Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.9 CrAccepted-AOC DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | ₹1.9 Cr | 1 | Accepted-AOC stands as L1 |
| 2 | 2₹2.2 Cr+₹28.9 L (15.1%)Rejected-AOC JATANBARI KARBOK GOMATI TRIPURA | ₹2.2 Cr+₹28.9 L (15.1%) | 2 | Rejected-AOC stands as L2 |
Tender Value
₹1.8 Cr
EMD Value
₹3.7 L
Closing Date
11 Mar 2024, 12:00 pmClosed
DGM, ED Manu
DGM, ED Manu, Ltv Dhalai Tripura
Construction of HT/LT and DT for providing Service connection to DTW Scheme under JJM under Ed manu ltv Dhalai TRipura
2024_POWER_48090_1
DGM/MANU/E-TENDER/23-24/08
Open Tender
Electrical Works
Turn-key
180 days
ED-Manu, LTV, Dhalai Tripura
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,000
₹3.7 L
ED-Manu, LTV , Dhalai Tripura
3 May 2024
5 Mar 2024
11 Mar 2024
5 Mar 2024
11 Mar 2024
5 Mar 2024
6 Mar 2024
Amount
Scheduled A Supply
9 mtr. long PCC Pole conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed.
8 mtr. long PCC Pole conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed.
9 mtr. long steel Pole 410:SP-32 conforming to IS:2713 (P-I & II)/1980 and latest amendment with Mild Steel Base Plate and as per TSECL’s tender specification enclosed.
8 mtr. long steel Pole 410:SP-15 conforming to IS:2713 (P-I & II)/1980 and latest amendment with Mild Steel Base Plate and as per TSECL’s tender specification enclosed.
Stay set Complete conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed.
Stay Insulator (HT) conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed.
Stay Insulator (LT) conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed.
Stay Std. wire, (7/2.50 mm) conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed.
M.S. Channel-100X50X50X6 mm, conforming to relevant IS with up-to- date amendment and as per TSECL’s tender specification enclosed .
M.S. Channel-75x40x40x6mm conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
M.S. Angel 65x65x6mm conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
M.S. Angel 50x50x6mm conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
M.S. Nuts & bolts (assorted size) conforming to relevant IS with up-to- date amendment and as per TSECL’s tender specification enclosed .
11 KV Pin Insulator (Poly) conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
11 KV Disc Insulator (Poly) conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
11 KV Disc Fittings conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
LT Shackle Insulator (3x3.5)" size conforming to relevant IS with up-to- date amendment and as per TSECL’s tender specification enclosed .
Lt Straps, Nuts & Bolts conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
A.C.S.R-6/1/2.59 mm weasel conductor conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
G.I. wire-8 SWG conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
11 KV G.O. Switch, 3-Phase conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
11 KV D.O. Fuse, 3-Phase conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
11 KV L.A. polymer(9 KV, 5 KA L.A) conforming to relevant IS with up-to date amendment and as per TSECL’s tender specification enclosed
100 A Cut-Out conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
200 A Cut-Out conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
PVC Cable-70 sq.mm conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
PVC Cable-16 sq.mm conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
Danger plate conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
Barbed wire conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
60 kg Salt & 55 kg Charcoal for earthing (1 pit)
GI pipe 40mm dia 2.5 Mtr long (Make - TATA / JINDAL) conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed
Wooden plank
Aluminium Lugs - 95 sq.mm conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
PVC Pipe 1" Size
Stay Clamp of MS Flat (50x6mmm)
Bracket Clamp of MS Flat (50x6mmm)
SCHeduled B DISMENTLING
9.00 Mtr. Long PCC Pole
9.00 Mtr. Long steel Pole
8 mtr. long PCC Pole (highly Inclined)
SP Top X-arm of 0.3 Mtr. Long MS Channel of Size 75x40x40x6mm
SP bottom X-arm of 1.2 Mtr. Long MS Channel of Size 75x40x40x6mm
SP Gaurd X-arm of 1.6 Mtr. Long MS Angle of Size 65x65x6 mm.
DP Top X-arm of 2.2 Mtr. Long MS Channel of Size 75x40x40x6mm.
DP Top Guard X-arm of 2.5 Mtr. Long MS Channel of Size 65x65x6 mm.
11KV Polymer Disc insulator with fittings
11KV Polymetric Pin Insulator
Stay Set Complete
A.C.S.R. (6/1/2.59 mm)
GI Wire (8SWG)
Cradle Guard
4-wire LT bracket(01.10mtr.long of M.S.Angle-50X50X6mm)
2-wire LT bracket(0.6 mtr.long of M.S.Angle-50X50X6mm)
LT Shackle Insulator(3X3.5)" size with straps, Nuts & Bolt
SCHEDULED C ERECTION
Installation / positioning of 11/0.430 KV , 3-phase 63 KVA of distribution transformer on pole with necessary connection and fitting fixing of all allied assessories components as required for making complete in all respect for energizing .
Installation / positioning of 11/0.430 KV , 3-phase 100 KVA of distribution transformer on pole with necessary connection and fitting fixing of all allied assessories components as required for making complete in all respect for energizing .
9 mtrs length of PCC pole at any kind of soil upto a depth of 1/6th of pole height , i/c excavation of earth , refilling the pit with soil upto the ground level, ramming and making complete in all respect
9 mtrs length of Steel pole at any kind of soil upto a depth of 1/6th of pole height , i/c excavation of earth , refilling the pit with soil upto the ground level, ramming and making complete in all respect .
8 mtrs length of Steel pole at any kind of soil upto a depth of 1/6th of pole height , i/c excavation of earth , refilling the pit with soil upto the ground level, ramming and making complete in all respect i/c Hand-cart carriage & mannual carriage with necessary loading & unloading.
8 mtrs length of PCC pole at any kind of soil upto a depth of 1/6th of pole height , i/c excavation of earth , refilling the pit with soil upto the ground level, ramming and making complete in all respect i/c Hand-cart carriage & mannual carriage with necessary loading & unloading.
2.8 Mtr. Long MS Channel of Size 100x50x50x6mm for DT & Disc support
0.8 Mtr. Long MS Channel of Size 100x50x50x6mm for DT support
2.8 Mtr. Long MS Channel of Size 75x50x50x6mm for GO & DO & LA i/c lineGO & DOF
2.8 Mtr. Long MS Channel of Size 65x65x6mm SS
SP Top X-arm of 0.3 Mtr. Long MS Channel of Size 75x40x40x6mm
SP bottom X-arm of 1.2 Mtr. Long MS Channel of Size 75x40x40x6mm
SP Guard X-arm of 1.6 Mtr. Long MS Angle of Size 65x65x6 mm.
DP Top X-arm of 1.7 Mtr. Long MS Channel of Size 75x40x40x6mm.
DP bottom X-arm of 2.2 Mtr. Long MS Channel of Size 75x40x40x6mm.
DP Guard X-arm of 2.5 Mtr. Long MS Angle of Size 65x65x6 mm.
LT Shackle Insulator (3x3.5)" size
4-wire LT bracket(01.10mtr.long of M.S.Angle-50X50X6mm)
Laying & stringing of 1 km (single conductor ) ACSR 6/1/2.59mm dia weasel i/c hoisting & binding etc. complete as reqd.
Laying & stringing of 1 km (single conductor ) 8 SWG GI wire i/c hoisting & binding etc. complete as reqd.
Stay Set Complete
11KV Polymer Disc insulator with fittings
11KV Polymetric Pin Insulator
11 KV G.O.S. 3-phase
11 KV D.O.F. 3-phase
11 KV L.A. (polymer)
Cradle Guard
Barbed wire (anti-climbing device) per pole
Danger plate
Providing three phase Service Connection
Construction of Sub-station Fencing with barbed wire, errection supply & errection of barbed wire fencing of MS Angle ( 6Nos. 65x65x6mm & 4Nos . 50x50x6 mm)& provision of gate ( to be fabricated by 35x35x6 mm M.S. Angle-20x6mm M.S. Flat ) fixed with supports of fencing belted at top by 35x35x6 mm M.S. Anglethrough out with provision of hings & locking arragement etc. as per approved design & drawing .
Sub-Station Name plate in/c supply as directed by Engg- in -charge.
Earthing with GI pipe 2.5mtr long and 40 mm dia, including excavation, refilling with alternate layer of salt and charcoal as per drawing (excluding supply of GI pipe, salt and charcoal, GI wire, Nuts & bolts etc. As required).
Carring of the following
Carriage of 63 KVA transformer / 100 KVA transformer from A.D.Nagar, Agartala Electrical Store yard to work site by mechanical transport including Loading, Un- loading & Stacking etc. as required.
63 KVA transformer
100 KVA transformer
Carriage of Store Materials from A.D.Nagar, Agartala Electrical Store yard to work site by mechanical transport including Loading, Un- loading & Stacking etc. as required. Like Meter and ETC
9 Mtr Long PCC Pole
8 Mtr Long PCC Pole
9 Mtr Long Steel Pole
8 Mtr Long Steel Pole
Fabrication of all X-Arm by M.S Angle, MS Channel , M.S. flats etc.
Survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of Project Manager
Stretening of 9 Mtr Long PCC Pole
Re-stringing of conductor including binding, hoisting, jumpering etc as required.
A.C.S.R-(6/1/2.59 mm)
Re-adjustment of stayset complete without dismentalling turn buckle.
Jungle cutting
Grouting of Steel pole C.C. work 1:2:4 (1 Cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) 0.273 cum per pole in/c supply of all materials as required.
RATAN PAUL
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .