Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-Finance | ₹4.8 L | L1 | Accepted-Finance Accepted subject to the approval of higher authorities |
| Sl No | Description | Qty | Unit | Jincy Mathew L1 |
|---|---|---|---|---|
| 1.00 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead: With cement mortar 1:4 ( 1 cement : fine sand) | 30 | m2 | 575 ₹17,250 |
| 2.00 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer | 470 | m2 | 147.63 ₹69,386.10 |
| 3.00 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. | 470 | m2 | 665 ₹3.1 L |
| 4.00 | Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. | 470 | m2 | 142 ₹66,740 |
| 5.00 | Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved | 10 | m3 | 275.05 ₹2,750.50 |
| 6.00 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 9 | m2 | 369.76 ₹3,327.84 |
| 7.00 | Labour engaged for miscellaneous works. Coolie. | 5 | Day | 1,082.18 ₹5,410.90 |
Tender Value
Refer Docs
EMD Value
₹11,000
Closing Date
4 Mar 2026, 4:00 pmClosed
University Engineer
Office of the University Engineer
School of Pedagogical Sciences Rectifying leakage from the roof
2026_MGU_834581_2
UE/DB/E33/2025-2026
Open Tender
Civil Works - Others
MG UNIVERSITY CAMPUS
Please refer Tender documents.
5 documents required · 5 mandatory
₹900
Yes
₹11,000
Yes
12 Mar 2026
25 Feb 2026
7 Mar 2026
25 Feb 2026
4 Mar 2026
25 Feb 2026
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead: With cement mortar 1:4 ( 1 cement : fine sand)
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Labour engaged for miscellaneous works. Coolie.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
NIT1.pdf
Additional Documents • 0.02 MB
Biddocument.pdf
Tender Documents • 1.96 MB
ePaymentform.pdf
Tender Documents • 0.01 MB
BOQ_1416399.xls
BOQ • 0.24 MB
PreliminaryAgreement.pdf
Tender Documents • 0.28 MB
Download all tender documents and submit your bid