Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC | L1 | Accepted-AOC L1 being lowest | |
| 2 | L2₹9.9 L+₹11,280 (1.15%)Rejected-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L2 | Rejected-AOC being not lowest | |
| 3 | L3₹10.0 L+₹22,795 (2.33%)Rejected-AOC | L3 | Rejected-AOC being not lowest | |
| 4 | L4₹10.7 L+₹86,025 (8.78%)Rejected-AOC SHALABH HOUSE 490 PURANI TEHSIL ROORKEE DISTT HARIDWAR | HARIDWAR | UTTARAKHAND | 247656 | L4 | Rejected-AOC being not lowest | |
| 5 | L5₹10.8 L+₹97,590 (9.96%)Rejected-AOC | L5 | Rejected-AOC being not lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Feb 2021, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ Commander Works Engineers Hills Mall Road Dehradun Cantt Dehradun 248003
REPAIR AND REPLACEMENT HT UG CABLE AND ALLIED WORKS AT RAIWALA UNDER AGE I RAIWALA
2021_MES_412644_2
86312/RWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
AGE I Raiwala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I RAIWALA
₹40,000
Yes
13 Mar 2021
8 Feb 2021
1 Mar 2021
8 Feb 2021
27 Feb 2021
15 Feb 2021
8 Feb 2021 - 12 Feb 2021
Amount
Excavation in trenches in any type of soil and n.exc 1.5 m wide and n.exc 1.5 m in depth for poles,laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out, trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed.
Returning , filling in, any type of soil including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick, in any type of soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thickness of sand will be measured and paid.
M&L for un-reinforced precast concrete cable cover ISI Marked class HVP, type 1 with peak size 300mmx180mm x 40mm compliance with IS:5820-1970, as cable protection over sand cushioning perpandicular across the cable length wise in trenches complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregate) for coping of pole and foundation for fencing post etc,including necessary form work,finished the exposed surfaces fair with out using extra cement including necessary form work complete all as specified and directed.
M&L for cutting of road/ hard standing as required at site, not exceeding 20cm width and not exceeding 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B-1 up to the existing surface level and make good complete all as directed.
M & L for GI tube light grade with all fittings laid in trenches or fixed to pole of size 80 mm bore all as specified and directed . Make : jindal/ TATA/prakash.
Supply, laying, connecting and testing in repalcement XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty ) 11000 Volts (Earthed) grade with stranded aluminium conductor cross sectional area 95 sqmm 3 core ISI marked laid in cable duct/trenches/surface/wall complete all as specified and directed. Make :- Havells/KEI/Gloster
M&L for cable jointing kit suitable for 11 KV (E) grade cable indoor end termination, cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed. Make :DENSON/M-seal/Raychem.
M&L for cable jointing kit suitable for 11 KV (E) grade cable for outdoor end termination, cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. Make :DENSON/M-seal/Raychem.
S&F MCCB 4 Pole 50 Hz, 415V, 400Amps, breaking capacity 36 KA with adjuctable thermal magnetic release, in built instantaneaus protection, Ics=100% Icu (1sec) complete all as specified & directed.
S&F MCCB 3 Pole 50 Hz, 415V, 200Amps, breaking capacity 25/30 KA with adjuctable thermal magnetic release, in built instantaneaus protection, Ics=100% Icu (1sec) complete all as specified & directed.
S&F MCCB 3 Pole 50 Hz, 415V, 250 Amps, breaking capacity 25/30 KA with adjuctable thermal magnetic release, in built instantaneaus protection, Ics=100% Icu (1sec) complete all as specified & directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in single red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified & directed.
Supply only Fuse wire made of tin of size 20 SWG complete all as specified & directed.
Supply and fix Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specefied and as directed.
M&L for prepration of old painted surfaces after removing existing treatment of HT 11 KV pole and painting with two coats of aluminium paint over a coat of red oxide primer above 1.5m height from ground level and on all steel surface such as channels,angles,clamps,nuts and bolts and washers including 05 Nos alternative band/strips with synthetic enamel paint in black/ Yellow colour (300 mm wide each) upto 1.5m height from ground level,and numbering the poles with black synthetic enamel paint having letter of height not less than 4cm, complete all as specefied and as directed.
Supply only HT fuse wire made out of tinned copper suitable for 11 KV feeder of rating 10 amp complete all as specefied and as directed by Engg-in-charge.
Supply only ISI marked PVC insulation tape 15mmx25 Mtr complete all as specified & directed Engg-in-charge.
Supply only ISI marked PVC insulation tape 20mmx25 Mtr complete all as specified & directed Engg-in-charge.
Supply only HT tape 0.6mm thick x19 mm x 15 mtr ISI Marked complete all as specified & directed Engg-in-charge.
Supply only ISI Marked insulation tape(empire tape) of best quality insulation class A, dry, non adhensive,tensile strength not less than 38 lbs/inch 25mm x 15 mtr complete all as specified & directed by Engg-in-charge.
Supply only rubber hand glove suitable for 11 KV complete all as specified & directed by Engg-in-charge.
Supply only ISI Marked Aluminium Lugs 25/35 sqmm suitable for aluminium conductor UG cable complete all as specified & directed Engg-in-charge.
All as per srl item No 25 above but of size 50 sqmm complete all as specified & directed Engg-in-charge.
All as per srl item No 25 above but of size 70 sqmm complete all as specified & directed Engg-in-charge.
All as per srl item No 25 above but of size 95 sqmm complete all as specified & directed Engg-in-charge.
All as per srl item No 25 above but of size 120 sqmm complete all as specified & directed Engg-in-charge.
All as per srl item No 25 above but of size 150 sqmm complete all as specified & directed Engg-in-charge.
All as per srl item No 25 above but of size 185 sqmm complete all as specified & directed Engg-in-charge.
KAPOOR ELECTRICALS
Bansal Electric Works
SHALABH INDIA INDUSTRIES
KUKREJA BROTHERS
GLIBS CONSTRUCTION
M/s RP AGRAWAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .