Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC HQ CE SC PUNE | PUNE | MAHARASHTRA | 410301 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹43.7 L+₹2.1 L (5.16%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹44.1 L+₹2.6 L (6.15%)Rejected-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹45.1 L+₹3.6 L (8.59%)Rejected-AOC KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹47.9 L+₹6.3 L (15.2%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹81,000
Closing Date
23 Apr 2022, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
ADDITION / ALTERATION TO MES INSTALATIONS / SUB-STATIONS AT CGDHQ NO-1 PORBANDAR UNDER GE I CG PORBANDAR
2022_MES_516381_1
8744
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE I CG PORBANDAR
₹81,000
Yes
21 May 2022
4 Apr 2022
25 Apr 2022
4 Apr 2022
23 Apr 2022
18 Apr 2022
4 Apr 2022 - 16 Apr 2022
Amount
SCHEDULE 'A'
Excavating in trenches n exc 1.5 m wide & n exc 1.5 m depth and getting out soft/loose soil.
Excavating in trenches n exc 1.5 m wide & n exc 1.5 m depth and getting out Soft/disintegrated .
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed.
M&L Reinforced cement concrete type A1 1:1.5:3 (20 mm graded aggregate) in foundation, footing, foundation beams, plinth beams, base of columns complete all as specified and as directed.
M&L Reinforced cement concrete type A1 1:1.5:3 (20 mm graded aggregate) Columns, pillars, piers, posts and struts . Complete all as specified and as directed.
M&L Reinforced cement concrete type A1 1:1.5:3 (20 mm graded aggregate) in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M&L Reinforced cement concrete type A1 1:1.5:3 (20 mm graded aggregate) in slab supported on walls, complete all as specified and as directed.
M&L for Formwork to flat sides with fair finish surface of concrete foundations, footings, bases of columns, raft and raft beams sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter
M&L for Formwork to sides of pillars,posts, struts, piers, columns and stanchions with rough finish surface
Form work to sides and soffits of floor or roof beams, beam haunching,lintel etc.
Form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200 mm thick in sloping.
Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips.
-ditto- all as per item No. above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders
M&L for broken stone or boulders Hardcore of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified.
M&L for 100 mm thick Plain Cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base of floors all as specified
M&L for 100 mm thick Plain Cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in sub base of floors all as specified
M&L for 75 mm thick Plain Cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in sub base of floors all as specified
M & L Porbandar stone masonry, well bonded, bedded and solidly hearted built in CM 1:6 all as specified and as directed by Engineer-in-charge.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed or bedding layer of 15 mm thick 1:6 etc. complete all as specified and as directed by Engr-in-Charge
M & L Machine cut kota stone slab flooring 20-22 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over 20 mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M & L Machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over 15 mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M & L coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
All as item no 22 above but over screed bed or bedding layer 10mm thick 1:4 on vertical surfaces/skirting including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge
M & L coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
M&L glazed coloured ceramic tiles in verticle surfaces 450x 300x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over screed bed or bedding layer 10mm thick 1:4 and pointed in white or coloured cement to match complete dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and as directed by Engr-in-Charge.
M&L 20mm thick cement plaster in cement mortar 1:4 mixed with 2% of water proofing compound as in roof treatment when conc is green complete all as specified and directed.
M&L APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely. (ii) Applying APP based pre-fabricated with non woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method. (iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over mineral surface.
M & L for powder coated Aluminium frame and shutter for sliding & openable, door, windows, partation & ventilators (movable louvers type) with one or more rebates including joining cleats for fixing etc. Rubber gasketting all round the panels / shutters to fix glass, PVC gasketting in all channels, locking arrangement, (minimum thickness of powder coating 60 micron for windows, door, partation and ventilators with natutal matt fininsh) complete all as specified and directed. [Note :- (i) Glass to be measured and paid separately under respective of work. (ii) Items shall be paid as per weight of aluminium section. (iii) The quoted rate shall be inclusive of rubber gasket/ PVC gasket, glazing clips, screws etc as required which shall not be measured for arriving the weight. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel arround contacting surface of aluminium work]
S & F Aluminium anodised grill (thickness of anodising minumum 15 micron) with and including suitable aluminium anodized 'F'/ 'H' section frame 23.40 x 15.30 x 1.40 mm thick with aluminium rebated/ screwed attachment complete all as specified and directed in following situation :- (Note : (i) Aluminium grill shall be of 'Deco grill' of M/s ELESAR FOCCHI Ltd as per Design No. DG102, 7.50 mm x 6 mm and weight shall not be less than 3.131 Kg/ Sqm or approved design in M/s Royal Grill/ National Grill/ Alumigrille of M/s Alumi Profiles Pvt. Ltd, Chandramukhi Basement, Nariman point, mumbai.
S&F Float glass 5.5mm thick plain provided to aluminium frame for door/window/partition with necessary aluminium powder coated snap beading and rubber gasket/packing complete all as specified and directed by Engr-in-Charge
S&F Aluminium xpm wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with wooden beads complete as specified and directed by EIC.
Taking down chowkats or frames with shutters (without taking off shutters from frames) size n. exc 1.5 sq mtr each complete all as specified and as directed by Engr-in-Charge
-ditto- but size exc 1.5 Sqm & n.exc 4.00 Sqm each.
Taking down shutters of any description exc 1 sq.m and n exc 2 sq m each and refixing in same opening complete all as specified and as directed by Engr-in-Charge
S&F Plain, solid, straight chowkats and frames, of II class hardwood wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed by Engr-in-Charge
S&F hold fasts and similar small articles conforming to Fe 410-0 or 310-3.
S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panesls, commercial type on bothe sides complete all as specified and as directed by Engr-in-Charge
M&L for 0.9mm thick decorative laminate type 1 of surface finish, colour and patters as approved, fixed with approved adhesive as per manufacturer's insturctions, complete all as specified and as directed by Engr-in-Charge
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC Sheet rainforced with MS square tube complete all as specified and as directed by Engr-in-Charge
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engr-in-Charge
S&F 4mm thick frosted sheet glass, ordinary quality and glazing with oil putty in square in exc 0.5 sq.m in each pane complete all as specified and as directed by Engr-in-Charge
S&F Butt hinges, 100 mm medium weight, cold rolled mild steel complete all as specified and as directed by Engr-in-Charge
S&F for 150 mm size hasp and staple, safety type, aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and as directed by Engr-in-Charge
S&F Extruded aluminium alloy handles, fabricated type, anodised 150 mm complete all as specified and as directed by Engr-in-Charge
S&F Aluminium, anodised, barrel tower bolts 200 mm long of extruded section and fixed complete all as specified and as directed by Engr-in-Charge
S & F for Multipurpose locks 02 levers for cabinet etc with keys complete all as specified and as directed by Engr-in-Charge
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed by Engr-in-Charge
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15 mm dia complete all as specified and as directed by Engr-in-Charge
Supply and laying of CPVC pipes, of 20mm dia SDR -11 including plain CPVC SDR fittings for Hot/cold water for sizes (outer dia ) mentioned below including all fittings and solvents and special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor etc, Unions, Flange and tank adapter all asper manufacturers recommendations and complete all as specified and as directed by Engr-in-Charge
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 20 mm dia complete all as specified and as directed by Engr-in-Charge
Supply and laying of CPVC pipes, of 25mm dia SDR -11 including plain CPVC SDR fittings for Hot/cold water for sizes (outer dia ) mentioned below including all fittings and solvents and special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor etc, Unions, Flange and tank adapter all asper manufacturers recommendations and complete all as specified and as directed by Engr-in-Charge
M&L in repair bib taps cast copper alloy fancy type chromium plated scresed down screwed for iron pipes 15 mm dia.
S&F in repair Pillar taps cast copper alloy with capstan heads, chromium plated fancy type scresed down high pressure, with or without lettered Hot or Cold with long screwed shanks and flynuts screwed for iron pipes 15 mm dia all as directed by Engr-in-Charge.
M&L in repair Chromium plated shower rose 125 mm dia with shower arms with or without swivel joints including fixing to steel pipe or union.
S&F in repair vitreous china wash down water closet (pedestal pattern) with plastic seat and cover including PVC low level flushing cistern 10 ltrs capacity complete as directed by Engr-in-Charge.
S&F in repair Vitrus china orrisa pan squatting pattern 580 X 440mm with integeral foot rests including P or S trap, PVC low level flushing cistern 10 ltrs capacity complete as directed by Engr-in-Charge.
S&F in repair vitreous chine wash hand basin flat back size 550x400 mm including brackets and cutting for and pinning in ends of brackets or erecting stand including waste CP coupling of PTMT and PVC waste pipe of 32 mm dia.
S&F Health Faucet square with 1 mtr tube and hook complete all as specified and as directed by Engr-in-Charge, fixed in repair. Make : Prayag (Cat Pat No-BEA-85) as approved by Engr-in-Charge
S&F Tubular towel rail CP Brass, 60cm long between flanges complete all as specified and as directed by Engr-in-Charge
S&F Soap Dish Polycarbide, Make : Jaquar (Cat Pat No AQN-7733) or equivalent as approved by GE. complete all as specified and as directed by Engr-in-Charge
S&F shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minium weight 300 gms) complete all as specified complete all as specified and as directed by Engr-in-Charge
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed by Engr-in-Charge
S & F in repair sinks drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed by Engr-in-Charge
S&F 50mm bore High density polyethylene (LDPE) pipes of pressure rating 6kgf/sq.cm laid in trenches or in any position complete all as specified and as directed by Engr-in-Charge
S&F 25mm dia ball valves high pressure of PTMT epoxy coated aluminium rod & high density plastic ball screwed for iron pipes and fixed complete all as specified and as directed by Engr-in-Charge
Dismantling water tanks cpacity exc 500 and n exc 1000 ltrs and removing to store
S&F 1000 litre capacity rotational moulded polythylene water storage tanks (cylindrical, vertical with closed top ) hoisted and fixed in positionall specified in SSR Part-I. complete all as specified and as directed by Engr-in-Charge
S&F Gun-metal, globe or gate valves 25 mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-Charge
S&F Gun-metal, globe or gate valves 20 mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-Charge
S&F 20mm dia aluminium decorative type powder coated curtain rod or similar articles complete all as specified and as directed by Engineer in Charge
S&F aluminium decorative type powder coated brackets suitable for 20mm dia curtain rod or similar articles complete all as specified and as directed by Engineer in Charge
M&L for 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed by Engr-in-Charge.
Taking up or down PVC pipes, in any class, 75mm bore (including all fittings) including disconnecting pipes and fittings complete all as specified and as directed by Engr-in-Charge.
Taking up or down PVC pipes, in any class, 110 mm bore (including all fittings) including disconnecting pipes and fittings complete all as specified and as directed by Engr-in-Charge.
Taking up or down PVC pipes, in any class, 160 mm bore (including all fittings) including disconnecting pipes and fittings complete all as specified and as directed by Engr-in-Charge.
S&F 160mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wall including GI clamps of approved shape and size approved by GE
S&F 160mm dia PVC (SWR) bends/shoes any radius.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls of bore 110mm (rates includes for making good disturbed surfaces). complete all as specified and as directed by Engr-in-Charge.
-ditto- all as per item No 78 above, but 75mm dia.
S&F PVC (SWR) bends any radius of 75mm bore. complete all as specified and as directed by Engr-in-Charge.
-ditto- all as per item No above, but 110mm bore.
S&F PVC (SWR) branch piece, single(Y) equal or unequal of 75mm bore.complete all as specified and as directed by Engr-in-Charge.
S&F PVC (SWR) junction single (single T) equal or unequal of 75mm bore complete all as specified and as directed by Engr-in-Charge.
S&F PVC(SWR) vent cowl as specified of dia 75mm bore complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, pillars, etc complete all as specified and as directed.
Demolition of cement concrete( reinforced( reinforcement cut as required to faciliate demolition) of any description and in any position not otherwise specially provided for complete all as specified and as directed.
M&L for demolation of cement concrete (unreinforced) in ground floor and paving not exc.15cm thickness below or above ground level.
M&L for rendering 10 mm thick on fair face of brick work or concrete surfaces in CM 1:6 finished even and smooth wiithout using extra cement.
M&L for rendering 15 mm thick on fair face of brick work or concrete surfaces in CM 1:4 finished even and smooth wiithout using extra cement.
M&L Rendering on ceiling 5 mm thick in CM 1:3 on brick work or concrete surfaces finished fair and even without using extra cement.
M & L Preparing old plastered / decorated surface of wall including cornices etc by brooming down and applying one coat of oil bound distemper including a wherever requred of wall putty including smooth roller finish complete all as specified and directed by Engineer in Charge. (Note after painting cleaning of all floors,glass & furniture by own arrangement).
M & L Preparing new/old plastered / decorated surface of ceillingl including cornices etc by brooming down and applying one coat of oil bound distemper including a layer of wall putty including smooth roller finish complete all as specified and directed by Engineer in Charge. (Note after painting cleaning of all floors,glass & furniture by own arrangement).
M&L Two coats of OBD on new plastered surfaces of wall over a coat of chalk white primer including preparation of newly plastered surfaces complete all as specified and as directed by Engr-in-Charge.
M&L Two coats of OBD on new plastered surfaces of ceiling over a coat of chalk white primer including preparation of newly plastered surfaces complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of wall and applying two coats of weather proof acrylic exterior emulsion paint over a coat of acrylic primer all as per the manufacturers instructions, complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soft/disintegrated rock.
Removal of excavated rocks exc. 1.5 Km but n.exc 5 Km and depositing where directed at level n exc. 1.5M above the starting point. all as specified.
S & F 1.25mm thick Galvanised rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; eerected in position as indicated, complete; but gear operated type with chain wheel and hand chain etc competed al as specified and directed by Engineer in Charge.
M&L preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of epoxy paint over a coat of red oxide primer etc complete all as specified & directed by Engr-in-Charge.
S&F Pre cast RCC Garden Bench without hand rest (03 Seaters) 1.Each bench consists of 2 Nos L-shape base support in grey cement color (thickness: 100mm, Back height: 1000mm, Front height 450mm and base width 620mm) and 5 Nos. Reinforced Concrete planks in color of size 1500mm x 100mm x 50mm and 1 no of Reinforced Concrete planks of size 1500mm x 200mm x 50mm, 2.Overall Dimension Seating lenght of the bench 1500mm, Seating height of the beanch 450mm, Total height of the bench 1000mm, Colour and Design Approved by GE. etc Competed as per Specifed and directed by Engr in Charge
Taking down carefully aluminium/copper point wiring (light,fan,socket or power) concealed and casing caping complete including fittings and fixtures such as switches,ceiling roses,pendants,regulators,sockets light fittings and making good the disturbed surfaces of walls/ceiling/floor etc.
Disconnecting of unserviceable sub main wiring of any size and accessories & removing from site and making good the disturbed surfaces.
Disconnecting electric connections and taking down old unserviceable MCB SPN/SP/TP and DB's of any capacity.
Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:-
(a) One light point controlled by one, one way switch
(b) fan point point controlled by one, one way switch
(b) One 3 pin 6 Amps socket outlet on same board
(c) One 3 pin 6 Amps socket outlet on independent board .
Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame for modular switches, sockets, switch sockets for one 3 pin 15 or 16 Amps on independent board with required modules all as specified. insulated but unsheathed multistrand copper conductor FRLS cabel 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sqmm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board as specified. Note for item no 1/2 :- Cost of cutting / chasing on wall and making good after repair deemed to be included in unit Rate
Point wiring complete with 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame for modular switches, sockets, switch sockets for one 3 pin 15 or 16 Amps on independent board with required modules all as specified. insulated but unsheathed multistrand copper conductor FRLS cabel 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 4 Sqmm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board as specified.
Supply & fix modular switch 1 way, 6 Amps, 1 modular (ISI marked).complete all as specified and as directed.
Supply & fix modular switch 1 way, 16 Amps, 1 modular (ISI marked).complete all as specified and as directed.
Supply & fix modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed.
Supply & fix modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed.
Supply & fix modular fan regulator, 120 watt, 2 moduler (ISI marked).complete all as specified and as directed.
Supply & fix ceiling rose, surface bakelite, 65 x 17 mm three terminals (ISI Marked) complete all as specified and as directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFMwith service value 6.00 BEE. Five starrated with brushless direct current motor (BLDC) and all as specified and directed. Make : Havells/Usha/Bajaj
Taking down and Fixing/Painting only ceiling fan 1200/1400 mm sweep as obtained from taking down vide including painting of celing fan and reffixing at exsisitng location complete all as specified and as directed
S & F in replacement of wall mounted LED Tube light fitting 1 x 20W LED Tube T8, 4 feet including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site on 02 Nos new round/sqare blocks complete all as specified and directed.
M&L for sub main wiring with two single core 4 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 4 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
M&L sub main wiring power/circuit using FRLS PVC insulated unsheathed, stranded copper conductor cable 1 x 6.0 sq. mm single core, earth continuity conductor cable (FRLS) of size 1 x 6 Sqmm to be drawn through and including PVCconduit 32 mm dia medium grade rigid non metallic complete all as specified and as directed.
M&F for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200A, neutral link, with metal double door, including cutting chases exc 10 cm but not exc 20 cm girth for DB and making good disturbed surfaces complete all as specified and as directed.as per the follwing
SPN 8 way
SPN 4 way
SPN 12 way
M&l in replacemnt of MCB DB TPN made of sheet steel phosphatised, powder painted with bus bar 100A, neutral link, with metal double door of 4 way including cutting chases exc 10 cm but not exc 20 cm girth for DB and making good disturbed surfaces complete all as specified and as directed.
Supply and fix 4 Pole MCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specifed and as directed
Supply and fixing in replacement of MCB SP, 240 volt, 6 to 32 Amps complete all as specified.
Supply and fixing in replacement of MCB SPN, 240 volt, 40 Amps complete all as specified.
S & F Double pole and earth enclosure with a three pin and earth plug and socket complete with one triple pole MCB DP 20 Amps.
Supply and fixing LED Bldg Security light /street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete
Supply & fix LED tube light aluminium housing batten with an effieieint diffuser of 10 watt CCT(K) 6500 K along with fixture, complete all as specified and as directed.
Supply & fix exhaust fans, heavy duty, single phase 230/ 240 V of size 450 mm sweep with louveers complete all as specifed and as directed
Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 3 to the earthing test point all as specified and indicated including testing on completion
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil complete all as specified and directed.
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 185 sq. mm 3 core
Supply and Lay of OD Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings laid in trenches/road/nallah or fixed along wall poles or laid under floor for the 110 mm dia
Supply and fix cable jointing kit for 11 KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for3 core XLPE, armoured, Al conductor cable of size 120 Sqmm to 185 Sqmm of size .
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 Sqmm to 300 Sqmm 3 core.
S & F of GI steel tubing light grade 100 mm dia for laying in ground and road crossing along the pole in coping etc for cable protection including necessary fittings, clamps for supports, etc and all as specified and directed. Make - Tata/Jindal/Surya Prakash
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil complete all as specified and directed.
Supply , Installation & commissioning of factory made,indoor type manufactured by CPRI approved manufacturer, self supporting totally enclosed LT Panel Board confirming to IP-55 ,compartmentalized design, dust & vermin proof of suitable size for 440 Volt 3 phase 4 wire system madeup of CRCA sheet of 2.0 mm thick built upin rigid frame work having front and rear hinged door with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip point and ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. having control circuit diagram with colour code solid conductor copper 1.5 sqmm cable for easy identification including Incoming/ Outgoing cable holes at bottom, embeded with 50x6mm mild steel angle Iron frame and 200 mm above the normal ground level complete with PCC foundation in cement concrete 1:2:4 (20mm graded stone aggregate) and testing after installation including taking down unserviceable LT panel board complete all as specified and comprising with the following :- Make : Legrand (Sigma control system) /BCH/ C&S(Ascent Engineering).
Supply , Installation & commissioning of factory made,indoor type manufactured by CPRI approved manufacturer, self supporting totally enclosed LT Panel Board confirming to IP-55 ,compartmentalized design, dust & vermin proof of suitable size for 440 Volt 3 phase 4 wire system madeup of CRCA sheet of 2.0 mm thick built upin rigid frame work having front and rear hinged door with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip point and ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. having control circuit diagram with colour code solid conductor copper 1.5 sqmm cable for easy identification including Incoming/ Outgoing cable holes at bottom, embeded with 50x6mm mild steel angle Iron frame and 200 mm above the normal ground level complete with PCC foundation in cement concrete 1:2:4 (20mm graded stone aggregate) and testing after installation including taking down unserviceable LT panel board complete all as specified and comprising with the following :- Make : Legrand (Sigma control system)/BCH/ C&S(Ascent Engineering).
M & L for disconneting the incoming and outgoing HT cable connection from tranformer160KVA , 315 KVA, VCB 800 AmpRemove the tranformer/VCB from foundation,shifted to another place, and install the tranformer/VCB at the same location and making the incoming and outgoing HT cable connection complete all as specifed and as directred Note ( For shifting of tranformer by hydra machine and other tools are required are deemed to be incldued in unit rate ).
M & L for disconneting the incoming and outgoing LT cable connection from D G Set Remove the dg set from foundation. DG sets Shifted and install to another place and making the incoming and outgoing cable connection complete all as specifed and as directred Note ( For shifting of DG sets by hydra machine & transportation and other tools are required are deemed to be incldued in unit rate ).
M & L for disconneting the incoming and outgoing HT cable connection from tranformer 1000 KVA Remove the tranformer shifted to another place, and install the tranformer at the another location and making the incoming and outgoing HT cable connection complete all as specifed and as directred Note ( For shifting of tranformer by hydra machine and other tools are required are deemed to be incldued in unit rate ).
M&L for bore Earthing, 150 mm bore for earthing with maintenance free chemical earthing using copper electrode of size 19 mm dia - 01 No, 3 m long, Copper earth strip, excavation and earth work, back fill with compound (Chemical for earth enhancer gel 2 x 25Kg) - 01 set. all as directed, shall be deemed to be included in the unit rate. Note: (i) IR Value should be less than 1.0 ohm. (ii) Copper earth stip of size 32 x 6 mm including installation 7.5 Mtr (Copper purity not less than 99%) is deemed to be included in the unit rate. (iii) Suitable FRP Chamber should be included in the unit rate.
S&F Fabricated Rolled mild steel chequered plate as in Duct cover , square cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified and directed by Engineer-in-Charge.
S & F Fabricated rolled mild steel angle iron of size 50mmX 50 mm X5mm, as in nosing to edges of cable duct for resting MS cable covers, including embeding in concrate and screwing etc or directed and similar work conforming to Fe 290 Gde E-165.for ducting
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 70 sq. mm 3.5 core
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm complete all as specified and as directed
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70to 95 sqmm complete all as specified and as directed
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 120 to 150 sqmm complete all as specified and as directed
M & L for making of display board for showing of Ext electrical system with marking of HT and LT supply of stations on board Size 1.7 x 1.5 mtr and ss railing on the side making of stand with angle iron and fixing with PCC complete all as specified and as directed
S & F electrical shock tretment chart of standard size fixing on wall complete all as specified and as directed
Supply and fixing fire bucket iron stand suitable fire bucket of GI body inclduing painting with red paint complete all as specifed and as directed
Supply and fixing fire bucket of GI body inclduing painting with red paint of capacity 1 to 10 Ltr complete all as specifed and as directed
Supply and fixing fire Mechnical foam Extingusher of 9 Kg body material of Mild steel with stand and red paint complete all as specifed and as directed
Supply and fixing fire Dry powder Fire Extingusher of 6Kg body material of Mild steel with stand and red paint complete all as specifed and as directed
Supply and fix rubber insulation mat for LT of size 2 mm x1mmx 2 mtr complete all as specified and as directed
Supply and fix rubber insulation mat for HT of size 3mm x1mmx 2 mtr complete all as specified and as directed
Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion
Taking down old unservicable strip of earthing of any size and make complete all as specifed and as directed
Supply and fixing copper strip of size 32 x 6mm buried in ground complete all as specified and as directed
Supply and fixing GI strip of size 32 x 6mm buried in ground complete all as specified and as directed
Leo Elevator Company
Vijay Construction Co
JAY BHARAT METAL SUPPLIERS
SURAJ ENTERPRISE
K K Construction Co
shree chamunda enterprise
roxy enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .