| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.6 LAccepted-AOC 137 MODERN COMPLEX ZIRAKPUR DISTT MOHALI PB | ZIRAKPUR | MOHALI | PUNJAB | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹42.8 L+₹1.1 L (2.73%)Rejected-Finance 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | L2 | Rejected-Finance Being not L1. | |
| 3 | L3₹45.4 L+₹3.8 L (9.03%)Rejected-Finance 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L3 | Rejected-Finance Being not L1. | |
| 4 | L4₹45.9 L+₹4.3 L (10.2%)Rejected-Finance 164 SECTOR 21A CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L4 | Rejected-Finance Being not L1. | |
| 5 | L5₹46.5 L+₹4.8 L (11.5%)Rejected-Finance | L5 | Rejected-Finance Being not L1. |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
17 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) MC Chandigarh
GE (AF) MC Chandigarh
PROVN OF CERTAIN SANCTIONED WORKS AT 3BRD AF STATION CHANDIGARH UNDER GE (AF) MC CHANDIGARH
2022_MES_508182_1
GE (AF) MC /CHD-79/2021-2022
Open Tender
Civil Works
Item Rate
270 days
CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) MC Chandigarh
₹86,000
Yes
30 Mar 2022
15 Feb 2022
19 Mar 2022
15 Feb 2022
17 Mar 2022
4 Mar 2022
60 days
Amount
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft and loose soil complete all as specified and directed .
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation , filling and mass concrete all as specified and directed .
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm in any type of soil complete all as specified and directed .
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed .
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for brick work with fly ash bricks straight or curveted in plan exc. 6mtr mean radius with old size bricks in CM 1:6 complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions (Square, rectangular or polygonal on plan), for fair finished flat surfaces complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) in roof beams, cantilevers, bressummers & lintels complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) in slabs supported on walls ,beams, chajjas and columns in floors ,roofs ,landings,balconies canopies ,dek slabs and in shelves and the like complete all as specified and directed.
M&L for use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams;and similar work for flat surfaces complete all as specified and directed.
M&L for use & waste of formwork to sides and soffits of floor and roof beams, chajjas ,lintels ,cantilevers ,shelves including supports ,overhangs and similar work , for rough finished flat surfaces complete all as specified and directed.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) for rough finished of concrete flat surfaces complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia & over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and building with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as item No. 15 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for broken stone or boulder of gauge n exc. 63 mm in hardcore, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface concrete complete all as specified and directed.
M&L for 75 mm thick PCC type D-2 1:4:8 (40 mm graded stone aggregate) typeD-2 as in sub base complete all as specified and directed.
M&L for 75 mm thick PCC type C-2 1:3:6 (40 mm graded stone aggregate) type C-2 as in plinth protection complete all as specified and directed.
M&L for rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:3 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10 mm thick Vitrified tiles in light shade( square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including screed bed or bedding layer of 15mm thick in CM (1:6) , complete all as specified and directed .
All as per ser item No 23 but in vertical surfaces such as skirting, dados and risers to steps etc over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for two coats of Oil Bound Distemper over a coat of alkali resistant primer over a thin layer of wall putty including preparation of plastered or unplastered new wall surfaces, complete all as specified and directed .
M&L for two coats of Oil Bound Distemper over a coat of alkali resistant primer over a thin layer of wall putty including preparation of plastered or unplastered new ceiling surfaces, complete all as specified and directed .
M&L for two coats cement base paint on newly plastered, undecorated surfaces of walls including preparation of new plastered surfaces complete all as specified.
M & L for Rendering 10mm thick on concrete surfaces in cement mortar 1:3 with liquid water proofing compound (200ml/50Kg bag) finishing even and fair without using extra cement as in under layer of roof treatment at any height complete all as specified and directed. Note : Water proofing compound shall be paid measured and paid seperately.
Supply only Liquid water proofing compound complete all as specified and directed .
M&L for applying oil bound bituminous primer @ 0.20 Kg/Sqm and providing 4mm thick, APP modified water proofing membrane reinforced with non woven polyester matt having softening point not less than 150 degree centigrade having tensile strength of 650 N/Sqcm in longitudinal and transverse directions respectively of the reinforcement tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap, applying a coat of blown hot bitumen grade 90/10 over the membrane @ 1.2 Kg/Sqm complete all as specified and directed.
M&L for 40mm thick brick tiles laid over and including 15mm thick screed bed in CM 1:6 , joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed.
M & L for powder coated aluminium (minimum thickness of polyester powder coating 50 micron) aluminium work for fixed portion and shutters of doors, sliding door, cabin work (any track)/openable windows, ventilators, partitions and sliding/openable with extruded built up standard tubular sections/appropriate Z sections and other sections conforming to IS-733 and IS:1285 fixed with raw plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions at top, bottom and sides with required EPDM rubber/Neoprene gasket roller etc aluminium section shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/gauged/paneling, CP brass/stainless steel screws, complete all as specified and directed.
M&L for aluminium composite panel sheet of colour/shade and pattern approved by GE of 4mm thickness which consists of 3 mm thick thermoplastic core of anti-toxic LDPE sandwiched between 2 skins of 0.5 mm thick aluminium foils with outer surfaces finished with 30 µ PVDF & inner surface finished with a thin coat of polyester paint, fixed in panels to aluminum frame including all necessary frame work or powder coated snap beading and rubber gasket complete all as specified and directed. Make: Alstone/ Alex panel/ Armstrong/ Eurobond
S&F 4.8mm thick plain glass exc 0.5 sqm in each pane fixed to aluminium door/ windows and iron frame complete all as specified and directed..
S & F aluminium anodized decco grills as per sample kept in GE office complete all as specified and directed. Note :- Tenderer should visit the sample room before quoting the rate
S&F Aluminum anodized barrel tower bolt of extruded section 150 mm long complete all as specified and directed.
S&F brass Mortice lock verticle type 100mm size, 4 lever fixed in aluminium shutter complete all as specified and directed.
S&F door closer aluminium body (die Cast) hydraulically regulated designation No 3 universed type cast iron body suitable for door shutters of 851 to 1000mm in width complete all as specified and directed.
S&F door stopper 100 mm size of aluminium alloy body with rubberised bottom complete all as specified and directed.
S&F 200 mm size Powder coated(any tint) aluminium "American Handle" fixed to aluminium door with suitable screws complete complete all as specified and directed.
Material and labour for 12mm thick glass reinforced gypsum (GRG) ceiling tiles of size 595 x 595mm of approved design fixed with powder coated (powder coating on web bottom only) GI grid consisting of main Tee section of size (25mm x 30mm), cross Tee section of size (15mm x 23mm) and powder coated GI wall angle of size (20mm x 20mm) suitable for mounting tiles of 595 x 595mm with 4mm dia GI wire suspender, GI adjustable rod of 4mm dia with butterfly level clips, spaced at 1200mm c/c along main T, bottom exposed width of 15mm of all T-section shall be centre black prepainted with polyester paint and having a load bearing capacity of 12Kg/Sqm, complete all as specified and directed. Make : Diamond Brand TM/ Dexune/Everest
M&L for MS Plates (plain or chequered) cannels ,square cut or notched for duct cover confirming to FE 410-W(Gde-E-250 quality -A) complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer incl preparation new steel or iron surfaces exc 10cm width or girth complete all as specified and directed.
M&L for 6 mm thick Epoxy PU based anti static flooring complete all as specified and directed and as per manufactures instruction consisting of following steps / stages :- (a) Surface cleaning : cleaning of surface free from dust, dirt moisture & all foreign material front he floor. All floor is to be cleaned by means of scrubber. Acid itching and water wash is done. then the oil /grease is removed from the floor using hot compressed air blasting machine for floor cleaning all mechanized equipments are to be used like scrubbers, sanders, hot blowers, vacuum cleaners, moisture test machine etc. (b) Raking out old all decayed /damaged existing sealing compound from the joints of size of 8 mm to 40 mm wide and 45 mm to 50 mm average depth and cleaning the joints thoroughly by removing dust, dirt, loose and foreign material by appropriate hand tools such as chisel, hammer of L hooks, scraping out the exiting sealing joints, grinding or cutting the inner sides of the joints by diamond cutter to have perfect plane sealant free surface without breaking the edges, removing dust by power blower/compressed air and removing rubbish material outside MOD land including necessary preparation of surfaces by cleaning the sides and bottom as given below to make the exiting joint 10mm wide. Note: Any variation in size of joint is deemed to be included in quoted rate. (c) Applying primer coat of two component epoxy primer followed by application of pre-batched ready to use epoxy mortar in the grooves. The mortar shall be filled on the both sides of groove to bring the joint to 10 mm width & inserting closed cell, medium density cross linked polyethylene foam back up rod of 10 mm dia and filling the PU based sealing compound matching the same colour with PU flooring.
(d) Primer : Providing and applying low viscous epoxy primer having a volumetric ration of mixing of resin and hardener in equal volumes to provide a DFT of around 200 microns. (e) Screed: Providing and applying self leveling screed with polymer to aggregate ratio not exceeding 1:4 by trowel to the desired thickness of 3700 microns the layer is desecrated by spike roller to dislodge air pockets. (f) Copper Tape : Providing and fixing 100 microns thick, self adhesive (conductive type) copper tape to ensure quick transfer of charge including connecting copper wire / tape and earthing etc. required to get the desired result. The spacing of copper tape shall be approximately 5 m c/c both ways Make:3M or Equivalent. (g) Conductive Primer: Providing and applying PU (polyurethane) based conductive coat having a volumetric ratio of resin and hardener in 4:1 to yield a DFT of 100 microns. Note: cost of joint filling shall be deemed to be included in the item. (h) PU Self leveling top coat : Providing and applying PU based conductive self \leveling top coat containing anti stats to yield a thickness of 2000 microns and surface resistivity which will not exceed 10 ohms. The cured surface shall be tested with Mega ohm Meter as per ASTM F-150, to check the readings as per the design. (j) The entire work / application shall be done through manufacturer only. Make : CIPY/SIKA/BASF/APURVA/ASIAN
Demolition of reinforced cement concrete in any position at any height (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars etc, but exluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Taking down cement plaster on brick wall including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area not exc. 1.5 sqm each and removing from site complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) areaexc. 1.5 sqm but n.exc 4.0Sqm each and removing from site complete all as specified and directed.
Dismantling of kota stone slabs and tiles of any thickness in flooring etc complete all as specified and directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish of the premises complete all as specified and directed.
S & F vitrified dark shade/Double charged/ultra charged coloured ceramic tiles 10mm thick area of each tile exc 0.42 Sqm but not exc 1.00 Sqm in floors and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for glazed ceramic coloured first quality tiles of size 450 x 350 x 7mm thick as in skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed
M & L for brick with fly ash brick straight or curved on plan to any radius in half brick thick wall built in CM (1:4) complete all as specified and directed.
M & L for complete removal of existing surface of wall and providing two coat of oil bond distemper over a thin layer of putty over a coat of primer and rubbing with sand paper at any height of building including necessary scaffolding, ladder, formwork etc complete all as specified and directed.
S & F float glass tinted 5mm thick fixed in aluminium frame with aluminium powder coated snap beading including rubber/EPDM gasket, complete all as specified and directed.
S & F 100mm size aluminium anodised powder coated butt hinges complete all as specified and directed
S&F brass Mortice lock verticle type 100mm size, 6 lever fixed in aluminium shutter complete all as specified and directed.
S&F Aluminum anodized barrel tower bolt of extruded section 200 mm long complete all as specified and directed.
S&F 180 mm size Powder coated(any tint) aluminium "American Handle" fixed to aluminium door with suitable screws complete complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
M&L for surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as specified and directed
M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in floor and finish rough to receive the floor tiles concrete all as specified and directed .
M&L for 100 mm thick PCC 1:4:8 (40 mm graded stone agg) typeD-2 as in sub base complete all as specified and directed.
M & L for Machine cut kota stone slab flooring 20-25 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish laid over and including 20 mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and directed.
M & L for Machine cut kota stone slab in riser of steps, skirting, dado 20 to 25 mm thick over & including 10 mm thick rendering in CM 1:4 laid & jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to mirror finish including complete all as specified and directed
S&F pressed steel frame for doors with one or more rebates of size 105 x 60mm made with steel sheet of 1.25mm thickness in and including necessary fixing lugs, hinges lock strike plate including backfill of chowkhat with PCC 1:3:6 type C-0 using 12.5mm stone aggregate, complete all as specified & directed .
Supply and fixing, 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, chemically treated against termite infestation, complete all as specified and directed
Supply and fix, Aluminium alloy, anodised, sliding door bolts 200mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 12mm dia, complete all as specified and directed.
Supply and fixing, aluminium handle 150mm long, complete all as specified and directed.
Material and labour for preparation of new wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Supply and fixing steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
Supply and fix, plain sheet glass 4mm thick, ordinary quality, not exceeding 0.50Sqm in each pane fixed to aluminium door/window and iron frame including aluminium powder coated snap beading and rubber gasket, complete all as specified and directed.
Supply and Fixing, Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed.
Supply and Fixing, Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed.
S&F Pre painted Coloured Galvalume roofing system sheet 0.50 mm thick, corrugated sheet having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws, complete all as specified and as directed. Note:- (i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation. (ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides. (iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer. (iv) The contractor shall produce purchase vouchers for each lot for verification of Engineer-in-Charge. Make:- M/s Tata Blue scope/Jindal/Bhusan/JSW
S&F Pre painted Coloured Galvalume roofing system sheet 0.50 mm thick, plain sheet having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws, complete all as specified and as directed. Note:- (i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation. (ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides. (iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer. (iv) The contractor shall produce purchase vouchers for each lot for verification of Engineer-in-Charge. Make:- M/s Tata Blue scope/Jindal/Bhusan/JSW
Supply and fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 22.5cm but n.exc 30cm long and 16 to 20mm dia complete all as specified and directed.
E&M Works for Fire Alarm System S&F Fire alarm control panel complying with BS EN 54 single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified and directed.
S&F detectors complying with and type certified to EN 54 addressable type multisensor detector with heat and smoke combination photo electric/optical with base and with self built intelligence as per IS-11360, complete all as specified and directed.
Supply, installation, testing and commissioning of explosive proof analog addressable manual pull station pull type and resettable with black plate complete all as specified and directed.
Supply, installation, testing and commissioning of addressable electric sounder cum strobe complete all as specified and directed.
S&F short circuit isolator, complete all as specified and directed.
S&F remote response indicators, complete all as specified and directed.
S&F PVC insulated heavy duty FRLS copper conductor 1.5Sqmm 2 core, complete all as specified and directed.
S&F 20mm dia bore stove enameled steel conduit ISI marked with required accessories such as joint clamps, junction box, elbow etc to mount detectors, complete all as specified
E&M Works for Server Room & building No. P-141 Supplying, laying, testing, connecting and commissioning LT cable size 16Sqmm, 4core, 1100 Volts grade heavy duty XLPE insulated armoured with aluminium stranded conductor with suitable size cable glands, crimping type cable lugs etc, complete all as specified and directed.
Material and labour for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supply and laying precast concrete cable cover, class LV type 1 made of M-30 using 20mm graded stone aggregate, flat of size 250mmx150mmx40mm, complete all as specified and directed.
Supply, installation, testing and commissioning of high wall mounted split type AC 2TR operated on 410A/407C refrigerant gas not less than 3 star rated with cordless remote, operated on single phase AC supply 230 volts including necessary making holes, cutting chases for refrigerant pipes, connection of cable in brick wall, necessary MS bracket for fixing outdoor/indoor units made out of structural steel section, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and making good disturbed surface and matching with the existing surface including PVC heavy duty conduit pipe 20mm laid concealed in brick wall from inner unit to outside, including necessary refrigerant pipes and also including PVC insulated copper flexible cable 4Sqmm 3 core of required length from inner unit to outer unit and for socket point of voltage stabilizer etc, complete all as specified and directed. Makr:- LG/Samsung/Hitachi/Voltas
Supply, installation, testing and commissioning of voltage stabilizer single phase 5KVA capacity operated on single phase supply, designed for input voltage between 140 volts to 280 volts and output voltage stabilized at 230 V +/- 8% including necessary connection etc complete all as specified and directed. Make:- V-guard/AE/Volina/Voltamp
Supply and fixing sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB 32 Amp complete all as specified and directed.
Material and labour for Sub Main Wiring with two run single core 4Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including stove enamelled steel conduit of 20mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 4Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity and making good disturbed surface, complete all as specified and directed. Note:- Two run of 4Sqmm (phase+ Neutral) + One run of 4Sqmm for earth wire shall be measured as one RM.
Supply and fixing 15mm bore tube medium grade steel water tubing with and including all GI fittings laid in trenches or fixed to wall complete all as specified and directed.
M&L for Point wiring (Concealed) in and including rigid stove enameled steel conduit not less than 20mm dia suitable as per site requirement including cutting chases for conduits, sinking for boxes for concealed conduit wiring using stranded copper conductor FRLS cable of size 1.5 Sqmm, PVC insulated Unsheathed complete including flush type metal box modular type suitable for fixing of modular switches, sockets, fan regulators etc with brass screws, cup washer and including 1.5 sqmm PVC insulated stranded copper conductor FRLS cable as continues earth wire connected to common earth dolly for one light/fan/bell point complete all as specified and directed.
All as per ser item No 97 but with 4Sqmm copper conductor for 15Amp independent modular socket complete all as specified and directed.
S&F modular switch, 1 module single pole one way 6 Amp complete all as specified and directed . Make:-Indo Asian/SSK/Anchor
S&F modular switch, 1 module single pole one way 16 Amp complete all as specified and directed. Make:-Indo Asian/SSK/Anchor
S&F modular Socket outlet 3 pin 6/16Amp multipurpose, modular type, 2 module 240 volt complete all as specified and directed. Make:-Indo Asian/SSK/Anchor
S&F Ceiling rose surface Bakelite 65 x 50 mm two to three terminals complete all as specified and directed . Make:- CONA/SSK/Anchor
S&F LED slim flat panel 36W having lumen output more than 3200 lumens suitable for false ceiling of cut out size 2'x2' including making connection complete all as specified and directed .
S&F MCB DB TPN 04 way steel sheet phospetised powder painted with 200Amps rated bus bar with IP 43 protection 415V neutral link, earth bar and din rail double door complete all as specified and directed .
S&F MCB Single pole 5 to 32 Amp, complete all as specified and directed .
S&F MCB TPN 63 Amp complete all as specified and directed .
S&F wall mounted air circulator metal body fan 450mm sweep heavy duty, AC single phase 230/240 Volts fixed on wall complete including necessary connection with 3 core copper conductor of size 1.5Sqmm from ceiling rose, complete all as specified & directed .
S&F ceiling fan 5 star rated 1200mm sweep with down rod of required length including necessary connection with 3 core copper conductor of size 1.5Sqmm from PVC terminal block, complete all as specified & directed .
Taking down and re-shifting of exhaust fan with louver shutter of any sweep AC single phase 230/240 volts including necessary connection with 3 core copper conductor of size 1.5Sqmm from ceiling rose and cutting hole in brick wall and making good to disturbed surface complete all as specified & directed .
Material and labour for Chemical earthing complete with copper earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 3.5 m deep below ground level) with top edge of plate not less than 2.5 m below normal ground level, earth pit filled with Magnesium Sulphate (MgSO4) 15 cm all around the plate including connection with and including copper strip 32 x 6 as earth lead fixed by means of copper nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc , complete all as directed and specified. Note : The earth value/result must be less than 1.0 ohms.
S&F terminal block made out of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw, complete all as specified & directed .
S&F cable tray stainless steel powder coated of size 300mmx54mm in 03 metre length, complete all as specified & directed .
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI wire 4 mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 15 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc , complete all as directed and specified. Note : The earth value/result must be less than 5 ohms.
S&F copper strip 20x3mm as earth continuity conductor or main earthing lead fixed to wall on insulator or recess or chases or buried in ground or drawn in and including conduit/pipe or fixed to wall or any other indicated situation to connect the equipment from test point, complete all as specified & directed .
S&F LED flood light fitting 60W to be fixed to channel and as required to be mounting bracket on wall/roof to suit the opening of the fitting with FI clamps, nut, bolt and washers of suitable size including making connection , complete all as specified & directed . Make:- Crompton/C&S/Havells
S&F LED light fittings 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilin rose , complete all as specified & directed . Make:- Crompton/C&S/Havells
S&F MCB DB SPN 240V 8 way steel sheet phospetised powder painted with 200Amps rated bus bar IP 43 protection 415V neutral link, earth bar and din rail double door complete all as specified & directed . , complete all as specified & directed .
S&F MCB Single pole and neutral 32 Amp complete all as specified & directed .
Material and labour for Sub Main Wiring with two run single core 6Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including stove enamelled steel conduit of 20mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 4Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity and making good disturbed surface, complete all as specified and directed. Make of cable:- Plaza/Finolex/Havells/Polycab Note:- Two run of 6Sqmm (phase+ Neutral) + One run of 4Sqmm for earth wire shall be measured as one RM.
Material and labour for Sub Main Wiring with Four run single core 10Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including stove enamelled steel conduit of 20mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including Two run of continuous multi stranded copper conductor 6Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity and making good disturbed surface, complete all as specified and directed. Make of cable:- Plaza/Finolex/Havells/Polycab Note:- Four run of 10Sqmm + Two run of 6Sqmm for earth wire shall be measured as one RM.
Supplying, laying, testing, connecting and commissioning LT cable size 16Sqmm, 3.5core, 1100 Volts grade heavy duty XLPE insulated armoured with aluminium stranded conductor with suitable size cable glands, crimping type cable lugs etc, complete all as specified and directed. Make:- Havells/Polycab/KEI
S&F MCB TPN 40 Amp complete all as specified and directed .
S&F MCCB 4 pole, 415V, 50Hz, 16KA, 63Amp complete all as specified and directed .
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 25 x 4 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc , complete all as directed and specified. Note : The earth value/result must be less than 5 ohms.
S&F copper strip 25x3mm as earth continuity conductor or main earthing lead fixed to wall on insulator or recess or chases or buried in ground or drawn in and including conduit/pipe or fixed to wall or any other indicated situation to connect the equipment from test point, complete all as specified & directed .
S&F 4mm dia GI wire as earth continuity conductor or main earthing lead fixed to wall on insulator or recess or chases or buried in ground or drawn in and including conduit/pipe or fixed to wall or any other indicated situation to connect the equipment from test point, complete all as specified & directed .
S&F GI pipe light grade 40mm dia for protection of LT cable, complete all as specified & directed .
Supplying, laying, testing, connecting and commissioning LT cable size 25Sqmm, 2core, 1100 Volts grade heavy duty XLPE insulated armoured with aluminium stranded conductor with suitable size cable glands, crimping type cable lugs etc, complete all as specified and directed. Make:- Havells/Polycab/KEI
Material and labour for Sub Main Wiring with two run single core 2.5Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including stove enamelled steel conduit of 20mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 1.5Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity and making good disturbed surface, complete all as specified and directed. Note:- Two run of 2.5Sqmm + One run of 1.5Sqmm for earth wire shall be measured as one RM.
Material and labour for Sub Main Wiring with two run single core 1.5Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including stove enamelled steel conduit of 20mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 1.0Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity and making good disturbed surface, complete all as specified and directed. Note:- Two run of 1.5Sqmm + One run of 1.0Sqmm for earth wire shall be measured as one RM.
Supply and fixing T-5 4ft tube light fittings with LED tube rod 4ft 20W operating on voltage 140V to 270V having lumen output >= 2000 lumens, efficiency 10lm/W, CRI>80, THD<20% and PF >0.90, colour temperature cool day light, having life upto 25000 burning hours with PC diffuser including making connection , complete all as specified and directed.
Note:- Amount of credit of Rs. 4850.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
Anil Kumar Gupta
KUMAR AND COMPANY
MS SACHDEVA BUILDERS
shree balaji builders
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .