| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹10.0 L+₹58,938 (6.30%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹10.4 L+₹1.0 L (10.8%)Rejected-AOC 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹21,200
Closing Date
22 Feb 2021, 6:00 pmClosed
CWE AF JODHPUR
HQ CWE AF JODHPUR
Repair and Maint to Air conditioning and other certain misc EM nature works at AF Stn Jodhpur
2021_MES_409031_3
85871/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
GE AF JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF JODHPUR
₹21,200
Yes
9 Apr 2021
9 Feb 2021
24 Feb 2021
9 Feb 2021
22 Feb 2021
9 Feb 2021
Amount
Service and repair of existing installed temperature and humidity monitoring system at AF station Jodhpur (Wireless SCADA based temperature and Humdiity monitoring system ) ( MAKE: CIMCON) of air conditioning plant installed at "AC Plant No. 5,6&7/ MES office" at Domestic area Air force station Jodhpur by one factory trained Technician/ Software Engineer. The scope of work includes carrying out complete maintenance/ servicing/ repairs as required of all the above sub systems viz. iRTU based control panels (with all the accessories), RTD sensors, Humidity sensors, comunication pannels ( with all its accessories) Humdity indicator, Temperature indicator, SCADA system etc. (with all its accessories), complete all as specified and directed by Engr-In-Charge. Note :- (i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under respective items of shcedule 'A'/BOQ and shall be provided as per existing make at site. (ii) Repair / Maintenance to be done by authorised OEM only.
Supply Only in replacement of 24 V DC Power Supply Unit of iRTU all as directed by Engr-in-Charge.
Supply Only in replacement 12/5 V DC Power Supply Unit of iRTU all as directed by Engr-in-Charge.
Supply Only in replacement ARM 7 CPU card of RTUall as directed by Engr-in-Charge.
Supply Only in replacement Analog and Digital I/O Card of RTU all as directed by Engr-in-Charge.
Supply Only in replacement AI/DI Termination PCB of RTU all as directed by Engr-in-Charge.
Supply Only in replacement Display and Keyboard of RTU all as directed by Engr-in-Charge.
Supply Only in replacement 6V /4 AH Battery (Each Panel 2Nos.) all as directed by Engr-in-Charge.
Supply Onlyin replacement Under and Over voltage Protection Relay with Auto recovery feature. all as directed by Engr-in-Charge.
Supply Only in replacement Wireless GSM/GPRS modem for GSM/GPRS communication all as directed by Engr-in-Charge.
Supply Only in replacement High Gain Antenna for GSM communication all as directed by Engr-in-Charge.
Supply Only in replacement RTD sensor for the room temperature measurement all as directed by Engr-in-Charge.
Supply Only in replacement Humidity sensor with signal converter for the room Humidity measurement all as directed by Engr-in-Charge.
Supply Only in replacement Humidity / Temperature Indicator with TPS re-transmissionn system all as directed by Engr-in-Charge.
Supply only in replacement 2 core copper conductor of size 1.5sqmm FLEXIBLE cable complete all as directed by Engr-in-Charge.
Upgradation of Existing Desktop monitoring SCADA system with cloud monitoring SCADA software and its hosting charges for the period of one month all as directed by Engr-in-Charge. The Quoted rates shall to be included for the following :- (a) As the above work is required to be carried out for repair/maint of cooling appliances entire AF Stn Jodhpur hence complaints of the 'unserviceable equipment's' (ACs) to be handed over daily basis for different units locations and repairs to be carried out on the same day or next day or as directed by Engr-in-Charge. (b) The contractor shall depute adequate AC mechanic and helper (As per the complaint) with all connected tools on daily basis with suitable vehicle arrangement to repairs and attend the complaints in various units under AOR of GE (AF) Jodhpur and manage all spares included in this CA in advance or as directed by Engr-in-Charge. (c) Non attending the complaints with in 48 hrs Rs 200/- per day per complaints shall be recovered.
Material & labour for WATER JET servicing of SPLIT TYPE AC's of 1.5/2.0 Tonne capacity (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top cover outdoor top cover from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge. (Note: The contractor shall at his own cost arrange water for servicing purpose.)
Material & labour for WATER JET servicing of WINDOW TYPE AC's of 1.5/2.0 Tonne capacity (complete unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor & outdoor cover from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge. (Note: The contractor shall at his own cost arrange water for servicing purpose.)
M&L for shifting of spilt type AC of capacity 1.5/2TR of any make by opening the indoor and outdoor unit complete with accessories and fittings including filling of drilled hole of wall using high quality plaster and transporting the AC to the site where it is to be installed, installing the AC at site in and including making necessary drilling in wall making electrical connections indoor/outdoor unit and checking/testing of all parts for its serviceability, and oilling/greasing of motors, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete unit including testing for smooth functioning complete all as specified & directed by Engineer-in-charge.
M&L for removing the condenser fan motor from split type A/C of 1.5 TR capacity, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with 'E' class varnish, including replacement of gun metal bush, side rubber packing and refixing of motor in original position with new washer nuts & bolts complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
M&L for removing the condenser fan motor from split type A/C of 2 TR capacity, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with 'E' class varnish, including replacement of gun metal bush, side rubber packing and refixing of motor in original position with new washer nuts & bolts complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
Material & labour for WATER JET servicing of CASSET TYPE AC's/DUCTABLE AC's of 2.5/4/5.5 Tonne capacity (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top cover outdoor top cover from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge. (Note: The contractor shall at his own cost arrange water for servicing purpose.)
M&L for removing the condenser fan motor from window type A/C of 2/1.5 TR capacity, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with 'E' class varnish, including replacement of gun metal bush, side rubber packing and refixing of motor in original position with new washer nuts & bolts complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair blower fan motor of capacity 1/30 or 1/20 HP copper wound suitable for split type AC1.5 TR, AC/DC complete including testing commissioning complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair blower fan motor of capacity 1/30 or 1/20 HP copper wound suitable for split type AC 2 TR, AC/DC complete including testing commissioning complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F running capacitor(oil type), 45 MFD suitable for A/C of capacity 1.5 TR complete all as specified & directed by Engineer-in-charge. Make-Epcos/Havells/CG
S&F starting capacitor (oil type), 100-120 MFD suitable for A/C of capacity 1.5 TR complete all as specified & directed by Engineer-in-charge. Make-Epcos/Havells/CG
S&F in repair, drain out pipe of split AC of PVC, heavy duty of 15 mm dia and 1.5 mm wall thickness complete with fittings,spacer and saddles etc complete all as specified & directed by Engineer-in-charge.
S&F in repair, plastic fan blade suitable for window type AC 1.5/2 TR capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair, plastic fan blower of split type AC 1.5/2 TR capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair, relay suitable for window type AC 1.5 /2.00 TR capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair, over load protector suitable for window type AC 1.5 /2.00 TR capacitiey complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repairs remote control (Micro processor) unit suitable for split type AC 1.5/2 TR capacity complete with wires of remote complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
Cutting and taking out compressor of window type AC of 1.5/2 TR and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigent gas to required level complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair, of thermostat suitable for window type AC 1.5/2 TR capacity complete all as specified & directed by Engineer-in-charge.
Cutting and taking out compressor of split type AC of 1/1.5 TR and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigent gas to required level complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
Cutting and taking out compressor of split type AC of 2TR and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigent gas to required level complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair, cooling coil suitable for split type AC of capacity 1.5/2 TR complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair, cooling coil suitable for window type AC of capacity 1.5/2 TR complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair, PCB suitable to split type AC 1.5/2 TR complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair, PCB suitable to window type AC 1.5/2 TR complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair copper tube size 1/4" of split AC having capacity 1.5/2 ton complete all as specified & directed by Engineer-in-charge.
S&F in repair copper tube size 1/2" of split AC having capacity 1.5/2 ton complete all as specified & directed by Engineer-in-charge.
S&F in repair copper tube size 3/8" of split AC having capacity 1.5/2 ton complete all as specified & directed by Engineer-in-charge.
S&F in repair insulation suitable for split AC 1.5/2 TR complete all as specified & directed by Engineer-in-charge.
Supply & charging of refrigerant gas R-22 (freon) for charging in window/split type AC of 1.5/2 TR capacity complete and checking of leakage, testing for proper functioning all as specified & directed by Engineer-in-charge. Note : Measurement of Gas cylinder to be done in the presence of Engr-in-charge.
Supply & charging of refrigerant gas R-134C (freon) for window/split type ACs of any capacity complete and checking/testing for proper functioning all as specified & directed by Engineer-in-charge. Note : Measurement of Gas cylinder to be done in the presence of Engr-in-charge.
S&F in repair, main PCB suitable to inverter split type AC 1.5/2 TR complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model.”
M&L in repair for swing motor of split AC any make any type all as per sample all as specified & directed by Engineer-in-charge.
M&L in repair for split valve of ½” dia all as per sample all as specified & directed by Engineer-in-charge.
M&L in repair for split valve of ¼” dia all as per sample all as specified & directed by Engineer-in-charge.
Shiv Shakti Enterprises
M/S SHARADA ASOCIATE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .