Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹2,550
Closing Date
31 Dec 2020, 5:00 pmClosed
Managing Director WBEIDC Ltd
Webel BHavan Salt Lake SEC V EP GP Block KOL 91
Internal Electrical and HVAC work for office renovation at first floor of Webel Bhavan
2020_WEBEL_310774_1
Webel/Bhavan/FF/ElecAC/IDM 20 21/41
Open Tender
IT WORKS ORG
Item Rate
30 days
Salt Lake SEC V
Please refer to the tender docs
6 documents required · 6 mandatory
₹500
WBEIDC Ltd
₹2,550
18 Jan 2021
24 Dec 2020
2 Jan 2021
24 Dec 2020
31 Dec 2020
25 Dec 2020
Amount
TAP OFF DISTRIBUTION BOARD
Manufacturing, supplying, installation, testing and commissioning of wall mounting cubicle type Tap off Distribution Board, top & bottom entry made of 2.03mm thick CRCA MS sheet suitable for 500/415V, AC, 50Hz, 3 Phase & Neutral system complete with PVC insulated Aluminium Bars and interconnection, painting, earthing attachment, gland plates etc with following equipments.
Incoming-
i) 1 no. - 500/415V, 32 A, TP&N MCB (36KA)
ii) 1 set (3nos) - RYB Phase LED Indicating Lamp with 3nos SP MCB.
iii) 32 A, 4P, PVC insulated Aluminium Bus Bars complete with FRP supports.
Outgoing-
i) 1nos - 500/415V, 32 A, 4P MCB (C-Curve, 10KA).
Flexible cable
Supplying and drawing of PVC insulated 4 runs 6 sq.mm, single core copper conductor cables through PVC flexible conduit including necessary termination at both end with copper flat, socket, PVC coupler and consumable materials etc. Necessary drilled hole shall be done on pre-fixed existing Rising Mains cover & Bus Bars of the premises including tools & tackles, labours etc as requird.
DISTRIBUTION BOARDS
Supplying and fixing double door Vertical TPN MCB Distribution board for MCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attchment
Up to 32 A
6 Way Enclosure
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attchment
4 Way Enclosure
Supplying and fixing 240/415 V MCB of breaking capacity 10 KA & C characteristics on din rail of existing DBs and necessary connection
Surge Protective Device
Supplying and fixing Class-2 (T2) 415V, FP Surge Protective Device (SPD) of Imax 40kA/pole mounted on din rail of existing DBs and necessary connection
MV Cable & Termination
Supplying, laying, testing and commissioing of 1.1KV grade, A2XFY XLPE Armoured Aluminium cable of following size with all necessary accessories required for installation on the wall above false ceiling and concealed/surface on wall below the false ceiling, Rate shall include with 2 NOS. 8 SWG GI earth continuity Wire for running earth and all civil work like cutting dressing mending good damages as required. The cable shall be laid underground/on wall/in trench-the rate shall be included necessary clamping arrangement as required.
4 core 10 sqmm
Cable End Termination
Supplying and fixing Double Compression type Gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE armoured cable as below:
4 core 10 sqmm
Finishing the end of following XLPE armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make),tapes,anticorrosive paste & jointing materials:
4 core 10 sqmm
SUB MAINS/CIRCUIT MAINS
Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire ‘'FRLS' – in PVC Rigid/Flexible Conduit 'FRLS' (ISI Marked) on wall/ceiling/Furniture as per site requirement (concealed / surface)
Supplying & drawing of wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire in 20mm size PVC rigid/flexible conduit (as per direction by EIC) 'FRLS' including necessary Fittings and necesaary connections as required
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC.
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC.
Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire ‘'FRLS' – in PVC Casing-Capping on wall/ceiling/Furniture as per site requirement
Supplying & drawing of Wiring in 1.1 KV grade single core stranded 'FRLS' PVC insulated & unsheathed copper wire of following sizes in 25mm PVC casing-capping (as per direction by EIC) including necessary PVC clips, fittings, necessary connections as required
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC.
POINT WIRING
Supplying and carrying wiring for light, fan and dependent socket points by using 16 SWG MS/PVC conduits with threaded joints of required dia as per IS 732, MS conduit accessories, MS/PVC flexible conduit with couplers for drops with accessories, 2 x 1.5 + 1 x 1.5 sq mm, 1100V grade FRLS PVC insulated copper wires approved 6A modular type switches and sockets with plates and all accessories for fixing in modular furniture, GI/PVC boxes and other point wiring accessories and carrying out surface/concealed conduit system of wiring as per requirement with all wiring materials. Conduits shall run on surface of the ceiling above false ceiling and concealed in wall by cutting chase in wall and mending good of all the damages.
All points shall be earthed with 1.5 sq mm FRLS flexible copper wire. Wires shall be terminated at light fixtures with ferrules, 16A, 4 way connector, wire ends shall not be kept loose/bare.
The rate shall also include all accessories of MS/PVC conduits, etc, necessary civil works for embedding conduits and boxes below false ceiling, wherever applicable.
1 light point controlled by 1 no. 6A switch with indicator
2 light points controlled by 1 no. 6A switch with indicator.
3 light points controlled by 1 no. 6A switch with indicator
SWITCHES & SOCKETS
SIT & C of the following components like approved plate type modular switches, socket etc, duly wired. All the switch sockets are with front plate and without boxes since the same is covered under different item.
1 No. - 6/16A, 6 pin in universal socket controlled by 16A, SP switch , RP in workstations and in cabins, with MS/PVC Box.
Same as above but without MS/PVC Box
3 Nos - 6A, 3 pin socket controlled by common 16A, SP switch , workstations without MS/PVC Box
Same as above but with MS/PVC Box
LIGHT AND FAN FIXTURE WORK
INDOOR TYPE LUMINAIRE
Supply, installation, testing and commissioning of light fixture complete with all accessories, as required. Erection rate shall include necessary GI chain and supporting suspending hardware for fixing the light fittings.
Recessed mounted circular down lighter (Philips Cat No. DN195B LED 20S - 6500 PSU WH S1) or approved equivalent.
Dismantling
Dismantling of existing light fittings,switch boards, conduit, if any.
AC Sockets
Supply and flush fixing of modular type heavy duty plug socket unit comprising of 16/25A socket and plug top (with indicator) and solid state type starter units of electronic type with highflow voltage protections, O/L protect etc and suitable for 1.5/1.0 TR AC Units modular type and completely wired including cutting chases and mending good damages, painting, earthing, necessary connections complete, as per required for AC Units.
MCB Enclosure for AC
SITC of 6-32 Amps DP MCB (D-Curve) with metal enclosure (outdoor type-IP65)near AC ODU (concealed/surface)
Empty Conduits
Supply and fixing of FRLS PVC (ISI marked) conduit (rigid/flexible) of various dia, exposed or concealed with all accessories like tees, bends, glands etc. JBs (PVC) as required and fish wire etc for wiring purpose complete and mending good damages to building works.
20 mm dia (2 mm thick)
Supplying and fixing PVC casing-capping on wall or ceiling, including elobw, necessary PVC fittings etc. amd mending good damages to building works
20x10 mm Size
HI WALL SPLIT AC
Supply, Installation, Testing & commissioning of Hi-wall Split 1st charge R-32/R-410A gas BEE 3 STAR RATED non inverter type air-cooled split Air-conditioner with cordless remote, hermetic/semi hermetic rotary type compressor having with copper coil of IDU & ODU, 3 Mtrs. Copper pipe with Armaflex insulation and 25 mm hard drawn UPVC piping with Armaflex insulation for sweat water drain complete as per direction of Engineer-in-charge. Extra copper pipe line (Suction & Liquid) beyond 3 mtr. will be paid extra as per measurement.
1.5 tr - 3 star rated
1.0 tr - 3 star rated
REFRIGERANT PIPING
Supply and installation testing & commissioning of required size soft/hard drawn refrigerant piping for the 1.5/ 1.0 TR. High-wall split type A.C. Units including Nitryle Rubber Insullation.
DRAIN PIPING
Supplying and laying of condensate drain line with PVC pipe complete with all accessories with 6mm Nitryle Rubber Insulation .
CABLE
Supply & laying, dressing, clamping, testing and commissioning of 1.1 KV grade, stranded copper conductor, PVC insulated, extruded PVC inner sheathed, Galvanized wire/strip armoured and PVC outer sheathed LT control cable confirming to IS 1554 (Part-1) and of following size.
ODU STRUCTURE
Supplying and installation of powder coated ODU Angle for installation of Out door unit with all accessories including ribbed neoprene VI Pads , for Hi-wall splits & Cassettes AC machines
1.0 TR & 1.5 TR(Hi-wall Split AC)
Abdul Electricals and Infrastructures Pvt Ltd
The Suburban Electric Co.
Mukherjee Commercial Enterprise
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .