| 1 | L1₹29.4 LAccepted-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹36.7 L+₹7.3 L (24.8%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹37.7 L+₹8.3 L (28.1%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹42.1 L+₹12.7 L (43.0%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 Apr 2025, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
REPAIR/MAINT OF DG SET, PUMPS STABILIZER LT PANEL, CABLES AND WATER SUPPLY ITEMS AT AF STN AMBALA UNDER GE (AF) AMBALA
2025_MES_703320_1
GE AF/AMB-T-45/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹98,000
Yes
26 Jun 2025
2 Apr 2025
2 May 2025
2 Apr 2025
30 Apr 2025
16 Apr 2025
Amount
Servicing of DG set of Cap 30 to 40KVA by checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect, inspection/testing of engine and alternator for smooth functioning of the DG set and including the replacement of following :- (i) fuel/ lub filter one set (ii) coolent in radiator (iii) Testing of engine control panel (iv) Cleaning of radiator, minor repair of leakages to be rectified. (v) hose pipe set (vi) fuel pipe/lubricant pipe (vii) Engine oil.
Servicing of DG set of Cap 62.5 to 100 KVA by checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect, inspection/testing of engine and alternator for smooth functioning of the DG set and including the replacement of following :- (i) service kit for elements of fuel/air/lub filter one set (ii) top up of coolent in radiator (iii) Testing of engine control panel (iv) Cleaning of radiator, minor repair of leakages to be rectified. (v) hose pipe set (vi) fuel pipe/lubricant pipe (vii) Engine oil.
Supply only following spare parts of DG set of kirloskar/Cummins DG set complete all as specified and directed:
V belt
Battery Terminal
Automatic Voltage Regulator for 30 to 40KVA DG set (Solid state voltage regulator type) complete all as specified and directed
Automatic Voltage Regulator for 62.5 to 100KVA DG set, complete all as specified and directed
Battery lead 1 mtr long (Red for +ve, & Black for -ve), complete all as specified and directed
Battery 120AH, maintenance free 12 volts, complete all as specified and directed
Charging alternator 12V/35A (DC) for 30 to 40KVA, complete all as specified and directed
Selfstarter Motor 12V (DC) for 30 to 100KVA, complete all as specified and directed
Charging alternator 12V/35A (DC) for 62.5 to 100KVA.
Selfstarter Motor 12V (DC) for 62.5 to 100KVA, complete all as specified and directed
Microprocessor based Genset controller, complete all as specified and directed
Distilled Water for batteries, complete all as specified and directed
M&L for applying two coat of epoxy paint by spray painting m/c on site,including preparation of rusted surface of DG Set, acoustic enclosure of 30/62.5/63/82.5/100 KVA and writing SM No./MES No.complete all as specified and as directed.
S&F in repairs changeover switch, on/off load, 4 Pole, 125Amps capacity, fixed in existing panel board complete all as specified and directed
S&F in repairs changeover switch, on/off load, 4 Pole, 160Amps capacity, fixed in existing panel board complete all as specified and directed
S&F in repairs changeover switch, on/off load, 4 Pole, 200Amps capacity, fixed in existing panel board complete all as specified and directed
S&F in repairs Motor Protection Circuit Breaker (MPCB), 3 pole, 415 volts, 25/34 KW, 50 KA breaking capacity with instantaneous trip-rotary type complete all as specified and directed
S&F in repairs MCCB, 4 pole, 415 volts, 125 Amps, 25KA breaking capacity with adjustable thermal settings and adjustable magnetic settings complete all as specified and directed
S&F in repairs MCCB, 4 pole, 415 volts, 160Amps, 25KA breaking capacity with adjustable thermal settings and adjustable magnetic settings complete all as specified and directed
S&F in repairs MCCB, 4 pole, 415 volts, 200Amps, 25KA breaking capacity with adjustable thermal settings and adjustable magnetic settings complete all as specified and directed
M&L for preparation of old painted surfaces steel by brushing, greasy spots with thinner and apply two coats of spray painting with super enameled grey colour paint of approved and writing the MES /SM No with white paint Servo Voltage Stabilizer. indoor/outdoor installed at various different locations complete all as specified and directed at site.
Disconnecting the LT incoming and outgoing main cables of any size, opening of the voltage stablizer capacity of 3 x 20KVA , draining out the oil into a cleaned container ( container shall be arranaged by the contractor ). Lifting up dimmer and transformer with help of tripoid and chain pulley etc (The T & P shall be arranged by contractor ), checking of all the parts ,cleaning and servicing of the inner surface of the voltage stabilizer, dimmer, transformers coil and allied parts including replacememnt of minor parts like nut bolts ,connecting wires ,rubber seals /packing etc. and reassembling the stablizer complete (in reverse order). Refilling oil after dehydration and filtration by centrifuging machine including testing of samples before and after dehydrations and filtration complete, reconnecting the supply complete all as specified and directed. Note: (i) The cost of Major parts repair or replacement will be measured and paid separately. (ii) Cost of decaning, dismantling coil any connection, testing and inner tank painting of stabilizer deemed to be inclusive
M&L for changing of burnt copper coil by new copper coil of voltage stabilizer 3x20 KVA complete with insulating material for core assembly purpose all as specified and directed Note : Cost of decaning, dismantling coil any connection, testing and inner tank painting of stabilizer deemed to be inclusive
S&F in repairs step synchronous motor of high torque single phase AC supply and shall have in start/stop, reverse characterstics & take very low current complete all as specified and directed
S&F in repair dimmer-stat/ variable voltage transformer type copper wound on high grade crgo/toroidel core of capacity 40 KVA complete all as specified and directed
S&F in repair dimmer-stat/ variable voltage transformer type copper wound on high grade crgo/toroidel core of capacity 20 KVA complete all as specified and directed
Supply and topup of transformer/ voltage stabilizer oil having dielectric strength 60KV as per IS complete all as specified and directed. Note : Oil shall be filled in the stabilizers to be repaired or installed at site at different locations.
M&L for digital card With high low cut off display Microprocessor based Auto manual function Both Buck and boost Single display for both input and output complete all as specified and directed
Supply installation commissioning of, 1HP sludge pump, ISI marked, including necessary accessories required for fixing accessories nylon rope of suitable size for carrying the pump in sludge well, including 15RM cable of suitable size and taking out existing unserviceable pump set from sludge well, and disposing off complete all as specified and as directed
Supply, installation commisioning of pump set submersible type of 2HP suitable for upto 100mm bore well, head upto 100mtrs, Discharge 30 LPM, Operating Voltage Range 160-240V single phase, 50Hz complete all as specified and as directed
S&F FASD three phase submersible pump starter comprises of power contactor, over load relay, single phase preventor, AV meter, three phase indicator lamp etc. complete with copper wiring housed in enclosure for capacity 50HP including proper fixing arrangement, copper cable thimble etc and including taking out old unserviceable starter and all as specified and directed Make: L&T model No MU-G50FASD/ siemens/ABB/ Schneider
S&F FASD three phase submersible pump starter comprises of power contactor, over load relay, single phase preventor, AV meter, three phase indicator lamp etc. complete with copper wiring housed in enclosure for capacity 30HP including proper fixing arrangement, copper cable thimble etc and including taking out old unserviceable starter and all as specified and directed Make: L&T model No MU-G30FASD/siemens/ABB/ Schneider
S&F single phase submersible pump controller comprises of suitable power contactor, over load relay, Start and Run capactor, Volt/Ammeter of suitable capacity etc. complete with copper wiring housed in enclosure suitable for submersible motor capacity 1HP including proper fixing arrangement, copper cable thimble etc complete all as specified and directed Make : L&T model No MR-G2 Or equivalent in Crompton/Schneider/ Seimens.
S&F in replacement of Discharge pressure gauges 100 mm nominal dia with control valve & syphon, socket, union and adopter, range 0-300 PSI fixed with 150 mm long, 15mm dia GI pipe medium grade with suitable arrangement for fixing on 80/100/150/200 mm DI/CI by using clamps, etc, including taking down existing unserviceable item complete all as specified and directed.
M&L for disconnecting alternator, 3 phase, 4 wire, 50Hz, 0.8PF, 415V, AC, 63kVA capacity, insulation, 50 cycles 1500RPM, self excited, self regulated, brushless type, at any position / location, collecting and transporting to workshop, taking out burnt winding, rewinding with new super enamelled copper wire as per original gauge, including providing insulating materials viz. cotton tape, packing, sleeves, etc. and varnishing by vacuum impregnation and baking of coil, duly re-fixing, bringing in at site, connecting all electrical connections, commissioning and testing 63/62.5KVA complete all as specified and as directed
Supply, lowering and packing pea gravel of size 2mm to 6mm size as per IS of natural shape brought directly from the riverbed pouring around casing pipe and slotted pipes in the borewell complete all as specified and directed. Note: - For the purpose of measurement gravel brought by the contractor shall be stacked properly at site & measurement of stacks shall be recorded before use and after use (left unused) to arrive at the net quantity of gravel used.
M&L for Development of tube well by 250 cfm and 600 PSI till clear water is obtained, including stabilization of existing bore well complete all as specified and directed
Supply, laying, jointing and testing of XLPE cable of cross sectional area 4Cx16Sqmm insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade complete all as specified and directed
Supply, laying, jointing and testing of XLPE cable of cross sectional area 4Cx25Sqmm insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade complete all as spd and directed by Engr in Charge.
Supply and laying PVC insulated cable submersible flat copper 3 core 16Sqmm 1100 volt grade, complete all as specified and directed
Supply and laying PVC insulated cable submersible flat copper 3 core 10Sqmm 1100 volt grade, complete all as specified and directed
Demolition of existing valve pit chamber, M&L for masonry valve pit of size 1500x1500x1050mm internal size complete with excavation, earth work and brick work in CM 1:6, 15mm thick plastering in CM 1:4 internally including 5mm thick MS Sheet cover and angle iron frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer complete with locking arrangement complete all as specified and directed.
S&F in repair supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed inclusive of one primer coat, one under coat and one finishing coat of paint, complete all as specified and directed
M & L for cement concrete (1:3:6) type C-2 (using 40mm graded mechanically crushed stone aggregate) as in padestal /foundation etc incl form work complete all as specified and directed including demolition of existing, complete all as specified and directed
Supply and installation in lieu of replacement chemical dosing system suitable to inject solution 25LPH working pressure 10kg/sqm comprising dosing pump coupled with three phase electrical motor of cap 0.5 HP 1440 rpm IP55, including its suitable 3 phase starter, FRP tank 100 ltrs,NRV, SS304 assy, Gland PTFE model made of powder coated MS fabricated pump and driving base complete all as specified and directed Make Minimax dosing Model MM-1/M/S sathya sai/ ion exchange.
M&L for earthing for machinery, LT feeder pillar box with galvanised cast iron earth plate of 600x600x6mm thick directly buried in ground not less than 2.25m below normal ground level, earth plate packed on all side with charcoal mixed with salt to a thickness of 150mm connected by GI earth strip of size 32x6mm thick soldered and riveted to earth plate. GI earth strip will be protected by using 50mm bore GI pipe (light grade) earth plate to equipment including flat iron clamp 25x3mm including bolts, nuts & washers complete including watering GI pipe 20mm dia light grade 2.5m long. The earthing includes PCC pit including necessary earth work and disposal of surplus soil to a distance not less than 50m , chamber of PCC (1:4:8) Type D-2 using 40mm graded mehcanically crushed stone aggregate, coping shall be of PCC (1:3:6) type C-1 using 20mm graded stone aggregate, RCC pit cover 50mm thick in (1:2:4) type B-1, using 20mm graded mechanically crushed stone aggregate, reinforced with 8mm MS bars at 80mm c/c both ways in lieu of CI pit cover and angle iron frame including funnel,wire mesh complete all as specified and directed Note : On testing, if the desired earth resistance is not obtained, entire earthing shall be re-done by contractor till the desired earth resistance is obtained without accruing any extra cost to the government.
Taking out of existing earth wire/earth plate etc and demolition of earth pit chamber complete all as specified and directed
Labour for lifting/lowering of column pipe flanged 100mm/80mm bore with submersible cable from bore hole of tube well, pump set of any capacity and lowering after repair in borewell complete all as specified and directed by Engr-in-Charge. Note: (i) Lifting & lowering of pump set upto 120mtrs deep will be deemed to be included in unit rate. (ii) Lifting & lowering of pump set to be completed out within 24hrs from intimation. (iii) Rubber gasket, nuts & bolts for replacement deemed to be included in unit rate.
M&L for rewinding of submersible motor with PVC coated copper winding wire as per existing gauge insulation material, after stripping of existing worn out winding, M&L for sealing kit, O-ring, Gasket, water drain plug, sand guard, cable packing ring, cable gland ring, upper/lower bearing, adopter piece, motor key, neck ring, suction case, Hex bolt, Circlip washer, Motor coupling, thrust plate, motor bush etc complete, reassembling with pump set of the 25-40HP capacity complete all as specified and directed
All as per BOQ srl item No 40.00 but for 1 HP-2 HP submersible pumpset (complete set of pump & motor) of any type, complete all as specified and directed
Supply and lowering of column pipe made out of GI pipe heavy grade 100 mm nominal bore each 3 meter length including flange duly welded with web complete all as specified and directed. Note: Cost of MS nut, bolt and washers and packing for column pipe deemed to be incl in unit rate.
Supply and lowering of column pipe made out of GI pipe heavy grade 80 mm nominal bore each 3 meter length including flange duly welded with web complete all as specified and directed. Note: Cost of MS nut, bolt and washers and packing for column pipe deemed to be incl in unit rate.
M&L for Repair/Overhauling of submersible pump including replacement of Hex bolt, Circlip washer, bowl stud, rotor bleach, pump bush, neck ring etc including repair complete all and reassembling pump set of 25-40HP capacities, complete all as specified and directed Note: This item will include all the connected acessories except the following mentioned items
Supply only in repair Thrust Bearing, complete all as specified and directed
Supply only in repair Bush for pump, complete all as specified and directed
Supply only in repair coupling bush, complete all as specified and directed
Supply only in repair Thrust bearing housing, complete all as specified and directed
Supply only in repair stage bowl, complete all as specified and directed
Supply only in repair Impeller GM, complete all as specified and directed
Supply only in repair Motor bearing bush, complete all as specified and directed
Supply only in repair SS sleeves, complete all as specified and directed
Supply only in repair sand guard
Supply only in repair Pump shaft
Supply only in repair Non return valve
Supply only in repair Diffuser
Supply only in repair Key for coupling pumpset
M&L for rewinding of electric motor of Cap 15 to 20 HP three phase 415 volts by removing burnt copper winding wire, cleaning of slots and insertion of insulating paper in the slots in appropriate size and rewinding with super enameled copper wire of suitable size superior quality of insulating material, winding, varnishing and drying, and refixing back after rewinding, replacement of connection plate and making necessary electric connection complete all as specified and directed.
All as per BOQ serial item No. 58.00 but capacity of 10 to 12.5HP, complete all as specified and directed
All as per BOQ serial item No. 58.00 but capacity of 5 to 7.5HP, complete all as specified and directed
All as per BOQ serial item No. 58.00 but capacity of 0.5 to 3HP, complete all as specified and directed
Repair/Overhauling of pump 7.5 to 20HP taking out impeller, shaft, stuffing box re-assembling the same after replacing the defective parts & carrying out the necessary repair remetalling, turning polishing the pump shaft including replacement of steel studs nuts/ bolts replacement of GM bush, ball bearing, stuffing box greasing etc and re-installation at site, checking of smooth functioning complete all as specified and directed. Note : -(i) The complete job includes making good the existing pumps water leak proof including gland/ packing and labour work for fixing following items etc. (ii) cost of spare parts except GM bush, Impeller, stuffing box and ball bearing shall be included in the quoted rate by the contractor repair of pumpset.
Supply only bearing for 7.5 to 20HP monoblock pump set complete all as specified and directed. Make:- SKF/NBC
Supply only GM Impeller for monoblock pump capcity 7.5 to 20 HP complete all as specified and directed.
Supply only Stuffing box alongwith pressure plate and hexa nuts, studs, gland packing as per existing make complete all as specified and directed.
Supply only Gun metal Bush suitable for monoblock pump set complete all as specified and directed.
M&L for Repair/Overhauling of pump set 3 to 5HP including replacement of GM bush, ball bearing if required, re-metaling, turning & polishing of pump shaft etc and testing commissioning and installation at site complete all as specified and directed. Note : -(i) The complete job includes making good the existing pumps water leak proof ,including gland/ packing etc. (ii) Spare parts i.e. GM bush, shaft sleeve and ball bearing will be measured and paid separately under relevent items. (iii) Dismantling of pumpset from site, disconnecting & refitting of water inlet & outlet, Decoupling/ dismantling of pump and motor and reinstallation at site deemed to be included in unit rate.
Supply only bearing for 3 to 5HP monoblock pump set complete all as specified and directed.
Supply only GM Impeller suitable for 3 to 5HP monoblock pump set complete all as specified and directed.
Supply only Stuffing box alongwith pressure plate and hexa nuts, studs, gland packing etc as per existing make complete all as specified and directed.
Supply only Gun metal Bush suitable for 3 to 5HP monoblock pump set complete all as specified and directed.
supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz indoor type, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheet duly powder coated and shall be CPRI approved .The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, cable gland, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on MS angle iron frame of suitable size duly painted including PCC 1:2:4 Type B1 (using 20 mm graded mechanically crushed stone aggregate) in foundation as the site requirement complete all as specified and directed by Engr-in-charged including comprising of following :- (a) MCCB 415 V 4 Pole 200 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 01Nos(incommer) (b) MCCB 415 V 4 Pole 160 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 01Nos (Outgoing) (c) MCCB 415 V 4 Pole 63 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 01Nos (Outgoing) (d) MCB 63 Amps, FP,10 KA, 415 volts, 50Hz-1 Nos (Outgoing) (e) Fully Automatic Star Delta Starter MU-G50 FASD, capacity 50HP (With Wideband Coil). Make& L&T Cat Pt No CS96009COJO- 01Nos (f) On-load change over switch 200 Amps, 4Pole, 415 V, 50Hz front handle operated type -01 No Make :- L&T/ABB/Havells (g) Digital Ammeter, with CTs & ASS-01 set (h) Digital voltmeter, with VSS-01 set (j) LED phase indication lamps RYB-01 set (k) CTs 3 Nos of current ratio 150/5A - Set of 3 (l) Aluminium bus bar TPN 300 Amps rating
supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz indoor type, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, cable gland, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on MS angle iron frame of suitable size duly painted including PCC 1:2:4 Type B1 (using 20 mm graded mechanically crushed stone aggregate) in foundation as the site requirement complete all as specified and directed by Engr-in-charged including comprising of following :- (a) MCCB 415 V 4 Pole 200 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 01Nos(incommer) (b) MCCB 415 V 4 Pole 100 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 03Nos (Outgoing) (c) MCCB 415 V 4 Pole 63 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 01Nos (Outgoing) (d) Fully Automatic Star Delta Starter MU-G30 FASD,Capacity 30HP (With Wideband Coil). Make& L&T Cat Pt No CS96009COJO- 03Nos (f) On-load change over switch 200 Amps, 4Pole, 415 V, 50Hz front handle operated type -01 No Make :- L&T/ABB/Havells (g) Digital Ammeter, with CTs & ASS-01 set (h) Digital voltmeter, with VSS-01 set (j) LED phase indication lamps RYB-01 set (k) CTs 3 Nos of current ratio 150/5A - Set of 3 (l) Aluminium bus bar TPN 300 Amps rating
Attending day to day complaints pertains to Electric driven motors/pumps and LT panels, Starter panels of any capacity as and when required with skilled Electrician and helper, with necessary T&P for checking the equipment at existing location and find out the faults/ defects and rectify the defects in situ, cleaning/ normal maintanance to the euipments (including fixing lugs, nuts, bolts, etc as required on site) complete to make the equipment functional in all respect complete all as spceified and directed by Engr-in-charge. Note : (i) Spare parts wiil be measured and paid separately.
Supply only following spare parts of Starter panels/ LT panels etc. all as specified and directed.
Indicating lamp
Voltmeter 0 – 500 V.
Ammeter 0–100A.
Single phase preventer system of supply 415 Volt 50 Hz.
Three phase monitoring relay, Digital type, or line voltage reversible- Phase- sequence, phase failure, under voltage/ over voltage feature, 3x160 volts to 440 volts AC, 50 Hzs complete all as specified & directed. Make: Seimens model No-3UG 4615-1CR20 or equivalent in schneider/ ABB
Start/ Stop switch.
Power contactors of capacity 15-70 Amp as per existing make
Star-delta Electronic timers.
Overload relay range of 9-100A.
Copper thimble 6Sqmm
Copper thimble 10/16Sqmm
Copper thimble 25Sqmm
Copper thimble 50/70Sqmm
Attending complaint of repair of chemical dozing pump, detection of fault and rectification of the defects at site and comprising of replacement of spare parts kit, pipe, foot valve, Injector nozzle, NRV, filter etc. complete all as specified and directed.
Chemical and Biological testing of water samples from approved laboratories to ensure potability of water as per IS complete all as specified and as directed Note: Container for sample shall be provided by the contractor and the cost to the same shall be included in the quoted rate.
S&F in replacement of Agitator for mixing of hypo-chlorite powder granules, stainless steel mixing rod alongwith single phase electric driven motor of capacity 0.5 HP and stand for fixing of Agitator system on chemical dozing tank complete with electrical connections connecting complete all as specified and directed.
S&F plunger type dosing pump 230 V AC 50HZ capacity upto 10LPH @10kg/cm2 pressure pump head PP with Glass filled , Teflon Diaphram. With suction and Discharge tubing 3mtrs along with PVC Injector with NRV complete all as specified and directed. Make:- Minimax, new india/ Sathya Sai/ ION Exchange
M&L for complete fixing in repairs for DG set accoustic enclosure door Hinges, locks with keys -02 sets including carring out necessary repairs/modifications complete all as specified and directed
M&L for scrapping old existing paint from pipe of dia upto 150 mm at installations including making smooth surface by filling putty and applying two coat of synthetic enamel paint of approved blue colour incl marking of inlet/outlet etc with the help of white colour or complete all as specified and directed.
Supply and distribution of only calcium hypochlorite granules containing 65% free chlorine in 45 kg container complete all as specified and directed.
S&F foot valve, 50/80/100mm dia size (CI strainer and GM working parts), single end flanged, one side flanged, including providing rubber gaskets of suitable size, nuts, bolts, washers, etc. and dsconnecting and taking down exact sizes unserviceable foot valve complete all as specified and as directed.
M&L for scrapping old existing paint from Pump Set of cap. 5 to 15 HP, motor and channel including making smooth surface by filling putty and applying two coat of synthetic enamel paint of approved colour complete all as specified and directed.
S & F of centrifugal pumpset of capacity 15 HP, 24-51Mtr head, three phase, 415 V alongwith its suitable star delta starter complete all as specified and directed by Engr in charge
Supply, installation, testing and commisioning of submersible pumpset of cap 24.5 KW/35HP, 14 stage, head range 286-53 Mtr, 0-90m3/hr, 3 phase, 200-440V including its reducer fabricated on site complete all as specified and directed by Engr in Charge.
M/S Sonu Traders (BID ID -3285276)
SWAMI ENGINEERS (BID ID -3286737)
Esha Engineers (BID ID -3286198)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .