| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC D NO 5 13 24 1 BEHIND SAHUWALA CYLINDERS IDA AUTONAGAR VISAKHAPATNAM 530 012 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹1.5 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹1.9 Cr+₹42.5 L (28.1%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | ₹1.9 Cr+₹42.5 L (28.1%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹2.1 Cr+₹59.5 L (39.4%)Rejected-Finance | ₹2.1 Cr+₹59.5 L (39.4%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹2.2 Cr+₹66.0 L (43.8%)Rejected-Finance H NO 9 9 1 1 DOCTOR S COLONY SHIVAJIPALEM VISAKHAPATNAM 530 017 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530017 | ₹2.2 Cr+₹66.0 L (43.8%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹2.7 Cr+₹1.2 Cr (81.6%)Rejected-Finance | ₹2.7 Cr+₹1.2 Cr (81.6%) | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹5.3 L
Closing Date
5 Jul 2021, 6:00 pmClosed
CHIEF ENGINEER COAST GUARD VISAKHAPATNAM
OFFICE OF CHIEF ENGINEER COAST GUARD VISAKHAPATNAM MILITARY ENGINEER SERVICES D NO 39 4 2 2 PLOT NO 18 NEAR VARMA COMPLEX MURALINAGAR VISAKHAPATNAM 530 007
PROVISION OF LIFTS FOR BALANCE MARRIED ACCN AT CGDHQ-6 VISAKHAPATNAM
2021_MES_413818_1
C. A. No. CE (CG)/VIZ/TOKEN/16 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
547 days
VISAKHAPATNAM
As per tender documents
8 documents required · 8 mandatory
₹2,000
Yes
AGE (I) (CG) VIZAG
₹5.3 L
Yes
27 Aug 2021
18 Jan 2021
7 Jul 2021
18 Jan 2021
5 Jul 2021
30 Jun 2021
Amount
(a) TECHNICAL SPECIFICATIONS (i) Type & Capacity : Passenger elevator for 08 persons (544Kg). (ii) Type of drive: Variable voltage and variable frequency drive with microprocessor based controller + 5 mm landing accuracy with speed encoder. (iii) Speed: 1.5 meter per second. (iv) Travel: Suitable for passenger travel of Approx 55 meters, (opening on same side). (v) Existing well size: 2300 mm x 2300 mm deep (over plaster) (approx) without any projected beam/column. (vi) Power supply: 03 Phase, 415 V, 50Hz (should withstand variation of + 5%). (vii) Inner size: Car size shall be in confirmity to IS : 14665. (viii) Car enclosure: Car shall be with SS false ceiling (hairline finish), stainless steel body of 16 gauge with moon rock finish and stainless steel hand rail of suitable dia and size with hair line finish. (ix) Main drive and control shall be latest, high efficient and low power consumption. (x) Flooring: Polished granite flooring. (xi) Electric light: 04 Nos circular LED recessed on false ceiling shall be provided. (xii) Fan: Cross flow fan – 01 No. (xiii) Car entrance: Automatic, centre opening, sliding doors.
(xiv) Clear opening: Not less than 800mm x 2000mm high. (xv) Operation door: Automatic operation with stainless steel frame front opening landing door of toughened glass not less than 12mm thick. (xvi) Control: Simplex full collective with and without attendant. (xvii) Indicators: Hall position indicators for car & landing direction and position indicator with stainless steel fixtures at all floors.
(b) STANDARD FEATURES (i) Anti nuisance car call protection. (ii) Automatic car return device (home landing). (iii) Independent service (for duplex only). (iv) Overloading device with tripping system, including warning indicator both audio and visual types. (v) Nudging buzzer if door is held open for more than 30 sec.. (vi) Emergency fireman’s service. (vii) Audible car call button. (viii) Emergency car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time protection. (xi) Emergency alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation. (xv) Belt inspection device. (xvi) Indoor communication to be connected with nearest security post. (xvii) Battery operated emergency light (LED ceiling fittings/ alarm/ speakers for emergency alarm system) and stop button in the car. Battery should have arrangements for recharge. (xviii) Other standard fixtures and fittings like guide rails, sheaves , counter weights with guards, buffers , gear units, brakes control panel, lock governor, car operation panel, power control and trailing cables complete.
(xix) Steel wire rope of adequate size as per relevant IS and as per manufacturer's specifications. (xx) Suitable phase reverse relay shall be provided to the controller to protect lift against phase reversal, phase failure and low voltage. (xxi) Set of three limit switches at the bottom and top most position of lift hoist ways as specified in IS. (c) ADDITIONAL FEATURES (i) Automatic rescue device. During power failure and manual operation suitable provision shall be provided to run the lift with full load to the nearest floor.
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with full light 16-segment display panel , digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) . (iii) Door open/Door closed on car operating panel. (iv) 2-way intercommunication system. (v) Monochrome LED digital position indicator display. (vi) Fireman’s switch at main lobby. (vii) Manual rescue operation. (viii) Call register indicator in all landings. (ix) Attendant operation system in car panel.
(a) TECHNICAL SPECIFICATIONS (i) Type & Capacity : Passenger elevator for 13 persons (884Kg). (ii) Type of drive: Variable voltage and variable frequency drive with microprocessor based controller + 5 mm landing accuracy with speed encoder. (iii) Speed: 1.5 meter per second. (iv) Travel: Suitable for passenger travel of Approx 55 meters, (opening on same side). (v) Existing well size: 2300 mm x 2300 mm deep (over plaster) (approx) without any projected beam/column. (vi) Power supply: 03 Phase, 415 V, 50Hz (should withstand variation of + 5%). (vii) Inner size: Car size shall be in confirmity to IS : 14665. (viii) Car enclosure: Car shall be with SS false ceiling (hairline finish), stainless steel body of 16 gauge with moon rock finish and stainless steel hand rail of suitable dia and size with hair line finish. (ix) Main drive and control shall be latest, high efficient and low power consumption. (x) Flooring: Polished granite flooring. (xi) Electric light: 04 Nos circular LED recessed on false ceiling shall be provided. (xii) Fan: Cross flow fan – 01 No. (xiii) Car entrance: Automatic, centre opening, sliding doors.
(xiv) Clear opening: Not less than 800mm x 2000mm high. (xv) Operation door: Automatic operation with stainless steel frame front opening landing door of toughened glass not less than 12mm thick. (xvi) Control: Simplex full collective with and without attendant. (xvii) Indicators: Hall position indicators for car & landing direction and position indicator with stainless steel fixtures at all floors.
(b) STANDARD FEATURES (i) Anti nuisance car call protection. (ii) Automatic car return device (home landing). (iii) Independent service (for duplex only). (iv) Overloading device with tripping system, including warning indicator both audio and visual types. (v) Nudging buzzer if door is held open for more than 30 sec.. (vi) Emergency fireman’s service. (vii) Audible car call button. (viii) Emergency car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time protection. (xi) Emergency alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation. (xv) Belt inspection device. (xvi) Indoor communication to be connected with nearest security post. (xvii) Battery operated emergency light (LED ceiling fittings/ alarm/ speakers for emergency alarm system) and stop button in the car. Battery should have arrangements for recharge. (xviii) Other standard fixtures and fittings like guide rails, sheaves , counter weights with guards, buffers , gear units, brakes control panel, lock governor, car operation panel, power control and trailing cables complete.
(xix) Steel wire rope of adequate size as per relevant IS and as per manufacturer's specifications. (xx) Suitable phase reverse relay shall be provided to the controller to protect lift against phase reversal, phase failure and low voltage. (xxi) Set of three limit switches at the bottom and top most position of lift hoist ways as specified in IS. (c) ADDITIONAL FEATURES (i) Automatic rescue device. During power failure and manual operation suitable provision shall be provided to run the lift with full load to the nearest floor.
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with full light 16-segment display panel , digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) . (iii) Door open/Door closed on car operating panel. (iv) 2-way intercommunication system. (v) Monochrome LED digital position indicator display. (vi) Fireman’s switch at main lobby. (vii) Manual rescue operation. (viii) Call register indicator in all landings. (ix) Attendant operation system in car panel.
NOTES FOR ITEM No 1 & 2 : (i) Contractor should keep the lift functional by repairing/replacing [as decided by AGE(I)] the components during the defects liability period. (ii) Work should be completed in 02 PHASES as mentioned in Schedule 'A' Notes.
Escon Elevators Pvt Ltd
M/S N.K BUILDERS
SERVO-TECH ENTERPRISES
Air Perfection
Omega Elevators
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .