 mm thick solid
core, melamine faced, three layered resin, flushed door , having decorative lamination
on both sides & 12 mm thick teak wood beading fixed around the door, Durable Grip
shall be providing with both side 15cm long stainless steel handle and necessary
Locking system, S.S. fixtures & fastenings etc. directed by engineer in charge. Door
from "NOVAPAN" OR Equivalent company holding Licence for Minimum 5 years.
68 Providing and fixing FRP frame size 100 x 50 mm and 35 mm thick ( Fiber Glass with 76.00 Sqmt 2363.40
PUF Injection ) FRP depress panel Single or Double shutter having extra reinforcement
on sides & edges in Gel coat finish.The core of the both shutter & frame is to be filed up
with injected fire retradat grade polyurethene foam done in situ along with embeded
wooden pieces for stiffening & also taking hinges & fintures.The whole FRP frame &
single or double shutter is to be waterproof, weatherproof, termite proof & resistance
to mild acid/alkali. Rates are to be inclusive of S.S hinges with necessary screws &
alluminum fixtures & fastenings & fartener sleeve.Colour and Shade approved by
Engineer-In-Charge.
69 Providing and laying 60 x 60 cm Machine polished Machine cut Kota Stone slab 3623.00 Sqmt 1084.30
flooring over 20 mm (average)thick base of cement mortar 1:6 (1-cement 6-coarse
sand) or L.M 1:1.5 (1 Lime putty : 1.5 coarse sand laid over and jointed with grey
cement slurry mixed with pigment to match the shade of slab including rubbing and
polishing etc.complete (A) 30mm thick
70 Providing and laying 60 x 60 cm Machine polished Blue Kota Stone slab 30 mm thick 167.00 Sqmt 1103.87
in riser of steps,skirting dedo and pillars laid on 10 mm thick cement mortar 1:3 (1-
cement 3-coarse sand) and jointed with grey cement slurry mixed with pigment to
match the shade of slab including rubbing and polishing etc.complete (30 mm thick)
71 Providing and laying antiskid ceramic tiles 30 x 30 cm size 6 mm thick in flooring 484.00 Sqmt 929.39
treads of steps and landing laid on a bed of 12 mm thick cement mortar 1:3(1-
cement:3-coarse sand)finishing with flush pointing in white cement
Item Rate In
Description of Item Quantity Unit Amount
No figures
72 Providing and laying glazed tiles tiles size 30 x 45 cm 6 mm thick in skirting risers of 1065.00 Sqmt 1477.25
steps and dedo on 10 mm thick cement plaster 1:3 (1-cement:3coarse sand) and
jointed with colour cement slurry
73 Providing and laying machine cut free edge machine Double polished granite stone 218.00 Sqmt 2023.03
18mm thick finished treads and risers in with 1cm projecting, nozing rounded
moulding in tread laid over 12 mm (av.) thick bases of cement mortar 1:6 (1-cement :
6-coarse sand) jointed with grey or colour cement slurry including rubbing and
polishing incl. making Three No.s of grooves of size 3mm X 3mm along the length of
treads etc. complete
74 Providing and fixing polished 18 mm thick black granite with full round edge and 15.00 Sqmt 2651.25
double side polished of approved quality in between urinal and fixing with cement
slurry & adhesive including moulding of both exposed edges as directed by
engineering in charge etc. complete.
75 Providing and fixing mirror polished 18 mm thick Green Marble stone with full round 625.00 Sqmt 2011.92
edge and polished of approved quality in clading on sill and around the doors/
windows/ ventilation with 12 mm thick cement mortor CM (1:4) and fixing with
cement slurry & adhesive including moulding of exposed edges as directed by
engineering in charge etc. complete.
76 Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 1902.00 Sqmt 704.07
60mm thick with grade of concrete M300 pnumatic compressed / vibrated
mechanically and as per approved design Confirming to IS 15658 : 2006 including
mm Sand layer for levelling and filling the joint with sand in proper line and level as
per guidlines of IRC : SP 63-2018 etc. Complete
77 Providinfg and fixing Safty grills of required pattern for windows/ Door using 14303.00 Kg 112.11
necessary 16x16 mm M.S. Square bar, M.S flats and other structural steel at required
spacing including cutting, welding and fabriction etc. including one coat of primer of
approved quality and two coats of oil painting as per detail drawing etc complete.
78 Providing erecting and fixing Virgin Plastic Sintex Black Double Layer Water Storage 20000.00 Litre 9.09
Tank of required capacity each with all necessary fittings and connection etc. complete
on terrace.
79 Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe ( SCH- 40) 130.00 Rmt 195.67
for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed
on the wall with the help of clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
Item Rate In
Description of Item Quantity Unit Amount
No figures
80 Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) 150.00 Rmt 148.12
for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed
on the wall with the help of clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
81 Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) 250.00 Rmt 91.84
for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed
on the wall with the help of clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
82 Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- 40) 210.00 Rmt 72.65
for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed
on the wall with the help of clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
83 Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) 100.00 Rmt 834.38
conforming to IS 13592-1992 with one end plain and other end socketed with rubber
ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be
fixed on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x
mm heigh at every 2000 mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement including cost of all materials.
84 Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) 180.00 Rmt 857.65
conforming to IS 13592-1992 with one end plain and other end socketed with rubber
ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be
fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x
mm heigh at every 2000 mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement including cost of all materials.
Item Rate In
Description of Item Quantity Unit Amount
No figures
85 Providing, laying and jointing in true line and level 75 mm dia. UPVC SWRType B pipe 50.00 Rmt 293.91
conforming to IS 13592-1992 with one end plain and other end socketed with
rubbering and fitting conforming to ISI 14735-1999 of approved make for drainage
system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall
be fixed on wall using of PVC clamp at every 2000 mm c/c or shall be conceled in
walss as directed including necessary fittings such as bends, shoes etc. including
testing of pipes and joints and jointed with adhesive solvent cement including cost of
all materials.
86 Providing and fixing in PVC SWR cowel went 75mm dia to pipes.(B) 75mm dia. 6.00 No 16.16
87 Providing and fixing in PVC SWR cowel went 110mm dia to pipes.(B) 110mm dia. 12.00 No 29.29
88 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with 174.00 No 585.37
jali of the following nominal diameter of self cleansing design with C.I scread down or
hinged grating including the cost of cutting and making good the walls.
89 Providing and fixing wash down water closet (European type W C pan) with integral P 36.00 No 3035.05
and S trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement
five sand) including providing and fixing plastic seat cover for wash down WC with CP
brass hinges and rubber buffers back plastic seat and including providing and fixing
PVC flushing tank with a pair of C I or MS bracket with complete fitting such as lead
valve siphon 15 mm dia brass ball valve with polythene float CP brass handle unions
and couplings for connection with inlet out let and over flow pipes 40 mm dia
porcelain enameled flush bend including cutting holes in walls and making good the
same connection the flush bend with cistern and closet vitreous china.
90 Providing and fixing stainless steel grab 22 cm x 60 cm for handicapped toilet 12.00 No 1492.78
91 Providing and fixing Angle cock with Wall flange crome finished brass (i) 15mm dia. 54.00 No 858.50
92 Providing and fixing ball cock of approved. quality as directed.(A) Copper Metal (ii) 4.00 No 189.84
93 Providing and fixing washbasin with single hole for pillar tap with C.I. or M.S. brackets 18.00 No 1649.22
painted white including Rubber plug, sutting holes and making good the same but
excluding fittings and also including rate of C.P. brass waste for washbasin or sink (A)
32mm dia. and M.I. fisher union for washbasin or sink. (A) 32mm dia.; (A) Vitreous
China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In white colour.
94 Providing and fixing 600mm x 450mm bevelled edge mirrror of superior glass 18.00 No 852.76
mounted on 6mm thick A.C. sheet or plywood sheet and fixing to wooden pluge with
C.P. brass screws and washers.
95 Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets fixed to 12.00 No 616.42
wooden plugs with C.P. brass scews (B) 600mm x 20mm size.
96 Providing and fixing screw down bib taps of following size.(A) Brass screw down bib 48.00 No 214.81
tap polished bright. (i) 20mm dia.
Item Rate In
Description of Item Quantity Unit Amount
No figures
97 Providing and fixing pillar tap, capstan head, screw down high pressure with screws, 18.00 No 308.73
shanks and back nuts. (i) 15mm dia.
98 Providing and fixing chromium plated brass half trun flush cock of approved quality 28.00 No 263.77
including fixing in pipe line etc. complete (ii) 25mm dia.
99 Providing laying (to level or slopes) and jointing reinforced concrete Light duty non- 661.00 Rmt 678.01
pressure pipes I.S. class NP2 of the following internal diameter with collars and butt
ends prepared for collar joints including testing of joints complete. (D)
100 Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water 4.00 No 1246.92
tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight (i)
Square mouth traps (B) 150mm x 100mm size P or R type
101 Constructing brick masonry chamber for underground C.I. Inspection chamber and 18.00 No 3223.92
bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5
precast RCC cover 455mm x 610mm intenal dimensions with frame (R.C.C. top slabe
with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and bed concrete etc. complete (i)
Inside dimensions 455mmx 610mm and 450mm deep for single pipe line.
102 Constructing brick masonry chamber for underground C.I. Inspection C.I. Inspection 11.00 No 3933.95
chamber and bends with briocks having croshing strength not less than 35Kg. Cm2 in
C.M. 1:5 precast RCC cover 500mmx 700mm intenal dimensions with frame (R.C.C. top
slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and bed concrete etc. complete (i)
Inside dimensions 500mmx 700mm and 450mm deep for single pipe line.
103 Constructing brick masonry chamber for underground C.I. Inspection chamber and 10.00 Each 242.39
bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5
precast RCC cover 455mm x 610mm intenal dimensions with frame (R.C.C. top slabe
with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and bed concrete etc. complete (i)
Inside dimensions 455mmx 610mm and 450mm deep for single pipe line.
Extra over items for every additional depth of 0.1M. of part thereof beyond 450mm
depth for Brick masonry chamber.(i) for 455mm x 610mm size.
Item Rate In
Description of Item Quantity Unit Amount
No figures
104 Constructing brick masonry chamber for underground C.I. Inspection C.I. Inspection 5.00 Each 264.86
chamber and bends with briocks having croshing strength not less than 35Kg. Cm2 in
C.M. 1:5 precast RCC cover 500mmx 700mm intenal dimensions with frame (R.C.C. top
slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and bed concrete etc. complete (i)
Inside dimensions 500mmx 700mm and 450mm deep for single pipe line.
Extra over items for every additional depth of 0.1M. of part thereof beyond 450mm
depth for Brick masonry chamber.(i) for 500mm x 700mm size.
105 Providing and fixing GI Ladder of required pattern with GI flats(30x3mm) or round or 900.00 Kg 95.95
square bars (12mm) at required spacing & with round headed bolts and nuts or
screws or welding including primer coat of approved quality and two coats of oil
paintas as directed by engineer in charge
106 Providing and fixing 0.75 meter wide sand which type counter platform including 13.00 Sqmt 6407.44
supplying and fixing granite stone of Z black or equivalant quality 18 mm thick mirror
polished on top and side posiition and vertical strip at front with cement slurry &
adhesive including moulding of both exposed edges over 25 mm thick kotah stone
platform fixing in top and sides and itermediates supports fixing with cement mortar
and adhesive and finishing all material and labour and assessories and 3 no flat back
wash with necessary fitting MI Fisher , Waste pipe and coupling , 15 mm pillar cock
etc. complete etc.
107 Providing and fixing 0.45 meter wide sand which type platform including supplying 12.00 Sqmt 3491.57
and fixing granite stone of Z black or equivalant quality 18 mm thick mirror polished
on top and side posiition and vertical strip at front with cement slurry & adhesive
including moulding of both exposed edges over 25 mm thick kotah stone platform
fixing in top and sides and itermediates supports fixing with cement mortar and
adhesive and finishing all material and labour complete etc.
108 Providing and fixing in position 300 mm high, 150 mm wide English letters made from 100.00 No 707.00
1.0 mm thick stainless steel sheet as directed by Engineer in charge with all necessary
tools & plants etc. complete.
109 Providing and fixing in position 150 mm high, English letters made from 1.0 mm thick 150.00 No 404.00
stainless steel sheet as directed by Engineer in charge with all necessary tools & plants
etc. complete.
110 Providing and laying and fixing 50 mm thick expansion joint by hydro cell semi rigid 117.00 Sqmt 1491.03
UV resistance with high performance laminated closed cell polythene foam joint filler
in sheet foam as directed, etc. complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
111 Applying and providing Expansion joint sealing System on 100 mm vide joint including 117.00 Sqmt 4772.00
cleaning of exansion joint by mechanical means provision of adhesive and flexible
membrane with required bond length as per menufracturer specification and 4mm
thick alluminium strip covering with one side sloted and bolted with suitable system,
inclusive of all manpower, machinery and material as per specification and as
112 Providing and filling the expansion joint by Thioflex 600 polymer or equivalent 117.00 Sqmt 515.39
confirm to BS 4254-1983 as per required shade and manufactured specifi-cation by
making groove of 50 mm x 12.5 mm lather by cutting or by repairing groove and
removing mortar drop or any other foreign materials including applying primer and
filling required size (oversize of joint PU foam etc. complete.
113 Providing and fixing 25 cm Wide & 3mm thick exterior composite panel on existing 39.00 Sqmt 1054.34
expansion joint horizontally & vertically with all material, hardware, acessories &
fittings etc completed.
114 Supplying and Fixing Z clamp with type G.I.Brackets for SWR/RWR/Water supply 1070.00 No 121.20
Plumbing all type of dia pipe with GI Clamp and Nacessary Fastenrs
115 Design, supply & installation of Name/Number Plate including lettering made of 8.00 Sqmt 5858.00
polyvinayl of approved color on 1 mm thick stainless steel (SS 304) sheet as approved
by Architect or Engineer-in-charge. For all floor
116 Providing and Fixing Size: L 75mm x W 75mm x H 1200 ; 15 mm thick U shape corner 25.00 No 616.81
Rubber Reflective Guards with yellow reflective Patti fixing on RCC/brick surface
Including all fitting and material charges & it shall be Chemical Resistant, Fade Proof,
Frost - Heat & Weather Proof, High Flexural Strength, Highly Durable, Stain Resistance
as per detailed drawing etc. complete as directed by Architect or Engineer in charge.
117 Supply and Installation of Corner Guard protection system fixed to brick wall/or 60.00 No 1723.67
tile/dado at the corner from finished floor level. It should be adjustable end cap.
S.S.plate of 304 grade “100mm wide x1.54mm thickness x 1200mm length “. Corner
guard system consist of following: PVC cover, base, top and bottom end cap in
different color etc complete.
118 Providing and Fixing 15 mm thick 300 mm x 300 mm Tactile Warning Tiles (Attention 30.00 Sqmt 1210.08
Tiles i.e. Tactile Warning Surface Indicator {TWSI}) of Johnsan Endura Tac Button
Yellow Plus or equvqlent make in flooring laid on 20 mm thick cement mortar 1:6 (1
cement : 6 coarse sand) on new surface and jointed with cement slurry including
finished with flush pointing & cleaning the surface for all floors as per detailed
drawing etc. complete as directed by Architect or Engineer in charge. Thse tiles shall
be Anti Skid, Chemical Resistant, Fade Proof, Frost - Heat & Weather Proof, High
Flexural Strength, Highly Durable, Stain Resistance . All Tactile Warning Tiles meet the
specific size and dimension standards as required by ISO/FDIS
Item Rate In
Description of Item Quantity Unit Amount
No figures
119 Providing and Fixing a set of wall mounted horizontal stainless steel collapsible grab 12.00 Set 2671.45
bar and vertical stainless steel fixed grab rail of grade SS 304 from round pipe
supported with 75 mm dia 8 mm thick SS 304 base flange on wall including anchor
fasteners, nuts, accessories as per detailed drawing etc. complete as directed by
Architect or Engineer in charge.
120 Providing and fixing acrylic multilingual Braille (raised dots) DIRECTIONAL 1.00 No 1765.08
SIGNBOARDS of size 225 x 150mm designed as per accessibility standards and having
3.5mm thick acrylic base plate with Upper Case San Serif words made of white acrylic
non glare cut out letters of height 15mm raised not less than 0.8mm above base plate
and the equivalent word written in Hindi with Devanagari non glare acrylic letters of
height 15mm raised not less than 0.8mm above base plate and having a non-glare
acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per
manufacturers specifications on the wall at the approved location and at a height of
1200mm from FFL complete as per design / specifications and guidelines as per the
entire satisfaction of the Engineer-in-charge
121 Providing & Fixing Braile Indicator Of Size 170 Mm X 35mm For Handrails Of The 1.00 No 945.76
Approved Design And Make Have Braile Dots Raised 0.5 Mm Above Base Plate To Be
Installed At Specific Locations As Per Direction Of Engineer In Charge
122 Providing and fixing of conspectus tape 50mm width on of treads in staircase 90.00 No 2199.88
including cutting pasting etc. As per harmonised guidelines complete in all respect to
the entire satisfaction of engineer in charge.
123 Providing and Fixing 6 mm thick Lexan Polycarbonate multi wall roofing sheet fixed 257.00 Sqm 1441.90
with hilti screw and rubber silicon sealer and alluminium strip of size 50 x 3 mm etc
complete as directed by Engineer in charge.
124 Steel work, welded in built up sections framed work including cutting, hoisting, fixing 24276.00 KG 91.08
in position and applying a priming coat of red lead paint. (A)In beams and joists,
channels angles Tees, flats, with connecting plates or angle cleats as in main and cross
beams. Hip and jack rafters, purlins conneted to common rafters and the like
125 Providing and fixing on floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the 190.00 Rmt 339.05
following outside Dia. Low densidy, complete with special falnge compression type
fittings, wall clipsetc. including making good the wall ceiling and floor.(G)110 mm
126 Providing and fixing on floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the 120.00 Rmt 696.90
following outside Dia. Low densidy, complete with special falnge compression type
fittings, wall clipsetc. including making good the wall ceiling and floor.(G)160 mm
Item Rate In
Description of Item Quantity Unit Amount
No figures
127 Providing junction for rain water juncton chamber of size 0.60x0.60x0.75m with 12.00 Nos. 9224.33
excavation of size 1.96x1.96 m & 0.15m thick c.c.1:2:4 bed concrete including brick
masonary wall in CM 1:6 of 0.75m height & 0.23m thick with 15mm thick cement
plaster inside & outside & 1.06x1.06 RCC (1:2:4) slab of thickness 0.15m with CRS
steel and 0.60mx0.45m cast iron manhole cover with frame weight not less than 35 kg
as per directed by Engineer-in-charge
128 Providing Filter chamber of Brick work in C:M 1:6 of size 2.06mx1.20m x1.20m & 2.00 Nos. 16863.97
excavation dimension of 2.66mx 1.81x1.35m including C.C 1:2:4 bed concrete of 0.15m
thick including brick work in c.m 1:6 for 23cm thick wall including 15mm thick cement
plaster inside & outside with cement slurry & 10cm thick RCC 1:2:4 top cover with
frame of minimum weight of 35 kg & filling filter material kapchi in layers (25-40mm
& 10-20mm) & BT metal 40mm & sand as per directed by Engineer-in-charge.
129 Providing and installation Recharge pit of “RAIWOHA” Make 3 layer RCC Precast 1.00 Nos. 109645.60
Injection well system of size 1.5 meter Dia. X 3.4 Meter Height rein forced concrete
precast three layer module with 6” dia x 12” dia. V wire screen of 0.75mm x 1.0 mm
Slot size in SS 304 material and 1.0 meter height with MS Top cover and required Air
vent including all necessary excavation and transportation at site including required
filter media for the recharge system as per site requirement.
130 Drilling of min. 250 mm dia. bore hole in all strata including dualover burden strata by 100.00 Rmt 1270.58
combination DR/DTH rig including lowering 200 mm dia MS ERW pipes in bore hole
and testing etc.all work as per directed engineer incharge.
131 Supplying slotted PVC pipes of approved quality at site of work confirming to IS. 100.00 Rmt 555.50
1239/1974 180mm dia.
132 Cleaning & maintenance of system Including all Labour and replacing of Filter Media 1.00 Nos. 4646.00
as Required for one year
133 Providing and laying cement concrete 1:2:4 (1- Cement : 2- Coarse sand : 4- graded 65.00 Cumt 3786.47
stone aggregates 20 mm nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth
134 Providing 15mm thick cement plaster in single coat on Rough (Similar) side of single 368.00 Sqmt. 222.24
or half birck walls / concrete wall for interior plastering and finished even and smooth
in C M 1:4 (1 cement : 4 coarse sand) with floting coat of neat cement slurry etc. comp.
For Ground floor
Item Rate In
Description of Item Quantity Unit Amount
No figures
135 Constructing brick masonry chamber for underground C.I. Inspection chamber and 6.00 No. 7180.44
bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 C.I.
cover with frame (Light duty) 455mm x 610mm intenal dimensions, total weight of
cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg.
) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate
20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar
1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc.
complete.(iii) Inside dimensions 600mm x 850 mm and 450mm deep for pipe lines
with three or more inlets.
136 Providing and laying (two level or slopes) and jointing with stiff mixture of Cement 95.00 Rmt. 526.46
Mortar in proportion 1:1, Salt glazed stone ware pipes of pipes 150mm laying lime
concrete 1:2:4 (1-Lime putty :2-Fine samd : 4-Graded brick aggregates 40mm nominal
size) bedding for stoneware pipes of following internal diameters with necessary
formwork and curing complete.
137 Providing laying (to level or slopes) and jointing reinforced concrete Light duty non- 100.00 Rmt 3225.56
pressure pipes I.S. class NP2 of the following internal diameter with collars and butt
ends prepared for collar joints including testing of joints complete.(M) 1200mm
138 Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1 cement :2-coarse sand : 4- 6.00 No 23470.48
graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement
: 3 coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with
Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat
cement and making channels in cement concrete 1:2:4 mix (1-Cement :2 Coarse sand
:4-stone aggregate 20mm nominal size) finished smooth complete including curing
and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with
frame size 560mm diameter total weight of cover and frame to be not less than
kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick
msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement
Mortar 1:5 (1- Cement: 5-Coarse sand) (3) C type depth 2.25 Metre for 150mm
diameter sewer
139 Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and 35.00 Cumt 291.09
stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.
(D) Soft rock not requiring Blasting
140 Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size having weight not less 2.00 Nos 958.17
than 35Kg.
141 Providing & erecting open well horizontal mono block pump set with cast iron body, 2.00 Nos 36107.50
complete for three phase submersible motor having [H]For 15 H.P,3 phase open well
horizontal mono block pump set suitable for 1600 LPM to 1025 LPM @ 33 to 42 MTR
head suitable for 65/80 mm dia delivery pipe
Item Rate In
Description of Item Quantity Unit Amount
No figures
142 Supplying & erecting approvedmake 3 phase motor control cubicalpanel (Star-Delta) 4.00 Nos 19695.00
made from 16G.CRCA sheet duty painted with epoxy powder painted inside and
outside with hinged doors and locking arrangement, consisting suitable size of ON-
OFF isolator (AC- 3/23duty) main fuses,single phasing preventer cum water level,
Guard(Compe unit), Toggle switch to by pass Single phase preventercum
WLG,indicating lamps forR-Y-Bphases, over load relay.Automatic water level
duty socket Crimped,Panel to be erected on angle iron frame grouted on wall as
overload relay,thermal/Electronics star delta cutoff timer,start-stop push buttons.The
isolator overload relay &cntractors ofL&T,Siemens or Cuttler Hamer make only.Panel
to be erected on angle iron frame ground on wall (e)S/D upto 2.5 H.P.
143 Providing and fixing rolling shutters of approved make made of 80 mm wide M.S laths 10.00 Sqmt 3554.40
inter-locked together through heir entire length and jointed together at the ends by
end locks mounted on specially designed pipe shaft with bracket plates,guide channels
and arrangement for inside and outside locking with push-pull operation including the
cost of hood cover and sprig etc.complete(A) Shutters having width below 3.5M
144 Providing and laying water proofing treatment with broken chine mosaic flooring for 75.00 Sqmt 765.97
terrace using 12 mm to 20 mm broken pieces of glazed tiles to be laid over cement
mortar 1:3 to plain or slope and to be tempered to bring mortar creme out upto
surface using white cement including rounding off junctions and extending them upto
15 cm along the wall, clearing with water and oxalic acid etc. as directed.
145 Providing and laying cement concrete flooring 1:2:4 (1-cement : 2-coarse sand : 4- 75.00 Sqmt 358.71
graded stone aggregate 20mm nominal size) laid in one layer and finished with a
floating coat of neat cement. (B) 50mm thick.
146 Drilling of min. 250 mm dia. bore hole in all strata including dualover burden strata by 400.00 Rmt 865.57
combination DR/DTH rig including lowering 200 mm dia MS ERW pipes in bore hole
and testing etc.all work as per directed engineer incharge.
147 Manufacture, supply and delivery of cage typeTrapezoidal shape ( ' V ') wire wound 400.00 Rmt 1682.66
low carbon, Galvanized screen pipe and Stainless Steel Screen pipes, confirming IS:
8110 For (B) 200mm dia 1) 1.00mm Slot size
148 Bore plug having 100 mm height made from M.S. plate with 3 holes at equal distance 1.00 No. 1161.62
on circumference for nut-bolts type, locking arrangement with nuts-bolts & lock nuts
of std. Make complete. For 250mm dia
149 Providing PVC insulated flat submersible cable as per detailed technical specifications 400.00 Rmt 121.20
of R/C of GWSSB conforming to IS 694, IEC 60227 / 60228.d)1 R x 3 C x 6.0 mm2
Item Rate In
Description of Item Quantity Unit Amount
No figures
150 Suppling and installing 3 Phase Borewell 3.0 HP Submersible Pump Sets Electric motor 1.00 Set 37130.63
driven conforming to I.S. 8034 and motor conforms to IS-9283 working at 3 phase
400/440 volt 50 C/S A.C. supply & 2900 R.P.M. cat
151 Providing and fixing check or non return pully wheel valve of 50 mm diameter. 1.00 No. 1111.00
152 Manufacture, supply and delivery of following ISI marked HDPE pipes (IS:4984/1985 390.00 Rmt 152.51
with latest amendment) having material Grade PE-80 in approximate 100 meter coil
length or as per GWSSB requirement with SS 316 nipple at both ends having 11 TPI
threads as per specifications, press fitted and bolted having nominal diameter as
under as per detailed technical specifications.
153 Box cutting the road surface to proper slope and camber for making a base for road 1059.00 Cum. 106.65
work including removing the excavated stuff and depositing on the road side slope as
directed upto 50Mt.lead.
154 Filling in plinth with sand under floors including watering ramming, consolidating and 177.00 Cum. 363.60
dressing complete for road work
155 Construction of granular sub-base 150 mm thick by providing coarse graded machine 265.00 Cum. 1122.11
crushed B.T. material satisfying MOST specification of grading I (B.T. stone aggregate
53 mm to 26.5 mm 35 %, 26.5 to 4.75 mm - 45 % and 2.36 mm below - 20 % )including
spreading in uniform layer with motor grader on prepared surface, mixing by mix in
place method with rotavator at OMC and compacting with vibratory roller to achieve
the desired density etc. complete.
156 Providing and laying wet mix macadam base course 250 mm thick using machine 441.00 Cum. 1182.71
crushed B.T. chips as per required gradation mixing with required optimum quantity
of water, conveying the mix to site of work, spreading in to grade and camber with
mechanical paver and consolidation each layer with vibratory roller including cost of
material labour plant and equipment etc. complete.
157 Compaction and finishing of cement concrete road by trimix M.250 process providing 1764.00 Sqm. 63.63
extra Labour charges for the trimix vacume dewatering service process on cement
concrete road sutface by using vacuum dewatering pump floater surface vibrator
including making groves and rough finish to surface including leveling etc complete.
158 Providing and Laying homoginious Grey cement based concrete kerbing of size 30 cm 752.00 Rmt. 370.68
x 30 cm x 10 cm size as per detailed drawing having grade of concrete M25 grade,
including necessary excavation, BBCC 1:5:10 7.5 cm as per ddetailed drawing fixing in
line and level, filling joints in CM 1:3 with smooth finished, white washing three coats
etc. complete as directed by Engineer in charge.
Item Rate In
Description of Item Quantity Unit Amount
No figures
159 Supply. installation, testing & commissioning of ISI approved Horizontal Split-Case 1.00 No. 325000.00
type electrical motor driven main fire pump set having 97 m3/hr. @ 70 m head.
Kirloskar make, Horizontal end suction, back pullout, top discharge centrifugal pump
with gland packed, with all standard accessories base frame, coupling & coupling
guard and foundation bolts.The pump unit shall be a horizontal direct mounted
motor. Motor speed shall be 3000 rpm. Unit shall comprise the following minimum
requirements:
a) Pump, b) Electric motor IE 2 type, c) Foundation bolts, d) Air release valve, e)
Mating flanges with gasket and fasteners, f) Discharge gauges, etc. complete in all
respect. Model DB 80/26. R Motor 40H.P. / 2900 rpm. with labour, with GST.
160 Supply. installation, testing & commissioning of ISI approved Horizontal Split-case 1.00 No. 525000.00
type diesel engine driven stand-by fire pump set having 97 m3/hr. @ 70 m head. The
pump unit shall be a horizontallly mounted, coupled with diesel engine. Unit shall
comprise the following minimum requirements:
a) Pump, b) Diesel Engine, c) Coupling, d) Air release valve, i) Mating flanges with
gasket and fasteners, k) Discharge gauges, etc. complete in all respect.
Pump shall be coupled with suitable diesel engine with heat exchanger cooled/water
cooled (radiator type) complete with base frame, anti-vibration rubber pad, coupling
with coupling guard and foundation bolts, etc. engine shall have have a speed of 1800-
2000 rpm. Engine shall be complete with flywheel, spider coupling, air cleaners,
corrosion resistor, oil sump with lube at pump, governor, fuel filter, starting motor,
battery charging alternator & instrument panel suitable for 24 volt DC including
starting switches, lead acid batteries of 24V & 180 amp-harrating with termination,
diesel engine controller with supply cable from main panel to DEC, suitable capacity of
diesel oil tank (including first fill) with all accessories, lube oil temperature gauge, lube
oil pressure, level gauge & high water temperature, flexible exhaust connection &
exhaust pipe with silencer (insulated with asbestos rope), etc., with all complete. with
labour, with GST.
161 Supply. installation, testing & commissioning of ISI approved Vertical In-line type 1.00 No. 94660.00
electrical motor driven jockey pump set having 10.8 m3/hr. @ 70m head. The pump
unit shall be a vertically direct mounted motor. Unit shall comprise the following
minimum requirements:
a) Pump, b) Electric motor IE2, c) Foundation bolts, d) Mating flanges with gasket and
fasteners, e) Discharge gauges, etc. complete in all respect, with labour, with GST.
162 Suppy, Installing, Testing and Commissioning of Normax make C.I. Heavy duty foot 2.00 No. 13936.00
valve with flangs, Nut bolts, Gaskets etc. with necessary complete accessories. 150 mm
163 Suppy, Installing, Testing and Commissioning of Normax make C.I. Heavy duty foot 1.00 No. 4500.00
valve with flangs, Nut bolts, Gaskets etc. with necessary complete accessories. 80 mm
Item Rate In
Description of Item Quantity Unit Amount
No figures
164 Supply, installation, testing & commissioning of common control panel suitable for for 1.00 No. 235000.00
main electrical motor driven fire pump (1no.), Auto start of diesel engine driven
standby fire pump, & jockey electrical motor (1 no.) Auto start of Main and jockey
pump, fire red powder coated Motor Control Center with Aluminium busbar and
weather proof enclosure (IP 54) motor control center (MCC). MCC enclosure shall be
facbricated from CRCA sheet, door & partition shall be 14 SWG complete with
incomer, Star Delta/DOL starter bus bar, protective fuses, indicating lamps with
interlock facility with bottom/top entry with foot mounting (on channel frame) type
complete with all accessories.(all componenets of L&T & Schneider/siemens make).
With battery charger tricle/booster arrangement for diesel battery charging.
FRLS Power & control cable for main electric pump including earthing from motor
control centre (MCC panel) to pump & all instruments (pressure switchs) with all
complete. Power cabling & control cabling including earthing from MCC panel to all
pumps & all instruments (pressure switches) inside pump house.
165 Providing and erecting XLPE (IS:7098)(I)88 ISI marked armoured cable multistrand 50.00 No. 336.00
Aluminium conductor for 1.1 KV to be laid with necessary clamps or in existing cable
trench / trays from Fire panel to the motors.
166 Supply, installation, testing & commissioning of Priming tank,HDPE type, min. 1000 1.00 No 55000.00
litres, necessary piping for priming the pumps of 100 mm size, butterfly valves for
isolation, NRV 100 mm to prevent back flow, Water Filling piping min. 50 mm size, to
priming tank ,with all complete.
167 Supply, installation, testing & commissioning of Manifold( surge vessel,)for fire 1.00 set 70000.00
hydrant system, min. 300 mm diameter, made from M.S plate, hydro tested to
kg./cm2. with ball valves, header with couplings for fitting pressure switches,
pressure gauges etc.with necessary isolation valves with all complete.
168 Supply, installation, testing & commissioning of instrumentation for automatic 1.00 Job 20000.00
operation of all pump sets including 3 nos. pressure switches and 4 nos. 150 mm dia.
dial Burdon Type Glycerine Filled pressure gauges with SS syphon & isolation ball
valve arrangements with necessary isolation valves with all complete.
169 Supply, fabrication & erection of aboveground G.I. ERW piping, conforming to IS:1239, 20.00 Mtr. 3258.00
part-I, Heavy C class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy C class for size 150 mm dia.
& below & IS: 3589, min. 6.35 mm, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 200 mm dia.
Item Rate In
Description of Item Quantity Unit Amount
No figures
170 Supply, fabrication & erection of aboveground G.I. ERW piping, conforming to IS:1239, 20.00 Mtr. 2431.00
part-I, Heavy C class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy C class for size 150 mm dia.
& below & IS: 3589, min. 6.35 mm, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 200 mm dia. 150 mm dia.
171 Supply, fabrication & erection of aboveground G.I. ERW piping, conforming to IS:1239, 10.00 Mtr. 1567.00
part-I, Heavy C class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy C class for size 150 mm dia.
& below & IS: 3589, min. 6.35 mm, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 200 mm dia. 100 mm dia.
172 Supply, fabrication & erection of aboveground G.I. ERW piping, conforming to IS:1239, 10.00 Mtr. 1131.00
part-I, Heavy C class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy C class for size 150 mm dia.
& below & IS: 3589, min. 6.35 mm, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 200 mm dia. 80 mm dia.
173 Supply, fabrication & erection of aboveground G.I. ERW piping, conforming to IS:1239, 10.00 Mtr. 575.00
part-I, Heavy C class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy C class for size 150 mm dia.
& below & IS: 3589, min. 6.35 mm, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 200 mm dia. 50 mm dia.
Item Rate In
Description of Item Quantity Unit Amount
No figures
174 Supply, fabrication & erection of aboveground G.I. ERW piping, conforming to IS:1239, 100.00 Mtr. 365.00
part-I, Heavy C class up to 150 mm dia. and IS:3589, for size 200 mm dia. & above,
thickness. G.I. pipe fitting's as per IS: 1239, part-II, Heavy C class for size 150 mm dia.
& below & IS: 3589, min. 6.35 mm, for size 200 mm dia. above, flanges, nuts bolts &
washers, 3 mm thick gasket, pipe hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support, shall be two coat of zinc primer
and two coats of fire red conf. to IS: 5, Shade 536. Complete with all accessories as per
approved drawings, specicification and direction of the Engineer-in-Charge, with all
complete. 200 mm dia. 25 mm dia.
175 Supply, installtion, testing & commissioing of Underground GI (ERW) piping 20.00 Mtr 3065.00
conforming to IS:1239, part-I, Medium class ('B' class) up to 150 mm dia. and IS:3589
heavy class ('C' class), for 200 mm dia. & above, min. 6.35mm thickness including
Medium class fittings, anti-corrosive tape of size 150 mm wide x 4 mm thick, wrapping
& coating with 13KV holiday testing . Rates shall include sand bedding of 75mm dia all
around, backfilling of the excavated including installation of heavy pipe fitting's,
flanges, etc.
10 % of all the welded joints shall be done radiographically tested and 50% of the
joints radiographed shall be the "Field Joints".
Hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc., complete
with all accessories as per approved drawings, specicification and direction of the
Engineer-in-Charge, with all complete. (Road Crossing) 150 mm dia.
176 Supply, installtion, testing & commissioing of Underground GI (ERW) piping 10.00 Mtr 1995.00
conforming to IS:1239, part-I, Medium class ('B' class) up to 150 mm dia. and IS:3589
heavy class ('C' class), for 200 mm dia. & above, min. 6.35mm thickness including
Medium class fittings, anti-corrosive tape of size 150 mm wide x 4 mm thick, wrapping
& coating with 13KV holiday testing . Rates shall include sand bedding of 75mm dia all
around, backfilling of the excavated including installation of heavy pipe fitting's,
flanges, etc.
10 % of all the welded joints shall be done radiographically tested and 50% of the
joints radiographed shall be the "Field Joints".
Hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc., complete
with all accessories as per approved drawings, specicification and direction of the
Engineer-in-Charge, with all complete. (Road Crossing) 100 mm dia
177 Supply, installation, testing & commissioning of Cast iron body double flanged gate 2.00 No. 18750.00
valve conf. to IS: 14846, PN-1.6 with mating flanges, drilling as per IS/ANSI 150# with
mating flanges, galvanized nut, bolts & washers, gasket 3 mm thick, etc., with all
complete. 150 mm dia.
Item Rate In
Description of Item Quantity Unit Amount
No figures
178 Supply, installation, testing & commissioning of Cast iron body double flanged gate 2.00 No. 10750.00
valve conf. to IS: 14846, PN-1.6 with mating flanges, drilling as per IS/ANSI 150# with
mating flanges, galvanized nut, bolts & washers, gasket 3 mm thick, etc., with all
complete. 100 mm dia.
179 Supply, installation, testing & commissioning of Cast iron body double flanged gate 1.00 No. 7000.00
valve conf. to IS: 14846, PN-1.6 with mating flanges, drilling as per IS/ANSI 150# with
mating flanges, galvanized nut, bolts & washers, gasket 3 mm thick, etc., with all
complete. 50 mm dia.
180 Supply, Installation, Testing & Commissioning of Cast iron body Butterfly valve 2.00 No. 6750.00
according to IS: 13095, PN-1.6, ISI mark, below Lever operated and above 150 mm dia.
Gear operated complete with mating flanges /ANSI class # 150 with bolts & nuts
washers, rubber gaskets 3 mm thick, etc., with all complete. 150 mm dia.
181 Supply, Installation, Testing & Commissioning of Cast iron body Butterfly valve 2.00 No. 5500.00
according to IS: 13095, PN-1.6, ISI mark, below Lever operated and above 150 mm dia.
Gear operated complete with mating flanges /ANSI class # 150 with bolts & nuts
washers, rubber gaskets 3 mm thick, etc., with all complete. 100 mm dia.
182 Supply, Installation, Testing & Commissioning of Cast iron body Butterfly valve 1.00 No. 4550.00
according to IS: 13095, PN-1.6, ISI mark, below Lever operated and above 150 mm dia.
Gear operated complete with mating flanges /ANSI class # 150 with bolts & nuts
washers, rubber gaskets 3 mm thick, etc., with all complete. 50 mm dia.
183 Supply, installation, testing & commissioning of Cast iron body NRV conf. to IS: 5312, 2.00 No. 5517.00
PN-1.6, Dual Plate type with S.S flap, IS mark, complete with mating Flanges/IS/ ANSI
class # 150 with bolts & nuts, washers, gaskets 3 mm thick, etc., with all complete.
184 Supply, installation, testing & commissioning of Cast iron body NRV conf. to IS: 5312, 2.00 No. 3700.00
PN-1.6, Dual Plate type with S.S flap, IS mark, complete with mating Flanges/IS/ ANSI
class # 150 with bolts & nuts, washers, gaskets 3 mm thick, etc., with all complete.
185 Supply, installation, testing & commissioning of Cast iron body NRV conf. to IS: 5312, 1.00 No. 2500.00
PN-1.6, Dual Plate type with S.S flap, IS mark, complete with mating Flanges/IS/ ANSI
class # 150 with bolts & nuts, washers, gaskets 3 mm thick, etc., with all complete.
186 Supply, installation, testing & commissioning of Four way fire brigade Inlet connection 1.00 No. 8000.00
with 63 mm dia. stainless steel (SS304) instantaneous male inlets with built in non
return valve in each inlet with 150 mm dia. header pipe, suitable rubber cap and GI
chain including nuts, bolts, washers, gasket 3 mm thick, etc. with all complete.As per IS
903. ISI mark.
Item Rate In
Description of Item Quantity Unit Amount
No figures
187 Supply, installation, testing & commissioning of Oblique pattern type stainless steel 12.00 No. 4345.00
(SS 304) single headed External Fire Hydrant Valve , ISI, with 63 mm dia. female
instantaneous outlet conf. to IS: 5290, type - A, including mating flanges, galvanised
nuts, galvanised bolts/studs, washers & gaskets 3 mm thick with all complete.
188 Supply, installation, testing & commissioning of 63 mm dia., ISI , stainless steel (SS 12.00 No. 1409.00
304) Universal Branch Pipe conf. to IS:
189 Supply & installation, testing & commissioing of Fire Fighting Hose - conf. to IS : 636, 12.00 No. 4759.00
type - A, ISI, The fire hose shall be 15 m long with 63 mm dia. stainless steel (SS 304)
couplings conf. to IS: 903, at both the ends for connection with the hydrant valve and
the branch pipe.
190 Supply, installation, testing & commissioning of fabricated from 3 mm CRC sheet, hose 12.00 No. 2809.00
boxe of size-750 mm x 600 mm x 250 mm - painted with Fire Redas per IS: 5, shade no.
536 color from outside & white enamel from inside , front 3 mm thick transparent
glass with key, handle and brass hinges - to accommodate 2 nos. of 15 mtr long hose
and 1 no. universal branch pipe, including supporting arrangement with civil work.
191 Supply, Installation, testing & commissioing of Swinging type mild steel hose reel 12.00 No. 5809.00
drum with 20 mm dia. x 30 mtr. rubber hose as per IS:
The mounting stand shall be of mild steel and the hose shall be fitted with a SS shut-off
nozzle & SS ball valve of 25 mm dia. including supporting arrangement with all
192 Supply & Installation, Testing & Commissioing of 25 mm dia gun metal Air Release 4.00 No. 1100.00
valve with 25 mm dia. stainless steel ball valve.
193 Supply, Installation, Testing & Commissioning of Fixed Stand Post Type Water Monitor 1.00 No. 27500.00
as per IS: 8442 , monitor having 100 mm inlet connection with flow of 1750 lpm with
all complete and 100 mm dia. gate valve, IS: 13095, PN-1.6, with mating flanges
drilling as per IS: 6392/IS: 1538/B 16.5/ASA 150#, galvanised nuts, bolts/studs &
washers, neoprene rubber gasket 3mm thick., etc. with all complete.
194 Provide complete demonstration of whole fire system for three years and obtaining 1.00 Job 85000.00
fire NOC from SMC/ Nagar palika for three years as per Govt. rules & Regulations. Fees
for SMC/ Nagar palika for Fire NOC will be paid by department and other services
included in this items except Annual maintenance contract.
195 Design , Supply and installation of Safety signage made of Zinc Sulphilde based glow in 12.00 sq.m 2992.00
dark , Rigid sheet with High Luminous property enclosed in a transperent weather
proof UV stabilized plastic pasted on 3 mm thick clear acrylic sheet such as EXITS,
EMERGENCY EXIT, DO NOT USE LIFT DURING FIRE, FLOOR MARKINGS, FIRE LIFT,
STAIRCASE EXIT, FIRE ALARM CALL POINT, FIRE HOSE REEL, FIRE HYDRANT POINT
Item Rate In
Description of Item Quantity Unit Amount
No figures
196 Supply, installation, testing & commissioning of Basket Type Strainer complete with 2.00 No. 35000.00
mating Flanges/IS/ ANSI class # 150 with bolts & nuts, washers, gaskets 3 mm thick,
etc., with all complete. 150 mm dia.
197 Supply, installation, testing & commissioning of Basket Type Strainer complete with 1.00 No. 13475.00
mating Flanges/IS/ ANSI class # 150 with bolts & nuts, washers, gaskets 3 mm thick,
etc., with all complete. 80 mm dia.
198 Supply, Installtion, Testing & Commissioing of Standard Response Sprinkler, Pendent 30.00 No. 600.00
Brass Sprinkler, Quartzoid Bulb type with crome finish, nickel crome platde, K factor K-
80, Temp.- 680C, 1/2" end connection including resessed escutcheon. (UL Listed).
199 Supplying of 25 mm dia UL Listed SS braided Sprinkler Flexible Hose of having 15mm 30.00 No. 750.00
end connection outlet with supporting arrangement from false ceiling frame and
having max. test pressure of 60 bar and max. working pressure of 12 bar at 149 deg.c.
maximum temperature. (UL Listed)
200 Supply, Installation, Testing & Commissioing of UL Listed Ductile Iron Wet Alarm 1.00 No. 48000.00
Control valve, internally and externally painted, pre-trimmed with bi-pass connection,
test and drain connection, tested to 1.5 times the working pressure, with pressure
gauge, water motor gong, including matching flanges, galvanised bolts/studs, nuts,
washers & gaskets, with all complete. 100 mm dia.
201 Supply, Installation, Testing & Commissioning of UL Listed Water Flow Switch, with 1.00 No. 5500.00
NO & NC Contacts with all complete. 100 mm dia.
202 Supply, Installation, Testing, & Commissioning of Stainless Steel Ball Valve for drain, 8.00 No. 1950.00
with all complete. 50 mm dia
203 Supply, Installation and commissioning of ABC type fire extinguisher, capacity 5 kg. as 12.00 No. 2140.00
per IS 14609 / 15683. With necessary fittings.
204 Supply, Installation and commissioning of CO2 type fire extinguisher, capacity 4.5 kg. 12.00 No 6150.00
as per IS 15222/15683. With necessary fittings.
205 Supply, Installation, and commissioning of Fire Alarm panel , Addressible type, 8 loops, 1.00 No. 225000.00
with complete accessories, Make Honeywell.
206 Supply, Installation, and commissioning of optical smoke detectors with complete 12.00 No. 2300.00
accessories, Make Honeywell.
207 Supply, Installation, and commissioning of Intelligent Wall Mounted Sounder, Red 12.00 No. 5025.00
with Pure White skirt
with complete accessories, Make Honeywell.
208 Supply, Installation, and commissioning of Red Add Call Point, Flush Mounting, Glass 12.00 No 4030.00
with base with complete accessories, Make Honeywell.
209 Armour Cable for Fire Alarm system, two core, 1.5 mm2, FRLS type, 500.00 Mtr 120.00
210 Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I 8.00 No. 1480.00
Sheet with extra handle at bottom duly painted white inside and Red out side with
FIRE mark. Filled with dry-sand and kept on existing stand provided or hung on wall
Item Rate In
Description of Item Quantity Unit Amount
No figures
211 Supplying and erecting floor mounting Stand for keeping four nos. of FIRE buckets 2.00 No. 4000.00
comprising 1500 mm in length, 900 mm height frame made out of 30mm x 30 mm x
mm angle iron with cross suports legs, welded with 4 hooks and duly painted with one
coat of red lead and two coats of approved enamelled silver paint.
212 Providing and fixing of Ridge flashing for roof panel shall be made out of 0.5 mm thick 474.00 kg 867.39
pre coated GI sheet . The Precoated sheet shall be of minimum 240 mpa steel grade
confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per
IS:277:1992 , 5-7 microns epoxy primer on both side of the sheet and polyester top
coat 15-18 micron. The PPGI Sheet shall have plastic protective guard film of minimum
25 microns to avoid scratches during transportation. The ridge shall be fixed to the
steel members by pop rivet or self drilling/self stitching fastners @ maximum 450 mm
c/c along length of capping/flashing etc complete .
213 Constructing providing and fabricating cattle guard using channel section frame of size 24.00 Sqmt 5227.76
ISMC series 100 mm x 50 mm (Weight 9.20 kg/Rmt) and ISMC section 100 mm x
75mm (weight 11.50 kg/Rmt) intermediate support for welding G.I.pipe at 12 Cm C/C
of size 50 mm in a frame made of Channel section size 100 mm x 50 mm all round
including fixing the unit on prepared chamber of masonary wall using MS hold fast
embeded in masonary wall top as directed by Engineer in charge and as per drawing
and necessary required arrangement etc complete.
214 Providing and fixing decorative entrance slidng gate made out of cast iron and various 1980.00 kg 163.62
mild steel tabular section combination , the MS gate with sliding mechanisum of all
including pattern and die making , cutting , welding , grinding, fabrication , fixing in
position at compound wall with necessary pedestal, bearing block and other locking
arrangement. The entrance gate should be painted with two coats of priming coat of
paint, and two coat of oil paint etc complete. As per detail design and instruction of
architect.
215 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm 840.00 Rmt 579.74
dia 10 mt openable length having 50 no rounds per 6 mt length, upto 3mt height of
wall with existing angle iron (50mm x50mm x5mm )requird shaped As per Directed
Engeenier in charge. placed 2.4mt or 3.00mt apart and with 4 horizontal R.B.T.
reinforced barbed wire(3 mm) , stud tied with G.I. staples and G.I. clips to retain
horizontal, including necessary bolts or G.I.barbed wire tied to angle iron, all complete
as per direction of Engineer-in-charge, with reinforced barbed tape (R.B.T.)/Spring
core (2.5 mm thick) and weight 43.478 gm/meter at compound wall for ESR M4/
intakewell.
Item Rate In
Description of Item Quantity Unit Amount
No figures
216 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) 554.00 Pt. 485.81
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up
to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell
push & accessories and earth continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe
erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed. (f) with
medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete Cat. III
217 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of 290.00 Pt. 674.68
.ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected with 6A Modular type switch and hum free EME
step type electronic fan regulator mounted and accessories with earth continuity of
following type erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed. (f)
with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete Cat. III
218 Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket 109.00 Pt. 257.55
erected on PVC / Metallic/Wooden box, single mounting base frame covered with
textured / metallic/white front plate modules erected on / in wall / ceiling with
following type accessories Cat. III
219 Providing following type of Modular Type Accessories mounted with PVC / 15.00 Nos 151.50
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge. (1)One No. SP 6 Amp. Cat.III
220 Providing following type of Modular Type Accessories mounted with PVC / 15.00 Nos 151.50
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge (2) One No 5 pin plug Cat.III
221 Providing following type of Modular Type Accessories mounted with PVC / 29.00 Nos 160.59
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge (3) Two Pin/RJ-11 Telephone Socket [A] For
One Gang Cat.III
222 Providing following type of Modular Type Accessories mounted with PVC / 152.00 Nos 160.59
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge (8) Computer RJ-45 socket Cat.III
Item Rate In
Description of Item Quantity Unit Amount
No figures
223 Providing following type of Modular Type Accessories mounted with PVC / 41.00 Nos 180.79
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge (9) 16 Amp. SP one way switch Cat.III
224 Providing following type of Modular Type Accessories mounted with PVC / 41.00 Nos 140.39
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge (10) 6/16Amp. Universal socket Cat.III
225 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size 7240.00 Mtr. 67.67
complete to be erected on/in wall or ceiling erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in
approved manner as directed (a)20 mm
226 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked 5520.00 Mtr. 82.82
stranded Copper conductor wire in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of following size (A) With medium
class Rigid PVC pipe and accessories (b) 2 wire 2.5 sq. mm
227 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked 820.00 Mtr. 112.11
stranded Copper conductor wire in following type of pipe to be erected in / on wall /
ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (A) with medium class Rigid PVC pipe and
accessories (a) 2 wire 4 sq. mm
228 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked 0.00 Mtr. 147.46
stranded Copper conductor wire in following type of pipe to be erected in / on wall /
ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (A) with medium class Rigid PVC pipe and
accessories (b) 2 wire 6 sq. mm
229 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked 540.00 Mtr. 260.58
stranded Copper conductor wire in following type of pipe to be erected in / on wall /
ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (A) with medium class Rigid PVC pipe and
accessories (h) 4 wire 6 sq. mm
230 Providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, 40.00 Mtr. 91.91
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required size of copper lugs,
nuts and bolts if required. (f) One wire 10.00 sq. mm
Item Rate In
Description of Item Quantity Unit Amount
No figures
231 Providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, 40.00 Mtr. 142.41
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required size of copper lugs,
nuts and bolts if required. (g) One wire 16.00 sq. mm
232 Providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, 40.00 Mtr. 236.34
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required size of copper lugs,
nuts and bolts if required. (h) One wire 25.00 sq. mm
233 Providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, 60.00 Mtr. 470.66
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required size of copper lugs,
nuts and bolts if required. (j) One wire 50.00 sq. mm
234 Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI 196.00 Mtr. 46.46
marked copper wires of following size to be erected as directed. (e) 1.50 Sq.mm 3 core
round PVC sheathed
235 Supplying & erecting approved make Telephone Cable electrolytic copper conductor 1160.00 Mtr. 20.20
PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with
FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT
erected in existing pipe. of following size of conductors & nos.of pairs. With necessary
connections. [A] Conductor Size 0.5 mm (a) Unarmoured (2) Two Pairs
236 Supplying & erecting approved make LAN cable of following size in existing pipe as 6080.00 Mtr. 46.46
per direction [C] CAT -
237 Providing & erecting main Distribution (MDF) indoor type, back mounted frame as per 3.00 Nos. 994.85
DoT standard approved with krone strips (a) Suitable for 10 pair
238 Providing & erecting Switch board for Computer or electric apparatus consisting of 152.00 Nos. 1133.22
following modular type accessories mounted with PVC / Metallic concealed/open box
with single mounting base frame covered with textured/metallic /white front
plate,modules erected with necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type Accessories
239 Decorative call bell Ting-tong box type 250 volts complete erected 5.00 Nos. 71.71
Item Rate In
Description of Item Quantity Unit Amount
No figures
240 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt 507.00 Nos. 540.65
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V,
Power Factor more than 0.95, THD < 15%, CCT 3000 K to 6500K, Luminaire efficacy>
85 lumens/watt, LED driver efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates) (NOTE: Below description have shown ranges of Wattage capacity of LED
shown.) (A) Tube Light with integral driver (v) 36-40 Watts, Surge-2 KV, IP-20,
conventional 4 feet Cat-III
241 Supplying and erecting led lamps with following wattage capacity of 220 to 240 42.00 Nos. 112.11
voltage, minimum 15000 burning hours life, 500 V in built-surge
protection,Polycarbonate diffuser, mounting suitable for E14 / E27 / B22 lamp
holders, pf >= 0.5 (A) LED Lamps integral type, with PC diffuser suitable LAMP holder
(ii) 5 to 8 watts Cat-III
242 Supplying and erecting LED street light / Flood light fittings with High power White 62.00 Nos. 4997.48
LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than
130 lm/w and corrosion free High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.The Engineer
(IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with
over-voltage protection. (ii) above 48 to 60 Watts Cat-III
243 (B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC 16.00 Nos. 7266.95
line supply with over-voltage protection. (iv) above 90 to 120 watts Cat-III
244 (C) Post Top Lantern LED fitting comprises of finish cast aluminum spigot and spun 2.00 Nos. 4819.72
aluminum canopy fixed with opal polycarbonate, pipe arrangement for vertical
mounting driver and accessories wired upto terminal block.IP 65 (ii)32-40W Cat-lll
245 Providing and erecting Approved make Four pole moulded case circuit breaker having 4.00 Nos. 6173.12
breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to
100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s.
with all internal connections, spreader tinned copper & complete erected in existing
16 G.M.S. housing. ICS=100% of ICU only Cat III
Item Rate In
Description of Item Quantity Unit Amount
No figures
246 Providing and erecting Approved make Four pole moulded case circuit breaker having 4.00 Nos. 8136.32
breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A. with
Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all
internal connections, spreader tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III
247 Providing and erecting Approved make Four pole moulded case circuit breaker 5.00 Nos. 16221.61
having breaking capacity ICU of 35 KA. at 415 V. having Normal current rating
200A.with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s.
with all internal connections, spreader tinned copper & complete erected in existing
16 G.M.S.housing ICS=100% of ICU only Cat III
248 Providing and erecting Approved make Four pole moulded case circuit breaker having 1.00 Nos. 25228.79
breaking capacity ICU of 50 KA and above at 415 V having Normal current rating
400A. with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s.
With all internal connections, spreader tinned copper & complete erected in existing
16 G.M.S. housing. ICS=100% of ICU only Cat III
249 Providing and erecting Approved make Four pole moulded case circuit breaker having 1.00 Nos. 28029.19
breaking capacity ICU of 50 KA and above at 415 V having Normal current rating
400A. with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s.
With all internal connections, spreader tinned copper & complete erected in existing
16 G.M.S. housing. ICS=100% of ICU only, Cat III (With Enclosure)
250 Providing and erecting Approved make Earth fault Relay suitable to mount with inter 1.00 Nos. 5415.62
connection suitable to following size of moulded case circuit breaker having CT ratio
& MCCB rating as following along with shunt trip 220V AC. with all internal
connections & complete erected in existing M.S.housing.. (3) 250 A -400 A , CT Ratio
251 Supplying & erecting approved make Four Pole 415V change over switch interior for 1.00 Nos. 22255.35
panel mounting with operating mechanism A.C.23 duty confirming to IS for (F)400A
252 Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper 2.00 Rmt 3202.71
Busbars with four equal Nos. of electrolyte bus having current density not more than
1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour
insulating tape for phase sequence of following current carrying capacity, erected with
necessary bus bar supports /insulators, main cable socket to each bar, erected in
existing cubical panel with necessary connections. (B) Suitable for 200 Amp. capacity
Item Rate In
Description of Item Quantity Unit Amount
No figures
253 Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper 1.00 Rmt 7319.47
Busbars with four equal Nos. of electrolyte bus having current density not more than
1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour
insulating tape for phase sequence of following current carrying capacity, erected with
necessary bus bar supports /insulators, main cable socket to each bar, erected in
existing cubical panel with necessary connections. (D) Suitable for 400 Amp. capacity
254 Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper 4.00 Rmt 13199.69
Busbars with four equal Nos. of electrolyte bus having current density not more than
1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour
insulating tape for phase sequence of following current carrying capacity, erected with
necessary bus bar supports /insulators, main cable socket to each bar, erected in
existing cubical panel with necessary connections. (F) Suitable for 800 Amp. capacity
255 Providing and erecting Miniature circuit breaker single pole 0.5A to 2A system and 80.00 Nos. 270.68
having breaking capacity 10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat.III
256 Providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to 216.00 Nos. 112.11
operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark Cat.III
257 Providing & erecting 240 V MCB double pole switch for motor & inductive load (C 6.00 Nos. 330.27
Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having
following capacity (B) 40 Amp. Cat.III
258 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) 30.00 Nos. 737.30
having 10KA breaking capacity & confirms to IS :8828 in existing box having following
capacity (c)63 Amp. Cat.III
259 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / 12.00 Nos. 2913.85
surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used) suitable for (B) three phase
incoming and single phase horizontal type outgoing Per phase isolation type (PPI) (b)
sheet steel double door (ii)6 way
260 Providing and erecting Approved make RCCBs conforming to IS: 12640 and having 36.00 Nos. 2235.13
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz. having characteristic of quick action & tripping
with all advance feature & do not incorporate any electronic component. for following
Max. rating erected as directed (ii) 40Amps. DP Cat. III
261 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 75.00 Kg. 794.87
Item Rate In
Description of Item Quantity Unit Amount
No figures
262 Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. dia. 25.00 Nos. 368.65
galvanised iron pipe with coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
263 For using salt and charcoal / coke as required for pipe type earthing. 25.00 Nos. 171.70
264 Supplying & erecting earth pit of minimum bore dia.150mm size approved make 2.00 Nos. 4591.46
Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of
corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover. (A)(approved make OEM has to
submit test certificate including value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to ensure the value of earthing resistane
mentioned in test Certificate) & having back filling compound of (B) Inner chemical
(CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017,
Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency. (a) For Electrical Installation up
to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
265 Providing & erecting weather proof, dust & vermin proof, floor mounted front 6.50 Smt. 10468.65
operated indoor type cubical panel board necessary IP-42 and above protection as
per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer
body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary
accesories , supporting angles/ flats channel including cutting, bending, drilling,
welding, riveting with internal partitions & cable alley as per requirements &
instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS,
suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber
grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus &
earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors,
handles with locking arrangement and rubber gasket,heavy duty end terminal
connection,danger notice board,necessary ventilation,earthing strip complete. The
Panel shall be painted with epoxy powder coating. (The rates excludes the cost of
switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters,
Fuses etc. The dimension shall be measured excluding base beams) The panel shall be
supplied with following approved manufacturers with following size. (A) locally
fabricated panel board (i) with 350 mm depth
Item Rate In
Description of Item Quantity Unit Amount
No figures
266 Providing & erecting weather proof, dust & vermin proof, floor mounted front 7.00 Smt. 27134.66
operated indoor type cubical panel board necessary IP-42 and above protection as
per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer
body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary
accesories , supporting angles/ flats channel including cutting, bending, drilling,
welding, riveting with internal partitions & cable alley as per requirements &
instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS,
suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber
grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus &
earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors,
handles with locking arrangement and rubber gasket,heavy duty end terminal
connection,danger notice board,necessary ventilation,earthing strip complete. The
Panel shall be painted with epoxy powder coating. (The rates excludes the cost of
switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters,
Fuses etc. The dimension shall be measured excluding base beams) The panel shall be
supplied with following approved manufacturers with following size. (A) locally
fabricated panel board (iv) with 1000 mm. depth
267 Providing , erecting , fabricating the M.S. structure as per requirement on site 50.00 Kg. 77.77
incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections
complete with cutting, welding, grinding & finishing duly painted with one coat of red
oxide with erection on site as per direction of engineer in charge with necessary
grouting, cementing, plastering & finishing complete.
268 Providing and erecting XLPE(IS:7098) (I)-88 ISI armoured cable multistrand 80.00 Mtr. 220.18
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (B) 3 1/2 core 35 Sq. mm ( 16 Sq.
mm 1/2 core)
269 Providing and erecting XLPE(IS:7098) (I)-88 ISI armoured cable multistrand 30.00 Mtr. 540.35
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (F) 3 1/2 core 120 Sq. mm ( 70 Sq.
mm 1/2 core)
270 Providing and erecting XLPE(IS:7098) (I)-88 ISI armoured cable multistrand 946.00 Mtr. 904.96
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (H) 3 1/2 core 185 Sq. mm ( 95 Sq.
mm 1/2 core)
271 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid 1956.00 Mtr. 126.25
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (B) 4 core 6 Sq. mm
Item Rate In
Description of Item Quantity Unit Amount
No figures
272 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand 150.00 Mtr. 153.52
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (A) 4 core 16 Sq. mm
273 Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating 2428.20 Mtr. 55.55
the fault all over the run and back filling the same and making the surface as normal
274 Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across 150.00 Mtr. 226.24
the road crossing or on floor with necessary material in an approved manner and
making the ground as per original. (F) 100 mm dia.
275 Providing & laying approved make Double walled corrugated pipes (DWC) of 2248.20 Mtr. 62.62
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of
same material at required depth in existing trench for laying of cable. below ground /
road surface for enclosing cable (A)50 mm outer dia
276 Providing & laying approved make Double walled corrugated pipes (DWC) of 240.00 Mtr. 95.95
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of
same material at required depth in existing trench for laying of cable. below ground /
road surface for enclosing cable (C) 90 mm outer dia
277 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC 4.00 Nos. 38.38
insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables. (B) 2 to 4 core 6 Sq. mm
278 Providing and, fixing heavy duty flange type brass double compression type cable 2.00 Nos. 75.75
gland with rubber ring for PVC insulated armoured cable complete with out going
tails, insulating tape etc for following size of cables. (B) 3 & 1/2 core 35/50 Sq. mm
279 Providing and, fixing heavy duty flange type brass double compression type cable 4.00 Nos. 140.39
gland with rubber ring for PVC insulated armoured cable complete with out going
tails, insulating tape etc for following size of cables. (E) 3 & 1/2 core 120 Sq. mm
280 Providing and, fixing heavy duty flange type brass double compression type cable 6.00 Nos. 238.36
gland with rubber ring for PVC insulated armoured cable complete with out going
tails, insulating tape etc for following size of cables. (G) 3 & 1/2 core 185 Sq. mm
281 Providing and, fixing heavy duty flange type brass double compression type cable 12.00 Nos 247.45
gland with rubber ring for PVC insulated armoured cable complete with out going
tails, insulating tape etc for following size of cables. (H) 3 & 1/2 core 240 Sq. mm
282 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of 200.00 Nos. 6.06
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an approved manner. (A) 1.5/
Item Rate In
Description of Item Quantity Unit Amount
No figures
283 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of 10.00 Nos. 20.20
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an approved manner. (D) 35/50
284 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of 34.00 Nos. 45.45
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an approved manner. (G)
285 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of 18.00 Nos. 80.80
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an approved manner. ( I )
286 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of 12.00 Nos 85.85
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an approved manner. (J)
287 Supply, Installation, Testing and Commissioning of suitable sweep, BEE 5 Star rated, 290.00 Nos. 2885.57
Ceiling fan with Brush Less Direct Current (BLDC) permanent ferrite magnet Motor,
class of insulation: B, Rust free 3 nos.Aluminium blades, 2 nos. canopies, shackle kit
with earthing provision, copper winding, Power factor not < 0.9, Service Value
(CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM,230v (tolerance
as per IS : 374-2019), THD < 10%, with remote unit for Speed Control and all
remaining accessories including safety pin, nut bolts, washers, temperature rise =
degree C (Max.), suitable for 140 to 285 Voltage and rectifier circuit with surge, over
current and overload protection , 50 Hz, Single phase AC Supply, earthing etc.
Complete as required.[ Make shall be approved by Engineer in Charge] (B) 1200 mm
Sweep (48")
288 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod 290.00 Mtr. 108.07
erected duly painted for fan complete with proper insulation without leakage and
289 Supplying & erecting Fan Hook of 10 mm M.S. Round bar grouted in RCC slab with 290.00 Nos. 43.43
Making the site as original.
290 Supplying and erecting approved make Octagonal pole made from HR sheet steel. The 49.00 Nos. 6874.06
pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with integral Junction box
consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and arrangement for cable termination to
be erected With Suitable foundation (Included) as per details given by manufacturer
considering site requirement. (C) 5 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm
thickness with 200mmX200mmX12mm base plate, 4-M16 Bolts and 600mm long with
necessary G.I. J Bolts .Approx Pole weight 46 kg
Item Rate In
Description of Item Quantity Unit Amount
No figures
291 Supplying & erecting approved make SMC press moulded composite FRP. loop-in, 16.00 Nos. 476.72
loop-out approx. 2mm thick box complete with Bakelite connector strip
5way(3P+N+E),DIN rail for mounting mob & hinged doors as per requirement having
locking arrangements with mounting clamp with nuts, bolts & washers suitable for
erection on pole with cable clamps& earth bolt of following size of box. (C)150mm x
125mm x 100mm [deep]
292 Supplying and erecting Street light pole bracket comprising main B Class GI pipe of 4.2 36.00 Nos. 491.87
cm/require outside dia. complete with suitable B Class G.I. sleeve tubing of approx.
45cms.length and suitable for 76.5mm/80mm/require size of pole top having nuts and
bolts for fixing the brackets and having spread of 0.5 mtr. Length with 110 deg.with
vertical plane and suitable welded stiffener reducer and nipple with check nut
complete painted with one coat.of Red oxide / PU base primer and two coats of
Aluminium / PU paint. paint with following nos of arms. [A] Single Arm bracket 0.5 Mtr
293 Supplying and erecting Street light pole bracket comprising main B Class GI pipe of 4.2 13.00 Nos. 622.16
cm/require outside dia. complete with suitable B Class G.I. sleeve tubing of approx.
45cms.length and suitable for 76.5mm/80mm/require size of pole top having nuts and
bolts for fixing the brackets and having spread of 0.5 mtr. Length with 110 deg.with
vertical plane and suitable welded stiffener reducer and nipple with check nut
complete painted with one coat.of Red oxide / PU base primer and two coats of
Aluminium / PU paint. paint with following nos of arms. [B] Double Arm Bracket
294 Supplying & erecting IP 55 grade following size section pillar fabricated from joint less 3.00 Nos. 3595.60
M.S. Sheet with angle iron legs made from jointless M.S. Angle with cable clamps to be
buried in ground to have appropriate erection to work uniform until erected with
cement concrete foundation and 45 cm high bricks work finishing with plaster etc.
hinged double door internally supported on both side, with internal and outside
looking arrangement with look and keys in duplicate 35 x 35 x 5 mm M.S. Angle of Two
Nos. one is welded and other with nut and bolt for erecting Bakelite sheet. Painting the
Section Pillar inside and out side with three tank powder coated paint. section pillar
roof should be without joint with water leakage proof & tested as per IP 55 test &
followed by IS 2147 of 1962 (B) 75 X 60 X 45 cm section pillar fabricated from
Gauge MS Sheet with angle iron legs 45 cm long made from 35 X 35 X 5 mm thick MS
295 Supplying & erecting approved make Digital time switch having lithium cell 6 years 8.00 Nos. 3168.37
operative and operate battery backup 1 channel day clock with 14 memory
programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum
switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF
switching. Programming switches & housed in fire proof thermoplastic enclosure &
transparent cover erected as required with necessary connection erected as directed.
296 Supplying & erecting power contactor ,AC3 duty for time switch complete erected as 8.00 Nos. 2782.55
per direction Cat III (D) 4 pole 440V 40 Amp.
Item Rate In
Description of Item Quantity Unit Amount
No figures
297 SITC of Digital / PCM / TDM EPABX System having SMT design, system with flexible 1.00 Nos. 77077.14
universal slots. Inbuilt Auto attendant facility, Minimum 15 Nos. conference, Analog
extension line, Calling GSM, E&M line, PRI / EI & VOIP program me through Analog
telephone digital key from Ethernet, public address cord, shall have unrestricted
simultaneous dialing facility, QSIG protocol on PRI, 95 / STD / ISD / Local-Locking,
Class of Service, Quick Dial-Single Digit dialing of any two external number, Once only
ring device, Chairman / Secretary - Do not disturb Facility, Power Down Mode, Hot
Line, Hot Outward Dialing, Day Night Mode, Auto Call Back, Barge-in, Call Pick Up &
Call Transfer, Call transfer while Ringing with Voice Guide System, (DISA), Caller ID
(CLI), CLI Base ECF, CLI Base routing Internet Ready Port, External Music Port, Call
Budgeting, Call Most Calculation (ASMDR), DID Direct Inverse Dialing, External Music
Input, Fax Homing, Global Directory Printing with following capacities [[Approved by
Competent Authority i.e. not Below the rank of Executive Engineer ] [C] No of
Extension 48, No of Junctions 9, 8 Port IP Resource in-built, 4 Port Web base Video
Conferencing, No of expandable ports : 128, Operators Console - 01 Compatible : ISDN
298 Supplying & erecting push button type telephone instrument having speaker phone 29.00 Nos. 898.90
Caller ID & speaker phone with one touch memory (min.6 nos.)& 99 memories with
display system Single line [[Approved by Competent Authority i.e. not Below the rank
of Executive Engineer ]
299 SITC of 3LCD Lamp based projector having wxga (1280x800) or better resolution with 2.00 Nos. 33895.60
minimum white brightness of 3800 lumens and color brightness of 3800 lumens. The
projector should have minimum 1HDMI,1VGA input. Having contrast ratio of 15000:1
or more. the projector should have auto vertical key stone correction of +/- 30 degree
and Manual Horizontal of +/-30 degree. the projector should have optical lens, throw
ratio 1.30-1.56:1. Zoom Factor of 1.2. Lens focus Manual having focal length 16.9mm to
20.28mm. projector should have features like AV mute slide, quick corner and split
function and should support wireless functionality with inbuilt wifi or wifi dongle.
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
300 SITC of 100 inch Self Lock MW (7 x 5) Instalock Slow Retraction Screen, Aspect Ratio- 2.00 Nos. 3810.73
4:3 [Approved by Competent Authority i.e. not Below the rank of Executive Engineer
301 Providing and erecting Inverter based approved make split air-conditioning unit 8.00 Nos. 56353.96
consisting of condensing unit with variable speed fan motor, inverter type
hermetically sealed rotary compressor with accessories etc. duly connected separately
erected evaporating unit and blower motor with its accessories by means of extra
supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes
Eco Friendly green gas charging and 15A plug top & Remote Control & MS Stand) with
necessary core cutting. (1)For 3 Star Rating of current year (C) for 1.7 to 2 ton
capacity - Premium Cat.
302 Supplying and erecting insulated pair of soft copper tubing open or concealed 40.00 Rmt. 746.39
including power and control cable,necessary PVC drain pipes for Split AC machine up
to 4 TR capacity
Item Rate In
Description of Item Quantity Unit Amount
No figures
303 Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity 6.00 Nos. 55893.40
150 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should
drop by 15˚C within a hour, The water cooler should be comprising of hermetically
sealed compressor, fan motor, condensing unit, water tank surrounded by
evaporating, coil, thermostats, relay etc.complete with necessary inlet & outlet
connection. The body of water cooler will be made from Stainless Steel.
304 Supplying & erecting reverse osmosis (RO) water purification system with M.S. 6.00 Nos. 77891.20
powder coated pedestal frame, prefilter housing carbon filter suitable buster DC
pump, auto low & high pressure switches with following size of LPH capacity & erected
as directed [D] 100 LPH with 1 phase / 3 phase Raw water pump of 500LPH @
2.5kg/cm2 - (1N0 - Kirloskar /CRI/Lubi), Dual media filter 10"x54" - (1 No), Micron
cartridge filter 20" x 2.5" ( 1No), High pressure pump 500LPH @ 10kg/cm2 - (1No -
Shimge /CRI /Lubi), RO Membrane housing with RO membrane of 40*40 - (1No), RO
pressure tube 4" x 1E - ( 1No), 0 - 1200LPH Rotameter -(2 Nos), with Recovery Rate
305 Supplying and erecting approved make panel mounting type Digital Voltmeter having 3.00 Nos. 1275.63
3 digits LED display, 0 to 750 AC Volts range erected on existing panel board with all
connection, wiring etc .with manufacturers calibration certificate.
306 Supplying and erecting approved make panel mounting type Digital Ammeter having 3.00 Nos. 1558.43
3 digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to
operate on 500 Volt AC , erected on existing panel board with all connection, wiring
etc .with manufacturers calibration certificate.
500 V on existing panel board with necessary connections.
308 Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15.00 Nos. 274.72
15 VA burden erected in existing CRCA box duly secured with insulating materials
connected to the meter
309 Supplying and erecting approved make suitable panel indicator LED type lamp, lens 45.00 Nos. 43.43
cover, complete erected with necessary connections.
310 SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm 2.00 Nos. 9416.23
long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse
current withstand test: 100 kA of 10/350µs waveform in an accredited Third party
laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST 34mm dia
mm long- Cold Galvanized
311 SITC of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per 60.00 Mtr 299.97
IEC 62561- 2 conducted in the Govt. accredited thirty party laboratory to meet the
requirement of IS/IEC 62305 with Required Accessories - Aluminium Holding clamp at
every 1 mtr distance, Aluminium/SS cross splicer at every crossing of Alu. conductor,
Expansion piece with connectors at every 20 mtr distance, Aluminium straight Splicer
to connect conductors. All Accessories should be tested as per IEC 62561-1 2018 Cl.
6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse current withstand test:
100 kA of 10/350µs waveform(Ageing & Electrical test ) conducted in a sequence
manner & tested in the Govt. accredited Third party laboratory to meet the
requirements of IS/IEC
Item Rate In
Description of Item Quantity Unit Amount
No figures
312 SITC of 10 mm MS Round Solid Conductor having smooth surface Should be tested and 60.00 Mtr 728.21
use exclusively for lightning protection (Vertical Riser/Down Conductor which shall be
concealed in Column OR Flushed on) to meet the requirement of IS IEC 62305 With
Accessories - Earthing stud of dimension SS-75mm OD plate with 10mm dia tail
connector used in structural steel ring earthing system to meet the requirements of
IS/IEC 62305. (For Interconnecting the Column and the Terrace AL Conductor /
Strip/Flat), SS Cross Connector to connect Earth fixing point to vertical raiser/Down
conductor, SS Straight Splicer at every 4 Mtr to connect MS conductor in column,
Bonding /Rebar Clamp at every 3 mtr suitable for interconnecting round conductor
with reinforcement inside the concrete for structural earthing system, SS connector -
To connect external conductor 8- 10 mm with earth fixing point. All Accessories
should be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Test &
for Lightning impulse current withstand test: 100 kA of 10/350µs waveform(Ageing &
Electrical test )Conducted in a sequence manner & tested in the Govt. accredited Third
party laboratory to meet the requirements of IS/IEC
313 SITC of 14.2 mm dia 3 mtr long Earth electrode of High tensile steel electrode with 250 4.00 Per Set 5564.09
micron copper bonding & 1 bag of Carbon fill Based environment friendly backfill
tested as per IEC 62561-7 in NABL accredited Laboratory and suitable stainless Steel
double sided clamp. Eco Friendly rust proof heavy duty weather proof Polyethylene
Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia
(bottom) & 260 mm (height). ENERGY AUDIT & SAFETY AUDIT
314 Providing and erecting iron clad cable route marker duly marked with ELE.CABLE of 240.00 Nos 240.38
size 23 cm.X 12 cm. Flushed with ground in cement foundation as directed by Engineer
in charge.
315 Supplying and erecting approved make online Un-interruptible Power Supply system 2.00 Nos 270989.06
comprising flat cum-boost charger with IGBT base rectifier & Inverter & sealed
maintenance free SMF batteries. The charger having operating capacity for input 160-
270V AC & inverter having output 230V,50 Hz Ac with 0.8 load power factor with
battery, over/under voltage output with over load & short circuit protection
equipment. The system housed in CRC sheet duly powder coated paint with following
power backup.with MS painted batteries stand, 10% Overload capacity for momentary
load(I) 10 KVA 3 - phase with 1Hr Backup
316 Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ 20.00 Kg 794.87
Transformer, LT panel board, Motors etc. using copper clamp.
317 Providing and erecting ISI Marked 3core 120 Sq.mm XLPE insulated 11 KV armoured 90.00 Mtr 1542.27
cable Aluminium conductor IS-7098 to be laid on wall with clamps or in provided
cable trench / pipe approved manner as directed.
318 Approved make standard Draw out type 4 Pole Air circuit breaker. Having 50 kA 3.00 Nos 106197.46
breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse voltage=12 kv
with following type of relay and accessories.(1) Electrically Draw out type (EDO) with
following type of relay system(B) with microprocessor Release with over load, short
circuit, earth fault protection and metering display in modular design with LED display
and Test Trip button facility, CTs and auxiliary contacts, of following current ratings.
(i) 800Amp 50 kA Cat III
319 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand 210.00 Mtr 1168.57
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (I) 3 1/2 core 240 Sq. mm( 120 Sq.
mm 1/2 core)
Item Rate In
Description of Item Quantity Unit Amount
No figures
320 Covering of cable with second class bricks or cement tiles laid cover the cable 199.50 Mtr 140.39
crosswise & also on both sides with covering of 7. 5 Cm. layer of sand above & below
cable (16 bricks per meter)
321 Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar 90.00 KW 42156.39
Power Plant with
Solar Panels (ALMM approved): Frame Material : Anodized Aluminum alloy Frame
With Twin Wall Profile, Front Cover : High Transmission Low-Iron Tempered Glass
(AR Coated), High efficency and positive power tolerance Pmax: 0/+5, Module
Efficiency should be approx. 18%-21%,DCR panel, Normal operating temperature
45'C, Junction Box with Waterproof IP67 & MC4 Compatible and Enclosed with Bypass
diodes, 100% Electroluminescence test to ensure error free Modules, Thep. temp. co-
efficient of the PV module shall equal or better than -0.45%/degree C. Solar PV
modules of minimum fill factor 75% to be used. Unit Production:- 4 to 5 Unit /kw /day
(Actual)(1Year Avg) With 10 year Product warranty and 25 year Linear Power
Warranty.,
Solar Inverter: MPPT Range: 80-1000 V, Max efficiency: 97.5% - 98.9%, O/p
Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi:
<3%, Operating Tempreture Range: -25~60°C, Anti-islanding Protection: (D) Grid
Tied Solar Power System: 26 - 50 kW (3 - phase)
Total Rs.
Ten crore sixty seven lakh sixty eight thousand eight hundred thirty seven rupees and fifty four paisa only.
I/We am/are willing to carry out the work at………………….% above/below percent(Should be written in figures and words) of the estimated rate
mentioned above. Amount of my /our
Tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
In words In words
The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which no extra
1 payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 Income tax TDS will be deducted at a source while making payments of bills
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement
Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the cost of
4 difference of cement consumption have been deducted from the rate of original item at the rate of input rate mentioned in all the tender.
Executive Engineer
Tapi ( R & B ) Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD-Tichakpura.pdf
BOQ-Tichakpura.pdf
SPECIFICATION-tichakpura.pdf
Building-Specification Booklet (2 side).pdf
PQ-Tichakpura.pdf
GRs - SBD with Index (2 side).pdf
5.0 Approved make list 2013 2014 Part 1.pdf
6.0 Approved make list 2013 2014 Part 2.pdf
Electrical Work- Specification (Electrical Work).pdf
Electrical-SPECIAL CONDITIONS.pdf
NOMINETED ELECTRICAL SUB –CONTRACTORS.pdf
SPECIAL CONDITIONS FOR ROOFTOP SOLAR.pdf
drawing ANS SCHOOL SITE PLAN.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .