Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.5 L+₹19,901.50 (0.51%)Rejected-Finance | L2 | Rejected-Finance Second Lowest | |
| 3 | L3₹40.2 L+₹87,050 (2.21%)Rejected-Finance | L3 | Rejected-Finance Third Lowest | |
| 4 | L4₹42.4 L+₹3.1 L (7.96%)Rejected-Finance | L4 | Rejected-Finance Fourth Lowest | |
| 5 | L5₹42.9 L+₹3.6 L (9.27%)Rejected-Finance | L5 | Rejected-Finance Fifth Lowest |
Tender Value
Refer Docs
EMD Value
₹91,060
Closing Date
1 Sept 2021, 9:00 amClosed
Major Sameer Wadekar
GE Palampur, Holta Cantt, Palampur
SPECIAL REPAIRS TO DRAINAGE NEAR GR, EME AND OTHER LOC AND CERTAIN OTHER SANCTIONED WORKS AT PALAMPUR MIL STN
2021_MES_467222_1
GEP/ - /2021-22
Open Tender
Civil Works
Item Rate
180 days
Palampur Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹91,060
Yes
30 Sept 2021
11 Aug 2021
3 Sept 2021
11 Aug 2021
1 Sept 2021
18 Aug 2021
Amount
SCHEDULE 'A' PART-I Excavation over areas n. exc 1.5m in depth and getting out in hard/dence soil, complete all as specified and directed.(Manual excavation)
Plain cement concrete type D-2 (1:4:8) 40 mm graded crushed stone aggregate in foundation filling and mass concrete, complete all as specified and directed.
Walling of random rubble stone masonry brought upto course, with best quality locally available harder stones such as granite, trap, basalt stone etc, well bonded, bedded and solidly hearted , built in cement mortar 1:6, complete all as specified and directed.
PCC M-15 nominal mix as in precast bond stones set in cement mortar 1:6 complete with joints to match complete all as specified and as directed.
Extra over stone walling(Granite or trap stone) for hammer dressing with maximum depression on face from a straight edge held against the dressed surface n exc exceeding 20mm and dressing to face beds and joints as specified.
Broken stone or boulders hand packing (any thickness) at back of walls over arches etc & raising /lowering to the required level ,complete all as specified and as directed.
Supply only 110mm dia PVC (SWR) pipes, single socketed in any length as in weep holes, complete all as specified and as directed.
M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded creshed stone aggregate cast in situ in lintels up to 1.5 m clear span, cills steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones(fixing hold fasts), bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straigth or curved) complete all as specified & directed.
M&L raised pointing to random rubble stone masonry,un-courses or brought upto course in cement mortar 1:4 complete all as specified and directed.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
Removal of excavated material (soil) to a distance exc. 1.5KM and n. exc 5.00 KM, depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for,removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for,removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
Taking down chowkats or frames incl shutters (without taking off shutters from the frames) n.exc. 1.50 sqm each, and removing from site, complete, all as specified and directed.
Taking down chowkats or frames incl shutters (w/o taking off shutters from the frames) exc. 1.50 sqm but n.exc. 4 sqm each and removing from site, complete, all as specified and directed.
Dismantling of old rested plain or corrugated steel sheeting, any gauge, thickness,including Nainital or similar pattern roof covering etc. complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F anodised aluminium snap grid frame work 605mm x 605mm for false ceiling including hangers 6mm dia GI(upto1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of G.I. flat iron of size 40mm X 3 mm, 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L 4mm thick E-board (classic) false ceiling of size 600x600 mm fixed to aluminium snap grid false ceiling complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, compete all as specified and directed. (Colour as approved by GE)
M&L pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, facia and fixed with self tapping screws as specified. (Colour as approved by GE)
S&F Pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer, complete all as specified and directed.
S&F pressed steel frames of size 165mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer,complete all as specified and directed.
PCC type B-0 (1:2:4) using 12.5mm graded crushed stone aggregates as in filling of steel chowkats or frames complete all as specified and as directed.
S&F, solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, supplying and fixing in opening as per specifications & directed.
S&F 35mm thick factory made 2nd class hard wood rail and style plain framed, panelled shutter with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 (part 1) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35mm thick, 2nd class hard wood, factory made, glazed & skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. Sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24 (a) complete all as specified and directed.
S&F factory made EPS core solid PVC door shutter with wood free EPS board 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on front face and 2mm plain colour PVC sheet on back face. The door on all the edges to be sealed with lipping of 10mm (5mm x 2) thick x 25mm wide PVC sheet for 3 sides and 60mm wide PVC sheet for lock side. The lipping shall be bonded to the 2mm moulded/plain PVC sheet with solvent cement complete all as specified and directed.
Plain cement concrete M-10, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified & directed. Note:- The unit rate include for use of form work (straight or curved).
Dismantling floor, hearth or wall tiling including cement mortar bedding and backing coat, and leaving surface clear for backing coat etc, removing unserviceable materials,debris and rubbish to distance not exceeding 100m complete all as specified and directed.
M&L mat finish joint free non-skid, premium class I grade, coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.06 sqm but not exc 0.11 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L coloured glazed ceramic tiles in vertical surfaces 350mm x 450mm x 7mm / 450mm x 300mm x 7mm / 600mm x 300mm x 7mm as in skirting/dado etc, over and including 10mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L mat finish joint free non-skid, premium class I grade, coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18sqm but not exc 0.38 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
S&F box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick MS tube factory made with double side shutters wire gauged shutters & glass glazed shutter(wire mesh and glass panes shall be measured and paid separately) with side hung shutters with steel handles and steel peg stay doytailed at welded incl 2 Nos tower bolts 150 mm long for each leaf and 10 mm square bar grills at spacing as shown on drg welded to FI frame work,incl other fittings, hinges, handles tarred hold fast PCC blocks etc. including two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3
3mm thick sheet glass ordinary quality, and glazing with oil putty or wooden beads in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed by Engr-in-charge.
3mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
S&F aluminium handles, cast type, anodised of size 150 mm long, complete all as specified and directed.
S&F 200 mm size (length of bolt) aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed
S&F Steel locking bolts with mild steel electro galvanised plate and bright bolt not less than 10mm dia, 100mm size complete all as specified and directed.
S&F 300 mm size (length of bolt) aluminium alloy, anodised, sliding door bolt with hasp and staple ,(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F 2nd class hard wood small fitting such as cleats, brackets of any type,latch and hinge blocks,shaped door and windew stops and the like including all necessary labours articles n.exc 200 Cu.cm each complete all as specified and as directed
S&F in repairs 25mm dia powder coated aluminium anodised curtain rod with fixing brackets, stops, rollers, complete all as specified and directed.
Taking up or down 15mm bore dia steel tubing and connection, including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down 20mm bore dia steel tubing and connection, including cleaning for refixing or removal to store, complete all as specified and directed.
Steel water tubing, 15 mm bore dia, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc, complete all as specified and directed.
Steel water tubing, 20 mm bore dia, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc, complete all as specified and directed.
S&F vitreous china english type WC one piece (WC & flushing cistern) of size 645mm x 355mm x 725mm with 'S' trap including connection to trap and flushing pipe complete all as specified and directed. Make:- Juquar cat part No-CM-WHT-103851S or equivalent as approved by GE.
S&F vitreous china, wash hand basin, (Oval type white) of size 450mm x 300mm including 15mm boreCP pillar tap fancy type, brass CP waste coupling 32mm size with long screwed shank and fly nuts, PVC medium grade 32mm dia waste pipe, chain and plug, porcelain stopper , PVC connection 15mm dia, 450mm long with brass CP nuts and washers at both ends (fixed in repair), complete all as specified and directed.
S&F in repairs CP jet spray hygenic spray set with 15mm dia 1 mtr long tube acrylic type complete all as specified and as directed.
S&F in repairs stop valve, cast copper alloy, fancy type,chromium plated, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for 15mm bore iron pipe or for union complete all as specified & directed.
S&F in repairs CP soap dish fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed.
S&F in repairs pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' & 'Cold' with long screwed shanks and fly nuts, screwed for 15 mm bore iron pipe complete all as specified & directed.
S&F PVC connection suitable for 15mm pipe with PTMT nuts and washers for both ends of length 600mm long, complete all as specified and directed.
M&L pre-cast cement concrete type B-1 1:2:4 (20mm graded crushed stone aggregate) as in landings, cover slabs for man holes and similar articles, set in CM 1:6 complete all as specified and directed.
TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and directed by Engr-in-charge.
S&F 1000 Ltrs capacity rotational moulded polyethylene water storage tank , ISI marked (cylindrical vertical with closed top), double wall layer construction, hoisted and fixed in position complete all as specified in SSR Part-I, making connections including 20mm bore ball valve brass with polyethylene float and fly nut and dismantling existing water tank of any capacity and removing from site. complete all as specified and directed by Engr-in-charge.
S&F in repairs 20mm gun-metal, glove or gate valves, with iron wheel head, screwed both end for iron pipe and fixed, complete all as specified.
Taking down cement plaster including tiles of any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Rendering 10mm thick plaster in cement mortar 1:6 on fair faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 15 mm thick on stone masonry or other than fair faces of brick wall in cement mortar 1:4 finished even and fair without using extra cement, complete all as specified and directed.
Peparation of new plastered or unplastered surfaces of walls and applying two coats of plastic emulsion paint (interior emulsion) over priming coat including 2 to 3 mm in two coats of wall putty finished complete all as specified.
Preparation of new plastered or unplastered surfaces of wall and applying two coats of plastic emulsion paint (exterior emulsion) over one coat of primer including 2 to 3mm in two coats of wall putty finish, complete all as specified.
M&L for complete removal of existing treatment of walls and applying two coats of plastic emulsion paint (exterior emulsion) over primer coat including 2 to 3 mm in two coats of wall putty finished complete all as specified and directed.
M&L for complete removal of existing treatment of walls and applying two coats of plastic emulsion paint (interior emulsion) over primer coat including 2 to 3 mm in two coats of wall putty finished complete all as specified and directed.
Prepartion of new wooden surfaces of any description not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified.
Preparation of new steel surfaces of any description, over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
Taking up or down old 100 mm bore CI waste and vent pipes with fittings laid in trenches or fixed to wall including cleaning for refixing or removal from site, complete all as specified and directed.
Taking up or down old 75 mm bore CI waste and vent pipes with fittings laid in trenches or fixed to wall including cleaning for refixing or removal from site, complete all as specified and directed.
S&F 75 mm bore cast iron soil , waste and vent pipes (Sand cast), in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed.
S&F 100 mm bore cast iron soil , waste and vent pipes (sand cast), in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed.
S&F 100mm bore cast iron branch pieces, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F 75mm bore cast iron branch pieces, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F 75mm bore cast iron bend (any radius), diminishing pieces or tapers (larger bore measured), complete all as specified and directed.
M&L plain cement concrete,1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in surface channels or drains etc, complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins arches, pillers etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
M&L for brick Work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6, complete all as specified and directed.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type 60cm long , fixed to wall with CP brass screw and PVC rawl plugs, complete all as specified and directed.
Dismantling posts or struts (wood,steel or RCC) any section, including taking out embedded portion & making good disturbed ground, complete all as specified and directed.
Dismantling timber scantling work as in fillets, rails, posts, rafters, purlins, scantling etc under 40 sqcm in section complete all as specified and directed.
Taking down roof trussed, coupled rafter or trussed beam for clear span above 4.00m upto 8.00m, complete all as specified.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-290 (Gde E-165), complete all as specified and directed .
Demolition of cement concrete (un-reinforced) in ground floor and in pavings not exceeding 15 cm thickness (below or above ground level) complete, all as specified and directed.
All as per the description of serial item No. 03 above but except stones, complete all as specified and directed.
M&L for plain cement concrete, M-10 (Nominal Mix), type C-1 (using 20mm graded crushed stone aggregates) as in roof kerbs, mud stops, roof padding etc complete all as specified and directed.
TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia,complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in sub base complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc, complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness laid dry or laid dry and pointed in floors, aprons etc complete all as specified and directed
Fixing only machine pressed precast concrete interlocking paver block as in floor, path/apron etc of any shape and size as retrieved from dismantling complete all as specified and directed.
M&L for 60mm thick rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size (shape as approved bt GE) laid in path, porch, hard standing or flooring etc conforming to IS-15658-2006, M-35 grade complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed .
M&L 150mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in hard standings finishing the surface even & fair without using extra cement complete all as specified and directed.
M&L for aluminium dividing strips, 1.5mm thick and 38mm wide in width, inserted in position complete, all as specified and directed.
Removal of excavated material (soil) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified.
SCHEDULE 'A' PART-II Taking down carefully unserviceable Aluminium/Copper point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custody for taking credit (credit for above item should be made as per condition seperatly) and making good disturbed surfaces of walls, floor etc complete all as specified.
Taking down unserviceable sub main wiring of any size incl batten conduit earth wire etc and making good disturbed surfaces to match the existing surface complete all as specified.
Taking down unservecable TPN DB with MCB's of any make/capacity complete all as specified.
Taking down unservecable MCB DB SPN with MCB's of any make/capcity complete all as specified.
Point wiring for one 1.5 sqmm copper conductor cable (multi strand) FRLS PVC insulated unsheathed and incl PVC casing and caping of approriate size to be terminated in sunk cast iron pressed steel terminal boxes with all fitting such as Tee, connector, pieces, L-junction etc on joints including CI/MS/PVC sunk box of required size for mounting switches socket regulator etc with 3 mm thick plastic laminated sheet cover of adequate size for one light point controlled by one switch incl contionous 1.5 sqmm PVC insulated and unsheathed FRLSH multistrand copper conductor earth wire to common earth and connected to earth dolly, complete all as specified.
All as per the description of serial item No 131 here-in-before but for one fan point/Exhaust fan controlled by one, one way switch and regulator complete all as specified.
All as per the description of serial item No 131 here-in-before but for one bell point controlled by one, one bell push complete all as specified.
All as per the description of serial item No 131 here-in-before but for 3 pin socket outlet 5 amp independent board complete all as specified.
All as per the description of serial item No 131 here-in-before but for 3 pin socket outlet 5 amp same board complete all as specified.
All as per the description of serial item No 131 here-in-before but for 3 pin socket outlet 15 amp independent board with cable of size 2.5 sqmm in point wiring and 1.5 sqmm in contionous earth wire complete all as specified.
S & F switch piano flush type single pole one way 5 amp complete all as specified.
S & F socket outlet 3 pin 5 Amp flush type complete all as specified.
S & F switch piano flush type single pole one way 15 amp complete all as specified.
S & F socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified.
S & F bell push piano flush type single pole one way 5 amp 240 volt for electric bell complete all as specified.
S & F musical door bell AC 230 Volt single phase complete all as specified.
S & F electronic fan regulator flush mounting 230 volt dimmer step type 120 watt with switch having 5 step to regulate / control speed of ceiling fan complete all as specified.
S & F ceiling rose surface type 65mm x 50mm 3 terminal complete complete all as specified.
Supply and fixing LED box type tube light fitting suitable for 1x20W 4 FT complete with LED tube rod, fixed complete to wall/ceiling and PVC round/square block (02 Nos) of suitable size etc provided complete with flexible pipe of suitable size complete all as specified. Make:- Crompton Cat Part No DMLN1LT8-16 with tube Cat part No LT8-20-865-2 or equivalent.
Supply and fix decorative wall light fixture made up of Polycarbonate incl LED lamp 10 watt complete complete incl two core wire connection from ceiling rose to connector with flexible pipe of suitable size of all complete all as specified. Make:- Havells Cat Part No LHDL03160099 or equivalent.
Supply and fix batten holder with LED lamp 10W complete all as specified.
S&F Pressure die cast housing with epoxy power coated dark graphite grey colour finish prismatic polycarbonate cover with individual LED lenses. with 36 W LEDs as light source complete all as specified. Make:- Halonix Cat Part No. HLSLD-09-30-CWL-R or equivalent
S&F street light bracket made out of 32 mm dia GI light grade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 50 x 6 iron strip and nut bolts and washers, complete all as specified.
Taking down old unserviceable light fittings/Bulkhead fittings of any type and model complete and making good the disturbed surface complete all as specified.
M&L for sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of Single 6 Sq mm in PVC casing and caping of appropreate size including one SIngle core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sq mm as earth continuity conductor connected to commen earth and earth dully complete all as specified.
Supply and fix distribution board iron clad DB double door with IP-43 protection 415 V 3 Phase 50 HZ 4 Way complete with appropriate size of copper busbar and neutral link complete and incl cutting chasing to wall for fixiing DB and making good the disturbed wall to match with existing surface complete all as specified. Make:- Indo Asian Cat Part No 811840 or equivalent.
Supply and fix MCB distribution board sheet steel powder coated SPN 8 way acrylic body double door IP-42 protection with 200 Amp rated busbar 240 Volt complete all as specified.
Supply and fix MCB TPN 63 Amps 230 volts 'C' series complete all as specified.
Supply and fix MCB SPN 40 Amps 10 KA 230 volts 'C' series complete all as specified.
Supply and fix MCB SP 40 Amps 10 KA 230 volts "C" series complete all as specified.
Supply and fix MCB SP 6 to 32 Amps 10 KA 230 volts "C" series complete all as specified.
Supply and fix blanking plate for MCB/DB complete all as specified.
Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with top edge of the plate not less than 1.5 mtr below ground level and connected to galvanised iron earth lead wire 4mm (8 SWG) dia by means GI nuts, bolts & washers including PCC pit (1:2:4) type B 1 pre cast RCC cover slab of size 550 x 550 x 75mm thick using reinforcement with XPM weighting not less than 1.8 Kgs / sqmm with suitable handle, made of 12 mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with case iton funnel and wire mesh, 15mm bore light grade galvanised steel tubing upto 5 M length for drawing earth lead wire protection, common salt, charcoal etc complete all as shown in EP No 3 of SSR Part I and testing on completion.
Disconnecting/Taking down and refixing in servicible condition of electric water heater any type/ any capacity removing and cleaning the dust properly, painting with same colour good quality synthetic enemelled paint after preparing surface for painting incl refixing and making the connection and testing complete all as specified.
Disconnecting/Taking down exhaust fan of any size/any type, removing and cleaning the dust properly, painting with same colour good quality synthetic enemelled paint after preparing surface for painting oiling and greasing of bearing incl refixing and making the connection and testing complete all as specified.
Disconnecting/Taking down ceiling fan of size 1200/1400mm sweep removing and cleaning the dust properly, painting with same colour good quality synthetic enemelled paint after preparing surface for painting oiling and greasing of bearing incl refixing and making the connection and testing complete all as specified.
Taking down unservicible U/G cable after disconnecting from pole and Supply & laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 mtr in depth for foundation laying of under ground cable erecting of pole stay not exc 10 sqm on plain and not exc 1.5 m depth and getting out in any type of soil complete all as specified.
Returning, filling in (soil ) including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified.
Removal of excavated material (soil) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified.
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
Sub class “B” brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal, to length of the brick, complete all as specified and directed.
Material and labour for GI tubing (light grade) with all fitting laid in trenches or along pole/bldg or under road crossing and protection pipe or fixed alongwith wall/pole with necessary clamp nut bolt and washer bore of pipe 40mm complete all as specified.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .