Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹46.6 L+₹4.3 L (10.0%)Rejected-Finance REVATHY TC 79 1020 3 SREE RAGAM ROAD KARIKKAKOM KARIKKAKOM PO THIRUVANANTHAPURAM 695021 | THIRUVANANTHAPURAM | KERALA | 695021 | L2 | Rejected-Finance unsuccessful bidder | |
| 3 | L3₹48.5 L+₹6.2 L (14.6%)Rejected-Finance | L3 | Rejected-Finance unsuccessful bidder | |
| 4 | L4₹49.9 L+₹7.5 L (17.7%)Rejected-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L4 | Rejected-Finance unsuccessful bidder | |
| 5 | L5₹50.0 L+₹7.6 L (18.0%)Rejected-Finance | L5 | Rejected-Finance unsuccessful bidder |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
15 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Trivandrum
Office of Garrison Engineer AF, Pulayanarkotta, Thuruvikkal Post, Trivandrum-11
REPAIR/REPLACEMENT OF MANGALORE TILES AND WATER PROOF TREATMENT TO CERTAIN BUILDINGS AT HQ SAC UNDER GE AF TRIVANDRUM
2024_MES_638014_1
8478
Open Tender
Civil Works
Works
270 days
Trivandrum
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF Trivandrum
₹85,000
Yes
6 Apr 2024
18 Jan 2024
17 Feb 2024
18 Jan 2024
15 Feb 2024
3 Feb 2024
Amount
Dismantling single layer mangalore pattern or similar tiles in roofing incl ridge tiles complete all as specified and directed.
Taking down cement plaster including existing roof treatment or fillets on roof surfaces and wall surfaces complete, racking out joints, hacking for key scrubbing down with water etc. and removing rubbish to a distance exc 250m and not exc 500m all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. and brushing neat cement slurry @ 3kg / sqm complete all as specified and directed.
Demolition of RCC as in existing water tank wall on roof (other than ground floors) complete all as specified and directed.
Demolition of cement concrete in roofs, floors(other than ground floor), beams, staircases, landing and similar suspended work, complete all as specified and as directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair surfaces of brick masonry or concrete surface, finished the surface even and smooth with using extra cement incl using WPC as per manufacturers instructions, complete all as specified and directed. Note : WPC shall be measured and paid separately.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair surfaces of brick masonry or concrete surface, parapet wall, finished the surface even and smooth with out using extra cement complete all as specified and directed.
Supply only liquid waterproofing compound (ISI grade only)
M&L PCC 1:3:6 type C1 (20mm graded aggregate) Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in CM 1:6, complete sides all as specified
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in water tank platform on roof top portion finished even and smooth including necessary formwork etc. Complete.
M&L PCC 1:2:4 type Bo using 12.5mm graded stone aggregate as in padding concrete for roof, plinth courses, string courses, water troughs and the like finished even and smooth including necessary formwork, weathering, slightly rounded or chamfered angles and throating complete all as directed.
M&L for water proofing treatment on horizontal or vertical surface with provision of oil bound bitumen primer @ 0.20kg per sqm and applying a coat blown grade hot bitumen 85/25 or 90/15 @ 1.20 kg/sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4 kg/sqm, reinforced with non woven polyester matt weighing not less than 160 gm/sqm as per detailed specification and finished with solar reflective bituminous aluminium paint @ 100 gm per sqm all as specified and as directed.
M&L for preparation of newly plastered surface and applying two coats of weather coat Apex over a coat of alkali resistance priming paint complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, Cleaning and removing all scale and dirt, etc., from tanks and from mouths of circulating pipes etc. exc 250 & n exc 500 capacity in litres
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, Cleaning and removing all scale and dirt, etc., from tanks and from mouths of circulating pipes etc. exc 500 & n exc 1000 capacity in litres.
Dismantling water tanks exc 250 and not exc 500 Litre capacity
Dismantling water tanks exc 500 and not exc 1000 Litre capacity
S&F rotational moulded polythene water storage tank (Cylindrical vertical with close top) hoisted and fixed in position all as specified 250 litres capacity
S&F rotational moulded polythene water storage tank (Cylindrical vertical with close top) hoisted and fixed in position all as specified 500 litres capacity
S&F rotational moulded polythene water storage tank (Cylindrical vertical with close top) hoisted and fixed in position all as specified 1000 litres capacity
S&F in repairs 25mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Taking up or down 25 - 32mm bore pipe steel/ UPVC tubing and connections , including cleaning for re-fixing or removal from store complete all as specified and directed.
Refixing old 25- 32mm bore pipe UPVC pipe and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed.
S&F Unplasticised PVC 32mm bore pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe, complete all as specified and directed by Engr-in-Charge.
Dismantling of cast iron or reinforced concrete/ PVC drain pipes, any size jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, ceilings or in floors etc. and including necessary fittings PVC bends etc. also scaffolding where is required, complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls, ceilings or in floors etc. and including necessary fittings PVC bends etc. also scaffolding where is required, complete all as specified and directed.
S&F in repairs 32mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron/ UPVC pipe and fixed, complete all as specified and directed.
S&F in repairs 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron/ UPVC pipe and fixed, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks staging, angle iron trays for laying water pipes and similar work conforming to e.290.Gde-E-165
M&L for preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide primer.
M&L for Double scaffolding (without disturbing the existing wall) for removing the Mangalore pattern tiles on roof/ parapet and chajjas and for plastering and finishing work at the outer periphery of the building, complete all as specified and directed. Note:- (i) The buildings considered in this item is G+4 storey and above. (ii) Scaffolding measured only one time and one face for particular place after completion of work in all respect (like dismantling, plastering, painting and complete finishes work)
Taking up or down steel tubing and connections of following sizes including cleaning for refixing or removal to store complete all as specified and directed. Note: Excavation and earth work shall be measured and paid separately
20 mm dia bore
25 mm to 32 mm dia bore
40 mm to 50mm dia bore
80 mm dia bore
Relaying of GI Pipe line of following size dia bore retrieved from ser item No 34 above with all accessories :-
20 mm dia bore
25 mm dia bore
50 mm dia bore
80 mm dia bore
Supply and laying and testing of medium grade galvanised iron steel tubing of following sizes, ISI marked, including GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tees, checknuts, caps, plugs etc. complete laid in trenches/floors etc. complete all as specified and directed.
20 mm dia bore
25 mm dia bore
50 mm dia bore
80 mm dia bore
Taking up or down PP-R pipe and connections of 40 mm dia bore including cleaning for refixing or removal to store complete all as specified and directed. Note: Excavation and earth work shall be measured and paid separately
Relaying of PP-R pipe 40 mm dia in good condition retrieved from ser No 37.00 above with all accessories complete all as specified and directed.
Supply and fix 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed for 40 mm dia bore complete to walls, ceilings or in floors complete all as specified and directed
Dismantling of PP-R gate valve of size 40 mm including replacement of connections
Refixing of serviceable PP-R gate valve retrieved from ser No 40 above with all accessories
Supply and fix PP-R Gate valves (brass insert) of 40 mm dia bore size
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5 cm but not exceeding 10 cm and dia of neck 5 to 10mm complete all as specified and directed.
Dismantling old Gunmetal globe or gate valve, kept aside serviceable valve for refixing complete all as specified and directed for the following sizes
20 mm dia bore
25 mm dia bore
32 mm dia bore
40 mm dia bore
50 mm dia bore
Relaying of serviceable Gunmetal Gate valve retrieved against ser item No 44 above
20 mm dia bore
25 mm dia bore
32 mm dia bore
40 mm dia bore
50 mm dia bore
S & F Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe of following size of bore and conforming to IS 778 of 1984 complete all as specified and directed.
20 mm dia bore
25 mm dia bore
32 mm dia bore
40 mm dia bore
50 mm dia bore
S & F in repairs CI sluice valves 80 mm dia bore, flanged, heavy duty, class PN 1.0, as per IS-14856 including brass spindle, with hand wheel, nuts bolts and gaskets complete all as specified and directed.
Dismantling old Non return valve of following size, including cleaning serviceable valve for refixing complete all as specified.
25 mm dia bore
32 mm dia bore
50 mm dia bore
80 mm dia bore
Re fixing serviceable Non return valve retrieved against seritem No 48 above complete all as directed.
25 mm dia bore
32 mm dia bore
50 mm dia bore
80 mm dia bore
S & F Non return (Reflux) Valve, cast iron, of following size of bore, flanged, with GM working parts as per IS - 5312, with nuts bolts and gaskets complete suitable for GI/CPVC/UPVC as per site requirement all as specified and directed.
25 mm dia bore
32 mm dia bore
50 mm dia bore
80 mm dia bore
Supply and laying Hot water pipe (CPVC) duly insulated with glass wool and aluminium cladding for following size bore with suitable clamp on wall/ pipe tray including dismantling the existing hot water pipe line including all type fittings complete all as directed.
25 mm dia bore
32 mm dia bore
Dismantling UPVC pipe and fittings of following sizes, clean the serviceable pipe for relaying complete all as directed
20 mm dia bore
25 mm dia bore
32 mm dia bore
40 mm dia bore
Relaying serviceable Unplasticised PVC pipes retrieved from ser Item No 52 with all fittings and fixtures
20 mm dia bore
25 mm dia bore
32 mm dia bore
40 mm dia bore
Supplying and laying of Unplasticised PVC pipes with pressure rating 10 Kg/ Sqcm with all fittings, fixed complete to wall/floor/pipe tray with proper clamp complete all as specified.
20 mm dia bore
25 mm dia bore
32 mm dia bore
40 mm dia bore
Dismantling GI/Al strip of any sizes and thickness kept safe custody for re use all as directed. Note: Necessary T&P with safety eqpt shall be provided by the contractor for working in multistorey building and no extra payment will be made in this regard.
Relaying of serviceable GI/A strip of size any sizes and thickness retrieved from ser Item No 55 above with proper jointing complete all as specified and directed.
Supply and fix Aluminium strip 25 x 3.15mm thick as earthling lead fixed to wall/roof etc. complete all as specified and directed.
S & F epoxy base insulators of suitable size 40 mm height for fixing earth strip on wall/ceiling /floor etc. including dismantling old insulators complete all as specified.
Dismantling solar storage tank suitable for 100 litre capacity, including dismantling all pipe connection, electrical connection and frame of tank, kept safe custody and refixing after completion of work with suitable size of copper cable from DB to solar system in existing conduit and make the system serviceable after cleaning and servicing of storage tank, suitable pipe line with accessories complete all as specified and directed.
Dismantling solar plate collector with 4mm thick glass, frame made of aluminium section complete panel including enclosure and frame without damaging parts, kept in safe custody and refixing properly after cleaning / descaling & completion of work complete all as specified and directed.
DEFT GROUP ELECTROMECHANICAL
GRAND COOL SOLUTIONS
JEETH CONSTRUCTION
General Engineering and Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .