Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.9 L+₹91,915.59 (7.07%)Rejected-Finance CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹14.0 L+₹1.0 L (7.97%)Rejected-Finance SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹14.9 L+₹1.9 L (14.5%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹15.1 L+₹2.1 L (16.2%)Rejected-Finance 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | L5 | Rejected-Finance Being L5 |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
31 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R AND D Chandigarh
Garrison Engineer I R and D, DIHAR Base Lab, Ground Floor, Near 3 (BRD) AF Stn, Industrial Area, Ph-II, Ramdarbar, Chandigarh
SUPPLEMENTARY REPAIR AND MAINT OF PERIMETER SECURITY LIGHT,LT/HT OVER HEAD LINES, LT POLE BOXES, LT UG CABLES INCLUDING CONNECTED WORKS AT TBRL RANGE RAMARH
2024_MES_635419_1
GE I R AND D/CHD-93/2023-24
Open Tender
Civil Works
Item Rate
180 days
Ramgarh
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandigarh
₹46,000
Yes
13 Apr 2024
2 Jan 2024
3 Feb 2024
2 Jan 2024
31 Jan 2024
17 Jan 2024
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 m in depth and not exceeding 1.5 m wide for laying of cables, erection of poles,struts, stays etc and getting out complete all as specified and directed .
All as per serial item no 1.00 above but depth exceeding 1.5 metre and not exceeding 3 metre -ditto
Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested, poles,stays,struts have been erected and tested complete all as specified and directed .
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed .
Material and labour for HDPE Double Wall Corrugated pipe of size 63mm to 90 mm outer dia confirming to IS:14930 Part-II including necessary pipe fittings such as couplers, end caps, bend etc. fixed to wall/roof /pole/trench as required with suitable clamps for cable protection complete all as specified and directed .
Demolition of concrete (coping of PCC/GI pole/Road) of any description and in any position complete all as specified and directed .
Material and labour for Plain Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles,earth pit ,including provision of necessary form work, finishing even and smooth without using extra cement complete all as specified and directed .
Supply and Install in replacement octaganol hot dipped galvanised street light poles with single bracket of length 1.5 m for mounting of street lights of height 10 Mtrs, top dia 75mm and bottom dia 155mm , Sheet thickness 3mm incl Base plate of size 240mm x 240 x 16mm and foundaation bolts 4 x M 24750mm, PCD 275 mm,Having door and window for connections, HDPE flexible pipe of suitable size for passing of cables below base plate complete incl excavation and RCC foundation as per recommendation of Pole manufacturer incl connections of cable with proper thimbles complete all as specified and directed .
Supply and fixing foring in replacement of street light bracket arm fabricated out of 40 mm dia GI tubing light grade 1.5 m long bend to shape fixed to pole with 2 pair of suitable size clamps of fitted with suitable size nuts, bolts washers incl one coat of paint complete all as specified and directed .
PCC 1:4:8 (nominal mix) type D-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-12 using 40 mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed.
Material and labour for GI pipe of size 40mm bore, light grade for protection to cable from coping to loop-in-loop out Jn box fixed to street light pole including necessary fixing complete all as specified and directed.
Supply & laying in replacement of UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 50 Sqmm 3.5 core laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. (Note: (i) Execution/earthwork cable protection pipe and cable joint shall be measured and paid for separately.)
All as per serial item no 13.00 above but of cross sectional area 25 Sqmm, 3.5 core -ditto-
All as per serial item no 13.00 above but of cross sectional area 16 Sqmm, 4 core -ditto-
All as per serial item no 13.00 above but of cross sectional area 10 Sqmm, 4 core -ditto-
All as per serial item no 13.00 above but of cross sectional area 10 Sqmm, 2 core -ditto-
Supply and fixing for cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 16 to 50 sq mm complete all as specified and directed .
Material and labour for cable joint termination junction box PVC body housing of size 200x160x98 mm suitable for housing and including 100 amps rated aluminium bus bar, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tubular pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 to 10 amps MCB, SP, 240 volt for street light supply complete all as specified and directed .
Supply and fixing in repairs LED Post top lantern of 1X20Watt with die cast aluminium spigot and lid cover, high efficient LEDs and clear acrylic cover IP-65, complete all as specified and directed . Make : Havells / HALONIX/Crompton/Bajaj.
Supply and fixing in repair outdoor bollard light 8 watt LED 4000K Cone series acts as a imposing street furniture.The elegant yet minimalsitic design acts a silent observer and giving light, diffuser at the upper portion acts a beacon of path guidance in a landsacpe environment suitable for operation on 240V, 50Hz single phase including necessary PCC work, nut, bolts, washers etc and accessories required for mounting lights complete all as specified and directed . Cat No- CONEBLS8WLED83OPSYTOPC of Make -Havells , Bajaj/philips/HALONIX
Supply and fixing in repair of 45W LED street light with pressure die cast aluminium housing, high power LED street light with heat resistant ,toughened glass with lense and driver to make it IP-66 degree of proction, Individual LED's must have lenses for better throw across & along the road, with system luminaire efficiency of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 5 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V should be provided. Over voltage proction should be there after 250 V +/- 10%. The manufactures logo must be embossed into the housing of the luminaire. Manufactures to provide LM80 report from source manufacturer and should have adequate testing facilities approved by ministry of science or any other Govt of India lab to provide LM79 report, including all connections complete all as specified and directed . Make -Orient/ Havells/philips/HALONIX
Patroling of all type of street lights at perimeter road , inside / ousides of zones & md accn etc to carry out repair of defective / LED street light from the LT poles with the help of hydraulic crane (VMTL) once in a week and give the report on daily basis to concerned Engr-in-Charge including of all sunday and holiday complete all as specified and directed
Supply and fixing in repair for energy saving & environmental friendly long life LED street light 60 watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection, impact resistance of IK07 & 10 KV external SPD and electronic driver of 60W LED 5700K complete all as specified and directed. Cat Part No. LSFT-060-C of Make:- Orient/Havells/Philps/HALONIX
Supply and fixing in repair for energy saving & environmental friendly long life LED street light 70 watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection, impact resistance of IK07 & 10 KV external SPD and electronic driver of 70W LED 5700K complete all as specified and directed. Cat Part No. LSFT-070-C of Make:- Orient/Havells /Philps/HALONIX
Supply and fixing in repair for energy saving & environmental friendly long life LED street light 90 watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection, impact resistance of IK07 & 10 KV external SPD and electronic driver of 90W LED 5700K complete all as specified and directed. Cat Part No. LSFS-090-C of Make:- Orient/Havells /Philps/HALONIX
Supply and fixing in repair energy saving & environmental friendly long life Inverter LED street light 60 watt with battery back up auto On/Off /DIMM proper fuctioning made up of pressure die cast housing with toughned glass and individual high power LEDs , IP66 protection and electronic driver of 60W LED 5700K complete all as specified and directed. Cat Part No. LED SL INVER-ML04-60-CWL-INV-RTC-R of Make:- HALONIX /Orient/Havells/Philps
Supply and fixing in repair new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 flood light luminaire 70 watt with high power LEDs as light source JETA NEO 50 and making necessary connections complete all as specified and directed. Make:- Orient/Havells /Philps/HALONIX
Supply and fixing in repair new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 flood light luminaire 100 watt with high power LEDs as light source JETA NEO 100 and making necessary connections complete all as specified and directed. Make:- Orient/Havells /Philps/HALONIX
Supply and fixing in repairs power contactor, type CN3 25F, four pole, 40Amp, 440 volt , Auxilary coil voltage 230 Volt complete all as specified and directed,
Supply and fixing in repairs power contactor, type CN6 95F, four pole, 125Amp, 440 volt , Auxilary coil voltage 230 Volt,complete all as specified and directed
Supply and fixing in repairs street light timer panel 3 phase 4 pole astronomical prewired with power contactor 32 Amps 3 pole, MCB 40 Amps TPN suitable for street light including all accesories complete all as specified and directed. Cat part No IHXTS0306A of Make : Havells / L&T/Legrand/Indoasian
Supply and fixing PVC insulated and weather proof twin core copper multi stranded conductor cable 2.5 Sqmm size as required length for replacing unserviceable cable for street light where ever found unserviceable and required from over head conductor or junction box to street light connector of Street Light fittings complete all as specified and directed
Material and labour for replacement of service cable 6 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular complete all as specified and directed
Material and labour for replacement of service cable 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular complete all as specified and directed
Material and labour for replacement of Stay assembly complete with MS stay plate of size 300x300x6mm thick, stay rod 16mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I of 1991 or complete all as specified and directed ( Excavation, PCC, say wire and loop type insulators shall be measured and paid for separately).
Material and labour for replacement of Galvanized stay strand of size 7/2.24 mm including taking down old stay of any size as and where required to replace and any description complete all as specified and directed
Material and labour for replacement of Loop type insulator large size with overall dimensions 90x140mm with clearance of hole 25.5 mm vitreous white brown or green complete as and where required to replace complete all as specified and directed
Complete removal of old paint from the steel tubular pole of 09 mtr height without removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative white and black strips of 30 cm height each, including one coat of aluminium paint to the remaining part of pole (i.e above 1.50 mtr height) and its cross arms, bracing, support and all steel members complete all as specified and directed.
Jai Maa Electrical Works
M/s Friends Engineering Works
M/s Shiksha Enterprises
Alpha Engineers and Builders
CHADHA ENGINEERS
R D Bansal
KISHORE ENTERPRISES
Bharat Enterprises
M/s Shakti Electric Works
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .