Executive Engineer PD PWD Dehradun
Office of Executive Engineer PD PWD Dehradun
Under the State Sector, surface coating and signage work of various roads of Ward No. 05 Dhorankhas in Mussoorie Assembly Constituency of Dehradun District by DBM/BC. (Remaining work through debitable agency)
2026_pwd_96106_1
1560/Nivida Dt. 23.05.2026
Open Tender
Civil Works
Dehradun
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
Executive Engineer
₹2.3 L
30 May 2026
30 May 2026
15 Jun 2026
1 Jun 2026
15 Jun 2026
2 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction | 627.93 | Cum | - | - |
| 2 | Dismantling of Structures
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Mechanical Means Cement Concrete | 0.74 | Cum | - | - |
| 3 | Disposel of excavated materials from site ahead Nagar Nigam area as per direction of E/I | 750.2 | Cum | - | - |
| 4 | Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203 | 173.54 | Cum | - | - |
| 5 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix (1:2:4) | 434.94 | Cum | - | - |
| 6 | Providing and laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80mm over 3mm layer of sand as per drawings and Technical Specifications. | 360 | Sqm | - | - |
| 7 | Providing and laying of Hot Thermoplastic compound of ISI Mark Approved Quality of 2.5mm thick including reflectorising glass beads @250 gms pe Sqm area as per IRC : 35. | 1,519.85 | Sqm | - | - |
| 8 | Road Delineators
Providing and fixing of Standard Metal Delineator consisting of minimum retro reflectiveunit exposed area of 330 sqcm, full cube corner micro prismatic non-metallic retro reflective sheeting on each side conforming with IRC 67 and meeting the coefficient of retro reflection values as per ASTM D 4956 Type XI table specification with pure polyester powder coating with the minimum thickness of powder coating of not less than 40 micron. The posts shall have ellipsoidal or circular design with the height of the poleshall be 800 to 900 mm above the ground with about 200 to 300 anchored with PCC M- 15 onto the ground. The front and back faces of the delineator should be curved with a radius of not more than 200 mm and with delta angle (or central angle of curve) lyingbetween 20o and 30 o, to increase the visibility of the delineator for vehicles moving in continuous curves. The delineator shall have sufficient arrangement to make the reflective sheets vandal-proof. Including all test report and warranties as per IRC 67 and IRC 79. | 227 | No. | - | - |
| 9 | AFP (Aluminum-backed flexible prismatic sheeting) Hazard Marker:
Providing and fixing Aluminum-backed flexible prismatic sheeting consisting of Yellow colored flexible prismatic sheeting with non-metallic prismatic lens as retro reflective elements and conforming to ASTM D 4956-09 Type VI specification values for reboundable sheeting. AFP sheeting shall be of 1ft width and laminated at the back with a 50 micron thick Aluminum (Al) foil with pressure sensitive adhesive and liner. AFP sheeting shall have screen printed arrow/slant line pattern in black color on top & shall not crack when tested for flexibility as per section S2.2.2 of ASTM D 4956-09. The AFP sheeting shall be applied with a neoprene contact adhesive with Polychloroprene as base & the edges of the product shall be sealed all around with a two-part epoxy based structural adhesive and shall be extremely resistant to peel-off & product specification shall confirm to IRC Accreditation. | 15.12 | Sqm | - | - |
| 10 | Direction and Place Identification Signs upto 0.9 sqm Size Board. Providing and erecting direction and place identification sign with corrosion resistant 2mm thick DG Grade Type XI retro- reflective cautionary, mandatory, informatory sign board with 10 year warranty as per IRC:67 made of high intensity sheeting fixed over ACP (Aluminium Composite Panel) 3 mm thick (including framing and bracing with fabrication, plotting of letters on Electro cut film, pasting, riveting, taping and nut, bolts, washers and rivets etc for fixing), with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing. (Clause No. 801 of MORTH) | 13.2 | Sqm | - | - |