Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.4 L+₹5,694.98 (0.69%)Rejected-AOC ERNAKULAM | KERALA | 680667 | L2 | Rejected-AOC L2 |
Tender Value
₹8.3 L
EMD Value
₹20,800
Closing Date
1 Feb 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE North
EE North, Thiruvananthapuram corporation
Providing electrification in the newly constructed building for Vanitha Souhrtha centre in Karikkakam Ward behind Zonal office Kadakampally under City Corporation Thiruvananthapuram.
2023_LSGD_552713_1
EE(N)/PLANFUND TENDER/2022-23(15)
Open Tender
Electrical Works
Item Rate
90 days
Karikkakam Ward
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,700
Yes
₹20,800
Yes
1 Mar 2023
25 Jan 2023
3 Feb 2023
25 Jan 2023
1 Feb 2023
25 Jan 2023
Amount
90.2.1.1 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade, and continous earthing with 14 SWG copper earth, required quantity of copper earth socket, brass bolt and nuts crimping/soldering etc complete with suitable size metal switch boxes modular type metal switch boxes modular type frond plate (white ) etc.upto and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switches and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories)
90.2.1.1 Single control light point with 6A, 3 plate ceiling rose
90.2.1.2 Twin control light point with 6A, plate ceiling rose
90.2.1.3 Single control light point with out ceiling rose
90.2.1.4 Single controll ceiling fan point with 6A.3 plate ceiling rose and with socket typepped electronic regulator
90.2.1.6 Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
90.2.1.7 Independent plug
9.3.20.3 Supply & installation of light fittings on TW round block supply conveyence installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamp etc, directly on wall or ceiling with PVC round block neatly painted to suit the fittings and giving connection with required length of 16/0.20mm 3 core coper conductor flex wire conforming to relevant ISS and giving connections as required. 1200mm 1x20W LED lamp with box type fixture
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required
od1491527/2021-22 Supply and providing the following types and power rated lamps in the existing fittings as required 10W LED bulb
od1491528/2021-22 Supply 305 mm sweep Heavy duty exhaust fan in metal frame working on 230V A/C
90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
od 1753271 / 2022-2023 90.4.5.4 Supply,installation testing and commissioning of ceiling fan of the following sizes including wiring the down rods standard length (up to 30 cm )with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc.as required. 1200mm sweep ceiling fan complete with service value minimum 4.0 (cub meter/ minite /watt ) air delivery minimum 210 cubic meter / minite )copper wiring suitable for 230/240V single phase A/C supply
90.11.1.20 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.11 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required
2.1.3 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.17 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1.17.1 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.14 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
1.17.31 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
90.12.7.28 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
90.3.18.2 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
90.15.4.3 Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105 lumen/ W 4000-6000 K with IP 66 protection LED chip make Cree/ Lumilled / Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and aluminium pressure die cast Powder coated housing acrylic cover complete with THD less than 10% power factor gre ater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be separatly accessible for maintanance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer
1,17.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 X 2.5 sq.mm
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earthelectrode, including connection/ termination with GI thimble etc. as required.
5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
5.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
OD54399/2022-2023: Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of folowing size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. size not less than 700x450x210mm
S & F switch disconnector fuse unit complete with handle assembly, door inter lock and padlocking arrangement of the following ratings. 63A
or Supply and fixing the following accessories in the existing meter board and giving connections etc as required
MR 1460 63 A HRC fuse base with HRC fuse link
MR 1468 63 A 2 way neutral links mounted on DMC/ SMC base
Amount remitted to KSEB for obtaining Power supply (actual amount will be reimpersed on production of original receipts)
B SASIKUMAR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_811173.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .