Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹17.0 L+₹3.0 L (21.5%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹17.5 L+₹3.5 L (24.6%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹17.7 L+₹3.7 L (26.5%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹18.0 L+₹4.0 L (28.4%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
25 May 2022, 6:00 pmClosed
MAJ JP SAHOO
GE 872 EWS, C/O 99 APO
REPAIRS/MAINT TO INTERNAL ELECTRIFICATION, REPAIRS/ MAINT/ SERVICING TO VARIOUS TYPES OF FANS AND GEYSER AND REPAIRS/ MAINT/ SERVICING TO COOLING APPLIENCES AT RAYANG MIL STN UNDER GE 872 EWS
2022_MES_521501_1
8418/T-18/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
RAYANG
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹30,000
Yes
30 May 2022
2 May 2022
26 May 2022
2 May 2022
25 May 2022
20 May 2022
2 May 2022 - 7 May 2022
Amount
REPAIRS & MAINT TO INTERNAL ELECTRIFICATIONS
M&L Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) complete from in any position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets (but excluding Light Fittings of any description), etc, Making Good Disturbed Surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 including providing Surface Treatment (Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Taking down/out unserviceable Sub-main Wiring from Batten/ Conduit/ PVC Casing Capping of any description, Making Good disturbed Portion/ Surfaces of Walls/ Floor/ Ceiling, etc. by using Cement Mortar 1:3 including providing Surface Treatment to match the Existing Treatment/ Finishes on Ground, complete all as specified and as directed.
M&L Taking down Unserviceable Service Connection Cable with Suspension Wire of any description from any Situation, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE BELL/BUZZER POINT controlled by One Bell Push Button Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire for ONE 6 AMP 3/5 PIN SOCKET OUTLET POINT on SAME BOARD, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 6 AMP, 3/5 PIN SOCKET POINT on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 6/16 AMP, 3/5 PIN SOCKET OUTLET POINT on INDEPENDENT BOARD, complete all as specified and all as directed.
M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :- (a) Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping will deem to be included in the Quoted Unit Rate and the same also Mesured as ONE UNIT. (b) Sub-main Wiring will be measured PVC Casing Capping only. Wire required for looping, etc. as ordered will deem to be included in the Quoted UNIT RATE.
M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :- (a) Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping will deem to be included in the Quoted Unit Rate and the same also Mesured as ONE UNIT. (b) Sub-main Wiring will be measured PVC Casing Capping only. Wire required for looping, etc. as ordered will deem to be included in the Quoted UNIT RATE.
S&F PVC Casing Capping (ISI Marked) of size 25mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed.
S&F PVC Casing Capping (ISI Marked) of size 32mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed.
S&F PVC Rectangular Block of size 175x100x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F PVC Rectangular Block of size 200x150x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Piano 16 Amp, Flush type, Single Pole, 1-way, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Bell Push, 6 Amp, Single Pole, Flush type, 230 Volt AC for operating Bell/ Buzzer and connecting up, complete all as specified and as directed.
S&F Socket Outlet 6 Amp, 3 Pin, 2-in-1, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Socket Outlet 16 Amp, 3 Pin, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 6 Amp, 3/5 Pin, 2-in-1, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 6/16 Amp, 5 Pin, Multi-Plug, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Socket Combination, complete all as specified and as directed.
S&F Lamp Holder PVC/ Polycarbonate type with Back Plate suitable for Batten/ Pandant Fitting and connecting up, complete all as specified and as directed.
S&F Ceiling Rose Surface type, Bakelite 65x50mm 2 to 3 Terminal suitable for 230 Volt AC, 6 Amp and connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator 230 Volt AC, Electronic, Rotary Stepped type, 230 Volt and connecting up, complete all as specified and as directed.
S&F Bell Ding Dong, 230 Volt AC, Single Pole and connecting up, complete all as specified and as directed.
S&F LED Bulb/ Lamp 9/ 10 Watt, 230 Volt, Self-ballasted and fixing to existing Light Fitting including Taking down/out Unserviceable Bulb/ Lamp, complete all as specified and as directed.
S&F LED Tube Light 18/20 Watt, 240 Volt and fixing to existing Light Fitting including Taking down/out Unserviceable Tube Light, complete all as specified and as directed.
S&F Decorative LED Light Fitting 1x9 Watt/ 1x10 Watt Bulkhead Luminaires including LED Light, Driver, Holder, connecting up with 3 Core Flexible Copper Conductor Cable of suitable size including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Light Fitting 10 Watt, Mirror type with High Out-put Diffuser 2 Feet, 220 Volt AC, Decorative type with Driver, Holder and LED Lamp, connecting up with 3 Core Flexible Copper Conductor Cable of suitable size including Taking down/ out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Round shape 12 Watt 220 Volts AC Recessed type with high efficiency PMMA Diffuser Soft Glare Free Light complete with Drivers, Holders, LED Lamp suitable for Roof Ceiling, connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Light Fitting 1x 18 Watt, 220 Volt, AC Decorative Box type with Driver, Holder, LED Tube Light and connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Luminaire 600x600 mm, 35/36 Watt, 220 Volt AC Recessed type with High efficiency PMMA Diffuser Soft Glare Free Light complete with Driver, Holders, LED Lamp suitable for Roof Ceiling, connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.
S&F Sheet Metal Enclosure, Single Pole & Neutral, 2 Pin & Earth Plug Top and Socket 20 Amp rating with and including 1 No. MCB 20 Amp, Single Pole and connecting up including Taking down/out Unserviceable Sheet Metal Enclosure, complete all as specified and as directed.
S&F MCB 6 to 32 Amp, Single Pole, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB 10 to 32 Amp, Single Pole & Neutral, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB 40 Amp, Triple Pole & Neutral, 'C' Series, 50 Hz, 10 kA, 415 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F Factory made Distribution Board Sheet Metal Enclosure, SPN, 4-way, 240 Volt, Single Door with Steel Phosphotised Powder Painted without Bus-Bars, fixed Flush with Wall Inside the Nitches or Outside on Wall Surface suitable for Mounting Isolators & MCB's etc. and connecting up including Taking down/out unserviceable DB, complete all as specified and as directed.
S&F Factory made Distribution Board Sheet Metal Enclosure, SPN, 8-way, 240 Volt, Single Door with Steel Phosphotised Powder Painted having 200 Amp rated Neutral Bars & Earth Bar, fixed Flush with Wall Inside the Nitches or Outside on Wall Surface suitable for Mounting Isolators & MCB's etc. and connecting up including Taking down/out unserviceable DB, complete all as specified and as directed.
S&F Factory made Vertical Distribution Board Sheet Metal Enclosure TPN, 4-way, 415 Volt, Double Doors, Front Openable with Steel Phosphotised Powder Painted, having 200 Amp rated Neutral Bars & Earth Bar, fixed Flush with Wall Inside the Nitches or Outside on Wall Surface suitable for Mounting Isolators & MCB's etc. and connecting up including Taking down/out unserviceable DB, complete all as specified and as directed.
S&F PVC insulated Aluminium Stranded Conductor Cable 10 Sqmm, 2 Core, 1100 Volts grade, Heavy duty, Flat or Circular served with Inner Sheathing of PVC Tape and Overall PVC sheathed in Service Connections suspended by Insulating Hangers not more than 1.0 Metre apart including 4.0mm Suspension Wire, complete all as specified and as directed.
S&F PVC insulated Aluminium Stranded Conductor Cable 16 Sqmm, 2 Core, 1100 Volts grade, Heavy duty, Flat or Circular served with Inner Sheathing of PVC Tape and Overall PVC sheathed in Service Connections suspended by Insulating Hangers not more than 1.0 Metre apart including 4.0mm Suspension Wire, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Old Unserviceable Earthing of any description, complete all as per specified and as directed.
REPAIRS & MAINT TO FANS
M&L Taking down unserviceable Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Air Circulator Fan of any Make & Size after disconnecting and removing to AGE E/M Store Yard at RAYANG for Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Re-hanging the same in Original Position after repaired and providing Electric Connection, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involved to make the Fan completely Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Rewinding & Other Parts required to be replaced will be Measured and Paid separately as "S&F"/"M&L" under relevant Items.
S&F Ball Bearing (size as per existing one/ as approved) for Ceiling Fan 1200/ 1400mm Sweep including Taking down/out unserviceable Ball Bearing, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
S&F Condenser 2.5 mfd for Ceiling Fan & Wall Mounted Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed. MAKE : AMCAP/ EPCOS/ HAVELLS
S&F Condenser 4.0 mfd for Exhaust Fan/ Air Circulator Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed. MAKE : AMCAP/ EPCOS/ HAVELLS
S&F Gun Metal Bush (size as per existing One/ as approved) suitable for Ceiling/Exhaust/Cabin Fan of any Make/Model and any Size including Taking down/out unserviceable Bush, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
S&F Mild Steel Down Rod 15mm nominal dia and 250mm to 450mm long, heavy duty, duly painted in matching Colour of Fan, necessary drilling, etc. for hanging of Ceiling Fan including Taking down/out unserviceable Down Rod, complete all as specified and as directed.
S&F Oscilating Mechanism for Wall Fan 400mm Sweep including Taking down/out unserviceable Oscilating Mechanism, complete all as specified and as directed.
S&F Rubber Bush (Reel type) Standard size and type duly fixed with suitable size Mild Steel Bolt, Nuts, etc. including Taking down/out unserviceable Rubber Bush, complete all as specified and as directed.
M&L Transporting Ceiling Fan 1200mm Sweep from AGE E/M Store Yard at RAYANG to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Ceiling Fan 1400mm Sweep from AGE E/M Store Yard at RAYANG to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Exhaust Fan 250/ 300/ 350mm Sweep from AGE E/M Store Yard at RAYANG to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Wall/ Cabin Fan 300/ 400mm Sweep from AGE E/M Store Yard at RAYANG to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
S&F PVC Stranded Copper Conductor Flexible Cable 1.5 Sqmm 3 Core for Electric Connection including Taking down unserviceable Cable, complete all as specified and as directed.
REPAIRS & MAINT TO GEYSERS
M&L Taking down/Lowering Defective Water Heater of any Capacity/ Make/ Type from any Height by disconnecting all Water and Electric Connections, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair Works involves, Repairing/ Replacing of unserviceable Accessories, Removing all Rusted Nuts, Bolts, de-scaling Inner Tank & Inter Connection Assembly, Cleaning thoroughly with Diluted Acid, Brazing/Gas welding of Inter Connection Assembly, Checking of Inner Tank to make Fully Leakeage Proof and Testing the same with Water Filling/Air Pressure, Re-fixing/ Re-mounting the same in Original Position and providing necessary Water/ Electric Connection and and Testing, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Water Heater(Geyser) completely Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Parts required to be replaced will be Measured and Paid separately as "S&F" under relevant Items and Quantities are Provisional.
S&F Heating Element 1.5 KW 230 Volt AC for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed. MAKE : BAJAJ/ DITZ/ POWER PACK/ THEETA
S&F Heating Element 2.0 KW 230 Volt AC for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed. MAKE : BAJAJ/ DITZ/ POWER PACK/ THEETA
S&F Indication Lamp Rounded type 230/240 Volt suitable for Water Heater (Geyser) of any Capacity/ Make/ Model and Testing including Taking down/out unserviceable Indication Lamp, complete all as specified and as directed.
S&F Pressure Release Valve Dead Weight type for Water Heater (Geyser) of any capacity, any Make including Taking down/out unserviceable Pressure Release Valve, complete all as specified and as directed.
S&F Thermostate Switch with Thermal Setting 40 °C to 90 °C Capacity and Relay 230 Volt including Taking down/out unserviceable Pressure Release Valve, complete all as specified and as directed.
S&F PVC Connection 15mm bore (dia) of length 450mm with PTMT Nuts suitable for Cold/Hot Water including Taking down/ out unserviceable PVC Connection, complete all as specified and as directed.
S&F PVC Pipe 15mm bore (dia), Heavy duty for Inlet and Outlet Connections suitable for Water Heater (Geyser) including Taking down/out unserviceable PVC Pipe, complete all as specified and as directed.
M&L Repairs to Water Heater of any capacity and type by Taking out Unservice-able Water Tank (Inner Shell), brazing to leaking Portion or Patching Work as required with using Copper Plate 1.5mm thick including shaping to Original size, complete all as specified and as directed.
M&L Minor Repairs to Leakage/ Cracked developed in Inner Copper Container of Water Heater of any Capacity, Type & Make by means of Brazing/ Soldering with Copper Brass Aalloy, Testing of Inner Shell up to the Entire Satisfaction of the Engineer-in-Charge, Re-assembling and Re-installed at Site, complete all as specified and as directed.
M&L Wall Fastener of size 100mm long, 8.0mm dia with Double Washers and Grouting to Walls, Making Good in Distrubed Portion of Walls in Cement Mortar 1:4 for Fixing Water Heater after including Taking out/ Removing the Unserviceable Bolts, Nuts & Washers, complete all as specified and as directed.
S&F Plug Top 15 Amp, 3 Pin, ISI marked and connecting up including Taking down/out unserviceable Plug Top, complete all as specified and as directed.
REPAIRS & MAINT TO AIR CONDITIONERS
M&L Taking down/ Lowering Defective Split AC 1.5/2.0 TR Capacity of any Make from any Height by disconnecting all Electric Connections, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects & Repair Works involves, Repairing/Replacing of unserviceable Parts, Cleaning thoroughly Condensing Unit to achive Proper Cooling effect, Checking of Electronic Circuit of Machine, Changing of Wiring with proper size PVC insulated Copper Wires, Brazing the Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof, Re-install the Same in Original/ New Position and providing necessary Electric Connection, Testing on Completion, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Split AC 1.5/2.0 TR Capacity Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items and the Quantities are Provisional.
M&L Compressor Rotary type (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split AC 1.5 TR Capacity with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : CARRIER/ HITACHI/ KIRLOSKAR/ TECUMSEH
M&L Compressor Rotary type (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split AC 2.0 TR Capacity with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : CARRIER/ HITACHI/ KIRLOSKAR/ TECUMSEH
M&L Condensor Fan Blade Assembly, Heavy duty for Fan Motor (as per existing One/ as approved) suitable for Split type AC 1.5/2.0 TR Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Condensor Fan Blade Assembly, complete all as specified and as directed. MAKE : CARRIER/ FEDDERS LLOYED/ VOLTAS
M&L Indoor Motor, Single Phase, 230 Volt (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split type AC 1.5/2.0 TR Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Condensor Fan Blade Assembly, complete all as specified and as directed. MAKE : AUE/ USHA or equivalent as approved by GE
M&L Outdoor Motor, Single Phase, 230 Volt (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split type AC 1.5/2.0 TR Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Condensor Fan Blade Assembly, complete all as specified and as directed. MAKE : AUE/ USHA or equivalent as approved by GE
M&L Power Circuit PVC Plate (as per Existing One/ as approved) suitable for Split type AC 1.5 TR and providing necessary Connections & Testing including Taking down/out unserviceable Power Circuit Plate, complete all as specified and as directed.
M&L Power Circuit PVC Plate (as per Existing One/ as approved) suitable for Split type AC 2.0 TR and providing necessary Connections & Testing including Taking down/out unserviceable Power Circuit Plate, complete all as specified and as directed.
M&L Repairs to Power Circuit (PC) Plate of Split type AC 1.5 TR, re-fixing after repaired and providing necessary Connections, complete all as specified and as directed.
M&L Repairs to Power Circuit (PC) Plate of Split type AC 2.0 TR, re-fixing after repaired and providing necessary Connections, complete all as specified and as directed.
M&L Sensor Set Dry Cool (as per Existing One/ as approved) suitable for Split type AC 1.5/2.0 TR and providing necessary Connections & Testing including Taking down/out unserviceable Sensor Set, complete all as specified and as directed.
M&L Copper Pipe 1/2" (as per Existing One/ as approved) to match the Same Model & Capacity AC with necessary Connection & Testing including Taking down/ out unserviceable Pipe, complete all as specified and as directed.
M&L Copper Pipe 5/8" and 3/8" (as per Existing One/ as approved) to match the Same Model & Capacity AC with necessary Connection& Testing including Taking down/ out unserviceable Pipe, complete all as specified and as directed.
M&L Flare Nut made out of Brass for Copper pipe 1/2"/ 3/8" (as per Existing One/ as approved) including Taking down/ out unserviceable Nut, complete all as specified and as directed.
M&L Insulation On & Around Suction and Discharge Copper Piping with 6.0mm thick Flexible Thermocool Heat Resistant duly scrapped with Sticking Tape & Testing including Taking down/ out unserviceable Insulation, complete all as specified and as directed.
Supply & Charging Gas F-22 to Split type Air Conditioner 2.0 TR Capacity including necessary Servicing, Brazing to Stop the Leakage of required Pressure & Testing, complete all as specified and as directed.
M&L Shifting Split type AC 1.5/2.0 TR Capacity Outer Unit with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage Vacum Test Pressure, Testing, insisting thick Flexible Thermocool and Servicing of Indoor and Outdoor Unit, complete all as specified and as directed.
M&L Dismantling Voltage Stablizer of capacity 3.0 KVA having Input Rating 135- 290 Volts including Transformer Copper wound, Relays Contact Point, Wiring with Replacement of Volt Meter, Repairs to Transformer, Replacement of Relays, Assembling the complete & Testing, complete all as specified and as directed.
M&L Dismantling Voltage Stablizer of capacity 5.0 KVA having Input Rating 135- 290 Volts including Transformer Copper wound, Relays Contact Point, Wiring with Replacement of Volt Meter, Repairs to Transformer, Replacement of Relays, Assembling the complete & Testing, complete all as specified and as directed.
REPAIRS & MAINT TO REFRIGERATORS
M&L Opening Defective Refrigerator of any Capacity/ Make/ Model/ Type, Removal of Blockage by Flushing Out, Brazing (as required) and Making the System Fully Leakeage Proof, Replacing unserviceable Compressor & Other Parts and Re-assembling after necessary repaired and Testing, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Refrigerator Functional, even if not notified by JE/ Engineer-in-Charge, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items and the Quantities are Provisional.
M&L Compressor Unit Hermetically Sealed (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : KIRLOSKER/ TECHUMSHEH/ WHIRLPOOL
M&L Compressor Unit Hermetically Sealed (as per Existing One/ as approved) suitable for Refrigerator 286/310 Litre Capacity, providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : KIRLOSKER/ TECHUMSHEH/ WHIRLPOOL
M&L Door Gasket, Magnetic type (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity including Taking down/ out unserviceable Door Gasket, complete all as specified and as complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
M&L Door Gasket, Magnetic type (as per Existing One/ as approved) suitable for Refrigerator 286/310 Litre Capacity including Taking down/ out unserviceable Door Gasket, complete all as specified and as complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
M&L Freeze Assembly Complete (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Freeze Assembly, complete all as specified and as directed.
M&L Freeze Assembly Complete (as per Existing One/ as approved) suitable for Refrigerator 286/310 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Freeze Assembly, complete all as specified and as directed.
M&L Over Load Protector 1/8 HP Capacity (as per Existing One/ as approved) suitable for Refrigerator of any Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Over Load Protector, complete all as specified and as directed. MAKE : HITECH/ RENUTRAL/ USHA
M&L Over Load Protector 1/6 HP Capacity (as per Existing One/ as approved) suitable for Refrigerator of any Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Over Load Protector, complete all as specified and as directed. MAKE : HITECH/ RENUTRAL/ USHA
M&L Pigmy Lamp 15 Watt, 230 Volt AC (as per Existing One/ as approved) suitable for Refrigerator of any Capacity & Testing including Taking down/ out unserviceable Lamp, complete all as specified and as directed. MAKE : CROMPTON/ PHILIPS
M&L Power Circuit (PC) Breaker (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Power Circuit (PC) Plate, complete all as specified and as directed.
M&L Power Circuit (PC) Breaker (as per Existing One/ as approved) suitable for Refrigerator 286/310 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Power Circuit (PC) Plate, complete all as specified and as directed.
M&L Relay Open type, 1/8 HP (as per Existing One/ as approved) suitable for Refrigerator of any Capacity & Testing including Taking down/ out unserviceable Relay, complete all as specified and as directed. MAKE : HITECH/ RENUTRAL/ USHA
M&L Relay Open type, 1/6 HP (as per Existing One/ as approved) suitable for Refrigerator of any Capacity & Testing including Taking down/ out unserviceable Relay, complete all as specified and as directed. MAKE : HITECH/ RENUTRAL/ USHA
M&L PVC/Plastic Chilled Freezer Tray Complete (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity including Taking down/ out unserviceable Chilled Freezer Tray, complete all as specified and as complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
M&L PVC/Plastic Chilled Freezer Tray Complete (as per Existing One/ as approved) suitable for Refrigerator 286/ 310 Litre Capacity including Taking down/ out unserviceable Chilled Freezer Tray, complete all as specified and as complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
M&L PVC/ Plastic Ice Tray, Superior quality of Large size with PVC Separator Complete (as per Existing One/ as approved) suitable for Refrigerator of any Capacity, Providing necessary Connections including Taking down/ out unserviceable Ice Tray, complete all as specified and as directed.
M&L PVC/ Plastic Vegetable Tray Complete (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity including Taking down/ out unserviceable Vegetable Tray, complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
M&L PVC/ Plastic Vegetable Tray Complete (as per Existing One/ as approved) suitable for Refrigerator 286/ 310 Litre Capacity including Taking down/ out unserviceable Vegetable Tray, complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
Supply & Charging of Refrigerant F-22 to Refrigerator of any Capacity/ Make/ Model/ Type after Cleaning of Condenser Unit, Evoporator Unit, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof and Vaccuming and Testing, complete all as specified and as directed.
REPAIRS & MAINT TO WATER COOLER & DEEP FREEZER
M&L Opening Defective Water Cooler of any Capacity/ Make/ Model/ Type for Checking/ Repairing, Removal of Blockage by Flushing Out, Brazing (as required) Suction & Discharge Pipes for Making the System Fully Leakeage Proof, Cleaning thoroughly Cooling Coil to achive Proper Cooling effect, Replacing unserviceable Compressor & Other Parts and Re-assembling after necessary repaired & Testing, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Water Cooler Functional, even if not notified by JE/ Engineer-in-Charge, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items and the Quantities are Provisional.
M&L Capacitor 10 mfd Capacity suitable for Water Cooler 40/80 Litre or 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Capacitor, complete all as specified and as directed. MAKE : ASAIN/ KEL/ SPEED/ UNISTAR
M&L Compressor Unit Hermetically Sealed (as per Existing One/ as approved), Single Phase suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : KIRLOSKAR/ SHRIRAM/ TECHEMSHAH
M&L Compressor Unit Hermetically Sealed (as per Existing One/ as approved), Single Phase suitable for Water Cooler 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : KIRLOSKAR/ SHRIRAM/ TECHEMSHAH
M&L Fan Blade Assembly Complete, Heavy duty (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Fan Blade Assembly, complete all as specified and as directed. MAKE : SIDHWAL/ USHA/ VOLTAS
M&L Fan Motor 1/35 HP or 1/32 HP Capacity (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Fan Motor, complete all as specified and as directed. MAKE : AUE/ CROMPTON
M&L Over Load Protector 2613 (as per Existing One/ as approved) suitable for Water Cooler of any Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Over Load Protector, complete all as specified and as directed. MAKE : HITACHI/ TECHEMSHAH
M&L Starting Capacitor 40/60 mfd suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Starting Capacitor, complete all as specified and as directed. MAKE : ASAIN/ EPCOS/ SPEED/ UNISTAR
M&L Starting Capacitor 80/100 mfd suitable for Water Cooler 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Starting Capacitor, complete all as specified and as directed. MAKE : ASAIN/ EPCOS/ SPEED/ UNISTAR
M&L Starting Kit comprising of Relay & Over Load Protector (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Starting Kit, complete all as specified and as directed. MAKE : RENUTRAL/ SHRIRAM
M&L Thermostatic Switch (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Thermostatic Switch, complete all as specified and as directed. MAKE : GODREJ/ INDOFOSS/ RENUTRAL
M&L Push Cock 15mm bore (dia) Brass Chromium plated, high pressure, screwed down for Socket/ Unions or GI Pipe including Taking down/ out unserviceable Push Cock, complete all as specified and as directed. MAKE : JAINSON/ NIXON or equivalent as approved by GE
M&L PVC Drain Pipe 32mm bore (dia), Heavy duty of Length 1.00 Metre with 2 Nno. Galvanized Adjustable Clamps, Providing necessary Connections including Taking down/ out unserviceable Drain Pipe, complete all as specified and as directed.
M&L PVC Float Valve Assembly 15mm bore (dia) comprising Valve Assembly, Aluminum Rod, PVC Ball, suitable Water Cooler/ Desert Cooler including Taking down/ out unserviceable Float Valve Assembly, complete all as specified and as directed.
M&L Denting, Welding to Water Cooler 40/80 Litre Capacity including applying Two Coats of Synthetic Enameled Paint (1st quality/ grade) over a Coat of red Oxide Zinc Chrome Primer with Spray Painting Machine after necessary Preparation of Surfaces including Sencil Writing MES No. with Paint, complete all as specified and as directed.
Supply & Charging Gas F-12 to Water Cooler 40/80 Litre Capacity including necessary Servicing, Brazing to Stop the Leakage of required Pressure and Testing, complete all as specified and as directed.
Supply & Charging of Refrigerant F-22 to Deep Freezer 320 Litre Capacity of any Make/ Type after Cleaning of Condenser Unit, Evoporator Unit, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof and Vaccuming and Testing, complete all as specified and as directed.
M&L PVC insulated, Sheathed Copper Conductor multi-stranded Cable of size 40/.0076, 3 Core (Colour White or Black) and Providing Electric Connection including Taking down/out unserviceable Cable of any description, complete all as specified and as directed.
STANDARD ELECTRIC WINDERS
FREEZCON
NChetia and Sons Trading
MAZUMDAR ENTERPRISE
Bimal Trading Company
boruah construction
M/s. R. K. Trading Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .