Loading…
Loading…
Tender Value
₹1.1 L
EMD Value
₹2,000
Closing Date
30 Sept 2026, 5:00 pm3d left
Dy. Executive Engineer, Sachivalaya Complex Electrical Sub Division No 2, Gandhinagar.
Renovation of Panchayat, Gram Gruh Nirman and Gram vikash vibhag office at 5th floor of block-8 at new sachivalay Gandhinagar.
345710
11/8
Open
Electrical
Works
Gandhinagar
7 documents required · 7 mandatory
₹600
Executive Engineer, SACHIVALAYA COMPLEX ELECTRICAL DIVISION,GANDHINAGAR
₹2,000
17 Sept 2026
17 Sept 2026
17 Sept 2026
30 Sept 2026
17 Sept 2026
BILL OF QUANTITIES(%TENDER)
:: BILL OF QUANTITIES::
Name Renovation of punchayat, gram gruh nirman and gram vikas vibhag office at 5th Floor of Block No -8 at New
of Sachivalay Dist. Gandhinagar.
Item No Description of item(with brief specification and reference to book of specifications) Qty Unit Amount
Replaced Old & Unservicable By New Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire
of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on PVC / Metallic/Wooden box, single
mounting base frame covered with textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.(f)
with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat.
Replaced Old & Unservicable By New Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5
sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected with 6A Modular type switch and hum free
EME step type electronic fan regulator mounted and accessories with earth continuity of following
type erected on PVC / Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with
necessary ceiling rose / H.D.Connector as directed.(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling complete Cat. III
Replaced Old & Unservicable By New Point wiring for on board Looped Plug with 6A Modular type
switch & 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate modules erected on / in wall / ceiling with following type
accessories Cat. III
Replaced Old & Unservicable By New Providing following type of Modular Type Accessories
mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site situation
directed by Engineer In charge.(1)One No. SP 6 Amp. Cat.III
(2) One No 5 pin plug Cat.III 9 Ea. 151.50
(3) Two Pin/RJ-11 Telephone Socket [A] For One Gang Cat.III 2 Ea. 160.59
(7) Blank Plate Single Cat.III 6 Ea. 25.25
(9) 16 Amp. SP one way switch Cat.III 4 Ea. 180.79
(10) 6/16Amp. Universal socket Cat.III 4 Ea. 199.98
Replaced Old & Unservicable By New Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in
approved manner as directed (b) 25 mm
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes,
Check-nuts etc. complete of following sizes. (2) 25 mm
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid
material with ignition free and flame proof confirming BS with necessary end caps Internal and
external bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following
sizes (2) 100 mm x 50 mm trunking
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6
mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed
water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge
and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having
following size of dimensions and No of compartments (W x D x T) Cat-III [3] 100mm x 25mm x
mm with one compartment
Replaced Old & Unservicable By Providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected
9 concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated Mtr. 58.58
stranded wire of green colour for earth continuity of following size (E) in existing pipe (a) 2 wire
(b) 2 wire 2.5 sq. mm 35 Mtr. 78.78
Replaced Old & Unservicable By New providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on
wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour
for earth continuity of following size (E) in existing pipe (a) 2 wire 4 sq. mm
Replaced Old & Unservicable By New Supplying & erecting approved make Telephone Cable
electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape &
11 sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C- Mtr. 20.20
DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary
connections.[A] Conductor Size 0.5 mm (a) Unarmoured (2) Two Pairs
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction [C]
Replaced Old & Unservicable By New Providing & erecting Switch board for Computer or electric
apparatus consisting of following modular type accessories mounted with PVC / Metallic
concealed/open box with single mounting base frame covered with textured/metallic /white front
13 plate,modules erected with necessary connections as directed Ea. 1133.22
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type Accessories Cat. III
14 Decorative call bell Ting-tong box type 250 volts complete erected 3 Ea. 71.71
BILL OF QUANTITIES(%TENDER)
Item No Description of item(with brief specification and reference to book of specifications) Qty Unit Amount
Replaced Old & Unservicable By New Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
15 CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between
the ranges shown.) (A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision
for spring loaded mounting clips complete.IP20 (ii) 11-15 watts, Surge-2 KV Cat-lll
B) LED Panel Light with provision for Plane front frame with translucent cover fixed to housing
complete.IP20 (vi) 36 watts, 24" x 24", Surge- 2KV Cat-lll
Supply, Installation, Testing and Commissioning of suitable sweep, BEE 5 Star rated, Ceiling fan
with Brush Less Direct Current (BLDC) permanent ferrite magnet Motor, class of insulation: B, Rust
free 3 nos.Aluminium blades, 2 nos. canopies, shackle kit with earthing provision, copper winding,
Power factor not < 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM,
16 350 RPM,230v (tolerance as per IS : 374-2019), THD < 10%, with remote unit for Speed Control Ea. 2885.57
and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree
C (Max.), suitable for 140 to 285 Voltage and rectifier circuit with surge, over current and overload
protection , 50 Hz, Single phase AC Supply, earthing etc. Complete as required.[ Make shall be
approved by Engineer in Charge] (B) 1200 mm Sweep (48")
Replaced Old & Unservicable By New Supplying and erecting 19 / 20 mm. nominal bore Medium
17 Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation without Ea. 108.07
leakage and earthing.
Providing Fan clamp of 30 x 5 mm flat of required length & 10 mm M.S. Bolt & Nuts erected with
necessary hook of 10 mm M.S. Round Bar.
Shifting of Split A.C. The Scope includes dismantling, shifting, re-installing & re-commissioning of
19 the units including topping up of Refrigerant gas, minor civil work wiring existing piping M S Stand Ea. 1969.50
electrical cabling with PVC drown piping for 1.00, 1.5 & 2.0 TR capacity.
Supplying and erecting insulated pair of soft copper tubing open or concealed including power and
control cable,necessary PVC drain pipes for Split/Cassette AC machine up to 4 TR capacity
21 Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.(E) 19 mm dia. 4 Rmt. 80.80
carry out RCC Core cutting- up to 100 mm dia./300mm thick Wall/beam/slab with providing PVC
pipe of 3 mm thick inside and necessary finishing on both ends of wall .
One lakh seven thousand seven hundred seventy-four point zero seven
I/ We am/are willing to carry out the work at_________% above / below percent (should be written in figure & words) of the estimated mentioned above. Amount of
my / our tender works out as under.
Estimated amount put to Estimated amount put to
(a) I/we hereby declare that we have visited the site and fully exquisite myself/ourselves with the Local situation regarding materials labour and other factors
pertaining to work before submitting Tender.
(b) I/we hereby declare that we have carefully studies the conditions of contracts. Detailed Specification and other tender document of this work and agree to
execute the same accordingly.
1 If required and found necessary material to be used for this work and brought at site will have to sent to Govt.approved laboratory. The qualified agency/
manufacturer of Particular product under testing will have to pay/ bear necessary charges.
2 All works shall be carried out as per public works Department hand book and other Specification.
3 Rates are inclusive of 1% Labour cess in tender amount so 1% of total amount of bill will be deducted from the bill.
3 Rates are inclusive of 1% Labour cess in tender amount so 1% of total amount of bill will be deducted from the bill.
4 The material to be used in this work must be as per instruction by under liason of Engg. In charge.The agency will have to agree to carried out the work as
per brand/make demand of concern deptt.
5 Contractor must have registration in E-2 & above class registered under elect. (R & B) division.
Sign of Dy. Exe. Engineer Exe. Engineer
ctor Sachivalay Complex Elect. Sub-Div.No.-2 Sachivalay Complex Elect. Div
R. & B. Deptt. Gandhinagar R. & B. Deptt. Gandhinagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
G S T LTR.pdf
GR.pdf
nivida 10.pdf
Block 8 5 floor boq .pdf
Block 8 5 floor dm.pdf
Block 8 5 floor SBD Book.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .