| 1 | L1₹1.9 CrAccepted-AOC D 47 MANORATH SOCIETY NEAR AMAR COMPLEX SAMA ROAD VADODARA 390024 | VADODARA | GUJARAT | 390024 | ₹1.9 Cr Quoted ₹2.0 Cr | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹2.0 Cr+₹7.4 L (3.74%)Rejected-Finance G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA GUJARAT 390002 | VADODARA | VADODARA | GUJARAT | 390002 | ₹2.0 Cr+₹7.4 L (3.74%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹2.0 Cr+₹7.7 L (3.92%)Rejected-Finance HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | ₹2.0 Cr+₹7.7 L (3.92%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹2.2 Cr+₹23.3 L (11.8%)Rejected-Finance | ₹2.2 Cr+₹23.3 L (11.8%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹2.3 Cr+₹34.4 L (17.5%)Rejected-Finance | ₹2.3 Cr+₹34.4 L (17.5%) | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
27 Sept 2022, 6:00 pmClosed
CE JODHPUR ZONE
HQ CE JODHPUR ZONE
ADDN/ALTN AND SPECIAL REPAIRS TO ORs MD ACCN AND TYPE-I MES CIVILIAN ACCN AT LANCER LINES AT BARODA (JOB NO 01/AMWP/LIST-III/17/2022-23)
2022_MES_547114_1
800581/BRD/2022-23/E8
Open Tender
Civil Works
Item Rate
450 days
GE (A) BARODA
As per Tender Documents
9 documents required · 9 mandatory
₹2,000
GE (A) BARODA
₹2.9 L
Yes
HQ CE JODHPUR ZONE
27 Oct 2022
23 Aug 2022
29 Sept 2022
23 Aug 2022
27 Sept 2022
15 Sept 2022
2 Sept 2022
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed.
M&L for brick work with sub class 'B’ bricks using old size bricks, straight or curved on plan exc. 6 m mean radius, built in CM 1:6.
M&L for brick work with sub class 'B’ bricks, old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
M&L for rendering 10 mm thick in CM 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement.
M&L for rendering 5 mm thick in CM 1:4 mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement, over and including 10 mm thick rendering in CM 1:6 on brick work or concrete surfaces. Note:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”
M&L for rendering 10 mm thick in CM 1:4 on concrete surfaces in ceiling (facia/ceiling/edging of chajjas and roof projection) including finishing even and smooth without using extra cement.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted, over and including a coat of 2 mm thick Birla/JK wall care putty over a coat of primer all as directed.
M&L for preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white wash.
M&L for preparation of old decorated plastered or unplastered surfaces of ceilings by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil & greasy spots including cornices etc and applying one coat of white wash all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of Acrylic Emulsion Exterior (Apex Ultima) weather proof paint, white or tinted, over and including a coat of primer all as directed.
M&L for complete removal of existing treatment from walls and applying two coats of Acrylic Emulsion Exterior (Apex Ultima) weather proof paint, white or tinted, over and including a coat of primer all as directed.
M&L for complete removal of existing treatment from walls and applying two coats of distemper oil emulsion, white or tinted, over and including a coat of 2 mm thick Birla/JK wall care putty all as directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer.
Demolition of stone slabs and tiles of any description or thickness in floors and aprons etc. laid, bedded and pointed in any mortar and removing from site all as specified and directed.
M&L for roughening surface of old concrete by picking, sweeping clean and washing down with water to remove all loose dust etc.
M&L for preparation of new or previously untreated wooden surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
M&L for glazed ceramic tiles, coloured, 350x250x7mm/450x300x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:3 on stone masonry surfaces/brick work or concrete surfaces. (Tile pattern and decoration shall be as directed by Engineer-in-Charge).
M&L for 16 to 18 mm thick marble work of Udaipur green marble (table rubbed and polished) in single piece in cooking platform, pillars, window-cills, jambs, steps and like in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over and including 15 mm thick screed bed or bedding layer in CM 1:4.
M&L for 18 to 20 mm thick marble work of marble green/ Bhaislana zebra (table rubbed and polished) in single piece in cooking platform, pillars, window-cills, jambs, steps and like in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over and including 15 mm thick screed in CM 1:4.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations.
M&L for non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular) in floors etc. area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1:4.
M&L for non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:3 on stone masonry surfaces/brick work or concrete surfaces.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each and removing from site. Note - Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each and removing from site. Note - Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
S&F 35 mm thick factory made flush shutters, solid core construction, with block board core, both faces covered with decorative prelaminated work with 6 mm thick teak wood edging all round.
S&F 35 mm thick factory made second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a), supplied and fitted to chowkats.
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm single side prelam PVC sheet and edges will be painted to match with prelam sheet PVC sheet reinforced with M.S. square tube, fixing in opening as per specification and drawing.
S&F 30 mm thick factory made both sides prelam panel PVC door shutter consisting of frame made out of MS tube of 19 gauges thickness and size 19mm x 19 mm for stiles, top and bottom rails, MS frame shall have a coat of steel primer of approved make and manufacture. MS frame shall be covered with 5 mm thick heat moulded prelam PVC 'C' channel size 30 mm thickness, 70 mm width, out of which 50mm should be flat and 20 mm shall be tappered in 45 degree < on either sides forming stiles and 5 mm, 95 mm wide prelam PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide. prelam PVC sheet out of which 75 mm shall be flat and 20mm shall be tappered on both sides to form lock rail. Top rail, bottom rail and lock rail shall be provided either sides of the panel 10 mm (5 mm x2) thick 20 mm wide cross PVC sheet shall be provided as gap insert for top rail, and bottom rail paneling of 5 mm thick both side prelam PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with 7 mm (5 mm+2 mm) thick 15 mm wide. PVC sheet beading on inner side and jointed together with solvant cement adhesive, an additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of C channel using PVC solvent adhesive etc. complete all as specified and directed.
Supply and fixing factory made 18 mm (+0.7mm) thick PVC sheet one side prelam sheet for cupboard shutter and frame of size 50x50 mm of matching colour, of density 600kg/Cbm bent 90° and finish at all edges at level for making edges at level for making edge lipping/bending or 0.5mm thick PVC sheet lipping at 4 edges using bonding tape including SS hinges etc. complete as per direction of Engineer-in-Charge and manufacturer's specification.
S&F stainless steel grade 202, 14 gauge thickness, butt hinges, medium weight, of size 100 mm.
S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
S&F 150 mm size aluminium handles, cast type, anodised.
S&F 150 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed.
S&F floor door stopper, with 150 mm long cover plate, of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor.
S&F hasp and staple of size 100 mm, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws.
S&F mild steel of grade Fe-290 (Grade E-165) in framed work such as grills, grating etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders; ramed balusters; walk ways; railings; framework of water tanks and similar works.
S&F pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified.
S&F pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified.
S&F anodized aluminium powder coated of any colour (minimum thickness of powder coating 50 micron) frame and shutters for doors, windows, ventilators, partition wall etc. with one or more rebates, including joining cleat for fixing etc. complete all as specified. Note:- Sheet glass and builders hardware shall be measured and paid for separately.
S&F anodized aluminium powder coated of any colour (thickness of powder coating not less than 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150 mm long (01 No.), hinges type B-21 100 mm long (02 Nos.) suitable handle (01 No.) complete all as specified.
S&F sheet glass 4 mm thick, ordinary quality and glazing with neoprene beading in square n. exc. 0.5 sqm in each pane.
S&F sheet glass 4 mm thick, figured glass, pin headed type and glazing with neoprene beading in square n. exc. 0.5 sqm in each pane.
S&F stainless steel wire cloth, 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden beads supplied with shutters.
M&L for PCC 1:3:6 type C-0 using 12.5 mm graded stone aggregate in cills, steps, bands, copings, bed plates, blocks for inserting hold fasts, filling back of chowkats etc. and the like including weathering, slightly rounded or chamfered angles and throating as directed.
S&F in repairs 22 to 25 mm dia stainless steel curtain rod, fancy type/decorative type, fixed to walls complete all as directed.
S&F in repairs, stainless steel decorative finials (round type with mirror optic finish trade/standard pattern suitable for 22 to 25 mm dia decorative/fancy type curtain rods.
S&F in repairs sink made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm and PVC waste pipe of 32mm bore and of suitable length, complete all as specified.
S&F in repairs stainless steel plate rack, 0.65 mm thick of standard pattern, of size 610x610x254 mm suitable for stacking plates with hooks/fittings complete all as specified and directed.
M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc. and making good, cutting not exc. 10 cm girth.
Dismantling water tanks of any description, exc. 250 & n. exc. 500 litres capacity and removing from site.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top), white in colour outside and inside, hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes.
Taking up or down steel tubing 15 mm bore and connections including cleaning for refixing or removing from site.
Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removing from site.
Taking up or down steel tubing 25 mm bore and connections including cleaning for refixing or removing from site.
Supplying and laying of 16 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings in trenches, fixing on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings in trenches, fixing on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of 25 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings in trenches, fixing on walls/ceiling or laying in floors complete all as specified.
S&F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges.
S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including embedded and set in PCC 1:5:10 type E-2 and making good to floor including removing rubbish with and including PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe, 32 mm dia complete all as specified.
S&F in repairs vitreous china wash basin, white/ivory, oval type, size 450x300 mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32 mm bore and of suitable length complete all as specified.
S&F in repairs 15 mm bore pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed.
M&L in repairs for PVC (SWR) floor trap, suitable for type ‘B’ pipes, 75 mm dia of outlet, plain with grating including jointing with solvent cement.
M&L in repairs for PVC (SWR) gully trap, suitable for type ‘B’ pipes, 125/110 mm setting and jointing with solvent cement.
S&F in repairs 15 mm bore stop valve/angle valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.
S&F in repairs 15 mm bore brass CP mixer for mixing hot and cold water screwed down for iron pipe as per cat part No. 8775 of Make - Prayag or techno commercially equivalent of any make specified.
S&F in repairs15 mm bore bib taps, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F in repairs brass chromium plated shower rose of 125 mm size with swivel joint including fixing to steel pipe or union.
S&F in repairs 20 mm bore ball brass valves, high pressure, with polythene float and fly- nut complete, screwed for iron pipe or brass ferrule and fixed.
S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe.
S&F 110 mm bore UPVC (SWR) WC connector with lip ring.
S&F 110 mm bore UPVC (SWR) WC connector bent type.
S&F in repairs 110 mm bore UPVC (SWR) junction, suitable for type ‘B’ pipes, single (single T) equal or unequal.
S&F in repairs 75 mm bore UPVC (SWR) junction, suitable for type ‘B’ pipes, single (single T) equal or unequal.
Dismantling of cast iron or reinforced concrete drain pipes of 100 mm internal dia, jointed in cement mortar and taking out of trenches, if required.
Dismantling of cast iron or reinforced concrete drain pipes of 75 mm internal dia, jointed in cement mortar and taking out of trenches, if required.
S&F 110 mm bore UPVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints fixed to walls.
S&F 110 mm bore UPVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints, laid in trenches or in floors.
S&F 75 mm bore UPVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints fixed to walls.
S&F 75 mm bore UPVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints, laid in trenches or in floors.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 600 mm.
M&L for repairing by brushing of treatment to reinforcement by application of corrrosion resisting coat in two coats, suitable time to be provided between coats according to manufacturers instructions to resist further deteroriation of reinforcement etc complete
M&L for repairing by application of approved epoxy based bond coat on concrete surfaces or sound bonding of old and new concrete surfaces complete.
M&L for making of profile of structral memebers with polymer modified mortar in damaged areas 1:3 (Cement:sand) mortar with 5 -10 percentage addition of latex polymer, w/c ratio of 0.35 in 20 mm thk layers / including leveling etc complete.
M&L for complete removal of loose/ cracked concrete including reinforcement if required from RCC roof projection, chajja, fins, facia etc and making good with PCC (1:1½:3) type A0 using 12.5 mm graded aggregate in any slab and in any position finished the surface fair and even and smooth complete making good to match with existing surfaces complete. Note :- Reinforcement and form work shall be measured and paid for seperately under respective items.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M&L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M&L for form work to flat, rough finished surfaces of concrete of chullah hoods, chajjas, troughs and similar items including edges.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for (roof padding/roof kerb/sunken floor etc.) including tarfelt, plaster etc. and removing from site all as specified and directed.
M&L for cement concrete 1:2:4 type B-0 mix (12.5 mm graded stone aggregate) in padding over roof of any thickness.
M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof) mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement complete all as specified. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”.
M&L for applying roof treatment on top of roof with APP modified membrane (minimum 3 mm thick) weight not less than 3.00 Kg/sqm and reinforced with non-woven polyster reinforcement/mat (centre core) with thermal insulation with polythene finish on upper side of membrane, laid by torch application method with overlaps 150 mm on length side and 100 mm on the width side as per manufacturer’s instructions over and including a coat of bitumen S-35 (30/40) @ 1.20 kg/sqm over and including a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 0.40 litre/sqm and providing a seperation layer over the APP surfaces of Geotextile 120 gm non woven 100% polyster of thickness 1 to 1.25 mm. Geotextile to be bonded to the APP membrance by intermittent touch by heating process with Butane torch all as per manufacturers instructions complete all as specified and as directed by Engineer-in-Charge.
M&L for premium first quality cool roof SRI (Solar Reflective Index) tiles of size 300x300mm 10mm thick of approved make as approved by GE. The SRI value of the tiles shall be greater than 90 as per ASTM-E 1980 and water absorption less than 5%. The glaze of the tiles shall be composed of alumia silicate fine particles embedded with nano particles of zirconium silicate and zink oxide admixtures fired back at very high tempreatures. The tiles shall be laid with a space of 3mm between to all sides using PVC spacers. The tiles shall be laid over 15mm thick bedding in CM (1:4) joints grouted and pointed in CM (1:3). The top 5mm thickness of the tiles in between the joints shall be filled with epoxy grout of approved make.
Supply only liquid water proofing compound.
M&L for cement concrete (1:5:10) type E-2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete/sunken floors all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”.
M&L for 15 mm thick rendering on floor and vertical side of sunken floor of stone masonry surfaces/brick work/concrete surfaces in CM (1:3) mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement and finished even and smooth without using extra cement complete all as specified and directed. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”.
M&L for applying roof treatment on sunken floor with APP modified membrane (minimum 3 mm thick) weight not less than 3.00 Kg/sqm and reinforced with non-woven polyster reinforcement/mat (centre core) with thermal insulation with polythene finish on upper side of membrane, laid by torch application method with overlaps 150 mm on length side and 100 mm on the width side as per manufacturer’s instructions over and including a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 250 gm/sqm complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate in plinth protection. Concrete shall be laid in alternate bays n.exc 3 m in length finished fair and even including provision of joints of 6 mm wide and 10 mm deep along the wall and bays filled with bitumen mastic (1:3).
Demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and removing from site all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B1 using 20 mm stone aggregate in lintels up to 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including form work ,weathering, slightly rounded or chamfered angles and throating, as directed. Note :- Reinforcement shall be measured and paid for separately.
M&L for machine cut kota stone slab 20-25 mm thick in shelves, support of cooking platform, below marble or granite cooking platform, set and jointed in CM 1:4 complete.
S&F in repairs, vitreous china wash down water closet pan (pedestal pattern), white, with and including PVC (SWR) 'P'/'S' trap type 'B', plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, and health faucet (ABS body) mild steel chromium plated suitable for 15 mm bore pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position and PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe, 32 mm dia complete all as specified.
M&L for form work to soffits of flat, rough finished surfaces of concrete of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick(Horizontal or sloping)
M&L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10 cm but n. exc. 20 cm wide, rough finished surfaces of concrete.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves and the like.
Surface excavation n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil.
Add to (or deduct from) item No.111 above for every 3 cm or part thereof above or below 15 cm average depth. Note:- This item is for adjustment of rate only.
Removing excavated material (soil) exc. 1.5 Km but n. exc. 5 Km and depositing where directed at a level n.exc. 1.5 m above the starting point.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in sub base.
S&F 60 mm thick, M-35 grade, coloured, machine pressed PCC interlocking paver block, with grey cement and pigment, any shape and size laid dry over and including 25 mm thick screened river washed sand cushion.
M&L for chequered cement concrete tiles 20cmx20cmx25 mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry in floors over and including 15 mm thick screed bed or bedding layer in CM 1:4.
M&L for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment of soil under existing floors using emulsion at the rate of 1.00 litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors.
M&L for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall below concrete or masonry apron using chemical emulsion at the rate of 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete.
S&F welded steel wire fabric n. exc. 4 kg per sqm, fixed complete to wood or steel members.
Excavating in trenches in soft/loose soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point.
M&L for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc all as specified. (Reinforcement shall be measured and paid for separately).
Demolition and breaking up drain pipes, 150 mm internal dia (Salt glazed stoneware, AC or reinforced concrete) set in cement mortar and removing from site all as specified.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 150 mm bore, including packing under and haunching against the sides of pipes after they are laid and tested.
M&l for cutting into existing manholes for connecting new drains of 150 mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( ½ round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required.
M&L for cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete/sunken floors all as specified and directed.
M&L for RCC M-30 (design mix) using 20 mm graded stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs and mass concrete.
M&L for RCC M-30 (design mix) using 20 mm graded stone aggregate in walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses
M&L for form work to sides of flat, rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter.
M&L for form work to flat, rough finished surfaces faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses etc.; vertical or to batter.
M&L for 10 mm thick rendering in CM 1:3 on brick work or concrete surfaces mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement, finished even and smooth without using extra cement, complete all as specified. NOTE : Liquid water proofing compound shall be measured and paid for separately as “Supply only”
M&L 150 mm dia DWCPE pipe of class SN8 complete laid in trenches, fixed and jointed with integral socket or coupler and EPDM sealing ring and tested all as per IS-16098:2013 complete all as specified and directed.
Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces.
Taking down DB with MCB any type/any size & single pole and neutral enclosure with two pin and earth plug with MCB including all connecting accessories.
Taking down sub main wiring/service connection any type/any size including pipe and all connecting accessories.
M&L for point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit 20 mm dia with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick bakelite sheet white/coloured top cover for:- (a) One light/fan point controlled by one, one way switch.
All as per item No. 137 above but for one light point controlled by two, 2 way switches.
All as per item No. 137 above but one bell buzzer point controlled by one, bell push switch 5 A
All as per item No. 137 above but one 5 pin 5 or 6 Amps switch socket combination on same board with other switches as directed.
All as per item No. 137 above but one 5 pin 5 or 6 Amps switch socket combination on independent board as directed.
M&L for point wiring complete with 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit 20 mm dia with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed in wall, ceiling etc including sunken type pressed steel terminal boxes of size 175/100mm with 3mm thick bakelite sheet cover white/coloured including 2.5 Sqmm, single core, PVC insulated but unsheathed copper conductor FRLS 1100 volts grade cable as earth continuity wire for one 6 pin 15 or 16 Amps switch socket combination on independent board.
S&F switch piano flush button single pole one way 5/6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush button single pole two way 5/6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F bell push, flush button single pole 5/6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F switch socket combination 5 pin 5/6 amps flush type, 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F switch socket combination, 6 pin 5/6 and 15/16 amps multi purpose 2 in 1 flush type, 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F fan regulator electronic, switch type hum free with polycarbonate body suitable to control speed of fan from 0 to 100% and connecting electrically all as specified and directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F bell electric heavy duty Ding Dong type 230 volts single pole all as specified and directed by Engineer-in-Charge.
S&F 7W LED Bulb with B22 lamp holder. System Efficiency should be > 85 lm/ W. PF > 0.9, The Lamp Should have Cool Daylight Color temp of 6500K, lumen output >600 lm.
S&F 4' 18W LED Tube With Batten with system lumen output of 1800 lumens. System Efficacy should be > 100lm/W. The Luminaire Should have Cool Daylight Color temp of 6500K & CRI>80. Life 40K burning hrs with 70% lumen maintenace. PF>0.95 Surge Protecton of 3KV. All the Photometrical & Electrical parametrs must be supported by LM79-08 test report from NABL Accridiated LAB OR UL, R9 Value > 0. Lamp starting time is not more than 1 Sec. The LED tube light conforms to applicable IS. Housing of Batten should be made from single piece powder coated CRCA sheet as per Make- Crompton cat part No. LDSL 18-CDL with Master TLED 18W 1800 Lumens or techno commercially equivalent of any make specified.
M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
S&F and testing factory made sheet metal enclosure for MCB DB SPN 8 way with 200 amps rated bus bar, 240 volt with double door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
S&F MCB double pole 240 volts of rating 32 amps, with rupturing capacity 10 KA, 'C' curve type, with over load and short circuit protection.
S&F MCB single pole 230 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, 'C' curve type, with over load and short circuit protection.
S&F for energy saving and enviornment friendly long life LED security light fitting 1 x 35W LED, versatile pressure die cast aluminium IP-66 protection with high power LED as light source and arcylic cover etc all acessories prewired complete including mounting bracket of 40 mm inner dia light grade of required length and shape incl bending, forging or welding etc necessary connection to ceiling rose etc & suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 Sqm three core from ceiling rose to fitting all as specified and directed.
S&F exhaust fan, heavy duty metal body, 3 blades, double ball bearing, BEE rating not less than 3 Star, AC single phase 250 mm sweep complete with louvers including fixing/grouting of frame & connecting with & including 3 core PVC insulated copper conductor flexible cable of size 23/0.0076 (or eq. Size in mm) from ceiling rose to fan complete all as directed. Note:- Quoted rate shall be deemed to be included for cutting hole/making opening in wall for fixing of exhaust fan and making good the disturbed surfaces.
S&F in repairs ceiling fan AC single phase 230/240 V of size 1200 mm sweep, white colour, BEE 5 star rated including connecting with PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50 sqmm all as specified and directed by Engineer-in-Charge. Note :- Old ceiling fans shall be deposited to MES Store Yard.
S&F electric storage water heater ABS body with SS inner tank of capacity 25 litres BEE 5 star rated including proper installing arrangment on wall surface with suitable Anchor bolt fatser and Geyser connections for hot and cold water supply made of stainless steel wire braided connrtector with chrome finish heavy duty nuts of 15mm size with suitable lengh etc complete all as directed by Engineer-in-Charge.
M&L for in repairs earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Note:- Cutting chases in walls/floors/ceilings wherever required for electric work shall be deemed to be included in respective item of Schedule ‘A’.
City Light
Harsh Infrastructure
SLB Enterprises
SHISHODIA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .